Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Airwise: Air Purifier

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

www.waterwise.

com/airwise

SEE IT WORK

USE & CARE GUIDE

Airwise Air Purier

Small, Large and Multi-room Models

Made in USA

See important safeguards on pages 2 and 3


An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance instructions in the literature accompanying the appliance. A lightning bolt within an equilateral triangle is intended to alert user to risk of injury from electric shock.

IMPORTANT SAFEGUARDS
A person who has not read and understood all operating and safety instructions is not qualied to operate this appliance. When using this appliance, always adhere to basic safety precautions including: READ ALL INSTRUCTIONS BEFORE USE. 1. Use INDOORS on a dry, level, well-supported, stable surface. DO NOT use outdoors. 2. Keep out of reach of children. 3. 4. Plug Purier into a 120 volt electrical outlet only. This Purier has a polarized plug (one blade is wider than the other). To reduce the risk of electrical shock, the plug will t into a polarized outlet only one way. If the plug does not t fully into outlet, reverse plug. If it still does not t, contact a qualied electrician. DO NOT modify plug in any way. DO NOT operate with a damaged cord or plug, after a malfunction, or if the Purier has been damaged in any manner. Return to an autorized dealer or authorized service facility for examination, repair, or replacement.

5. If an extension cord must be used, its marked electrical rating should be at least as great as the electrical rating of the Purier. 6. DO NOT allow power cord or extension cord to hang over the edge of a counter or contact hot surfaces. DO NOT use Purier if cord is damaged or defective. 7. To protect against re, electrical shock, and injury to persons, DO NOT immerse power cord or Purier in water or liquid. 8. DO NOT place too near an edge of the supported surface where Purier can be bumped or pulled down on someone.

Airwise Air Purier Use & Care Guide

9.

This Purier requires no special care other than annual lamp module replacement. If servicing becomes necessary, please contact your auth- orized dealer or an authorized service facility. DO NOT attempt to repair yourself. There are NO user serviceable parts inside.

10. Unplug from wall outlet and allow to cool completely before changing the lamp module. 11. DO NOT use appliance for other than intended use. 12. DO NOT move Purier while it is operating. 13. DO NOT operate in a moving vehicle.

CAUTION
RISK OF ELECTRICAL SHOCK DO NOT OPEN

ATTENTION
CAUTION! TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE BOTTOM COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

WARNING
The Airwise Purier is not a medical device. DO NOT stop or alter any medical therapy programs or medications without the advice of your physician. People with pacemakers and other electronic support devices should consult their health-care provider before using this appliance.

SAVE THESE INSTRUCTIONS


Airwise Air Purier Use & Care Guide

Superoxide Ions Hydroxyl Radicals

Oxygen

Natural Humidity

Germicidal UV Light

Target Area

Target Area Photocatalytic Reaction

HOW IT WORKS
Airwise uses humidity from the air to create a photocatalytic reaction between the germicidal UV lamp and the multi-metallic and titanium dioxide coatings on the target area of the lamp module. This reaction produces hydroxyl radicals and superoxide ions. As they are emitted into the room they destroy microorganisms like bacteria and viruses and oxidize odors, fungi, mold, parasites, and toxic chemical gases. The Airwise purier also includes Wisepointe technology, a self-limiting negative ion generator. Negative ions are attracted to airborne positive ions such as dust, pollen, pet dander and smoke. This agglomeration of ions makes the particles heavier than air, thus settling them out of the breathing space.

INSTALLATION/OPERATION
Place the Purier on a at, level, stable surface in the room where you spend the most time or close to source of odor. For optimal performance, place the Purier higher up, such as on a tall piece of furniture. The Purier includes an extra long power cord to accommodate this optimal placement. To insure proper air ow, keep the appliance at least 4 inches away from wall. Plug Airwise into a standard 120 volt wall outlet only. Press On/Off switch to On position (see rear view diagram, page 5). Lamp module will illuminate. Airwise is most effective in treating open areas. A properly sized Purier will cause the air to smell clean and fresh. Performance may vary according to atmospheric and/or environmental conditions such as altitude, relative humidity, air movement, severity of existing odor, house design and square footage. If you still detect household odor after a few days, a larger size lamp module may be needed. If you notice a lingering, sterile, 4
Airwise Air Purier Use & Care Guide

metallic odor or experience burning eyes, a smaller size lamp module may be needed or the Purier may need to be moved to a larger room.

SPECIFICATIONS
MODEL
Small Large Multi-Room

MIN. TREATMENT AREA


150 SQ. FT. 350 SQ. FT. 750 SQ. FT.

MAX. TREATMENT AREA


350 SQ. FT. 750 SQ. FT. 1500 SQ. FT.

Ozone Output: Less than .04 ppm UV Output: 8 micro watt per sq. centimeter Ion Generation: Passive and active negative UV ions Electrical Rating: 120 Volt, 60 Hz, 12 Watts, .1 Amp Made in USA with UL Listed Parts On Off

Rear View

Power Cord with Polarized Plug

On/Off Switch

Lamp Module

Right Side View

DO NOT mistake the gold akes on the module for dirt or prior use. This multi-metallic coating acts as a catalyst in the production of superoxide ions. 5

Airwise Air Purier Use & Care Guide

Questions & Answers


Q: Does my Airwise need to run all the time? A: No. You can use your Airwise as needed; however, most owners run the Purier nonstop to continuously enhance the quality of their air. Q: Is there any maintenance required? A: No. Simply replace the lamp module once a year. Q: What about my clothes? Can I eliminate dry cleaning odors or smoke smell? A: Yes. Place Airwise in a closet with dry-cleaned or smoke-lled garments for one hour with the door closed. Q: Does the technology help with pet odor? A: Yes. It not only removes pet odors, but will drop pet dander out of the air. Q: Can my system be used for travel? A: Yes. Many owners have an additional small room lamp module which works great in hotel rooms and RVs.

Maintenance
The performance of the Purier will diminish with use. To maintain best treatment, the lamp module should be replaced after approximately 9000 hours of operation, or once per year if operated continuously.

CAUTION! Always be sure to unplug power cord from wall outlet and allow to cool completely before changing lamp module. Firmly grip lamp module and pull it out of the Purier. Install new lamp module by sliding it into Purier until it is ush with side of appliance (see right side view, page 5).

TrouBleshooting
If you suspect a problem, check the following: Purier is plugged in properly and turned on. The wall outlet is active. Lamp module correctly installed.

Airwise Air Purier Use & Care Guide

Caution! To reduce the risk of electrical shock, DO NOT remove bottom cover. No user serviceable parts inside. Refer servicing to qualied service personnel.

SERVICE
Contact qualied service personnel for repair if the troubleshooting tips fail.

WARRANTY
Your Purier has a three (3) year limited warranty from date of original purchase. Refer to page 8 for details. Complete and return warranty registration card within 20 days of purchase. See Warning/Rating Label on bottom of Purier for serial number.

WHERE TO USE
Homes & living areas Ofces & stores Water/re damaged areas Shoe repair stores New paint, wallpaper, paneling Odor cleanup Barbershops Doctors ofces Day care centers Smoking areas Hair & nail salons Hotel rooms High pollen environments New carpet & furniture Kitchens Attics Laundry rooms Basements Photo labs Sick buildings & ofces Hospitals, nursing homes Veterinary ofces, kennels Printing businesses Locker rooms Carpet showrooms New cabinetry

This product has been packaged in recycled material. Our goal is to provide the best possible packaging while ensuring the future of generations to

Airwise Air Purier Use & Care Guide

WARRANTY REGISTRATION CARD


Please ll out and return the enclosed registration card within twenty days of purchase. Returning this card will not affect warranty coverage, but may expedite the processing of a warranty claim. Returning this card is the only way to guarantee you will be notied of any issues that arise concerning this product. The additional information will also help us to develop new products that best meet your needs. Thank you!

OWNERS LIMITED WARRANTY


Airwise warrants, to the original purchaser, this product against defects in materials and workmanship excluding the replaceable lamp module, for a period of three (3) years from the date of purchase. The lamp module is warranted against defects in materials and workmanship for one (1) year prorated from the date of purchase. Defects or failures due to shipping/handling, improper use or maintenance, including abuse or neglect, normal wear, accidents, alterations or modications, or unauthorized repair are specically excluded from this warranty. No dealer, distributor, agent, representative, or other person is authorized to extend or expand this warranty. Airwise is not responsible or liable for personal injury, property damage, or incidental or consequential damages arising out of, or in connection with, the use or performance of the product or other damages with respect to loss of use, or costs of removal, installation, or reinstallation. Airwise will, at its option, replace or repair the defective part(s) without charge, provided they are returned, transportation prepaid by owner, to an authorized service facility or to the address below. Enclose a letter describing the problem, copy of dated proof of purchase, and your name, address and daytime telephone number. This limited warranty does not guarantee uninterrupted service. Repair or replacement as provided under this warranty is the exclusive remedy of the purchaser. This limited warranty is in lieu of all other warranties, expressed or implied, including, but not limited to, any implied warranty of merchantability or tness for a particular use or purpose. This warranty gives you specic legal rights and you may also have other rights which vary from state to state or province to province. Outside the United States, a different warranty may apply. For details, please contact your authorized Airwise distributor.

3608 Parkway Blvd Leesburg Florida 34748-9399 (352)787-5008 Fax (352)787-8123


2005 Airwise Printed in USA Form 2804 Rev 10/06

You might also like