Glycol Pumps
Glycol Pumps
Glycol Pumps
Glycol Pumps
Glycol Pumps
Dehydrator
Wet gas in
Wet Glycol
4-2
Natural Gas
Wet natural gas enters the bottom of the absorber. It flows upward through a packed bed or through a series of bubble cap or valve trays filled with glycol where thorough contact is made. The gas gives up water vapor to the glycol as it passes upward and leaves the absorber as dry gas ready to enter the sales line.
Glycol Pump
The Glycol Pump takes glycol at absorber pressure, moves it into the reboiler at atmospheric pressure, and then returns it to pressure adequate to drive the glycol back into the abosrber. All this is accomplished by utilizing some of the gas at absorber pressure to drive the system without an additional source of outside energy. The Glycol Pump operates in various demanding conditions: high temperature, high pressure, varied chemical contaminates, and potential of a wide range of abrasive materials. Nearly 50 years of demanding service have proven the ruggedness and dependability of the unique and robust design.
Glycol
The dry concentrated glycol is continuously pumped to the top tray of the absorber. As the glycol moves downward from tray to tray it absorbs the water vapor from the rising gas stream. The wet glycol is then removed at the bottom of the absorber and pumped through a large preheating coil in the surge tank. It then enters the still column at the top of the reboiler where the water vapor is stripped away as steam. The regenerated glycol spills down into the surge tank and is pumped to the top of the absorber to start another cycle.
Glycol Pumps
Function:
Circulates glycol in a dehydration system. Circulates amine in a desulphurizer system. Utilizes the energy of gas and glycol at absorber pressure as its source of power.
Features:
No auxiliary power required Eliminates need for level control and dump valve at absorber Low gas consumption Completely sealed system prevents glycol loss Only two moving assemblies Hydraulic cushioned check valves with removable seats of hardened stainless steel Circulation Rates: SC Series 8 - 200 gph PV Series 3 - 450 gph
High Pressure
Model Number 315 PV 1715 PV 4015 PV 9015 PV 21015 PV 45015 PV Capacity Gallons / Hour Minimum Maximum 3 13 8 40 12 40 27 90 66 210 166 450
PV
Working Pressure Minimum Maximum 100 1500 300 1500 300 1500 300 1500 400 1500 400 1500
SC
Working Pressure Minimum Maximum 100 500 100 500 100 500 100 500
Features:
Sock type element In line filter removal 1/4 NPT Bleed Valve connection Hammer union cap Solid mount 3/4 NPT inlet and outlet connections
4-3
Temperature Range: -20 to 650oF Working Pressure: 1500 psig Recommended Pumps:
315PV 4015PV 9015PV 2015SC 5015SC
Dehydration Equipment
Liquid Level Control
ULC
Features:
Direct acting Intermittent bleed pilot Simple installation Easy to use No adjustment required .65 specific gravity or higher
Bodies Available:
1 NPT Brass, Steel, or Stainless Steel 2 NPT Steel or Stainless Steel
Maximum W.P.: 1500 psig Supply Pressure: 30 psig max. Maximum Temperature: 200 F
o
Options:
4-4
Low density, high temperature float Vertical float adapter Supply Pressure: 0-35 psig maximum Vessel Operating Pressure: 50 to 4000 psig maximum Temperature Range: -20 to 200oF Optional elastomers provide higher maximum temperature Float Travel:3/4 maximum
Features:
Compact Design: installs inside a smaller turning space than brand F or N Low Friction Waggle Arm: no rotating stuffing box and related friction/stiction Snap or Throttle control in one pilot: simple adjustment to change from snap to throttle control with the turn of a knob. Intermittent-Bleed pilot meets BMP in the EPA Natural Gas Star Program. Built-in 40 micron supply gas filter Vibration Tough 1/4 NPT Tapped Vented Pilot: Easy to connect and pipe exhaust away if needed. Vertical or Horizontal Displacer: field configurable standards specified
THERES A LOT MORE TO GAS DEHYDRATION THAN THE KIMRAY GLYCOL PUMP!
Dehydration Equipment
Dump Valves and Burner Valves
Normal Service: Liquids Features:
Quick opening trim Travel indicator Available in Pressure Opening or Pressure Closing Field reversible actuator Teflon packed stuffing box requires no lubrication Open yoke design - accurate travel indication - complete isolation of actuator
Angle or Thru valve body Carbide trim Ideal for high pressure differential On / Off service Valve Connection 1 2 Available Orifice Sizes 1/8, 3/16, 1/4, 3/8 1/4, 3/8, 1/2, 3/4, 1
Construction Materials:
Valve Body Stem Plug Cage Actuator Seat Diaphragms High Pressure Motor Valve Steel 303 Stainless 303 Stainless Steel Ductile Iron Steel Nitrile/Nylon Non-Freeze High Pressure Dump Steel 303 Stainless Carbide Steel Ductile Iron D2 Steel or Carbide Nitrile/Nylon
SMS
Standard actuator has an effective diaphragm area of 30 square inches. 65 Topworks has an effective area of 65 square inches, which allows a wider adjustable spring range. Maximum Pressure Drop:
Maximum Working Pressure: 4000 psi Temperature Range: -20o to 200o F Options:
Elastomers: HSN, Viton, Aflas Trim Material: Stainless Steel, Carbide
4-5
65 SMS
SMS - 1/4 - 2000 psi 3/8 - 800 psi 1/2 - 450 psi 65 SMS - 1/4, 3/8, 1/2 - 4000 psi
SMT DAB
Pressure opening Burner Valve used where a reduced inner valve is desired and manifold pressures do not exceed 25 psig.
Construction Materials:
Body Design Pressure Stem Plug Seat Cast Iron Scrd. 175 psi Flgd. 175 psi 303 Stainless Ductile Iron Nitrile Ductile Iron Scrd. 300 psi Flgd. 250 psi 303 Stainless Ductile Iron Polyurethane Nitrile/Nylon Steel Flgd. 285 psi 303 Stainless Steel Polyurethane Nitrile/Nylon
SMT ADA
Diaphragms Nitrile/Nylon
Pressure opening Burner Valve for throttling or snap action service and where manifold pressures do not exceed 40 psig.
Sizes available:
1 NPT 2 NPT, Flanged
THERES A LOT MORE TO GAS DEHYDRATION THAN THE KIMRAY GLYCOL PUMP!
Dehydration Equipment
Thermostats & Supply Gas Regulator
Thermostat Features:
Single adjustment High accuracy Intermittent-bleed construction Bi-metalic sensing element
T 12
T 12M
Temperature Range:
T 12, T 18 HT 12, HT 18 Pilot Guard -30o to 400o F -34o to 204o C -30o to 750o F -34o to 399o C -30o to 2100o F -34o to 1149o C
For temperature controlled system shutdown until manually reset Shuts off when system temperature exceeds setpoint
Options:
Elastomers: HSN, Viton, Aflas Metal Material: 316 Stainless Steel internal exposed parts
Pilot Guard
HT12 PG
Indirect action for system shut-down when pilot flame goes out. Also used in direct mode for high stack temperture shutdown
4-6
SGR
Connections:
Inlet and Outlet - 1/4 NPT
Operating Temperature:
0o to 200oF (-18oC to 93oC)
Outlet Pressure:
0 to 125 psi
Construction Materials:
Body: Aluminum or 316 Stainless Steel Diaphragm: Polyurethane Seat: Nylon
THERES A LOT MORE TO GAS DEHYDRATION THAN THE KIMRAY GLYCOL PUMP!