360 KARJALAINEN PP et al. ORIGINAL ARTICLE Circulation Journal Oicial Journal of the Japanese Circulation Society http://www.j-circ.or.jp Cardiovascular Intervention Early Neointimal Coverage and Vasodilator Response Following Biodegradable Polymer Sirolimus-Eluting vs. Durable Polymer Zotarolimus-Eluting Stents in Patients With Acute Coronary Syndrome – HATTRICK-OCT Trial – Pasi P. Karjalainen, MD, PhD; Ville Varho, MD; Wail Nammas, MD, PhD; Jussi Mikkelsson, MD, PhD; Mikko Pietilä, MD, PhD; Antti Ylitalo, MD, PhD; Juhani K.E. Airaksinen, MD, PhD; Jussi Sia, MD, PhD; Kai Nyman, MD, PhD; Fausto Biancari, MD, PhD; Tuomas Kiviniemi, MD, PhD Background: Patients at high bleeding risk would benefit from a shorter dual antiplatelet therapy after PCI. Compared to first-generation devices, the design of newer generation drug-eluting stents may facilitate more rapid anatomical and functional healing of stented vessel based on thinner stent platforms, biodegradable/biocompatible polymers and rapid drug elution. Methods and Results: Forty-four non-diabetic patients with acute coronary syndrome (ACS) and culprit lesion in the LAD were randomized to receive either biodegradable polymer sirolimus-eluting stent (BP-SES) or durable polymer zotarolimus-eluting stent (DP-ZES). Neointimal strut coverage was examined using optical coherence tomography, and vasodilator response on invasive thermodilution-derived coronary flow reserve (CFR) at 3-month follow-up. The primary endpoints were percent uncovered struts and CFR. A total of 425 cross-sections (4,897 struts) were analyzed in the BP-SES group, and 425 cross-sections (5,467 struts) in the DP-ZES group. The percent uncovered struts was lower in the BP-SES group compared with the DP-ZES group, both at strut level (3.9% vs. 8.9%, respectively, P<0.001), and stent level (3.9±3.2% vs. 8.9±6.9%, respectively, P=0.019). No significant difference was found between the 2 groups regarding CFR (3.0±1.3 vs. 3.2±1.0, respectively, P>0.05). Conclusions: In non-diabetic patients with ACS, BP-SES provided slightly better stent strut coverage at 3 months compared with DP-ZES, but neither stent was fully covered. No difference in vasodilator response was seen. (Circ J 2015; 79: 360 – 367) Key Words: Biodegradable polymer; Coronary flow reserve; Optical coherence tomography; Sirolimus-eluting stent; Zotarolimus-eluting stent ecent reports suggest a paradigm shift in the occurrence of stent thrombosis (ST) as evidenced by lower event rates in patients treated with newer generation drugeluting stents (DES) compared to bare metal stents (BMS) or irst-generation DES.1 Incomplete neointimal coverage over stent struts has been suggested as a potential substrate for late ST in histopathological studies,2 as well as in an observational case-control setting using optical coherence tomography (OCT) in vivo.3 Durable polymer is a possible stimulus for vessel wall R inlammatory and hypersensitivity reaction leading to incomplete endothelialization following DES implantation. Localized hypersensitivity reaction has been demonstrated in the vessel wall at autopsy, and in thrombus aspirates, from patients with very late ST following irst-generation DES.4,5 Newer generation DES have thinner stent platforms, biodegradable/biocompatible polymers and rapid drug elution compared to irst-generation devices. The frequency of uncovered struts was reported lower with biodegradable polymer biolim- Received September 10, 2014; revised manuscript received November 3, 2014; accepted November 12, 2014; released online December 15, 2014 Time for primary review: 22 days Heart Center, Satakunta Central Hospital, Pori (P.P.K., J.M., A.Y.); Heart Center, Turku University Hospital and University of Turku, Turku (V.V., W.N., M.P., J.K.E.A., T.K.); Department of Cardiology, Central Ostrobothnia Central Hospital, Kokkola (J.S.); Department of Medicine, Central Finland Central Hospital, Jyväskylä (K.N.); and Department of Surgery, Oulu University Hospital, Oulu (F.B.), Finland The irst two authors contributed equally (P.P.K., V.V.). Mailing address: Pasi P. Karjalainen, MD, PhD, Department of Cardiology, Satakunta Central Hospital, Sairaalantie 3, FIN-28100, Pori, Finland. E-mail: pasi.karjalainen@satshp.i ISSN-1346-9843 doi: 10.1253/circj.CJ-14-1000 All rights are reserved to the Japanese Circulation Society. For permissions, please e-mail: cj@j-circ.or.jp Circulation Journal Vol.79, February 2015 HATTRICK-OCT Trial 361 Figure 1. Flow chart of the HATTRICK-OCT trial. us-eluting stents compared with durable polymer sirolimuseluting stents (SES), as demonstrated on OCT at 9-month follow-up,6 but not compared with durable polymer everolimus-eluting stents (DP-EES).7 In a bench-top study, the biocompatible BioLinx polymer did not induce activated monocyte adhesion.8 BioLinx polymer-coated zotarolimus-eluting stent (ZES) was associated with low rates of uncovered and malapposed struts on OCT at 13 months.9 Earlier reports have also raised concerns about local epicardial vasomotor dysfunction associated with DES 6 months or later after implantation.10,11 In this prospective randomized trial, we combined the anatomical and functional healing assessment by exploring neointimal strut coverage and vasodilator response 3 months following biodegradable polymer SES (BP-SES) vs. BioLinx durable polymer ZES (DP-ZES) implantation in non-diabetic patients presenting with acute coronary syndrome (ACS). Methods Patient Selection and Study Design The Healing AT ThRee months after percutaneous coronary Intervention for ACS (HATTRICK-OCT) trial was a prospective multicenter single-blinded randomized controlled trial, with the chief aim of comparing neointimal coverage and vasodilator response 3 months following the implantation of BP-SES vs. DP-ZES in non-diabetic patients presenting with ACS. From June 2011 to July 2012, we enrolled 46 patients aged >18 years, presenting with ACS, with a signiicant (≥50% diameter ste- nosis) de novo lesion in the left anterior descending coronary artery. Consort low chart is presented in Figure 1. The main exclusion criteria were diabetes mellitus (presumed microcirculatory dysfunction), unprotected left main disease, ostial or bifurcation lesion, multi-vessel disease, a second de novo stenosis ≥50% in the stented vessel, intolerance to the study medications, planned surgery within 12 months of the index procedure, and life expectancy <12 months. The HATTRICK-OCT trial was conducted in 4 referral centers. Patients were randomly assigned (1:1) to receive either BP-SES or DP-ZES. Computer-generated randomization was implemented using a closed-envelope system stratiied by center. Study investigators were by necessity aware of treatment allocation, but patients and those who performed data management and analysis were blinded. Devices The BP-SES (Orsiro; Biotronik, Bülach, Switzerland) has a stent platform based on the Pro-Kinetic Energy BMS with a helicoidal design coated with passive and active coating layers. It is a tubular thin-strut balloon-expandable stent, made of L-605 cobalt-chromium alloy. The stent surface is completely coated with a layer of silicon carbide (PROBIO®) that acts as a diffusion barrier reducing ion release. The active coating layer (BIOlute) consists of high-molecular-weight poly-l-lactic acid that completely disintegrates into carbon dioxide and water. It covers the whole stent surface with an abluminal thickness of 7.5 µm, and a luminal thickness of 3.5 µm. The sirolimus Circulation Journal Vol.79, February 2015 362 KARJALAINEN PP et al. concentration is 1.4 µg/mm2 of the stent surface area, designed to achieve complete drug release in approximately 100 days. The thickness of the coated strut is 71 µm for stents with a nominal diameter ≤3 mm, and 91 µm for larger sizes. DP-ZES (Resolute Integrity; Medtronic Cardiovascular, Santa Rosa, CA, USA) is a DES that contains zotarolimus at a dose of 1.6 µg/mm2 of stent surface area; 85% of the drug is eluted in the irst 60 days; the drug is completely eluted at 180 days. It is coated with BioLinx polymer, composed of 3 different polymers: the hydrophobic C10 acts as a drug reservoir for slow and sustained release; the hydrophilic polyvinyl-pyrrolidinone serves biocompatibility; and C19 contains both hydrophilic and hydrophobic components. The thickness of the coated strut is 97 µm. Pharmacological Interventions Patients already maintained on aspirin received no additional aspirin loading. Aspirin-naïve patients received a loading dose of 250 mg orally or 250–500 mg i.v., and continued at a daily dose of 75–150 mg indeinitely. Oral clopidogrel was initiated at a loading dose of at least 300 mg before or immediately after the procedure, and continued at a daily dose of 75 mg. As per protocol, patients in either group were prescribed oral clopidogrel for a minimum of 6 months, and thereafter, for extended periods (maximum 12 months) at the operator’s discretion. During the procedure, low-molecular-weight heparin or unfractionated heparin was administered i.v. in the standard dosage. Use of peri-procedural glycoprotein IIb/IIIa inhibitors or bivalirudin was at the operator’s discretion. Ethics This study is part of a wider protocol in progress to assess thrombotic and bleeding complications of cardiac procedures in Finland.12–17 The study was initiated and designed by the investigators and conducted according to the ethics guidelines of the 1964 Declaration of Helsinki, as revised in 2002. No industry representatives were involved in the study execution, analysis or reporting. Informed written consent was obtained from every patient after explanation of the study protocol. The protocol was approved by the Ethics Committees of the coordinating center, Turku University Hospital, and the other participating hospitals. The HATTRICK-OCT trial is registered with ClinicalTrials.gov, number NCT01391871. OCT Image Acquisition OCT images were obtained 3 months after the index procedure, immediately after follow-up angiography, with the C7Xr frequency-domain system (LightLab Imaging, Westford, MA, USA), using the non-occlusive technique via radial or femoral approach. A 0.014-inch guidewire was introduced into the vessel using a 6-F guiding catheter. An imaging catheter (Dragonly; LightLab Imaging) was positioned distal to the stent, and automated motorized pullback was performed at 20 mm/s during lush of 4–6 ml/s iso-osmolar contrast. A segment length of 54 mm was visualized, and images were stored digitally for subsequent analysis. Image Analysis Ofline OCT analysis was performed independently by 2 investigators blinded to patient characteristics and to the stent used. Proprietary software (LightLab Imaging) was used to analyze cross-sections at 1-mm intervals (every 5 frames) within the stented segment. In each cross-section, the number of struts was counted. Struts were classiied as uncovered if any part of the strut was visibly exposed to the lumen, or covered if a layer of tissue was visible all over the relecting surfaces. The percent uncovered struts was calculated as the number of uncovered struts as a percentage of all analyzed struts. In covered struts, neointimal hyperplasia (NIH) thickness was measured from the strut marker to the endoluminal edge of the tissue coverage, following a straight line connecting the strut marker with the center of gravity of the vessel.14 Stent cross-sectional area (CSA) and lumen CSA were traced semi-automatically. NIH area was calculated by subtracting lumen CSA from stent CSA. Percent NIH area was calculated by dividing the NIH area by the stent CSA, multiplied by 100. Apposition was assessed by measuring the distance between the strut marker and the lumen contour following a straight line connecting this marker with the center of gravity of the vessel. A margin of 18 µm was added as a correction for half the blooming. Struts with distance to lumen contour greater than the sum of strut thickness+polymer thickness+18 µm were considered malapposed. Given a coated strut thickness of 71 µm, we adopted a malapposition threshold of 90 µm for the BP-SES (110 µm for stents >3.0 mm in diameter). Similarly, given a coated strut thickness of 97 µm for the DP-ZES, we adopted a threshold of 115 µm. Struts located at the ostium of a side branch were excluded from the analysis. Thrombus was deined as an irregular high- or low-backscattering (red or white thrombus) mass protruding into the lumen discontinuous from the surface. Hemodynamic Measurements Patients were instructed to avoid heavy meals, caffeine, alcohol and tobacco for 12 h before the study. Coronary low reserve (CFR), fractional low reserve (FFR) and index of microcirculatory resistance (IMR) were measured as follows. A bolus of i.c. nitroglycerin (0.2 mg) was administered at the onset of the procedure, and repeated before baseline and hyperemia assessments. A coronary 0.014-inch pressure wire (Certus®; St. Jude Medical, MN, USA) was used. After calibration, the pressure wire was advanced to the tip of the guiding catheter for equalization of pressure and temperature signals, and then positioned distal to the stent approximately at two-thirds of the length of the artery. Care was taken to maintain the guiding catheter and sensor in position throughout all measurements. The sensor was used to obtain thermodilution curves and distal coronary pressure. The resting mean transit time was determined by 3 injections of 3 ml room-temperature saline.18 Hyperemia was induced by i.v. infusion of adenosine (140 μg · kg–1 · min–1). Steady-state maximum hyperemia was conirmed by minor drop of the aortic pressure and subjective sensation of adenosine effects. Measurements were obtained after at least 1 min from the onset of infusion. The hyperemic mean transit time was assessed using 3 injections of 3 ml room-temperature saline. In the case of large luctuation (>20% variation) of hyperemic or basal mean transit time, measurement was repeated. CFR was calculated as a ratio of baseline to hyperemic mean transit time. Simultaneous measurement of the mean aortic pressure (Pa) and the mean distal coronary pressure (Pd) were also performed at maximum hyperemia to calculate FFR. IMR was calculated as the distal coronary pressure at maximum hyperemia divided by the inverse of the hyperemic mean transit time. Statistical Analysis The primary endpoint was the percent of uncovered struts in BP-SES compared with DP-ZES at 3-month follow-up. Sample size was calculated using 2 methods. We assumed that an average of 150 struts per patient would be analyzed, and therefore we estimated that inclusion of 22 patients in each group would show 5% difference in the percent uncovered struts between BP-SES and DP-ZES (power of 80%, 2-sided type I error of 0.05). We also calculated a sample size of 22 patients/ Circulation Journal Vol.79, February 2015 HATTRICK-OCT Trial 363 Table 1. Baseline Subject Characteristics BP-SES group (n=22) DP-ZES group (n=22) P-value Age (years) 62.5±9.7 62.0±12.1 0.87 Male 18 (81.1) 17 (77.3) 0.72 Hypertension 8 (36.4) 6 (27.3) 0.75 Hypercholesterolemia 7 (31.8) 4 (18.2) 0.49 Current smoking 5 (22.7) 8 (36.4) 0.51 Prior myocardial infarction 1 (4.5) 1 (4.5) 1.0 Prior PCI/CABG 1 (4.5) 0 1.0 Variable Risk factors Medical history Medications at discharge Aspirin 22 (100) 22 (100) 1.0 Clopidogrel 22 (100) 22 (100)† 1.0 ACEI/ARB 18 (81.8) 15 (68.2) 0.49 β-blockers 21 (95.5) 22 (100) 1.0 1 (4.5) 0 1.0 22 (100) 22 (100) 1.0 VKA Statins Indication for PCI Unstable angina 1 (4.5) 3 (13.6) 0.61 NSTEMI 9 (40.9) 8 (36.4) 1.0 STEMI 12 (54.5) Stent diameter (mm) 11 (50) 1.0 3.2±0.3 3.2±0.3 0.71 18.0±3.4 17.5±3.2 0.65 2 (9.1) 1 (4.5) 1.0 A 3 (15.8) 2 (11.1) B1 10 (52.6) 12 (66.7) B2 6 (31.6) 3 (16.7) C 0 1 (5.6) Pre-procedural TIMI flow grade 1.7±1.4 1.9±1.2 0.73 Culprit lesion related thrombus 12 (60.0) 6 (30.0) 0.111 9 (42.9) 6 (27.3) 0.347 Pre-dilatation 17 (77.3) 19 (82.6) 0.722 Post-dilatation 9 (40.9) 18 (78.3) 0.016 13.2±2.6 13.1±3.3 0.953 3.0±0.0 3.0±0.2 0.15 Stent length (mm) Two overlapping stents Lesion type 0.50 Aspiration thrombectomy Maximal expansion pressure Post-procedural TIMI flow grade Data given as mean ± SD or n (%). †One patient treated with prasugrel. ACEI, angiotensin-converting enzyme inhibitor; ARB, angiotensin II receptor blocker; BP-SES, biodegradable polymer sirolimus-eluting stent; CABG, coronary artery bypass grafting; DP-ZES, durable polymer zotarolimus-eluting stent; NSTEMI, non-ST-elevation myocardial infarction; PCI, percutaneous coronary intervention; STEMI, ST-elevation myocardial infarction; TIMI, Thrombolysis In Myocardial Infarction; VKA, vitamin K antagonist. group using an effect size of 5% and expected SD of 5% in stent-level analysis (power of 80%, 2-sided type I error of 0.05).19 Co-primary endpoint was CFR at 3-month follow-up. Continuous variables were tested for normality with KolmogorovSmirnov and Shapiro-Wilk tests and reported as mean ± SD or as median and interquartile range (IQR) where appropriate. Fisher exact test, independent samples t-test, Mann-Whitney U-test and Spearman’s test were used for univariate analysis. Inter-observer variability was assessed by evaluating 50 random cross-sections by 2 independent investigators. Pooled analysis of measurements was performed in order to account for clustering, in view of the large number of measurements obtained on OCT, and hence to get a better estimation of the proportion of uncovered struts, malapposed struts, and NIH thickness. Because heterogeneity was anticipated and conirmed among observational studies, pooled analysis was per- formed using a random effects model (DerSimonian-Laird). Meta-regression was used to estimate the difference between the study groups. All statistical analysis was 2-sided at the 5% signiicance level using SPSS v. 16.0.1 (SPSS, Chicago, IL, USA) and Open Meta-analyst (http://www.cebm.brown.edu/ open_meta). Results Baseline Characteristics Forty-six non-diabetic patients with ACS were enrolled: 23 received BP-SES, and 23 received DP-ZES. Two patients withdrew consent (1 in each group), thus 22 patients in either group were available for analysis. Angiography was performed at median follow-up of 93 days (IQR, 23 days) following the index procedure in the BP-SES group, vs. 98 days (IQR, 20 days) in Circulation Journal Vol.79, February 2015 364 KARJALAINEN PP et al. Table 2. Optical Coherence Tomography Variable BP-SES group (n=22) DP-ZES group (n=22) P-value Cross-sectional analysis No. cross-sections analyzed Struts per cross-section 425 425 1.0 11.5±0.66 12.9±1.2 <0.001 Stent area (mm2) 6.8±1.6 7.5±1.7 0.09 Lumen area (mm2) 6.5 [2.2] 7.1 [2.6] 0.06 NIH area (μm2) 380 [410] 460 [550] 0.11 % NIH area 5.7 [5.9] 5.7 [7.6] 0.69 0.13 Strut-level analysis Total no. struts analyzed 4,897 5,467 NIH thickness (μm) 69.1±58.2 76.5±82.9 0.15 Uncovered struts 189 (3.9) 495 (8.9) <0.001 Malapposed struts 101 (2.1) 292 (5.3) <0.001 3.9±3.2 8.9±6.9 0.019 Stent-level analysis % Uncovered struts Stents with >5% uncovered struts % Malapposed struts Intra-stent thrombus 7 (31.8) 14 (63.6) 0.069 2.2±3.7 4.3±9.5 0.33 2 (9.1) 1 (4.5) 1.0 Data given as mean ± SD, median [IQR], or n (%). NIH, neointimal hyperplasia. Other abbreviations as in Table 1. Figure 2. Evaluation of the study stents on optical coherence tomography at 3-month follow-up. (A,B) stent struts well covered with neointima (arrows). (C,D) uncovered struts. Circulation Journal Vol.79, February 2015 HATTRICK-OCT Trial 365 Table 3. Invasive Hemodynamics BP-SES group (n=18) DP-ZES group (n=16) P-value Fractional flow reserve 0.87±0.07 0.87±0.06 0.93 Coronary flow reserve 3.0±1.3 3.2±1.0 0.56 Coronary flow reserve <2.5 8 (44.4) 2 (12.5) 0.06 19.2±8.1 22.7±13.0 0.32 Variable Index of microcirculatory resistance Data given as mean ± SD or n (%). Abbreviations as in Table 1. the DP-ZES group (P=0.65). Clinical and procedural characteristics (Table 1) were balanced between the 2 groups (P>0.05 for all), apart from occurrence of post-dilation: 9 (40.9%) vs. 18 (78.3%) in BP-SES and DP-ZES, respectively (P=0.016). Culprit lesion-related thrombus was seen initially in 12 (54.5%) vs. 6 (27.3%), in the BP-SES vs. DP-ZES groups, respectively (P=0.11). OCT Measurements OCT image acquisition was successful in all patients, and no OCT procedure-related complications were observed. We analyzed 4,897 struts in 425 cross-sections of BP-SES and 5,467 struts in 425 cross-sections of DP-ZES (Table 2). The percent of uncovered struts was signiicantly lower in the BP-SES compared with the DP-ZES group, both at strut level (3.9% vs. 8.9%, respectively, P<0.001), and at stent level (3.9±3.2% vs. 8.9±6.9%, respectively, P=0.019; Figure 2). Moreover, the frequency of malapposed struts was signiicantly lower in the BP-SES group at strut level (2.1% vs. 5.3%, respectively, P<0.001), but not at stent level (2.2±3.7% vs. 4.3±9.5%, respectively, P=0.33). Mean NIH thickness, NIH area, and percent NIH area, however, were similar between the 2 groups (P>0.05 for all). Thrombi were detected in 2 stents in the BP-SES group vs. 1 stent in the DP-ZES group (P=1.0). Inter-observer variability for measurement of NIH thickness was 6±9 µm. In addition, the measurements of strut apposition and coverage were highly reproducible. Pooled analysis showed that the proportion of uncovered struts in the overall series was 5.6% (95% CI: 4.6–6.5%), with signiicant heterogeneity between the evaluated struts (I2=93%). The pooled proportion of uncovered struts was 3.3% (95% CI: 2.3–4.2%, I2=82%) for BP-SES, and 8.2% (95% CI: 6.4–9.9%, I2=95%) for DP-ZES (P<0.0001). The pooled proportion of malapposed struts was 1.5% (95% CI: 0.9–2.0%, I2=82%) for BP-SES, and 2.5% (95% CI: 1.7–3.3%, I2=95%) for DP-ZES, (P=0.479). The pooled mean NIH thickness was 68.2 µm (95% CI: 59.6–76.9%, I2=98%) for BP-SES, and 74.2 µm (95% CI: 62.7–85.7, I2=98%) for DP-ZES, (P=0.465). Hemodynamic Measurements Patients with FFR<0.8 were excluded from the CFR data analysis (4 and 3 patients in the BP-SES and DP-ZES groups, respectively). No statistically signiicant differences were found between the 2 groups regarding CFR, FFR and IMR (P>0.05 for all; Table 3). Left ventricular ejection fraction was similar between the groups (65.4±8.0% vs. 62.0±12.2% for BP-SES and DP-ZES, respectively). Discussion The current HATTRICK-OCT trial has shown that in nondiabetic patients presenting with ACS, the percent of uncovered stent struts on OCT was slightly lower for BP-SES compared with DP-ZES at 3-month follow-up. Neither of the stents, however, was fully covered at 3 month follow-up. Vasodilator response assessed using CFR, FFR and IMR was similar between the 2 groups. This is the irst study to use a combination of OCT-derived anatomical as well as pressure wire-based functional healing assessment after stent implantation. Rationale for the early 3-month time frame was to gather up-to-date information on newer generation DES healing properties in patients treated for ACS: a condition often associated with delayed healing pattern. This information is important especially when shorter dual antiplatelet therapy (DAPT) needs to be considered for patients at high risk for bleeding complications. HATTRICK-OCT provides evidence that vascular healing was not complete at 3 months follow-up with these new-generation stent devices, as evidenced by the minor proportion of uncovered stent struts and abnormal vasodilator function in some patients. It is currently not known what would be the suficient OCT-derived level of strut coverage (and lack of malapposition) to be able to safely discontinue DAPT without risk of ST. Nevertheless, recent clinical data suggest that patients who interrupt or discontinue DAPT medication between 1 and 12 months after DP-ZES implantation are considered at low risk and showed no increased risk for ST compared with those on continuous DAPT until 12 months.20 On this basis, it seems that BP-SES could have at least as low as or lower ST risk compared with DP-ZES, but this needs to be veriied in prospective clinical trial. BP-SES: Clinical Perspective Previously, SES demonstrated evidence of greater eficacy for reduction of restenosis and late lumen loss (LLL), compared with other irst-generation DES.21 In one of the early attempts to use BP-SES, TIVOLI stent (Essen Technology, Beijing, China) was compared with a DP-ZES (Endeavor’ Medtronic Cardiovascular, USA) in a non-randomized fashion.22 In-stent LLL and binary restenosis at 8-month follow-up were signiicantly lower with the BP-SES compared with the DP-ZES; at 2-year follow-up, target lesion revascularization was signiicantly lower with the BP-SES.22 Another non-randomized study showed similar in-stent LLL in patients who received BP-SES (EXCELLTM; JW Medical, Shandong, China) and DP-SES (0.14 vs. 0.12 mm, respectively, P=0.629) at 9-month followup.23 An angioscopy study on DP-ZES reported struts fully embedded in neointima at 4 months.24 A irst-in-man report of a novel BP-SES with L-605 cobalt-chromium stent platform (FIREHAWK®; MicroPort Medical, Shanghai, China) implanted in single de novo coronary lesions demonstrated an in-stent LLL of 0.13 mm at 4-month follow-up.25 And, similar to the present study, on OCT at 4 months, a frequency of uncovered struts of 3.8% was noted (3.9% in the present study), but the prevalence of malapposed struts was much lower (0.1% vs. 2.6% in the present study).25 The exclusive enrolment of patients with ACS in the present study may partly explain the Circulation Journal Vol.79, February 2015 366 KARJALAINEN PP et al. higher prevalence of malapposed struts at a similar time point. The frequent use of balloon post-dilation in that study (52.4%) does not account for the difference in malapposition, because the rates of post-dilation in the present study were 40.9% and 78.3% between BP-SES and DP-ZES, respectively. Interestingly, malapposition was more frequent in DP-ZES, despite a higher rate of post-dilatation. The malapposition at 3 months might be explained by positive remodelling of the vessel wall as a response to the drug polymer in DP-ZES, which is also supported by the statistically insigniicant trend towards larger lumen CSA in DP-ZES despite equal baseline lumen diameters. Unfortunately, the absence of baseline OCT assessment limits the discrimination between persistent acute malapposition and late acquired malapposition. Finally, the BIOFLOW-I was a irst-in-man study evaluating the eficacy and safety of the Orsiro BP-SES in 30 patients with single de novo native coronary lesions.26 Angiographic in-stent LLL was 0.05±0.22 mm at 9-month follow-up; at 12 months, the cumulative incidence of device-oriented major adverse cardiovascular events was 10%; no ST was observed. The current study in non-diabetic patients with ACS demonstrated better OCT-detected neointimal strut coverage associated with the Orsiro BP-SES compared with DP-ZES at 3 months. Vasodilator Function Impaired vasodilator response has been reported after DES implantation using i.c. acetylcholine infusion, rapid atrial pacing, physical exercise, and adenosine, as vasodilator stimuli.8,9,27 CFR was adopted as an indicator of functional healing because it was recently shown to predict outcome when added to standard evaluation, in unselected patient populations, as well as in patients with ACS.14,28,29 We used a coronary pressure wire (Certus®) for the functional healing assessment because it allows simultaneous measurement of CFR, IMR and FFR. Whereas FFR measures the pressure drop across an epicardial vessel and IMR the vasodilator capacity of the microcirculation, CFR relects coronary low through both the epicardial arteries and the microcirculation. Reduced CFR can be due to either stenosis in epicardial arteries or combined dysfunction of the coronary microcirculation and vascular endothelium.30 Previously, lower CFR was detected in patients with DP-EES compared with titanium-nitride-oxide-coated stents at 10-month followup, indicating persistent vasodilator dysfunction after DES implantation.14 In the HATTRICK-OCT study, we found no differences between the 2 stent groups regarding CFR, IMR and FFR. Nevertheless, the proportion of patients with abnormal CFR <2.5 was 44.4% vs. 12.5% for the BP-SES vs. DP-ZES groups, respectively (P=0.06). The high rates may imply that the vasodilator function had not recovered completely with either stent, although signiicant difference between the stent groups was not seen. The higher occurrence of culprit lesion thrombus and aspiration thrombectomy in BP-SES as a factor predisposing to distal embolization is another possible cause of impaired CFR at 3 months. Whether this translates into adverse clinical outcome remains to be addressed in larger prospective studies. Study Limitations The current trial had a relatively small sample size, and therefore its results should be interpreted with caution. Moreover, the current OCT technology cannot detect tissue coverage <10 µm and thus, cannot identify very thin layers of endothelial coverage. Additionally, the absence of baseline OCT and vasodilator response data immediately after the index procedure prevents comprehensive interpretation of data. It cannot be conirmed whether malapposed struts are due to persistent acute or late acquired malapposition. The fact that no independent core lab was involved in data analysis is another potential limitation. Finally, the trial was underpowered to correlate clinical endpoints with OCT indings, and decision on the length of DAPT cannot be made based on these OCT results only. Therefore, larger prospective studies are needed. Conclusions In non-diabetic patients with ACS, neither of these newer generation stent devices was fully covered at 3 months follow-up. The percent of uncovered stent struts on OCT was lower for BP-SES compared with DP-ZES at 3-month follow-up, but CFR and IMR were similar between the groups. Acknowledgments The authors thank RN Minna Ampio, RN Kristiina Lahtola and RN Tuija Vasankari for their excellent technical assistance. Disclosures Conlicts of Interest: This study was supported by a scholarship for research within the area of ACS from the Finnish Cardiac Society (T.K.); by grants from the Finnish Foundation for Cardiovascular Research, Helsinki, Finland (T.K., J.K.E.A.); and by Turku University Hospital Research Foundation. The authors report no other relationships that could be construed as a conlict of interest. References 1. Palmerini T, Biondi-Zoccai G, Riva DD, Stettler C, Sangiorgi D, D’Ascenzo F, et al. Stent thrombosis with drug-eluting and bare-metal stents: Evidence from a comprehensive network meta-analysis. Lancet 2012; 379: 1393 – 1402. 2. Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, et al. Pathological correlates of late drug-eluting stent thrombosis: Strut coverage as a marker of endothelialization. Circulation 2007; 115: 2435 – 2441. 3. Miyazaki S, Hiasa Y, Takahashi T, Yano Y, Minami T, Murakami NF, et al. In vivo optical coherence tomography of very late drug-eluting stent thrombosis compared with late in-stent restenosis. Circ J 2012; 76: 390 – 398. 4. Virmani R, Guagliumi G, Farb A, Musumeci G, Grieco N, Motta T, et al. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: Should we be cautious? Circulation 2004; 109: 701 – 705. 5. Cook S, Ladich E, Nakazawa G, Eshtehardi P, Neidhart M, Vogel R, et al. Correlation of intravascular ultrasound indings with histopathological analysis of thrombus aspirates in patients with very late drugeluting stent thrombosis. Circulation 2009; 120: 391 – 399. 6. Barlis P, Regar E, Serruys PW, Dimopoulos K, van der Giessen WJ, van Geuns RM, et al. An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: A LEADERS trial sub-study. Eur Heart J 2010; 31: 165 – 176. 7. Hezi-Yamit A, Sullivan C, Wong J, David L, Chen M, Cheng P, et al. Impact of polymer hydrophilicity on biocompatibility: Implication for DES polymer design. J Biomed Mater Res A 2009; 90A: 133 – 141. 8. Kubo T, Akasaka T, Kozuma K, Kimura K, Fusazaki T, Okura HF, et al. Vascular response to drug-eluting stent with biodegradable vs. durable polymer. Circ J 2014; 78: 2408 – 2414. 9. Gutiérrez-Chico JL, van Geuns RJ, Regar E, van der Giessen WJ, Kelbæk H, Saunamäki K, et al. Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a luoropolymer-coated everolimus-eluting stent at 13-month follow-up: An optical coherence tomography substudy from the RESOLUTE All Comers trial. Eur Heart J 2011; 32: 2454 – 2463. 10. Hofma SH, van der Giessen WJ, van Dalen BM, Lemos PA, McFadden EP, Sianos G, et al. Indication of long-term endothelial dysfunction after sirolimus-eluting stent implantation. Eur Heart J 2006; 27: 166 – 170. 11. Togni M, Räber L, Cocchia R, Wenaweser P, Cook S, Windecker S, et al. Local vascular dysfunction after coronary paclitaxel-eluting stent implantation. Int J Cardiol 2007; 120: 212 – 220. 12. Kiviniemi T, Puurunen M, Schlitt A, Rubboli A, Karjalainen P, Nammas W, et al. Bare-metal vs. drug-eluting stents in patients with Circulation Journal Vol.79, February 2015 HATTRICK-OCT Trial 13. 14. 15. 16. 17. 18. 19. 20. 21. 367 atrial ibrillation undergoing percutaneous coronary intervention. Circ J 2014; 78: 2674 – 2681. Kiviniemi T, Puurunen M, Schlitt A, Rubboli A, Karjalainen P, Vikman S, et al. Performance of bleeding risk-prediction scores in patients with atrial ibrillation undergoing percutaneous coronary intervention. Am J Cardiol 2014; 113: 1995 – 2001. Karjalainen P, Kiviniemi TO, Lehtinen T, Nammas W, Ylitalo A, Saraste A, et al. Neointimal coverage and vasodilator response to titanium-nitride-oxide-coated bioactive stents and everolimus-eluting stents in patients with acute coronary syndrome: Insights from the BASE-ACS trial. Int J Cardiovasc Imaging 2013; 29: 1693 – 1703. Lehtinen T, Kiviniemi T, Ylitalo A, Mikkelsson J, Airaksinen J, Karjalainen PP. Early vascular healing after endothelial progenitor cell capturing stent implantation. J Invasive Cardiol 2012; 24: 631 – 635. Lahtela H, Rubboli A, Schlitt A, Karjalainen PP, Niemelä M, Vikman S, et al. Heparin bridging vs. uninterrupted oral anticoagulation in patients with atrial ibrillation undergoing coronary artery stenting: Results from the AFCAS registry. Circ J 2012; 76: 1363 – 1368. Annala A, Lehtinen T, Kiviniemi T, Ylitalo A, Nammas W, Karjalainen P. Vascular healing early after titanium-nitride-oxide-coated stent implantation assessed by optical coherence tomography. J Invasive Cardiol 2013; 25: 186 – 189. Pijls NHJ, De Bruyne B, Smith L, Aarnoudse W, Barbato E, Bartunek J, et al. Coronary thermodilution to assess low reserve: Validation in humans. Circulation 2002; 105: 2482 – 2486. Kim S, Kim J, Shin D, Kim B, Ko Y, Choi D, et al. Comparison of early strut coverage between zotarolimus- and everolimus-eluting stents using optical coherence tomography. Am J Cardiol 2013; 111: 1 – 5. Silber S, Kirtane AJ, Belardi JA, Liu M, Brar S, Rothman M, et al. Lack of association between dual antiplatelet therapy use and stent thrombosis between 1 and 12 months following resolute zotarolimuseluting stent implantation. Eur Heart J 2014; 35: 1949 – 1956. Kastrati A, Dibra A, Eberle S, Mehilli J, Suárez de Lezo J, Goy JJ, et al. Sirolimus-eluting stents vs paclitaxel-eluting stents in patients with coronary artery disease: Meta-analysis of randomized trials. JAMA 2005; 294: 819 – 825. 22. Xu B, Dou K, Lü S, Hou Y, Wang L, Chen Y, et al. A prospective multicenter parallel-controlled trial of TIVOLI biodegradable-polymerbased sirolimus-eluting stent compared to ENDEAVOR zotarolimuseluting stent for the treatment of coronary artery disease: 8-month angiographic and 2-year clinical follow-up. Chin Med J 2011; 124: 811 – 816. 23. Kan J, Chen F, Liu LY, Xu HM, Lin L, Liu Y, et al. Quantitative assessment of late lumen loss after biodegradable polymer and permanent polymer sirolimus-eluting stents implantation. Chin Med J 2013; 126: 1081 – 1085. 24. Ishihara T, Awata M, Sera F, Fujita M, Watanabe T, Iida O, et al. Arterial repair 4 months after zotarolimus-eluting stent implantation observed on angioscopy. Circ J 2013; 77: 1186 – 1192. 25. Qian J, Lansky AJ, Yang YJ, Qiao SB, Wu YJ, Chen J, et al. First report of a novel abluminal groove illed biodegradable polymer rapamycin-eluting stent in de novo coronary artery disease: Results of the irst in man FIREHAWK trial. Chin Med J 2012; 125: 970 – 976. 26. Hamon M, Niculescu R, Deleanu D, Dorobantu M, Weissman NJ, Waksman R. Clinical and angiographic experience with a third-generation drug-eluting Orsiro stent in the treatment of single de novo coronary artery lesions (BIOFLOW-I): A prospective, irst-in-man study. EuroIntervention 2013; 8: 1006 – 1011. 27. Togni M, Windecker S, Cocchia R, Wenaweser P, Cook S, Billinger M, et al. Sirolimus-eluting stents associated with paradoxic coronary vasoconstriction. J Am Coll Cardiol 2005; 46: 231 – 236. 28. Cortigiani L, Rigo F, Gherardi S, Sicari R, Galderisi M, Bovenzi F, et al. Additional prognostic value of coronary low reserve in diabetic and nondiabetic patients with negative dipyridamole stress echocardiography by wall motion criteria. J Am Coll Cardiol 2007; 50: 1354 – 1361. 29. Ascione L, Carlomagno G, Sordelli C, Iengo R, Monda V, Severino S, et al. Dipyridamole coronary low reserve stratiies prognosis in acute coronary syndrome patients without left anterior descending disease. Eur Heart J Cardiovasc Imaging 2013; 14: 858 – 864. 30. Gould KL, Lipscomb K. Effects of coronary stenoses on coronary low reserve and resistance. Am J Cardiol 1974; 34: 48 – 55. Circulation Journal Vol.79, February 2015