API STD 676-2009 - Hoja de Requisición
API STD 676-2009 - Hoja de Requisición
API STD 676-2009 - Hoja de Requisición
BY REV/APPR JOB NO. PAGE 1 OF 3 ITEM NO. REQ'N NO. PO NO. FOR
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61
PURCHASE
NOTE:
BY MANUFACTURER GENERAL
BY MANUFACTURER OR PURCHASER
NO. MOTORS DRIVEN MOTOR ITEM NO'S DRIVER PROVIDED BY GEAR MOUNTED BY MOTOR DATA SHEET NO.
OTHER DRIVER TYPE PUMP ITEM NO'S DRIVER ITEM NO'S GEAR PROVIDED BY MOTOR MOUNTED BY DRIVER DATA SHEET NO.
PUMP ITEM NO'S GEAR ITEM NO'S MOTOR PROVIDED BY DRIVER MOUNTED BY GEAR DATA SHEET NO.
OPERATING CONDITIONS MIN NORMAL RATED MAX (1) CAPACITY: (m3/h) OTHER OPER CONDITIONS: (m3/h) DISCHARGE PRESSURE: (barG) SUCTION PRESSURE : (barG) DIFFERENTIAL PRESSURE: (bar) NPSH AVAILABLE (m) NPIP AVAILABLE (barA) NPSHAa / NPIP DATUM: C.L. SUCTION NOZZLE TOP OF FOUNDATION DUTY CYCLE CONTINUOUS INTERMITTENT (1) Maximum - mechanical design
PUMPED FLUID TYPE OR NAME OF PUMPED FLUID MIN NORMAL RATED TEMPERATURE: (C) VAPOR PRESS.: (barA) RELATIVE DENSITY (SG): VISCOSITY: (mPa-s) SPECIFIC HEAT Cp (kJ/kg C) CORROSIVE/EROSIVE AGENTS DESCRIPTION EROSIVE CORROSIVE CHLORIDE CONCENTRATION (ppm) H2S CONCENTRATION (ppm) FLUID HAZARDOUS FLAMMABLE OTHER GAS ENTRAINED SLUG FLOW % BY VOLUME or GVF SOLIDS PARTICLE SIZE DISTRIBUTION & MIN/MAX () SHAPE CONCENTRATION HARDNESS
PERFORMANCE RATED CAPACITY (m3/h) NPSHa / NPIP REQUIRED (m) (barA) RATED SPEED (rpm) RATED VOLUMETRIC EFFICIENCY (%) RATED PUMP EFFICIENCY (%) REQUIRED POWER @ MAXIMUM VISCOSITY (BkW) REQUIRED POWER @ PRESSURE LIMITING VAL (BkW) REQUIRED POWER @ RATED CONDITION (BkW) MAXIMUM ALLOWABLE SPEED (rpm)
SITE AND UTILITY DATA LOCATION INDOOR OUTDOOR HEATED UNHEATED UNDER ROOF ELECTRICAL AREA CLASS GROUP DIV ZONE GROUP TEMP CLASS WINTERIZATION REQD TROPICALIZATION REQD SITE DATA ELEVATION (C) BAROMETER (barA) RANGE OF AMBIENT TEMPS:MIN/MAX / (C) UNUSUAL CONDITIONS DUST FUMES SALT ATMOSPHERE OTHER UTILITY CONDITIONS ELECTRICITY DRIVERS HEATING CONTROL SHUTDOWN VOLTAGE HERTZ PHASE COOLING WATER INLET RETURN DESIGN MAX TEMP (C) MAX PRESS. (barG) MIN SOURCE INSTRUMENT AIR MAX MIN PRESSURE (barG)
CONSTRUCTION CONNECTIONS SUCTION SIZE DISCHARGE GLAND FLUSH DRAINS * VENTS * JACKET ANSI RATING FACING POSITION
* PIPE VENTS & DRAINS TO EDGE OF BASEPLATE PUMP TYPE INTERNAL GEAR TWIN-SCREW VANE LOBE EXTERNAL GEAR 3-SCREW PROGRESSING CAVITY ROTARY GEAR TYPE
APPLICABLE SPECIFICATIONS: API-676 POSITIVE DISPLACEMENT PUMPS - ROTARY GOVERNING SPECIFICATION (IF DIFFERENT) NACE MR0103 (6.13.2.13) NACE MR0175 OTHER
REMARKS:
ITEM NO.
OF
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57
CONSTRUCTION CASING MAX. ALLOWABLE CASING PRESS. (6.3.1): (barG) @ (C) MAXIMUM ALLOWABLE SUCTION PRESSURE: (barG) @ (C) HYDROSTATIC TEST PRESSURE - Suct I Disch: I (barG) ROTATING ELEMENTS ROTOR MOUNT BTWN. BEARINGS OVERHUNG TIMING GEARS YES NO TYPE BEARING TYPE: RADIAL THRUST BEARING NUMBER: RADIAL THRUST LUBRICATION TYPE: CONSTANT LEVEL OILERS PUMPED FLUID RING OIL OIL MIST EXTERNAL OIL FLOOD GREASE LUBRICANT Info (Visc, etc) MECHANICAL SEALS MANUFACTURER AND MODEL MANUFACTURER CODE API 682 AND DATA SHEETS API 682 SEAL FLUSH PLAN API 682 SEAL CODE
MIN DESIGN METAL TEMP (6.13.6.1) STATOR I LINER END PLATES ROTOR (S) VANES SHAFT SLEEVE (S) GLAND (S) BEARING HOUSING TIMING GEARS ELASTOMERS I GASKETS
(C) CASING
QA INSPECTION AND TEST SPECIAL MATERIAL TESTS (See design codes + weld + inspection sheet) LOW AMBIENT TEMP. MATERIALS TESTS (6.13.6.5) COMPLIANCE WITH INSPECTORS CHECK LIST CERTIFICATION OF MATERIALS (user to define affected components in remarks) SURFACE I SUBSURFACE EXAM'S (user to define affected components in remarks) RADIOGRAPHY ULTRASONIC MAGNETIC PARTICLE LIQUID PENETRANT COMPONENT PMI HARDNESS OF PARTS, WELDS & HEAT AFFECTED ZONES VENDOR SUBMIT TEST PROCEDURES (8.3.1.2) SUPPLIER TO KEEP REPAIR AND HT RECORDS (8.2.1.1) DRIVER TYPE NON-WIT WIT OBSERV SHOP INSPECTION (8.1) INDUCTION MOTOR STEAM TURBINE GEAR OTHER HYDROSTATIC (8.3.2) WITH WETTING AGENT PERFORMANCE (8.3.4) RETEST ON SEAL LEAKAGE NPSH I NPIP (8.3.7.1) DRIVE MECHANISM TRUE PEAK VELOCITY DATA COMPLETE UNIT TEST (8.3.7.2) SOUND LEVEL TEST (8.3.7.3) DIRECT-COUPLED ASD OTHER COUPLING MANUFACTURER CLEANLINESS PRIOR TO COUPLING TYPE FINAL ASSEMBLY (8.2.3.3) RATING (MAX TORQUE) MODEL SPACER LENGTH HIGH DISCHARGE PRESSURE @ PLV CHECK FOR CO-PLANAR AT MOUNTING PAD SURFACES (7.4.7) (IN) S.F. 1 HR MECHANICAL RUN TEST AFTER OIL TEMP STABLE (8.3.5.1) COUPLING BALANCED MANF STD AGMA 9000 CLASS 10 (7.2.3) COUPLING PER API 4 HR. MECH RUN AFTER 671 (7.2.4) OIL TEMP STABLE(8.3.5.2) AUXILIARY EQUIPMENT TEST (8.3.4.3) OTHER COUPLING HUB ATTACHMENT TEST WITH SUBSTITUTE SEAL (8.3.5.3) STRAIGHT KEYED TAPERED SUPPLIER SUBMIT TEST DATA WITHIN 24 HOURS INCLUDE PLOTTED VIBRATION SPECTRA COUPLING GUARD TYPE RECORD FINAL ASSEMBLY RUNNING CLEARANCES (8.2.1.1f) PERFORMANCE CURVE & DATA STEEL BRASS NON-METALLIC OTHER NON SPARK COUPLING GUARD APPROVAL PRIOR TO SHIPMENT (8.3.9) (7.2.15)
MOTOR DRIVER (SEE MOTOR DATA SHEET) IEEE 841 API 541 API 546 OTHER ASD SUPPLIED BY PURCHASER MOTOR SUPPLIER MANUFACTURER TYPE FRAME ENCLOSURE HORIZONTAL VERTICAL (kW) (rpm) VOLTS PHASE HERTZ SERVICE FACTOR VARIABLE SPEED RANGE (rpm) MINIMUM STARTING VOLTAGE (7.1.2.2) INSULATION TEMP. RISE FULL LOAD AMPS LOCKED ROTOR AMPS STARTING METHOD LUBE BEARINGS (TYPEINUMBER): RADIAL I THRUST I
ITEM NO.
OF
REQ'N NO.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
MANIFOLD PIPING FOR PURCHASER CONNECTION DOMESTIC EXPORT EXPORT BOXING REQ'D VENT DRAIN STEAM / COOLING WATER HEATING JACKET REQ'D. OUTDOOR STORAGE MORE THAN 6 MONTHS (6.3.6) COOLING REQ'D PIPE TUBING; FITTINGS C.S. GALVANIZED S. STEEL VALVES: CARBON STEEL SURFACE PREPARATION AND PAINT S. STEEL FLANGES REQUIRED IN PLACE OF SOCKET WELD UNIONS MOUNT SEAL POT OFF BASEPLATE CONNECTION BOLTING CADMIUM PLATED BOLTS PROHIBITED PTFE COATING ASTM A153 GALVANIZED PAINTED SS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
MANIFOLD PIPING FOR PURCHASER CONNECTION VENT DRAIN STEAM / COOLING WATER HEATING JACKET REQ'D. (6.3.6) COOLING REQ'D PIPE TUBING; FITTINGS C.S. GALVANIZED S. STEEL VALVES: CARBON STEEL S. STEEL FLANGES REQUIRED IN PLACE OF SOCKET WELD UNIONS MOUNT SEAL POT OFF MANUFACTURER'S STANDARD BASEPLATE PUMP: (8.4.3.1) PRIMER FINISH COAT CONNECTION BOLTING CADMIUM PLATED BOLTS PROHIBITED PTFE COATING BASEPLATE: (8.4.3.1) PRIMER FINISH COAT ASTM A153 GALVANIZED PAINTED SS
HEATING AND COOLING HEATING MEDIUM: STEAM OTHER STEAM JACKET/COOLING WATER PRES: (barG) @ (C) COOLING PUMP BASE WATER REQUIREMENTS: BEARING HOUSING (m3/h) @ (barG) LUBE OIL COOLER (m3/h) @ (barG) SEAL OIL COOLER (m3/h) @ (barG) OTHER (m3/h) @ (barG) BY PUMP MANUFACTURER TOTAL COOLING WATER (m3/h) @ (barG) DRAIN-RIM DRAIN-PAN NON-GROUT CONSTRUCTION (7.4.2) INSTRUMENTATION ACCELEROMETER PROVISION FOR MTG ONLY FLAT SURFACE REQUIRED RADIAL BEARING TEMP. TEMP. GAUGES (WITH THERMOW PRESSURE GAUGE TYPE OTHER PURCHASER REQUIREMENTS THRUST BEAR ELLS) OTHER ING TEMP. NAMEPLATE UNITS RELIEF VALVES BY PUMP MFRG FLUSH FURNISHED BY: PUMP VENDOR PUMP VENDOR INSTALLATION LIST IN PROPOSAL U.S. CUSTOMARY INTERNAL SI EXTRNL. PIPING FOR SEAL WEIGHTS GEAR (kg) DRIVER TOTAL WEIGHT
OTHERS PIPING FOR COOLING/HEATING FURNISHED BY: OTHERS PROVIDE TECHNICAL DATA MANUAL (9.2.3.1)
REMARKS:
REMARKS:
OF
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
PURCHASE
NOTE:
BY MANUFACTURER GENERAL
BY MANUFACTURER OR PURCHASER
NO. MOTORS DRIVEN MOTOR ITEM NO'S DRIVER PROVIDED BY GEAR MOUNTED BY MOTOR DATA SHEET NO.
OTHER DRIVER TYPE PUMP ITEM NO'S DRIVER ITEM NO'S GEAR PROVIDED BY MOTOR MOUNTED BY DRIVER DATA SHEET NO.
PUMP ITEM NO'S GEAR ITEM NO'S MOTOR PROVIDED BY DRIVER MOUNTED BY GEAR DATA SHEET NO.
OPERATING CONDITIONS
PUMPED FLUID
14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61
MIN NORMAL RATED MAX (1) CAPACITY: (gpm) OTHER OPER CONDITIONS: (gpm) DISCHARGE PRESSURE: (psig) SUCTION PRESSURE : (psig) DIFFERENTIAL PRESSURE: (psi) NPSH AVAILABLE (ft) NPIP AVAILABLE (psia) NPSHAa / NPIP DATUM: C.L. SUCTION NOZZLE TOP OF FOUNDATION DUTY CYCLE CONTINUOUS INTERMITTENT (1) Maximum - mechanical design
TYPE OR NAME OF PUMPED FLUID MIN NORMAL RATED TEMPERATURE: (OF) VAPOR PRESS.: (psia) RELATIVE DENSITY (SG): VISCOSITY: (cP) SPECIFIC HEAT Cp (BTU/lb OF) CORROSIVE/EROSIVE AGENTS DESCRIPTION EROSIVE CORROSIVE CHLORIDE CONCENTRATION (ppm) H2S CONCENTRATION (ppm) FLUID HAZARDOUS FLAMMABLE OTHER GAS ENTRAINED SLUG FLOW % BY VOLUME or GVF SOLIDS PARTICLE SIZE DISTRIBUTION & MIN/MAX () SHAPE CONCENTRATION HARDNESS
PERFORMANCE RATED CAPACITY (gpm) NPSHa / NPIP REQUIRED (ft) (psia) RATED SPEED (rpm) RATED VOLUMETRIC EFFICIENCY (%) RATED PUMP EFFICIENCY (%) REQUIRED POWER @ MAXIMUM VISCOSITY (BHP) REQUIRED POWER @ PRESSURE LIMITING VAL (BHP) REQUIRED POWER @ RATED CONDITION (BHP) MAXIMUM ALLOWABLE SPEED (rpm)
SITE AND UTILITY DATA LOCATION INDOOR OUTDOOR HEATED UNHEATED UNDER ROOF ELECTRICAL AREA CLASS GROUP DIV ZONE GROUP TEMP CLASS WINTERIZATION REQD TROPICALIZATION REQD SITE DATA ELEVATION (OF) BAROMETER (psia) RANGE OF AMBIENT TEMPS:MIN/MAX / (OF) UNUSUAL CONDITIONS DUST FUMES SALT ATMOSPHERE OTHER UTILITY CONDITIONS ELECTRICITY DRIVERS HEATING CONTROL SHUTDOWN VOLTAGE HERTZ PHASE COOLING WATER INLET RETURN DESIGN MAX TEMP (OF) MAX PRESS. (psig) MIN SOURCE INSTRUMENT AIR MAX MIN PRESSURE (psig)
CONSTRUCTION CONNECTIONS SIZE SUCTION DISCHARGE GLAND FLUSH DRAINS * VENTS * JACKET ANSI RATING FACING POSITION
* PIPE VENTS & DRAINS TO EDGE OF BASEPLATE PUMP TYPE INTERNAL GEAR TWIN-SCREW VANE LOBE EXTERNAL GEAR 3-SCREW PROGRESSING CAVITY ROTARY GEAR TYPE
APPLICABLE SPECIFICATIONS: API-676 POSITIVE DISPLACEMENT PUMPS - ROTARY GOVERNING SPECIFICATION (IF DIFFERENT) NACE MR0103 (6.13.2.13) NACE MR0175 OTHER
REMARKS:
ITEM NO.
OF
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
CONSTRUCTION CASING MAX. ALLOWABLE CASING PRESS. (6.3.1): (psig) @ (OF) MAXIMUM ALLOWABLE SUCTION PRESSURE: (psig) @ (OF) HYDROSTATIC TEST PRESSURE - Suct I Disch: I (psig) ROTATING ELEMENTS ROTOR MOUNT BTWN. BEARINGS OVERHUNG TIMING GEARS YES NO TYPE BEARING TYPE: RADIAL THRUST BEARING NUMBER: RADIAL THRUST LUBRICATION TYPE: CONSTANT LEVEL OILERS PUMPED FLUID RING OIL OIL MIST EXTERNAL OIL FLOOD GREASE LUBRICANT Info (Visc, etc) MECHANICAL SEALS MANUFACTURER AND MODEL MANUFACTURER CODE API 682 AND DATA SHEETS API 682 SEAL FLUSH PLAN API 682 SEAL CODE
MIN DESIGN METAL TEMP (6.13.6.1) STATOR I LINER END PLATES ROTOR (S) VANES SHAFT SLEEVE (S) GLAND (S) BEARING HOUSING TIMING GEARS ELASTOMERS I GASKETS
(OF) CASING
13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57
LUBRICANT Info (Visc, etc) MECHANICAL SEALS MANUFACTURER AND MODEL MANUFACTURER CODE API 682 AND DATA SHEETS API 682 SEAL FLUSH PLAN API 682 SEAL CODE
SPECIAL MATERIAL TESTS (See design codes + weld + inspection sheet) LOW AMBIENT TEMP. MATERIALS TESTS (6.13.6.5) COMPLIANCE WITH INSPECTORS CHECK LIST CERTIFICATION OF MATERIALS (user to define affected components in remarks) SURFACE I SUBSURFACE EXAM'S (user to define affected components in remarks) RADIOGRAPHY ULTRASONIC MAGNETIC PARTICLE LIQUID PENETRANT COMPONENT PMI HARDNESS OF PARTS, WELDS & HEAT AFFECTED ZONES VENDOR SUBMIT TEST PROCEDURES (8.3.1.2) SUPPLIER TO KEEP REPAIR AND HT RECORDS (8.2.1.1) DRIVER TYPE NON-WIT WIT OBSERV SHOP INSPECTION (8.1) INDUCTION MOTOR STEAM TURBINE GEAR OTHER HYDROSTATIC (8.3.2) WITH WETTING AGENT PERFORMANCE (8.3.4) RETEST ON SEAL LEAKAGE NPSH I NPIP (8.3.7.1) DRIVE MECHANISM TRUE PEAK VELOCITY DATA COMPLETE UNIT TEST (8.3.7.2) SOUND LEVEL TEST (8.3.7.3) DIRECT-COUPLED ASD OTHER COUPLING MANUFACTURER CLEANLINESS PRIOR TO COUPLING TYPE FINAL ASSEMBLY (8.2.3.3) RATING (MAX TORQUE) MODEL SPACER LENGTH HIGH DISCHARGE PRESSURE @ PLV CHECK FOR CO-PLANAR AT MOUNTING PAD SURFACES (7.4.7) (IN) S.F. 1 HR MECHANICAL RUN TEST AFTER OIL TEMP STABLE (8.3.5.1) COUPLING BALANCED MANF STD AGMA 9000 CLASS 10 (7.2.3) COUPLING PER API 4 HR. MECH RUN AFTER 671 (7.2.4) OIL TEMP STABLE(8.3.5.2) AUXILIARY EQUIPMENT TEST (8.3.4.3) OTHER COUPLING HUB ATTACHMENT TEST WITH SUBSTITUTE SEAL (8.3.5.3) STRAIGHT KEYED TAPERED SUPPLIER SUBMIT TEST DATA WITHIN 24 HOURS INCLUDE PLOTTED VIBRATION SPECTRA COUPLING GUARD TYPE RECORD FINAL ASSEMBLY RUNNING CLEARANCES (8.2.1.1f) PERFORMANCE CURVE & DATA STEEL BRASS NON-METALLIC OTHER NON SPARK COUPLING GUARD APPROVAL PRIOR TO SHIPMENT (8.3.9) (7.2.15)
MOTOR DRIVER (SEE MOTOR DATA SHEET) IEEE 841 API 541 API 546 OTHER ASD SUPPLIED BY PURCHASER MOTOR SUPPLIER MANUFACTURER TYPE FRAME ENCLOSURE HORIZONTAL VERTICAL (HP) (rpm) VOLTS PHASE HERTZ SERVICE FACTOR VARIABLE SPEED RANGE (rpm) MINIMUM STARTING VOLTAGE (7.1.2.2) INSULATION TEMP. RISE FULL LOAD AMPS LOCKED ROTOR AMPS STARTING METHOD LUBE BEARINGS (TYPEINUMBER): RADIAL I THRUST I
ITEM NO.
OF
REQ'N NO.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43
PIPING & APPURTENANCES MANIFOLD PIPING FOR PURCHASER CONNECTION VENT DRAIN STEAM / COOLING WATER HEATING JACKET REQ'D. (6.3.6) COOLING REQ'D PIPE TUBING; FITTINGS C.S. GALVANIZED S. STEEL VALVES: CARBON STEEL S. STEEL FLANGES REQUIRED IN PLACE OF SOCKET WELD UNIONS MOUNT SEAL POT OFF BASEPLATE CONNECTION BOLTING CADMIUM PLATED BOLTS PROHIBITED PTFE COATING ASTM A153 GALVANIZED PAINTED SS
PREPARATION FOR SHIPMENT DOMESTIC EXPORT EXPORT BOXING REQ'D OUTDOOR STORAGE MORE THAN 6 MONTHS SURFACE PREPARATION AND PAINT MANUFACTURER'S STANDARD PUMP: (8.4.3.1) PRIMER FINISH COAT BASEPLATE: (8.4.3.1) PRIMER FINISH COAT OTHER (SEE BELOW) SPECIFICATION NO.
HEATING AND COOLING HEATING MEDIUM: STEAM OTHER STEAM JACKET/COOLING WATER PRES: (psig) WATER REQUIREMENTS: BEARING HOUSING (gpm) @ COOLER (gpm) @ (gpm) @ (psig) OTHER (psig) TOTAL COOLING WATER (gpm) @ WEIGHTS @ (OF) COOLING PUMP BASE GEAR (Ib) DRIVER TOTAL WEIGHT
INSTRUMENTATION ACCELEROMETER PROVISION FOR MTG ONLY FLAT SURFACE REQUIRED RADIAL BEARING TEMP. TEMP. GAUGES (WITH THERMOW PRESSURE GAUGE TYPE OTHER PURCHASER REQUIREMENTS
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
ACCELEROMETER PROVISION FOR MTG ONLY FLAT SURFACE REQUIRED RADIAL BEARING TEMP. TEMP. GAUGES (WITH THERMOW PRESSURE GAUGE TYPE
ING TEMP.
NAMEPLATE UNITS RELIEF VALVES BY PUMP MFRG FLUSH FURNISHED BY: PUMP VENDOR PUMP VENDOR INSTALLATION LIST IN PROPOSAL
OTHERS PIPING FOR COOLING/HEATING FURNISHED BY: OTHERS PROVIDE TECHNICAL DATA MANUAL (9.2.3.I)
REMARKS:
REMARKS:
REVISION DATE BY
MULTIPHASE
REV/APPR
MULTIPHASE PUMP DATA SHEET (API 676 3rd Ed.) SI UNITS (bar)
ITEM NO.
OF
REQ'N NO.
1 2 3 3 4 5 6 7 8 9
LOCATION: INDOOR HEATED UNDER ROOF OUTDOOR UNHEATED PARTIAL SIDES GRADE MEZZANINE ELECTRICAL AREA CLASS NON-HAZARDOUS CL GR TEMP CLASS ZONE CLASS GROUP WINTERIZATION REQ'D. TROPICALIZATION REQ'D. SITE DATA: ELEVATION
DIV.
CONNECTIONS: ANSI POSI- SIZE CASING (4.3) INLET DISCHARGE SKID INLET SKID OUTLET OTHER CONNECTIONS: SERVICE: NO
RATING
FACING
TION
SIZE
(m) BAROMETER
(barA)
LUBE OIL OUTLET SEAL OIL INLET SEAL OIL OUTLET CASING DRAINS VENTS COOLING WATER CASE PRESSURE TEMPERATURE PURGE FOR:
RANGE OF AMBIENT TEMPS.: DRY BULB WET BULB SITE RATED (C) 10 NORMAL (C) MAXIMUM (C) MINIMUM (C) 11 UNUSUAL CONDITIONS: 12 DUST FUMES SALT ATMOSPHERE OTHER 13 14 15 16 17 18 19 20 21 22 23 24 25 26 UTILITY CONDITIONS: 27 STEAM DRIVERS HEATING INDUCTION MOTOR 28 INLET MIN. (barG) (C) (barG) (C) NORM (barG) 29 (C) (barG) (C) MAX. (barG) (C) (barG) (C) 30 EXHAUST MIN. (barG) (C) (barG) (C) NORM (barG) 31 (C) (barG) (C) MAX. (barG) (C) (barG) (C) 32 ELECTRICITY: SHUT- DRIVERS 33 HEATING CONTROL DOWN 34 VOLTAGE HERTZ PHASE 35 COOLING WATER 36 TEMP. INLET (C) MAX. RETURN (C) PRESS. NORM 37 (barG) DESIGN (barG) 38 MIN. RETURN (barG) MAX. ALLOW D P (barA) WATER SOURCE 39 INSTRUMENT AIR: 40 MAX PRESS (barG) MIN. (barG) 41 TOTAL UTILITY CONSUMPTION:
DRIVE MECHANISM
22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55
UTILITY CONDITIONS: STEAM DRIVERS HEATING INLET MIN. (barG) (C) (barG) (C) NORM (barG) (C) (barG) (C) MAX. (barG) (C) (barG) (C) EXHAUST MIN. (barG) (C) (barG) (C) NORM (barG) (C) (barG) (C) MAX. (barG) (C) (barG) (C) ELECTRICITY: SHUT- DRIVERS HEATING CONTROL DOWN VOLTAGE HERTZ PHASE COOLING WATER TEMP. INLET (C) MAX. RETURN (C) PRESS. NORM (barG) DESIGN (barG) MIN. RETURN (barG) MAX. ALLOW D P (barA) WATER SOURCE INSTRUMENT AIR: MAX PRESS (barG) MIN. (barG) TOTAL UTILITY CONSUMPTION: COOLING WATER (L/min) STEAM, NORMAL (kg/h) STEAM, MAX (kg/h) INSTRUMENT AIR (m3/h) POWER (DRIVER) (kW) POWER (AUXILIARIES): (kW)
DIRECT-COUPLED ASD OTHER COUPLING MANUFACTURER COUPLING TYPE RATING (MAX TORQUE) MODEL SPACER LENGTH (IN) S.F. COUPLING BALANCED MANF STD ISO 1940-1 G6.3 (7.2.3) COUPLING PER API 671 (7.2.4) COUPLING HUB ATTACHMENT TAPERED STRAIGHT KEYED HYRDRAULIC FIT COUPLING GUARD TYPE STEEL BRASS NON-METALLIC OTHER NON SPARK COUPLING GUARD (7.2.15c)
MOTOR DRIVER (7.1) (SEE MOTOR DATA SHEET) IEEE 841 API 541 API 546 OTHER ASD SUPPLIED BY PURCHASER MOTOR SUPPLIER MANUFACTURER TYPE FRAME ENCLOSURE HORIZONTAL VERTICAL (kW) (rpm) VOLTS PHASE HERTZ SERVICE FACTOR VARIABLE SPEED RANGE (rpm) MINIMUM STARTING VOLTAGE (7.1.2.2) INSULATION TEMP. RISE FULL LOAD AMPS LOCKED ROTOR AMPS STARTING METHOD LUBE DRIVER BEARINGS (TYPE/NUMBER): RADIAL / THRUST /
BASEPLATE (7.4) COMMON (UNDER PUMP & DRIVER) OTHER DECKED WITH NON-SKID DECK PLATE (7.4.12) OPEN CONSTR. DRIP RIM WITH OPEN DRAIN SUBPLATE HORIZONTAL ADJUSTING SCREWS FOR EQUIPMENT (7.4.4) EPOXY GROUT/EPOXY PRIMER
REMARKS
REVISION DATE BY
MULTIPHASE
9 COOLING I HEATING JACKET YES NO (6.3.6) 10 LINER 11 LINER MATERIAL (6.13) 12 HARD COATING MATERIAL 13 BEARING HOUSING MATERIAL 14 BEARING HOUSING COOLING 15 ROTORS: (6.8.1) 16 DIAMETER (mm)
REVIAPPR
17 EROSION HARD COATING 18 TYPE FABRICATION 19 MATERIAL (6.13) 20 BRINELL HARDNESS. MAX. 21 ROTOR LENGTH TO DIAMETER 22 ROTOR CLEARANCE 23 MAX. DEFLECTION (mm) (mm) RATIO (LID) MIN.
27 DIA @ ROTORS
(mm)
(mm)
40 AF BEARING OUTER RACE 41 TC TYPE 42 VIBRATION DETECTORS: 43 IN ACCORDANCE WITH: API 67 44 OTHER (SPECIFY) 45 TYPE 46 MFR. 47 NO. AT EACH BEARING 48 MONITOR SUPPLIED BY 49 LOCATION 50 MFR. 0
MODEL
TOTAL NO.
ENCLOSURE MODEL ALARM. SET @ MILS SET @ TIME DLY. MILS SEC REVISION DATE BY REV/APPR JOB NO. PAGE ITEM NO. o 1 2 3 4
MULTIPHASE PUMP DATA SHEET (API 676 3rd Ed.) SI UNITS (bar)
OF
REQ'N NO.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49
VENDOR MUST FURNISH ALL PERTINENT DATA FOR THIS SPECIFICATION SHEET BEFORE RETURNING. ITEM NO. SERVICE
LOCAL CONTROL PANEL: FURNISHED BY: SUPPLIER PURCHASER OTHERS FREE STANDING WEATHERPROOF TOTALLY ENCLOSED ANNUNCIATOR: FURNISHED BY: VENDOR PURCHASER CUSTOMER CONNECTIONS BROUGHT OUT TO TERMINAL BOXES BY VENDOR
INSTRUMENT SUPPLIERS: PRESSURE GAUGES: SIZE & TYPE: LEVEL GAUGES: SIZE & TYPE: PRESSURE TRANSMITTERS: SIZE & TYPE: TEMPERATURE TRANSMITTERS: SIZE & TYPE: CONTROL VALVES: SIZE & TYPE: SIGHT FLOW INDICATORS: SIZE & TYPE: VIBRATION EQUIPMENT: SIZE & TYPE: ANNUNCIATOR: OTHER
SIZE & TYPE: TEMPERATURE GAUGES: SIZE & TYPE: DIFF. PRESSURE GAUGES: SIZE & TYPE: DIFF. PRESSURE TRANSMITTERS: SIZE & TYPE: LEVEL SWITCHES: SIZE & TYPE: PRESSURE LIMITING VALVES: (7.5) SIZE & TYPE: FLOW INDICATOR: SIZE & TYPE: SOLENOID VALVES MODEL & NO. POINTS SIZE & TYPE:
PRESSURE GAUGE REQUIREMENTS LOCALLY LOCAL FUNCTION PANEL PUMP SUCTION PUMP DISCHARGE LUBE OIL PUMP DISCHARGE LUBE OIL FILTER LUBE OIL SUPPLY
NOTE:
SUPPLIED BY PURCHASER LOCALLY LOCAL FUNCTION PANEL SEAL OIL PUMP DISCHARGE SEAL OIL FILTER P SEAL OIL SUPPLY SEAL OIL DIFFERENTIAL OTHER MOUNTED
TEMPERATURE GAUGE REQUIREMENTS: LOCALLY LOCAL FUNCTION MOUNTED PANEL LUBE DRAIN @ EA. BRG. PUMP RADIAL BEARING PUMP THRUST BEARING SEAL OIL OUTLET OTHER
LOCALLY LOCAL FUNCTION MOUNTED OUTLET LUBE OIL RESERVOIR SEAL OIL RESERVOIR PUMP SUCTION PUMP DISCHARGE
SWITCH CLOSURES: ALARM CONTACTS SHALL: OPEN CLOSE TO SOUND ALARM AND BE NORMALLY OPEN CLOSE TO TRIP AND BE NORMALLY ENERGIZED DE-ENERGIZED NOTE: NORMAL CONDITION IS WHEN MPP IS IN OPERATION.
ENERGIZED
MULTIPHASE PUMP DATA SHEET (API 676 3rd Ed.) SI UNITS (bar)
REVISION DATE
MULTIPHASE PUMP DATA SHEET (API 676 3rd Ed.) SI UNITS (bar)
BY REV/APPR JOB NO. PAGE VENDOR MUST FURNISH ALL PERTINENT DATA FOR THIS SPECIFICATION SHEET BEFORE RETURNING. ITEM NO. SERVICE ITEM NO.
OF
REQ'N NO.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53
ALARM & SHUTDOWN: FUNCTION ALARM TRIP LOW LUBE OIL PRESSURE HI LUBE OIL FILTER P HI SEAL OIL FILTER P LOW LUBE OIL RESERVOIR LEV. LOW SEAL OIL RESERVOIR LEV. HI SEAL OIL LEVEL LOW SEAL OIL LEVEL HI SEAL OIL PRESSURE LOW SEAL OIL PRESSURE AUX. SEAL OIL PUMP START AUX. LUBE OIL PUMP START
PREFUNCTION ALARM TRIP PUMP VIBRATION HI SEAL OIL OUTLET TEMP. (COOLER) PUMP HI DISCH. TEMP. HI LUBE OIL OUTLET TEMP. (COOLER) DRIVER VIBRATION DRIVER SHUTDOWN HI PUMP BRG. TEMP. HI DRIVER BRG. TEMP. PUMP D P OTHER OTHER
MISCELLANEOUS INSTRUMENTATION: DRIVER START/STOP LOCAL PANEL SEPARATE PANEL MAIN BOARD SIGHT FLOW INDICATORS, EACH BEARING HOUSING SIGHT FLOW INDICATORS, EACH SEAL OIL RETURN LINE VIBRATION DETECTORS VIBRATION AND BEARING TEMPERATURE MONITORS VIBRATION READOUT LOCATED ON: LOCAL PANEL SEPARATE PANEL MAIN BOARD LEVEL GAUGES, LUBE AND/OR SEAL OIL RESERVOIR OTHER MISCELLANEOUS: INSTRUMENT TAGGING REQUIRED. ALARM AND SHUTDOWN TRANSMITTERS SHALL BE SEPARATE. PURCHASERS ELECTRICAL AND INSTRUMENT CONNECTIONS WITHIN THE CONFINES OF THE BASEPLATE AND CONSOLE SHALL BE: BROUGHT OUT TO TERMINAL BOXES. MADE DIRECTLY BY THE PURCHASER. COMMENTS REGARDING INSTRUMENTATION:
PUMP SHOP INSPECTION AND TESTS: SHOP INSPECTION (8.1) HYDROSTATIC (8.3.2) MECHANICAL RUN (8.3.5.1) MECHANICAL RUN SPARE ROTORS CASING LEAK TEST PERFORMANCE TEST (GAS) (LIQUID) COMPLETE UNIT TEST (8.3.7.2) USE SHOP LUBE & SEAL SYSTEM USE CONTRACT LUBE & SEAL SYSTEM USE CONTRACT VIBRATION PROBES, E USE JOB BEARING VIBRATION AND TEM TRANSDUCERS & MONITORS PRESSURE PUMP TO FULL OPER. PRES DISASSEMBLEREASSEMBLE PUMP AFTER TEST INSPECT BEARINGS AFTER TEST SOUNDLEVEL TEST (8.3.7.3) AUX. EQUIPMENT (8.3.4.3) FULL-LOAD STRING TEST GAS SLUG TEST REQ'D TC. S. WITNESS OBSERVE PERATURE MISCELLANEOUS: RECOMMEND STRAIGHT RUN OF PIPE DIA. BEFORE SUCTION VENDOR'S REVIEW & COMMENTS ON PURCHASER'S PIPING & FOUNDATION (7.8.2.d NOTE 4) VENDOR REPRESENTATIVE OBSERVATION AT THE SITE SPARE PARTS TO BE SUPPLIED ROTOR ASSEMBLY BEARINGS SEALS 2 YEARS SUPPLY GASKETS, O-RINGS START-UP/COMMISSIONING OTHER
WEIGHTS: (kg) PUMP DRIVER ROTORS: PUMP DRI LUBE OIL CONSOLE CONSOLE SEAL OIL CONSOLE MAX. FOR MAINTENANCE (IDENTIFY) TOTAL SHIPPING WEIGHT
BASEPLATE VER
REVISION DATE BY
MULTIPHASE
REV/APPR
MULTIPHASE PUMP DATA SHEET (API 676 3rd Ed.) U.S. CUSTOMARY
MULTIPHASE PUMP DATA SHEET (API 676 3rd Ed.) U.S. CUSTOMARY
JOB NO. PAGE 1 2 3 3 4 5 6 7 8 9 LOCATION: INDOOR HEATED UNDER ROOF OUTDOOR UNHEATED PARTIAL SIDES GRADE MEZZANINE ELECTRICAL AREA CLASS NON-HAZARDOUS CL GR TEMP CLASS ZONE CLASS GROUP WINTERIZATION REQ'D. TROPICALIZATION REQ'D. SITE DATA: ELEVATION
ITEM NO.
OF
REQ'N NO.
DIV.
CONNECTIONS: ANSI POSI- SIZE CASING (4.3) INLET DISCHARGE SKID INLET SKID OUTLET OTHER CONNECTIONS: SERVICE: NO
RATING
FACING
TION
SIZE
(ft) BAROMETER
(psia)
LUBE OIL OUTLET SEAL OIL INLET SEAL OIL OUTLET CASING DRAINS VENTS COOLING WATER CASE PRESSURE TEMPERATURE PURGE FOR:
RANGE OF AMBIENT TEMPS.: DRY BULB WET BULB SITE RATED (OF) 10 NORMAL (OF) MAXIMUM (OF) MINIMUM (OF) 11 UNUSUAL CONDITIONS: 12 DUST FUMES SALT ATMOSPHERE OTHER 13 14 15 16 17 18 19 20 21 22 23 24 25 26 UTILITY CONDITIONS: 27 STEAM DRIVERS HEATING 28 INLET MIN. (psig) (OF) (psig) (OF) NORM 29 (psig) (OF) (psig) (OF) MAX. (psig) (OF) 30 (psig) (OF) 31 EXHAUST MIN. (psig) (OF) (psig) (OF) NORM 32 (psig) (OF) (psig) (OF) MAX. (psig) (OF) 33 (psig) (OF) 34 ELECTRICITY: SHUT- DRIVERS 35 HEATING CONTROL DOWN 36 VOLTAGE HERTZ PHASE 37 COOLING WATER 38 TEMP. INLET (OF) MAX. RETURN (OF) PRESS. 39 NORM (psig) DESIGN (psig) 40 MIN. RETURN (psig) MAX. ALLOW D P (psia) WATER SOURCE 41 INSTRUMENT AIR: 42 MAX PRESS (psig) MIN. (psig) 43 TOTAL UTILITY CONSUMPTION: 44 COOLING WATER (gph) STEAM, NORMAL 45 (Ib/hr) STEAM, MAX (Ib/hr) INSTRUMENT 46 AIR (scfm) POWER (DRIVER) 47 (HP) POWER (AUXILIARIES): (HP) 48 49 50 51 52 53 54 55
DRIVE MECHANISM DIRECT-COUPLED ASD OTHER COUPLING MANUFACTURER COUPLING TYPE RATING (MAX TORQUE) MODEL SPACER LENGTH (IN) S.F. COUPLING BALANCED MANF STD ISO 1940-1 G6.3 (7.2.3) COUPLING PER API 671 (7.2.4) COUPLING HUB ATTACHMENT TAPERED STRAIGHT KEYED HYRDRAULIC FIT COUPLING GUARD TYPE STEEL BRASS NON-METALLIC OTHER NON SPARK COUPLING GUARD (7.2.15c)
MOTOR DRIVER (7.1) (SEE MOTOR DATA SHEET) IEEE 841 API 541 API 546 OTHER ASD SUPPLIED BY PURCHASER MOTOR SUPPLIER MANUFACTURER TYPE FRAME ENCLOSURE HORIZONTAL VERTICAL (HP) (rpm) VOLTS PHASE HERTZ SERVICE FACTOR VARIABLE SPEED RANGE (rpm) MINIMUM STARTING VOLTAGE (7.1.2.2) INSULATION TEMP. RISE FULL LOAD AMPS LOCKED ROTOR AMPS STARTING METHOD LUBE DRIVER BEARINGS (TYPE/NUMBER): RADIAL / THRUST /
BASEPLATE (7.4) COMMON (UNDER PUMP & DRIVER) OTHER DECKED WITH NON-SKID DECK PLATE (7.4.12) OPEN CONSTR. DRIP RIM WITH OPEN DRAIN SUBPLATE HORIZONTAL ADJUSTING SCREWS FOR EQUIPMENT (7.4.4) EPOXY GROUT/EPOXY PRIMER
REMARKS
REVISION DATE BY
MULTIPHASE
9 COOLING I HEATING JACKET YES NO (6.3.6) 10 LINER 11 LINER MATERIAL (6.13) 12 HARD COATING MATERIAL 13 BEARING HOUSING MATERIAL 14 BEARING HOUSING COOLING 15 ROTORS: (6.8.1) 16 DIAMETER (in)
REVIAPPR
17 EROSION HARD COATING 18 TYPE FABRICATION 19 MATERIAL (6.13) 20 BRINELL HARDNESS. MAX. 21 ROTOR LENGTH TO DIAMETER 22 ROTOR CLEARANCE 23 MAX. DEFLECTION (in) OTHER RTD TYPE (in) RATIO (LID) MIN.
40 AF BEARING OUTER RACE 41 TC TYPE 42 VIBRATION DETECTORS: 43 IN ACCORDANCE WITH: API 67 44 OTHER (SPECIFY) 45 TYPE 46 MFR. 47 NO. AT EACH BEARING 48 MONITOR SUPPLIED BY 49 LOCATION 50 MFR. 0
MODEL
TOTAL NO.
ENCLOSURE MODEL ALARM. SET @ MILS SET @ TIME DLY. MILS SEC REVISION DATE BY REV/APPR JOB NO. PAGE ITEM NO. o 1 2 3 4
MULTIPHASE PUMP DATA SHEET (API 676 3rd Ed.) U.S. CUSTOMARY
OF
REQ'N NO.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49
VENDOR MUST FURNISH ALL PERTINENT DATA FOR THIS SPECIFICATION SHEET BEFORE RETURNING. ITEM NO. SERVICE
LOCAL CONTROL PANEL: FURNISHED BY: SUPPLIER PURCHASER OTHERS FREE STANDING WEATHERPROOF TOTALLY ENCLOSED ANNUNCIATOR: FURNISHED BY: VENDOR PURCHASER CUSTOMER CONNECTIONS BROUGHT OUT TO TERMINAL BOXES BY VENDOR
INSTRUMENT SUPPLIERS: PRESSURE GAUGES: SIZE & TYPE: LEVEL GAUGES: SIZE & TYPE: PRESSURE TRANSMITTERS: SIZE & TYPE: TEMPERATURE TRANSMITTERS: SIZE & TYPE: CONTROL VALVES: SIZE & TYPE: SIGHT FLOW INDICATORS: SIZE & TYPE: VIBRATION EQUIPMENT: SIZE & TYPE: ANNUNCIATOR: OTHER
SIZE & TYPE: TEMPERATURE GAUGES: SIZE & TYPE: DIFF. PRESSURE GAUGES: SIZE & TYPE: DIFF. PRESSURE TRANSMITTERS: SIZE & TYPE: LEVEL SWITCHES: SIZE & TYPE: PRESSURE LIMITING VALVES: (7.5) SIZE & TYPE: FLOW INDICATOR: SIZE & TYPE: SOLENOID VALVES MODEL & NO. POINTS SIZE & TYPE:
NOTE:
SUPPLIED BY VENDOR
SUPPLIED BY PURCHASER
33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49
LOCALLY LOCAL FUNCTION PANEL PUMP SUCTION PUMP DISCHARGE LUBE OIL PUMP DISCHARGE LUBE OIL FILTER LUBE OIL SUPPLY
MOUNTED
LOCALLY LOCAL FUNCTION PANEL SEAL OIL PUMP DISCHARGE SEAL OIL FILTER P SEAL OIL SUPPLY SEAL OIL DIFFERENTIAL OTHER
MOUNTED
TEMPERATURE GAUGE REQUIREMENTS: LOCALLY LOCAL FUNCTION MOUNTED PANEL LUBE DRAIN @ EA. BRG. PUMP RADIAL BEARING PUMP THRUST BEARING SEAL OIL OUTLET OTHER
LOCALLY LOCAL FUNCTION MOUNTED OUTLET LUBE OIL RESERVOIR SEAL OIL RESERVOIR PUMP SUCTION PUMP DISCHARGE
SWITCH CLOSURES: ALARM CONTACTS SHALL: OPEN CLOSE TO SOUND ALARM AND BE NORMALLY OPEN CLOSE TO TRIP AND BE NORMALLY ENERGIZED DE-ENERGIZED NOTE: NORMAL CONDITION IS WHEN MPP IS IN OPERATION.
ENERGIZED
MULTIPHASE PUMP DATA SHEET (API 676 3rd Ed.) U.S. CUSTOMARY
ITEM NO.
OF
REQ'N NO.
VENDOR MUST FURNISH ALL PERTINENT DATA FOR THIS SPECIFICATION SHEET BEFORE RETURNING. ITEM NO. SERVICE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53
ALARM & SHUTDOWN: FUNCTION ALARM TRIP LOW LUBE OIL PRESSURE HI LUBE OIL FILTER P HI SEAL OIL FILTER P LOW LUBE OIL RESERVOIR LEV. LOW SEAL OIL RESERVOIR LEV. HI SEAL OIL LEVEL LOW SEAL OIL LEVEL HI SEAL OIL PRESSURE LOW SEAL OIL PRESSURE AUX. SEAL OIL PUMP START AUX. LUBE OIL PUMP START
PREFUNCTION ALARM TRIP PUMP VIBRATION HI SEAL OIL OUTLET TEMP. (COOLER) PUMP HI DISCH. TEMP. HI LUBE OIL OUTLET TEMP. (COOLER) DRIVER VIBRATION DRIVER SHUTDOWN HI PUMP BRG. TEMP. HI DRIVER BRG. TEMP. PUMP D P OTHER OTHER
MISCELLANEOUS INSTRUMENTATION: DRIVER START/STOP LOCAL PANEL SEPARATE PANEL MAIN BOARD SIGHT FLOW INDICATORS, EACH BEARING HOUSING SIGHT FLOW INDICATORS, EACH SEAL OIL RETURN LINE VIBRATION DETECTORS VIBRATION AND BEARING TEMPERATURE MONITORS VIBRATION READOUT LOCATED ON: LOCAL PANEL SEPARATE PANEL MAIN BOARD LEVEL GAUGES, LUBE AND/OR SEAL OIL RESERVOIR OTHER MISCELLANEOUS: INSTRUMENT TAGGING REQUIRED. ALARM AND SHUTDOWN TRANSMITTERS SHALL BE SEPARATE. PURCHASERS ELECTRICAL AND INSTRUMENT CONNECTIONS WITHIN THE CONFINES OF THE BASEPLATE AND CONSOLE SHALL BE: BROUGHT OUT TO TERMINAL BOXES. MADE DIRECTLY BY THE PURCHASER. COMMENTS REGARDING INSTRUMENTATION:
PUMP SHOP INSPECTION AND TESTS: SHOP INSPECTION (8.1) HYDROSTATIC (8.3.2) MECHANICAL RUN (8.3.5.1) MECHANICAL RUN SPARE ROTORS CASING LEAK TEST PERFORMANCE TEST (GAS) (LIQUID) COMPLETE UNIT TEST (8.3.7.2) USE SHOP LUBE & SEAL SYSTEM USE CONTRACT LUBE & SEAL SYSTEM USE CONTRACT VIBRATION PROBES, E USE JOB BEARING VIBRATION AND TEM TRANSDUCERS & MONITORS PRESSURE PUMP TO FULL OPER. PRES DISASSEMBLEREASSEMBLE PUMP AFTER TEST INSPECT BEARINGS AFTER TEST SOUNDLEVEL TEST (8.3.7.3) AUX. EQUIPMENT (8.3.4.3) FULL-LOAD STRING TEST GAS SLUG TEST REQ'D TC. S. WITNESS OBSERVE PERATURE MISCELLANEOUS: RECOMMEND STRAIGHT RUN OF PIPE DIA. BEFORE SUCTION VENDOR'S REVIEW & COMMENTS ON PURCHASER'S PIPING & FOUNDATION (7.8.2.d NOTE 4) VENDOR REPRESENTATIVE OBSERVATION AT THE SITE SPARE PARTS TO BE SUPPLIED ROTOR ASSEMBLY BEARINGS SEALS 2 YEARS SUPPLY GASKETS, O-RINGS START-UP/COMMISSIONING OTHER
WEIGHTS: (Ib) PUMP DRIVER ROTORS: PUMP DRI LUBE OIL CONSOLE CONSOLE SEAL OIL CONSOLE MAX. FOR MAINTENANCE (IDENTIFY) TOTAL SHIPPING WEIGHT
BASEPLATE VER
53
AFTER TEST INSPECT BEARINGS AFTER TEST SOUNDLEVEL TEST (8.3.7.3) AUX. EQUIPMENT (8.3.4.3) FULL-LOAD STRING TEST GAS SLUG TEST
PUMP DRIVER ROTORS: PUMP DRI LUBE OIL CONSOLE CONSOLE SEAL OIL CONSOLE MAX. FOR MAINTENANCE (IDENTIFY) TOTAL SHIPPING WEIGHT
PROPOSALS
PURCHASE
TYPE
BY PURCHASER
BY MANUFACTURER
BY MANUFACTURER OR PURCHASER
WELDING AND REPAIRS (6.13.5 & 6.13.1) THESE REFERENCES MUST BE LISTED BY THE PURCHASER. (DEFAULT TO TABLE 5 IF NO PURCHASER PREFERENCE IS STATED) ALTERNATE WELDING CODES AND STANDARDS (6.13.5.1) Welding Requirement (Applicable Code or Standard) WelderIoperator qualification Welding procedure qualification Non-pressure retaining structural welding such as baseplates or supports Magnetic Particle or Liquid Penetrant examination of plate edges Postweld heat treatment Postweld heat treatment of casing fabrication welds WELDING APPROVALS: Submit Weld Procedures for approval Submit Pressure Boundary Weld Maps for approval on major weld repairs at pump mfr. MATERIAL AND OTHER INSPECTIONS (8.2.2.1.1)(8.2.3.1) THESE REFERENCES MUST BE LISTED BY THE PURCHASER Type of inspection Para. (DEFAULT TO TABLE 6 IF NO PURCHASER METHOD PREFERENCE IS STATED) List Methods (if not API 676 defaults) Press Bdry. Fabs Piping Press. Bdry. Cstgs. Witness ALTERNATIVE MATERIAL INSPECTIONS AND ACCEPTANCE CRITERIA (SEE TABLE 6) Purchaser defined Default per Table 5
MSS-SP55 Visual casting Inspection Magnetic particle inspection at foundry Liquid penetrant inspection at foundry RT critical areas casing casting at foundry Magnetic particle insp. - finished machined Liquid penetrant insp. - finished machined RT critical areas casing - near fin. mach'd. MT or PT of Fabricated plate edges MT or PT case attachment welds MT or PT rotor at foundry RT butt welds in aux. piping MT or PT rotor - finished machined PMI all alloy pressure bndry components PMI alloy piping PMI alloy rotors Barstock with UT certificate for shaft Charpy Impact Test pressure bndry parts Casing caliper thickness check Rotor balance to ISO 1940 G2.5 Hardness of parts, welds & HAZ Record Final assembly Clearances Material Test Reports 6.13.2.10: HAZ is "heat affedted zone" APPLICABLE TO: FOR 0 SITE 0 PUMP SIZE 0 0 NO. REO 0 MANUFACTURER PAGE No. 1 LINE No. Casing
6.13.3.2 8.2.2.1.1 8.2.2.1.1 8.2.2.1.1 8.2.2.1.1 8.2.2.1.1 8.2.2.1.1 6.13.5.3d 8.2.2.1.1 8.2.2.1.1 ASME B31.3 or 31.4 or 31.8 8.2.2.1.1 8.2.4 8.2.4 8.2.4 8.2.2.1.1 6.13.6.5 6.8.1.9 8.2.1.1f Rotor I Vanes Stators Shaft Bolting Aux Piping
PROPOSALS
PURCHASE
0 0 0
0 NO. STAGES 0 SERIAL NO.