Transmission Installation and Configurations
Transmission Installation and Configurations
Transmission Installation and Configurations
Page 1 of 29
INSTALLATION INSTRUCTIONS
Contents
1 1.1 2 2.1 2.2 2.3 2.4 3 4 4.1 4.2 4.3 4.4 5 5.1 5.2 5.3 5.4 5.5 5.6 5.7 6 Glossary Transmission Installation and Configurations RBS 6000 Indoor Introduction Target Group Prerequisites Documentation Tools Conditions Temperature Requirements Configurations Installing Transmission Cables Routing Cables in Cabinets Connecting E1 Cables to CBUs Connecting Ethernet Cables to ET-MFXs Connecting Cables to DUs Installing Transmission Configurations Installing Transmission Equipment Connecting OMS 800 Cables Connecting MINI-LINK CN 500 Family Connecting MINI-LINK CN 1000 Family Connecting MINI-LINK TN 1p Compact Node Connecting MINI-LINK TN 2p B Connecting MINI-LINK TN 6p C/D Concluding Routines
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 2 of 29
Reference List
Copyright
Ericsson AB 20092010. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner. The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document. MINI-LINK is a trademark of Telefonaktiebolaget LM Ericsson is a trademark of Ericsson Network Technologies AB
Disclaimer
Trademark List
OMS 800
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.
1 Introduction
This document describes how to install and configure transmission equipment in the indoor RBS 6000 family of RBSs.
2 Prerequisites
This section contains information on the documentation, tools, equipment, and conditions required before starting the installation and configuration procedure.
2.1 Documentation
Ensure that the following documents are available: Transmission Installation and Configurations RBS 6000 Indoor
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 3 of 29
Personal Health and Safety Information,124 46-2885 System Safety Information,124 46-2886
2.2 Tools
The table below shows the installation tools required:
Table 1 Tools
Product Name ESD wrist strap (1) T8, Torx screwdriver T30, Torx screwdriver, Screwdriver for bits 819 mm socket set with 3/8inch drive and bits Tool for cable ties 0,54 Nm torque wrench Cable ties
(1) Electrostatic Discharge (ESD)
Product Number LTT 601 136/1 LSA 901 43/6 LSA 901 43/5 LSS 103 28/1 LTT 601 138/1 LSD 901 46/1 LTT 601 145/1
Torque 6.0 Nm 2.5 Nm 0.8 Nm 2.8 Nm 1.7 Nm Transmission Installation and Configurations RBS 6000 Indoor
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 4 of 29
2.3 Conditions
Ensure the following:
The Operation and Maintenance Center (OMC) is informed that work is to start at the node site and can therefore decide what measures are necessary to minimize service disruptions Site access is granted Site Installation Documentation is available Ordered transmission equipment is available Safety information is read and understood
Transmission Equipment
OMS 800 MINI-LINK TN equipped with fan MINI-LINK TN equipped with MMU2 H and fan MINI-LINK TN 2p B Transmission Installation and Configurations RBS 6000 Indoor
-5C +45C n/a (1) -5C +55C -25C +60 C -5C +55C -25C +60 (2) C (2) -5C +50C -25C +55
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 5 of 29
equipped with NPU3 B or SXU3 B and fan MINI-LINK CN 500 family MINI-LINK CN 1000 family
(1) The unit does not operate outside the defined operating temperature area. (2) Valid for R2C and higher. Lower R-states support up to +45C with full performance and up to +50C with reduced performance. (3) R-state R1A supports up to +45C with full performance.
3 Configurations
The following transmission configurations are available:
OMS 800 MINI-LINK CN 500 Family MINI-LINK CN 1000 Family MINI-LINK TN 1p Compact Node MINI-LINK TN 2p B MINI-LINK TN 6p C/D
Unit DUG
(1)
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 6 of 29
WCDMA (CBU-based)
CBU(5) ET-MFX(6)
ET 1-4 n/a
n/a F
Digital Unit GSM (DUG). DUG can be connected through optional IP equipment. Digital Unit LTE (DUL). Digital Unit WCDMA (DUW). Control Base Unit (CBU). Exchange Terminal Multi Function Switch (ET-MFX).
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 7 of 29
Figure 1
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 8 of 29
Figure 2
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 9 of 29
Figure 3
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 10 of 29
Figure 4
RBS 6201
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 11 of 29
Figure 5
RBS 6201 V2
Key to Figures PDU TM Power Distribution Unit (PDU) Transmission Module (TM)
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 12 of 29
5.1.1
Transmission Equipment
Do!
Always use an approved ESD wrist strap when working with sensitive equipment. Damage to components mounted on printed board assemblies can occur if an ESD wrist strap is not used.
1. Put on the ESD wrist strap and connect it to an earth grounding point. 2. Unpack the equipment and check that it is all present and undamaged. 3. If necessary, attach the captive nuts to the 19-inch rails in the Transmission Module (TM) space. 4. Install the transmission equipment in the cabinet. See relevant section below. 5.1.2 OMS 800
This section describes how to install the two variants of the Optical Multiservice (OMS) 800: OMS 846 and OMS 860. To install an OMS 800, do the following: 1. Fasten the mounting brackets to the OMS 800. 2. Install the OMS 800 in the TM space, using four screws. 3. Insert a Synchronous Transport Module level 1 or level 4 (STM-1 or STM-4) Small Form-Factor Pluggable (SFP) module in the SFP module slot in the OMS 800. 4. If applicable, insert a Gigabit Ethernet (GE) SFP module. 5. Connect the cables according to Section 5.2. 5.1.3 MINI-LINK CN 500 Family Transmission Installation and Configurations RBS 6000 Indoor
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 13 of 29
This section describes how to install one variant of the MINI-LINK CN 500 family: MINI-LINK CN 500. Note: When installing transmission equipment in the TM space, leave 0.5 U spaces above and below the equipment to maintain the correct airflow.
To install a MINI-LINK CN 500, do the following: 1. Install the CN 500 in the TM space, using four screws. 2. Connect the cables according to Section 5.3. 5.1.4 MINI-LINK CN 1000 Family
This section describes how to install one variant of the MINI-LINK CN 1000 family: MINI-LINK CN 1010. To install a MINI-LINK CN 1000, do the following: 1. Fasten the mounting brackets to the MINI-LINK CN 1000. 2. Install the MINI-LINK CN 1000 in the TM space, using four screws. 3. Connect the cables according to Section 5.4. 4. If applicable, insert a Gigabit Ethernet (GE) SFP module. 5. Connect the cables according to Section 5.4. 5.1.5 MINI-LINK TN 1p Compact Node
This section describes how to install a MINI-LINK TN 1p Compact Node. Note: When installing transmission equipment in the TM space, leave 0.5 U spaces above and below the equipment to maintain the correct airflow.
To install a MINI-LINK TN 1p Compact Node, do the following: Transmission Installation and Configurations RBS 6000 Indoor
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 14 of 29
1. Fasten the mounting brackets to the node and snap them into place. 2. Install the compact node in the TM space, using four screws. 3. Connect the cables according to Section 5.5. 5.1.6 MINI-LINK TN 2p B
This section describes how to install a MINI-LINK TN 2p B. To install a MINI-LINK TN 2p B do the following: 1. Remove the cover on top of an Access Module Magazine (AMM). 2. Insert a fan unit board FAU4 on top of the AMM and fasten it. 3. Install the AMM in the TM space, using four screws. 4. Insert an Removable Memory Module (RMM) inside the Node Processor Unit (NPU) according to the instructions in document RMM Handling Instructions, Reference [6]. 5. Insert NPU3 or NPU3 B board in the upper-left position in the AMM. 6. Insert Line Terminal Unit (LTU) board LTU3 or a dummy board in the lower-left position in the AMM. 7. Insert one or two MMU boards, depending on the configuration, or dummy MMU boards in the upper-right or lower-right position in the AMM. 8. Connect the cables according to Section 5.6. 5.1.7 MINI-LINK TN 6p C/D
This section describes how to install a MINI-LINK TN 6p C/D. To install a MINI-LINK TN 6p C/D do the following: 1. Install an AMM in the TM space, using four screws. 2. Insert Power Unit (PFU) PFU3 B in the upper-left position in the AMM. 3. Insert PFU3 B or a dummy PFU3 B in the lower-left position in the AMM. Transmission Installation and Configurations RBS 6000 Indoor
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 15 of 29
4. Insert an RMM inside the NPU unit according to the instructions in document RMM Handling Instructions, Reference [6]. 5. Insert an NPU3 or NPU3 B in the upper-right position in the AMM. 6. Insert an LTU3 or a dummy board in the upper-left position in the AMM. 7. Insert one to five MMU boards, depending on the configuration, or dummy MMU/LTU boards, in the AMM. If Cross Polarization Interface Canceller (XPIC) configuration is used, then start from the lower-right position (slot 2). Place pairs of MMUs with XPIC support in adjacent slots (slot 2 and slot 3 or slot 4 and slot 5) as the slots are related to the same polarization. The front panels XPIC cross-cable connection connects MMUs in alternate slots (slot 2 and slot 4 or slot 3 and slot 5). For more information see Installing Indoor Equipment, MINI-LINK TN ETSI, Reference [8]. 8. Insert a fan unit board FAU2 between the PFU3 B and the MMU. 9. Connect the cables according to Section 5.7.
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 16 of 29
Figure 6
Table 5
Pos. 1 2 3 4A 4B
Product No.(1) Unit RPM 919 721/L TSR 391 3079/L TSR 391 3043/L RPM 777 15/L TSR 432 151/L OMS 800 OMS 800 OMS 800 OMS 800 OMS 800
Connection -48 V DC LC connector SC connector F Ethernet port Ethernet port Ethernet port ET 12
or GE
(5)
(6)(7)
FE or GE TRIB 1
6A
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 17 of 29
TRIB 3 TRIB 4 TRIB 1 TRIB 2 TRIB 3 TRIB 4 TRIB 5 [and so on] TRIB 16
ET 34 ET A ET B RBS RBS RBS RBS RBS RBS RBS RBS 3202, 3206, 3216, 2216 6201, 6201 V2, 2206 V2, 2216 V2
OMS 800
(6)
OMS 800
RBS E1 drops
L = defined length of cable. SFP Module (STM-1 or STM-4). Optical Distribution Frame (ODF). Fast Ethernet (FE). SFP Module (GE). Optional connection. Used only if internal Ethernet cable is not used.
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 18 of 29
Figure 7
Table 6
Pos. 1
(2)
Product No.(1) Unit RPM 919 715/L RPM 919 403/L RPM 919 607/L RPM 777 15/L TSR 432 151/L Power supply CN 500 CN 500 CN 500 CN 500
From Connection -48VDC TR:5A-5D TR:5A-5D GE GE PDU CBU DU ET-MFX Optional IP equipment DU
(3)
To Unit Connection -48 V DC ET 1-2 ET 3-4 ET A ET B F Ethernet port Ethernet port Ethernet port RBS 3202, RBS 3206,
2A 2B 3A 3B
(3) (3)
GE TR:4A-4D TR:3A-3D
5A
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 19 of 29
TR:2A-2D 5B
(3)
RBS 3216, RBS 2216 RBS E1 drops RBS RBS RBS RBS 6201, 6201 V2, 2206 V2, 2216 V2
CN 500
CN 500
Antenna
Jumper Cable
(1) L = defined length of cable. (2) 12 power cables allowed. (3) Optional connection.
Figure 8
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 20 of 29
Pos. 1 2 3 4 5A
(2)
Product No.(1) Unit RPM 919 715/L TSR 432 151/L RPM 919 701/L TSR 432 151/L TSR 482 0244/L Power supply CN 1000 CN 1000 Ethernet port CN 1000
From Connection -48VDC GE TR:1A-1B TR:2A-2B GE TR:1A-1B TR:2A-2B TR:3A-1B TR:4A-2B TR:1A-1B TR:2A-2B TR:3A-1B TR:4A-2B OMS OMS TR:1A-1B TR:2A-2B GE PDU DU DU RBS Ethernet drops RBS E1 drops Unit
5B
CN 1000
RBS E1 drops
RBS 2206 RBS 2216 RBS 6201 RBS 6201 based) LC SC TR:5A-5B GE
V2 V2 (GSM-based) V2 (GSM-
6A 6B 7 8
TSR 391 3079/L TSR 391 3043/L RPM 919 607/L TSR 432 151/L
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 21 of 29
Figure 9
Table 8
Pos. 1 2A 2B 3A
(3)
Product No.(1) Unit RPM 919 715/L RPM 919 403/L RPM 919 607/L RPM 919 606/L Power supply MMU MMU MMU
ET A ET B RBS RBS RBS RBS RBS RBS RBS RBS 3202, 3206, 3216, 2216 6201, 6201 V2, 2206 V2, 2216 V2
3B
(3)
MMU
RBS E1 drops
Jumper Cable
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 22 of 29
(1) L = defined length of cable. (2) Letters in parentheses refer to cable-end markings. (3) Optional connection.
Figure 10
Table 9
MINI-LINK TN 2p B
Pos. 1(2) 2A
Product No. (1) Unit RPM 919 715/L RPM 919 403/L Power supply
To Connection -48 V DC ET 12
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 23 of 29
ET 34 2B 3A 3B RPM 919 607/L RPM 777 15/L TSR 432 151/L NPU3/NPU3 B NPU3/NPU3 B NPU3/NPU3 B E1:4A4D FE/GE FE/GE
(4) (4) (3)
ET A ET B F Ethernet port Ethernet port Ethernet port RBS RBS RBS RBS RBS RBS RBS RBS RBS RBS RBS RBS RBS RBS RBS RBS 3202, 3206, 3216, 2216 3202, 3206, 3216, 2216 6201, 6201 V2, 2206 V2, 2216 V2 6201, 6201 V2, 2206 V2, 2216 V2
NPU3/NPU3 B LTU3
FE/GE
(4)
5A
5B
(7)(5)
NPU3/NPU3 B
E1:4A4D
RBS E1 drops
6A
(5)
LTU3
RBS E1 drops
6B
(5)(7)
NPU3/NPU3 B
E1:4A4D
RBS E1 drops
7
(1) (2) (3) (4) (5) (6) (7)
MMU
RAU
Antenna
Jumper cable
L = defined length of cable. 12 power cables allowed. Letters in parentheses refer to cable-end markings. NPU3 in FE configurations supports one Ethernet port. Optional connection. NPU3 B in FE/GE configurations support up to two Ethernet ports; one for Ethernet and one for DCN or Ethernet. Not shown in figure.
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 24 of 29
Figure 11
Table 10
MINI-LINK TN 6p C/D
MINI-LINK TN 6p C/D Cable Connections
Pos.
Product No.(1)
To
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 25 of 29
Unit 1
(2)
Connection -48 V DC ET 12 ET 34 ET A ET B F Ethernet port Ethernet port Ethernet port RBS RBS RBS RBS RBS RBS RBS RBS RBS RBS RBS RBS RBS RBS RBS RBS 3202, 3206, 3216, 2216 3202, 3206, 3216, 2216 6201, 6201 V2, 2206 V2, 2216 V2 6201, 6201 V2, 2206 V2, 2216 V2
RPM 919 714/L RPM 919 403/L RPM 919 607/L RPM 777 15/L TSR 432 151/L
2A 2B 3A 3B
NPU3/NPU3 B LTU3
FE/GE
(3)
5A
5B
(6)
(4)
NPU3/NPU3 B
E1:4A4D
RBS E1 drops
6A
(4)
LTU3
RBS E1 drops
6B
(6)
(4)
NPU3/NPU3 B
E1:4A4D
RBS E1 drops
7
(1) (2) (3) (4) (5) (6)
MMU
RAU
Antenna
Jumper cable
L = length of cable. 12 power cables allowed. NPU3 in FE configurations supports one Ethernet port. Optional connection. NPU3 B in FE/GE configurations supports up to two Ethernet ports; one for Ethernet and one for DCN or Ethernet. Not shown in figure.
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 26 of 29
6 Concluding Routines
Before leaving the site, do the following:
Clean the site and remove objects such as wrapping paper and pieces of cable Dispose of waste in accordance with local regulations Report any faults in accordance with local requirements Collect all tools Close and lock the cabinet Inform the OMC that work is finished at the node site Complete the work order
Glossary
AMM Access Module Magazine CBU Control Base Unit CN Compact Node CPI Customer Product Information DU Digital Unit DUG Transmission Installation and Configurations RBS 6000 Indoor
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 27 of 29
Digital Unit GSM DUL Digital Unit LTE DUW Digital Unit WCDMA ESD Electrostatic Discharge ET-MFX Exchange Terminal Multi Function Switch FE Fast Ethernet GE Gigabit Ethernet IP Internet Protocol LAN Local Area Network LTU Line Terminal Unit n/a Not Applicable NPU Node Processor Unit Transmission Installation and Configurations ODF
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 28 of 29
Optical Distribution Frame OMC Operation and Maintenance Center OMS Optical Multiservice PDU Power Distribution Unit PFU Power Unit RMM Removable Memory Module SFP Small Form-Factor Pluggable SIU Site Integration Unit STM Synchronous Transport Module TM Transmission Module TN Traffic Node
Reference List
Transmission Installation and Configurations RBS 6000 Indoor
http://cpistore.internal.ericsson.com/alexserv?ID=10835&DB=28965-lzn7601006r6a.alx&FN=3_1531-LZA7016009Uen.D.html
10/06/2011
Page 29 of 29
Safety Documentation
[1] Personal Health and Safety Information, 124 46-2885 [2] System Safety Information, 124 46-2886
RBS
[3] Hardware Maintenance Instructions, for the applicable RBS [4] RBS Configurations, for the applicable RBS [5] Installing RBS, for the applicable RBS
Site
[6] RMM Handling Instructions, included with the RMM, 1424-EN/LZT 712 0244 [7] Site Installation Documentation (specific for the site)