Water Tank To Column Detail: Advanced Diploma of Building Design Footing Layout Student Accommodation S01
Water Tank To Column Detail: Advanced Diploma of Building Design Footing Layout Student Accommodation S01
Water Tank To Column Detail: Advanced Diploma of Building Design Footing Layout Student Accommodation S01
6
SPOON DRAIN WATER TANK FOOTING BOND BEAM 400 x 500 WITH 3N12 TOP AND BOTTOM. PROVIDE N12-300 CLOSED TIES
COLUMN REINFORCEMENT BARS INTO WATERTANK FOOTING TO STRUCTURAL ENGINEERS SPECIFICATIONS AND DETAILS
2 S01
GATIC CIRCULAR CONCRETE COVER UNIT IN ACC.TO MANUF' SPECS AND DETAILS SITE BOUNDARY
C1
C2
C3
7
500dia. BORE PILE WITH 6N20 (40 COVER) R10-250 HELICAL TIES ANCHORED AS PER STRUCTURAL ENG. SPECS SITE BOUNDARY
4
S01
1
SFL GROUND
PROVIDE N12 - 400 L SHAPED CONNECTION BARS NGL PROVIDE N16 CONNECTION BARS 900 LONG 500 INTO PILE ISOLATION VIBRATION REFER TO MANUF' SPECS AND DETAILS SHOTCRETE WALL WITH CONNECTION PINS TO PILES N12 - 600 x 300 LONG 100mm THICK RC WALL WITH SL82 CENTRALLY SPOON DRAIN
1:200 FALL
1000
1:200 FALL
C4 GATIC FLOOR WASTE AND CONNECT TO S/WATER SYSTEM IN ACCORDANCE WITH CML ENGINEERS DRAWINGS AND DETAILS TO THE SATISFACTION OF THE LOCAL AUTHORITIES
C5
C6
8
600mm x 50d SWALE DRAIN WITH GRATE IN ACCORDANCE TO MANUF' SPECIFICATION 150dia PERFORATED PIPE IN ACCORDANCE WITH ENGINEERS SPECS AND DETAILS 600 x 600 DRAINAGE PIT
1:200 FALL
500dia. CONTIGUOUS CONC. PILE TO BOUNDARY 100mm SHOT CRETE TO FACE REFER TO STRUCTURAL ENG. DRWGS AND DTLS. PROVIDE APPROVED WATERPROOFING TO SELECTED EXTERNAL WALLS BELOW FINISHED GROUND IN ACCORDANCE WITH SELECTED MANUF'S SPECIFICATIONS 500dia BORE PILE WITH 6N20 (40 COVER) R10-250 HELICAL TIES ANCHORED AS PER STRUCTURAL ENG. SPECS
5 S01
SITE BOUNDARY 150,000 ltr CONCRETE UNDERGROUND WATER TANK RAFT FOUNDATION WITH SLAB MESH IN BOTTOM FACE REFER TO STRUCTURAL ENG. SPECS AND DTLS. PROVIDE WATER PROOFING ADMIXTURE (XYPEX OR SIMILAR) ACC. TO MANUF' SPECIFICATIONS AND DETAILS
7
S01
1
S01
2
REINFORCED INTERNAL LOAD BEARING WALL
150mm CONCRETE PAVEMENT. SLAB MESH TO STRUCTURAL ENGINEERS DRAWINGS AND DETAILS 150mm CONCRETE LOADBEARING WALLS. TIE DOWN BOLT ANCHORED TO PAVEMENT
BOND BEAM 500 x 600 WITH 3N12 TOP AND BOTTOM. PROVIDE N12 - 300 CLOSED TIES
SFL GROUND
ISOLATION VIBRATION BEARINGS CONNECTION TO MANUF' SPECS REINFORCEMENT CAGE 6/N16 10mm ROUND BARS WITH 40mm CONCRETE COVER
1000
NGL
500dia. CONTIGUOUS CONC. PILE TO BOUNDARY 100mm SHOT CRETE TO FACE REFER TO STRUCTURAL ENG. DRWGS AND DETAILS. PROVIDE APPROVED TANKING AND WATER PROOFING TO SELECTED EXTERNAL WALLS BELOW FINISHED GROUND IN ACCORDANCE WITH SELECTED MANUF'SPECIFICATIONS
EARTH
6
5
S01
S01
EARTH
6
S01
6
150mm CONCRETE GROUND FLOOR PAVEMENT 150mm REINFORCED CONCRETE LOADBEARING WALLS
7
GATIC CIRCULAR COVER UNIT IN ACC. TO MANUF'SPECS 100mm THICK RC WALL WITH SL82 CENTRALLY
1 S02
8
MANHOLES IN BLOCKWORK FOR WATERTANK MAINTENANCE BASEMENT RAMP
SFL GROUND
300X400 CONCRETE BEAM CONTIGUOUS BORED PIER RETAINING WALL TO ENG.DESIGN REINFORCEMENT CAGE 6/N16 10mm ROUND BARS WITH 40mm CONCRETE COVER ISOLATION VIBRATION (ELASTROMERIC BEARINGS) 250mm BONDEK TO MAN.SPECS 150mm BASEMENT PAVEMENT 500mm ROUND CONCRETE COLUMN 20mm MAIN BARS COLUMN STARTER BARS NGL
1220 100mm SHOT CRETE WALL WITH CONNECTION PINS TO PILE N12-600 x 300 LONG BOUNDARY
1000
NGL 100mm SHOTCRETE 600mmX 50D DRAINAGE SWALE DRAIN
500dia CONTIGUOUS BORED PILE WITH 6N20 (40 COVER) R10-250 HELICAL TIES ANCHORED AS PER STRUCTURAL ENG. SPECS
7
S01
4
S01
150,000LTR REINFORCED UNDERGROUND CONCRETE WATER TANK RAFT FOOTING SUPPORTING SUPER STRUCTURE
3
S01
2
S01
No.
Description
Date
ADDRESS: CLIENT:
S01
20/11/2013 2:46:28 PM
STUDENT ACCOMMODATION
FOOTING LAYOUT
1
COLORBOND KLIP LOCK SHEET AT 2 DEGREE min. ROOF PITCH. 150dia DOWNPIPES. CONNECT TO STORM WATER SYSTEM AS PER ENG. DETAILS TO THE SATISFACTION OF LOCAL AUTHORITIES. ( LYSAGHT TRIMDEK COLORBOND STEEL CAPPING AND FLASHING)
2
FIRE ISOLATED STAIRS
350mm LIVE GREEN ROOF. WATERPROOFING AND TANKING IN ACCORDANCE TO ENGINEER SPECIFICATIONS AND DRAWINGS 8mm FIRELITE PLUS LAMINATED PREMIUM GRADE CERAMIC GLASS CURTAIN WALL OR SIMILAR. TO BE FIRE RATED AND IMPACT SAFETY RATED WITH HOLLOW METAL STEEL FRAME IN ACC.TO SELECTED MANUF' SPECIFICATIONS AND DETAILS. PROVIDE DRENCHING SYSTEM TYPE B CONSTRUCTION
3
20mm VIRIDIAN TRAFFICAL LOW E TRIANGULAR GLASS ROOF PANELS @ 10 DEGREE PITCH. WATERPROOFING AND TANKING TO ENG. SPECIFICATIONS AND DRAWINGS
4
OPERABLE ALUMINIUM HORIZONTAL LOUVERS BOUNDED TO 75mm SHS COLUMNS @ 1600mm c/c WATERPROOFING/ TANKING IN ACCORDANCE TO ENG. SPECS AND DETAILS
5
REINFORCED CONCRETE PARAPET WALL @1800mm HEIGHT WITH 400mm W x 160mm D BOX GUTTER @ 1:200 FALL TO 150dia DOWNPIPES. CONNECT TO STORM WATER SYSTEM AS PER ENG. DETAILS TO THE SATISFACTION OF LOCAL AUTHORITIES. ( LYSAGHT TRIMDEK COLORBOND STEEL CAPPING AND FLASHING TO TOP OF ALL PARAPET WALLS IN ACC. TO MANUFACTURERS SPECIFICATIONS. 250mm x 150mm CONCRETE BUND. WITH FIXED STEEL PLATE TO ENGINEERS DRAWINGS AND DETAILS.
5
S05
135mm X 32mm BLACKBUTT HARDWOOD TIMBER DECKING @ 2 DEGREES SLOPE. WATERPROOFING AND TANKING TO ENGINEERS SPECIFICATIONS AND DETAILS.
SERVICE SHAFT
LIFT SHAFT
4mm ALPOLIC FACADE CLADDING FLOATING PANELS. FIXING AND CONNECTION DETAILS IN ACCORANCE WITH MANUFACTURE SPECISIFCATIONS
600
U401
U402
U403
3000
PASSAGE
U404
U405
PASSAGE
U406
1200 x 2100 SELF CLOSING FIRE RATED DOOR. MUST HAVE AN FRL NOT LESS THAN -/120/30 TO ENGINEERS SPECIFICATION AND DETAILS
'CORRIDOR BOUNDING WALLS' REINFORCED CONCRETE PRECAST WALLS TO BE LINED WITH 16mm FYRCHEK FIRE RATED PLASTERBOARD TO BOTH SIDE OF WALL FRL 30/30/30. TO ENGINEERS SPECIFICATIONS AND DETAILS 8.38mm VIRIDIAN VLAM TOUGHENED GRADE A&B SAFETY GLASS PANELS WITH GUARDRAIL CONTINUOUS BALASTRADE TO BE OF TOUGHENED AND LAMINATED GLASS OR SIMILAR IN ACCORDANCE TO MANUFACTURER SPECIFICATIONS AND DETAILS 300x400 REINFORCED CONCRETE TRANSFER BEAM REFER TO STRUCTURAL ENG. DRAWINGS AND SPECIFICATIONS
600
PASSAGE
U304
U305
PASSAGE
U306
8mm FIRELITE PLUS LAMINATED PREMIUM GRADE CERAMIC GLASS CURTAIN WALL OR SIMILAR TO BE FIRE RATED AND IMPACT SAFETY RATED WITH HOLLOW METAL STEEL FRAME IN ACC.TO SELECTED MANUF' SPECIFICATIONS
3000
SFL LEVEL 3
SUSPENDED REINFORCED CONCRETE FLOOR SLAB AND BEAM. THREADED TIE BAR SCREWED INTO CAST IN FURRULLES PRIOR TO CASTING FLOOR REFER TO STRUCTURAL ENGINEERS DAWINGS DETAILS TYP. PROVIDE 50mm SET DOWN TO WET AREAS/75mm SET DOWN TO BALCONY AREAS.
10450
600
SERVICE SHAFT
LIFT SHAFT
U201
U202
U203
'FIRE ISOLATED STAIR SHAFT' 150mm TILT UP PRECAST CONCRETE PANEL WALLS FRL NOT LESS THAN 120/120/120. PROVIDE A CRF OF NOT LESS THAN 2.2 TO ALL FLOOR COVERING AND FINISHES IN ACCORDANCE TO ENGINEERS SPECIFICATION & DETAILS
PASSAGE
U204
U205
PASSAGE
U206
3000
ALL BOUNDING DOORS TO CORRIDOR/ PASSAGE WAY TO BE FIRE RATED FRL -/60/30 TO ENGINEERS SPECIFICATIONS AND DETAILS
600
PASSAGE
U104
U105
PASSAGE
U106
RONDO SUSPENED CEILING SYSTEM OR SIMILAR WITH 16mm FYRCHEK FIRE RATED PLASTERBOARD FRL 30/30/30 FOR FLUSH PLASTER FINISH AND SELECTED PAINT FINISH OVER. REFER TO SELECTED MANUF'SPECIFICATIONS AND DETAILS
3000
SERVICE SHAFT
LIFT SHAFT
3000
'LIFT SHAFT'150mm TILT UP PRECAST CONCRETE PANEL WALLS. FRL NOT LESS THAN 60/60/60 PROVIDE SUSTAINABLE AIR FLOW TO TOP OF LIFT IN ACCORDANCE TO ENGINEERS SPECIFICATION AND DETAILS. .
LAUNDRY
LIFT/LOBBY
U101D
FOYER/RECEPTION
COMMON
ENTRANCE
BASEMENT CARPARK
GERB ISOLATION VIBRATION BEARINGS CONNECTIONS TO MANUFACTURERS SPECIFICATIONS.
BASEMENT CARPARK
REINFORCED CONCRETE STAIR AND LANDINGS IN ACCORDANCE WITH STRUCTURAL ENGINEER SPECIFICATIONS AND DETAILS 100mm SHOT CRETE TO FACE IN ACC. TO MANUFACTURERS SPECIFICATIONS
SFL BASEMENT
350 dia. CONTIGUOUS CONC. PILE TO BOUNDARY 100mm SHOT CRETE TO FACE REFER TO STRUCTURAL ENG. DRWGS AND DETAILS. PROVIDE APPROVED TANKING AND WATER PROOFING TO SELECTED EXTERNAL WALLS BELOW FINISHED GROUND IN ACC. WITH SELECTED MANUF' SPECIFICATIONS 'HYDRAULIC LIFT SHAFT' 2000mm W x 2400mm D SHAFT WITH 1150mm D OVERRIDE PIT. HARMEL HYDROLIC LIFT OR SIMILAR 1100mm W x 2100MM L x 2200mm H REFER TO SELECTED MANUFACTURERS SPECIFICATION AND DETAILS
-2300
PIT
600 x 50d DRAINAGE SWALE DRAIN. CONNECT TO PIT AND GATIC FLOOR WASTE. DISCHARGE AND CONNECTION TO STORMWATER AS PER ENGINEERS DETAILS TO THE SATISFACTION OF LOCAL AUTHORITIES
'POWER GENERATOR' 150mm TILT UP PRECAST PANEL WALLS. FRL NOT LESS THAN 120/120/120. PROVIDE SELF CLOSING FIRE DOOR FRL NOT LESS THAN /120/30 REFER TO ENGINEERS SPECIFICATION AND DETAILS
500dia. ROUND REINFORCED CONCRETE COLUNM TO WATERTANK. PROVIDE APPROVED TANKING/WATERPROOFING REFER TO ENGINEERS SPECIFICATIONS AND DRAWINGS
150,000 LTR REIFORCED CONCRETE WATERTANK RAFT FOUNDATION WITH SLAB MESH IN BOTTOM FACE REFER TO STRUCTURAL ENGINEERS SPECS. AND DETAILS.
SUSPENDED REINFORCED CONCRETE FLOOR SLAB AND BEAM TO GROUND FLOOR AREAS. THREADED TIE BAR SCREWED INTO CAST IN FURRRULES PRIOR TO CASTING FLOOR REFER TO STRUCTURAL/CIVIL ENGINEERS DRAWINGS AND DETAILS TYP. PROVIDE 50mm SET DOWN TO WET AREAS/75mm SET DOWN TO BALCONY AREAS
200mm STRUCTURAL BLOCKWORK WITH MANHOLES. WATERPROOFING AND TANKING TO ENGINEERS SPECIFICATIONS AND DRAWINGS
REINFORCED CONCRTE FLOOR SLAB AT GRADE TO BASEMENT CARPARK. REFER TO STRUCTURAL ENG. DRAWRINGS AND DETAILS TYP. PROVIDE 0.2mm WATERPROOF MEMBRANE ON 50mm COMPACTED SAND BED
1
S02
NORTH-SOUTH SECTION
1 : 50
No.
Description
Date
ADDRESS: CLIENT:
S02
20/11/2013 2:46:29 PM
STUDENT ACCOMMODATION
9
1 --S05
8
350mm LIVE GREEN ROOF. WATERPROOFING AND TANKING IN ACCORDANCE TO ENGINEER SPECIFICATIONS AND DRAWINGS
20mm VIRIDIAN TRAFFICAL LOW E TRIANGULAR GLASS ROOF PANELS @ 10 DEGREE PITCH. WATERPROOFING AND TANKING TO ENG. SPECIFICATIONS AND DRAWINGS 135mm X 32mm BLACKBUTT HARDWOOD TIMBER DECKING @ 2 DEGREES SLOPE. WATERPROOFING AND TANKING TO ENGINEERS SPECIFICATIONS AND DETAILS.
16-17 PASSANGER LIFT WITH CENTRE PARTING DOORS THROUGH CAR CONATINED WITHIN IN CONCRETE SHAFT FRL 120/120/120. PROVIDE FIRELITE PLUS FIRE RATED PREMIUM CERAMIC GLASS DOOR IN ACC. TO MANUF' SPECIFICATIONS AND DETAILS
7
8mm FIRELITE PLUS LAMINATED PREMIUM GRADE CERAMIC GLASS CURTAIN WALL OR SIMILAR TO BE FIRE RATED AND IMPACT SAFETY RATED WITH HOLLOW METAL STEEL FRAME IN ACC.TO SELECTED MANUF' SPECIFICATIONS OPERABLE ALUMINIUM HORIZONTAL LOUVERS . WATERPROOFING/TANKING IN ACCORDANCE TO ENG. SPECS AND DETAILS 250mm x 150mm CONCRETE BUND. WITH FIXED STEEL PLATE TO ENGINEERS DRAWINGS AND DETAILS.
4mm ALPOLIC FACADE CLADDING FLOATING PANELS. FIXING AND CONNECTION DETAILS IN ACCORANCE WITH MANUFACTURE SPECISIFCATIONS
REINFORCED CONCRETE PARAPET WALL @1800mm HEIGHT WITH 400mm W x 160mm D BOX GUTTER @ 1:200 FALL TO 150dia DOWNPIPES. CONNECT TO STORM WATER SYSTEM AS PER ENG. DETAILS TO THE SATISFACTION OF LOCAL AUTHORITIES. ( LYSAGHT TRIMDEK COLORBOND STEEL CAPPING AND FLASHING TO TOP OF ALL PARAPET WALLS IN ACC. TO MANUFACTURERS SPECIFICATIONS.
600
1
S06
BALCONY
2400
UNIT
PASSAGE
PASSAGE
UNIT
BALCONY
'CORRIDOR BOUNDING WALLS' REINFORCED CONCRETE PRECAST WALLS TO BE LINED WITH 16mm FYRCHEK FIRE RATED PLASTERBOARD TO BOTH SIDE OF WALL FRL 30/30/30. TO ENGINEERS SPECIFICATIONS AND DETAILS 8.38mm VIRIDIAN VLAM TOUGHENED GRADE A&B SAFETY GLASS PANELS WITH GUARDRAIL CONTINUOUS BALASTRADE TO BE OF TOUGHENED AND LAMINATED GLASS OR SIMILAR IN ACCORDANCE TO MANUFACTURER SPECIFICATIONS AND DETAILS
1200
600
BALCONY
2400
1200
UNIT
PASSAGE
PASSAGE
UNIT
BALCONY
150mm REINFORCED CONCRETE WALL PANEL LINED WITH PLASTERBOARD. TO WET AREAS LINE WALLS WITH VILLABOARD/WATERPROOFING PLASTER BOARD FOR STOPPED UP FINISH. PROVIDE PAINT FINISH AS APLLICABLE.
150mm REINFORCED CONCRETE BALCONY BALASTRADE @ 1200mm HEIGHT PROVIDE TO ENG. SPECIFICATIONS & DRAWINGS PAINT & FINISH AS APPLICABLE.
2400
BALCONY
1200
UNIT
PASSAGE
PASSAGE
UNIT
BALCONY
ALL NON LOADBEARING WALL TO BE RONDO QUITE WALL STEEL STUD SYSTEM AT 600max CTS nom. WITH 16mm GYPROCK FYRCHEK PLASTERBOARD AND 6mm CEMI SEAL WALLBOARD ON BOTH SIDE. PROVIDE TSB4/ASB4 POLYESTER BATTS FRL 60/60/60
SFL LEVEL 2
SUSPENDED REINFORCED CONCRETE FLOOR SLAB AND BEAM. THREADED TIE BAR SCREWED INTO CAST IN FURRULLES PRIOR TO CASTING FLOOR REFER TO STRUCTURAL ENGINEERS DAWINGS DETAILS TYP. PROVIDE 50mm SET DOWN TO WET AREAS/75mm SET DOWN TO BALCONY AREAS.
7300
600
BALCONY
2400
UNIT
PASSAGE
PASSAGE
UNIT
BALCONY
SELECTED CERAMIC FLOOR TILES TO ALL EXTERNAL BALCONIES ON GRADED MORTOR BED & APPROVED WATERPROOFING MEMBRANE. WATERPROOFING LAID IN ACC. WITH MANUF'SPECIFICATIONS. FALL TO GATIC WASTE OUTLET AND CONNECT TO STORMWATER SYSTEM AS PER CML ENGINEERS DRAWINGS & DETAILS TO THE SATISFACTION OF THE LOCAL AUTHORITIES TYP.
1200
600
VIRIDIAN GRADE A SAFETY GLASS PANELS WITH GUARDRAIL CONTINUOUS BALASTRADE TO BE OF TOUGHENED GLASS OR SIMILAR IN ACCORDANCE TO MANUFACTURER SPECIFICATIONS AND DETAILS
2400
CLEAN/STORE
PASSAGE
PASSAGE
DIS'UNIT
RONDO SUSPENED CEILING SYSTEM OR SIMILAR WITH 16mm FYRCHEK FIRE RATED PLASTERBOARD FRL 30/30/30 FOR FLUSH PLASTER FINISH AND SELECTED PAINT FINISH OVER. REFER TO SELECTED MANUF'SPECIFICATIONS AND DETAILS
SFL GROUND
ISOLATION VIBRATION BEARINGS CONNECTIONS TO MANUFACTURERS SPECIFICATIONS. 300x400 REINFORCED CONCRETE TRANSFER BEAM REFER TO STRUCTURAL ENG. DRAWINGS AND SPECIFICATIONS
1000
CARPARK RAMP
350 dia. CONTIGUOUS CONC. PILE TO BOUNDARY 100mm SHOT CRETE TO FACE REFER TO STRUCTURAL ENG. DRWGS AND DETAILS. PROVIDE APPROVED TANKING AND WATER PROOFING TO SELECTED EXTERNAL WALLS BELOW FINISHED GROUND IN ACC. WITH SELECTED MANUF'SPECIFICATIONS
BASEMENT CARPARK
100mm SHOT CRETE LAGGING TO FACE IN ACC. TO MANUFACTURERS SPECIFICATIONS
SFL BASEMENT
REINFORCED CONCRETE RAMP REFER TO STRUCTURAL ENG. DRWGS AND SPECIFICATION DETAILS
UNDERGROUND WATERTANK
SUSPENDED REINFORCED CONCRETE FLOOR SLAB AND BEAM TO GROUND FLOOR AREAS. THREADED TIE BAR SCREWED INTO CAST IN FURRRULES PRIOR TO CASTING FLOOR REFER TO STRUCTURAL/CIVIL ENGINEERS DRAWINGS AND DETAILS TYP. PROVIDE 50mm SET DOWN TO WET AREAS/75mm SET DOWN TO BALCONY AREAS REINFORCED CONCRTE FLOOR SLAB AT GRADE TO BASEMENTCARPARK. REFER TO STRUCTURAL ENG. DRAWRINGS AND DETAILS TYP. PROVIDE PROVIDE 0.2mm WATERPROOF MEMBRANE ON 50mm COMPACTED SAND BED EARTH
-2300
500dia. ROUND REINFORCED CONCRETE COLUNM TO WATERTANK. PROVIDE APPROVED TANKING/WATERPROOFING IN ACC. TO ENGINEERS SPECIFICATION AND DETAILS
150,000 LTR REIFORCED CONCRETE WATERTANK RAFT FOUNDATION WITH SLAB MESH IN BOTTOM FACE REFER TO STRUCTURAL ENGINEERS SPECS. AND DETAILS.
1
S03
EAST-WEST SECTION
1 : 50
No. Description Date
20/11/2013 2:46:30 PM
STUDENT ACCOMMODATION
ADDRESS: CLIENT: 69 YOUNG STREET, FRANKSTON ROARK DEVELOPMENT PTY LTD
S03
7
1000
GENERAL NOTES
RAMPS SHALL COMPLY WITH THE FOLLOWING: (A) THE MAXIMUM GRADIENT OF A RAMP EXCEEDING 1900 MM IN LENGTH SHALL B1 IN 14. (B) THE GRADIENT OF A RAMP SHALL BE CONSTANT THROUGHOUT ITS LENGTH WITH A MAXIMUM ALLOWABLE TOLERANCE OF 3% PROVIDED NO SECTION OF THE RAMP IS STEEPER THAN 1 IN 14. (C) RAMPS SHALL BE PROVIDED WITH LANDINGS, AS SPECIFIED IN AT THE BOTTOM AND AT THE TOP OF THE RAMP AND AT INTERVALS NOT EXCEEDING THE FOLLOWING: (I) FOR RAMP GRADIENTS OF 1 IN 14, AT INTERVALS NOT GREATER THAN 9 M. (II) FOR RAMP GRADIENTS STEEPER THAN 1 IN 20, AT INTERVALS NOT GREATER THAN 15 M. (III) FOR RAMP GRADIENTS BETWEEN 1 IN 14 AND STEEPER THAN 1 IN 20, AT INTERVALS THAT SHALL BE OBTAINED BY LINEAR INTERPOLATION. (D) WHERE RAMPS ARE CONSTRUCTED WITH A CHANGE IN DIRECTION, THE ANGLE OF APPROACH SHALL CREATE A 90 ANGLE TO THE LINE OF TRANSITION BETWEEN THE RAMP SURFACE AND THE LANDING SURFACE. (E) WHERE THE INTERSECTION IS AT THE PROPERTY BOUNDARY, THE RAMP SHALL BE SET BACK BY A MINIMUM OF 900 MM SO THAT THE HANDRAIL AND TGSIS DO NOT PROTRUDE INTO THE TRANSVERSE PATH.
RISE 185
BALUSTRADING BALUSTRADING WITHIN THE FIRE ISOLATED STAIRWELL TO BE CONSTRUCTED OF STEEL RAILINGS SPACED 450MM APART, EXTENDING UP 850MM FROM THE NOSING OF THE STAIRS, AND BEGINNING AT 120MM VERTICALLY FROM THE NOSING OF THE STAIRS. HANDRAILS HANDRAILS SERVICING FIRE ISOLATED STAIRWELLS TO BE CONNECTED TO THE TOPS OF BALUSTRADING, PROVIDING A TOTAL HEIGHT OF 900MM TO THE HANDRAIL/BALUSTRADE APPARATUS. HANDRAILS TO BE ELLIPTICAL IN SHAPE, WITH A VERTICAL CROSS SECTION OF 30MM AND A HORIZONTAL CROSS SECTION OF 50MM IN ACCORDANCE WITH CLAUSE 12 OF AS1428.1 BOTH ENDS OF THE HANDRAILS TO TURN 180 DEGREES TOWARDS THE GROUND, WITH 50MM CONSISTENT CLEARANCE FROM THE SUPPORTING WALL IN ACCORDANCE WITH CLAUSE 12 OF AS 1428.1 TACTILE INDICATORS TACTILE INDICATORS WILL BE PROVIDED 400MM FROM EVERY CHANGE OF SURFACE AND CHANGE OF SLOPE THROUGHOUT THE BASEMENT, GROUND FLOOR AND EXTERNAL AREAS OF THE BUILDING IN ACCORDANCE WITH SECTION 9 OF AS1428.1. FIRE ISOLATED STAIRS FIRE ISOLATED STAIRS ARE TO BE OF REINFORCED PRECAST CONCRETE, SUPPORTED BY THE WALLS OF THE SHAFT IN ACCORDANCE WITH D2.2 OF THE NCC2012. EACH NOSING WITHIN THE FIS TO BE PROVIDED FOR ITS ENTIRE WIDTH A 50MM SLIP RESISTANT CONTRASTING LUMINANCE STRIP (BLACK IN COLOR), SET BACK 10MM FROM THE EXTREMITY OF THE NOSING IN ACCORDANCE WITH CLAUSE 11.1 OF AS1428.1. NOSINGS TO BE ROUNDED AT THEIR EXTREMITY FOR A RADIUS OF 5MM BALUSTRADING AND HANDRAILS SERVICING FIS TO BE CONSTRUCTED OF STEEL. NO SERVICES (OTHER THAN THOSE USED BY THE FIRE BRIGADE) OR STORAGE TO BE LOCATED WITHIN THE FIRE ISOLATED STAIRWELLS IN ACCORDANCE WITH CLAUSE D2.7 OF THE NCC2012 EXTERNAL STAIRS AND RAMPS EXTERNAL STAIRS AND RAMPS PROVIDING ACCESS TO THE BUILDING TO BE CONSTRUCTED OF CAST IN SITU CONCRETE. NOSINGS TO BE ROUNDED AT THEIR EXTREMITY FOR A RADIUS OF 5MM
85.
85.
RISE 185
85.
291
17R AT 185.2mm
GOING
3150
77.
LANDING
7
185
1000
SFL
68.
69.
70.
71.
72.
73.
68.
69.
70.
71.
72.
61.
min. 10mm CONSTRUCTION GAP REINFORCEMENT WITH 25mm COVER AND BARS IN ACCORDANCE TO DETAILS SPECIFICTAIONS
288
185
68.
RISE 185
291
17R AT 185.2mm
GOING
3150
LANDING
GOING
TGSIS SHALL BE INSTALLED IN ACCORDANCE WITH AS 1428.4.1. (F) WHERE THE INTERSECTION IS AT AN INTERNAL CORRIDOR, THE RAMP SHALL BE SET BACK BY A MINIMUM OF 400 MM SO THAT THE HANDRAIL DOES NOT PROTRUDE INTO THE TRANSVERSE PATH OF TRAVEL. (G) THE HANDRAIL SHALL EXTEND A MINIMUM OF 300 MM HORIZONTALLY PAST THE TRANSITION POINT AT THE TOP AND BOTTOM OF THE RAMP EXCEPT WHERE THE INNER HANDRAIL IS CONTINUOUS AT AN INTERMEDIATE LANDING.
SFL
51.
52.
53.
54.
55.
56.
51. POWDER COATED HANDRAIL/BALUSTRADE TO STAIR AND LANDINGS 1000min. ABOVE FINISHED FLOOR LEVEL. 850min ABOVE NOSE TREAD
52.
53.
54.
55.
56.
51.
291
17R AT 185.2mm
3150
GOING
LANDING
185
RISE
185
9
S04
185
SFL
34.
35.
36.
37.
1000
38.
39.
REINFORCED CONCRETE STAIR AND LANDING TO STRUCTURAL ENGINNEERS DRAWING AND DETAILS
34.
35.
36.
37.
38.
39.
185
2460 34. 26. LANDING 25. 24 23. 22. 21. 20. 19. 18.
185
1200 1100
1200 1100
RISE
185
291
17R AT 185.2mm
GOING
3150
26.
185
5 S04
SFL
17.
18.
19.
20.
1000
21.
22.
1230
17.
18.
19.
20.
21.
REINFORCED CONCRETE STAIR AND LANDINGS TO STRUCTURAL ENGINEERS DRAWINGS AND DETAILS WIDTH OF WALKWAY/OPENING
291
17R AT 185.2mm
GOING
360
3150
SFL
1.
2.
3.
1000
4.
1.
2.
3.
4.
1740
5.
6.
5.
6.
7
1280
1 S04
1
S04
STAIR SECTION
1 : 50
3
S04
5
S04
STAIR SECTION 2
1 : 50
4
S04
8
S04
3
WALKWAY MAXIMUM 1:20 16200 KERB 1200 LANDING 7500 1:14 GRADIENT max 1200 LANDING 7500 1:14 GRADIENT max 2120 1200mm MIN LANDING 300 TURN HANDRAIL THROUGH A TOTAL OF 180 DEGREES OR RETURN FULLY TO END POST OR WALL FACE 7500 1:14 max GRADIENT 1200 LANDING
4
7500 1:14 max GRADIENT
540
7.
8.
7.
8.
370
9.
9.
9. LANDING 8. 7. 6. 5. 4. 3. 2. 1.
185
RISE
185
50
100
170
185
190
5
2120 1200min LANDING
1040
UP
DN
UP
1000
150
NGL
TRANSITION TRANSITION
, S R O T A C I D N I E L I T C A T
7
S04
RAMP PLAN
1 : 50
6
S04
RAMP SECTION
1 : 50
No.
Description
Date
ADDRESS: CLIENT:
S04
20/11/2013 2:46:31 PM
STUDENT ACCOMMODATION
9
REINFORCED 1800mm HIGH CONCRETE PARAPET WALL PROVIDE LYSAGHT TRIMDEK COLORBOND STEEL CAPPING AND FLASHING TO TOP OF ALL PARAPET WALLS IN ACC. TO MANUFACTURERS SPECIFICATIONS. 1:4 SLOP WATERPROOFING MEMBRANE
8
20mm VIRIDIAN TRAFFICAL LOW E TRIANGULAR GLASS ROOF PANELS @ 10 DEGREE PITCH. WATERPROOFING AND TANKING TO ENG. SPECIFICATIONS AND DRAWINGS OPERABLE ALUMINIUM HORIZONTAL LOUVERS BOUNDED TO 75mm x 75mm STEEL COLUMNS @ 1600mm c/c WATERPROOFING/TANKING IN ACCORDANCE TO ENG. SPECS AND DETAILS
75
8
GREEN ROOF PLANTS (min 90% SOIL COVERAGE) 400mm W x 160mm D BOX GUTTER WITH GRAVEL EDGING @ 1:200 FALL TO 150dia DOWNPIPES. CONNECT TO STORM WATER SYSTEM AS PER ENG. DETAILS TO THE SATISFACTION OF LOCAL AUTHORITIES. COURSE SAND AND ORGANIC CONTENT TO ENGINEERS SPECIFICATIONS. MOISTURE PORTAL LITE MODULE DRAIN OUTLET OPENINGS POLYPROPYLENE SLIP SHEET 40mm min WATERPROOFING MEMBRANE INSULATION INSULATION ADHESIVE OPERABLE ALUMINIUM HORIZONTAL LOUVERS BOUNDED TO 75mm x 75mm STEEL COLUMNS @ 1600mm c/c WATERPROOFING/TANKING IN ACCORDANCE TO ENG. SPECS AND DETAILS
250 30
250mm x 150mm CONCRETE BUND. WITH FIXED STEEL PLATE TO ENGINEERS DRAWINGS AND DETAILS.
SUSPENDED REINFORCED CONCRETE ROOF SLAB AND BEAM. THREADED TIE BAR SCREWED INTO CAST IN FURRULLES REFER TO STRUCTURAL ENGINEERS DAWINGS DETAILS TYP.
300mm X 400mm REINFORCED CONCRETE TRANSFER BEAM TO ENGINEERS DRAWINGS AND DETAILS.
135mm X 32mm BLACKBUTT HARDWOOD TIMBER DECKING @ 2 DEGREES SLOPE. WATERPROOFING AND TANKING TO ENGINEERS SPECIFICATIONS AND DETAILS.
150
2
S05
300mm X 400mm REINFORCED CONCRETE TRANSFER BEAM TO ENGINEERS DRAWINGS AND DETAILS.
135mm X 32mm BLACKBUTT HARDWOOD TIMBER DECKING @ 2 DEGREES SLOPE. WATERPROOFING AND TANKING TO ENGINEERS SPECIFICATIONS AND DETAILS.
250mm x 150mm CONCRETE BUND WITH M16 BOLT CAGE FIXED STEEL PLATE TO ENGINEERS DRAWINGS AND DETAILS.
1
S05
2
S05
5000
STEEL FRAME SYSTEM TO ENGINEERS DRAWINGS AND DETAILS 20mm VIRIDIAN TRAFFICAL LOW E TRIANGULAR GLASS ROOF PANELS @ 10 DEGREE PITCH. WATERPROOFING AND TANKING TO ENG. SPECIFICATIONS AND DRAWINGS. 20mm VIRIDIAN TRAFFICAL LOW E TRIANGULAR GLASS ROOF PANELS @ 10 DEGREE PITCH. WATERPROOFING AND TANKING TO ENG. SPECIFICATIONS AND DRAWINGS. 60mm M.S HOT DIP GALV.STEEL PLATE 75 x 75m X 8mm SHS
OPERABLE ALUMINIUM HORIZONTAL LOUVERS BOUNDED TO 75mm x 75mm STEEL COLUMNS @ 1600mm c/c WATERPROOFING/TANKING IN ACCORDANCE TO ENG. SPECS AND DETAILS
3
S05
5550
5 S05
SLOPE @ 10 DEGREES
250mm x 150mm CONCRETE BUND. WITH FIXED STEEL PLATE TO ENGINEERS DRAWINGS AND DETAILS.
OPERABLE ALUMINIUM HORIZONTAL LOUVERS BOUNDED TO 75mm x 75mm STEEL COLUMNS @ 1600mm c/c WATERPROOFING/TANKING IN ACCORDANCE TO ENG. SPECS AND DETAILS
SUSPENDED REINFORCED CONCRETE ROOF SLAB AND BEAM. THREADED TIE BAR SCREWED INTO CAST IN FURRULLES REFER TO STRUCTURAL ENGINEERS DAWINGS DETAILS TYP.
135mm X 32mm BLACKBUTT HARDWOOD TIMBER DECKING @ 2 DEGREES SLOPE. WATERPROOFING AND TANKING TO ENGINEERS SPECIFICATIONS AND DETAILS.
4
S05
5
S05
No.
Description
Date
ADDRESS: CLIENT:
S05
20/11/2013 2:46:32 PM
STUDENT ACCOMMODATION
1200
50mm X 50mm STEEL TRUSS SYSTEM PROVIDE BOLTED TEK SCEWS @ 2M SPACING 1500
9
150
100
25
PROVIDE 25mm MIN DRIP AT SOFFIT AND UNDER ALL HORIZONTAL PROJECTIONS
JOINT REINFORCED PRECAST CONCRETE PANEL TO MANUFACTURERS SPECIFICATION AND DETAILS BOLTED TEK SCREWS 4mm APOLIC SHEET
4
25
NOTE: SIZES OF QUIRKS AND RETURNS BASED ON JOINT WIDTHS IN ACCORDANCE WITH ENGINEERS SPECIFICATIONS AND DETAILS
RIVET
PRECAST CONCRETE TILT UP PANEL IN ACCORDANCE WITH ENGINEERS SPECIFICATIONS AND DETAILS RETURN
21 38
QUIRK MITERS
ALUMINIUM EXTRUSION
TEK SCREW
4
S06
150
PROVIDE 13mm POLYSILFIDE SEALANT TO JOINT WIDTH WITH A min DEPTH OF 6mm
13
BACKER ROD
2
S06
1
S06
150
9
REINFORCED 1800mm HIGH CONCRETE PARAPET WALL PROVIDE LYSAGHT TRIMDEK COLORBOND STEEL CAPPING AND FLASHING TO TOP OF ALL PARAPET WALLS IN ACC. TO MANUFACTURERS SPECIFICATIONS. 1:4 SLOP WATERPROOFING MEMBRANE
6
S06
400mm W x 160mm D BOX GUTTER WITH GRAVEL EDGING @ 1:200 FALL TO 150dia DOWNPIPES. CONNECT TO STORM WATER SYSTEM AS PER ENG. DETAILS TO THE SATISFACTION OF LOCAL AUTHORITIES. 8mm FIRELITE PLUS LAMINATED PREMIUM GRADE CERAMIC GLASS CURTAIN WALL OR SIMILAR. TO BE FIRE RATED AND IMPACT SAFETY RATED WITH HOLLOW METAL STEEL FRAME IN ACC.TO SELECTED MANUF' SPECIFICATIONS AND DETAILS. PROVIDE DRENCHING SYSTEM (TYPE B CONSTRUCTION) NOTE: MULLION TO BE ANCHORED TO BUILDING STRUCTURE AND SPANDREL PANELS TO BE SUCURED WITH PRESSURE PLATES IN ACCORDANCE WITH ENGINEERS SPECIFICATION AND DETAILS. PROVIDE 14.8mm THERMAL BREAK. FRAME TO BE FLUOROCARBON COATED.
400 300
13
GLASS GLAZING GLAZING TAPE SNAP COVER THERMAL ISOLATOR SEALANT AND BACKER ROD NOTE: ALL WINDOWS SHALL BE COMPLIANT WITH AS2047, GLAZED IN ACCORDANCE WITH AS1288 AND INSTALLED TO THE MANUFACTURERS RECOMMENDATIONS AND DETAILS. ALL SURFACE FINISHING SHALL BE IN ACCORDANCE WITH AS1231 (ANODISING) AND/OR AS3715 (POWDER COATING). NOTE: JOINTS TO BE RECESSED WITH A REVEAL OR CHAMFER AND TO BE LOCATED AT THE MAXIMIUM PANEL THICKNESS
7
S06
5
S06
8
S06
No.
Description
Date
ADDRESS: CLIENT:
S06
20/11/2013 2:46:33 PM
150
TYP.PRECAST JOINTS
1:5
STUDENT ACCOMMODATION
GENERAL NOTES
DO NOT SCALE DRAWINGS. USE WRITTEN DIMENSIONS ONLY. THE OWNER/BUILDER, SUB CONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS, SETBACKS & SPECIFICATIONS PRIOR TO COMMENCING ANY WORKS OR ORDERING MATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILIDNG WORKS CONFORM TO BUILDING CODE OF AUSTRALIA, AS CODES (CURRENT EDITIONS) BUILDING REGULATIONS, LOCAL BY LAW & TOWN PLANNING REQUIREMENTS. REPORT ALL DISCREPANCIES TO THIS OFFICE FOR CLARIFCATION. BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE STABILITY OF NEW AND EXISTING STRUCTURES DURING ALL WORKS. BUILDER TO ENSURE FOR THE GENERAL WATER TIGHTNESS OF ALL NEW AND EXISTING WORKS. 1. THESE DRAWINGS SHALL BE READ IN CONJUCTION WITH ALL ARCHITECTURAL AND OTHER CONSULTANTS DRAWINGS AND SPECIFICATIONS AND WITH SUCH WRITTEN INSTRUCTION AS MAY BE ISSUED DURING THE COURSE OF THE CONTRACT. ALL DESCREPANCIES SHALL BE REFERRED TO THE ARCHITECT FOR DECISION BEFORE PROCEDING WITH THE WORK. 2. ALL DIMENSIONS RELEVANT TO SETTING OUT AND OFF-SITE WORK SHALL BE VERIFIED BY THE CONTRACTOR BEFORE CONSTRUCTION AND FABRICATION IS COMMENCED. THE ENGINEER'S DRAWINGS SHALL NOT BE SCALED. 3. DURING CONSTRUCTION THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE STRUCTURE IN AN STABLE CONDITION AND ENSURING NO PART SHALL BE OVERSTRESSED UNDER CONSTRUCTION ACTIVITIES. 4. WORKMANSHIP AND MATERIALS ARE TO BE IN ACCORDANCE WITH THE RELEVANT CURRENT NCC CODES AND AS STANDARDS INCLUDING ALL AMENDMENTS AND THE LOCAL AUTHORITIES EXCEPT WHERE VARIED BY THE CONTRACT DOCUMENTS. 5. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS STATED OTHERWISE ALL LEVELS ARE EXPRESSED IN METERS. 6. THE STRUCTURAL WORK SHOWN ON THESE DRAWINGS HAS BEEN DESIGNED FOR THE FOLLOWING LIVE LOADS AREA ROOF FLOOR PASSAGEWAYS BALCONIES 7. IF YOU ARE IN DOUBT ASK LIVE LOAD kPa .25 kPa 2 kPa 4 kPa 4 kPa
STEEL
STEEL REINFORCEMENT ALL STRUCTURAL REINFORCEMENT SHALL COMPLY WITH AS 3850 REINFORCEMENT MUST COMPLY WITH AS 1302 FOR REINFORCEMENT BAR AND AS 1304 FOR FABRIC REINFORCEMENT. 1.THE STEEL REINFORCEMENT FOR ALL CONCRETE WALL PANELS SHALL BE DESIGNED TO RESIST HANDLING, INSTALLATION, AND IN-SERVICE LOADS TO CONTROL CRACKING AND SHRINKAGE STRESSES. 2. INSERTS AND ASSOCIATED LIFTING DEVICES MUST COMPLY WITH AUSTRALIAN STANDARD AS 3850. 3. ALL STEEL UNLESS OTHERWISE NOTED TO BE GRADE 304-316 STAINLESS STEEL. 4. UNLESS OTHERWISE SPECIFIED ALL STEEL BE PAINTED ONE SHOP COAT OF APPROVED ZINC RICH PRIMER
FOUNDATION
STIFFINED RAFT SLAB AND FOOTINGS TO BE CONSTRUCTED IN ACCORDANCE WITH ENGINEERS SPECIFICATION AND DRAWINGS IN CONJUNCTION WITH ENGINEERS SOIL TEST REPORT. ALL EARTHWORKS SHALL BE CARRIED OUT IN ACCORDANCE WITH THE CEMP REPORT. SITE CLASSIFICATION: THE SITE IS CLASSIFIED IN ACCORDANCE WITH SECTION 2 FROM AS2870 1996 RESIDENTIAL SLABS AND FOOTINGS CONSTRUCTION. SOIL CLASSIFICATION 300MM TO 500MM OF GREY/ORANGE FILL (MIX OF SILTY SAND AND SILTY CLAY) OVERLYING 500MM TO 600MM OF GREY SILTY SAND OVERLYING ORANGE/GREY/RED SILTY CLAY CLASS M (MODERATELY REACTIVE SITE). IN ACCORDANCE WITH ENGINEERS SOIL TEST REPORT EARTH WORKS 1. NO UNCONTROLLED FILL GREATER THAN 600MM FOR SAND AND 300MM FOR OTHER MATERIAL SHOULD BE PLACED. THE RELEVANT RESPONSIBLE GROUP GEOCORE SHOULD BE NOTIFIED AND SITE TO BE REASSESSED AND REVIEWED AND AMENDED. MOVEMENT OF SOIL TREES FROM WITHIN OR AROUND THE BUILDING ENVELOPE SHOULD BE REMOVED AS SOON AS POSSIBLE TO ALLOW THE TIME NEEDED FOR THE SUBSOILS TO REGAIN AND STABILISE ITS MOISTURE CONTENT. LEVELS DESIGN LEVELS SHOWN ARE ARBITRARY DATUM AND ARE TO BE USED AS A GUIDE ONLY. OWNER/BUILDER TO CHECK AND VERIFY ON SITE PRIORTO ANY WORK DONE. ALL LEVELS ON DRAWINGS ARE NOMINAL AND MAY ADJUST DUE TO SITE CONDITIONS UP TO 50MM EITHER WAY.
BUILDING CLASS
CLASS (2) A BUILDING CONTAINING TWO OR MORE SOLE - OCCUPANCY UNITS EACH BEING A SEPERATE DWELLING
WALLS
1. ALL EXTERNAL STRUCTURAL ELEMENTS WILL BE CONSTRUCTED EITHER WHOLLY OF CONCRETE OR STEEL REINFORCED CONCRETE. NO EXTERNAL STRUCTURAL ELEMENTS ARE PERMITTED TO BE CONSTRUCTED OF A COMBUSTIBLE MATERIAL IN ACCORDANCE WITH SPECIFICATION C1.14.1(B) OF THE NCC2012 2. ALL INTERNAL STRUCTURAL ELEMENTS WILL BE CONSTRUCTED OF STEEL REINFORCED CONCRETE. NONLOADBEARING INTERNAL WALLS WHICH SEPARATE SOLE OCCUPANCY UNITS (SOUS) WILL BE CONSTRUCTED OF CSR046 FIRE RATED LIGHTWEIGHT WALLING. 3. WALLS WITHIN SOUS WILL BE CONSTRUCTED OF CSR606 STANDARD LIGHTWEIGHT WALLING. 4. NO INTERNAL COMMON WALLS ARE TO BE PERMITTED TO BE CONSTRUCTED OF COMBUSTIBLE MATERIAL IN ACCORDANCE WITH SPECIFICATION C1.14.1(B) OF THE NCC2012 INTERNAL LIGHT WEIGHT WALLS TO BE TESTED IN ACCORDANCE WITH SPECIFICATION C1.83.4 OF THE NCC2012 5.ALL LIGHTWEIGHT WALLS WHICH ARE REQUIRED TO HAVE AN FRL (SEPARATING EVERY SECOND SOLE OCCUPANCY UNIT) MUST BE TESTED IN ACCORDANCE WITH SPECIFICATION C1.83.4 OF THE NCC2012. 6. ALL LIGHTWEIGHT WALLS SEPARATING SOLE OCCUPANCY UNITS MUST HAVE AN RW+CTR OF NOT LESS THAN 50 IN ACCORDANCE WITH CLAUSE F5.5 OF THE NCC2012 FOR SOUND INSULATION RATING OF WALLS. 7. INTERNAL WALLS NOT REQUIRED TO HAVE AN FRL OR RW+CTR VALUE WILL BE 70MM STEEL STUD WALLS FLOOR COVERINGS 1. ALL FLOOR COVERINGS SERVICING FIRE ISOLATED EXITS AND LIFT CARS INCLUDING COATINGS AND FINISHES MUST HAVE A CRITICAL RADIANT FLUX (CRF) OF NOT LESS THAN 2.2. 2. ALL OTHER FLOOR COVERINGS INCLUDING COATINGS AND FINISHED MUST HAVE A CRF OF NOT LESS THAN 1.2 IN ACCORDANCE WITH SPECIFICATION C1.10TABLE 2 FOR CLASS 2 BUILDINGS. WALL COVERINGS 1. ALL WALL COVERINGS, LININGS AND COATINGS WITHIN FIRE ISOLATED EXITS TO BE OF A MATERIAL WHICH FALLS UNDER THE GROUP 1 CATEGORY IN ACCORDANCE WITH SPECIFICATION C1.104. 2. ALL WALL COVERINGS, LININGS AND COATINGS WITHIN THE LIFT CAR TO BE OF A MATERIAL WHICH FALLS UNDER THE GROUP 1 OR GROUP 2 CATEGORIES IN ACCORDANCE WITH SPECIFICATION C1.104. 3. ALL OTHER WALL COVERINGS, LININGS AND COATINGS TO BE OF A MATERIAL WHICH FALLS UNDER THE GROUP 1, GROUP 2 OR GROUP 3 CATEGORIES IN ACCORDANCE WITH SPECIFICATION C1.104
EXPOSURE CONDITION
FULLY ENCLOSED INSIDE A BUILDING: INSIDE A BUILDING SUBJECTED TO REPEATED WETTING AND DRYING: ABOVE GROUND IN EXTERIOR ENVIRONMENT IN AN INDUSTRIAL ZONE: UP TO 1 KM FROM COASTLINE, BUT NOT IN A TIDAL OR SPRAY ZONE: IN CONTACT WITH GROUND
50
NO
50
NO
32 40 25
40 45 30
SERVICE PENETRATIONS
PENETRATIONS THROUGH STRUCTURAL ELEMENTS LOCATION 1. SERVICE PENETRATIONS THROUGH FIRE RATED BUILDING ELEMENTS FOR STEEL PIPEWORK WILL BE LOCATED NOT LESS THAN 200MM FROM ANY OTHER PENETRATION IN ACCORDANCE WITH NCC2012 SPECIFICATION C3.15 CLAUSE 3. 2. WHERE POSSIBLE, PENETRATIONS THROUGH STRUCTURAL ELEMENTS SHOULD BE SPACED EVENLY AS TO ENSURE CONTINUAL STRUCTURAL ADEQUACY OF THE STRUCTURE.
1. ALL INSERTS SHOULD BE VISUALLY INSPECTED TO ENSURE THAT THE TYPES AND STRENGTHS ARE CORRECT AND IN ACCORDANCE WITH PANEL SHOP DRAWINGS. 2. SHEAR REINFORCEMENT SHALL BE CORRECTLY PLACED FOR EACH INSERT AND CORRECTLY POSITIONED IN ACCORDANCE WITH PANEL SHOP DRAWINGS. 3. ONLY PROPRIETARY INSERTS AND FERRULES RATED FOR THE PARTICULAR APPLICATION SHOULD BE USED. CONCRETE PANELS 1. CONCRETE PANELS TO COMPLY WITH DESIGN REQUIREMENTS AND WITH AS 1379: THE SPECIFICATION AND MANUFACTURE OF CONCRETE. 2. CONCRETE SUPPLIER TO BE CERTIFIED IN ACCORDANCE WITH AS 1379
ADDITIONAL NOTES
THESE DRAWINGS TO BE READ IN CONJUCTION WITH SOIL REPORT. SERVICES DRAINS, DOWNPIPES, GUTTERING AND SERVICE PIPING MUST BE INSTALLED AND MAINTAINED CAREFULLY TO ENSURE NO LEAKAGE OR BLOCKAGE OCCURES THAT WILL AFFECT THE FOOTONG SYSTEM. STORM WATER DRAINS UNDER THE FOOTING SYSTEM ARE NOT PERMITTED AND IF SHOWN ON THE ARCHITECTURAL DRAWINGS AND/OR ANY OTHER DOCUMENTATION THEY ARE TO BE AMENDED AND REDIRECTED AWAY FROM THE FOOTING. VAPOUR BARRIERS VAPOUR BARRIES OR DAMP -PROOFING MEMBRANES ARE TO COMPLY AND BE INSTALLED AS PER THE REQUIREMENTS OF AS 2870.
3. WHERE A SERVICE PENETRATES A HOLLOW WALL, THE PENETRATION IS TO BE STEEL FRAMED AND PACKED WITH CONCRETE FIRE STOPPER FOR A MINIMUM OF 25MM AROUND THE ENTIRE PENETRATION. 4. WHERE A SERVICE PENETRATES A SOLID WALL, THE PENETRATION MUST BE PROVIDED WITH CONCRETE FIRE STOPPER AROUND THE PIPE TO ENSURE NO GAPS. METAL PENETRATIONS 1. FIRE STOPPERS PROTECTING STEEL PIPEWORK WILL BE CONCRETE COPPER PIPEWORK WILL BE A MINIMUM 1MM THICK IN ACCORDANCE WITH AS1432 2. ALL METAL PIPEWORK TO BE TESTED IN ACCORDANCE WITH SECTION 10 OF AS1530.4 METAL PIPEWORK SERVICING THE HOT WATER WILL BE INSULATED, AND TESTED IN ACCORDANCE WITH AS1530.4. 3. FOR LAGGED PIPEWORK (CLAUSE 10.7) UNDER NO CIRCUMSTANCE SHOULD A SERVICE PENETRATION AFFECT THE FRL OF A STRUCTURAL ELEMENT. ALL METAL PIPEWORK PENETRATION TESTING TO BE CONDUCTED AND DOCUMENTED IN ACCORDANCE WITH AS4072.1 (CLAUSE 4.4) AND AS1530.1 (SECTION 10) PVCU PENETRATIONS 1.NO PVC SERVICE WILL PENETRATE A WALL LESS THAN 200MM FROM A METAL SERVICE OR A SERVICE FIRE STOPPERS PROTECTING PVCU PIPEWORK WILL BE CONCRETE. 2. ALL ELECTRICAL SERVICES TO BE CONSTITUTED OF COPPER CONDUCTORS WITHIN A LAGGED PVCU CONDUIT IN ACCORDANCE WITH CLAUSE 4.6 AND APPENDIX A OF AS4072.1, AND ARE TO BE INSTALLED IN ACCORDANCE WITHAS1530.4 APPENDIX D. 3.PVCU PIPEWORK SERVICING KITCHEN SINKS, LAUNDRY TROUGHS, WATER CLOSETS, BASINS, PLUMBING STACKS AND THE LIKE ARE TO BE TESTED IN ACCORDANCE WITH CLAUSE 10.11.5 OF AS1530.4 FOR FIRE RESISTANCE.
HARD STAND
CONSTRUCTION DIMENSIONS THE HARDSTAND WILL BE NOT LESS THAN 2.6 X 5.4 METERS TO PROVIDE ADEQUATE SPACE FOR FIRE BRIGADE PUMPING AND CONNECTION TO THE EXTERNAL FIRE HYDRANT AND BOOSTER ASSEMBLY. BUILDING MATERIAL 1. THE HARDSTAND WILL BE CONSTRUCTED AS A FLAT SURFACE (NO MORE THAN 4 DEGREES) IN ACCORDANCE WITH THE MFB PUBLICATION GL13 2003. 2. THE HARDSTAND WILL BE CONSTRUCTED OF 150MM CONCRETE PAVERS DESIGNED TO WITHSTAND AN EQUALLY DISTRIBUTED LOAD OF 7KPA TO ENSURE A STABLE FOOTING FOR THE PUMPING APPLIANCE IN ACCORDANCE WITH THE MFB PUBLICATION GL13 2003. A B C D
CONCRETE
CONCRETE STRUCTURES SHALL BE DESIGNED FOR ULTIMATE STRENGTH AND SERVICEABILITY LIMIT STATES IN ACCORDANCE WITH THE GENERAL PRINCIPLES AND PROCEDURES FOR DESIGN AS SET OUT IN AS/NZS 1170.0 AND THE SPECIFIC REQUIREMENTS OF CLAUSES 2.2 AND 2.3. DESIGN CHECKS SHALL BE CARRIED OUT FOR ALL APPROPRIATE SERVICE CONDITIONS TO ENSURE THE STRUCTURE WILL PERFORM IN A MANNER APPROPRIATE FOR ITS INTENDED FUNCTION AND PURPOSE. 1. ALL REINFORCEMENT SHALL BE SUPPORTED IN IT'S CORRECT POSITION, APPROVED BAR CHAIRS, SPACES OR SUPPORT BARS. 2. TWO LAYERS OF MALTHOID IS TO SEPERATE CONCRETE FROM SUPPORTING BRICKWORK OR BLOCKWORK. 3. CURING TO BE MOIST CURE FOR 14 DAYS. 4. POUR ONLY BETWEEN 5deg C AND 35deg C 5. ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS 3600. 6. MINIMUM COVER (25mm) TO ALL REINFORCEMENT UNLESS OTHERWISE SHOWN. 7. SIZES OF CONCRETE ELEMENTS DO NOT INCLUDE SLAB THICKNESS OF APPLIED FINISH 8. BEAM DEPTHS ARE WRITTEN FIRST AND INCLUDE SLAB THICKNESS 9. NO HOLES, CHASES OR EMBEDMENT OF PIPES OTHER THAN THOSE SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE MADE IN CONCRETE MEMBERS WITHOUT PRIOR APPROVAL OF THE ENGINEER. 10. CONSTRUCTION JOINTS SHALL PROPERLY FORMED AND USED ONLY WHERE SHOWN OR SPECIFICALLY APPROVED BY THE ENGINEER.
WALL LEGEND
WALL TYPE A : EXTERNAL LOAD BEARING WALLS <1.5mm FROM FSF (150mm TILT-UP PRECAST CONCRETE WALLS) WITH A REQUIRED FRL OF 90/90/90 WALL TYPE B : INTERNAL LOAD BEARING WALLS - FIRE ISOLATED STAIRS AND LIFT SHAFT (150mm TILT-UP CONCRETE WALLS WITH A REQUIRED FRL OF 90/90/90 WALL TYPE C : INTERNAL LOAD BEARING WALLS - ALL EXCEPT THOSE SPECIFIED ABOVE (150mm TILT-UP CONCRETE WALLS) WITH A REQUIRED FRL OF 60/60/60 WALL TYPE D : INTERNAL NON-LOAD BEARING WALLS SEPARATING SOLE OCCUPANCY UNITS (92mm STEEL STUD + FYRCHECK 16mm ON EACH SIDE + 6mm CEMINSEAL WALLBOARD ON EACH SIDE WITH A REQUIRED FRL OF 90/90/90 WALL TYPE E : INTERNAL NON-LOAD BEARING BATHROOM WALLS ( COMMON 70mm STEEL STUD WALLLS) 350dia CONTIGUOUS CON.PILE TO BOUNDARY 100mm SHOT CRETE TO FACE REFER TO STRUCTURAL ENGINEERS DRAWINGS AND DETAILS. PROVIDE APPROVED TANKING/EWATERPROOFING TO SELECTED EXTERNAL WALLS BELOW FINISHED GROUND IN ACCORDANCE WITH SELECTED MANUF'SPECIFICATIONS
E G
DEFLECTION HEAD TRACK 499 92mm x 50mm x 0.70 btm DEFLECTION HEAD TRACK
Sheet Name FOOTING LAYOUT NORTH - SOUTH SECTION EAST - WEST SECTION ROOF - WALL JUNCTION DETAIL TYP. STAIR SECTION AND DETAIL CLADDING & WALL DETAILS
Sheet List Drawn By HELEN MAISANO HELEN MAISANO HELEN MAISANO HELEN MAISANO HELEN MAISANO HELEN MAISANO
No.
Description
Date
ADDRESS: CLIENT:
S07
20/11/2013 2:46:33 PM
STUDENT ACCOMMODATION
GENERAL NOTES