Planos de Bafles Msl-6 - Ds - 2
Planos de Bafles Msl-6 - Ds - 2
Planos de Bafles Msl-6 - Ds - 2
FEATURES
Integrated control electronics and amplifiers High Power
TruPower Limiting(TPL)
Intelligent AC System
The MSL-6, Meyer Sounds largest self-powered speaker, is ideally suited for large-scale vocal public address applications as a stand-alone system, and for musical sound reinforcement in combination with Meyer self-powered subwoofers and/or the DS-2P mid-bass speaker. The MSL-6 features a 25 vertical coverage angle, permitting long-throw arrays with up to three vertical rows with minimal overlap between coverage areas. The center and outer high frequency horns utilize separate amplifier and control electronics to achieve a 30 horizontal coverage angle for a single MSL-6. Tight-packing two units together yields a 60 coverage angle. Since the MSL-6 is intended for tight packing only, array design is simple and modular: each additional unit increases the horizontal coverage by 30. The maximum horizontal array size is twelve units, resulting in a circular array with 360coverage. The MSL-6 contains amplifier and control electronics for two 12 low frequency cone drivers and three high frequency horn drivers (2 throat, 4 diaphragm) in a compact trapezoidal cabinet. Each 12 driver is independently amplified and contained in a horn-loaded vented enclosure. This
integrated design improves performance, durability, and reliability, eliminates amplifier racks, and simplifies setup and installation. The MSL-6 has twelve pivoting lift rings (six on top, six on bottom), each with a maximum working load capacity of 1500 lb (5:1 safety factor). Despite the inclusion of amplifier and control electronics, the MSL-6 is 14 shorter, and 25 lbs. lighter than the MSL-5. The MSL-6 cabinet is reinforced internally with steel girders. The MSL-6 employs TruPower limiting (TPL), the first limiting technique that accurately calculates the power dissipation within the speaker. TPL accounts for varying speaker impedance by measuring current, in addition to voltage, to compute the
power dissipation and voice coil temperature. TPL improves system performance before and during limiting by allowing the speaker to deliver its highest SPL across its entire frequency range. TPL also eliminates long-term power compression when the MSL-6 is operated at high levels for prolonged periods and extends the lifetime of amplifier and driver components. The MSL-6 can be equipped to operate with the Remote Monitoring System (RMS) network and software application. RMS displays signal and power levels, driver and cooling fan status, limiter activity, and amplifier temperature for all speakers in the network on a Windows based PC.
Meyer Sound
MSL-6 SPECIFICATIONS
Acoustic al1
(each Loudspeaker)
Meyer Sound Laboratories has devoted itself to designing, manufacturing, and refining components that deliver superb sonic reproduction. Every part of every component is designed and built to exacting specifications and undergoes rigorous, comprehensive testing in the laboratories.
Coverage Tr ansducers
(6dB points) Horizontal: 30; Vertical: 25 Low Frequency High Frequency HF DC Protection Acoustical Crossover Range Two 12 diameter MS-12 cone (3 voice coil) Three 2 throat, 4 diaphragm MS-2001A compression drivers Three 20 mf capacitors 500 Hz 1 kHz
Amplifiers
Type Complementary power MOSFET output stages class AB/H Burst Capability3 2480 Watts (620 Watts/channel) THD, IM, TIM < .02 % Type 10 k impedance, electronically balanced Connector XLR (A-3) male and female Nominal Input Level +4 dBu (1.23 Vrms)
4 Connector 250 V NEMA L6-20P (twistlock) inlet or IEC 309 male inlet 5 Automatic voltage selection 95 125 V / 208 235 V; 50 Hz/60 Hz Operational voltage range Turn on: 85 VAC; Turn off: 134 VAC; 50/60 Hz Turn on: 165 VAC; Turn off: 264 VAC; 50/60 Hz 230 V: 7 A 100 V: 16 A Max Continuous RMS Current (>10 sec) 115 V: 14 A 230 V: 13 A 100 V: 30 A Burst RMS Current (<1 sec) 115 V: 26 A 230 V: 18 Apk 100 V: 42 Apk Max Peak Current During Burst 115 V: 36 Apk Soft Current Turn-on Inrush current < 12 A @115 V
Audio Input
AC Power
Research remains an integral, driving force behind all production. Meyer strives for sound quality that is predictable and neutral over an extended lifetime and across an extended range.
Physic al
Height: 42.75 Width: 42.52 Depth: 32.28 475 lb. (216 kg) / Shipping: 513 lb. (257 kg) Two-piece, damped, hex-punched metal screen, grey foam covering 12-ply hardwood black textured, charcoal grey carpet, or weather-protected Twelve pivoting lift rings (6 on top and bottom); working load for each ring is 1500 lb with straight tensile pull. Safety factor is 5:1. Entire cabinet is reinforced with steel girders.
N ot e s
1. 2. 3. 4.
Measured at 3 non-axis, free field conditions, pink noise input, third-octave bands. Interpolated to 1 m. Nominal 8 resistive load, pink noise, 100 V peak. Other connectors available. For European installations, an IEC 309 connector (16A) can be installed. 5. The unit is rated at 88-125V and 182-235V, 50/60 Hz, to satisfy EC standards for -10% to 6% AC line voltage.
PHYSICAL DIMENSIONS
ALL UNITS IN INCHES
!
WARNINGS:
S PU H S PU H
-C
IRK
-C
IRK
UL
UL
-I T
RE
-I T
RE
European Office: Meyer Sound Germany GmbH Carl Zeiss Strasse 13 56751 Polch, Germany
MSL-6 - 04.053.025.01B
12.5 24.2 30.4 C.G. 30.4 29.4 Ref 42.8 C.G. 22.0 1.6 7.4 32.2 42.5 12.5 32.3
Top
(Rigging Typ, both ends)
Front
Side
Meyer Sound Laboratories, Inc. 2832 San Pablo Avenue Berkeley, CA 94702 tel: 510.486.1166 fax: 510.486.8356 e-mail: techsupport@meyersound.com http: www.meyersound.com
1998 Meyer Sound Laboratories, Inc. All rights reserved