Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Flowlink Industries Pvt. LTD

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 1

FLOWLINK INDUSTRIES PVT. LTD.

141, Udyog Vihar Phase-I


GURGAON - 122016
FINTUBE EXCHANGER DATA SHEET
E-5458/07/ED1N

30-Jan-07

CUSTOMER:TAURIAN ENGINEERING PVT. LTD.


ADDRESS:RORKEE
SERVICE OF UNIT
AIR / HYDRAULIC OIL COOLER
APPROX OVERALL SIZE: 600 mm Lg. X 600 mm Ht. X 800 mm Depth.

FLUID CIRCULATED
TOTAL FLUID ENTG. Kg/Hr
* STEAM PRESS. Kg/sq.Cm a
SP. GRAVITY
SP. VISCOSITY C.P.
SP. HEAT/L.HEAT
TH. COND. KCal/HrMdegC

PERFORMANCE OF ONE UNIT


Shell Side
AIR
2169
#N/A
0.00113
0.021
0.24
0.0294

TEMP. IN deg.C
TEMP. OUT deg.C
PASSES PER SHELL
PR. DROP Kg/Sq.Cm
FOULING HrMSqDegC/KCal
HEAT EXCHANGED K.Cal/Hr
METD (CORRECTED) deg.c
* IF APPLICABLE

Tube Side
HYDRAULIC OIL
4050
#N/A
0.9
30
0.50
0.1103

35
39.71

60
58.77

1
0.0012

3
0.6811

0.00102
2500
21.94

(Overall)

CONSTRUCTION OF ONE SHELL


DESIGN PR. Kg/SqCm
TEST PR. Kg/SqCm
DESIGN TEMP. deg.C

ATM
#N/A
100

10
15
100

TUBES: Cu., FINS: Al.,


TUBE PITCH Triangular
SHELL & CASING: C.S.
----------------------------------------- ----------------------------------------- -----------------------------------------