Troubleshooting Routers Cisco
Troubleshooting Routers Cisco
Troubleshooting Routers Cisco
Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS. THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY. The following information is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense. The following information is for FCC compliance of Class B devices: The equipment described in this manual generates and may radiate radio-frequency energy. If it is not installed in accordance with Ciscos installation instructions, it may cause interference with radio and television reception. This equipment has been tested and found to comply with the limits for a Class B digital device in accordance with the specifications in part 15 of the FCC rules. These specifications are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. Modifying the equipment without Ciscos written authorization may result in the equipment no longer complying with FCC requirements for Class A or Class B digital devices. In that event, your right to use the equipment may be limited by FCC regulations, and you may be required to correct any interference to radio or television communications at your own expense. You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Cisco equipment or one of its peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by using one or more of the following measures: Turn the television or radio antenna until the interference stops. Move the equipment to one side or the other of the television or radio. Move the equipment farther away from the television or radio. Plug the equipment into an outlet that is on a different circuit from the television or radio. (That is, make certain the equipment and the television or radio are on circuits controlled by different circuit breakers or fuses.) Modifications to this product not authorized by Cisco Systems, Inc. could void the FCC approval and negate your authority to operate the product. The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCBs public domain version of the UNIX operating system. All rights reserved. Copyright 1981, Regents of the University of California. NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED AS IS WITH ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE. IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Cisco and the Cisco Logo are trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and other countries. A listing of Cisco's trademarks can be found at www.cisco.com/go/trademarks. Third party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1005R) Cisco 1800 Series Integrated Services Routers (Fixed) Hardware Installation Guide Copyright 2005-2008 Cisco Systems, Inc. All rights reserved.
Contents
CHAPTER
Introduction to Cisco 1800 Series Routers (Modular) Hardware Documentation Objectives Audience Conventions Organization
1-5 1-6 1-6 1-7 1-7 1-13 1-14
1-5
Safety Warnings
Related Documentation
Cisco One-Year Limited Hardware Warranty Terms Searching for Cisco Documents
1-15
1-15
CHAPTER
2-1
Hardware Features 2-2 Product Serial Number Location 2-3 Cisco Product Identification Tool 2-3 Interfaces 2-3 Interfaces on the Cisco 1841 Router 2-4 Interfaces on the Cisco 1861 Integrated Services Router Removable and Interchangeable Modules 2-5 Memory 2-5 LED Indicators 2-6 Chassis Ventilation 2-7 Real-Time Clock 2-7 Chassis Security 2-8 Chassis Views
2-8 2-9 2-10
2-4
CHAPTER
Preinstallation Requirements and Planning for Cisco 1800 Series Routers (Modular) Safety Recommendations 3-1 Safety with Electricity 3-2 Preventing Electrostatic Discharge Damage General Site Requirements 3-3 Power Supply Considerations Site Environment 3-4
3-3
3-1
3-3
Contents
3-4 3-4
Inspecting the Router 3-6 Items in the Box for the Cisco 1841 Router 3-6 Items in the Box for the Cisco 1861 Integrated Services Router 3-6 Items not Included in the Box for the Cisco 1861 Integrated Services Router Required Tools and Equipment for Installation and Maintenance
4
3-7
3-7
CHAPTER
Chassis Installation Procedures for Cisco 1800 Series Routers (Modular) Setting Up the Chassis 4-3 Setting the Chassis on a Desktop 4-3 Rack-Mounting a Cisco 1800 Series Modular-Configuration Router Attaching Rack-Mount Brackets 4-4 Installing the Router in a Rack 4-5 Chassis Grounding 4-6 Wall-Mounting the Chassis 4-6 Wall-Mounting the Cisco 1841 Router 4-6 Wall-Mounting the Cisco 1861 Integrated Services Router 4-8 Rack-Mounting the Cisco 1861 Integrated Services Router 4-9
4-1
4-3
Installing the Chassis Ground Connection 4-11 Installing the Chassis Ground Connection on the Cisco 1841 Router 4-11 Installing the Chassis Ground Connection on the Cisco 1861 Integrated Services Router
5
4-12
CHAPTER
Cable Information and Specifications for Cisco 1800 Series Routers (Modular) Console and Auxiliary Port Considerations Console Port Connections 5-1 Auxiliary Port Connections 5-2
5-1
5-1
Preparing to Connect to a Network 5-2 Ethernet Connections 5-2 Serial Connections 5-3 Configuring Serial Connections 5-3 Serial DTE or DCE Devices 5-3 Signaling Standards Supported 5-3 Distance Limitations 5-4 Asynchronous/Synchronous Serial Module Baud Rates ISDN BRI Connections 5-5 CSU/DSU Connections 5-5
5-4
OL-5876-03
Contents
CHAPTER
Cable Connection Procedures for Cisco 1800 Series Routers (Modular) Power Connections
6-1
6-1
Connecting WAN and LAN Cables 6-2 Ports and Cabling 6-2 Connection Procedures and Precautions
6-3
Connecting to a Console Terminal or Modem 6-3 Connecting to the Console Port 6-4 Connecting to the Auxiliary Port 6-4 Connecting Power to the Cisco 1861 Integrated Services Router
7
6-5
CHAPTER
Power-Up Procedures for Cisco 1800 Series Routers (Modular) Powering Up Cisco 1800 Series Routers Checklist for Power Up 7-2 LED Indicators 7-2 Power-Up Procedure 7-2
7-1
7-1
Verifying the LED Indicators on the 1841 Router Verifying the Hardware Configuration
7-5
7-4 7-4
Verifying the LED Indicators on the 1861 Integrated Services Router Initial Configuration of the Router 7-5 Initial Configuration 7-5 Cisco Router and Security Device Manager Verifying the Initial Configuration 7-6 Completing the Configuration 7-6
7-6
7-7 7-7
CHAPTER
8-1
Problem Solving 8-1 Troubleshooting the Power and Cooling Systems 8-2 Normal Indications 8-2 Fault Indications 8-2 Environmental Reporting Features 8-3 Troubleshooting Cables, Connections, and Interface Cards Reading LEDs
8-4 8-5 8-6 8-6
8-3
System Messages
Contents
CHAPTER
Installing Interface Cards in Cisco 1800 Series Routers (Modular) Cisco Interface Cards Installation Guide Related Product Documentation
9-1 9-1 9-1
9-1
CHAPTER
Installing and Replacing CompactFlash Memory Cards on Cisco 1800 Series Routers (Modular) 10-1 Preventing Electrostatic Discharge Damage 10-1 Replacing CompactFlash Memory Cards 10-1 Removing a CompactFlash Memory Card 10-2 Installing a CompactFlash Memory Card 10-2 Using the Compact Flash Guard 10-2 Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular) Safety Warnings
11-1 11-2 11-1
CHAPTER
11
Modules Internal to the Cisco 1841 Router Opening the Chassis 11-2 Locating Modules 11-4 Installing a SODIMM 11-5 Installing an AIM 11-6 Accessory Kit to Use 11-7 Installation Procedure 11-7 Applying the AIM Label 11-11 Closing the Chassis 11-11
OL-5876-03
CH A P T E R
Objectives, page 1-5 Audience, page 1-6 Organization, page 1-6 Conventions, page 1-7 Safety Warnings, page 1-7 Related Documentation, page 1-13 Cisco One-Year Limited Hardware Warranty Terms, page 1-14 Searching for Cisco Documents, page 1-15 Obtaining Documentation and Submitting a Service Request, page 1-15
Objectives
This documentation explains how to install, maintain, and troubleshoot your router hardware. Although this documentation provides minimum software configuration information, it is not comprehensive. For detailed software configuration information, see Cisco 1800 series software configuration documentation and the Cisco IOS configuration guide and command reference publications. These publications are available online. See the Obtaining Documentation and Submitting a Service Request section on page 1-15 for more information. This documentation describes the Cisco 1800 series (modular), currently consisting of the Cisco 1841 router and the Cisco 1861 integrated services router (ISR).
Note
With the exception of when the Cisco 1861 ISR is specifically mentioned, all information in this document describes the Cisco 1841 router. To access the warranty, service, and support information, see the Cisco One-Year Limited Hardware Warranty Terms section on page 1-14.
1-5
Chapter 1 Audience
Audience
This documentation is designed for the person installing, configuring, and maintaining the router, who should be familiar with electronic circuitry and wiring practices and has experience as an electronic or electromechanical technician. The documentation identifies those procedures that should be performed only by trained and qualified personnel.
Organization
Table 1-1 lists the topics covered by these hardware documents.
Table 1-1 Document Organization
Title Overview of Cisco 1800 Series Routers (Modular) Preinstallation Requirements and Planning for Cisco 1800 Series Routers (Modular)
Description Describes the features and specifications of the Cisco 1841 router and the Cisco 1861 ISR. Describes safety recommendations, site requirements, required tools and equipment, and includes an installation checklist.
Cable Information and Specifications for Provides information about cables needed to install your Cisco 1841 router and Cisco 1800 Series Routers (Modular) Cisco 1861 ISR. Chassis Installation Procedures for Cisco Describes how to install your Cisco 1841 router on a desktop and how to mount your 1800 Series Routers (Modular) Cisco 1861 ISR on a wall or in a rack. Cable Connection Procedures for Cisco 1800 Series Routers (Modular) Power-Up Procedures for Cisco 1800 Series Routers (Modular) Describes how to connect your Cisco 1841 router and your Cisco 1861 ISR to a power source and to networks and external devices. Describes how to power up your Cisco 1841 router and your Cisco 1861 ISR and perform an initial configuration to provide network access. Describes how to isolate problems, read LEDs, and interpret messages. Describes the procedures for installing the various types of interface cards in external chassis slots. Describes how to install or upgrade modules that are located within the router, such as memory modules and AIMs. Describes hardware installation procedures for the external CompactFlash memory card.
Troubleshooting Cisco 1800 Series Routers (Modular) Installing Interface Cards in Cisco 1800 Series Routers (Modular) Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular) Installing and Replacing CompactFlash Memory Cards on Cisco 1800 Series Routers (Modular)
1-6
OL-5876-03
Chapter 1
Conventions
This documentation uses the conventions listed in Table 1-2 to convey instructions and information.
Table 1-2 Document Conventions
Description Commands and keywords. Variables for which you supply values. Optional keywords or arguments appear in square brackets. A choice of required keywords appears in braces separated by vertical bars. You must select one. Examples of information displayed on the screen. Examples of information you must enter. Nonprinting characters, for example passwords, appear in angle brackets in contexts where italics are not available. Default responses to system prompts appear in square brackets.
< [
> ]
Note
Means reader take note. Notes contain helpful suggestions or references to material not covered in the manual.
Timesaver
Means the described action saves time. You can save time by performing the action described in the paragraph.
Tip
Means the following information will help you solve a problem. The tips information might not be troubleshooting or even an action, but could be useful information, similar to a Timesaver.
Caution
Means reader be careful. In this situation, you might do something that could result in equipment damage or loss of data.
Safety Warnings
Safety warnings appear throughout this publication in procedures that, if performed incorrectly, may harm you. A warning symbol precedes each warning statement. To see translations of the warnings that appear in this publication, see Regulatory Compliance and Safety Information for Cisco 1840 Routers.
1-7
Note
The title Regulatory Compliance and Safety Information for Cisco 1840 Routers refers to a specific chassis model: the Cisco 1840. The Cisco 1841 router received compliance certification under the chassis model Cisco 1840. The same regulatory compliance and safety information for the Cisco 1841 router is applicable to the Cisco 1861 ISR.
Warning
IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071 SAVE THESE INSTRUCTIONS
Waarschuwing
BELANGRIJKE VEILIGHEIDSINSTRUCTIES Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van de standaard praktijken om ongelukken te voorkomen. Gebruik het nummer van de verklaring onderaan de waarschuwing als u een vertaling van de waarschuwing die bij het apparaat wordt geleverd, wilt raadplegen. BEWAAR DEZE INSTRUCTIES
Varoitus
TRKEIT TURVALLISUUSOHJEITA Tm varoitusmerkki merkitsee vaaraa. Tilanne voi aiheuttaa ruumiillisia vammoja. Ennen kuin ksittelet laitteistoa, huomioi shkpiirien ksittelemiseen liittyvt riskit ja tutustu onnettomuuksien yleisiin ehkisytapoihin. Turvallisuusvaroitusten knnkset lytyvt laitteen mukana toimitettujen knnettyjen turvallisuusvaroitusten joukosta varoitusten lopussa nkyvien lausuntonumeroiden avulla. SILYT NM OHJEET
Attention
IMPORTANTES INFORMATIONS DE SCURIT Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant entraner des blessures ou des dommages corporels. Avant de travailler sur un quipement, soyez conscient des dangers lis aux circuits lectriques et familiarisez-vous avec les procdures couramment utilises pour viter les accidents. Pour prendre connaissance des traductions des avertissements figurant dans les consignes de scurit traduites qui accompagnent cet appareil, rfrez-vous au numro de l'instruction situ la fin de chaque avertissement. CONSERVEZ CES INFORMATIONS
1-8
OL-5876-03
Chapter 1
Introduction to Cisco 1800 Series Routers (Modular) Hardware Documentation Safety Warnings
Warnung
WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen fhren kann. Machen Sie sich vor der Arbeit mit Gerten mit den Gefahren elektrischer Schaltungen und den blichen Verfahren zur Vorbeugung vor Unfllen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen bersetzung in den bersetzten Sicherheitshinweisen, die zusammen mit diesem Gert ausgeliefert wurden. BEWAHREN SIE DIESE HINWEISE GUT AUF.
Avvertenza
IMPORTANTI ISTRUZIONI SULLA SICUREZZA Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di intervenire su qualsiasi apparecchiatura, occorre essere al corrente dei pericoli relativi ai circuiti elettrici e conoscere le procedure standard per la prevenzione di incidenti. Utilizzare il numero di istruzione presente alla fine di ciascuna avvertenza per individuare le traduzioni delle avvertenze riportate in questo documento. CONSERVARE QUESTE ISTRUZIONI
Advarsel
VIKTIGE SIKKERHETSINSTRUKSJONER Dette advarselssymbolet betyr fare. Du er i en situasjon som kan fre til skade p person. Fr du begynner arbeide med noe av utstyret, m du vre oppmerksom p farene forbundet med elektriske kretser, og kjenne til standardprosedyrer for forhindre ulykker. Bruk nummeret i slutten av hver advarsel for finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne enheten. TA VARE P DISSE INSTRUKSJONENE
Aviso
INSTRUES IMPORTANTES DE SEGURANA Este smbolo de aviso significa perigo. Voc est em uma situao que poder ser causadora de leses corporais. Antes de iniciar a utilizao de qualquer equipamento, tenha conhecimento dos perigos envolvidos no manuseio de circuitos eltricos e familiarize-se com as prticas habituais de preveno de acidentes. Utilize o nmero da instruo fornecido ao final de cada aviso para localizar sua traduo nos avisos de segurana traduzidos que acompanham este dispositivo. GUARDE ESTAS INSTRUES
Advertencia!
INSTRUCCIONES IMPORTANTES DE SEGURIDAD Este smbolo de aviso indica peligro. Existe riesgo para su integridad fsica. Antes de manipular cualquier equipo, considere los riesgos de la corriente elctrica y familiarcese con los procedimientos estndar de prevencin de accidentes. Al final de cada advertencia encontrar el nmero que le ayudar a encontrar el texto traducido en el apartado de traducciones que acompaa a este dispositivo. GUARDE ESTAS INSTRUCCIONES
1-9
Varning!
VIKTIGA SKERHETSANVISNINGAR Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utfr arbete p ngon utrustning mste du vara medveten om farorna med elkretsar och knna till vanliga frfaranden fr att frebygga olyckor. Anvnd det nummer som finns i slutet av varje varning fr att hitta dess versttning i de versatta skerhetsvarningar som medfljer denna anordning. SPARA DESSA ANVISNINGAR
1-10
OL-5876-03
Chapter 1
Introduction to Cisco 1800 Series Routers (Modular) Hardware Documentation Safety Warnings
Aviso
INSTRUES IMPORTANTES DE SEGURANA Este smbolo de aviso significa perigo. Voc se encontra em uma situao em que h risco de leses corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os circuitos eltricos e familiarize-se com as prticas padro de preveno de acidentes. Use o nmero da declarao fornecido ao final de cada aviso para localizar sua traduo nos avisos de segurana traduzidos que acompanham o dispositivo. GUARDE ESTAS INSTRUES
Advarsel
VIGTIGE SIKKERHEDSANVISNINGER Dette advarselssymbol betyder fare. Du befinder dig i en situation med risiko for legemesbeskadigelse. Fr du begynder arbejde p udstyr, skal du vre opmrksom p de involverede risici, der er ved elektriske kredslb, og du skal stte dig ind i standardprocedurer til undgelse af ulykker. Brug erklringsnummeret efter hver advarsel for at finde oversttelsen i de oversatte advarsler, der fulgte med denne enhed. GEM DISSE ANVISNINGER
1-11
1-12
OL-5876-03
Chapter 1
Introduction to Cisco 1800 Series Routers (Modular) Hardware Documentation Related Documentation
Related Documentation
The Cisco IOS software that runs your Cisco 1800 series router includes extensive features and functionality. For information that is beyond the scope of this document, or for additional information, see Table 1-3.
Timesaver
Make sure that you have access to the documents listed in Table 1-3. Some of these documents are available in print, and all are available on Cisco.com. To order printed documents, see the Obtaining Documentation and Submitting a Service Request section on page 1-15.
1-13
Table 1-3
Document Title Cisco 1800 Series Integrated Services Routers (Modular) Quick Start Guide Cisco 1800 Series Software Configuration Cisco Network Modules and Interface Cards Regulatory Compliance and Safety Information Regulatory Compliance and Safety Information for Cisco 1840 Routers Cisco Modular Access Router Cable Specifications Overview of Cisco Interface Cards for Cisco Access Routers Quick Start Guide for the Cisco 1861 Integrated Services Router
Cisco IOS software documentation, all releases. See the documentation for the Cisco IOS software release installed on your router.
Launch your browser, and go to this URL: http://www.cisco.com/univercd/cc/td/doc/es_inpck/cetrans.htm The Warranties and License Agreements page appears.
2.
and US FCC Notice link. The Cisco Limited Warranty and Software License page from the Information Packet appears.
b. Read the document online, or click the PDF icon to download and print the document in Adobe
Note
You must have Adobe Acrobat Reader to view and print PDF files. You can download the reader from Adobes website: http://www.adobe.com
You can also contact the Cisco service and support website for assistance: http://www.cisco.com/public/Support_root.shtml.
Duration of Hardware Warranty
1-14
OL-5876-03
Chapter 1
Introduction to Cisco 1800 Series Routers (Modular) Hardware Documentation Searching for Cisco Documents
Cisco or its service center will use commercially reasonable efforts to ship a replacement part within ten (10) working days after receipt of a Return Materials Authorization (RMA) request. Actual delivery times can vary, depending on the customer location. Cisco reserves the right to refund the purchase price as its exclusive warranty remedy.
To Receive a Return Materials Authorization (RMA) Number
Contact the company from whom you purchased the product. If you purchased the product directly from Cisco, contact your Cisco Sales and Service Representative. Complete the following information, and keep it for reference. Company product purchased from Company telephone number Product model number Product serial number Maintenance contract number
1-15
1-16
OL-5876-03
CH A P T E R
SYS PWR
SYS ACT
Cisco 18
00
Series
The Cisco 1861 ISR, which is part of the Cisco 1800 series ISR family, is a unified communications solution for small- to medium-sized businesses and enterprise small branch offices that provides voice, data, voice-mail, automated attendant, video, and security capabilities while integrating with existing desktop applications such as calendar, e-mail, and customer relationship management (CRM) programs and with built-in security. It has the following core components:
Integrated Cisco Unified Communications Manager Express or Survivable Remote Site Telephony for call processing for up to 12 users Optional Cisco Unity Express for voice messaging and automated attendant Integrated LAN switching with Power over Ethernet (POE) expandable via Cisco Catalyst Switches Optional support for a range of WAN interface cards
Figure 2-2 and Figure 2-3 show the Cisco 1861 ISR.
2-1
122331
Figure 2-2
SYS POE VM
Cisco 18 00
Series
2 3
1 2
Figure 2-3
1
SYS POE VM
1
Cisco 18 00
00
Series
2 3 4
1 2
3 4
This chapter describes the features and specifications of the router and includes the following sections:
Hardware Features, page 2-2 Chassis Views, page 2-8 Interface Numbering, page 2-9 Interface Numbering on the 1861 Integrated Services Router, page 2-10 Specifications, page 2-11 Regulatory Compliance, page 2-11
Hardware Features
This section describes the basic features of Cisco 1800 series routers. It contains the following:
2-2
OL-5876-03
231625
231626
Chapter 2
Interfaces, page 2-3 Removable and Interchangeable Modules, page 2-5 Memory, page 2-5 LED Indicators, page 2-6 Chassis Ventilation, page 2-7 Real-Time Clock, page 2-7 Chassis Security, page 2-8
CISCO
1841
100-240 VAC1A 50/60 Hz
SN: AAANNNNXXXX
Search option allows browsing for models using a tree-structured product hierarchy. Search field on the final results page makes it easier to look up multiple products. End-of-sale products are clearly identified in results lists.
The tool streamlines the process of locating serial number labels and identifying products. Serial number information expedites the entitlement process and is important for access to support services. The Cisco Product Identification tool can be accessed at the following URL: http://tools.cisco.com/Support/CPI/index.do
Interfaces
This section summarizes the interfaces available on the Cisco 1800 series routers.
122334
2-3
Two Fast Ethernet ports (RJ-45 connectors) High-speed console and auxiliary ports, up to 115.2 kbps each (RJ-45 connectors) One USB port (version 1.1), intended for future use
Note
In Table 2-1, all slots/ports are numbered right to left, unless otherwise noted.
Table 2-1 Cisco 1861 Integrated Services Router: Interfaces
Description Console/Aux port Fast Ethernet 10/100 expansion port Fast Ethernet 10/100 WAN port
Value in Software Configuration FastEthernet0/1/8 FastEthernet0/0 FastEthernet0/1/0 to 0/1/7 port 0/0/0 to 0/0/3 port 0/1/0 to 0/1/3 Top-to-bottom, port 0/1/0 to 0/1/1 Vlan1 Vlan100 voice-port 0/4/0
Fast Ethernet 10/100 Power over Power over Ethernet, and Ethernet (PoE) ports ACT 0 LNK to ACT 7 LNK FXS (Foreign Exchange Station) FXS, and ports 0-3 FXO (Foreign Exchange Office) ports ISDN BRI ports VLAN number for data network Music-on-Hold (MoH) port Compact Flash slot (Factory Option) VIC: BRI* COMPACT FLASH VIC2-2BRI-NT/TE and 0-1 FXO, and 0-3 B0 - B1
2-4
OL-5876-03
Chapter 2
Table 2-1
Value in Software Configuration port 0/2/0 to 0/2/1 or port 0/2/0 to 0/2/3 port 0/2/0 to 0/2/1 or port 0/2/0 to 0/2/3
* Only one optional VIC can be factory installed in a Cisco 1861 Integrated Services Router.
Flash memory and interface cards fit into slots on the chassis and can be installed or removed without opening the chassis. There are three types of interface cards for the 1800 series modular routers:
WAN interface cards (WICs) Voice WAN interface cards (VWICsin data mode only on the Cisco 1841) High-speed WAN interface cards (HWICs)
The following components plug into connectors inside the chassis and can be installed or removed only by opening the chassis:
Advanced integration module (AIM) Synchronous dynamic RAM (SDRAM) small-outline dual in-line memory module (SODIMM)
CompactFlash Memory 1
Interface Cards
AIMs
SDRAM SODIMM 1
2 single-wide cards 1
Memory
Cisco 1800 series routers contain the following types of memory:
SDRAMServes two functions. It stores the running configuration and routing tables, and it is used for packet buffering by the network interfaces. Cisco IOS software executes from SDRAM. Flash memoryStores the operating system software image, configuration files, and log files. It is implemented in an external CompactFlash memory card.
2-5
Boot/NVRAMServes two functions. It stores the ROM monitor, which allows you to boot an operating system software image from flash memory. It also stores the system configuration file and the virtual configuration register.
Table 2-3 lists the memory specifications for Cisco 1800 series routers.
Table 2-3 Router Memory Specifications for the Cisco 1841 Router
Specification 128 MB, expandable to 384 MB; default is 128 MB 32, 64, or 128 MB; default is 32MB 2/4 MB flash memory
Note
SDRAM and the flash memory are user-upgradable, but the boot/NVRAM is permanently soldered to the routers motherboard and is not upgradable.
Table 2-4 Router Memory Specifications for the Cisco 1861 ISR
LED Indicators
Table 2-5 summarizes the LED indicators for the Cisco 1841 router that are located in the router bezel or chassis, but not in the interface cards. For descriptions of the LEDs in the interface cards, see Cisco Interface Card Installation Guide.
Table 2-5 Summary of Cisco 1800 Series LED Indicators
LED SYS PWR SYS ACT CF FDX (FE 0/0) 100 (FE 0/0) Link (FE 0/0) FDX (FE 0/1)
Description Router has successfully booted and the software is functional. This LED blinks while booting or in the ROM monitor. Blinking when any packets are transmitted or received on any WAN or LAN, or when monitoring system activity.
On when flash memory is busy. Do not remove the CompactFlash Back memory card when this light is on. On indicates full-duplex operation. Off indicates half-duplex operation. On indicates a 100-Mbps link. Off indicates a 10-Mbps link. On when the router is correctly connected to a local Ethernet LAN through Ethernet port 0. On indicates full-duplex operation. Off indicates half-duplex operation. Back Back Back Back
2-6
OL-5876-03
Chapter 2
Table 2-5
Description On indicates a 100-Mbps link. Off indicates a 10-Mbps link. On when the router is correctly connected to a local Ethernet LAN through Ethernet port 1. On indicates presence of an AIM in the internal AIM slot.
Figure 2-5 summarizes the LED indicators for the Cisco 1861 ISR that are located in the router bezel.
Figure 2-5 LEDs on the Front Panel of the Cisco 1861 Integrated Services Router
4 3 2 1
1 2 3 4
230870
Chassis Ventilation
An internal three-speed fan provides chassis cooling. An onboard temperature sensor controls the fan speed. The fan is always on when power is applied to the router. Under most conditions, the fan operates at the slowest speed to conserve power and reduce fan noise. It operates at the higher speeds when necessary under conditions of higher ambient temperature.
Real-Time Clock
An internal real-time clock with battery backup provides the system software with time of day on system power up. This allows the system to verify the validity of a certification authority (CA) certificate. The backup battery is a socketed lithium battery. This battery lasts the life of the router under the operating environmental conditions specified for the router, and is not field replaceable.
2-7
Note
If the lithium battery in a Cisco 1841 router should fail, the router must be returned to Cisco for repair. Do not replace the battery yourself. Although the battery is not intended to be field replaceable, the safety agencies require the following warning be included in this document.
Warning
There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturers instructions. Statement 1015
Chassis Security
The chassis of the Cisco 1841 router is constructed with a KensingtonTM security slot on the back panel. It can be secured to a desktop or other surface by using KensingtonTM lockdown equipment.
Chassis Views
This section contains views of the front and rear panels of Cisco 1841 router, showing the locations of the power and signal interfaces, the interface card slots, and the status indicators. Figure 2-6 shows the front panel of a Cisco 1841 router. Figure 2-7 shows the back panel.
Figure 2-6 Front Panel of the Cisco 1841 Router
Cisco 1800 Series
Figure 2-7
7
SLOT 1
5
FE 0/1
4
CONSOLE
3
SLOT 0
2
CISCO 1841
1
100-240 VAC1A 50/60 Hz
CF
AIM
FE 0/0
AUX
9 10
11
5 12
13
2-8
122330
122329
SYS PWR
SYS ACT
OL-5876-03
Chapter 2
1 2 3 4 5 6 7
Input power connection On/Off switch Console port Fast Ethernet ports and LEDs Kensington
TM
8 9
Slot 0 (WIC, VWICdata only, or HWIC) 10 AIM LED 11 USB port 12 Aux port 13 Chassis ground connection security slot
Interface Numbering
Each individual interface (port) on a Cisco 1841 router is identified by a number. A Cisco 1841 router contains the following wide-area network (WAN) and local-area network (LAN) interface types:
Two onboard Fast Ethernet LAN interfaces Two slots in which you can install WICs, VWICs (data only), and HWICs.
The numbering format for the slots is interface-type 0/slot-number/interface-number. Table 2-6 summarizes the interface numbering.
Table 2-6 Interface Numbering
Slot Numbering Range 0/0 and 0/1 0/0/0 to 0/0/3 0/1/0 to 0/1/3
Example1 interface fastethernet 0/0 interface serial 0/0/0 line async 0/0/0 interface serial 0/1/0 line async 0/1/0
1. The interfaces listed are examples only; other possible interface types are not listed. 2. VWICs are data-only in a Cisco 1841 router.
Note
On the Cisco 1841 router, the numbering format for configuring an async interface is 0/slot/port. To configure the line associated with an async interface, simply use the interface number to specify the async line. For example, line 0/0/0 specifies the line associated with interface serial 0/0/0 on a WIC-2A/S in slot 0. Similarly, line 0/1/1 specifies the line associated with interface async 0/1/1 on a WIC-2AM in slot 1.
2-9
One onboard Fast Ethernet LAN interface (FastEthernet0/0) One onboard Ethernet switch One fixed VIC slot with 4 FXS ports One fixed VIC slot with 4 FXO or 2 BRI ports One modular HWIC/WIC/VWIC slot
The numbering format for the slots is interface-type 0/slot-number/port-number. Table 2-7 summarizes the interface numbering.
Table 2-7 Interface Numbering
Slot Number Onboard Ports Onboad Slot 1 Fixed HWIC slot 0 Fixed HWIC slot 1 Modular HWIC Slot
Slot Type Fast Ethernet Fast Ethernet Switch FXS FXO BRI HWIC/WIC/VWIC
Slot Numbering Range 0/0 0/1/0 to 0/1/7 0/0/0 to 0/0/3 0/1/0 to 0/1/3 0/1/0 to 0/1/1 0/3/0 to 0/3/x, where x depends on the card-type.
Example1 interface fastethernet 0/0 interface fastethernet 0/1/0 voice-port 0/0/0/ voice-port 0/1/0 interface serial 0/0/0
1. The interfaces listed are examples only; other possible interface types are not listed.
Note
On the Cisco 1861 ISR, the numbering format for configuring an asynchronous, or async, interface is 0/slot/port. To configure the line associated with an async interface, simply use the interface number to specify the async line. For example, line 0/0/0 specifies the line associated with interface serial 0/0/0 on a WIC-2A/S in slot 0. Similarly, line 0/1/1 specifies the line associated with interface async 0/1/1 on a WIC-2AM in slot 1.
Note
If you have specified the use of a private line automatic ringdown (PLAR) off-premises extension (OPX) connection mode for an FXO voice port (with loop resistance less than 8000 Ohm), you must ensure that the soft-offhook option is enabled on the port. This option allows a stepped offhook resistance during seizure, which avoids overloading the circuit during offhook in the event that ringing voltage is present on the circuit at the same time as the trunk seizure. The stepped offhook resistance is initially set to 800 Ohms, then adjusts to 50 Ohms when ringing voltage is not present. To enable the soft-offhook command on the port, and to access the connection command with plar opx syntax, see Cisco Command Lookup Tool.
2-10
OL-5876-03
Chapter 2
Specifications
Table 2-8 lists the specifications for Cisco 1800 series routers.
Table 2-8 1841 Router Specifications
Description Dimensions without rubber feet (H x W x D) Weight (no modules installed) Input voltage, AC power supply Frequency Power consumption
Specification 1.73 x 13.5 x 10.8 in. (4.4 x 34.3 x 27.4 cm) With rubber feet, height is 1.87 in. (4.75 cm) 6.1 lb. (2.77 kg) 100 to 240 VAC, autoranging 47 to 63 Hz 20 W maximum for an unloaded unit. With two WICs and an AIM installed, power consumption will be less than 50 W. RJ-45 connectors 5 to 95%, noncondensing 32 to 104F (0 to 40C) Normal operating temperature (< 78 F or 26 C): 34 dBa From (78 F or 26 C) through (104 F or 40 C): 37 dBa >104 F or 40 C: 42 dBa For detailed regulatory compliance information, see Regulatory Compliance and Safety Information for Cisco 1840 Routers, which accompanies the router. FCC Part 15 Class A. UL 60950; CSA 60950; IEC 60950; EN 60950; AS/NZS 3260; NOM-019-SCFI-1998.
Console and auxiliary ports Operating humidity Operating temperature Noise level
Regulatory compliance
Regulatory Compliance
For compliance information, see Regulatory Compliance and Safety Information for Cisco 1840 Routers document that accompanies the router.
2-11
2-12
OL-5876-03
CH A P T E R
Preinstallation Requirements and Planning for Cisco 1800 Series Routers (Modular)
This chapter describes the site requirements and equipment needed to install your Cisco 1800 series integrated services router (modular). It includes the following sections:
Safety Recommendations, page 3-1 General Site Requirements, page 3-3 Installation Checklist, page 3-4 Site Log, page 3-5 Inspecting the Router, page 3-6 Required Tools and Equipment for Installation and Maintenance, page 3-7
Note
To see translations of the warnings that appear in this publication, see Regulatory Compliance and Safety Information for Cisco 1840 Routers.
Safety Recommendations
Follow these guidelines to ensure general safety:
Keep the chassis area clear and dust-free during and after installation. If you remove the chassis cover, put it in a safe place. Keep tools and chassis components away from walk areas. Do not wear loose clothing that could get caught in the chassis. Fasten your tie or scarf, and roll up your sleeves. Wear safety glasses when working under conditions that might be hazardous to your eyes. Do not perform any action that creates a hazard to people or makes the equipment unsafe.
Warning
Read the installation instructions before connecting the system to the power source. Statement 1004
3-1
Preinstallation Requirements and Planning for Cisco 1800 Series Routers (Modular)
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place. Statement 1029
Warning
To prevent personal injury or damage to the chassis, never attempt to lift or tilt the chassis using the handles on modules (such as power supplies, fans, or cards); these types of handles are not designed to support the weight of the unit. Statement 1032
Warning
Ultimate disposal of this product should be handled according to all national laws and regulations. Statement 1040
Warning
When installing or replacing the unit, the ground connection must always be made first and disconnected last. Statement 1046
Warning
Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001
Warning
Read the installation instructions before connecting the system to the power source. Statement 1004
Warning
When installing or replacing the unit, the ground connection must always be made first and disconnected last. Statement 1046
Locate the emergency power-off switch in the room in which you are working. Then, if an electrical accident occurs, you can quickly turn off the power. Disconnect all power before doing the following:
Installing or removing a chassis Working near power supplies Removing the top cover of a chassis
Look carefully for possible hazards in your work area, such as moist floors, ungrounded power extension cables, frayed power cords, and missing safety grounds. Do not work alone if hazardous conditions exist. Never assume that power is disconnected from a circuit. Always check.
3-2
OL-5876-03
Chapter 3
Preinstallation Requirements and Planning for Cisco 1800 Series Routers (Modular) General Site Requirements
Never open the enclosure of the routers internal power supply. If an electrical accident occurs, proceed as follows:
Use caution; do not become a victim yourself. Turn off power to the device. If possible, send another person to get medical aid. Otherwise, assess the victims condition and
take appropriate action. In addition, use the following guidelines when working with any equipment that is disconnected from a power source, but is still connected to telephone wiring or other network cabling:
Never install telephone wiring during a lightning storm. Never install telephone jacks in wet locations unless the jack is specifically designed for it. Never touch uninsulated telephone wires or terminals unless the telephone line is disconnected at the network interface. Use caution when installing or modifying telephone lines.
Ensure that the router chassis is electrically connected to earth ground. Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to channel unwanted ESD voltages safely to ground. To guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is available, ground yourself by touching a metal part of the chassis.
Caution
For the safety of your equipment, periodically check the resistance value of the antistatic strap. It should be between 1 and 10 megohms (Mohm).
3-3
Preinstallation Requirements and Planning for Cisco 1800 Series Routers (Modular)
Warning
The device is designed for connection to TN and IT power systems. Statement 1007
Autoselects either 110 V or 220 V operation. All units include a 6-foot (1.8-meter) electrical power cord. (A label near the power cord indicates the correct voltage, frequency, current draw, and power dissipation for the unit.)
Site Environment
The location of your router is an extremely important consideration for proper operation. Equipment placed too close together-, or with inadequate ventilation-, or with inaccessible panels, can cause malfunctions and shutdowns, and can also make maintenance difficult. Plan for access to both front and back panels of the router. When planning your site layout and equipment locations, remember the precautions described in the Site Configuration section on page 3-4 to help avoid equipment failures and reduce the possibility of environmentally caused shutdowns. If you are currently experiencing shutdowns or an unusually high number of errors with your existing equipment, these precautions may help you isolate the cause of the failures and prevent future problems.
Site Configuration
The following precautions will help you plan an acceptable operating environment for your router and will help you avoid environmentally caused equipment failures:
Make sure that the room where your router operates has adequate circulation. Electrical equipment generates heat. Without adequate circulation, ambient air temperature may not cool equipment to acceptable operating temperatures. Always follow the ESD-prevention procedures described in the Preventing Electrostatic Discharge Damage section on page 3-3 to avoid damage to equipment. Damage from static discharge can cause immediate or intermittent equipment failure. Make sure that the chassis cover and module back panels are secure. All empty interface card slots must have filler panels installed. The chassis is designed to allow cooling air to flow within it, through specially designed cooling slots. A chassis with uncovered openings creates air leaks, which may interrupt and reduce the flow of air across internal components.
Installation Checklist
The sample installation checklist lists items and procedures for installing a new router. Make a copy of this checklist, and mark each item when you complete it. Include a copy of the checklist for each router in your Site Log (described in the Site Log section on page 3-5).
3-4
OL-5876-03
Chapter 3
Preinstallation Requirements and Planning for Cisco 1800 Series Routers (Modular) Site Log
Installation Checklist for Site_____________________________________________ Router Name_______________________________________________________ Task Installation Checklist copied Background information placed in Site Log Site power voltages verified Installation site power check completed Required tools available Additional equipment available Router received Router quick start guide received Cisco 1861 Integrated Services Router Quick Start Guide document received Product registration card received Cisco.com contact information label received Chassis components verified Initial electrical connections established ASCII terminal (for local configuration) or modem (for remote configuration) available Signal distance limits verified Startup sequence steps completed Initial operation verified Software image verified Verified by Date
Site Log
The Site Log is a record of all actions related to the router. Keep it in an accessible place near the chassis so that anyone who performs tasks has easy access to it. Use the Installation Checklist to verify steps in installation and maintenance of the router. Site Log entries might include the following information:
Installation progressMake a copy of the Installation Checklist, and insert it into the Site Log. Record the pertinent information as each procedure is completed. Upgrade and maintenance proceduresUse the Site Log as a record of ongoing router maintenance and expansion history. A Site Log might include the following events:
Installation of network modules Removal or replacement of network modules and other upgrades Configuration changes Maintenance schedules and requirements Maintenance procedures performed
3-5
Preinstallation Requirements and Planning for Cisco 1800 Series Routers (Modular)
Router 6-foot (1.8-meter) power cord Ground lug RJ-45-to-DB-9 console cable DB-9-to-DB-25 modem adapter Cisco 1800 Series Integrated Services Routers (Modular) Quick Start Guide Regulatory Compliance and Safety Information for Cisco 1840 Routers Cisco Router and Security Device Manager (SDM) Quick Start Guide Cisco.com card Product registration card
Inspect all items for shipping damage. If anything appears to be damaged, or if you encounter problems installing or configuring your router, contact customer service.
Items in the Box for the Cisco 1861 Integrated Services Router
The following items ship with the Cisco 1861 Integrated Services Router:
3-6
OL-5876-03
Chapter 3
Preinstallation Requirements and Planning for Cisco 1800 Series Routers (Modular) Required Tools and Equipment for Installation and Maintenance
Assembly hardware (screws) Installing Components for Cisco 1861 Integrated Services Router
Inspect all items for shipping damage. If anything appears to be damaged, or if you encounter problems installing or configuring your router, contact customer service.
Items not Included in the Box for the Cisco 1861 Integrated Services Router
You may need individual items in this list which are not shipped in the box:
Cisco Unified IP phones Cables for connecting phones Cable for connecting external audio device to the 3.5-mm MoH port Cables for WAN interfaces, voice interfaces, or additional LAN interfaces PC with Microsoft Internet Explorer 6.0 or later, for using web-based system management tools
ESD-preventive cord and wrist strap Number 2 Phillips screwdriver Flat-blade screwdrivers: small, 3/16-inch (0.48 centimeter) and medium, 1/4-inch (0.63 centimeter)
For installing or removing modules For removing the cover if you are upgrading memory or other components
Wire crimper AWG 14 wire for connecting the router chassis to earth ground
In addition, depending on the type of modules you plan to use, you might need the following equipment to connect a port to an external network:
Note
For more information on cable specifications, see the online document Cisco Modular Access Router Cable Specifications, which is located on Cisco.com.
Ethernet hub or PC with a network interface card for connection to Ethernet (LAN) ports Console terminal (an ASCII terminal or a PC running terminal emulation software) configured for 9600 baud, 8 data bits, no parity, and 1 stop bit Modem for connection to the auxiliary port for remote administrative access Data service unit (DSU) or channel service unit/data service unit (CSU/DSU) as appropriate for serial interfaces External CSU for any CT1/PRI modules without a built-in CSU
NT1 device for ISDN BRI S/T interfaces (if not supplied by your service provider)
3-7
Preinstallation Requirements and Planning for Cisco 1800 Series Routers (Modular)
3-8
OL-5876-03
CH A P T E R
Setting Up the Chassis, page 4-3 Installing the Chassis Ground Connection, page 4-11
Cisco 1800 series routers are normally shipped with a complement of components that can be upgraded or replaced to expand and enhance the routers functionality. These components either are inserted internally into the router or are plugged into slots in the router chassis.
Note
To see translations of the warnings that appear in this publication, see Regulatory Compliance and Safety Information for Cisco 1840 Routers.
Internal Components
If you need to remove or upgrade either of these items, follow the procedures given in the Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular) document.
Plug-In Components
WAN interface cards (WICs) Voice/WAN interface cards (VWICs), data mode only High-speed WICs (HWICs) CompactFlash memory card
If you need to remove or install WICs, VWICs, or HWICs, follow the procedures in the Installing Interface Cards in Cisco 1800 Series Routers (Modular) document. If you need to remove or upgrade the CompactFlash memory card, follow the procedure in the Installing and Replacing CompactFlash Memory Cards on Cisco 1800 Series Routers (Modular) document.
4-1
Chapter 4
The Cisco 1861 Integrated Services Router comes with various possible configurations, based on built-in ports and other hardware features of the Cisco 1861 Integrated Services Router and organized by model. Table 4-1 lists the labels and descriptions for the WAN, LAN, voice interface card (VIC), and other interfaces, along with the values for these interfaces in the preconfigured router software configuration.
Note
In Table 4-1, all slots/ports are numbered right to left, unless otherwise noted.
Table 4-1 Cisco 1861 Integrated Services Router: Interfaces
Description Console/Aux port Fast Ethernet 10/100 expansion port Fast Ethernet 10/100 WAN port
Value in Software Configuration FastEthernet0/1/8 FastEthernet0/0 FastEthernet0/1/0 to 0/1/7 port 0/0/0 to 0/0/3 port 0/1/0 to 0/1/3 Top-to-bottom, port 0/1/0 to 0/1/1 Vlan1 Vlan100 voice-port 0/4/0
Fast Ethernet 10/100 Power over Power over Ethernet, and Ethernet (PoE) ports ACT 0 LNK to ACT 7 LNK FXS (Foreign Exchange Station) FXS, and ports 0-3 FXO (Foreign Exchange Office) ports ISDN BRI ports VLAN number for data network Music-on-Hold (MoH) port Compact Flash slot (Factory Option) VIC: BRI* (Factory Option) VIC: FXO* COMPACT FLASH VIC2-2BRI-NT/TE and 0-1 VIC2-2FXO and 0-1 VIC2-4FXO and 0-3 (Factory Option) VIC: FXS* VIC3-2FXS/DID and 0-1 VIC-4FXS/DID and 0-3 VIC3-4FXS/DID and 0-3 FXO, and 0-3 B0 - B1
flash port 0/2/0 to 0/2/1 port 0/2/0 to 0/2/1 or port 0/2/0 to 0/2/3 port 0/2/0 to 0/2/1 or port 0/2/0 to 0/2/3
* Only one optional VIC can be factory installed in a Cisco 1861 Integrated Services Router. ** The label on the front panel is build-specific. Functionality is unaffected.
4-2
OL-5876-03
Chapter 4
Chassis Installation Procedures for Cisco 1800 Series Routers (Modular) Setting Up the Chassis
Setting the Chassis on a Desktop, page 4-3 Rack-Mounting a Cisco 1800 Series Modular-Configuration Router, page 4-3 Wall-Mounting the Chassis, page 4-6
Caution
The front panel bezel must not be removed from the Cisco 1841 router. It is part of the product's enclosure, and must be left in place to prevent damage from foreign objects entering the router, to provide a shield from internal electromagnetic interference (EMI), and to direct the flow of cooling air properly through the chassis.
Warning
To prevent personal injury or damage to the chassis, never attempt to lift or tilt the chassis using the handles on modules (such as power supplies, fans, or cards); these types of handles are not designed to support the weight of the unit. Statement 1032
Caution
Do not place anything on top of the router that weighs more than 10 lbs (4.5 kg). Excessive weight on top of the router could damage the chassis.
Caution
The Cisco 1861 Integrated Services Router installation must allow unrestricted airflow for cooling. For placing the platform on a desktop, keep at least 1 in. (2.54 cm) of clear space beside the cooling inlet and exhaust vents.
4-3
Note
To install a Cisco 1800 series modular-configuration router in a 19-inch rack, use the brackets included in the optional rack-mount kit (SKU: ACS-1841-RM-19=).All Cisco 1841 chassis shipping since Q4FY06 are rack-mountable. Cisco 1841 chassis with the following starting serial numbers have the rack-mount screw holes: FTX1009W0Z3 (United States), FCZ100812UR (Europe, Middle East, and Africa), and FHK100653JL (Asia Pacific).
Note
Brackets for 23-inch equipment racks are not available for Cisco 1800 series modular-configuration routers. Figure 4-1 shows the brackets.
Figure 4-1 Rack-Mounting Brackets
95769
CISCO
1841
100-240 VAC1A 50/60 Hz
4-4
OL-5876-03
127162
Chapter 4
Chassis Installation Procedures for Cisco 1800 Series Routers (Modular) Setting Up the Chassis
Tip
The screw slots in the brackets are spaced to line up with every second pair of screw holes in the rack. When the correct screw holes are used, the small threaded holes in the brackets line up with unused screw holes in the rack. If the small holes do not line up with the rack holes, you must raise or lower the brackets to the next rack hole.
Warning
To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in the rack. When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack. If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. Statement 1006
Warning
Take care when connecting units to the supply circuit so that wiring is not overloaded. Statement 1018
Warning
To prevent the system from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of 50C (122F). Statement 1047
Caution
Be sure to leave space above and below each router in a rack, to allow for cooling air circulation.
Figure 4-3 Mounting the Chassis in a Rack (Typical)
CISCO
1841
100-240 VAC1A 50/60 Hz
4-5
127168
Chassis Grounding
After the router has been installed, you must connect the chassis to a reliable earth ground. For the chassis ground connection procedure, see the Wall-Mounting the Cisco 1861 Integrated Services Router section on page 4-8.
Warning
This unit is intended to be mounted on a wall. Please read the wall mounting instructions carefully before beginning installation. Failure to use the correct hardware or to follow the correct procedures could result in a hazardous situation to people and damage to the system. Statement 248
6.00 inches
4-6
103162
OL-5876-03
Chapter 4
Chassis Installation Procedures for Cisco 1800 Series Routers (Modular) Setting Up the Chassis
Wall-mounting features
Install the two screws 6.00 in. (15.2 cm) horizontally apart on a wall or other vertical surface. The screws should protrude 0.25 in. (0.6 cm) from the surface of the wall.
Step 2 Step 3
Remove the rubber feet from the router. Hang the router on the screws, front panel down. This is the appropriate orientation for safe use. See Figure 4-5.
Figure 4-5 Wall-Mounting the Cisco 1841 Router
1 3
1 2
Router
Caution
If you install the screws in drywall, use hollow-wall anchors (1/8 in. (31.75 cm) by 5/16 in. (79.38 cm)) to secure the screws. If the screws are not properly anchored, the strain of the cables connected to the router back panel could pull the router from the wall.
103163
4-7
242657
Front panel
Mounting-screw holes
Align the mounting-screw holes with a wall stud, or use wall anchors.
a.
For attaching to a wall stud, use two #10 wood screws (round- or pan-head) with #10 washers, or two #10 washer-head screws. The screws must be long enough to penetrate at least 3/4 in. (20 mm) into the supporting wood or into a metal wall stud. For hollow-wall mounting, the wall must be at least 1/2 in. (12.7 mm) thick. Use two wall anchors with washers. The wall anchors and washers must be a size suitable for the wall to which they are mounted.
b.
Step 2
Orient the front and back of the chassis vertically. The unit must be oriented with the front panel (TNV connection side) facing up and the connection to the power cord facing down.
4-8
OL-5876-03
Chapter 4
Chassis Installation Procedures for Cisco 1800 Series Routers (Modular) Setting Up the Chassis
Step 3
Align the mounting-screw holes with a wall stud, or use wall anchors.
a.
For attaching to a wall stud, use two #10 wood screws (round- or pan-head) with #10 washers, or two #10 washer-head screws. The screws must be long enough to penetrate at least 3/4 inch (20 mm) into supporting wood or into a metal wall stud.
For hollow-wall mounting, the wall must be at least 1/2 in. (12.7 mm) thick. Use two wall anchors with washers. Wall anchors and washers must be a size suitable for the wall to which they are mounted.
b.
Figure 4-7 shows the wall-mount bracket for the power supply and the mounting-screw holes on the back of the bracket.
Figure 4-7 Wall-Mount Bracket for Power Supply
Step 4
Orient the front and back of the power supply vertically. Position the end nearest the power cable at the top.
Caution
Do not overtorque the screws. The recommended torque is 6 to 8 in-lb (0.7 to 0.9 N-m). Attach the mounting brackets to the Cisco 1861 Integrated Services Router chassis as shown in Figure 4-8, using the screws provided. Use four screws on each side. Use a number 2 Phillips screwdriver to install the bracket screws on both sides of the chassis.
Figure 4-8 Attaching Rack-Mount Brackets to the Cisco 1861 Integrated Services Router
Step 1
VIC 4FXS/DID 3 2 1
00
242658
0 IN USE
242684
4-9
Figure 4-9 shows the brackets in the rack-mount kit for the power supply.
Figure 4-9 Brackets for Rack-Mounting Power Supply
1
Step 2
Wall-mount bracket
Rack-mount bracket
Orient the front and back of the power supply vertically. Position the end nearest the power cable at the top.
Step 3
Assemble the brackets for rack-mounting the power supply as shown in Figure 4-10, using the four screws provided. Use a number 2 Phillips screwdriver to install the bracket screws.
Figure 4-10
242659
To mount the chassis and power supply, use two screws for each side (supplied with the rack) to attach the Cisco 1861 ISR with rack-mount brackets, then attach the power supply with rack-mount bracket to a 19-in. rack. Start the lower pair of screws first, resting the brackets on the lower screws while you insert the upper pair of screws.
4-10
242661
OL-5876-03
Chapter 4
Chassis Installation Procedures for Cisco 1800 Series Routers (Modular) Installing the Chassis Ground Connection
Warning
To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety: -- This unit should be mounted at the bottom of the rack if it is the only unit in the rack. -- When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack. -- If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. Statement 1006
Caution
Tip
The screw slots in the brackets are spaced to line up with every second pair of screw holes in the rack. When the correct screw holes are used, the small threaded holes in the brackets line up with unused screw holes in the rack. If the small holes do not line up with the rack holes, you must raise or lower the brackets to the next rack hole.
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024
Strip one end of the ground wire to expose approximately 0.75 in. (20 mm) of conductor. Crimp the 14 AWG green ground wire to a UL Listed/CSA certified ring terminal that is suitably sized for the number 6 ground screw provided on the rear panel of the router. The crimping tool should be one that is recommended by the ring lug terminal manufacturer. Attach the ring terminal to the chassis. The attachment points for the Cisco 1841 router are shown in Figure 4-11. Use a number 2 Phillips screwdriver and the screw supplied with the ground lug. Tighten the screw to a torque of 8 to 10 in-lb. (0.9 to 1.1 N-m).
Step 3
4-11
Figure 4-11
CISCO
1841
100-240 VAC1A 50/60 Hz
Step 4
Connect the other end of the ground wire to a known good electrical ground point. Consult with a licensed electrician if you have any questions about the suitability of the ground connection.
After the router is installed and properly grounded, you can connect the WAN and LAN cables as required for your installation. For cable connection procedures, see Cable Connection Procedures for Cisco 1800 Series Routers (Modular).
Installing the Chassis Ground Connection on the Cisco 1861 Integrated Services Router
You must connect the chassis to a reliable earth ground; the ground wire must be installed in accordance with local electrical safety standards. For NEC-compliant grounding, use size 14 AWG (2 mm) or larger copper wire and an appropriate user-supplied ring terminal with an inner diameter of 1/4 in. (5 to 7 mm).
Note
Warning
This equipment needs to be grounded. Use a green and yellow 14 AWG ground wire to connect the host to earth ground during normal use. Statement 190
To connect the chassis to a reliable earth ground, perform the following steps:
Step 1
Strip one end of the ground wire to the length required for the ground lug or terminal.
For the ground lug, approximately 0.75 in. (20 mm) For the user-provided ring terminal, as required
Step 2 Step 3
Crimp the ground wire to the ground lug or ring terminal, using a crimp tool of the appropriate size. Attach the ground lug or ring terminal to the chassis as shown in Figure 4-12. Tighten the screws to a torque of 8-10 in-lb (0.9-1.1 N-m).
4-12
117083
OL-5876-03
Chapter 4
Chassis Installation Procedures for Cisco 1800 Series Routers (Modular) Installing the Chassis Ground Connection
Figure 4-12
Step 4
Connect the other end of the ground wire to a known reliable earth ground point.
Note
If there is any doubt as to the reliability of the ground point, contact a licensed electrician for assistance.
230868
4-13
4-14
OL-5876-03
CH A P T E R
Cable Information and Specifications for Cisco 1800 Series Routers (Modular)
This chapter gives cable information and specifications for the console port, auxiliary port, and network ports on your Cisco 1800 series integrated services router (modular). It contains the following sections:
Console and Auxiliary Port Considerations, page 5-1 Preparing to Connect to a Network, page 5-2
For cable connection procedures, see Cable Connection Procedures for Cisco 1800 Series Routers (Modular).
5-1
Cable Information and Specifications for Cisco 1800 Series Routers (Modular)
The default parameters for the console port are 9600 baud, 8 data bits, no parity, and 1 stop bit. The console port does not support mode control. For cable and port pinouts, see Cisco Modular Access Router Cable Specifications.
Ethernet Connections, page 5-2 Serial Connections, page 5-3 ISDN BRI Connections, page 5-5 CSU/DSU Connections, page 5-5
See the following online documents for more information about network connections and interfaces:
Cisco Interface Cards Installation Guide Cisco Modular Access Router Cable Specifications
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030
Ethernet Connections
The IEEE has established Ethernet as standard IEEE 802.3. The Cisco 1800 series Ethernet implementations are as follows:
100BASE-T2-pair Category 5 or unshielded twisted-pair (UTP) straight-through RJ-45 cable. The maximum segment distance is 328 feet (100 meters). 10BASE-TEthernet on UTP cable. The maximum segment distance is 328 feet (100 meters). UTP cables look like the wiring used for ordinary telephones; however, UTP cables meet certain electrical standards that telephone cables might not meet.
5-2
OL-5876-03
Chapter 5
Cable Information and Specifications for Cisco 1800 Series Routers (Modular) Preparing to Connect to a Network
See Cisco Modular Access Router Cable Specifications for information about Ethernet cables, connectors, and pinouts.
Serial Connections
Serial connections are provided by serial WAN interface cards (WICs). For more information on WICs, see Installing Cisco Interface Cards in Cisco Access Routers. Before you connect a device to a serial port, you need to know the following:
Type of devicedata terminal equipment (DTE) or data communications equipment (DCE)that you are connecting to the synchronous serial interface Type of connectormale or femalethat is required for connecting to the device Signaling standard that is required by the device
Gender Male
1
Typical Devices
Female
1. If pins protrude from the base of the connector, the connector is male. 2. If the connector has holes to accept pins, the connector is female.
5-3
Cable Information and Specifications for Cisco 1800 Series Routers (Modular)
The synchronous serial port can be configured as DTE or DCE, depending on the attached cable (except EIA-530, which is DTE only). To order a shielded cable, contact customer service. See the Obtaining Documentation and Submitting a Service Request section on page 1-15.
Note
All serial ports configured as DTE require external clocking from a channel service unit/data service unit (CSU/DSU) or other DCE device. Although we do not recommend manufacturing your own serial cables (because of the small size of the pins on the DB-60 serial connector), cable pinouts are provided in Cisco Modular Access Router Cable Specifications.
Distance Limitations
Serial signals can travel a limited distance at any given bit rate; generally, the slower the data rate, the greater the distance. All serial signals are subject to distance limits, beyond which a signal is significantly degraded or completely lost. Table 5-2 lists the recommended maximum speeds and distances for each serial interface type; however, you might get good results at speeds and distances greater than those listed, if you understand the electrical problems that might arise and can compensate for them. For instance, the recommended maximum rate for V.35 is 2 Mbps, but 4 Mbps is commonly used.
Table 5-2 Serial Signal Transmission Speeds and Distances
Distance for EIA/TIA-232 Rate (bps) 2400 4800 9600 19200 38400 56000 1544000 (T1) Feet 200 100 50 25 12 8.6 Meters 60 30 15 7.6 3.7 2.6
Distance for EIA/TIA-449, X.21, V.35, and EIA-530 Feet 4100 2050 1025 513 256 102 50 Meters 1250 625 312 156 78 31 15
Balanced drivers allow EIA/TIA-449 signals to travel greater distances than EIA/TIA-232 signals. Typically, EIA/TIA-449 and EIA-530 can support a 2-Mbps rate, and V.35 can support a 4-Mbps rate.
Asynchronous interfaceMaximum baud rate is 115.2 kbps. Synchronous interfaceMaximum baud rate is 128 kbps, full-duplex.
5-4
OL-5876-03
Chapter 5
Cable Information and Specifications for Cisco 1800 Series Routers (Modular) Preparing to Connect to a Network
Warning
The ISDN connection is regarded as a source of voltage that should be inaccessible to user contact. Do not attempt to tamper with or open any public telephone operator (PTO)-provided equipment or connection hardware. Any hardwired connection (other than by a nonremovable, connect-one-time-only plug) must be made only by PTO staff or suitably trained engineers. Statement 23
Warning
Hazardous network voltages are present in WAN ports regardless of whether power to the unit is OFF or ON. To avoid electric shock, use caution when working near WAN ports. When detaching cables, detach the end away from the unit first. Statement 1026
Use a BRI cable (not included) to connect the BRI WIC directly to an ISDN. Table 5-3 lists the specifications for ISDN BRI cables. For information about pinouts, see Cisco Modular Access Router Cable Specifications.
Table 5-3 ISDN BRI Cable Specifications
Specification Resistance (at 96 kHz) Capacitance (at 1 kHz) Impedance (at 96 kHz) Wire diameter Distance limitation
1. nF = nanofarad.
High-Capacitance Cable 160 ohms/km 120 nF /km 75 ohms 0.024 in. (0.6 mm) 32.8 ft (10 m)
1
Low-Capacitance Cable 160 ohms/km 30 nF/km 150 ohms 0.024 in. (0.6 mm) 32.8 ft (10 m)
For more information on BRI WICs, see Installing Cisco Interface Cards in Cisco Access Routers.
CSU/DSU Connections
CSU/DSU WICs are available that provide switched 56-kbps connections, or full or fractionalized T1 connections. For more information on CSU/DSU WICs, see Installing Cisco Interface Cards in Cisco Access Routers.
5-5
Cable Information and Specifications for Cisco 1800 Series Routers (Modular)
5-6
OL-5876-03
CH A P T E R
Power Connections, page 6-1 Connecting WAN and LAN Cables, page 6-2 Connecting to a Console Terminal or Modem, page 6-3
For cable information and specifications, see the Cable Information and Specifications for Cisco 1800 Series Routers (Modular) document.
Note
To see translations of the warnings that appear in this publication, see the Regulatory Compliance and Safety Information for Cisco 1840 Routers.
Power Connections
Warning
Read the installation instructions before connecting the system to the power source. Statement 1004.
Note
The installation must comply with all required electrical codes applicable at the installation site. Connect your router to a 15 A, 120 VAC (10 A, 240 VAC) circuit with overcurrent protection.
Note
The input voltage tolerance limits for AC power are 85 and 264 VAC.
Warning
This product relies on the buildings installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 15A, 120VAC (10A, 240VAC). Statement 1005
6-1
Ports and Cabling, page 6-2 Connection Procedures and Precautions, page 6-3
Note
One or two Ethernet cables are typically provided with the router. You can order additional network connection cables and transceivers from Cisco. For ordering information, contact Cisco customer service. For cable pinouts, see Cisco Modular Access Router Cable Specifications.
Warning
Do not work on the system, or connect or disconnect cables during periods of lightning activity. Statement 1001
Cisco Modular Access Router Cable Specifications Cisco Interface Cards Installation Guide
WAN and LAN Connections
Table 6-1
T1/E1 WAN
RJ-48C
T1 or E1 network or CSU/DSU
Cisco serial transition cable that matches the signaling protocol (EIA/TIA-232, Cisco Smart CSU/DSU and serial EIA/TIA-449, V.35, X.21, compact connector, network or equipment or EIA/TIA-530) and the blue For WIC-2T and WIC-2A/S serial port operating mode only (DTE or DCE) See Cisco Modular Access Router Cable Specifications for information about selecting these cables.
6-2
OL-5876-03
Chapter 6
Cable Connection Procedures for Cisco 1800 Series Routers (Modular) Connecting to a Console Terminal or Modem
Table 6-1
Connected to:
Cable
Network demarcation RJ-11 straight-through for device for service providers 2-wire DSL interface RJ-14 straight-through for 4-wire NT1 device or PINX3 ISDN network PSTN RJ-48S interface RJ-45 straight-through RJ-49 straight-through RJ-11 straight-through RJ-48 straight-through
BRI S/T WAN (external NT12) BRI U WAN (built-in NT1) Analog modem 56/64-kbps CSU/DSU
1. The color codes are specific to cables shipped by Cisco. 2. NT1 = Network Termination 1. 3. PINX = Private integrated network exchange.
Position the cables carefully, so that they do not put strain on the connectors. Organize the cables in bundles so that cables do not intertwine. Inspect the cables to make sure that the routing and bend radiuses are satisfactory. Reposition the cables, if necessary. Install cable ties in accordance with your site requirements.
For cable pinouts, see Cisco Modular Access Router Cable Specifications.
This section describes how to connect a console terminal or PC to the console port and how to connect a modem to the auxiliary port. For information about cable pinouts, see Cisco Modular Access Router Cable Specifications.
6-3
Connect the end of the light blue console cable with the RJ-45 connector to the light blue console port on the router, as shown in Figure 6-1.
Figure 6-1 Connecting the Console Cable to the Router
CISCO
1841
100-240 VAC1A 50/60 Hz
1 3
1 2
Step 2
To PC or terminal
Connect the end of the cable with the DB-9 connector to the terminal or PC. If your terminal or PC has a console port that does not accommodate a DB-9 connector, you must provide an appropriate adapter for that port. (A DB-9-to-DB-25 adapter is provided with your router.)
Note
Because mode control is not possible on the console port, we do not recommend connecting modems to the console port. Modems should always be connected to the auxiliary port.
6-4
OL-5876-03
122332
Chapter 6
Cable Connection Procedures for Cisco 1800 Series Routers (Modular) Connecting to a Console Terminal or Modem
Step 1
Connect the RJ-45 end of the adapter cable to the black AUX port on the router. (See Figure 6-2.)
Figure 6-2 Connecting a Modem to the Router
CISCO
1841
100-240 VAC1A 50/60 Hz
1 2
Step 2 Step 3 Step 4
3 4
Connect the DB-9 end of the console cable to the DB-9 end of the modem adapter. Connect the DB-25 end of the modem adapter to the modem. Make sure that your modem and the router auxiliary port are configured for the same transmission speed (up to 115200 bps is supported) and for mode control with data carrier detect (DCD) and data terminal ready (DTR) operations.
Connect the AC power cord to the the power supply. Connect the power interface cable to the power connector port on the back of the Cisco 1861 Integrated Services Router.
6-5
122333
6-6
OL-5876-03
CH A P T E R
Note
To see translations of the warnings that appear in this publication, see the Regulatory Compliance and Safety Information for Cisco 1840 Routers.
Note
The Cisco 1861 Integrated Services Router supports a maximum of 12 user licenses based on different models.
The plug-socket combination must be accessible at all times because it serves as the main disconnecting device. Statement 1019
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place. Statement 1029.
Caution
To ensure adequate cooling, never operate the router unless the unit is completely closed.
7-1
Checklist for Power Up, page 7-2 LED Indicators, page 7-2 Power-Up Procedure, page 7-2
Mount and ground the chassis securely. Connect the power and interface cables. Make sure that the external CompactFlash memory card is properly seated into its slot. For installation instructions, see Installing and Replacing CompactFlash Memory Cards on Cisco 1800 Series Routers (Modular). Connect a PC to the routers console port. Start HyperTerminal or a similar terminal emulation program on your PC. Select the appropriate PC COM port. Set the terminal emulation program configuration for 9600 baud, 8 data bits, 1 stop bit, no flow control, and no parity.
Note
For initial power up, we recommend a direct console connection. After the intial configuration is completed, a remote modem connection can be used for router management.
Caution
To ensure adequate cooling, never operate the router unless the cover and all modules and cover plates are installed.
Caution
To prevent damage to the ejector mechanism, the ejector button next to the CompactFlash memory card must remain fully seated when not being used to eject a CompactFlash memory card.
LED Indicators
The meanings of the LED indicators for Cisco 1800 series routers are summarized in Table 2-5. For more detailed information about the LEDs, see Chapter 8, Troubleshooting Cisco 1800 Series Routers (Modular).
Power-Up Procedure
To power up your Cisco router and verify that it completes its initialization and self-test, follow this procedure. When you have completed the procedure you may begin configuring the router.
7-2
OL-5876-03
Chapter 7
Power-Up Procedures for Cisco 1800 Series Routers (Modular) Powering Up Cisco 1800 Series Routers
If you encounter problems when you power up the router, see Chapter 8, Troubleshooting Cisco 1800 Series Routers (Modular). For information about the ROM monitor and the bootstrap program, see the Using the ROM Monitor section of the Cisco 1800 Series Router Software Configuration. For information about the configuration register, see theChanging the Configuration Register Settings section of Cisco 1800 Series Router Software Configuration.
Note
To view the boot sequence through a terminal session, you must have a console connection to the Cisco router before the router powers up. To power up the router, perform the following steps:
Step 1 Step 2
Make sure that your PC is powered up and connected as described in the Checklist for Power Up section on page 7-2. Move the power switch to the ON position. The following indications appear:
The green SYS PWR LED on the front of the chassis comes on. The fan operates.
The LEDs on the chassis come on (although not necessarily at the same time), and some LEDs may go off again. The actual LED activity depends on your installation. If you encounter problems when you power up the router, see Troubleshooting Cisco 1800 Series Routers (Modular) Startup messages appear in your terminal emulation program window.
Caution
Do not press any keys on the keyboard until the messages stop. Any keys pressed during this time are interpreted as the first command typed when the messages stop, which might cause the router to power off and start over. It takes a few minutes for the messages to stop.
The startup messages vary, depending on the software installed on your router.
If the startup messages end with the following lines, you know that the Cisco Router and Security Device Manager (SDM) software is installed on the router.
yourname con0 is now available Press RETURN to get started!
For instructions on configuring your router by using SDM, see Cisco Router and Security Device Manager (SDM) Quick Start Guide.
Note
Because SDM is installed on your router by default, we recommend using SDM to perform the initial configuration. If the startup messages end with the following lines, the router is ready for initial configuration using the setup facility (system configuration dialog) or the command-line interface (CLI). Enter yes to continue with the setup facility; enter no to continue with the CLI.
7-3
. --- System Configuration Dialog --At any point you may enter a question mark '?' for help. Use ctrl-c to abort configuration dialog at any prompt. Default settings are in square brackets '[]'. Would you like to enter the initial configuration dialog? [yes/no]:
Note
If the rommon 1> prompt appears, your system has booted in ROM monitor mode. For information about the ROM monitor and the bootstrap program, see the Using the ROM Monitor section in Cisco 1800 Series Router Software Configuration.
Status Router has successfully booted up and the software is functional. Slow, steady blinking when system is booting or in the ROM monitor. Blinking when packets are transmitted or received on any WAN or LAN interface, or when monitoring system activity. Flash memory is busy. Do not remove the CompactFlash memory card when this light is on.
7-4
OL-5876-03
Chapter 7
Power-Up Procedures for Cisco 1800 Series Routers (Modular) Verifying the Hardware Configuration
Figure 7-1
LEDs on the Front Panel of the Cisco 1861 Integrated Services Router
4 3 2 1
1 2 3 4
230870
show versionDisplays the system hardware version, the installed software version, the names and sources of configuration files, the boot images, and the amount of installed DRAM and flash memory. show diagLists and displays diagnostic information about the installed controllers and interface processors. Typical examples are interface cards (VWICs, WICs, HWICs), and advanced integration modules (AIMs).
Initial Configuration, page 7-5 Verifying the Initial Configuration, page 7-6 Completing the Configuration, page 7-6
Initial Configuration
You can configure your router by using one of the following tools:
7-5
Cisco Router and Security Device ManagerSee the Cisco Router and Security Device Manager section on page 7-6 Setup command facilitySee the Initial Configuration Using the Setup Command Facility section in the Cisco 1800 Series Integrated Services Routers (Modular) Quick Start Guide. Command-line interface (CLI)See the Initial Configuration Using Cisco CLIManual Configuration section in the Cisco 1800 Series Integrated Services Routers (Modular) Quick Start Guide.
For instructions on configuring your router by using SDM, see the Cisco Router and Security Device Manager (SDM) Quick Start Guide. To use SDM, you can download the latest version of SDM and instructions for installing it on your router: http://www.cisco.com/pcgi-bin/tablebuild.pl/sdm To obtain the SDM quick start guide, SDM release notes, and other SDM documentation, go to www.cisco.com/go/sdm.
Enter the show interfaces command to verify that the interfaces are operating correctly and that the interfaces and line protocol are in the correct stateup or down. Enter the show ip interface brief command to display a summary status of the interfaces configured for IP. Enter the show configuration command to verify that you configured the correct hostname and password.
When you have completed and verified the initial configuration, your Cisco router is ready to be configured for specific functions. See the Completing the Configuration section on page 7-6 for information about locating documentation for advanced configuration procedures.
7-6
OL-5876-03
Chapter 7
Power-Up Procedures for Cisco 1800 Series Routers (Modular) Powering up the Cisco 1861 Integrated Services Router
Feature documentation Troubleshooting and maintenance Cisco 1800 series cards and modules
Verify that the AC power cord is connected to the power supply. Power up the power supply and the Cisco 1861 ISR, by connecting the power cord plug to a grounded AC outlet.
Note Step 3
Verify the LED indicators on the front panel of the Cisco 1861 Integrated Services Router, as required. See Figure 7-1.
Software Component Cisco Unified Communications Manager Express (Cisco Unified CME)
Description Entry-level call processing system that provides a wide range of IP telephony features for small to medium-sized business customers and autonomous small enterprise branch offices. Provides voice mail and automated attendant services specifically designed for the small and medium-sized branch office environment.
Benefits All files and configurations for IP phones are stored internally on the Cisco 1861 Integrated Services Router for a cost-effective, highly reliable, IP communications solution.
Users can easily and conveniently manage their voice messages and greetings with intuitive telephone prompts and a straightforward web-based GUI that allows simple administration
7-7
Table 7-2
Description
Benefits
Protects against Integrated for a robust array of security features. information theft, virus outbreaks, and application abuse, whether from known or unknown threats, internal or external sources. Protects customer Help businesses guarantee network uptime and networks against network security. and application layer attacks, viruses, and worms, and at the same time provides effective control on various application traffic flowing through the network. Carries private data over a Most cost-effective method to provide increased public network and VPN throughput with minimal effect on extends remote access to processing. users over a shared infrastructure.
7-8
OL-5876-03
CH A P T E R
Problem Solving, page 8-1 Reading LEDs, page 8-4 System Messages, page 8-5 Recovering a Lost Password, page 8-6 More Troubleshooting Help, page 8-6
Note
To troubleshoot interface cards, see Overview of Cisco Interface Cards for Cisco Access Routers. If you cannot locate the source of the problem, contact a Cisco customer service representative for information on how to proceed. For technical support information, see the Obtaining Documentation and Submitting a Service Request section on page 1-15. Before you call, have the following information ready:
Chassis type and serial number Maintenance agreement or warranty information Type of software and version number Date you received the router Brief description of the problem Brief explanation of the steps you have taken to isolate the problem
Problem Solving
The key to problem solving is to isolate the problem to a specific subsystem by comparing what the router is doing to what it should be doing. The LEDs on the router aid you in determining router performance and operation. The LEDs are described in the Reading LEDs section on page 8-4.
8-1
Power and cooling systemsExternal power source, power cable, router power supply, circuit breaker, and router fan. Also check for inadequate ventilation or air circulation. Interface cardsLEDs on the interface cards help identify a failure. CablesExternal cables that connect the router to the network.
Normal Indications
With the power switch on, the normal indications are:
Fault Indications
Check the following symptoms to locate or eliminate faults in the power and cooling systems:
With the power switch on, is the SYS PWR LED on?
If the LED is green and continuous, the router is receiving power and is functional. If the LED is off, check the power source and power cable.
With the power switch on and the SYS PWR LED on and green, does the fan operate?
If no, check the fan. If yes, the power system is functioning.
With the power switch on and the SYS PWR LED off, does the fan operate?
If yes, the router is receiving power. The fan is connected directly to the DC outputs of the power
supply.
If no, check the power source and power cable.
page 3-3.
Check for a power supply failure by inspecting the SYS PWR LED on the front panel. If it is
router. If the SYS PWR LED is blinking or continuously green, the power supply is functional.
If the SYS PWR LED is not on, see Cisco One-Year Limited Hardware Warranty Terms
8-2
OL-5876-03
Chapter 8
Fan failure Air conditioner failure in the room Air blockage to cooling vents
Take steps to correct the problem. See the Site Environment section on page 3-4.
software requirements for the affected card, which can be found in the configuration note for the card.
(a) The same data rate as configured for the router (9600 baud is the default) (b) 8 data bits (c) 1 stop bit (d) No parity generated or checked
page 1-14 and the Obtaining Documentation and Submitting a Service Request section on page 15 of the Introduction to Cisco 1800 Series Routers (Modular) Hardware Documentation document for warranty and customer service contact information.
8-3
There may be a problem with the card or cable. See the Cisco One-Year Limited Hardware
Warranty Terms and the Obtaining Documentation and Submitting a Service Request sections of the Introduction to Cisco 1800 Series Routers (Modular) Hardware Documentation document for warranty and customer service contact information.
Reading LEDs
The LEDs on the router enable you to determine router performance and operation. The System Power (SYS PWR) LED and the System Activity (SYS ACT) LED are on the front panel; all the other LEDs are on the back panel.
Table 8-1 LED Indicators on Cisco 1800 Series Routers
State Off
Possible Causes and Corrective Actions Power is not switched on at the router. Power is not available from the source. Faulty input power wires or connections are missing. Failed power supply in the router. To replace the internal power supply, call your Cisco technical support representative.
Solid green
Router is receiving power, and Normal indication. No action is the internal power supply is required. functional. During bootup, router is booting up normally. After bootup, router is operating in ROM monitor mode. Normal indication. No action is required. See the router rebooting and ROM monitor information in the Cisco 1800 series software configuration documentation. Interface card connections are not functional. Router is not configured properly. Check configuration, and make corrections as necessary.
Blinking green
SYS ACT
Off
Blinking
System is actively transferring Normal indication. No action is packets and monitoring required. internal activity
8-4
OL-5876-03
Chapter 8
Table 8-1
LED Indicator
State
Possible Causes and Corrective Actions Normal indication. No action is required. It is okay to remove the CompactFlash memory card if the CF LED remains off. Normal indication. No action is required.
Caution
FDX
Off
Solid green
Fast Ethernet port next to the Indication is for information only. LED is operating in full-duplex mode. Fast Ethernet port next to the LED is operating at 10 Mbps. Indication is for information only.
100
Fast Ethernet port next to the Indication is for information only. LED is operating at 100 Mbps. Fast Ethernet link is not Ethernet is not active or is not established at the Ethernet port connected. Check Ethernet next to the LED. connections. Router is not configured properly. Check configuration, and make corrections as necessary.
Link
Off
Solid green
FastEthernet link is established Normal indication. No action is at the Ethernet port next to the required. LED. No AIM is installed. AIM is recognized by the router and is initialized. Indication is for information only. Normal indication. No action is required.
System Messages
This section describes system error and recovery messages that may appear when a Cisco 1800 series router is operated. The Cisco IOS software displays system error and recovery messages on an external device console terminal screen. (For more information, see the Connecting to the Console Port section on page 6-4.)
8-5
(indicates the user EXEC command mode) (indicates the privileged EXEC command mode)
or
Router#
The Cisco IOS software checks the system condition once every 30 seconds. If a condition still exists, the error message is displayed again; if the error condition has cleared, a recovery message is displayed. Table 8-2 describes some of the most common system error and recovery messages.
Table 8-2 System Messages
%ENVMON-3-FAN_FAIL: Fan <fan-number> is The cooling fan within the chassis is not working. malfunctioning %CFG-3-CARD_NOT_SUPPORTED: Slot <n>. <Card identification from cookie, including at least card type, version, revision, and serial number> The card found is not recognized or is not supported in the specified slot.
%CFG-6-UNKNOWN_AIM: AIM module in This Cisco IOS image does not have the driver AIM slot <n> is not supported by this IOS image. code for the AIM discovered in AIM slot. Card info: <all TLV PEP data from cookie>
8-6
OL-5876-03
CH A P T E R
Voice-WAN interface cards (VWICs)data only on the Cisco 1841 router WAN interface cards (WICs) High-speed WAN interface cards (HWICs)
You can view the Cisco Interface Cards Installation Guide on Cisco.com.
Cisco Network Modules and Interface Cards Regulatory Compliance and Safety Information
Do not connect a WAN cable to an interface card until you have completed its installation procedure. The Cisco 1841 router has two interface card slots. Each slot can accommodate a Cisco WIC, VWIC (data only mode), or a single-wide high-speed WIC (HWIC).
Note
Cisco double-wide HWICs are not supported in the Cisco 1841 router.
9-1
Make sure that the router is turned off and is disconnected from power.
Caution
Power must be removed from the system prior to installing or removing interface cards to avoid damaging them. When interface cards are pushed into or pulled out of a router that is powered up, there is a strong possibility that they could be damaged electrically and would no longer function. Loosen the thumbscrews on the interface card blank faceplate on the back panel, as shown in Figure 9-1. You should be able to loosen the screws using your fingers; however, if the screws are very tight, you might need to use a Phillips screwdriver.
Figure 9-1 Removing an Interface Card Blank Faceplate
Step 2
CISCO
1841
100-240 VAC1A 50/60 Hz
1
Step 3 Step 4
Blank faceplate
Remove the blank faceplate that covers the card slot. Hold the interface card by the edges on either side of the card front panel, and line up the card edges with the guides inside the card slot, as shown in Figure 9-2.
Figure 9-2 Inserting an Interface Card into the Router
TD
RD
LP
AL
CD
DSU 56K
CISCO
1841
100-240 VAC1A 50/60 Hz
1 2
Card guides
Interface card
9-2
OL-5876-03
95768
95767
Chapter 9
Installing Interface Cards in Cisco 1800 Series Routers (Modular) Installing WICs, VWICs, and HWICs
Step 5 Step 6
Insert the card in the slot, and gently push it into the router until the front panel of the card is flush with the back panel of the router. Tighten the screws.
9-3
9-4
OL-5876-03
CH A P T E R
10
Installing and Replacing CompactFlash Memory Cards on Cisco 1800 Series Routers (Modular)
This chapter describes installing and replacing CompactFlash memory cards in Cisco 1800 series integrated services routers (ISR) (modular). You can perform these procedures when the router has been installed in its working location with all power and interface cables connected. This chapter contains the following sections:
Preventing Electrostatic Discharge Damage, page 10-1 Replacing CompactFlash Memory Cards, page 10-1
Always use an ESD wrist or ankle strap and ensure that it makes good skin contact. Connect the equipment end of the strap to an unfinished chassis surface. Place a removed CompactFlash memory card on an antistatic surface or in a static shielding bag. If the card will be returned to the factory, immediately place it in a static shielding bag. Avoid contact between the card and clothing. The wrist strap protects the card from ESD voltages on the body only; ESD voltages on clothing can still cause damage. Do not remove the wrist strap until the installation is complete.
Caution
For safety, periodically check the resistance value of the antistatic strap. The measurement should be between 1 and 10 megohms (Mohms).
10-1
Chapter 10
Installing and Replacing CompactFlash Memory Cards on Cisco 1800 Series Routers (Modular)
Caution
If the CF LED is on or blinking, do not remove the CompactFlash memory card. The router could crash, or the flash memory contents could be corrupted.
Press the ejector button next to the CompactFlash memory card. The ejector button moves outward so that it projects from the panel. Press the ejector button again to unseat the card. Carefully pull the card out of the slot. Place the removed CompactFlash memory card on an antistatic surface or in a static shielding bag. Push the ejector button in until it clicks.
Caution
To prevent damage to the ejector mechanism, the ejector button must remain fully seated when not being used to eject a CompactFlash memory card.
Make sure that the ejector button is fully seated so that it does not project from the panel.
Note Step 2
If the ejector button projects from the panel, push it in until it clicks. With the label facing up, insert the connector end of the CompactFlash memory card into the slot until the card is seated in the connector. The card is keyed so that it cannot be inserted incorrectly.
Note
If the ejector button projects from the panel after you insert the CompactFlash memory card, remove the card, press the ejector button until it clicks, and reinsert the card.
Caution
To prevent damage to the ejector mechanism, the ejector button must remain fully seated when not being used to eject a CompactFlash memory card.
10-2
OL-5876-03
Chapter 10
Installing and Replacing CompactFlash Memory Cards on Cisco 1800 Series Routers (Modular)
Note
A small flat-head screwdriver is required to attach the CF-guard. To install the CF-guard, follow these steps:
Step 1
Step 2 Step 3
Slip the CF-guard flap into the notch in the CompactFlash memory slot. Screw the CF-guard into the screw hole.
158076
10-3
Chapter 10
Installing and Replacing CompactFlash Memory Cards on Cisco 1800 Series Routers (Modular)
10-4
OL-5876-03
CH A P T E R
11
Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular)
This chapter describes how to install or upgrade modules that are located internally within the Cisco 1800 series integrated services routers (modular): memory modules and advanced integration modules (AIMs). You need to remove the cover from the router to install or remove any of these items. The chapter contains the following sections:
Safety Warnings, page 11-1 Modules Internal to the Cisco 1841 Router, page 11-2
Note
To see translations of the warnings that appear in this publication, see the Regulatory Compliance and Safety Information for Cisco 1840 Routers.
Safety Warnings
Warning
Before working on a system that has an on/off switch, turn OFF the power and unplug the power cord. Statement 1
Warning
Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals. Statement 43
Warning
During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94
Warning
Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001
Warning
Read the installation instructions before you connect the system to its power source. Statement 1004
11-1
Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular)
Warning
Hazardous network voltages are present in WAN ports regardless of whether power to the router is OFF or ON. To avoid electric shock, use caution when working near WAN ports. When detaching cables, detach the end away from the router first. Statement 1026
Opening the Chassis, page 11-2 Locating Modules, page 11-4 Installing a SODIMM, page 11-5 Installing an AIM, page 11-6 Closing the Chassis, page 11-11
All the module replacement procedures in this section require removal of the chassis cover. Before you perform any of the module replacement procedures, disconnect the power and remove the cover as described in the Opening the Chassis section on page 11-2. After you complete the module replacement procedures, install the chassis cover as described in the Closing the Chassis section on page 11-11.
Make sure that the router is turned off and is disconnected from AC power. Turn the router upside down, and rest the top of the router on a flat surface. Use the Phillips screwdriver to remove the screw that holds the top and bottom of the chassis together, as shown in Figure 11-1.
11-2
OL-5876-03
Chapter 11
Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular) Modules Internal to the Cisco 1841 Router
Figure 11-1
1
Step 4
Insert a flat-head screwdriver into the slots at the screwdriver pry points and rotate the screwdriver 90 degrees to disengage the top cover from the chassis. See Figure 11-2.
Figure 11-2 Screwdriver Pry Points
1 1
1
Step 5 Step 6
Turn the router back to its original position (top up). Gently slide the top of the router (which is facing up toward you) away and up from the bottom of the router (which is resting on the flat surface). See Figure 11-3.
121041
103164
11-3
Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular)
Figure 11-3
2 1
103165
1
Step 7
Place the router bottom on an antistatic mat, and begin installing memory.
Locating Modules
Figure 11-4 shows where the connector for the SODIMM or the AIM is located on the Cisco 1841 motherboard.
11-4
OL-5876-03
Chapter 11
Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular) Modules Internal to the Cisco 1841 Router
Figure 11-4
10 6
9 8 7
11
1 2 6 1 5 4
95906
1 2 3 4 5 6
Ground screw Interface card slot 0 USB port CompactFlash memory card slot Interface card slot 1 Safety shields for WIC/HWIC slots and connectors
7 8 9
Caution
Do not, under any circumstances, tamper with or attempt to remove the safety shields protecting the WIC/HWIC slots and connectors.
Installing a SODIMM
You can install a SODIMM to increase the amount of DRAM in the router. To install a SODIMM on the router motherboard, follow these steps:
Step 1 Step 2
Locate the SODIMM socket on the motherboard. Remove any existing SODIMM by gently pulling the spring-loaded clips on the end of the socket far enough to clear the SODIMM, and gently pulling the SODIMM up and away from the socket. See Figure 11-5.
11-5
Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular)
Figure 11-5
Removing a SODIMM
1 2
Step 3
103155
SODIMM socket
Insert the SODIMM into the SODIMM socket, as shown in Figure 11-6.
Figure 11-6 Installing a SODIMM
2 3
103154
1 2
Step 4
Spring-loaded clips
Firmly press the SODIMM into the socket until the spring-loaded clips on the socket snap over the end of the SODIMM.
Installing an AIM
The Cisco 1841 router has the capability to support a single AIM module. To install an AIM, follow the procedure given here.
11-6
OL-5876-03
Chapter 11
Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular) Modules Internal to the Cisco 1841 Router
Table 11-1
Type Unity Express Unity Express AXPApplication eXtension Platform Intrusion Prevention Systems VPN Encryption
Caution
When you install an AIM, always wear an ESD-preventive wrist strap, and ensure that it makes good contact with your skin. Connect the equipment end of the wrist strap to the metal part of the chassis.
Caution
Handle AIMs by the edges only. AIMs are ESD-sensitive components and can be damaged by mishandling.
Installation Procedure
To install the AIM, perform the following steps. You need a number 2 Phillips screwdriver or flat-head screwdriver to complete this procedure.
Step 1
Find the metal standoff attachment locations on the system board near the AIM connector, indicated by a star pattern, as shown in Figure 11-7.
11-7
Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular)
Figure 11-7
System board
AIM connector
Step 2
Install the two metal standoffs from the accessory kit into the system board in the metal standoff attachment locations, as shown in Figure 11-9. Use a 1/4-inch nut driver to tighten the standoffs. Locations for AIM standoffs are denoted by a star pattern around the standoff mounting holes.
Caution
Make sure that the standoffs are installed straight. Tighten them gently but firmly. The shoulder must be seated tightly against the system board. Insert the plastic standoff (Figure 11-8) from the accessory kit into the hole in the system board. See Figure 11-9. Press the standoff firmly into the system board to be sure that it is locked to the board.
Step 3
Note
The plastic standoff snaps into the system board. Be sure to insert the locking end of the standoff into the system board. The locking end is the shortest end of the standoff. Figure 11-8 identifies the locking end of the plastic standoff used with AIMs.
Note
For most AIMs, the plastic snap-in standoff is white. For the AIM2-CUE-K9 and the AIM2-APPRE-104-K9, the plastic standoff is blue and has a slightly larger snap-in feature to accomodate the PCB which is thicker.
11-8
121107
OL-5876-03
Chapter 11
Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular) Modules Internal to the Cisco 1841 Router
Figure 11-8
AIM end
Locking end
Step 4
Insert the connector on the AIM into the AIM connector on the system board. See Figure 11-9.
Note
Be sure to press firmly on the AIM until the board seats onto the connector. The plastic standoff must snap into the hole in the AIM board. See Figure 11-9.
Step 5
Insert the screws from the accessory kit through the AIM into the metal standoffs. See Figure 11-9. Carefully tighten the screws with a Phillips screwdriver.
82620
11-9
Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular)
Figure 11-9
AIM
Metal standoffs
Step 6
Check that the AIM is installed correctly on the system board. See Figure 11-10.
11-10
121108
OL-5876-03
Chapter 11
Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular) Modules Internal to the Cisco 1841 Router
Figure 11-10
If the chassis label is attached to the label on the AIM card, carefully tear off the chassis label at the perforation. If the chassis label is in the AIM mounting kit, remove the label from the kit bag. Peel the chassis label from its backing. If there is a suitable space, apply the chassis label to the back of the chassis. If no suitable space is available on the back of the chassis, apply the label to the top cover at the back edge. The label must be visible with the chassis installed.
Note
Do not apply the AIM label for the chassis to a blank cover plate; to any removable network module or interface card; or over any holes, screws, chassis vents, or existing labels.
Rotate the cover down onto the chassis. Slide the cover back onto the bottom of the chassis. See Figure 11-11. Push firmly to close. Turn the router upside-down.
58696
11-11
Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular)
Step 4
Use a number 1 Phillipsscrewdriver to reinstall the screw that holds the cover to the chassis. See Figure 11-1.
Figure 11-11 Closing the Chassis
1 2
103166
11-12
OL-5876-03
Index
A
ACT LED in Cisco 3725 auxiliary port connecting to a modem
6-5 to ?? 8-4
I
installation rack-mounting installing wall-mounting IOS software
4-6 4-3 to ??
C
Caution symbol, meaning of chassis desktop installation rack-mounting Cisco IOS software locating documentation connecting router to a PC connections serial
5-3 ?? to 6-4 1-14 4-3 4-3 to ?? 1-7
locating documentation
1-14
L
LEDs rear panel
8-4
P
PC connecting to router PWR LED in Cisco 3725
?? to 6-4 8-4
D
desktop installation documentation Cisco IOS software conventions on CD-ROM on the WEB related
1-13 1-7 1-13 1-13 1-14 4-3
R
rack-mounting the chassis router connecting to a PC
?? to 6-4 4-3 to ??
T
Tables document conventions
1-7 8-4 1-14
F
Figures rack-mounting the chassis
4-5
LEDs on front panel related documents troubleshooting high temperature WICs and VICs
8-3 8-3
H
high temperature, troubleshooting
8-3
IN-1
Index
V
VICs troubleshooting
8-3
W
wall-mounting Warnings WAN port voltages WICs troubleshooting
8-3 5-5 4-6
IN-2
OL-5876-03