Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

DM130 Flyer E

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Analogue modem for

remote meter reading


DM130

The DM130 modem makes remote reading of meters


with serial interfaces possible via analogue telephone
lines.
The meter data (energy register, load profiles) will be transmitted in transparent
mode via different interfaces. Using this modem other data collectors can be
read out too. An additional power supply for devices with battery is available.

Features

Wide range power supply


100-230 VAC

Time window for calls received

Internal clock with back-up

Applicable in analogue telephone


networks

Password protection

Status of operational mode through


LED:
- Power : Operating / Online
- Status : Boot / Errors

Transparent readout of the meter


data

Programming locally via DIP


switches or remotely via phone line

Upgrade of firmware locally via


RS232 interface

Serial Interfaces:
- CL1 acc. to EN62056-21 up to
19,2 kBit/s
- RS232 up to 19,2kBit/s
- RS485 max. 32 Transceiver,
19,2 kBit/s
- The interfaces are working in
parallel. The baudrate and data
format are the same for all interfaces.
Auxiliary power supply

Housing
The housing of the modem is designed
according to DIN 43861-2 (to be
mounted onto a meter board or terminal cover).

Technical data
Power Supply:

Modifications or deviations are reserved Rev. 1.4


Voltage range

100 - 230V AC, 50Hz

Power consumption

approx. 10 VA active, ca. 6 VA passiv

Telephone connection :

Interfaces:

Telecom-approval acc. to CTR21,


EG 201121
V.22bis, V.32, V.32bis, (2,4 to 14,4 kbit/s),
Data protection acc. to V.42, MNP4
Data decoding acc. V.42bis, MNP5
Meter connection

CL1 (20 mA ) according to EN 62056-21 Mode C up to


19,2 kbit/s
RS232 up to 19,2 kBit/s, fullduplex, (Rx, Tx, GND, DTR)
via RJ-11 connector
RS485 up to 32 Transceiver, 2-wire, 19,2 kBit/s, 1000m
cable length
fixed baudrate or baudrate switching (Mode C)
data format: 8N1 or 7E1

Auxiliary power supply


Climatic conditions:

9 VDC / 100 mA
Operating temperature
Storage temperature
Humidity range

Protection type:
Dimensions:

-10 ... +55C


-20 ... +80C
0 - 95 % relativ, non condensing
IP 51

Terminal coveror meter board

Elster GmbH
Steinern Strae 19-21
55252 Mainz-Kastel
Germany
Phone +49 (0) 6134 / 605-777
Fax
+49 (0) 6134 / 605-750
e-info@de.elster.com
www.elstermesstechnik.com / www.elster.com

H=180mm, W=105mm, T=70mm