Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
95 views

Calc Wind Loads FPIP

The document provides wind load calculations for a 10m tall truss structure and 8m tall wall structure. It includes data on structure dimensions, exposure conditions, and wind speed. Calculations are shown to determine wind pressure coefficients and resultant wind loads on the structures. For the truss, maximum wind suction of -7.8198 kN/m is calculated for the windward side. For the wall, a maximum wind load of 10.4488 kN/m is found for the windward wall, while the side walls see a load of -9.4161 kN/m.

Uploaded by

George Georgian
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
95 views

Calc Wind Loads FPIP

The document provides wind load calculations for a 10m tall truss structure and 8m tall wall structure. It includes data on structure dimensions, exposure conditions, and wind speed. Calculations are shown to determine wind pressure coefficients and resultant wind loads on the structures. For the truss, maximum wind suction of -7.8198 kN/m is calculated for the windward side. For the wall, a maximum wind load of 10.4488 kN/m is found for the windward wall, while the side walls see a load of -9.4161 kN/m.

Uploaded by

George Georgian
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 4

WIND LOAD - TRUSS

(Reference: NSCP 2001)


height (m) : 10 m
slope, : 3
truss spacing: 5 m
exposure: C
V (kph): 200 kph for V, see Fig 207-1, p 2-23
I
w
: 1.15 for I
w
, see Table 207-2, p 2-18
K
z
: 1 for K
z
, see Table 207-3, p 2-18
K
1
: 0.09 for multipliers K
1
,K
2
,K
3
see Figure 207-2, p 2-24
K
2
: 1
K
3
: 1
K
zt
: 1.19 for K
zt
, see Equation 207-2, p 2-20
G: 0.85 for G, see Section 207.6, p 2-20
C
p
: windward (-) -0.5 for C
p
, see Fig 207-3, p 2-25
(+) 0.1
C
p
for roof overhang: 0.8 see Section 207.7.2
leeward : -0.5
GC
pi
: (+) 0.18 for GC
pi
, see Table 207-4, p 2-19
(-) -0.18
qh: 2.59 KPa for q
h
& q
z
, see Equation 207-1, p 2-18
live load: 0.60 KPa for roof live loads, see Table 205-3, p 2-10
For Deadload:
roofing: 0.1 KPa
ceiling & utilities: 0.24 KPa
purlins: 0.10 KPa
windload computation for buildings of all heights
a) at windward side:
case 1: Cp
(-)
p
GCpi(+)
= -7.8198 KN/m
p
GCpi(-)
= -3.1667 KN/m
case 2: Cp
(+)
p
GCpi(+)
= -1.2279 KN/m
p
GCpi(-)
= 3.4252 KN/m
b) at leeward side:
p
GCpi(+)
= -7.8198 KN/m
p
GCpi(-)
= -3.1667 KN/m
finally, use:
at windward side (case 1): -7.8198 KN/m (suction)
Data:
For Windload:
For Liveload:
Calculations:
Windload:
(case 2): 3.4252 KN/m (downward)
at leeward side: -7.81983 KN/m (suction)
on top chord: 3 KN/m
on top chord: 1 KN/m
on bottom chord: 1.2 KN/m
Deadload:
Liveload:
WIND LOADS -WALL
(Reference: NSCP 2001)
wall height (m) : 8 m
truss spacing: 5 m
exposure: C
V (kph): 200 kph for V, see Fig 207-1, p 2-23
I
w
: 1.15 for I
w
, see Table 207-2, p 2-18
K
z
: 0.94 for K
z
, see Table 207-3, p 2-18
K
1
: 0.09 for multipliers K
1
,K
2
,K
3
see Figure 207-2, p 2-24
K
2
: 1
K
3
: 1
K
zt
: 1.19 for K
zt
, see Equation 207-2, p 2-20
G: 0.85 for G, see Section 207.6, p 2-20
C
p
: windward (-) 0 for C
p
, see Fig 207-3, p 2-25
(+) 0.8
leeward : -0.5
side walls: -0.7
GC
pi
: (+) 0.18 for GC
pi
, see Table 207-4, p 2-19
(-) -0.18
qh: 2.43 KPa for q
h
& q
z
, see Equation 207-1, p 2-18
windload computation for buildings of all heights
a) windward wall:
case 1: Cp
(-)
p
GCpi(+)
= -2.1870 KN/m
p
GCpi(-)
= 2.186968 KN/m
case 2: Cp
(+)
p
GCpi(+)
= 6.07491 KN/m
p
GCpi(-)
= 10.4488 KN/m
b) leeward wall:
p
GCpi(+)
= -7.35064 KN/m
p
GCpi(-)
= -2.97671 KN/m
b) at side walls:
-9.41611 KN/m
finally, use:
at windward wall (case 1): 2.1870 KN/m
(case 2): 10.4488 KN/m
at leeward wall: -7.35064 KN/m
side walls: -9.4161 KN/m
Windload:
Data:
For Windload:
Calculations:
wx
wy