Quidway S8500 Series 10G Core Routing Switches: Huawei Technologies Co., LTD
Quidway S8500 Series 10G Core Routing Switches: Huawei Technologies Co., LTD
Quidway S8500 Series 10G Core Routing Switches: Huawei Technologies Co., LTD
Contents
Product Overview ......................................................................... 1 Product Features .......................................................................... 2 Product Specifications .................................................................. 4 Standards and Specifications Compliance ..................................... 8 Ordering Information ................................................................. 12 Applications ............................................................................... 17
Copyright 2006 by Huawei Technologies Co., Ltd. All Rights Reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.
S8512
S8508
S8505
S8502
Huawei Datacom
Quidway S8500 Series 10G Core Routing Switches
Product Features
The S8500 series adopts numerous industry-leading features to realize the promise of top-ranking services, performance and availability with investment protection for enterprise and service provider IP communication markets, including:
RPR Solution
The S8500 will offer 10G RPR interface module in Q1/2006. The RPR (Resilient Packet Ring) technology combines advantages of SDH network and Ethernet, such as fault self-healing and cost-effectiveness for SDH, high bandwidth, high flexibility and expansibility for Ethernet. In addition, as RPR is based on ring technology, it can provide advanced features like highly efficient bandwidth management, automatic topology discovery, QoS guarantee, etc.
Huawei Datacom
Quidway S8500 Series 10G Core Routing Switches
The S8500 series symbolizes the 10GE network practices by providing powerful QoS guarantee, rich services features such as ACL, strategic routing and security, wire-speed MPLS forwarding, IP VPN services and transparent LAN services.
Product Specifications
Key specifications of S8500 series switches are given in Table 1 ~ Table 5. Table 1 S8500 Series Software and Hardware Attributes
Attributes
Switching Capacity Backplane Capacity Packet Forwarding Speed Number of Slots
S8502
240 Gbps 450 Gbps 143 Mpps 4
S8505
300 Gbps 750 Gbps 178 Mpps 7
S8508
480 Gbps 1.2 Tbps 285 Mpps 10
S8512
720 Gbps 1.8 Tbps 428 Mpps 14
Attributes
Number of Slots for Interface Modules 2/3
S8502
5
S8505
8
S8508
12
S8512
L2 Features
4K VLAN Super VLAN PVLAN 802.1p priority 802.1Q STP/RSTP/MSTP GARP/GVRP IGMP snooping Port mirroring Flow mirroring Link aggregation (802.3ad) Cross boards link aggregation LACP 802.1x Guest VLAN Dynamic VLAN Broadcast storm suppression MDI/MDI-X auto-negotiation HWTACACS Selective QinQ (Class D interface module supported) 14K per card 42K per system (VLAN non-cross cards) 14K per card 70K per system (VLAN non-cross cards) 14K per card 112K per system (VLAN non-cross cards) 14K per card 168K per system (VLAN non-cross cards)
L3 Features
RIPv1, RIPv2, OSPF, IS-IS, BGPv4 Equal Cost Multi Path: 8 Policy routing Routing policy uRPF (NAT service module supported) VRRP DHCP-RELAY DHCP-SERVER NAT IGMPv2 IGMP snooping PIM-DM PIM-SM MSDP/MBGP Any-RP Label stack levels: 4 LER/LSR MCE Embedded MPLS VPN HoPE Inter-AS MPLS VPN
Multicast
MPLS VPN
Huawei Datacom
Quidway S8500 Series 10G Core Routing Switches
Attributes
S8502
S8505
S8508
S8512
VPLS VSI number: 1K Mac table: 128/VSI,128K (total) VPLS Martini method H-VPLS VLL VC number: 4K VLL Martini method VLL Kompella method DiffServ Each port supporting 8 priority queues Detailed bandwidth management with the granularity of 8K Congestion prevention algorithm: WRED and tail drop Queue scheduling algorithms: SP, WRR and SP+WRR Traffic shaping MTBF > 200,000 hours MTTR < 0.5 hours Dual main control boards 1+1 power supplies Modules hot-swappable Integrated chassis that can be installed in a 19-inch rack 436 x 420 x 265 40 kg 436 x 450 x 486 65 kg 436 x 450 x 619 80 Kg 436 x 450 x 753 100 kg
QoS
Reliability
System Architecture Dimension (mm) (WDH) Weight (full configuration) Environmental Requirement
S8502
100 ~ 240 VAC auto-ranging (50 ~ 60Hz)
S8505
100 ~ 240 VAC auto-ranging (50 ~ 60Hz)
S8508
S8512
2000W AC power supply module: 100~240 VAC auto-ranging (50 ~ 60Hz) Output 1200W: 100 ~ 120 VAC Output 2000W: 200 ~ 240 VAC 2000W DC power supply module: -48 ~ -60 VDC 2000W < 1200W <1600W
Input Voltage (DC) Max Power Output of Single Power Module Max Power Dissipation Power Redundancy
Description
1+1 redundancy for PoE power supply modules Hot swappable 2500W AC power supply module: 100~240 VAC auto-ranging Output 1250W: 100 ~ 120 VAC Output 2500W: 200 ~ 240 VAC Totally 2500W: 200 ~ 240V Supports 144 ports at 15.4W
Description
2+1 redundancy for PoE power supply modules Hot swappable 2500W AC power supply module: 100 ~ 240 VAC auto-ranging Output 1200W: 100 ~ 120 VAC Output 2500W: 200 ~ 240 VAC Totally 4500W: 200 ~ 240V Supports 288 ports at 15.4W
S8502
12 12 3 144 144
S8505
20 20 5 240 240
S8508
32 32 8 384 384
S8512
48 48 12 576 576
Huawei Datacom
Quidway S8500 Series 10G Core Routing Switches
Description
Name
RFC1058 RFC1723 RIP RFC1724 RFC2453 RFC2083 RFC791 RFC792 RFC793 RFC768 RFC826 RFC783 RFC854 RFC894 RFC1213 RFC950 RFC959 RFC1141 RFC1122 RFC1256 IP General RFC1393 RFC 2338 RFC 2787
Code
RIPv1 RIPv2 RIPv2 MIB RIPv2
Description
PNG (Portable Network Graphics) specification version IP ICMP TCP UDP ARP TFTP Telnet IP over Ethernet MIB-II Internet standard subnetting procedure FTP Incremental updating of the Internet checksum Requirements for Internet hosts - communication layers ICMP router discovery messages Trace route using an IP option VRRP Definitions of Managed Objects for VRRP DHCP relay IGMP Snooping Routing Policy Specification Language (RPSL) NTPv3 Evolution of the interfaces group of MIB-II SNMP Telnet echo option Telnet suppress go ahead option NSFNET routing architecture NAT NAT terminology and considerations RADIUS HWTACACS
RFC 1542 & 2131 RFC2236 RFC2280 RFC1305 RFC1573 RFC1157 RFC857 RFC858 RFC1093 RFC1631 RFC2663 RFC2138 RFC1492
Huawei Datacom
Quidway S8500 Series 10G Core Routing Switches
Name
RFC 1112 RFC 2236 RFC 2715 IP Multicast RFC 2362 Draft RFC 3618 RFC 2283 RFC2474 QoS RFC2475 RFC3168 RFC3031 RFC3032 MPLS RFC3033 RFC3036 RFC3037 RFC2547 RFC2764 RFC2796 VPN RFC2842 RFC2858 RFC2917 RFC2918 RFC3107 Draft VLL&VPLS Draft Draft Draft RFC1619 PoS RFC1661 RFC1662 RFC2687 ITU
Code
IGMPv2
Description
Host extensions for IP multicasting Interoperability rules for multicast routing protocols PIM-SM PIM-DM:draft-ietf-idmr-pim-dm-06 MSDP Multi-protocol extensions for BGPv4 Definition of the Differentiated Service field (DS field) in the IPv4 and IPv6 headers Architecture for Differentiated Service The addition of Explicit Congestion Notification (ECN) to IP Multi-protocol label switching architecture MPLS label stack encoding The assignment of the information field and protocol identifier in the Q.2941 generic identifier and Q.2957 userto-user signaling for the Internet protocol LDP specification LDP applicability BGP/MPLS VPN A framework for IP based virtual private networks BGP route reflection - an alternative to full mesh IBGP Capabilities advertisement with BGPv4 Multi-protocol extensions for BGPv4 A core MPLS IP VPN architecture Route refresh capability for BGPv4 Carrying label information in BGPv4 Draft-martini-l2circuit-trans-mpls-08.txt Draft-martini-l2circuit-encap-mpls-04.txt Draft-kompella-ppvpn-l2vpn-01.txt Draft-ietf-l2vpn-vpls-ldp-06.txt PPP over SONET The point-to-point protocol PPP in HDLC-like framing PPP in a real-time oriented HDLC-like framing Definition and test methods for the relevant parameters of single-mode fibers Characteristics of a single-mode optical fiber cable
10
Name
Code
G.661 (11/96) G.662 (7/95) G.663 (10/96) G.671 (11/96)
Description
Definition and test methods for the relevant generic parameters of optical fiber amplifiers Generic characteristics of optical fiber amplifier devices and sub-systems Application related aspects of optical fiber amplifier devices and sub-systems Transmission characteristics of passive optical components Functional characteristics of interoffice and long-haul line systems using optical amplifiers, including optical multiplexing Physical/Electrical characteristics of hierarchical digital interfaces Optical interfaces for equipments and systems relating to the synchronous digital hierarchy Digital line systems based on the synchronous digital hierarchy for use on optical fiber cables Equipment engineering; environmental conditions and environment tests for telecommunications equipment Electromagnetic compatibility Dimensions of mechanical structures of the 482.6 mm series
ITU
ETS IEC
ETS 300 019-2 1999 IEC 1000 1995 IEC 297 1986
EN 55022: 1998 + A1: 2000 + A2: 2003 EN 55024: 1998+ A1: 2001 + A2: 2003 CISPR 22: 2003 CISPR 24: 1997+A1:2001+A2:2002 ETSI EN 300 386V1.3.2:2003 VCCI V-3: 2003.04 EMC AS/NZS CISPR 22 CNS 13438:1997 FCC part 15:2003 Class A EMC Directive 89/336/EEC R&TTE Directive 99/5/EC Article 3.1 (b) IECS-003 GB9254 EN 60950: 2000 EN 60825-1: 1993+A1:1997 Safety EN 60825-2: 2000 UL 60950-1: 2003, First Edition CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003 IEC 60950
11
Huawei Datacom
Quidway S8500 Series 10G Core Routing Switches
Name
RFC2401 RFC2402 RFC2403 RFC2404 RFC2405 IPSec RFC2406 RFC2407 RFC2408 RFC2409 RFC2410
Code
Description
Security architecture for the Internet protocol IP authentication header The use of HMAC-MD5-96 within ESP and AH The use of HMAC-SHA-1-96 within ESP and AH The ESP DES-CBC cipher algorithm with explicit IV IP Encapsulating Security Payload (ESP) The Internet IP security domain of interpretation for ISAKMP Internet Security Association and Key Management Protocol (ISAKMP) The Internet Key Exchange (IKE) The NULL encryption algorithm and its use with IPSec
Ordering Information
Users can purchase the chassis, power supplies and modules as actually required. Table 7 Order Inofrmation for S8502
Name Description
S8502 Ethernet switch chassis with fan, 1 AC power and documents S8502 Ethernet switch chassis with fan, 1 DC power and documents
Quantity
Remark
Chassis Configuration (Chassis with 1 AC or DC power) LS-8502-AC-OVS LS-8502-DC-OVS Power Supply Configuration LSBM9POWER LSBM5POWER Main Control Board LSBM1SRP1M0 Software LIS-Quidway-S8502-OVS S8502 VRP network operating system (host software) 1 Mandatory S8502 general main control unit with switching fabric 1-2 Mandatory S8502 AC power supply S8502 DC power supply 0-1 0-1 Optional Optional 1 1 Mandatory Mandatory
12
Quantity
Remark
Chassis Configuration (Chassis with 1 AC or DC power) LS-8505-AC-OVS LS-8505-DC-OVS Cabinet Configuration LS-8500-2.2m LS-8500-1.8m Power Supply Configuration LSBM7POWER LSBM2POWER Main Control Board LSBM1SRP1N2 LSBM1SRP1N3 Software LIS-Quidway-S8505-OVS S8505 VRP network operating system (host software) 1 Mandatory S8505 general main control unit with switching fabric S8505/08/12 general main control unit with switching fabric (clock) 1-2 1-2 Mandatory Mandatory S8505 AC P/S 90-264V (Max 1200W) S8505 DC P/S 36-75V (Max 1200W) 0-1 0-1 Optional Optional Switch router rack 2200 (H) Switch router rack 1800 (H) 0-1 0-1 Optional Optional 1 1 Mandatory Mandatory
Notes: SRP1N2 and SRP1N3 can not be mixed up for configuration. Only 2 SRP1N2 or 2 SRP1N3 are allowed to be deployed in one chassis. For more information, please check Quidway S8500 Series Switch Quick Configuration Manual V1.00.
Quantity
Remark
Chassis Configuration (Chassis with 1 AC or DC power) LS-8508-AC-OVS LS-8508-DC-OVS Cabinet Configuration LS-8500-2.2m LS-8500-1.8m Switch router rack 2200 (H) Switch Rrouter rack 1800 (H) 0-1 0-1 Optional Optional 1 1 Mandatory Mandatory
1
Huawei Datacom
Quidway S8500 Series 10G Core Routing Switches
Name
Power Supply Configuration LSBM8POWER LSBM4POWER Main Control Board LSBM1SRP1N1 LSBM1SRP1N3 Software LIS-Quidway-S8508-OVS
Description
S8512&S8508 AC P/S 90-264V (Max 2000W) S8512&S8508 DC P/S 36-75V (Max 2000W)
Quantity
0-1 0-1
Remark
Optional Optional
S8508 general main control unit with switching fabric S8505/08/12 general main control unit with switching fabric (clock)
1-2 1-2
Mandatory Mandatory
Mandatory
Notes: SRP1N1 and SRP1N3 can not be mixed up for configuration. Only 2 SRP1N1 or 2 SRP1N3 are allowed to be deployed in one chassis. For more information, please check Quidway S8500 Series Switch Quick Configuration Manual V1.00.
Quantity
Remark
Chassis Configuration (Chassis with 1 AC or DC power) LS-8512-AC-OVS LS-8512-DC-OVS Cabinet Configuration LS-8500-2.2m LS-8500-1.8m Power Supply Configuration LSBM8POWER LSBM4POWER Main Control Board LSBM1SRP1N0 LSBM1SRP1N3 Software LIS-Quidway-S8512-OVS 1 Mandatory 1-2 1-2 Mandatory Mandatory 0-1 0-1 Optional Optional 0-1 0-1 Optional Optional 1 1 Mandatory Mandatory
Notes: SRP1N0 and SRP1N3 can not be mixed up for configuration. Only 2 SRP1N0 or 2 SRP1N3 are allowed to be deployed in one chassis. For more information, please check Quidway S8500 Series Switch Quick Configuration Manual V1.00.
14
Description
Remarks
LSBM1FP20B0
0-3
0-5
0-8
0-12
Optional
LSBM1GP12B0
0-3
0-5
0-8
0-12
Optional
LSBM1GT12B0
0-3
0-5
0-8
0-12
Optional
LSBM1GT24B0
0-3
0-5
0-8
0-12
Optional
LSBM1GP24B0
0-3
0-5
0-8
0-12
Optional
LSBM1XK1B0
0-3
0-5
0-8
0-12
Optional
LSBM1XP2B0 LSBM1XP4B0
0-3 0-3
0-5 0-5
0-8 0-8
0-12 0-12
Optional Optional
LSBM1F32GB0
0-3
0-5
0-8
0-12
Optional
LSBM1GT8PB0
0-3
0-5
0-8
0-12
Optional
0-3
0-5
0-8
0-12
Optional
0-3
0-5
0-8
0-12
Optional
15
Huawei Datacom
Quidway S8500 Series 10G Core Routing Switches
Name
Description
S8500 20-port 100BASE-FX Interface Module, SFP Req. (Enhanced) S8500 12-port 1000BASE-X Interface Module, SFP Req. (Enhanced) S8500 12-port 10/100/1000BASE-T Interface Module, RJ45 (Enhanced) S8500 24-port 10/100/1000BASE-T Interface Module, RJ45 (Enhanced) S8500 24-port 1000BASE-X Interface Module, SFP Req. (Enhanced) S8500 1-port 10G Interface Module, XENPAK Req. (Enhanced) S8500 2-port 10G Interface Module, XFP Req. (Enhanced) S8500 4-port 10G Interface Module, XFP Req. (Enhanced) S8500 32-port 10/100BASETX RJ45 and 4-port 1000BASE-X SFP (Enhanced) S8500 8-port 10/100/1000BASE-T RE45 and 4-port 1000BASE-X SFP (Enhanced) S8500 4-port OC-3c (155M) PoS SFP and 8-port 1000BASE-X SFP (Enhanced) S8500 4-port OC-48c (2.5G) PoS Interface Module, SFP Req. (Enhanced) S8500 1-port OC-192c (10G) PoS Interface Module, XFP Req. (Enhanced)
NEW
Quantity S8502
0-3
S8505
0-5
S8508
0-8
S8512
0-12
Remarks
LSBM1FP20CA0
Optional
LSBM1GP12CA0
0-3
0-5
0-8
0-12
Optional
LSBM1GT12CA0
0-3
0-5
0-8
0-12
Optional
LSBM1GT24CA0
0-3
0-5
0-8
0-12
Optional
LSBM1GP24CA0
0-3
0-5
0-8
0-12
Optional
LSBM1XK1CA0
0-3
0-5
0-8
0-12
Optional
LSBM1XP2CA0 LSBM1XP4CA0
0-3 0-3
0-5 0-5
0-8 0-8
0-12 0-12
Optional Optional
LSBM1F32GCA0
0-3
0-5
0-8
0-12
Optional
LSBM1GT8PCA0
NEW
0-3
0-5
0-8
0-12
Optional
LSBM1P4G8CA0
0-3
0-5
0-8
0-12
Optional
LSBM1SP4CA0
0-3
0-5
0-8
0-12
Optional
LSBM1UP1CA0
0-3
0-5
0-8
0-12
Optional
LSBM1VP2CA0
0-3
0-5
0-8
0-12
Optional
16
Name
IPv6-ready Module LSBM1GV48DB0
Description
Remarks
0-3
0-5
0-8
0-12
Optional
LSBM1GP24DB LSBM1GP24DC
S8500 24-port 1000BASE-X Interface Module, SFP Req. S8500 24-port 1000BASE-X Interface Module, SFP Req. S8500 24-port 10/100/1000BASE-T Interface Module, RJ45
0-3 0-3
0-5 0-5
0-8 0-8
0-12 0-12
Optional Optional
NEW
NEW
0-3
0-5
0-8
0-12
Optional
S8500 48-port 10/100/1000BASE-T Interface Module, RJ45 (PoE ready) DIMM for PoE Master and Slave Power Management
0-3
0-5
0-6
0-6
0-3
0-5
0-6
0-6
S8500 NAT Service Interface Module (Standard) S8500 VPLS Service Interface Module (Standard)
NEW
0-1 0-1
0-1 0-1
0-1 0-1
0-1 0-1
Optional Optional
LSBM1FW8DB0
S8500 Firewall Service and 8-port 1000BASE-X Interface Module (Standard) S8500 IPSec Service and 8-port 1000BASE-X Interface Module (Standard)
0-3
0-5
0-8
0-12
Optional
LSBM1IPSEC8DB0
NEW
0-3
0-5
0-8
0-12
Optional
Notes: The figures listed above do not include Optics. For more information, please check the latest Huawei Price List.
Applications
The S8500 series switches can be deployed for converged services for enterprise campus and carriernetworks:
Deployment Scenario for S8500 Switches in Distribution and Core Layers of MAN
The S8500 switches provide a robust high performance 10G network platform as the distribution and core layers equipment of an IP MAN.
17
Huawei Datacom
Quidway S8500 Series 10G Core Routing Switches
NE5000E/NE80E
2.5G PoS
S8500 S8500 AR46
10 GE
Office Building
S8500
S8500
Enterprise Campus
MA5200
S3900
S3900
Figure 2 Deployment Scenario for S8500 Switches in Distribution and Core Layers of MAN
In carrier backbone networking environment requiring high reliability, security and expandability, the network core equipment comprises the NE80/40 core router and the S8500 switches. With flexibly choices from 5~12 service module slots, the S8500 switches are configured with dual main control units, dual switching units and multiple power supplies as redundant backup to avoid network interruption. The core equipment can be interconnected via 10GE or PoS interface. For Internet Service Provider (ISP), the service convergence MAN must offer value-added services such as VoD, video conference, IP voice, E-learning and telemedicine, etc. So it is necessary to subdivide the services and users to ensure the security when Ethernet is deployed as access network layer. In this scenario the MA5200 can serve as the access server and those access Ethernet switches such as S5600 can directly connect to it via the 10/100/1000M Ethernet interfaces, and the S8500 can be networked with the BAS (MA5200) to provide user access control, authentication and billing functions to carry out flexible user management.
18
Deployment Scenario for S8500 Switches with RPR Solution in Backbone Layer of
Campus Network
CERNET NE20/NE16
2.5G PoS
S3900 S3900 S3900 6502 S8500 S8500 S3900 6503 S3900 S3900
10 GE RPR
S8500 S8500 6506
Administration Building
Dormitory Building
Lecture Hall
S3900
S3900
S3900
Figure 3 Deployment Scenario for S8500 Switches with RPR Solution in Backbone Layer of Campus Network
The 10G RPR interface module can be used to deploy advanced, intelligent and resilient ring, offering campus network high speed L2 packet forwarding. Further more, due to advanced network design (inner ring and outer ring), the switchover time for link failure is less than 50 ms (carrier class level). In addition, the RPR can offer complete QoS mechanism, which guarantees the high priority service, such as data flow for administration purpose.
1
Huawei Datacom
Quidway S8500 Series 10G Core Routing Switches
10 GE
IP-Phone VLAN 1
S8500
Voice Gateway
Administrator Center
VLAN 2 S3900 Video Phone IP-Phone
Manufactoryl
Figure 4 Deployment Scenario for S8500 Switches in the Enterprise Backbone Network
The S8500 switches provide an ideal solution for enterprise backbone networks requirements for high reliability, expandability and service convergence. In this scenario, the S8500 switches act as the network core nodes to provide high speed connections to the ISP network for its powerful routing capacity and abundant L3 features. The S8500 switches can provide a full security management mechanism and QoS guarantee for the enterprise backbone network, and control the access authorities and users bandwidth flexibly. Supporting standard VLAN and multiple VLAN-based extended functions, the switches can isolate enterprise servers farm and avoid illegal access to the servers. Double 10GE links for redundant backup are provided in the networking core layer with two or more core switches.
20
Area 1
SecBlade S8500
Area 3
Area 2
Figure 5 Deployment Scenario for S8500 Series Firewall Application at the Egress
While located at the egress of the Internet, the SecBlade FW module can support NAT, ALGs of multiple application protocols such as FTP and H.323, and varieties of attack defending, thus ensuring normal secure access from the internal network to the external network.
21
Huawei Datacom
Quidway S8500 Series 10G Core Routing Switches
SecBlade FW module is located at the internal network for protecting important areas Important protection area 1 in the internal network
Secure_Vlan1
SecBlade S8500
Secure_Vlan2
Figure 6 Deployment Scenario for S8500 Series Firewall Application at the Internal Network
If there are important network segments in the internal network, the SecBlade FW module can be deployed in the internal network for protection. It configures Secure VLAN, formulates rules for each Secure VLAN, and customizes security strategies according to specific application features. This deployment can detect all traffic flows into or out of the protected network.
22
iMS
VPN Manager
iTellin/CAMS
IPSec
Stock User
IPSec
SecBlade-VPN S85
Ethernet VLAN Access
Enterprise
VLAN VPN L2TP
Securities Company
2
HUAWEI TECHNOLOGIES CO., LTD. Add: Huawei Industrial Base Bantian Longgang Shenzhen 518129, P.R.China Tel : +86-755-28780808 Version No: M3-080030-20060601-C-2.0 www.huawei.com