Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Preprint Article Version 1 Preserved in Portico This version is not peer-reviewed

Surgical Outcomes of Modified Intraocular Lens Suturing With Forceps-Assisted Haptics Extraction: A Clinical and Basic Evaluation

Version 1 : Received: 24 June 2024 / Approved: 25 June 2024 / Online: 26 June 2024 (05:08:19 CEST)

A peer-reviewed article of this Preprint also exists.

Sotani, Y.; Imai, H.; Kishi, M.; Yamada, H.; Matsumiya, W.; Miki, A.; Kusuhara, S.; Nakamura, M. The Surgical Outcomes of Modified Intraocular Lens Suturing with Forceps-Assisted Haptics Extraction: A Clinical and Basic Evaluation. J. Clin. Med. 2024, 13, 5522. Sotani, Y.; Imai, H.; Kishi, M.; Yamada, H.; Matsumiya, W.; Miki, A.; Kusuhara, S.; Nakamura, M. The Surgical Outcomes of Modified Intraocular Lens Suturing with Forceps-Assisted Haptics Extraction: A Clinical and Basic Evaluation. J. Clin. Med. 2024, 13, 5522.

Abstract

Background/Objectives: Postoperative intraocular lens (IOL) is a risk associated with IOL scleral fixation. However, the cause of IOL tilt during IOL suturing remains unclear. Therefore, this study aimed to evaluate the surgical outcomes of a modified IOL suturing technique and investigate the factors contributing to postoperative IOL tilt and decentration. Methods: We included 25 eyes of 22 patients who underwent IOL suturing between April 2018 and February 2020. A modified IOL suturing technique that decreased the need for intraocular suture manipulation was used. Factors contributing to IOL tilt and decentration were investigated using an intraoperative optical coherence tomography (iOCT) system. Results: The mean postoperative best-corrected visual acuity improved from 0.15 ± 0.45 to -0.02 ± 0.19 (p = 0.02). The mean IOL tilt angle at the last visit after surgery was 1.84 ± 1.28 degrees. The study revealed that the distance of the scleral puncture site from the corneal limbus had a stronger effect on IOL tilt; while, the suture position of the haptics had a greater effect on IOL decentration. Conclusions: The modified IOL suturing technique, which avoids intraocular suture handling, had favorable surgical outcomes with improved postoperative visual acuity and controlled IOL tilt and decentration. Accurate surgical techniques and careful measurement of distances during surgery are crucial for preventing postoperative IOL tilt and decentration.

Keywords

modified intraocular lens suturing; forceps-assisted; haptics extraction; surgical outcomes

Subject

Medicine and Pharmacology, Ophthalmology

Comments (0)

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.