Boiler Funda
Boiler Funda
Boiler Funda
SABARI GIRISH N
SR. ENGINEER (O)
SESSION PLAN
Boiler
fundamentals
Principle
of Combustion
Classification
of Boilers
Arrangement
of main boiler
WHAT IS A BOILER?
BOILER
BOILER FUNDAMENTALS
STEAM
WATER
COAL
FLUE GAS
BOILER
AIR
ASH
COMBUSTION EQUATIONS..
C +O2
CO2
33820 KJ/Kg
2C+O2
2CO
10200 KJ/Kg
2H+O2
H2O
S +02
SO2
COMBUSTION EQUATIONS..
=4.31[(8/3)C 8(H-0/8)-S]
AIR REQUIRED
EXCESS AIR
O2 - 23% by weight
O2- 21% by volume
3Ts
temperature
time
Turbulance
COMBUSTION EFFICIENCY
Design of the boiler
Fuel used
Skill of obtaining combustion with
minimum excess air ( CO monitoring)
EFFICIENCY CALCULATION
METHODS
DIRECT METHOD
IN-DIRECT METHOD
CLASSIFICATION OF BOILERS
BASED ON ARRANGEMENT
FIRE TUBE
WATER TUBE
CLASSIFICATION OF BOILERS
FIRING ARRANGEMENT
FRONT FIRED
CORNER /TANGENTIAL FIRED
GRATE FIRED
PULVERIZED FUEL FIRED
CIRCULATION
NATURAL CIRCULATION
FORCED CIRCULATION
CLASSIFICATION OF
BOILERS
APPLICATION
UTILITY BOILERS
INDUSTRIAL BOILERS
CONSTRUCTION
TOWER TYPE
TWO PASS BOILERS
MANUFACTURERS
CE-BHEL
ANSOLDO
LMZ
COMPONENTS OF A BOILER
ECONOMISER
BOILER DRUM
DOWN COMERS
WATER WALL
PRIMERY SUPER HEATER
PLATEN SUPER HEATER
FINAL SUPER HEATER
RE-HEATER
BURNER
OIL GUNS
IGNITORS
BUCK STAYS
STAGE-I
ECONOMISER
NO STEAM FORMATION
BOILER DRUM
WATER WALL
SUPER HEATER
RAISE STEAM TO HIGHER TEMPERATURE
ARRANGED IN 3 STAGES
RE HEATER
BURNERS
IGNITORS
SPARKS
DUTY CYCLE
2879.4 T/HR
DIFFERENTIAL PRESSURE
1.948 KSC
SPECIFIC GRAVITY
.5993@362 DEG
BUCKSTAYS
BOILER AUXILIARIES
COAL FEEDERS
MILLS
PRIMARY AIR FANS
SEAL AIR FAN
FORCED DRAFT FANS
WIND BOX
SCANNER FAN
AIR PRE HEATERS
ESP
INDUCED DRAFT FANS
CHIMNEY
SOOT BLOWERS
COMBUSTION
Carbon
Volatile matter
Moisture
Ash
Sulphure
36.54
21.6
10
32
.38
BHEL-(CE DESIGN)
TYPE
EXPLOSION/IMPLOSIO
N CAPACITY
VOLUME
14820 M3
SIZE
62.456MTR
TUBES
OD -51MM THICKNESS-5.6MM,
WT 583.2 TONS
DRUM
CAPACITY
SAFTEY VALVES
TUBE LENGTH
PARAMETERS
Flow
MCR
NCR
S H steam
1725
1384
RH steam
1537
1527
Feed water
1725
1527.3
Spray
22.7
Secondary
1464
1337
Primary air
558
477
Total Air
2021
1814
COAL( 4300
kcal/kg)
296
266
COMPARISON
SL.
NO
PARAMETER
ST.-1
ST.-2
FIRING
FRONT FIRED
CORNER FIRED
CIRCULATION
NATURAL
CONTROLLED
PF
TRANSPORTATION
COMMON PA
FANS-2NOs.
OIL
LFO/HFO
LSHS or HFO
REHEATERS
IN CONVECTIVE ZONE
IN CONV. &
RADIATION ZONE
APHs
SEPARATE APHs
FLY ASHING
CONTINUOUS(u#2 & 3)
INTERMITTENT
BOILER CONTROL
BMS
FSSS
COAL MILL
BOWL
Contd.
SL.
NO
PARAMETER
ST.-1
ST.-2
10
SH/RH TEMP.
CONTROL
ATTEMPERATION &
BURNER TILT
11
DOWN COMERS
12
SECONDARY AIR
CONTROL
NOT POSSIBLE
POSSIBLE
13
MILL CHANGE
OVER
REQUIRE GUNS
SUPPORT
ADJACENT MILL
SUPPORT IS
SUFFICIENT
14
IGNITORS
REQUIRES LFO
SUPPORT
15
16
AIR
PRIMARY AIR,
SECONDARY AIR
Contd.
SL.
NO
PARAMETER
ST.-1
ST.-2
17
FD FAN CONTROL
VANE
CONTROL
BLADE PITCH
CONTROL
18
PA FAN CONTROL
VANE
CONTROL
BLADE PITCH
CONTROL
BOILER DRUM
6 SPRING LOADED
SUPER HEATER
2 SPRING LOADED, 4 ERVs
CRH 4 SPRING LOADED
HRH
4 SPRING LOADED, 4 ERVs
NO
SET PR RESET PR
B1 200
191
4
B2-B6
202- 206
SH 184
178
3
SH ERVs 180-182 176-178 4.8
CRH
55-56 53-55 3
HRH
48.5-49 47-47.5 3
HRH ERVs 47.5-48 46.6-47 1.97
%BLOWDOWN
192-1965
NO BLOWERS
104+34+4
WALL BLOWER
TRAVEL
305
NOZZLE DIA
26
BLOWING PRESSURE
12
TIME
1.44 MIN
RATE
CONSUMPTION
3349 (PER GROUP)
LRSB
9200 mm
32 mm
12.5 ksc
(PER PAIR)
293
COLLECTION EFFICIENCY
TREATMENT TIME
DUST CONCENTRATION
COLLECTING RAPPER FREQUECY
EMITTING RAPPER FREQUECY
HOPPERS
HOPPER CAPACITY
HOPPER HEATERS
FIELD CURRENTS ( mA)
VOLTAGE
99.9%
33.33 SEC
115mg / M3 (LIMIT)
15- 2 RAPS/ HR
10 RAPS /HR
96
8HRS +10%
96X6
150 250 325 450 600 750
70 KV PEAK