Desalination
Desalination
Desalination
TA5
WATER TREATMENT PLANT
SECOND PASS RO
LIME STONE FILTER
MIXED BED RO
DM TANKS
SDI < 3
FIRST PASS RO
Flow 3300 Cum/Hr TDS 35000 ppm TSS 200 ppm Sp.Gr 1.03
SECOND PASS RO
LIME STONE FILTER
DM TANKS
Flow 150 Cum/Hr PH 6.8 7.2 Silica < 0.01 ppm Cond < 0.1 Microsiemens Na & CO2 Nil
F 30
F 20
F 60
TURBIDITY 200 NTU AT INLET FeCl 3 Coagulant dosage to remove TURBIDITY NaoCl dosage from ECP to remove ALGAE
TURBIDITY 50 NTU
Reject from Clarifier SLUDGE SUMP 200 CUM B/W from GSF
TO REJECT
To TA4
FILTERED WATER TANK TURBIDITY <2 NTU AT OUTLET OF PRE TREATMENT PLANT. NO CHEMICAL CHANGE
3 Nos Vertical pumps for GSF backwash & 3 Nos of Twin Lobe Blowers
PRE TREATMENT PROCESS STILLING CHAMBER NaOCl is added To remove ALGAE. FLASH MIXER FeCl3 Coagulant is added To remove TURBIDITY. FLOCULLATOR Coagulant aid (Polyelectrolyte) is added To remove COLLOIDAL SILICA. LAMELLA CLARIFIER To filter TURBIDITY upto 50 NTU. GSF To filter TURBIDITY TO < 2 NTU.
Antioxident SMBS to Remove Free Cl2 Antiscalant SHMP to Remove all Carbonates alkalinity
UF B/W
REJECT TANK Acid/ Lye for PH correction (6 to 7) RO CARTRIDGE FILTER 3 Nos Service water & Lime stone feed
To Reject
*SMBS - Free Cl2. *SHMP - Carbonates alkalinity. *Acid/ Lye for PH correction.
2nd Pass Cartridge Filter 3 Nos 2nd Pass DG Feed Pump Reject to Permeate cum B/W Tank
DM WATER TO CST
2 Nos. DM TANK
MEMBERANES/CARTRIDGES
SYSTEM UF MEMBERANES FIRST PASS CARTRIDGE FIRST PASS MEMBERANES SECOND PASS CARTRIDGE SECOND PASS MEMBERANES
PROCESS PARAMETERS
PROCESS QUANTITY in CUM/HR TDS in ppm TSS in NTU REMARKS
INTAKE WATER After Lamella Clarifier After GSF After UF Skid After I Pass RO After II Pass RO
3300
35000
200 50
2 NIL PH 6.8 to 7.2, Silica < 0.01ppm Cond < 0.1 Microsiemens, Na & CO2 - NIL As per IS 10500 TDS 500 ppm, TSS NIL, Ca 75 ppm, Mg 50 ppm, Sulphite & Chlorides 200 ppm each, PH 7 to 8.5, CO2 NIL.
NIL
3 Nos. Lime Stone Filters First pass RO Permeate Water Storage Tank
To REJECT