Liquid Line Pressure Drop Calculation: m3/h 3000.00 MM 14.3000 kg/m3 884.50 MM 682.600

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 1

LIQUID LINE PRESSURE DROP CALCULATION

LIQUID FLOW RATE m3/h m3/s BPD US GPM kg/m3 LB/Ft3 LB/B LB/US G deg.API kg/h LB/h cP Pa.s b.a PSIA b.g PSIG mm inch 3000.00 0.8333 452858 13208 884.50 55.22 310.02 7.382 28.5 2653500 5849868 15.000 0.015 77.31 1121.00 83.93 1216.94 1.50 0.0591 0.72 X 52 3586 52000
28

input

Calculated Thickness Actual Thickness

LIQUID DENSITY

input

INSIDE DIAMETER

Mass Flow rate LIQUID VISCOSITY Line Bases of Design Departure Pressure Design Pressure
(see ASME B31.4) 1.1 to 1.25xDesign Pressure in b.g

Flow Area Flowing Temperature note : If Re<2100 then f=64/Re Liquid Velocity input Reynolds Number Moody Friction Factor Colebrook fonc.1 Colebrook fonc.2 Total Pressure Drop by Friction Specific Pressure drop by Friction Static Head (arrival - departure)
Negative Value Positive Value

mm inch mm inch m mm inch m2 deg.C m/s Ft/s Re f

13.058 0.5141 14.3000 0.5630 0.6826 682.600 26.8740 0.3660 20.0 2.28 7.47 91658 0.0188 0.019 7.301 73.30 1062.92 844.82 0.63 0.28 0.00 0.00 0.00
Gain Loss

input

input

input input

input 0.01876

Corrosion Allowance Construction Factor STEEL GRADE TENSILE STRESS of Steel Pipe
NOMINAL DIAMETER

input input input input input

b PSI m b/km PSI/100 Ft b m Ft

b.g PSIG
inch

For Nominal Diameter above or equals to 14" Nominal Diameter = Outside Diameter OUTSIDE DIAMETER m 0.7112 mm 711.200 inch 28.000 mm 0.0600 PIPE ROUGHNESS m 0.00006 Ft 0.00020 m 116300.0 LILE LENGTH km 116.300 Ft 381562 Departure Point Elevation m 0 Arrival Point Elevation m 0 Horizontal Length m 116300.000 Slope deg 0.00

input input

TOTAL PRESSURE DROP Total Specific Pressure Drop Arrival Pressure Line Inside Volume Steel Volume

b PSI m b/km PSI/100 Ft b.a PSIA m3 m3

73.30 1062.92 844.82 0.63 0.28 4.01 58.08 42560 3641


Date of Calcul . 23/01/95

input

input input

Negative Slope : Downward Flow / Positive Slope : Upward Flow

Rev.0