MANHOLE ANALYSIS AND DESIGN


______________________________________________________
PROJECT

Palm Tree Design-30 Mtr

POLE
Shape
Base Diameter
Top Diameter
Length
Taper
Manhole location
Diam at Bottom of Manhole
Diam at Top of Manhole

ROUND
1285 mm
825 mm
26.5 m
17.358 mm/m
600 mm
1275 mm
1258 mm

Diam @ Manhole Location =


Pole Thickness @ Manhole Location =
Material =

MANHOLE
___________

49.86 in
0.39 in
50.00 Ksi

Size (Width x Height) =


Stiffener Thickness =
Material =
Outside Width =
Inside Width =
Double Plate (Thickness x Width) =
Material =

1267 mm
10 mm
355 MPa

530
20.87
1.18
50
0.00

mm x
in x
in
Ksi
in

930
36.61
30.00
355
0

mm
in
mm
MPa
mm

5.12
1.8
45.0
36

in
in x
mm x
Ksi

130
5.1
130
250

mm
in
mm
MPa

PROPERTIES
___________
Minimum
Requirement

Area (in2)

Pole With
Handhole

CHECK

61.81

63.32

OK

Mom. Inertia Ix (in4)

8509.33

15115.02

OK

Mom. Inertia Iy (in4)

8509.33

15585.78

OK

Sect. Modulus Sy (in3)

341.31

606.27

OK

1/(KL/r)

0.0093

0.0391

OK