Ex marking
IEC US (NEC 505) US (NEC 500)
Method of protection (optional except for I.S.) Permitted class
CENELEC
European standard Method of protection Group
Explosion protected Permitted class American national standard I.S. output Method of protection Group Gas group
Ex d [ia] IIC T5 Class I, Zone I, AEx d [ia] IIC T5 Explosionproof with I.S. Outputs, Class I, EEx d [ia] IIC T5 Division I, Groups A,B,C,D,T5 I.S. output
Method of protection Temperature class Permitted zone Explosion protected I.S. output Permitted gas group Temperature class (T5 & T6 optional) Temperature class Permitted division (optional except for division 2) Gas group Explosion protected Temperature class
Area classification
IEC CENELEC
NEC 505 NEC 500
INERIS
notified body
INERIS (*) is one of the notified bodies in European Union approved to carry out the conformity assessment procedures for equipment in hazardous areas. It can assist designers, manufacturers and users of such equipment. INERIS can also assume tests in order to obtain an overseas certification (Factory Mutual in States or CANMET in Canada, ).
US
Division 1
Training
I NERIS technical courses: Provide you the essential knowledges about the ATEX European compliance in order to obtain the marking. Analyse the key elements of the other new approach directives as Electromagnetic Compatibility or Machiner y directives. (Training on your site or at INERIS).
Marking
According to the ATEX directive Equipment group II (other than mines)
Category 1 (for zone 0 or 20) 2 (for zone 1 or 21) 3 (for zone 2 or 22) G for gases, vapours and mist D for dusts
Equipment group I
Category M1 and M2
re d u c i n g
r i s k ,
p ro t e c t i n g
e n v i ro n m e n t
The following figures inform you about relations between international applicable standards concerning protection methods and their applications according to hazardous areas classification.
Standards CENELEC
EN 50020 -------------
UL
UL 2279, Pt.11 ANSI/UL 913
FM
------------FM 3610
IEC
IEC 79-11 -------------
Zone 1
FM 3614 FM 3618 FM 3619 FM 3610 FM 3621 FM 3622 FM 3620 ------------------------FM 3611 -------------------------------------------------------------
CSA-E79-18 CSA-E79-1 CSA-E79-7 CSA-E79-11 CSA-E79-6 CSA-E79-5 CSA-E79-2 ------------------------CSA-E79-15 CSA-E79-15 CSA-E79-15 CSA-E79-15 -------------------------
IEC 79-18 IEC 79-1 IEC 79-7 IEC 79-11 IEC 79-6 IEC 79-5 IEC 79-2 ------------------------IEC 79-15 IEC 79-15 IEC 79-15 IEC 79-15 -------------------------
EN 50028 EN 50018 EN 50019 EN 50020 EN 50015 EN 50017 EN 50016 ------------------------EN 50021 EN 50021 EN 50021 EN 50021 -------------------------
Zone 2
Nonincendive NI Non-sparking device nA Restricted breathing nR Hermetically sealed nC Any Class I, Zone 0 or 1 method Any Class I, Div. 1 or 2 method
Other services
Risks due to electrostatic effects and lightning. Routine tests according to international certification standards (IEC,...) and others requirements. Training. Assistance to users: risks analysis, area classification,...
Class 1
Flammable gases, vapors or liquids
Area classification
Division 1 and Zone 0
Where ignitable concentrations of flammable gases, vapors or liquids can exist all of the time or some of the time under normal operating conditions.
Groups
Division 1 and 2
A B C D (Acetylene) (Hydrogen) (Ethylene) (Propane)
Zone 1
Where ignitable concentrations of flammable gases, vapors or liquids can exist some of the time under normal operating conditions.
Class 2
Combustible dusts
Area classification
Division 1
Where ignitable concentrations of combustible dusts can exist all of the time or some of the time under normal operating conditions.
Groups
Division 1 and 2
E (Metals) F (Coal) G (Grain)
Division 2
Where ignitable concentrations of combustible dusts are not likely to exist under normal operating conditions.
Class 3
Ignitable fibers & flyings
Area classification
Division 1
Where ignitable concentrations of ignitable fibers and flyings can exist all of the time or some of the time under normal operating conditions.
Groups
Division 1 and 2
None
Division 2
Where ignitable concentrations of ignitable fibers and flyings are not likely to exist under normal operating conditions.
(
Ingress Protection (IP)
FIRST NUMBER Protection against solid bodies SECOND NUMBER Protection against liquid
No protection Vertically dripping water 75 to 90 dripping water Sprayed water Splashed water Water jets Powerfull water jets Temporary immersion Continuous immersion
Reciprocal
agreements
(FMRC
(Factory Mutual Research Corporation)
1151 Boston-Providence Turnpike P.O. Box 9102 Nordwood MA 02062-9102 U.S.A. Tel: 781 255 4840 Fax: 781 762 9375 e.mail: Approvals@factory-mutual.com
0 1 2 3 4 5 6 7 8
No protection Objects greater Objects greater Objects greater Objects greater Dust-protected Dust-tight
50 mm 12 mm 2,5 mm 1 mm
Apparatus Grouping
TYPICAL GAS US (NEC 505) IEC CENELEC
Group IIC (Group IIB + H2) Group IIB Group IIA Group I
US (NEC 500)
Class I / Group A Class I / Group B Class I / Group C Class I / Group D Gassy mines
u.2-4 H1037 PF 115 H.1300 Budapest . HUNGARY Tel /Fax: 36 1 250 17 20 e.mail: bkiex@elender.hu
US (NEC 500)
T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6