APM-016-UL Power Supply

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

SYSTEM/MODEL: AP-M

MODIFICATION: Using UL Listed power supplies

DIFFICULTY LEVEL: 4 - Moderate/hard - Internal connection or component addition.

COMPONENTS REQUIRED: 1. PS-1820UL power supply, 18V DC

INSTR/OPERATIONS: 1. Cut wires from large AC transformer to PC board (heavy red


wires to points 27 and 28).

2. Remove incoming AC power cord from master station.

3. Reconnect the power on/off switch in series with the positive of


power supply and pt. 27 on PC-381.

4. Connect negative from the PS-1820UL power supply to GND


terminal of master station.

See following schematic.

REFERENCE DRAWING #: 0698-016, 381-016

Aiphone’s product warranty applies to products properly modified using these instructions.
However, if a unit is damaged as a result of improper modification, the warranty does not apply.
AP-M SYSTEM WITH UL LISTED POWER SUPPLIES

Disconnect AC transformer.
Cut RED wire from pt. 27,
and splice with GRAY wire
from switch.

Red wire
Gray wire

Black
+
-
X

PS-1820UL
Red

Reconnect power switch in series with "+" of power supply.


(One side of switch to Pt. 27 on PCB, other side to "+" of power supply.
Connect "-" to ground of AP-M.
AP-M Mod. #0698-016
Sch #381-016