Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

UBE Air Drying Membranes

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

DM Series

UM Series
57

Module Structure Air Dryer


Fixed Purge Orifice Type (DM Series)
Compressed Air

Product Gas

(Feed Gas)

(Non-Permeate Gas)

Dried Air

Wet Air

Purge Orifice
(Purge Inlet)

Purge Outlet
(Permeate Gas)

H2O

Compressed Air

H2O

(Feed Gas)
Wet Air

Purge Air

Product Gas
(Non-Permeate Gas)

H2O

Dried Air
H2O
Polyimide Hollow Fiber
58

Module Structure Air Dryer


Sweep Adjustment Valve Type (UM Series)
Compressed Air

Product Gas

(Feed Gas)

(Non-Permeate Gas)

Dried Air

Wet Air
Purge Outlet

Purge Air

(Permeate Gas)

H2O

Compressed Air

H2O

(Feed Gas)
Wet Air

Purge Air

Product Gas
(Non-Permeate Gas)

H2O

Dried Air
H2O
Polyimide Hollow Fiber
59

Membrane Material & Its Feature


Type :

Asymmetrical Hollow Membrane

Material :

Aromatic Polyimide

General Operating Condition :


TG > 300 C
Ambient Temperature :
5 ~ 80 C for Air Dryer
Operation Temperature :
5 ~ 60 C for Air Dryer
Operation Pressure :
0.4 ~ 1.0 MPaG for Air Dryer
Feature :

(1) High Permeation Flux


(2) Good Selectivity
(3) Excellent Durability

60

Air Dryer / Ideal System Connection


Example of Direct Use
Connecting to Compressor

After
Cooler

Inlet Air

DM Series

Pressure
Gauge

(Fixed Purge Orifice)

Air
Filter

Mist
Filter

UBE

Flow
Adjustment
Valve

Product
Dried Air

Compressor

Purge Outlet

or
Compressed Air

Example of branched use from


Compressed-Air Piping

Pressure
Regulator

Stop
Valve

61

Air Dryer / Ideal System Connection


Example of Direct Use
Connecting to Compressor

After
Cooler

Inlet Air

UM Series
(Purge Adjustment Valve)

Air
Filter

Pressure
Gauge

Flow
Adjustment
Valve

Product
Dried Air

Mist
Filter
Purge
Adjustment
Valve

Compressor

or
Compressed Air

Example of branched use from


Compressed-Air Piping

Purge Outlet

Pressure
Regulator

Stop
Valve
62

Durability against Contaminants


Water / Humidity: Liquid water should be avoided
and less than 80 RH%
Small Particles: As few as possible, less than 0.01 m
Residual Oil:
< 0.01mg/Nm3 (< 0.008 ppm w/w)
Hydrocarbons:

< 0.013mg/Nm3 (< 0.01 ppm w/w)

H2S:

< 3 vol%

NH3 & Amines:

< 100 vppm

Acid:

Should be avoided

Aromatics:

As low as possible

Alcohol:

Good
63

Advantage as compared with PSA


Simple Module structure and Flexible System Design
Lightweight and Compact
No prescribed direction to be connected
- You can set a membrane dryer every directions
(Vertical , Horizontal or Diagonally)

No electric power required


- No control units and various parts driven by electric power
are required

Maintenance is very easy !!


64

You might also like