APD100A-6: 100 kVA / 80 KW
APD100A-6: 100 kVA / 80 KW
APD100A-6: 100 kVA / 80 KW
POWERED by AKSA
APD100A-6
APD100A-6
100 80 90 72
Standby : Continuous running at variable load for duration of an emergency. No overload is permitted on these ratings. In accordance with ISO 3046 . Prime : Continuous running at variable load for unlimited periods with 10% overload available for 1 hour in any 12 hour period. In accordance with ISO 8528,ISO 3046.
High quality, reliable and complete power unit Compact design Easy start and maintenance possibility Every generating set is subject to a comprehensive test program which includes full load testing and checking and providing of all control and safety shut down functions testing Full engineered with a wide range of options and accessories: Canopy, sound proof canopy and on road trailer
Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.
ENGINE
AKSA
Model Engine Power Output at rated rpm Aspiration and Cooling Total Displacement No. of Cylinders and Build Engine Speed Bore and Stroke Compression Ratio Governor Fuel Consumption at full load Fuel Tank Capacity Oil Capacity Coolant Capacity Radiator Cooling Air Air Intake Engine Exhaust Gas Flow
A4CRX46TI 82 111.6 Turbocharged 4.58 4- Inline 1800 110X125 17:01 Electronic 18.5 Open: 195/Canopy: 195 14 26 132 6.842 18.527
Cooling radiator and fan Starter battery (with lead acid) including Rack and Cables Flexible fuel connection hoses and manual oil sump drain valve Industrial capacity exhaust silencer and steel bellows Jacket water heater(at automatic models) Operation manuals and circuit diagram documents
Heavy duty Aksa diesel engine Four stroke, water cooled, turbocharged Direct injection fuel system Mechanical Governor system 12/24 V D.C. starter and charge alternator Replaceable fuel filter, oil filter and dry element air filter
ALTERNATOR
Design Stator Rotor Insulation System Standard Temperature Rise Exciter Type Phase Rotation Alternator Cooling AC Waveform Total Harmonic Distortion
Brushless single bearing, revolving field 2/3 pitch Single bearing, flexible disc Class H 125 - 163C Continuous Self Excited A (U), B (V), C (W) Direct drive centrifugal blower fan No load < 1.5%. Non distorting balanced linear load < 5% <50 per NEMA MG1-22.43 <2%
Brushless, single bearing system, flexible disc, 4 poles Impregnation with tropicalised epoxy varnish Insulation class H Solid state Automatic Voltage Regulator Standard degree of protection IP21 (*IP22/IP23 is availab.) Stator winding with 2/3 pitch for improved harmonics Self-exciting and self-regulating
CONTROL SYSTEM
Control supervision and protection panel is mounted on the genset base frame. The control panel is equipped as follows: 1. Auto Mains Failure Control Panel Panel equipments: Control with AMF module Static battery charger Emergency stop push button a) Generating set control module DSE 6020 features: The module is used to monitor main supply and starts and stops of a standby generating set Micro-processor based design Automatic control of main and generator contactors Monitors engine performance and AC power output LED alarm indication Front panel configuration of timers and alarm trip points CAN and magnetic pick-up versions(specify on ordering) 4 digital inputs/3 analogue inputs 6 outputs(4 configurable on Magnetic Pick-up, 6 configurable on CANbus version) Easy push button control STOP/RESET - MANUAL - AUTO - TEST START b) Metering via LED display: Generator Volts (L-L / L-N) Engine oil pressure (PSI-Bar) Generator Ampere (L1,L2,L3) Engine temperature (C&F) Generator Frequency (Hz) Plant battery volts Engine hours run Mains Volts (Ph-Ph/Ph-N)
DSE 6020
c) Alarms: Over and Under Speed Low and High Battery Volt. Start and Stop Failure Charge fail Over Current Under / Over Generator Voltage Low Oil Pressure Emergency stop High engine temperature
d) LED Indications: Mains available Generator available Mains on load Generator on load
OPTIONAL EQUIPMENTS
Diesel Engine Oil heater Alternator 3/4 Pole Output Circuit Breaker Anti-condensation Heater Panel Charge ammeter Transfer Switch 3Pole Transfer Switch 4 Pole Earth Fault ,single set
Panel Charge ammeter Transfer Switch 3Pole Transfer Switch 4 Pole Earth Fault ,single set Accessories Bulk fuel tank Automatic filling system Fuel-water separator filter Low fuel level alarm Residential silencer Enclosure or sound proof canopy Trailer Manual oil drain pump Tool kit for maintenance
CHASSIS
The complete gen-set is mounted as whole on a heavy-duty fabricated, steel base frame Antivibration pads are fixed between the engine/ alternator feet and the base frame Base frame design incorporates an integral fuel tank (Up to 750 kVA) The generating set can be lifted or carefully pushed/ pulled by the base frame Dial type fuel gauge and drain plug on the fuel tank Forklift pockets within base frame (up to 500kVA)
CANOPY
All canopy parts are designed with modular principles Without welding assembly Doors on each side All metal canopy parts are painted by electrostatic polyester powder paint
Exhaust silencer is protected against environment influences Thermally insulated engine exhaust system Emergency stop push button is installed outside of the canopy Easy lifting and moving Easy maintenance and operation
Aksa Power Generation Evren Mah.Gulbahar Caddesi 1.Sokak Gunesli-Istanbul-TURKEY Tel:+90 212 478 66 66 Fax:+90 212 657 55 16 E-mail: aksa@aksapowergen.com www.aksapowergen.com Aksa Power Generation is a member of www.aksa.com.tr