Scotch Yoke Mechanism
Scotch Yoke Mechanism
Scotch Yoke Mechanism
INTRODUCTION
Multi-operation machine as a research area is motivated by questions that arise in
industrial manufacturing, production planning, and computer control. Consider a large
automotive garage with specialized shops. A car may require the following work, replace
exhaust system, align wheels, and tune up. These three tasks may be carried out in any order.
However, since the exhaust system, alignment, and tune-up shops are in different buildings, it
is impossible to perform two tasks for a car simultaneously. When there are many cars
requiring services at the three shops, it is desirable to construct a service schedule that takes
the least amount of total time.
1.2 Construction
The scotch yoke mechanism is constructed with iron bars. Here the crank is made
in some length and the yoke is also made using the same material. It is noted that the
minimum length of the yoke should be double the length of the crank. The crank and yoke is
connected with a pin. Iron bars are welded to both sides of the yoke to get the reciprocating
motion. The yoke with the iron bars is fixed on the display board with the help of c clamp.
Now the crank is welded to the end of the shaft of the motor. Now the pin on the crank is
connected to the yoke. The pin used to connect yoke and crank is a bolt.
to the initial position. For a complete rotation of crank the yoke moves through a length equal
to double the length of the crank. The displacement of the yoke can be controlled by varying
the length of the crank.
CHAPTER-2
APPARATUS
2.1 Dc motors
At the most basic level, electric motors exist to convert electrical energy into
mechanical energy. This is done by way of two interacting magnetic fields - one stationary,
and another attached to a part that can move. A number of types of electric motors exist, but
most BEAM bots use DC motors 1 in some form or another. DC motors have the potential for
very high torque capabilities (although this is generally a function of the physical size of the
motor), are easy to miniaturize, and can be "throttled" via adjusting their supply voltage. DC
motors are also not only the simplest, but the oldest electric motors.
The basic principles of electromagnetic induction were discovered in the early 1800's
by Oersted, Gauss, and Faraday. By 1820, Hans Christian Oersted and Andre Marie Ampere
had discovered that an electric current produces a magnetic field. The next 15 years saw a
flurry of cross-Atlantic experimentation and innovation, leading finally to a simple DC rotary
motor. A number of men were involved in the work, so proper credit for the first DC motor is
really a function of just how broadly you choose to define the word "motor."
A DC motor is a mechanically commutated electric motor powered from direct
current (DC). The stator is stationary in space by definition and therefore so is its current. The
current in the rotor is switched by the commutator to also be stationary in space. This is how
the relative angle between the stator and rotor magnetic flux is maintained near 90 degrees,
which generates the maximum torque.
DC motors have a rotating armature winding but non-rotating armature magnetic field
and a static field winding or permanent magnet. Different connections of the field and
armature winding provide different inherent speed/torque regulation characteristics. The
speed of a DC motor can be controlled by changing the voltage applied to the armature or by
changing the field current. The introduction of variable resistance in the armature circuit or
field circuit allowed speed control. Modern DC motors are often controlled by power
electronics systems called DC drives.
The introduction of DC motors to run machinery eliminated the need for local steam
or internal combustion engines, and line shaft drive systems. DC motors can operate directly
from rechargeable batteries, providing the motive power for the first electric vehicles. Today
DC motors are still found in applications as small as toys and disk drives, or in large sizes to
operate steel rolling mills and paper machines.
The geometry of the brushes, commutator contacts, and rotor windings are such that
when power is applied, the polarities of the energized winding and the stator magnet(s) are
misaligned, and the rotor will rotate until it is almost aligned with the stator's field magnets.
As the rotor reaches alignment, the brushes move to the next commutator contacts, and
energize the next winding. Given our example two-pole motor, the rotation reverses the
direction of current through the rotor winding, leading to a "flip" of the rotor's magnetic field,
driving it to continue rotating.
The DC Motor or Direct Current Motor to give it its full title, is the most commonly
used actuator for producing continuous movement and whose speed of rotation can easily be
controlled, making them ideal for use in applications were speed control, servo type control,
and/or positioning is required. A DC motor consists of two parts, a "Stator" which is the
stationary part and a "Rotor" which is the rotating part. The result is that there are basically
three types of DC Motor available.
i.
Brushed Motor - This type of motor produces a magnetic field in a wound rotor (the
part that rotates) by passing an electrical current through a commutator and carbon
brush assembly, hence the term "Brushed". The stators (the stationary part) magnetic
field is produced by using either a wound stator field winding or by permanent
ii.
magnets. Generally brushed DC motors are cheap, small and easily controlled
.
Brushless Motor - This type of motor produce a magnetic field in the rotor by using
permanent magnets attached to it and commutation is achieved electronically. They
are generally smaller but more expensive than conventional brushed type DC motors
because they use "Hall effect" switches in the stator to produce the required stator
field rotational sequence but they have better torque/speed characteristics, are more
efficient and have a longer operating life than equivalent brushed types.
iii.
Servo Motor - This type of motor is basically a brushed DC motor with some form of
positional feedback control connected to the rotor shaft. They are connected to and
controlled by a PWM type controller and are mainly used in positional control
systems and radio controlled models.
Normal DC motors have almost linear characteristics with their speed of rotation being
determined by the applied DC voltage and their output torque being determined by the
current flowing through the motor windings. The speed of rotation of any DC motor can be
varied from a few revolutions per minute (rpm) to many thousands of revolutions per minute
making them suitable for electronic, automotive or robotic applications. By connecting them
to gearboxes or gear-trains their output speed can be decreased while at the same time
increasing the torque output of the motor at a high speed.
The magnetic field setup by the rotor tries to align itself with the stationary stator field
causing the rotor to rotate on its axis, but cannot align itself due to commutation delays. The
rotational speed of the motor is dependent on the strength of the rotors magnetic field and the
more voltage that is applied to the motor the faster the rotor will rotate. By varying this
applied DC voltage the rotational speed of the motor can also be varied.
2.3.2 Conventional (Brushed) DC Motor
Since most small DC motors have 3 coils, the coils' current curves will overlay each other,
Added together, this ideal motor's current will then look something like this,
Reality is a bit more complex than this, as even a high-quality motor will display a
current transient at each commutation transition. Since each coil has inductance (by
definition) and some capacitance, there will be a surge of current as the commutator's brushes
first touch a coil's contact, and another as the brushes leave the contact (here, there's a slight
spark as the coil's magnetic field collapses).
As a good example, consider an oscilloscope trace of the current through a Mabuchi
FF-030PN motor supplied with 2 V (1ms per horizontal division, 0.05 mA per vertical
division)
In this case, the peak-to-peak current ripple is approximately 0.29 mA, while the
average motor current is just under 31 mA. So under these conditions, the motor puts about
less than 1% of current ripple onto its power lines (and as you can see from the "clean" traces,
it outputs essentially no high-frequency current noise). Note that since this is a 3-pole motor,
and each coil is energized in both directions over the course of a rotor rotation, one revolution
of the rotor will correspond to six of the above curves (here, 6 x 2.4 ms = 0.0144 sec,
corresponding to a motor rotation rate of just fewer than 4200 RPM).
Motor power ripple can wreak havoc in Nv nets by destabilizing them inadvertently.
Fortunately, this can be mitigated by putting a small capacitor across the motor's power lines
(you'll only be able to filter out "spikey" transients this way, though - you'll always see curves
like the ones above being imposed on your power). On the flip side of this coin, motor power
ripple can be put to good use - as was shown above, ripple frequency can be used to measure
motor speed, and its destabilizing tendencies can be used to reverse a motor without the need
for discrete "back-up" sensors
2.6.4 Characteristics of DC Motor
Voltage in steady state condition
Where:
V = input voltage
Eb = back EMF
Ia = Armature current
R = total resistance
The total resistance R is equal to Armature Resistance (Ra) + External resistance (Rph).
applications. They are smaller, lighter, more efficient and reliable than other singly fed
electric machines.
Originally all large industrial DC motors used wound field or rotor magnets.
Permanent magnets have traditionally only been useful on small motors because it was
difficult to find a material capable of retaining a high-strength field. Only recently have
advances in materials technology allowed the creation of high-intensity permanent magnets,
such as neodymium magnets, allowing the development of compact, high-power motors
without the extra real-estate of field coils and excitation means. But as these high
performance permanent magnets become more applied in electric motor or generator systems,
other problems are realized.
2.6.8 Speed Control
Generally, the rotational speed of a DC motor is proportional to the EMF in its coil (=
the voltage applied to it minus voltage lost on its resistance), and the torque is proportional to
the current. Speed control can be achieved by variable battery tapings, variable supply
voltage, resistors or electronic controls. The direction of a wound field DC motor can be
changed by reversing either the field or armature connections but not both. This is commonly
done with a special set of contactors (direction contactors). The effective voltage can be
varied by inserting a series resistor or by an electronically controlled switching device made
of thrusters, transistors, or, formerly, mercury arc rectifiers.
In a circuit known as a chopper, the average voltage applied to the motor is varied by
switching the supply voltage very rapidly. As the "ON" to "OFF" ratio is varied to alter the
average applied voltage, the speed of the motor varies. The percentage "on" time multiplied
by the supply voltage gives the average voltage applied to the motor. Therefore, with a 100 V
supply and a 25% "on" time, the average voltage at the motor will be 25 V. During the "OFF"
time, the armature's inductance causes the current to continue through a diode called a "fly
back diode", in parallel with the motor. At this point in the cycle, the supply current will be
zero, and therefore the average motor current will always be higher than the supply current
unless the percentage "on" time is 100%. At 100% "on" time, the supply and motor current
are equal. The rapid switching wastes less energy than series resistors. This method is also
called pulse-width modulation (PWM) and is often controlled by a microprocessor. An
output filter is sometimes installed to smooth the average voltage applied to the motor and
reduce motor noise.
Since the series-wound DC motor develops its highest torque at low speed, it is often
used in traction applications such as electric locomotives, and trams. Another application is
starter motors for petrol and small diesel engines. Series motors must never be used in
applications where the drive can fail (such as belt drives). As the motor accelerates, the
armature (and hence field) current reduces. The reduction in field causes the motor to speed
up until it destroys itself. This can also be a problem with railway motors in the event of a
loss of adhesion since, unless quickly brought under control, the motors can reach speeds far
higher than they would do under normal circumstances. This can not only cause problems for
the motors themselves and the gears, but due to the differential speed between the rails and
the wheels it can also cause serious damage to the rails and wheel treads as they heat and cool
rapidly. Field weakening is used in some electronic controls to increase the top speed of an
electric vehicle.
The simplest form uses a contactor and field-weakening resistor; the electronic
control monitors the motor current and switches the field weakening resistor into circuit when
the motor current reduces below a preset value (this will be when the motor is at its full
design speed). Once the resistor is in circuit, the motor will increase speed above its normal
speed at its rated voltage. When motor current increases, the control will disconnect the
resistor and low speed torque is made available.
One interesting method of speed control of a DC motor is the Ward Leonard control.
It is a method of controlling a DC motor (usually a shunt or compound wound) and was
developed as a method of providing a speed-controlled motor from an AC supply, though it is
not without its advantages in DC schemes. The AC supply is used to drive an AC motor,
usually an induction motor that drives a DC generator or dynamo.
The DC output from the armature is directly connected to the armature of the DC
motor (sometimes but not always of identical construction). The shunt field windings of both
DC machines are independently excited through variable resistors. Extremely good speed
control from standstill to full speed, and consistent torque, can be obtained by varying the
generator and/or motor field current. This method of control was the de facto method from its
development until it was superseded by solid state thyristor systems. It found service in
almost any environment where good speed control was required, from passenger lifts through
to large mine pit head winding gear and even industrial process machinery and electric
cranes. Its principal disadvantage was that three machines were required to implement a
scheme (five in very large installations, as the DC machines were often duplicated and
controlled by a tandem variable resistor). In many applications, the motor-generator set was
often left permanently running, to avoid the delays that would otherwise be caused by starting
it up as required.
Although electronic (thyristor) controllers have replaced most small to medium WardLeonard systems, some very large ones (thousands of horsepower) remain in service. The
field currents are much lower than the armature currents, allowing a moderate sized thyristor
unit to control a much larger motor than it could control directly. For example, in one
installation, a 300 amp thyristor unit controls the field of the generator. The generator output
current is in excess of 15,000 amperes, which would be prohibitively expensive (and
inefficient) to control directly with thyristors.
2.6.9 Protection
To extend a D.C. motors service life, protective devices and motor controllers are
used to protect it from mechanical damage, excessive moisture, high dielectric stress and high
temperature or thermal overloading. These protective devices sense motor fault
conditions and either annunciate an alarm to notify the operator or automatically de-energize
the motor when a faulty condition occurs. For overloaded conditions, motors are protected
with thermal overload relays. Bi-metal thermal overload protectors are embedded in the
motor's windings and made from two dissimilar metals. They are designed such that
the bimetallic strips will bend in opposite directions when a temperature set point is reached
to open the control circuit and de-energize the motor.
Heaters are external thermal overload protectors connected in series with the motors
windings and mounted in the motor contactor. Solder pot heaters melt in an overload
condition, which cause the motor control circuit to de-energize the motor. Bimetallic heaters
function the same way as embedded bimetallic protectors. Fuses and circuit breakers are over
current or short circuit protectors. Ground fault relays also provide over current protection.
They monitor the electrical current between the motors windings and earth system ground.
In motor-generators, reverse current relays prevent the battery from discharging and
motorizing the generator. Since D.C. motor field loss can cause a hazardous runaway or over
speed condition, loss of field relays are connected in parallel with the motors field to sense
field current. When the field current decreases below a set point, the relay will deenergize the
motors armature. A locked rotor condition prevents a motor from accelerating after its
starting sequence has been initiated. Distance relays protect motors from locked-rotor faults.
Under voltage motor protection is typically incorporated into motor controllers or starters. In
addition,
motors
transformers, power
can
be
protected
conditioning
from overvoltages or
surges
with
harmonic
solation
filters.
Environmental conditions, such as dust, explosive vapors, water, and high ambient
temperatures, can adversely affect the operation of a DC motor.
To protect a motor from these environmental conditions, the National Electrical
Manufacturers Association (NEMA) and the International Electro technical Commission
(IEC) have standardized motor enclosure designs based upon the environmental protection
they provide from contaminants.
When electrical and DC motor technology was first developed, much of the
equipment was constantly tended by an operator trained in the management of motor systems.
The very first motor management systems were almost completely manual, with an attendant
starting and stopping the motors, cleaning the equipment, repairing any mechanical failures,
and so forth.
The first DC motor-starters were also completely manual, as shown in this image.
Normally it took the operator about ten seconds to slowly advance the rheostat across the
contacts to gradually increase input power up to operating speed. There were two different
classes of these rheostats, one used for starting only, and one for starting and speed
regulation. The starting rheostat was less expensive, but had smaller resistance elements that
would burn out if required to run a motor at a constant reduced speed.
This starter includes a no-voltage magnetic holding feature, which causes the rheostat
to spring to the off position if power is lost, so that the motor does not later attempt to restart
in the full-voltage position. It also has over current protection that trips the lever to the off
position if excessive current over a set amount is detected.
On the first step of the arm, full line voltage is applied across the shunt field. Since the
field rheostat is normally set to minimum resistance, the speed of the motor will not be
excessive; additionally, the motor will develop a large starting torque.
ii.
The starter also connects an electromagnet in series with the shunt field. It will hold the
arm in position when the arm makes contact with the magnet.
iii.
Meanwhile that voltage is applied to the shunt field, and the starting resistance limits the
current to the armature.
iv.
As the motor picks up speed counter - EMF is built up; the arm is moved slowly to short.
2.7.3
Four-Point starter
The four-point starter eliminates the drawback of the three-point starter. In addition to the
same three points that were in use with the three-point starter, the other side of the line, L1, is
the fourth point brought to the starter when the arm is moved from the "Off" position. The
coil of the holding magnet is connected across the line. The holding magnet and starting
resistors function identical as in the three-point starter.
The possibility of accidentally opening the field circuit is quite remote. The four-point
starter provides the no-voltage protection to the motor. If the power fails, the motor is
disconnected from the line.
2.7.4 Energy Losses in DC Motors
Losses occur when electrical energy is converted to mechanical energy (in the motor),
or mechanical energy is converted to electrical energy (in the generator). For the machine to
be efficient, these losses must be kept to a minimum. Some losses are electrical, others are
mechanical. Electrical losses are classified as copper losses and iron losses; mechanical
losses occur in overcoming the friction of various parts of the machine.
Copper losses occur when electrons are forced through the copper windings of the
armature and the field. These losses are proportional to the square of the current. They are
sometimes called I2R losses, since they are due to the power dissipated in the form of heat in
the resistance of the field and armature windings.
Iron losses are subdivided in hysteresis and eddy current losses. Hysteresis losses are
caused by the armature revolving in an alternating magnetic field. It, therefore, becomes
magnetized first in one direction and then in the other. The residual magnetism of the iron or
steel of which the armature is made causes these losses. Since the field magnets are always
magnetized in one direction (dc field), they have no hysteresis losses.
Eddy current losses occur because the iron core of the armature is a conductor
revolving in a magnetic field. This sets up an EMF. across portions of the core, causing
currents to flow within the core. These currents heat the core and, if they become excessive,
may damage the windings. As far as the output is concerned, the power consumed by eddy
currents is a loss. To reduce eddy currents to a minimum, a laminated core usually is used. A
laminated core is made of thin sheets of iron electrically insulated from each other. The
insulation between laminations reduces eddy currents, because it is "transverse" to the
direction in which these currents tend to flow. However, it has no effect on the magnetic
circuit. The thinner the laminations, the more effectively this method reduces eddy current
losses.
2.7.5 Advantages of DC Motor
i.
Speed control over a wide range both above and below the rated speed: The
attractive feature of the dc motor is that it offers the wide range of speed control both
above and below the rated speeds. This can be achieved in dc shunt motors by
methods such as armature control method and field control method. This is one of the
main applications in which dc motors are widely used in fine speed applications such
ii.
iii.
cranes.
Accurate steep less speed with constant torque: Constant torque drives is one such
the drives will have motor shaft torque constant over a given speed range. In such
iv.
v.
Simple drilling machines like hand held portable drilling machines, power feed
drilling machines, etc. are quite common; we can find these machines everywhere. Often
these machines are used for drilling a through hole over the job; these machines cannot be
used for number of machining operations for specific applications. Human force is required
to drill the hole, drilling depth cannot be estimated properly, job may spoil due to human
errors, and different size holes cannot be drilled without changing the drill bit. Consumes lot
of time for doing repeated multiple jobs, these all are the drawbacks. To overcome all these
problems, this automated drilling machine is designed which is aimed to drill the holes
automatically over a job according to the drilling depth data programmed through a key
board. The main concept of this machine is to drill the holes over particular jobs repeatedly at
different depths, sequence is maintained. As the machine contains drill motor, the movement
is controlled accurately.
2.8.2 Drill bit
Drill bits are cutting tools used to create cylindrical holes. Bits are held in a tool
called a drill, which rotates them and provides torque and axial force to create the hole.
Specialized bits are also available for non-cylindrical-shaped holes.
This article describes the types of drill bits in terms of the design of the cutter. The
other end of the drill bit, the shank, is described in the drill bit shank article. Drill bits come
in standard sizes, described in the drill bit sizes article. A comprehensive drill and tap size
chart lists metric and imperial sized drills alongside the required screw tap sizes. The term
drill can refer to a drilling machine, or can refer to a drill bit for use in a drilling machine. In
this article, for clarity, drill bit or bit is used throughout to refer to a bit for use in a drilling
machine, and drill refers always to a drilling machine.
The most common twist drill (the one sold in general hardware stores) has a point
angle of 118 degrees. This is a suitable angle for a wide array of tasks, and will not cause the
uninitiated operator undue stress by wandering or digging in. A more aggressive (sharper)
angle, such as 90 degrees, is suited for very soft plastics and other materials. The bit will
generally be self-starting and cut very quickly. A shallower angle, such as 150 degrees, is
suited for drilling steels and other tougher materials. This style bit requires a starter hole, but
will not bind or suffer premature wear when a proper feed rate is used.
Drills with no point angle are used in situations where a blind, flat-bottomed hole is
required. These drills are very sensitive to changes in lip angle, and even a slight change can
result in an inappropriately fast cutting drill bit that will suffer premature wear.The twist drill
does most of the cutting with the tip of the bit. There are flutes to carry the chips up from the
cutting edges to the top of the hole where they are cast off. Some of the parts of a drill bit are
diagramed below as viewed from the cutting tip of the drill,
the blade to buckle and crack. Cutting on the pull stroke increases the blade tension and will
result in greater control of the cut and longer blade life.
2.9.4 Recommended Teeth per 25mm (tpi) for each material type
2.9.5 Blades
Blades are available in standardized lengths, usually 10 or 12 inches for a standard
hand hacksaw. "junior" hacksaws are half this size. Powered hacksaws may use large blades
in a range of sizes, or small machines may use the same hand blades.
The pitch of the teeth can be anywhere from fourteen to thirty-two teeth per inch (tpi)
for a hand blade, with as few as three tpi for a large power hacksaw blade. The blade chosen
is based on the thickness of the material being cut, with a minimum of three teeth in the
material. As hacksaw teeth are so small, they are set in a "wave" set. As for other saws they
are set from side to side to provide a kerfs or clearance when sawing, but the set of a hacksaw
changes gradually from tooth to tooth in a smooth curve, rather than alternate teeth set left
and right.
Hacksaw blades are normally quite brittle, so care needs to be taken to prevent brittle
fracture of the blade. Early blades were of carbon steel, now termed 'low alloy' blades, and
were relatively soft and flexible. They avoided breakage, but also wore out rapidly. Except
where cost is a particular concern, this type is now obsolete. 'Low alloy' blades are still the
only type available for the junior hacksaw, which limits the usefulness of this otherwise
popular saw.
For several decades now, hacksaw blades have used high speed steel for their teeth,
giving greatly improved cutting and tooth life. These blades were first available in the 'Allhard' form which cut accurately but were extremely brittle. This limited their practical use to
bench work on a work piece that was firmly clamped in a vice. A softer form of high speed
steel blade was also available, which wore well and resisted breakage, but was less stiff and
so less accurate for precise sawing. Since the 1980s, bi-metal blades have been used to give
the advantages of both forms, without risk of breakage. A strip of high speed steel along the
tooth edge is electron beam welded to a softer spine. As the price of these has dropped to be
comparable with the older blades, their use is now almost universal.
2.9.6 Hacksaw blade specifications
The most common blade is the 12 inch or 300 mm length. Hacksaw blades have two
holes near the ends for mounting them in the saw frame and the 12 inch / 300 mm dimension
refers to the center to center distance between these mounting holes.
Blade Width:
Blade Thickness:
The kerf produced by the blades is somewhat wider than the blade thickness due to
the set of the teeth. It commonly varies between 0.030 and 0.063 inches / 0.75 and 1.6 mm
depending on the pitch and set of the teeth. The 10 inch blade is also fairly common and all
the above dimensions apply except for the following:
Hole to Hole:
A panel hacksaw eliminates the frame, so that the saw can cut into panels of sheet
metal without the length of cut being restricted by the frame. Junior hacksaws are the small
variant, while larger mechanical hacksaws are used to cut working pieces from bulk metal.
A power hacksaw (or electric hacksaw) is a type of hacksaw that is powered either by
its own electric motor or connected to a stationary engine. Most power hacksaws are
stationary machines but some portable models do exist. Stationary models usually have a
mechanism to lift up the saw blade on the return stroke and some have a coolant pump to
prevent the saw blade from overheating.
While stationary electric hacksaws are reasonably uncommon they are still produced but saws
powered by stationary engines have gone out of fashion. The reason for using one is that they
provide a cleaner cut than an angle grinder or other types of saw. Large, power hacksaws are
sometimes used in place of a band saw for cutting metal stock to length.
2.10.1 Types
Shapers are mainly classified as standard, draw-cut, horizontal, universal, vertical, geared,
crank, hydraulic, contour and traveling head. The horizontal arrangement is the most
common. Vertical shapers are generally fitted with a rotary table to enable curved surfaces to
be machined (same idea as in helical planning). The vertical shaper is essentially the same
thing as a slotter (slotting machine), although technically a distinction can be made if one
defines a true vertical shaper as a machine whose slide can be moved from the vertical. A
slotter is fixed in the vertical plane.
Small shapers have been successfully made to operate by hand power. As size
increases, the mass of the machine and its power requirements increase, and it becomes
necessary to use a motor or other supply of mechanical power. This motor drives a
mechanical arrangement (using a pinion gear, bull gear, and crank, or a chain over sprockets)
or a hydraulic motor that supplies the necessary movement via hydraulic cylinders.
2.10.2 Operation
A shaper operates by moving a hardened cutting tool backwards and forwards across
the work piece. On the return stroke of the ram the tool is lifted clear of the work piece,
reducing the cutting action to one direction only.
The work piece mounts on a rigid, box-shaped table in front of the machine. The
height of the table can be adjusted to suit this work piece, and the table can traverse sideways
underneath the reciprocating tool, which is mounted on the ram. Table motion may be
controlled manually, but is usually advanced by automatic feed mechanism acting on the feed
screw. The ram slides back and forth above the work. At the front end of the ram is a vertical
tool slide that may be adjusted to either side of the vertical plane along the stroke axis. This
tool-slide holds the clapper box and tool post, from which the tool can be positioned to cut a
straight, flat surface on the top of the work piece. The tool-slide permits feeding the tool
downwards to deepen a cut. This adjustability, coupled with the use of specialized cutters and
tool holders, enable the operator to cut internal and external gear tooth profiles, splines,
dovetails, and keyways.
The ram is adjustable for stroke and, due to the geometry of the linkage, it moves
faster on the return (non-cutting) stroke than on the forward, cutting stroke. This action is via
a slotted link or Whitworth link
CHAPTER-3
FABRICATION
3.1 Frame Work
68.5cm
Breadth:
18.5cm
Height:
71cm
Specifications:
Table diameter:
Supporting link length:
Supporting link height:
7.5cm
18cm
13cm
CHAPTER-4
4.1 Advantages
High torque output with a small cylinder size
Fewer moving parts
Smoother operation
Higher percentage of the time spent at top dead center (dwell) improving theoretical
engine
Lesser percentage of the time spent at bottom dead center reducing blow down time
for two stroke engines, when compared with a conventional piston and crankshaft
mechanism.
4.3 Applications
This setup is most commonly used in control valve actuators in high pressure oil and
gas pipelines
It has been used in various internal combustion engines, such as the Bourke engine,
SyTech engine, and many hot air engines and steam engines.
It is also used in multipurpose machines and I.C engines.
CHAPTER-5
CONCLUSION
The scotch yoke mechanism is made and its advantages and disadvantages are
discussed. Its motion characteristics are studied. It is concluded that this mechanism is a good
choice to convert rotating motion into reciprocating motion because of fewer moving parts
and smoother operation. It can be used in direct injection engines like diesel engines, hot air
engines.
In this project report we provide an overview of the issues concerning different
aspects of multipurpose machine using scotch yoke mechanism .The project report focus on
the principle of scotch yoke mechanism, type of tooling and machining parameters and
process performance measure, which include cutting speed, depth of cut,material removal
rate with different type of equipments which can be run simultaneously and fabricate the
work piece In multipurpose machine has been presented . the presented results can help to
plan the machining of work piece with expected tolerance.
The following major conclusions may be drawn from the present project report.
established industrial processes offering attractive capabilities for handling work piece
of various length to be used at micro level.
We have explained the various parts and components of multipurpose machine using
scotch yoke mechanism.
The vital need for the fabrication of a multipurpose machine is significant in the much
delay and time as well as energy wasted in using simple hand tools to carry out jobs.
Moreover, the cost of a lathe machine is too high for an average user. Also, multipurpose
machine will helps to reduce the cost and consequently increase the rate of production and
craftsmans skill.
The general purpose for any project is to find solutions on a certain problems. Its also
gives main idea how the project to be completed. For this project, the problems that need to
be solved are:1) Any manufacturer wants to reduce cost and time taken to complete a product but gives
better quality products and increases the outputs.
2) Manufacturer tends to upgrade their machines to compete with the new machine with
new technology.
3) Lathe machine cutting tool can easily break and needs to enhance its tool life.
The continuous quest to have the problems of man and his growing needs solved has led
to the establishment of factories and other industries, which necessitates an intermediate
technology. However, simple hand tools that were in use before are no longer efficient for
mass production. Then, there comes the need for urgent attention to better and useful
multipurpose machines.
REFERENCES
[1]
Mack. R., Mueller, R., Crotts, J., & Broderick, A. (2000). Perceptions, corrections and
[2]
[3]
[4]
[5]
[6]
[7]
Project pictures