Lombardini Gen-Set Specification: Engine Rating Guide
Lombardini Gen-Set Specification: Engine Rating Guide
Lombardini Gen-Set Specification: Engine Rating Guide
NB RATING
(INTERMITTENT) ISO
3046 IFN KW-Hp
GIVEN
ALTERNATOR
EFFICIENCY
(%)
INTERMITTENT
CONTINUOUS
KVA
KW
KVA
KW
14.40 - 19.60
85
15.3
12.2
13.7
11
3.60 - 4.90
80
3.6
2.9
3.3
2.6
SAE j609
5.80 - 7.88
80
5.8
4.6
5.5
4.4
SAE j609
6.30 - 8.57
80
6.0
4.8
5.7
4.6
SAE j609
7.70 - 10.47
80
7.7
6.1
7.3
5.8
SAE j609
15 LD 225
3.30 - 5.00
75
3.1
2.5
2.9
2.3
SAE j609
15 LD 315
4.60 - 6.25
80
4.6
3.6
4.1
3.3
SAE j609
15 LD 350
5.10 - 6.93
80
5.1
4.1
4.7
3.8
SAE j609
6 LD 400
5.90 - 8.02
80
5.9
4.7
5.4
4.3
SAE j609
SAE j609
SAE j609
ENGINE MODEL
GASOLINE
LIQUID LGW 627
COOLED
LGA 226
GASOLINE IM 359
AIR
LGA 280 OHC
COOLED
LGA 340 OHC
DIESEL
AIR
COOLED
DIESEL
LIQUID
COOLED
ELECTRICAL POWER
FLANGING
SAE 5 - 6.5"
15 LD 400 (A)
6.80 - 9.24
80
6.7
5.4
6.0
4.8
6 LD 435
6.70 - 9.11
82
6.9
5.5
6.3
5.0
15 LD 440 (A)
7.40 - 10.06
82
7.5
6.0
6.8
5.4
SAE j609
12 LD 435 - 2
13.20 - 17.95
85
14.0
11.2
13.0
10.4
CONO 30*
11.00 14.95
85
11.7
9.3
8.4
9.2
SAE 5 - 6.5"
12.00 16.30
85
12.7
10.2
11.5
9.2
SAE 5 - 6.5"
16.05 22.44
85
17.5
14.0
15.7
12.6
SAE 5 - 6.5"
17.50 - 23.80
85
18.6
14.9
16.7
13.4
SAE 5 - 6.5"
22.00 29.92
85
23.4
18.7
21.0
16.8
SAE 5 - 6.5"
24.00 - 32.60
85
25.2
20.4
23.0
18.4
SAE 5 - 6.5"
28.50 - 38.76
85
30.0
24.2
27.2
21.8
SAE 5 - 6.5"
Power rated according to ISO 3046 IFN rules, after running -in period
+ / - 5% allowance is to be considered on above rated power outputs
Continuous power output can be overloaded by 10 %.
Intermittent power output cannot be overloaded
Regarding liquid cooled engines, the power output is considered for engines complete with fan
ENGINE MODEL
GASOLINE
LIQUID LGW 627
COOLED
DIESEL
AIR
COOLED
ELECTRICAL POWER
INTERMITTENT
CONTINUOUS
KVA
KW
KVA
KW
9.0
7.2
8.1
6.5
FLANGING
8.50 - 11.60
85
4 LD 820
8.27 - 11.24
81
8.4
6.7
7.6
6.1
CONO 30
9 LD 625 - 2
13.53 - 18.40
85
14.4
11.5
12.8
10.3
SAE 4 - 7.5"
5 LD 825 - 2/L
16.91 - 22.99
86
18.2
14.5
16.2
13.0
SAE 4 - 7.5"
11 LD 626 - 3
20.07 - 27.29
85
21.3
17.1
19.2
15.4
SAE 4 - 7.5"
5 LD 825 - 3/L
25.00 - 34.00
89
27.8
22.3
25.4
20.3
SAE 3 - 11.5"
5 LD 930 - 3
30.15 - 41.00
89
33.5
26.8
31.9
25.5
SAE 3 - 11.5"
5 LD 825 - 4/L
33.80 - 45.96
93
39.3
31.4
35.0
28.0
SAE 3 - 11.5"
5 LD 930 - 4
40.80 - 55.48
93
47.4
37.9
45.2
36.2
SAE 3 - 11.5"
6.00 8.16
85
6.5
5.1
5.8
4.6
SAE 5 - 6.5"
6.50 - 8.80
85
6.9
5.5
6.2
4.9
SAE 5 - 6.5"
9.00 12.24
85
9.5
7.7
8.6
6.9
SAE 5 - 6.5"
DIESEL
LIQUID
COOLED
NB RATING
GIVEN
(INTERMITTENT) ISO ALTERNATOR
3046 IFN KW-Hp
EFFICIENCY
SAE 5 - 6.5"
10.00 - 13.60
85
10.6
8.5
9.6
7.6
SAE 5 - 6.5"
12.00 16.32
85
12.5
10.2
11.3
9.3
SAE 5 - 6.5"
13.00 - 17.70
85
13.8
11
12.5
10
SAE 5 - 6.5"
15.50 - 21.08
85
16.5
13.2
14.9
11.9
SAE 5 - 6.5"
16.00 - 21.76
86
17.2
13.8
15.5
12.42
SAE 5 - 7.5"
21.00 - 28.56
86
22.5
18
20.3
16.2
SAE 5 - 7.5"
22.50 - 30.60
86
24.0
19.3
21.7
17.4
SAE 5 - 7.5"
27.00 - 36.72
86
29.0
23.2
26.2
21
SAE 5 - 7.5"
29.00 - 39.00
86
31.2
25.0
28.1
22.5
SAE 5 - 7.5"
Power rated according to ISO 3046 IFN rules, after running -in period
+ / - 5% allowance is to be considered on above rated power outputs
Continuous power output can be overloaded by 10 %.
Intermittent power output cannot be overloaded
Regarding liquid cooled engines, the power output is considered for engines complete with fan
GASOLINE
LIQUID
COOLED
ENGINE MODEL
LGW 627
LGA 226
GASOLINE
AIR COOLED LGA 280 OHC
LGA 340 OHC
15 LD 225
DIESEL AIR
COOLED
DIESEL
LIQUID
COOLED
NB RATING
ELECTRICAL POWER
GIVEN
(INTERMITTENT) ALTERNATOR
INTERMITTENT CONTINUOUS
ISO 3046 IFN
EFFICIENCY
KVA
KW
KVA
KW
KW-Hp
FLANGING
13.40 - 18.20
85
14.2
11.4
12.8
10.2
SAE 5 - 6.5"
3.20 - 4.30
80
3.2
2.6
3.0
2.4
SAE j609
5.60 - 7.62
80
5.6
4.5
5.1
4.1
SAE j609
6.90 - 9.38
80
6.9
5.5
6.6
5.3
SAE j609
3.00 - 4.80
75
2.8
2.2
2.6
2.1
SAE j609
SAE j609
15 LD 315
4.00 - 5.44
80
4.0
3.2
3.6
2.9
15 LD 350
4.65 - 6.32
80
4.6
3.7
4.3
3.5
SAE j609
6 LD 400
5.50 - 7.48
80
5.5
4.4
5.0
4.0
SAE j609
15 LD 400
6.20 - 8.43
80
6.2
5.0
5.6
4.5
SAE j609
6 LD 435
6.43 - 8.74
82
6.6
5.3
5.9
4.8
SAE j609
15 LD 440 (A)
6.80 - 9.25
82
7.0
5.6
6.2
5.0
SAE j609
3 LD 510
7.35 - 9.99
82
7.5
6.0
6.8
5.4
CONO 24
7 LD 665
9.90 - 13.46
85
10.5
8.4
9.8
7.8
CONO 30
12 LD 435 2
12.65 - 17.20
85
13.4
10.8
12.1
9.7
SAE j609
12 LD 475 2
14.85 - 20.19
85
15.8
12.6
14.4
11.5
SAE j609
9 LD 625 2
19.12 - 26.00
85
20.3
16.3
18.8
15.0
** STD LOMBARDINI
11 LD 626 3
28.67 - 38.99
85
30.5
24.4
27.9
22.3
** STD LOMBARDINI
10.5 - 14.28
85
11.0
8.9
10.0
8.0
SAE 5 - 6.5"
11.50 - 15.60
85
12.2
9.7
10.9
8.7
SAE 5 - 6.5"
15.5 - 21.08
85
16.5
13.2
15.0
12.0
SAE 5 - 6.5"
16.50 - 22.40
85
17.5
14
15.7
12.6
SAE 5 - 6.5"
21.0 - 28.56
85
22.3
17.8
20.0
16.0
SAE 5 - 6.5"
23.00 - 31.30
85
24.5
19.5
21.9
17.5
SAE 5 - 6.5"
27.50 - 37.40
85
29.0
23.4
26.5
21.3
SAE 5 - 6.5"
25.00 - 34.00
86
26.8
21.5
24.2
19.3
SAE 4 - 7.5"
33.00 - 44.88
86
35.5
28.4
32.0
25.5
SAE 4 - 7.5"
35.00 - 47.60
86
37.6
30.1
33.7
27
SAE 4 - 7.5"
43.00 - 58.48
86
46.2
37
42.0
33.5
SAE 4 - 7.5"
46.00 - 62.50
86
49.5
39.6
44.5
35.06
SAE 4 - 7.5"
Power rated according to ISO 3046 IFN rules, after running -in period
+ / - 5% allowance is to be considered on above rated power outputs
Continuous power output can be overloaded by 10 %.
Intermittent power output cannot be overloaded
Regarding liquid cooled engines, the power output is considered for engines complete with fan
ENGINE
TYPE
ENGINE MODEL
GASOLINE
LIQUID LGW 627
COOLED
DIESEL
LIQUID
COOLED
FLANGING
6.5 - 8.8
85
6.9
5.5
6.2
SAE 5 - 6.5"
6.70 - 9.11
81
6.8
5.4
6.1
4.9
CONO 30
9 LD 625 - 2
10.73 - 14.59
85
11.4
9.1
10.4
8.3
SAE 4 - 7.5"
5 LD 825 - 2/L
13.70 - 18.63
86
14.7
11.8
13.0
10.4
SAE 4 - 7.5"
11 LD 626 - 3
16.70 - 22.71
85
17.7
14.2
15.4
12.3
SAE 4 - 7.5"
5 LD 825 - 3/L
20.70 - 28.15
89
23.0
18.4
20.6
16.5
SAE 3 - 11.5"
5 LD 930 - 3
24.50 - 33.32
89
27.3
21.8
26.2
20.9
SAE 3 - 11.5"
5 LD 825 - 4/L
28.00 - 38.08
93
32.6
26.0
29.5
23.6
SAE 3 - 11.5"
5 LD 930 - 4
33.82 - 45.99
93
39.3
31.5
36.8
29.4
SAE 3 - 11.5"
5.00 - 6.80
80
5.0
4.0
4.5
3.6
SAE 5 - 6.5"
5.50 - 7.5
80
5.5
4.4
5.0
4.0
SAE 5 - 6.5"
SAE 5 - 6.5"
4 LD 820
DIESEL
AIR
COOLED
ELECTRICAL POWER
NB RATING
GIVEN
(INTERMITTENT) ISO ALTERNATOR INTERMITTENT
CONTINUOUS
3046 IFN KW-Hp
EFFICIENCY
KVA
KW
KVA
KW
7.50 - 10.2
80
7.5
6.0
7.0
5.5
8.50 - 11.50
80
8.5
6.8
7.6
6.1
SAE 5 - 6.5"
10.00 - 13.6
85
10.5
8.5
9.5
7.5
SAE 5 - 6.5"
11.00 - 15.00
85
11.6
9.3
10.5
8.4
SAE 5 - 6.5"
13.00 - 17.68
85
14.0
11.0
12.5
10.0
SAE 5 - 6.5"
13.50 - 18.36
86
14.5
11.5
12.5
10.0
SAE 5 - 7.5"
18.00 - 24.48
86
19.3
15.5
17.5
14.0
SAE 5 - 7.5"
19.50 - 26.50
86
21.0
16.8
19.5
15.1
SAE 5 - 7.5"
23.00 - 31.28
86
24.7
19.8
22.5
18.0
SAE 5 - 7.5"
24.50 - 33.30
86
26.2
21.0
23.8
19.0
SAE 5 - 7.5"
Power rated according to ISO 3046 IFN rules, after running -in period
+ / - 5% allowance is to be considered on above rated power outputs
Continuous power output can be overloaded by 10 %.
Intermittent power output cannot be overloaded
Regarding liquid cooled engines, the power output is considered for engines complete with fan