1.1 Introduction
1
3.1 Apparatus
2
3.2 Procedure
1. The sprinkler head was inserted into the holder ( make sure the seal tape is used to
prevent leakage at sprinkler heads )
2. Open water inlet valve and water pressure reading was taken.
3. The fire was lighted up by using candle and was put under the sprinkler. ( make sure
the fire is heat up the sprinkler )
4. The sprinkler model door was closed to prevent the fragment and the water form flow
outside.
5. The time taken and the water pressure reading was taken from the sprinkler start to
heat until the bust.
4.0 Result
Type of Sprinkler :
Colour of Liquid used :
Time Taken to Bust:
64 bar
0 bar
Type of Sprinkler
a) Quartzoid Type Head
Orange
- 57
Red
- 68
Yellow
-79
Green
-93
Blue
-141
Mauve
-182
Black
-204 or 260
Contains metal struts soldered together which are used to hold the water valve in place.
At certain temperature, heat from a fire melts the solder and the struts fall away allowing
the head to open
Under heat, the strut part to allow the valve to discharge water on the fire .
The quartzoid bulb sprinkler system is activated by bursting or expansion bulb acted as
valve, thus water sprayed.
A wet pipe sprinkler system is a sprinkler system employing automatic sprinkler heads
attached to a piping system containing water and connected to a water supply so that
water discharges immediately from sprinklers opened by heat from a fire.
Permanently charged with water for instant response when sprinkler head burst.
If there is a burst of town water main from one side, the stop valve of both town water
main and branch pipe can be closed, and water is supply from the other branch pipe.
Figure 5 : Hose Reel for Faculty of Civil engineering in UiTM Pasir Gudang
Components
Drum
Hose
Stop Valve
Nozzle
Details
The hose reel drum is a universal swing type, where the hose
drum rotates around a horizontal shaft and the hose can be
withdrawn from any direction.
The fire hose reel is made of non-kinking, braided rubber type
and the length of the hose is 30 meter.
A 25mm diameter stop valve to BS 1010 is provided for the
connection of the hose reel to the water supply.
The shut off nozzle assembly which is fitted at the end of the
hose is constructed of corrosion resistant material conforming to
BS 336. There are markings to indicate the open/shut positions
of the nozzle
Principle of Operation
to operate the system efficiently, the following instructions should be followed.
1. Ensure the nozzle or jet is in the closed position
2. Turn on the main valve (some will not let the nozzle out until this is done)
3. Reel out the hose, towards the fire
4. Open the nozzle or valve and direct the stream of water at the fire, from a safe
distance.
Discussion
In the discussion, the equipment for sprinkler system have been handle careful due
to avoid any injuries to the student when conduct the demonstration. One of the precaution
steps that have been taken was the sprinkler system have been conduct in the secured
glass. This is to avoid the Quartzoid bulbs glass that have break due to the high
temperature can endangered the students watching around the demonstration. Besides that,
the experiment must be conduct by lecturer or laboratory assistor to avoid any accidents
happen in demonstration. This is because the lecturer or laboratory assistor already know
how to conduct the equipment.
The advantages for sprinkler system installed in the building is because the system
use water as a good medium which protect and give a cooling the object we prevent it from
reaching its ignition point. By this way we can overcome the fire. Besides that, this system
always available 24 hours because the system have automatic progress when fire detect the
smoke and fire.
The disadvantages for this sprinkler system is water that from the sprinkler system
can damaged the electronic things or any equipment in area. This is because water can
conduct the electric that can cause short circuit to electric components.
For the maintenance of the system, the stop valve must closed first. The test valve
can be opened to create flow and cause the non-return section alarm valve to open, to test
the alarm. Regular maintenance of the system consists of greasing the various valves and
checking their freedom of movement, logging the pressure gauge reading, before and after
each alarm valve (thus checking the tightness of the non-return valves) and checking the
alarm system.
The pressure tank level is checked and recharged, if necessary, with fresh water and
air. The centrifugal salt-water pump should also be tested by closing the isolating valves and
draining the pressure switch circuit, when pump should start automatically. Besides that, the
delivery pressure should be logged. In the event of a fire, when a normal situation is
recovered the section and system are drained and flushed out; the recharged with fresh
water and air.
10
Conclusion
From the experiment, we have achieved the objective of the experiment which is to to
understand the basic operation concepts and principles of fire sprinkler system and fire hose
reel in building. In the conclusion, all the operations, functions each components in the
system, advantages and disadvantages of system, and background for this system have
been included to this report. The Quartzoid bulb contained red liquid take about 1 minutes 32
second to break the glass. That means the system have late respond for mercury to expand
and burst to break the sprinkler head.
Besides that, we can conclude from the experiment that this type of sprinkler, the life
span of this sprinkler is about 50 years can be hold if the sprinkler is not burst out. The
sprinkler is being used in the high rise building or large building. There is also many type
sprinkler that is being used in building. From the experiment, we have learn about only three
types of sprinkler.