611 621 631 641 651 661 1.0 HP 1.5 HP 2.0 HP 3.0 HP 5.0 HP 7.5 HP (For Pump Prex Identication see News & Views 0052) SEWAGE-WASTE COMPARE THESE FEATURES Non-Clogging semi-open ductile iron impeller. Class 30 cast iron construction. Ductile iron semi-open impeller. All units are double seal for extra motor protection. Corrosion resistant powder coated epoxy nish. Stainless steel screws, washers, tag and seal assembly. 25 foot UL Listed power cord. Extra cord lengths available in 35 and 50 feet. Single phase - 230V capacitor start, capacitor run. Three Phase - 200-230-460-575 Volt. Motor - 60 Hz, 1750 RPM, oil-lled, hermetically sealed with heavy duty nned motor housing for added heat dissipation. Continuous duty operation in submerged conditions. Maximum temperature for sewage or dewatering 104F (40C) with 1.2 service factor (1.0 service factor on Model 661). 416 stainless steel motor shaft. Tandem shaft seals - stainless steel tted, carbon/ceramic seal faces. Oversized upper & lower ball bearings running in an oil bath. Buna-n square rings and seals used throughout. All models pass 2" spherical solids. Specify 3" NPT vertical, 3" horizontal anged or 4" horizontal anged discharge. 100% computerized tested. Major width 17 9 /16". Height 29 ". Rail systems available for all models. Control panels with overload protection available. SECTION: 2.30.070 FM1591 0207 Supersedes 0206 SUBMERSIBLE SEWAGE OR DEWATERING NON-CLOG PUMP MODELS AVAILABLE Nonautomatic (For variable level control systems). Double seal only. 3" Vertical, 3" Horizontal or 4" Horizontal anged discharge. 230V/1 Phase or 200/230/460/575V/3 Phase. Manufacturers of . . . Product information presented here reects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649 Cane Run Road Louisville, KY 40211-1961 (502) 778-2731 1 (800) 928-PUMP FAX (502) 774-3624 visit our web site: www.zoeller.com 600 SERIES 3" & 4" Horizontal Discharge 3" Vertical Discharge R 2 Copyright 2007 Zoeller Co. All rights reserved. Standard all models - 25 ft. cord - 1.0 HP Standard all models - 25 ft. cord - 1.5 HP 611 Models Volts Phase Mode Amps *E611 230 1 Nonauto 6.9 J611 200 3 Nonauto 4.3 F611 230 3 Nonauto 3.7 G611 460 3 Nonauto 1.9 BA611 575 3 Nonauto 1.6 621 Models Volts Phase Mode Amps *E621 230 1 Nonauto 8.9 J621 200 3 Nonauto 5.9 F621 230 3 Nonauto 5.1 G621 460 3 Nonauto 2.6 BA621 575 3 Nonauto 2.0 631 Models Volts Phase Mode Amps *E631 230 1 Nonauto 12.0 J631 200 3 Nonauto 7.8 F631 230 3 Nonauto 6.8 G631 460 3 Nonauto 3.4 BA631 575 3 Nonauto 2.7 Standard all models - 25 ft. cord - 2.0 HP Standard all models - 25 ft. cord - 3.0 HP 641 Models Volts Phase Mode Amps *E641 230 1 Nonauto 17.0 J641 200 3 Nonauto 11.0 F641 230 3 Nonauto 9.6 G641 460 3 Nonauto 4.8 BA641 575 3 Nonauto 3.9 Standard all models - 25 ft. cord - 5.0 HP 651 Models Volts Phase Mode Amps *E651 230 1 Nonauto 28.0 J651 200 3 Nonauto 17.5 F651 230 3 Nonauto 15.2 G651 460 3 Nonauto 7.6 BA651 575 3 Nonauto 6.1 Standard all models - 25 ft. cord - 7.5 HP 661 Models Volts Phase Mode Amps J661 200 3 Nonauto 25.3 F661 230 3 Nonauto 22.0 G661 460 3 Nonauto 11.0 BA661 575 3 Nonauto 9.0 For information on additional Zoeller products refer to catalog on Variable Control Switches, FM0526; Piggyback Variable Level Float Switches, FM0477; Electrical Alternator, FM0486; Mechanical Alternator, FM0495; Sump/Sewage Basins, FM0487; Alarm System, FM0732; Simplex Controls, FM1596; Rail Systems, FM0787; and Junction Boxes FM1597. All installation of controls, protection devices and wiring should be done by a qualied licensed electrician. All electrical and safety codes should be followed including the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA). RESERVE POWERED DESIGN For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump. *All single phase units require external starting capacity and relay circuits. LITERS 0 0 50 100 400 150 200 800 250 300 1200 350 1600 400 450 500 550 2000 650 GALLONS 5 2 10 15 4 6 20 25 8 30 10 35 12 40 14 45 50 16 55 18 60 70 FLOW PER MINUTE T O T A L
D Y N A M I C
H E A D M E T E R S F E E T PUMP PERFORMANCE CURVE MODELS 611/621/631/641/651/661 611 621 631 641 651 661 2400 600 65 20 013859B 013859A MODEL Feet Shut-off Head: 611 621 631 641 651 661 Meters Gal. Liters 5 1.5 255 965 340 1287 385 1457 480 1816 575 2176 -- -- 10 3.0 190 719 277 1048 330 1249 430 1627 533 2017 600 2271 15 4.6 110 416 215 813 275 1040 380 1438 490 1854 560 2119 20 6.1 35 132 143 541 220 832 325 1230 440 1665 515 1949 25 7.6 -- -- 72 272 150 567 270 1022 390 1476 475 1798 30 9.1 -- -- -- 80 302 208 787 335 1268 430 1627 35 10.7 -- -- -- 143 541 280 1059 383 1449 40 12.2 -- 72 272 220 832 330 1249 45 13.7 -- -- 150 568 280 1059 50 15.2 80 302 220 832 55 16.7 -- -- 150 568 60 18.3 85 321 Gal. Liters Gal. Liters Gal. Liters Gal. Liters Gal. Liters 22 ft.(6.7m) 29 ft.(8.8m) 35 ft.(10.7m) 44 ft.(13.4m) 55 ft.(16.8m) 65 ft.(19.8m) -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 3 Copyright 2007 Zoeller Co. All rights reserved. 3" Vertical Discharge Weight 245 lbs. 3" Flanged Discharge Weight 245 lbs. 4" Horizontal Discharge Weight 245 lbs. ZEPA0468A O N I T A T R O 8 5/16 5 1/4 2 5/8 3"-8 NPT 9 1/8 17 9/16 6 5/16 29 1/4 FOR SIZE ONLY. VOLUME MAY REQUIRE LARGER BASIN. SIMPLEX INSTALLATION 3 INCH CHECK VAVLE P/N 30-0160 ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED SIMPLEX DUPLEX 24 INCH MINIMUM 30 INCH MINIMUM BASIN DIAMETER .68 <20 FLA DIAMETER >20 .96 (BY OTHERS) 3 INCH NIPPLE FLANGED ELBOW STANDARD 3 INCH 90 (BY OTHERS) 10 3/4 HOLE WEEP 29 1/4 5 1/4 2 5/8 15 15/16 P/N 30-0160 3 INCH UNICHECK 15 1/8 SIMPLEX INSTALLATION T 9 5/8 R O T I O N A 6 5/16 (BY OTHERS) 3 INCH-8 NPT FLANGE ALL DIMENSIONS IN INCHES UNLESS OTHERWISE NOTED 36 INCH MINIMUM 30 INCH MINIMUM LARGER BASIN. VOLUME MAY REQUIRE FOR SIZE ONLY. DUPLEX SIMPLEX BASIN DIAMETER DIAMETER .96 >20 FLA <20 .68 ZEPA0467A ZEPA0470A 11 3/4 5 1/4 2 5/8 29 1/4 STD. 4 INCH-90 ELBOW SIMPLEX INSTALLATION N O I T A TOR 11 17 5/16 17 5/8 6 5/16 4 INCH P/N 6030-0194 48 INCH MINIMUM 30 INCH MINIMUM LARGER BASIN. VOLUME MAY REQUIRE FOR SIZE ONLY. DUPLEX SIMPLEX BASIN DIAMETER DIAMETER .96 >20 FLA <20 .68 CHECK VALVE 4 Copyright 2007 Zoeller Co. All rights reserved. 2 13 5/64 3/4 12 4 INCH CHECK VALVE (BY OTHERS) 2" GUIDE RAIL 7 5 1 30 3/8 1 5/64 6 1/2 3 7/8 L I F T I N G
H E I G H T
=
4 4
1 / 4 ( W I T H
C A B L E
C O N N E C T O R ) ( W I T H O U T
C A B L E
C O N N E C T O R ) L I F T I N G
H E I G H T
=
4 0
1 / 4 30 1/2 SIMPLEX INSTALLATION .1/2 - 2 HOLES 20 (OPTIONAL) S.S. OR GALV. STL. CABLE CONNECTOR O N I O T A T R 17 1/8 12 5/8 >20 .96 DIAMETER FLA <20 .68 DOOR FRAME REF. PLANE 24 3/4 5 1/16 4 INCH-125 LB ANSI FLANGE LIFTING CABLE S.S. OR GALV. STL. (OPTIONAL) LARGER BASIN. VOLUME MAY REQUIRE FOR SIZE ONLY. DIAMETER 60 INCH MINIMUM 36 INCH MINIMUM DUPLEX BASIN SIMPLEX MINIMUM FOR SIZE ONLY. VOLUME MAY REQUIRE LARGER BASIN. 48 INCH DIAMETER DIMENSIONS BASED ON STD. ANSI FITTING SIZES DUPLEX INSTALLATION CHECK VALVES REQUIRED, NOT SHOWN FOR CLARITY 5 3/8 P/N 30-0160 WEEP HOLE ( W I T H O U T
C A B L E
C O N N E C T O R ) L I F T I N G
H E I G H T
=
4 5
1 / 4 L I F T I N G
H E I G H T
=
4 1
1 / 4 ( W I T H
C A B L E
C O N N E C T O R ) 8 32 (OPTIONAL) S.S. OR GALV. STL. LIFTING CABLE 3 INCH UNICHECK .48 (OPTIONAL) S.S. OR GALV. STL. (OPTIONAL) CABLE CONNECTOR SIMPLEX INSTALLATION 15 15/16 9 5/8 N O OR TAT I 6 5/16 MINIMUM FOR SIZE ONLY. VOLUME MAY REQUIRE LARGER BASIN. 42 INCH DIAMETER 3 TWO 1/2 HOLES 3 INCH NIPPLE (BY OTHERS) PIPE (BY OTHERS) 2 INCH S.S OR GALV. STL. ALL DIMENSIONS IN INCHES UNLESS OTHERWISE NOTED .96 >20 <20 .68 DIAMETER FLA DOOR FRAME REF. PLANE DOOR FRAME REF. PLANE O T TA N O I R N T TA O I OR HOR. RAIL SYSTEM 2 1/2 - 3 INCH 14 1/8 30 1/8 3 3/8 25 1/4 14 1/2 27 1/8 5/8 9 5/8 RAIL SYSTEM DIMENSIONAL DATA 3" Vertical 39-0074 & 39-0075 3" Horizontal 39-0094 4" Horizontal 39-0016 ZEPA0472A ZEPA0469A L I F T I N G
H E I G H T
=
4 0
7 / 1 6 ( W I T H O U T
C A B L E
C O N N E C T O R ) ( W I T H
C A B L E
C O N N E C T O R ) L I F T I N G
H E I G H T
=
4 4
7 / 1 6 (BY OTHERS) 3 INCH COUPLING 3 INCH MALE NPT 3/8 4 1/16 30 11/16 6 11/16 (BY OTHERS) 3 INCH NIPPLE PIPE (BY OTHERS) 3/4 INCH S.S. OR GALV. STL. P/N 6030-0160 3 INCH UNICHECK WEEP HOLE 1 1/2 TWO 3/8 HOLES 3 1/4 DIAMETER >20 <20 FLA .96 .68 S.S. OR GALV. STL. CABLE CONNECTOR S.S. OR GALV. STL. (OPTIONAL) LIFTING CABLE (OPTIONAL) 9 1/8 17 13/16 15 7/16 SIMPLEX INSTALLATION 25 3/4 I A T O N T R O 36 INCH MINIMUM 30 INCH MINIMUM FOR SIZE ONLY. VOLUME MAY REQUIRE LARGER BASIN. BASIN DUPLEX SIMPLEX 6 5/16 DIAMETER DOOR FRAME REF. PLANE 22 5/8 ZEPA0533A
Gas-Engines and Producer-Gas Plants
A Practice Treatise Setting Forth the Principles of Gas-Engines and Producer Design, the Selection and Installation of an Engine, Conditions of Perfect Operation, Producer-Gas Engines and Their Possibilities, the Care of Gas-Engines and Producer-Gas Plants, with a Chapter on Volatile Hydrocarbon and Oil Engines