Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Calibracion Kits Msa

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Calibration Kits

For Calibrating Instruments and Sensors


MSA Calibration Kits, when used with the appropriate calibration gas, offer a quick, convenient, and economical method of checking the response of MSA gas sensors and gas detection instrumentation. There are fourteen types of calibration kits available, and one is made to calibrate your particular MSA sensor or instrument. These calibration kits contain all the necessary calibration components to calibrate your MSA equipment. They are housed in a lightweight carrying case so that they can be easily carried to the job site or sensor location.

A-CAL
1 2

Calibration Kit Number 40 -Diffusion Ultima, Ultima X & Toxgard II sensor for: Carbon monoxide Hydrogen Oxygen IR Combustible & CO2 Hydrogen sulde Nitric oxide Sulfur dioxide Ammonia ~Ethylene oxide Combustible gas 41 -Diffusion Ultima, Ultima X & Toxgard II sensors for: Chlorine * Arsine Chlorine dioxide Phosphine Nitrogen dioxide * Germane Hydrogen chloride ^ Diborane Hydrogen cyanide + Bromine Silane + Flourine 42 -Pumped Ultima, Ultima X & Toxgard II or RSS sensors for: Carbon monoxide Oxygen Hydrogen sulde Sulfur dioxide Nitric oxide Combustible gas 43 -Pumped Ultima, Ultima X & Toxgard II or RSS sensors for: Chlorine Chlorine dioxide Nitrogen dioxide Hydrogen chloride Hydrogen cyanide 44 -Ultima, Auto-calibration, MultiGard Cylinder holder provided instead of suitcase p/n 710483 45 -Diffusion sensors for: Carbon monoxide Oxygen Hydrogen sulde Nitrogen dioxide Nitric oxide 46 -Diffusion combustible (non Ultima sensors) 47 -Diffusion sensors for: Chlorine Sulfur dioxide Hydrogen chloride Nitrogen dioxide 48- Pumped Toxgard for: Chlorine Sulfur dioxide Hydrogen cyanide 49 -Z Gard for: Carbon monoxide R11 R12 R-22 R-134A Ammonia Nitrogen dioxide 50 -Chillgard RT, Chillgard L Series or Chemgard 51 -Model 3600 for: Carbon dioxide and all remote sensor models (F - Regulator) 52 -Model 3630 53 -SAFESITE

Regulator Kit 40 - F Kit 41 - E Kit 42 - H Kit 43 - H Kit 44 - I Kit 45 - E Kit 46 - E

Kit 47 - E Kit 48 - H Kit 49 - E Kit 50 - F Kit 51 - F or G or H Kit 52 - E Kit 53 - E, F, or H

Regulator types: E - 0.25 LPM, p/n 467895 F - 1.50 LPM, p/n 467896 G - Demand regulator, p/n 710288 H - Matched ow, p/n 697344 I - Constant pressure, p/n 710315

Calibration Gas Cylinder 00000000 - None required or see Calibration Gases, RP Type Table 2nd Calibration Kit Number 00 - None required or choose number from Item 1 2nd Regulator 0 - None required or choose number from Item 2 2nd Calibration Gas Cylinder 00000000 - None required or see Calibration Gases, RP Type Table

4 5 6

Typical Calibration Kit: Contains instruction sheet, zero and span cylinders, regulators, tubing and accessories all contained in a convenient carrying case.

PART NUMBER 10044014* 10028076* 479265 479266 806735 807386 807387 801041 801042 801043 801044 801045 801046 801047 801048 10028050 710882 10028052 10028054 10027938 10028048 10028056 10010162 804770* 710331* 10028066*+ 10028046 10022386 10028078* 10053747* 10028072* 710414* 10028060*+ 10028064* 10028062* 10089547 10028038*+ 10028032 801049 10028022 10028020 10028058* 10028074* 481317# 710332* 10028068* 493580 10028028 804532@ 10014894 710533* 711054 10028034 10028044 806905 803499 812785 710880> 804866 812823 710878> 813368 804870 813369 806904 812784 711474 803498 806907 803500 812787 710874> 806906 804868 812786 710876> 813370 813371 10014897* 10028070* 10028042

CHEMICAL NAME NH3 NH3 CO2 CO2 CO2 CO2 CO2 CO2, CH4 CO2, CH4 CO2, CH4 CO2, CH4 CO2, CH4 CO2, CH4 CO2, CH4 CO2, CH4 CO CO CO CO CO CO CO, CH4 CO CH4, O2 CO, CH4 O2, H2S CL2 CL2 H2 H2 HCL HCL HCN H2S H2S H2S H2S H2S Isobutylene CH4 CH4 CH4, 02 CH4, O2, CO CH4, O2, H2S NO N2 NO2 NO2 O2 O2 Pentane Pentane Phosphine C3H8 C3H8 C3H8, O2, CO R-11 R-11 R-11 R-11 R-12 R-12 R-12 R-113 R-113 R-114 R-123 R-123 R-123 R-123 R-134A R-134A R-134A R-134A R-22 R-22 R-22 R-22 R-500 R-502 Silane SO2 Zero Air

CONCENTRATION 300 ppm 25 ppm 2.50% 2000 ppm 100 ppm 1.50% 15% 1300 ppm, 2.5% 2000 ppm, 2.5% 3300 ppm, 2.5% 6600 ppm, 2.5% 1.3%, 2.5% 3.3%, 2.5% 6.6%, 2.5% 33.3%, 2.5% 50 ppm 60 ppm 100 ppm 200 ppm 300 ppm 400 ppm 60 ppm CO, 2.5% CH4 300 ppm CO, 1.45% CH4, 15% O2 300 ppm, 1.45%,15%, 10ppm 2 ppm 10 ppm 0.80% 500 ppm 40 ppm 10 ppm 10 ppm 5 ppm 10 ppm 15 ppm 40 ppm 250 ppm 100 ppm 2.50% 6.60% 1.45%, 15% 1.45%, 15%, 60 ppm 1.45%, 15%, 10 ppm 50 ppm 99.90% 5 ppm 10 ppm 5% 20.80% in Nitrogen 0.75% 1000 ppm 0.5 ppm 0.10% 0.60% 0.6%, 15%, 60 ppm 10 ppm 100 ppm 30 ppm 990 ppm 100 ppm 30 ppm 990 ppm 30 ppm 100 ppm 30 ppm 10 ppm 30 ppm 50 ppm 100 ppm 10 ppm 100 ppm 30 ppm 990 ppm 10 ppm 100 ppm 30 ppm 990 ppm 30 ppm 30 ppm 5 ppm 10 ppm 20.8% Oxygen in Nitrogen
Corporate Headquarters P.O. Box 426, Pittsburgh, PA 15230 USA Phone 412-967-3000 www.MSAnet.com U.S. Customer Service Center Phone 1-800-MSA-INST Fax 1-724-776-3280 MSA Canada Phone 1-800-672-2222 Fax 1-800-967-0398

DESCRIPTION Ammonia in Nitrogen Ammonia in Nitrogen Carbon Dioxide in Air Carbon Dioxide in Air Carbon Dioxide in Nitrogen Carbon Dioxide in Nitrogen Carbon Dioxide in Nitrogen Carbon Dioxide, Methane in Nitrogen Carbon Dioxide, Methane in Nitrogen Carbon Dioxide, Methane in Nitrogen Carbon Dioxide, Methane in Nitrogen Carbon Dioxide, Methane in Nitrogen Carbon Dioxide, Methane in Nitrogen Carbon Dioxide, Methane in Nitrogen Carbon Dioxide, Methane in Nitrogen Carbon Monoxide in Air Carbon Monoxide in Air Carbon Monoxide in Air Carbon Monoxide in Air Carbon Monoxide in Air Carbon Monoxide in Air Carbon Monoxide, Methane, 15% O2 in Nitrogen Carbon Monoxide, Methane, Oxygen in Nitrogen Carbon Monoxide, Methane, Oxygen, H2S in N2 Chlorine in Nitrogen (used for ClO2 Cal too) Chlorine in Nitrogen Hydrogen in Air Hydrogen in Nitrogen Hydrogen Chloride in Nitrogen Hydrogen Chloride in Nitrogen Hydrogen in Cyanide in Nitrogen Hydrogen Sulde in Nitrogen Hydrogen Sulde in Nitrogen Hydrogen Sulde in Nitrogen Hydrogen Sulde in Nitrogen Hydrogen Sulde in Nitrogen Isobutylene in Air Methane in Air Methane in Nitrogen Methane, Oxygen in Nitrogen Methane, Oxygen, Carbon Monoxide in Nitrogen Methane, Oxygen, Hydrogen Sulde in Nitrogen Nittric Oxide in Nitrogen Nitrogen (O2 Zero) Nitrogen Dioxide in Air Nitrogen Dioxide in Air Oxygen in Nitrogen Oxygen in Nitrogen, Zero Air except for 3600 Pentane in Air, Substitute for Ammonia Pentane in Air Phosphine in Nitrogen Propane in Air Propane in Air (Ultima Span) Propane, Oxygen, Carbon Monoxide in Nitrogen R-11 in Air R-11 in Nitrogen R-11 in Nitrogen R-11 in Air R-12 in N2 R-12 in Nitrogen R-12 in Air R-113 in Nitrogen R-113 in N2 R-114 in Nitrogen R-123 in Nitrogen R-123 in Nitrogen R-123 in Nitrogen R-123 in N2 R-134A in N2 R-134A in N2 R-134A in Nitrogen R-134A in Air5 R-22 in Nitrogen R-22 in Nitrogen R-22 in Nitrogen R-22 in Air R-500 in Nitrogen R-502 in Nitrogen Silane in Nitrogen Sulfur Dioxide in Air Zero Air
MSA Mexico Phone (52) 55 2122 5770 Fax (52) 55 5359 4330 MSA International Phone 412-967-3354 FAX 412-967-3451

Calibration kits available for all MSA s gas detection products.

*Note: All cylinders contain 98 liters at 1000 psi except those indicated by an *. They have 58 liters. 98 liters gives approximately 20 calibrations per cylinder. + Not to be used for Ultima sensors @ Used only for Chillgard RT, substitute for ammonia. # Used as zero air for O2 Ultima sensors and all infrared instruments. > Used for Z Gard only.

Note: This Bulletin contains only a general description of the products shown. While uses and performance capabilities are described, under no circumstances shall the products be used by untrained or unqualied individuals and not until the product instructions including any warnings or cautions provided have been thoroughly read and understood. Only they contain the complete and detailed information concerning proper use and care of these products.

ID 07-1701-MC / Jan 2008


MSA 2008 Printed in U.S.A.