Powersim Inc. (Powersim) makes no representation or warranty with respect to the adequacy or accuracy of this documentation or the software which it describes. In no event will Powersim or its direct or indirect suppliers be liable for any damages whatsoever including, but not limited to, direct, indirect, incidental, or consequential damages of any character including, without limitation, loss of business profits, data, business information, or any and all other commercial damages or losses, or for any damages in excess of the list price for the licence to the software and documentation.

Powersim Inc. email: info@powersimtech.com http://www.powersimtech.com

-8

Contents
1 General Information
1.1 1.2 1.3 1.4 1.5 1.6 Introduction 1 Circuit Structure 2 Software/Hardware Requirement 3 Installing the Program 3 Simulating a Circuit 4 Component Parameter Specification and Format 4

Power Circuit Components


2.1 Resistor-Inductor-Capacitor Branches 7 2.1.1 Resistors, Inductors, and Capacitors 7 2.1.2 Rheostat 8 2.1.3 Saturable Inductor 9 2.1.4 Nonlinear Elements 10 2.2 Switches 11 2.2.1 Diode, DIAC, and Zener Diode 12 2.2.2 Thyristor and TRIAC 13 2.2.3 GTO, Transistors, and Bi-Directional Switch 15 2.2.4 Linear Switches 17 2.2.5 Switch Gating Block 19 2.2.6 Single-Phase Switch Modules 21 2.2.7 Three-Phase Switch Modules 22 2.3 2.4 Coupled Inductors 24 Transformers 26 2.4.1 Ideal Transformer 26

i -7

2.4.2 Single-Phase Transformers 26 2.4.3 Three-Phase Transformers 29 2.5 Magnetic Elements 30 2.5.1 Winding 30 2.5.2 Leakage Flux Path 31 2.5.3 Air Gap 32 2.5.4 Linear Core 34 2.5.5 Saturable Core 34 2.6 Other Elements 36 2.6.1 Operational Amplifier 36 2.6.2 dv/dt Block 37 2.6.3 Power Modeling Block 38 2.7 Thermal Module 39 2.7.1 2.7.2 2.7.3 2.7.4 2.7.5 2.7.6 2.7.7 2.8 2.8.1 2.8.2 2.8.3 2.8.4 2.8.5 2.8.6 2.8.7 2.8.8 2.8.9 2.9 2.10 Device Database Editor 39 Diode Device in the Database 48 Diode Loss Calculation 49 IGBT Device in the Database 51 IGBT Loss Calculation 53 MOSFET Device in the Database 56 MOSFET Loss Calculation 58 Reference Direction of Mechanical Systems 61 DC Machine 64 Induction Machine 66 Induction Machine with Saturation 70 Brushless DC Machine 72 Synchronous Machine with External Excitation 77 Permanent Magnet Synchronous Machine 80 Permanent Magnet Synchronous Machine with Saturation 83 Switched Reluctance Machine 87

Motor Drive Module 61

MagCoupler Module 90 MagCoupler-RT Module 95

-6 ii

2.11

Mechanical Elements and Sensors 98 2.11.1 Mechanical Elements and Sensors 98 2.11.1.1 Constant-Torque Load 98 2.11.1.2 Constant-Power Load 99 2.11.1.3 Constant-Speed Load 100 2.11.1.4 General-Type Load 100 2.11.1.5 Externally-Controlled Load 101 2.11.2 Gear Box 101 2.11.3 Mechanical Coupling Block 102 2.11.4 Mechanical-Electrical Interface Block 102 2.11.5 Speed/Torque Sensors 105 2.11.6 Position Sensors 107 2.11.6.1 Absolute Encoder 108 2.11.6.2 Incremental Encoder 108 2.11.6.3 Resolver 109 2.11.6.4 Hall-Effect Sensor 110

Control Circuit Components


3.1 Transfer Function Blocks 111 3.1.1 Proportional Controller 112 3.1.2 Integrator 113 3.1.3 Differentiator 115 3.1.4 Proportional-Integral Controller 115 3.1.5 Built-in Filter Blocks 116 3.2 Computational Function Blocks 117 3.2.1 Summer 117 3.2.2 Multiplier and Divider 118 3.2.3 Square-Root Block 118 3.2.4 Exponential/Power/Logarithmic Function Blocks 119 3.2.5 Root-Mean-Square Block 119 3.2.6 Absolute and Sign Function Blocks 120 3.2.7 Trigonometric Functions 120

iii-5

3.2.8 Fast Fourier Transform Block 121 3.3 Other Function Blocks 122 3.3.1 Comparator 122 3.3.2 Limiter 122 3.3.3 Gradient (dv/dt) Limiter 123 3.3.4 Trapezoidal and Square Blocks 123 3.3.5 Sampling/Hold Block 124 3.3.6 Round-Off Block 125 3.3.7 Time Delay Block 126 3.3.8 Multiplexer 127 3.3.9 THD Block 128 3.4 Logic Components 129 3.4.1 Logic Gates 129 3.4.2 Set-Reset Flip-Flop 130 3.4.3 J-K Flip-Flop 131 3.4.4 D Flip-Flop 131 3.4.5 Monostable Multivibrator 132 3.4.6 Pulse Width Counter 132 3.4.7 Up/Down Counter 133 3.4.8 A/D and D/A Converters 134 3.5 Digital Control Module 135 3.5.1 Zero-Order Hold 135 3.5.2 z-Domain Transfer Function Block 136 3.5.2.1 Integrator 138 3.5.2.2 Differentiator 139 3.5.2.3 Digital Filters 140 3.5.3 Unit Delay 143 3.5.4 Quantization Block 143 3.5.5 Circular Buffer 144 3.5.6 Convolution Block 145 3.5.7 Memory Read Block 146 3.5.8 Data Array 146 3.5.9 Stack 148

-4 iv

3.5.10 Multi-Rate Sampling System 148 3.6 SimCoupler Module 150 3.6.1 Set-up in PSIM and Simulink 150 3.6.2 Solver Type and Time Step Selection in Simulink 153

Other Components
4.1 4.2 Parameter File 157 Sources 158 4.2.1 Time 158 4.2.2 DC Source 158 4.2.3 Sinusoidal Source 159 4.2.4 Square-Wave Source 160 4.2.5 Triangular Source 161 4.2.6 Step Sources 162 4.2.7 Piecewise Linear Source 163 4.2.8 Random Source 165 4.2.9 Math Function Source 165 4.2.10 Voltage/Current-Controlled Sources 166 4.2.11 Nonlinear Voltage-Controlled Sources 168 4.3 4.4 4.5 4.6 Voltage/Current Sensors 169 Probes and Meters 169 Voltage/Current Scopes 172 Switch Controllers 174 4.6.1 On-Off Switch Controller 174 4.6.2 Alpha Controller 175 4.6.3 PWM Lookup Table Controller 176 4.7 Function Blocks 179 4.7.1 Control-Power Interface Block 179 4.7.2 ABC-DQO Transformation Block 180 4.7.3 Math Function Blocks 181

v -3

4.7.4 Lookup Tables 182 4.7.5 C Script Block 185 4.7.6 External DLL Blocks 186 4.7.7 Embedded Software Block 191

Analysis Specification
5.1 5.2 5.3 Transient Analysis 193 AC Analysis 194 Parameter Sweep 198

Circuit Schematic Design


6.1 6.2 6.3 6.4 Creating a Circuit 202 Editing a Circuit 203 Saving a File 206 Subcircuit 207 6.4.1 Creating Subcircuit - In the Main Circuit 208 6.4.2 Creating Subcircuit - Inside the Subcircuit 208 6.4.3 Connecting Subcircuit - In the Main Circuit 210 6.4.4 Other Features of the Subcircuit 210 6.4.4.1 Passing Variables from the Main Circuit to Subcircuit 211 6.4.4.2 Customizing the Subcircuit Image 212 6.4.4.3 Including Subcircuits in the PSIM Element List 213 6.5 6.6 6.7 Running the Simulation 214 Managing the PSIM Library 218 Other Options 223 6.7.1 Generate and View the Netlist File 223 6.7.2 Set Path 223 6.7.3 Settings 224 6.7.4 Printing the Circuit Schematic 224

-2 vi

Waveform Processing
7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 File Menu 226 Edit Menu 226 Axis Menu 227 Screen Menu 228 View Menu 230 Option Menu 231 Label Menu 231 Exporting Data 231

Error/Warning Messages and Other Simulation Issues


8.1 Simulation Issues 233 8.1.1 Time Step Selection 233 8.1.2 Propagation Delays in Logic Circuits 233 8.1.3 Interface Between Power and Control Circuits 234 8.1.4 FFT Analysis 234 8.2 8.3 Error/Warning Messages 235 Debugging 236

vii -1

0viii

1
General Information
1.1 Introduction
PSIM is a simulation software specifically designed for power electronics and motor drives. With fast simulation and friendly user interface, PSIM provides a powerful simulation environment for power electronics, analog and digital control, magnetics, and motor drive system studies. This manual covers both PSIM1 and the following add-on Modules: Motor Drive Module Digital Control Module SimCoupler Module Thermal Module MagCoupler Module MagCoupler-RT Module The Motor Drive Module has built-in machine models and mechanical load models for motor drive system studies. The Digital Control Module provides discrete elements such as zero-order hold, zdomain transfer function blocks, quantization blocks, digital filters, for digital control system analysis. The SimCoupler Module provides interface between PSIM and Matlab/Simulink2 for co-simulation. The Thermal Module provides the capability to calculate semiconductor devices losses. The MagCoupler Module provides interface between PSIM and the electromagnetic field analysis software JMAG3 for co-simulation. The MagCoupler-RT Module links PSIM with JMAG-RT3 data files. In addition, PSIM supports links to third-party software through custom DLL blocks. The overall PSIM environment is shown below.
1. PSIM and SIMVIEW are copyright by Powersim Inc., 2001-2006 2. Matlab and Simulink are registered trademarks of the MathWorks, Inc. 3. JMAG and JMAG-RT are copyright by the Japan Research Institute, Ltd., 1997-2006

Introduction

Third-party Software Matlab/Simulink - Control systems

PSIM
- Power electronics - Analog/digital control - Motor drives JMAG / JMAG-RT - Finite element analysis - Electric machines, and other magnetic devices

The PSIM simulation environment consists of the circuit schematic program PSIM, the simulator engine, and the waveform processing program SIMVIEW1. The simulation process is illustrated as follows.
PSIM Schematic Circuit Schematic Editor (input: *.sch)

PSIM Simulator

PSIM Simulator (output: *.smv or *.txt)

SIMVIEW

Waveform Processor (input: *.smv or *.txt)

Chapter 1 of this manual describes the circuit structure, software/hardware requirement, and parameter specification format. Chapter 2 through 4 describe the power and control circuit components. Chapter 5 describes the specifications of the transient analysis and ac analysis. The use of the PSIM schematic program and SIMVIEW is discussed in Chapter 6 and 7. Finally, error/warning messages are discussed in Chapter 8.

1.2

Circuit Structure
A circuit is represented in PSIM in four blocks: power circuit, control circuit, sensors, and switch controllers. The figure below shows the relationship between these blocks.

General Information

Power Circuit

Switch Controllers

Sensors

Control Circuit

The power circuit consists of switching devices, RLC branches, transformers, and coupled inductors. The control circuit is represented in block diagram. Components in s domain and z domain, logic components (such as logic gates and flip flops), and nonlinear components (such as multipliers and dividers) are used in the control circuit. Sensors are used to measure power circuit quantities and pass them to the control circuit. Gating signals are then generated from the control circuit and sent back to the power circuit through switch controllers to control switches.

1.3

Software/Hardware Requirement
PSIM runs in Microsoft Windows environment 2000/XP on personal computers. The minimum RAM memory requirement is 128 MB.

1.4

Installing the Program


A quick installation guide is provided in the flier PSIM - Quick Guide and on the CDROM. Some of the files in the PSIM directory are shown in the table below. Files PSIM.exe SIMVIEW.exe PcdEditor.exe s2z_converter.exe Description PSIM circuit schematic editor Waveform display program SIMVIEW Device database editor s-domain to z-domain converter

Software/Hardware Requirement

SetSimPath.exe psim.lib, psimimage.lib File extensions used in PSIM are: *.sch *.txt *.fra *.dev *.smv

Program to set up the SimCoupler Module PSIM library files

PSIM schematic file PSIM simulation output file (text) PSIM ac analysis output file (text) Device database file SIMVIEW data file

1.5

Simulating a Circuit
To simulate the sample one-quadrant chopper circuit chop.sch: - Start PSIM. From the File menu, choose Open to load the file chop.sch. - From the Simulate menu, choose Run PSIM to start the simulation. Simulation results will be saved to File chop.txt. - If the option Auto-run SIMVIEW is not selected in the Options menu, from the Simulate menu, choose Run SIMVIEW to start SIMVIEW. If the option is selected, SIMVIEW will be launched automatically. In SIMVIEW, select curves for display.

1.6

Component Parameter Specification and Format


The parameter dialog window of each component in PSIM has three tabs: Parameters, Other Info, and Color, as shown below.

The parameters in the Parameters tab are used in the simulation. The information in the

General Information

Other Info tab, on the other hand, is not used in the simulation. It is for reporting purposes only and will appear in the parts list in View -> Element List in PSIM. Information such as device rating, manufacturer, and part number can be stored under the Other Info tab. The component color can be set in the Color tab. Parameters under the Parameters tab can be a numerical value or a mathematical expression. A resistance, for example, can be specified in one of the following ways: 12.5 12.5k 12.5Ohm 12.5kOhm 25./2.Ohm R1+R2 R1*0.5+(Vo+0.7)/Io where R1, R2, Vo, and Io are symbols defined either in a parameter file (see Section 4.1), or in a main circuit if this resistor is in a subcircuit (see Section 6.3.4.1). Power-of-ten suffix letters are allowed in PSIM. The following suffix letters are supported: G M k or K m u n p 109 106 103 10-3 10-6 10-9 10-12

A mathematical expression can contain brackets and is not case sensitive. The following mathematical functions are allowed: + * / ^ SQRT SIN COS addition subtraction multiplication division to the power of [Example: 2^3 = 2*2*2] square-root function sine function cosine function

Component Parameter Specification and Format

ASIN ACOS TAN ATAN ATAN2 SINH COSH EXP LOG LOG10 ABS SIGN

sine inverse function cosine inverse function tangent function inverse tangent function inverse tangent function [- <= atan2(y,x) <= ] hyperbolic sine function hyperbolic cosine function exponential (base e) [Example: EXP(x) = ex] logarithmic function (base e) [Example: LOG(x) = ln (x)] logarithmic function (base 10) absolute function sign function [Example: SIGN(1.2) = 1; SIGN(-1.2)=-1]

General Information

2
Power Circuit Components
2.1 Resistor-Inductor-Capacitor Branches

2.1.1 Resistors, Inductors, and Capacitors


Both individual resistor, inductor, capacitor, and lumped RLC branches are provided in PSIM. Initial conditions of inductor currents and capacitor voltages can be defined. To facilitate the setup of three-phase circuits, symmetrical three-phase RLC branches, R3, RL3, RC3, RLC3, are provided. Initial inductor currents and capacitor voltages of the three-phase branches are all zero. Images:
R L C RL RC LC

R3 RLC

RL3

RC3

RLC3

For three-phase branches, the phase with a dot is Phase A. Attributes: Parameters Resistance Inductance Capacitance Initial Current Initial Cap. Voltage Description Resistance, in Ohm Inductance, in H Capacitance, in F Initial inductor current, in A Initial capacitor voltage, in V

Resistor-Inductor-Capacitor Branches

Current Flag

Flag for branch current output. If the flag is zero, there is no current output. If the flag is 1, the current will be available for display in the runtime graphs (under Simulate -> Runtime Graphs). It will also be saved to the output file for display in SIMVIEW. The current is positive when it flows into the dotted terminal of the branch.

Current Flag_A; Current Flag_B; Current Flag_C

Current flags for Phase A, B, and C of three-phase branches, respectively.

The resistance, inductance, or capacitance of a branch can not be all zero. At least one of the parameters has to be a non-zero value.

2.1.2 Rheostat
A rheostat is a resistor with a tap. Image:
t k m

Attributes: Parameters Total Resistance Tap Position (0 to 1) Current Flag Description Total resistance of the rheostat R (between Node k and m), in Ohm The tap position Tap. The resistance between Node k and t is: R*Tap. Flag for the current that flows into Node k.

Power Circuit Components

2.1.3 Saturable Inductor


A saturable inductor takes into account the saturation effect of the magnetic core. Image:

Attributes: Parameters Current v.s. Inductance Current Flag Description Characteristics of the current versus the inductance (i1, L1), (i2, L2), etc. Flag for the current display

The nonlinear B-H curve is represented by piecewise linear approximation. Since the flux density B is proportional to the flux linkage and the magnetizing force H is proportional to the current i, the B-H curve can be represented by the -i curve instead, as shown below.
3 2 1 (B)
Inductance L = / i

i1

i2

i3

i (H)

The inductance is defined as: L = / i, the ratio of v.s. i at each point. The saturation characteristics are defined by a series of data points as: (i1, L1), (i2, L2), (i3, L3), etc. Note that the defined saturation characteristics must be such that the flux linkage is monotonically increasing. That is, L1*i1 < L2*i2 < L3*i3, etc. Also, similar to the saturation characteristics in the real world, the slope of each linear segment must be monotonically decreasing as the current increases. In certain situations, circuits that contain saturable inductors may fail to converge. Connecting a very small capacitor across the saturable inductor may help the convergence.

Resistor-Inductor-Capacitor Branches

2.1.4 Nonlinear Elements


The following elements with nonlinear voltage-current relationship are provided: - Resistance-type [v = f(i)] - Resistance-type with additional input x [v = f(i,x)] - Conductance-type [i = f(v)] - Conductance-type with additional input x [i = f(v,x)] The additional input x must be a voltage signal. Images:
Nonlinear element Nonlinear element (with additional input)

Input x

Attributes: For resistance-type elements: Parameters Expression f(i) or f(i,x) Expression df/di Initial Value io Lower Limit of i Upper Limit of i Description Expression of v in terms of i and x [v = f(i) or v = f(i,x)] The derivative of the voltage v versus current i, i.e. df(i)/di The initial value of the current i The lower limit of the current i The upper limit of the current i

For conductance-type elements: Parameters Expression f(v) or f(v,x) Expression df/dv Initial Value vo Lower Limit of v Upper Limit of v Description Expression of i in terms of v and x [i = f(v) or i = f(v,x)] Derivative of the current i versus voltage v, i.e. df(v)/dv The initial value of the voltage v The lower limit of the voltage v The upper limit of the voltage v

10

Power Circuit Components

A good initial value and lower/upper limits will help the convergence of the solution. Example: Nonlinear Diode

The nonlinear element (NONI) in the circuit above models a nonlinear diode. The diode current is expressed as a function of the voltage as: i = 10-14 * (e 40*v-1). In PSIM, the specifications of the nonlinear element will be: Expression f(v) Expression df/dv Initial Value vo Lower Limit of v Upper Limit of v 1e-14*(EXP(40*v)-1) 40e-14*EXP(40*v) 0 -1e3 1

2.2

Switches
There are two basic types of switches in PSIM. One is the switchmode type. It operates either in the cut-off region (off state) or saturation region (on state). The other is the linear type. It can operates in either cut-off, linear, or saturation region. Switches in switchmode include the following: - Diode and DIAC - Thyristor and TRIAC - Self-commutated switches, specifically: - Gate-Turn-Off switch - npn bipolar junction transistor - pnp bipolar junction transistor - Insulated-Gate Bipolar Transistor (IGBT) - n-channel Metal-Oxide-Semiconductor Field-Effect Transistor (MOSFET) and p-channel MOSFET - Bi-directional switch

Switches

11

Switch models are ideal. That is, both turn-on and turn-off transients are neglected. A switch has an on-resistance of 10 and an off-resistance of 10M. Snubber circuits are not required for switches. Linear switches include the following: - npn bipolar junction transistor - pnp bipolar junction transistor

2.2.1 Diode, DIAC, and Zener Diode


The conduction of a diode is determined by circuit operating conditions. A diode is turned on when it is positively biased, and is turned off when the current drops to zero. Image:

Attributes: Parameters Diode Voltage Drop Initial Position Current Flag Description Diode conduction voltage drop, in V Flag for the initial diode position. If the flag is 0, the diode is off. If it is 1, the diode is on. Current flag of the diode.

A DIAC is a bi-directional diode. A DIAC does not conduct until the breakover voltage is reached. After that, the DIAC goes into avalanche conduction, and the conduction voltage drop is the breakback voltage. Image:

Attributes: Parameters Breakover Voltage Description Voltage at which breakover occurs and the DIAC begins to conduct, in V

12

Power Circuit Components

Breakback Voltage Current Flag

Conduction voltage drop, in V Current flag

A zener diode is modelled by a circuit as shown below. Images:


Zener
K K

Circuit Model

VB A A

Attributes: Parameters Breakdown Voltage Forward Voltage Drop Current Flag Description Breakdown voltage VB of the zener diode, in V Voltage drop of the forward conduction (diode voltage drop from anode to cathode), in V Flag for zener current output (from anode to cathode)

When the zener diode is positively biased, it behaviors as a regular diode. When it is reverse biased, it will block the conduction as long as the cathode-anode voltage VKA is less than the breakdown voltage VB. When VKA exceeds VB, the voltage VKA will be clamped to VB. [Note: when the zener is clamped, since the diode is modelled with an on-resistance of 10, the cathode-anode voltage will in fact be equal to: VKA = VB + 10 * IKA. Therefore, depending on the value of IKA, VKA will be slightly higher than VB. If IKA is very large, VKA can be substantially higher than VB].

2.2.2 Thyristor and TRIAC


A thyristor is controlled at turn-on. The turn-off is determined by circuit conditions. A TRIAC is a device that can conduct current in both directions. It behaviors in the same way as two opposite thyristors connected in parallel.

Switches

13

Images:
Thyristor
A K Gate Gate

TRIAC

Attributes: Parameters Voltage Drop Holding Current Latching Current Description Thyristor conduction voltage drop, in V Minimum conduction current below which the device stops conducting and returns to the OFF state (for thyristor only) Minimum ON state current required to keep the device in the ON state after the triggering pulse is removed (for thyristor only) Flag for the initial switch position (for thyristor only) Flag for switch current output

Initial Position Current Flag

Note that for the TRIAC device, the holding current and latching current are set to zero. There are two ways to control a thyristor or TRIAC. One is to use a gating block, and the other is to use a switch controller. The gate node of a thyristor or TRIAC must be connected to either a gating block or a switch controller. The following examples illustrate the control of a thyristor switch. Examples: Control of a Thyristor Switch
Gating Block

Alpha Controller

14

Power Circuit Components

This circuit on the left uses a switching gating block. The switching gating pattern and the frequency are pre-defined, and remain unchanged throughout the simulation. The circuit on the right uses an alpha switch controller. The delay angle alpha, in deg., is specified through the dc source in the circuit.

2.2.3 GTO, Transistors, and Bi-Directional Switch


Self-commutated switches in the switchmode, except pnp bipolar junction transistor (BJT) and p-channel MOSFET, are turned on when the gating signal is high (when a voltage of 1V or higher is applied to the gate node) and the switch is positively biased (collector-emitter or drain-source voltage is positive). It is turned off whenever the gating signal is low or the current drops to zero. For pnp BJT and p-channel MOSFET, switches are turned on when the gating signal is low and switches are negatively biased (collector-emitter or drain-source voltage is negative). A GTO switch is a symmetrical device with both forward-blocking and reverse-blocking capabilities. An IGBT or MOSFET switch consist of an active switch with an antiparallel diode. A bi-directional switch conducts currents in both directions. It is on when the gating signal is high and is off when the gating signal is low, regardless of the voltage bias conditions. Note that a limitation of the BJT switch model in PSIM, in contrary to the device behavior in the real life, is that a BJT switch in PSIM will block reverse voltage (in this sense, it behaviors like a GTO). Also, it is controlled by a voltage signal at the gate node, not a current. Images:
GTO BJT( (npn) BJT (pnp) MOSFET (n-channel) MOSFET (p-channel) IGBT Bi-directional switch

Switches

15

Attributes: Parameters Initial Position Current Flag Description Initial switch position flag. For MOSFET and IGBT, this flag is for the active switch, not for the anti-parallel diode. Switch current flag. For MOSFET and IGBT, the current through the whole module (the active switch plus the diode) will be displayed.

A switch can be controlled by either a gating block or a switch controller. They must be connected to the gate (base) node of the switch. The following examples illustrate the control of a MOSFET switch. Examples: Control of a MOSFET Switch

On-off Controller

The circuit on the left uses a gating block, and the one on the right uses an on-off switch controller. The gating signal is determined by the comparator output. Example: Control of a npn Bipolar Junction Transistor The circuit on the left uses a gating block, and the one on the right uses an on-off switch controller.

16

Power Circuit Components

The following shows another example of controlling the BJT switch. The circuit on the left shows how a BJT switch is controlled in the real life. In this case, the gating voltage VB is applied to the transistor base drive circuit through a transformer, and the base current determines the conduction state of the transistor. This circuit can be modelled and implemented in PSIM as shown on the right. A diode, Dbe, with a conduction voltage drop of 0.7V, is used to model the pn junction between the base and the emitter. When the base current exceeds 0 (or a certain threshold value, in which case the base current will be compared to a dc source), the comparator output will be 1, applying the turn-on pulse to the transistor through the on-off switch controller.

2.2.4 Linear Switches


Linear switches include npn bipolar junction transistor and pnp bipolar junction transistor. They can operate in either cut-off, linear, or saturation region. Images:
BJT (npn) BJT (pnp)

Switches

17

Attributes: Parameters Current Gain beta Bias Voltage Vr Description Transistor current gain , defined as: =Ic/Ib Forward bias voltage, in V, between base and emitter for the npn transistor, or between emitter and base for the pnp transistor. Saturation voltage, in V, between collector and emitter for the npn transistor, and between emitter and collector for the pnp transistor.

Vce,sat [or Vec,sat for pnp]

A linear BJT switch is controlled by the base current Ib. It can operate in one of the three regions: cut-off (off state), linear, and saturation region (on state). The properties of these regions for the npn transistor are: Ic = 0 - Cut-off region: Vbe < Vr; Ib = 0; - Linear region: Vbe = Vr; Ic = Ib; Vce > Vce,sat - Saturation region: Vbe = Vr; Ic < Ib; Vce = Vce,sat where Vbe is the base-emitter voltage, Vce is the collector-emitter voltage, and Ic is the collector current. Note that for both the npn and pnp transistors, the gate node (base node) is a power node, and must be connected to a power circuit component (such as a resistor or a source). It can not be connected to a gating block or a switch controller.
WARNING: It has been found that the linear model for npn and pnp

transistors works well in simple circuits, but may not work when circuits are complex. Please use this model with caution. Examples: Circuits Using the Linear BJT Switch Examples below illustrate the use of linear switches. The circuit on the left is a linear voltage regulator circuit, and the transistor operates in the linear mode. The circuit on the right is a simple test circuit.

18

Power Circuit Components

NPN_1

NPN_1

2.2.5 Switch Gating Block


A switch gating block defines the gating pattern of a switch or a switch module. The gating pattern can be specified either directly (the element is called Gating Block in the library) or in a text file (the element is called Gating Block (1) in the library). Note that a switch gating block can be connected to the gate node of a switch ONLY. It can not be connected to any other elements. Image:

Attributes: Parameters Frequency No. of Points Switching Points File for Gating Table Description Operating frequency of the switch or switch module connected to the gating block, in Hz Number of switching points (for the Gating Block element only) Switching points, in deg. If the frequency is zero, the switching points is in second. (for the Gating Block element only) Name of the file that stores the gating table (for the Gating Block (1) element only)

The number of switching points is defined as the total number of switching actions in one period. Each turn-on or turn-off action is counted as one switching point. For example, if a switch is turned on and off once in one cycle, the number of switching points will be 2.

Switches

19

For the Gating Block (1) element, the file for the gating table must be in the same directory as the schematic file. The gating table file has the following format: n G1 G2 ... ... Gn where G1, G2, ..., Gn are the switching points. Example: Assume that a switch operates at 2000 Hz and has the following gating pattern in one period:
35 92 175 187 345 357

180

360

(deg.)

The specification of the Gating Block element for this switch will be: Frequency No. of Points Switching Points 2000. 6 35. 92. 175. 187. 345. 357.

The gating pattern has 6 switching points (3 pulses). The corresponding switching angles are 35o, 92o, 175o, 187o, 345o, and 357o, respectively. If the Gating Block (1) element is used instead, the specification will be: Frequency File for Gating Table 2000. test.tbl

The file test.tbl will contain the following: 6 35. 92. 175. 187.

20

Power Circuit Components

345. 357.

2.2.6 Single-Phase Switch Modules


Built-in single-phase diode bridge module and thyristor bridge module are provided. The images and internal connections of the modules are shown below. Images:
Diode bridge
A+ DC+
A+ A1 3 DC+

Thyristor bridge
A+ DC+ A+ ADCCt 4 2 DC1 Ct 3 DC+

A-

DC-

2 DC-

A-

Attributes: Parameters Diode Voltage Drop or Voltage Drop Init. Position_i Current Flag_i Description Forward voltage drop of each diode or thyristor, in V Initial position for Switch i Current flag for Switch i

Node Ct at the bottom of the thyristor module is the gating control node for Switch 1. For the thyristor module, only the gating signal for Switch 1 needs to be specified. The gating signals for other switches will be derived internally in the program. Similar to the single thyristor switch, a thyristor bridge can also be controlled by either a gating block or an alpha controller, as shown in the following examples. Examples: Control of a Thyristor Bridge The gating signal for the circuit on the left is specified through a gating block, and the gating signal for the circuit on the right is provided through an alpha controller. A major advantage of the alpha controller is that the delay angle alpha of the thyristor bridge, in deg., can be directly controlled.

Switches

21

2.2.7 Three-Phase Switch Modules


The following figure shows three-phase switch modules and the internal circuit connections. A three-phase voltage source inverter module VSI3 consists of either MOSFET-type or IGBT-type switches. A current source inverter module CSI3 consists of GTO-type switches, or equivalently IGBT in series with diodes. Images:
Diode full-wave
A B C DC+ A B C DC-

Thyristor full-wave
1 3 5
DC+ A B DC+ A B C DCCt

DC+

Ct

2
DC-

2
DC-

Thyristor half-wave (3-phase)


A B C Ct N B C A

Thyristor half-wave
Ct A1 N N

1 2

Ct

1 2 3

A6 Ct

22

Power Circuit Components

VSI3
DC+ DC+ A B DCCt DCC

VSI3 (MOSFET switches)


1 3 5
A B C

Ct

CSI3
DC+ DC+

CSI3
A B
Ct

5
A B C

DCCt

C
DC-

Attributes: Parameters On-Resistance Saturation Voltage Voltage Drop Diode Voltage Drop Init. Position_i Current Flag_i Description On resistance of the MOSFET switch during the on state, in Ohm (for MOSFET-type switches only) Conduction voltage drop of the IGBT switch, in V (for IGBT-type switches only) Conduction voltage drop of the switch, in V (for CSI3 only) Conduction voltage drop of the anti-parallel diode, in V (for VSI3 only) Initial position for Switch i Current flag for Switch i

Similar to single-phase modules, only the gating signal for Switch 1 need to be specified for three-phase modules. Gating signals for other switches will be automatically derived. For the 3-phase half-wave thyristor bridge, the phase shift between two consecutive switches is 120o. For all other bridges, the phase shift is 60o. Thyristor bridges can be controlled by an alpha controller. Similarly, voltage/current

Switches

23

source inverters can be controlled by a PWM lookup table controller. The following examples illustrate the control of three-phase thyristor and voltage source inverter modules. Example: Control of Three-Phase Thyristor and VSI Modules

Vac

PWM Controller

The thyristor circuit on the left uses an alpha controller. For a three-phase circuit, the zero-crossing of the voltage Vac corresponds to the moment when the delay angle alpha is equal to zero. This signal is used to provide synchronization to the controller. The circuit on the right uses a PWM lookup table controller. The PWM patterns are stored in a lookup table in a text file. The gating pattern is selected based on the modulation index. Other inputs of the PWM lookup table controller include the delay angle, the synchronization, and the enable/disable signal. A detailed description of the PWM lookup table controller is given in the Switch Controllers section.

2.3

Coupled Inductors
Coupled inductors with two, three, and four branches are provided. Images:
2-branch 3-branch 4-branch

24

Power Circuit Components

Attributes: Parameters Lii (self) Lij (mutual) ii_initial Iflag_i Description Self inductance of the inductor i, in H Mutual inductance between Inductor i and j, in H Initial current in Inductor i Flag for the current printout in Inductor i

In the images, the circle, square, triangle, and plus marks refer to Inductor 1, 2, 3, and 4, respectively. The following shows a coupled inductor with two branches.
i1 + v1 -

i2

v2

Let L11 and L22 be the self-inductances of Branch 1 and 2, and L12 and L21 the mutual inductances, the branch voltages and currents have the following relationship:
v1 v2 = L 11 L 12 L 21 L 22 d i ---- 1 dt i 2

The mutual inductances between two windings are assumed to be always equal, i.e., L12 = L21. Example: Two mutually coupled inductors have the self inductances and mutual inductance as: L11 = 1 mH, L22 = 1.1 mH, and L12 = L21 = 0.9 mH. The specification of this element will be: L11 (self) L12 (mutual) L22 (self) 1m 0.9m 1.1m

Coupled Inductors

25

2.4

Transformers

2.4.1 Ideal Transformer


An ideal transformer has no losses and no leakage flux. Images:

Np

Ns

Np

Ns

The winding with the larger dot is the primary, and the other winding is the secondary. Attributes: Parameters Np (primary) Ns (secondary) Description No. of turns of the primary winding No. of turns of the secondary winding

Since the turns ratio is equal to the ratio of the rated voltages, the number of turns can be replaced by the rated voltage at each side.

2.4.2 Single-Phase Transformers


The following single-phase transformer modules are provided: - Transformer with 1 primary and 1 secondary windings - Transformer with 1 primary and 2 secondary windings - Transformer with 2 primary and 2 secondary windings - Transformer with 1 primary and 4 secondary windings - Transformer with 2 primary and 4 secondary windings - Transformer with 1 primary and 6 secondary windings - Transformer with 2 primary and 6 secondary windings

26

Power Circuit Components

Images:
2-winding p 3-winding s t p s_4 2-windinge p s 5-winding s_1 p_1 p_2 s_3 4-winding p_1 p_2 s_1 s_2 s_6 s_6 5-winding s_1 p_1 p_2 s_4 p p_2 6-winding s_1 7-winding s_1 s_2 p_1 8-winding s_1 s_2

In the images, p refers to primary, s refers to secondary, and t refers to tertiary. The winding with the largest dot is the primary winding or first primary winding. For the multiple winding transformers, the sequence of the windings is from the top to the bottom. For the transformers with 2 or 3 windings, the attributes are as follows. Attributes: Parameters Rp (primary); Rs (secondary); Rt (tertiary) Lp (pri. leakage); Ls (sec. leakage); Lt (ter. leakage) Lm (magnetizing) Np (primary); Ns (secondary); Nt (tertiary) Description Resistance of the primary/secondary/tertiary winding, in Ohm Leakage inductance of the primary/secondary/tertiary winding, in H (seen from the primary) Magnetizing inductance, in H No. of turns of the primary/secondary/tertiary winding

Transformers

27

All the resistances and inductances are referred to the primary winding side. If there are multiple primary windings, they are referred to the first primary winding side. For the transformers with more than 1 primary winding or more than 3 secondary windings, the attributes are as follows. Attributes: Parameters Rp_i (primary i); Rs_i (secondary i) Lp_i (pri. i leakage); Ls_i (sec. i leakage) Lm (magnetizing) Np_i (primary i); Ns_i (secondary i) Description Resistance of the ith primary/secondary/tertiary winding, in Ohm Leakage inductance of the ith primary/secondary/tertiary winding, in H (referred to the first primary winding) Magnetizing inductance, in H (seen from the first primary winding) No. of turns of the ith primary/secondary/tertiary winding

All the resistances and inductances are referred to the first primary winding side. Modeling of a Transformer: A transformer is modeled as coupled inductors. For example, a single-phase twowinding transformer is modeled as two coupled inductors. The equivalent circuit can be shown as:
Rp Primary Lp Rs Ls Np : Ns Secondary
Ideal

Lm

In the circuit, Rp and Rs are the primary and secondary winding resistances; Lp and Ls are the primary and secondary winding leakage inductances; and Lm is the magnetizing inductance. All the values are referred to the primary side. Example: A single-phase two-winding transformer has a winding resistance of 0.002 Ohm and leakage inductance of 1 mH at both the primary and the secondary side (all the values are referred to the primary). The magnetizing inductance is 100 mH, and the turns ratio

28

Power Circuit Components

is Np:Ns = 220:440. The transformer will be specified as: Rp (primary) Rs (secondary) Lp (primary) Ls (secondary) Lm (magnetizing) Np (primary) Ns (secondary) 2m 2m 1m 1m 100m 220 440

2.4.3 Three-Phase Transformers


Two-winding and three-winding transformer modules are provided, as shown below. They all have 3-leg cores. - 3-phase transformer (windings unconnected) - 3-phase Y/Y and Y/ connected transformer - 3-phase 3-winding transformer (windings unconnected) - 3-phase 3-winding Y/Y/ and Y// connected transformer - 3-phase 4-winding transformer (windings unconnected) Images:
Y/Y
A B C N n n a b c aa bb cc N A B C N a b c A B C N

Y/D
a b c A B C

D/D
a b c

2-winding (unconnected)
A+ AB+ BC+ Ca+ ab+ bc+ c-

Y/Y/D
A B C

Y/D/D

3-winding (unconnected)
a A+ b Ac B+ Baa C+ bb Ccc aa+ bb+ cc+ aa- bb- cca+ ab+ bc+ c-

4-winding (unconnected)
A+ AB+ BC+ CAA+ AABB+ BBCC+ CCa+ ab+ bc+ caa+ aabb+ bbcc+ cc-

Transformers

29

Attributes: Parameters Rp (primary); Rs (secondary); Rt (tertiary) Lp (pri. leakage); Ls (sec. leakage); Lt (ter. leakage) Lm (magnetizing) Np (primary); Ns (secondary); Nt (tertiary) Description Resistance of the primary/secondary/tertiary winding, in Ohm

Leakage inductance of the primary/secondary/tertiary winding, in H

Magnetizing inductance, in H (seen from the primary side) No. of turns of the primary/secondary/tertiary winding

In the images, P refers to primary, S refers to secondary, and T refers to tertiary. All resistances and inductances are referred to the primary or the first primary winding side. Three-phase transformers are modeled in the same way as single-phase transformers.

2.5

Magnetic Elements
A set of magnetic elements, including winding, leakage flux path, air gap, linear core, and saturable core, is provided to model magnetic devices. These elements are the basic building blocks of magnetic equivalent circuits, and they provide a very powerful and convenient way of modeling any types of magnetic devices.

2.5.1 Winding
A winding element provides the interface between the electric circuit and the magnetic equivalent circuit. Image:
E1 M1

E2

M2

30

Power Circuit Components

Attributes: Parameters Number of Turns Winding Resistance Description No. of turns of the winding Winding resistance, in Ohm

This element represents a winding on a magnetic core. The two electric nodes (E1 and E2) are connected to an electric circuit, while the two magnetic nodes (M1 and M2) are connected to other magnetic elements (such as leakage flux path, air gap, and magnetic core).

2.5.2 Leakage Flux Path


This element models the flow path of the leakage flux. Image:
M1 M2

Attributes: Parameters Inductance Factor AL Resistance for Losses Current Flag Description Inductance factor AL, defined as the inductance per turn squared Resistance R, in Ohm, that represents the losses due to the leakage flux. Display flag of the current that flows through the resistor R

The resistance R represents the losses due to the leakage flux. Assuming that the mmf (magnetomotive force) applied across the leakage flux path is F, the electric equivalent circuit of the leakage flux path is as follows:

Magnetic Elements

31

+ F -

AL

The mmf, in the form of a voltage source, applies across the capacitor (the capacitance is AL) and the resistor R. Let the current flowing through this branch be i, and the rms value be Irms, the relationship between the losses due to the leakage flux and the resistance R is:
P loss = I rms R
2

2.5.3 Air Gap


The image and attributes of an air gap element are as follows. Image:
M1 M2

The input parameters of the air gap can be defined in two ways. One is to define the air gap length and the cross section area, and the other is to define the inductance factor AL. They are as follows. Attributes: For the element Air Gap: Parameters Air Gap Length Cross Section Area Resistance for Losses Current Flag Description The length of the air gap, lg, in m Cross section of the air gap, Ac, in m2 Resistance R, in ohm, that represents the losses due to the air gap fringing effect Display flag of the current that flows through the resistor R

32

Power Circuit Components

For the element Air Gap (1): Parameters Inductance Factor AL Resistance for Losses Current Flag Description Inductance factor AL, defined as the inductance per turn squared Resistance R, in ohm, that represents the losses due to the air gap fringing effect Display flag of the current that flows through the resistor R

The resistance R represents the losses due to the air gap fringing effect. Assuming that the mmf (magnetomotive force) applied across the air gap is F, the electric equivalent circuit of the air gap is as follows:
+ F R i

AL

The mmf, in the form of a voltage source, applies across the capacitor (the capacitance has the value of the inductance factor AL) and the resistor R. For the element Air Gap, the inductance factor can be calculated from the air gap length and the cross section area as:
o Ac A L = --------------lg

where o= 4107. The losses on the resistor represents the losses due to the fringing effect, which can be expressed as:
P loss = I rms R
2

where Irms is the rms value of the current i flowing through the resistor.

Magnetic Elements

33

2.5.4 Linear Core


This element represents a linear lossless core. Image:
M1 M2

Attributes: Parameters Inductance Factor AL Description Inductance factor AL of the core, defined as the inductance per turn squared

If the length of the core is Llength and the cross section area is Ac, the inductance factor AL is expressed as:
o r Ac A L = ------------------------L length

where r is the relative permeability of the core material.

2.5.5 Saturable Core


This element models a magnetic core with saturation and hysteresis. Image:
C1 M1 M2

34

Power Circuit Components

Attributes: Parameters Inductance Factor AL Resistance for Losses Saturation Flux Density Bm Coefficient K1 Coefficient Kexp1 Coefficient K2 Coefficient Kexp2 Current Flag Description Inductance factor AL of the core, defined as the inductance per turn squared Resistance R, in Ohm, that represents the core losses Flux density Bm at saturation, in Tesla Coefficient K1 for the core B-H curve Coefficient Kexp1 for the core B-H curve Coefficient K2 for the core B-H curve Coefficient Kexp2 for the core B-H curve Display flag of the current that flows through the resistor R

In the element image, the nodes M1 and M2 are the two nodes that connect to other magnetic elements (such as winding, flux leakage path, air gap, etc.), and the node C1 is an output node that shows the flux of the core. By connecting a voltage probe to this node, the flux of the core can be displayed. Node C1 is a control circuit node. The coefficients K1, Kexp1, K2, and Kexp2 are used to fit the B-H curve of an actual magnetic material. Coefficient K1 usually varies between 0.7 and 1, depending on the core material. Coefficient Kexp1 mainly affects the rate of the core saturation, and is in the range between 10 and 200 (10 for low permeability ferrite, and 200 for metglas). The coefficients K2 and Kexp2 are used in very rare occasions, such as for ferroresonant regulators. They are normally set as follows to keep them from affecting the B-H curve: K2 > 2 Kexp2 > 20

Magnetic Elements

35

2.6

Other Elements

2.6.1 Operational Amplifier


Three op. amp. elements are provided in the PSIM Library: Op. Amp., Op. Amp. (1), and Op. Amp. (2). An ideal operational amplifier (op. amp.) is modelled using power circuit elements, as shown below. Images:
Op. Amp.
VV+ Vo VV+ gnd

Op. Amp. (1)


Vo V+ V-

Op. Amp. (2)


Vo gnd

Circuit Model of the Op. Amp.


V+ VRo A*(V+ - V-) VsVs+

Vo

gnd

where V+; VVo A Ro Attributes: Parameters Voltage Vs+ Voltage VsDescription Upper voltage source level of the op. amp. Lower voltage source levels of the op. amp. - noninverting and inverting input voltages - output voltage - op. amp. gain (A is set to 100,000.) - output resistance (Ro is set to 80 Ohms)

36

Power Circuit Components

The difference between the element Op. Amp. and Op. Amp. (1) or Op. Amp. (2) is that, for the Op. Amp. element, the reference ground of the op. amp. model is connected to the power ground, whereas for Op. Amp. (1) or Op. Amp. (2), the reference ground node of the model is accessible and can be floating. Note that the image of an op. amp. is similar to that of a comparator. For the op. amp., the inverting input is at the upper left and the noninverting input is at the lower left. For the comparator, it is the opposite. Example: A Boost Power Factor Correction Circuit The figure below shows a boost power factor correction circuit. The PI regulators of both the inner current loop and the outer voltage loop are implemented using op. amp.

Comparator

2.6.2 dv/dt Block


A dv/dt block has the same function as the differentiator in the control circuit, except that it is for the power circuit. Image:

The output of the dv/dt block is equal to the derivative of the input voltage versus time. It is calculated as:
V in ( t ) V in ( t t ) V o = --------------------------------------------t

Other Elements

37

where Vin(t) and Vin(t-t) are the input values at the current and previous time step, and t is the simulation time step.

2.6.3 Power Modeling Block


The Power Modeling Block is a type of external DLL block that allows users to define algebraic and differential equations for a device, and to build a model in the power circuit. Unlike conventional DLL blocks that have signal inputs and signal outputs with no consideration of the power conservation (no input and output power balance), the Power Modeling Block allows electric currents to flow in and out of the terminals, and maintains the power balance. The Power Modeling Block provides a very powerful way of modeling power devices. It can have power terminals, control input/output terminals, and mechanical shaft terminals, and equations can be either algebraic or differential, linear or nonlinear. A significant feature of the Power Modeling Block is that these equations are assembled and solved simultaneously with the other equations from the rest of the PSIM circuit, resulting a very robust, stable, and efficient solution. For more information on how to use the Power Modeling Block, refer to the document "Help Power Modeling Block.pdf".

38

Power Circuit Components

2.7

Thermal Module
The Thermal Module is an add-on module to the basic PSIM program. It provides a quick way of estimating the losses of semiconductor devices (diodes, IGBT, and MOSFET). The core of the Thermal Module is the device database. A device database editor is provided to allow users to add new devices to the database and to manage the database easily. The devices in the database can then be used in the simulation for the loss calculation. The following illustrates the process of how a device in the database is used in the simulation and how the losses are calculated: - The behavior model of the device is used in the simulation. The behavior model takes into account the static characteristics of the device (such as conduction voltage drop, on-state resistance, etc.), but not the dynamic characteristics (such as turn-on and turn-off transients). - Based on the voltage and current values from the simulation, PSIM accesses the device database and calculates the conduction losses or switching losses. The static characteristics of the device are updated for the next simulation. Please note that the loss calculation is only approximation and the accuracy of the results depends on the accuracy of the device data, as well as proper scaling of the results from the device test condition to the actual circuit operating conditions. Users should always verify the results with the measurement from the hardware setup. The following sections describe how a device is added to the database, and how it is used in the simulation.

2.7.1 Device Database Editor


The device database editor, PcdEditor.exe, provides an easy and convenient way of adding, editing, and managing devices. An image of the database editor is shown below. On the left are the device database files that are loaded into the database editor, and the list of the devices. The devices can be displayed based on either Device Type or Manufacturer. Also, the device list can be sorted by Part Number, Voltage rating, or Current rating, by clicking on the title bars of the list. On the right is the information of each device. In general, the following information is defined for the device: - Manufacturer and Part Number - Package type - Absolute maximum ratings

Thermal Module

39

- Electrical characteristics - Thermal characteristics - Dimension and weight

Device database files

Device information

Device list

To create a new device file, choose File -> New Device File. To load a device files into the editor, choose File -> Open Device File. To unload a device file from the editor, choose File -> Close Device File. Three types of devices can be added to a device files: diode, IGBT, and MOSFET. However, since dual IGBT-diode modules have a different set of parameters as compared to the regular IGBT devices, they are treated as a separate type (referred to as the IGBT-DIODE type). The sections that follow describe in more details each type of devices. To create a new device, go to the Device menu, and choose either New Diode, New IGBT, New IGBT-Diode, or New MOSFET. To make a copy of an existing device in the same database file, highlight the device in the list, and choose Device -> Save Device As. To make a copy of an existing device and save it in a different database file, first highlight the device in the list, then highlight the file name in the File Name list, and choose Device -> Save Device As.

40

Power Circuit Components

Adding a Device to the Database: To illustrate how to add a device to a database file, below is the step-by-step procedure to add the Powerex discrete diode CS240650 (600V, 50A) into the device database file "diode_new.dev". - Launch PcdEditor.exe. Go to File -> New Device File, and create a file called "diode_new.dev". This file will be placed in the device sub-folder under the PSIM program folder by default. - With the file name "diode_new" highlighted in the "File Name" list, Choose Device -> New Diode. A diode will be added to the database file with Manufacturer as "New" and Part Number as "New". - Obtain the datasheet of Powerex diode CS240650 from the web site www.pwrx.com. Show the PDF file of the datasheet on the screen. - By referring to the information from the datasheet, in the database editor, enter the following information for this device: Manufacturer: Part Number: Package: Vrrm,max (V): IF,max (A): Tj,max (oC): Powerex CS240650 Discrete 600 50 150

and under Absolute Maximum Ratings:

- Define the forward voltage characteristics Vd v.s. IF under Electrical Characteristics by clicking on the Edit button on top of the Vd v.s. IF graph area. The following dialog window will appear. The dialog window has two pages: Graph and Conditions. The Graph page contains thee x and y axis settings as well as the data points and the graph. In this case, the y axis is the conduction voltage drop Vd, and the x axis is the forward current IF. The x and y axis can have multiplying factors (such as m for 10-3, u for 10-6, etc.). The Conditions page contains the conditions under which the graph is obtained.

Thermal Module

41

Graph wizard icons Help area X and Y axis settings Data area

X/Y axis multiplying factor

Graph area

There are two ways to define the graph. One is to enter the graph data points manually. Another is to use the Graph Wizard to capture the graph directly from the datasheet image. Defining the graph manually is preferred if there is only one data point or there are just a few data points. However, if the graph image is available, it is easier with the Graph Wizard. To Define the Graph Manually: - Refer to the "Maximum On-State Characteristics" graph of the datasheet, and enter the values for the x/y axis settings as follows:

42

Power Circuit Components

X0: Xmax: Y0: Ymax: X in log:

1 1000 0.6 2.6 checked

- Visually inspect the graph, and select a few data points. Enter the data points in the data area as follows: (1,0.7) (10,1.05) (100,1.8) (200,2.2) (300,2.4) Then click on the Refresh button to display the graph. - Click on the Conditions tab and enter the Junction Temperature as 25 oC. Alternatively, the graph can be defined in this case using the Graph Wizard. To Define the Graph Using the Graph Wizard: - Click on the forward wizard icon to start the Graph Wizard.

- Display the graph of the datasheet on the screen as follows:

Then press the Print Screen key (the key is labeled as "Prt Scr" on the keyboard) to copy the screen image to the clipboard.

Thermal Module

43

- Click on the forward wizard icon to paste the screen image into the graph window in the database editor. Position the graph image properly in the graph window by dragging the left mouse so that the complete graph is displayed within the window. If the graph image is either too large or too small, go back to the previous step by clicking on the backward wizard icon . Then resize the image of the graph in the Adobe Acrobat, and copy the screen image to the clipboard again. The graph dialog window should look something like follows.

Click on the forward wizard icon

to move on to the next step.

44

Power Circuit Components

- In this step, the border of the graph area is defined by first left clicking at the origin of the graph (usually the lower left corner), then left clicking again at the opposite corner of the origin (usually the upper right corner). Note that the graph origin does not have to be the lower left corner, and it can be any one of the four corners. To locate the origin of the corner more accurately, right mouse click to zoom in, and press the Esc (escape) key to exit the zoom. After this, a blue rectangle will appear around the border of the graph, and the dialog window will appear as follows.

Opposite end of the origin

Origin of the graph

Then click on the forward wizard icon

to move on to the next step.

- In this step, the x and y axis settings will be defined. Enter the settings as

Thermal Module

45

follows: X0: Xmax: Y0: Ymax: X in log: 1 1000 0.6 2.6 checked to move on to the next step.

Click on the forward wizard icon

- Left click on top of the graph to capture the data points. In this case, for example, four data points at the current values of around 1A, 10A, 100A, and 300A are captured. Again, right click to zoom in.

Data points

46

Power Circuit Components

As data points are captured, red lines will appear that will connect the data points. Then click on the forward wizard icon to complete the data capture process. The final graph dialog window should appear as follows.

To see the x and y axis values of a particular data point on the graph, place the cursor inside the graph area. The cursor image will change to a cross image, and the x and y coordinates of the cursor will be displayed at the upper right corner of the dialog window. Place the cursor on top of the curve to read the x and y axis readings. - With the same process, define the reverse recovery characteristics trr v.s. IF, Irr

Thermal Module

47

v.s. IF, and Qrr v.s. IF. - Enter the Thermal Characteristics as: Rth(j-c): Rth(c-s): Length (mm): Width (mm): Height (mm): 0.6 0.4

- Enter the Dimension and Weight as: 53 36 29

Choose Device -> Save Device to save the device information. This completes the process of adding the diode into the database.

2.7.2 Diode Device in the Database


The following information is defined for a diode device in the database: General Information: Manufacturer: Part Number: Package: Discrete Device manufacture Manufacturers part number It can be discrete or dual packages, as shown in the figure below: Dual (Type I) Psw Pcond Dual (Type II) Dual (Type (III)

In the images, beside the diode anode and cathode terminals, there are two extra nodes. The node with a dot is for the diode conduction losses Pcond, and the node with no dot is for the diode switching losses Psw. Absolute Maximum Ratings: Peak reverse blocking voltage Vrrm,max (V): IF,max (A): Maximum dc current

48

Power Circuit Components

Tj,max (oC): Electrical Characteristics: Vd v.s. IF: trr v.s. IF: Irr v.s. IF: Qrr v.s. IF: Thermal Characteristics: Rth(j-c): Rth(c-s): Dimensions and Weight: Length (mm): Width (mm): Height (mm): Weight (g):

Maximum junction temperature Forward conduction voltage drop Vd v.s. forward current IF Reverse recovery time trr v.s. current IF Peak reverse recovery current Irr v.s. current IF Reverse recovery charge Qrr v.s. current IF Junction-to-case thermal resistance, in oC/W Case-to-sink thermal resistance, in oC/W Length of the device, in mm Width of the device, in mm Height of the device, in mm Weight of the device, in g

The losses Pcond and Psw, in watts, are represented in the form of currents which flow out of these nodes. Therefore, to measure and display the losses, an ammeter should be connected between the Pcond or Psw node and the ground. When they are not used, these two nodes cannot be floating, and must be connected to ground.

2.7.3 Diode Loss Calculation


A diode device in the database can be selected and used in the simulation for loss calculation. A diode in the Thermal Module library has the following parameters: Attributes: Parameters Device Frequency Pcond Calibration Factor Psw Calibration Factor Description The specific device selected from the device database Frequency, in Hz, under which the losses are calculated The calibration factor Kcond of the conduction losses Pcond The calibration factor Ksw of the switching losses Psw

The parameter Frequency refers to the frequency under which the losses are calculated. For example, if the device operates at the switching frequency of 10 kHz, and the

Thermal Module

49

parameter Frequency is also set to 10 kHz, the losses will be the values for one switching period. However, if the parameter Frequency is set to 60 Hz, then the losses will be the value for a period of 60 Hz. The parameter Pcond Calibration Factor is the correction factor for the conduction losses. For the example, if the calculated conduction losses before the correction is Pcond_cal, then Pcond = Kcond * Pcond_cal Similarly, the parameter Psw Calibration Factor is the correction factor for the switching losses. For the example, if the calculated switching losses before the correction is Psw_cal, then Psw = Ksw * Psw_cal Conduction Losses: The diode conduction losses is calculated as: Conduction Losses = Vd * IF where Vd is the diode voltage drop, and IF is the diode forward current. Switching Losses: In calculating the switching losses, the diode turn-on losses are neglected and are not considered. The diode turn-off losses due to the reverse recovery is calculated as: Turn-off Losses = 1/4 * Qrr * VR * f where Qrr is the reverse recovery charge, VR is the reverse blocking voltage, and f is the frequency as defined in the input parameter Frequency. The reverse recovery charge Qrr is defined as: Qrr = 1/2 * trr * Irr Whenever Qrr is given in the device database, the losses will be calculated based on Qrr. If Qrr is not given, the losses will be calculated based on trr and Irr. If both are not given, the losses will be treated as 0. Example: Diode Loss Calculation The circuit below shows a sample circuit that uses the Powerexs discrete diode CS240650 (600V, 50A). The conduction losses and the switching losses are measured through two ammeters.

50

Power Circuit Components

Once the information of the losses is available, by building the thermal equivalent circuit, the device junction temperature can be calculated. The circuit shows a thermal circuit without considering the thermal transient.
Speed Sensor

2.7.4 IGBT Device in the Database


An IGBT device has three types of packages: discrete, dual, or 6-pack. For the dual package, both the top and the bottom switches can be IGBTs (full-bridge configuration), or one of the switches is IGBT and the other is a free-wheeling diode (half-bridge configuration). For the half-bridge dual IGBT device, since the freewheeling diode parameters can be different from these of the anti-parallel diode, this type of device is referred to as the IGBT-Diode device, and is treated as a different type in the simulation. But for the convenience of discussion, both devices are referred to as the IGBT devices here. The following information is defined for an IGBT device in the database: General Information: Manufacturer: Part Number: Package: Device manufacture Manufacturers part number It can be discrete, dual, or 6-pack, as shown in the figure below:

Thermal Module

51

Discrete Pcond_Q Psw_Q Pcond_D Psw_D

Dual

6-Pack

Q1 Q4

Q1 Q4

Dual (Type I)

Dual (Type II)

In the images, beside the IGBT and diode terminal nodes, there are four extra nodes from the top to the bottom (or from the left to the right on the top for the 6-pack package). They are the nodes for transistor conductor losses Pcond_Q (the node with a circle), for transistor switching losses Psw_Q, for diode conductor losses Pcond_D (the node with a square), and for diode switching losses Psw_D, respectively. Absolute Maximum Ratings: Maximum collector-emitter voltage Vce,max (V): Ic,max (A): Maximum collector current Tj,max (oC): Maximum junction temperature Electrical Characteristics - Transistor: Collector-emitter saturation voltage Vce(sat) v.s. Vce(sat) v.s. Ic: collector current Ic

52

Power Circuit Components

Eon v.s. Ic: Eoff v.s. Ic:

Turn-on energy losses Eon v.s. collector current Ic Turn-off energy losses Eoff v.s. collector current Ic

Electrical Characteristics - Diode (or Anti-Parallel Diode): Forward conduction voltage drop v.s. forward current Vd v.s. IF: IF trr v.s. IF: Reverse recovery time trr v.s. current IF Irr v.s. IF: Peak reverse recovery current Irr v.s. current IF Qrr v.s. IF: Reverse recovery charge Qrr v.s. current IF Electrical Characteristics - Free-Wheeling Diode (for IGBT-Diode device only): Forward conduction voltage drop v.s. forward current Vd v.s. IF: IF trr v.s. IF: Reverse recovery time trr v.s. current IF Irr v.s. IF: Peak reverse recovery current Irr v.s. current IF Qrr v.s. IF: Reverse recovery charge Qrr v.s. current IF Thermal Characteristics: Rth(j-c) (transistor): Transistor junction-to-case thermal resistance, in oC/ W Rth(j-c) (diode): Diode junction-to-case thermal resistance, in oC/W Rth(c-s): Dimensions and Weight: Length (mm): Width (mm): Height (mm): Weight (g): Case-to-sink thermal resistance, in oC/W Length of the device, in mm Width of the device, in mm Height of the device, in mm Weight of the device, in g

The losses Pcond_Q, Psw_Q, Pcond_D, and Psw_D, in watts, are represented in the form of currents which flow out of these nodes. Therefore, to measure and display the losses, an ammeter should be connected between the nodes and the ground. When they are not used, these nodes cannot be floating and must be connected to ground.

2.7.5 IGBT Loss Calculation


An IGBT device in the database can be selected and used in the simulation for loss calculation. An IGBT device in the Thermal Module library has the following parameters:

Thermal Module

53

Attributes: Parameters Device Frequency Pcond_Q Calibration Factor Psw_Q Calibration Factor Pcond_D Calibration Factor Psw_D Calibration Factor Description The specific device selected from the device database Frequency, in Hz, under which the losses are calculated The calibration factor Kcond_Q of the transistor conduction losses Pcond_Q The calibration factor Ksw_Q of the transistor switching losses Psw_Q The calibration factor Kcond_D of the diode conduction losses Pcond_D The calibration factor Ksw_D of the diode switching losses Psw_D

The parameter Frequency refers to the frequency under which the losses are calculated. For example, if the device operates at the switching frequency of 10 kHz, and the parameter Frequency is also set to 10 kHz, the losses will be the values for one switching period. However, if the parameter Frequency is set to 60 Hz, then the losses will be the value for a period of 60 Hz. The parameter Pcond_Q Calibration Factor is the correction factor for the transistor conduction losses. For the example, if the calculated conduction losses before the correction is Pcond_Q_cal, then Pcond_Q = Kcond_Q * Pcond_Q_cal Similarly, the parameter Psw_Q Calibration Factor is the correction factor for the transistor switching losses. For the example, if the calculated switching losses before the correction is Psw_Q_cal, then Psw_Q = Ksw_Q * Psw_Q_cal Parameters Pcond_D Calibration Factor and Psw_D Calibration Factor work in the same way, except that they are for the diode losses. Conduction Losses: The transistor conduction losses is calculated as: Transistor Conduction Losses = Vce(sat) * Ic

54

Power Circuit Components

where Vce(sat) is the transistor collector-emitter saturation voltage, and Ic is the collect current. Switching Losses: The transistor turn-on losses is calculated as: Transistor Turn-on Losses = Eon * f where Eon is the transistor turn-on energy losses, and f is the frequency as defined in the input parameter Frequency. The transistor turn-off losses is calculated as: Transistor Turn-off Losses = Eoff * f where Eoff is the transistor turn-off energy losses. The loss calculation for the anti-parallel diode or free-wheeling diode is the same as described in the section for the diode device. Example: IGBT Loss Calculation The circuit below shows a sample circuit that uses Powerexs 6-pack IGBT module CM100TU-12H (600V, 100A). The conduction losses and the switching losses of the transistors and the diodes are added separately, and a thermal equivalent circuit is provided to calculate the temperature raise. With the Thermal Module, users can quickly check the thermal performance of a device under different operating conditions, and compare the devices of different manufactures.

Thermal Module

55

2.7.6 MOSFET Device in the Database


The following information is defined for a MOSFET device in the database: General Information: Manufacturer: Part Number: Package: Device manufacture Manufacturers part number It can be discrete, dual, or 6-pack, as shown in the figure below:

56

Power Circuit Components

Discrete (n-channel) Pcond_Q Psw_Q Pcond_D Psw_D (p-channel)

Dual

6-Pack

Q1 Q4

Q1 Q4

In the images, beside the MOSFET and diode terminal nodes, there are four extra nodes from the top to the bottom (or from the left to the right on the top for the 6-pack package). They are the node for transistor conductor losses Pcond_Q (the node with a circle), for transistor switching losses Psw_Q, for diode conductor losses Pcond_D (the node with a square), and for diode switching losses Psw_D, respectively. Absolute Maximum Ratings: VDS,max (V): Maximum drain-to-source voltage ID,max (A): Maximum continuous drain current Tj,max (oC): Maximum junction temperature Electrical Characteristics - Transistor: Static drain-to-source on-resistance (test conditions: RDS(on) (ohm): gate-to-source voltage VGS, in V, and drain current ID, in A) VGS(th) (V): Gate threshold voltage VGS(th) (test condition: drain current ID, in A) gfs (S): Forward transconductance gfs (test conditions: drainto-source voltage VDS, in V, and drain current ID, in A) tr (ns) and tf (ns): Rise time tr and fall time tf (test conditions: drain-tosource voltage VDS, in V; drain current ID, in A; and

Thermal Module

57

gate resistance Rg, in ohm) Total gate charge Qg, gate-to-source charge Qgs, and gate-to-drain ("Miller") charge Qgd, respectively, all in nC (test conditions: drain-to-source voltage VDS, in V; gate-to-source voltage VDS, in V; and drain current ID, in A) Ciss, Coss, and Crss: Input capacitance Ciss, output capacitance Coss, and reverse transfer capacitance Crss, respectively, all in pF (test conditions: drain-to-source voltage VDS, in V; gate-to-source voltage VDS, in V; and test frequency, in MHz) Qg, Qgs, and Qgd: Electrical Characteristics - Diode: Vd v.s. IF: Forward conduction voltage drop Vd v.s. forward current IF trr and Qrr: Reverse recovery time trr, in ns, and reverse recovery charge Qrr, in uC (test conditions: forward current IF, in A; rate of change of the current di/dt, in A/us, and junction temperature Tj, in oC) Thermal Characteristics: Rth(j-c): Rth(c-s): Dimensions and Weight: Length (mm): Width (mm): Height (mm): Weight (g): Junction-to-case thermal resistance, in oC/W Case-to-sink thermal resistance, in oC/W Length of the device, in mm Width of the device, in mm Height of the device, in mm Weight of the device, in g

The losses Pcond_Q, Psw_Q, Pcond_D, and Psw_D, in watts, are represented in the form of currents which flow out of these nodes. Therefore, to measure and display the losses, an ammeter should be connected between the nodes and the ground. When they are not used, these nodes cannot be floating and must be connected to ground.

2.7.7 MOSFET Loss Calculation


A MOSFET device in the database can be selected and used in the simulation for loss calculation. A MOSFET in the Thermal Module library has the following parameters:

58

Power Circuit Components

Attributes: Parameters Device Frequency VGG+ (upper level) VGG- (lower level) Rg_on (turn-on) Rg_off (turn-off) Description The specific device selected from the device database Frequency, in Hz, under which the losses are calculated Upper level of the gate source voltage, in V Lower level of the gate source voltage, in V Gate resistance during turn-on Gate resistance during turn-off. In most cases, the turn-on gate resistance Rg_on and the turn-off gate resistance Rg_off are identical. The calibration factor of the on-state resistance RDS(on) The calibration factor of the forward transconductance gfs The calibration factor Kcond_Q of the transistor conduction losses Pcond_Q The calibration factor Ksw_Q of the transistor switching losses Psw_Q The calibration factor Kcond_D of the diode conduction losses Pcond_D The calibration factor Ksw_D of the diode switching losses Psw_D

RDS(on) Calibration Factor gfs Calibration Factor Pcond_Q Calibration Factor Psw_Q Calibration Factor Pcond_D Calibration Factor Psw_D Calibration Factor

The parameter Frequency refers to the frequency under which the losses are calculated. For example, if the device operates at the switching frequency of 10 kHz, and the parameter Frequency is also set to 10 kHz, the losses will be the values for one switching period. However, if the parameter Frequency is set to 60 Hz, then the losses will be the value for a period of 60 Hz. The parameter Pcond_Q Calibration Factor is the correction factor for the transistor conduction losses. For the example, if the calculated conduction losses before the correction is Pcond_Q_cal, then Pcond_Q = Kcond_Q * Pcond_Q_cal

Thermal Module

59

Similarly, the parameter Psw_Q Calibration Factor is the correction factor for the transistor switching losses. For the example, if the calculated switching losses before the correction is Psw_Q_cal, then Psw_Q = Ksw_Q * Psw_Q_cal Parameters Pcond_D Calibration Factor and Psw_D Calibration Factor work in the same way. except that they are for the diode losses. Conduction Losses: The transistor conduction losses is calculated as: Conduction Losses = ID2 * RDS(on) where ID is the drain current, and RDS(on) is the static on-resistance. Switching Losses: The transistor turn-on losses is calculated as: Transistor Turn-on Losses = Eon * f where Eon is the transistor turn-on energy losses, and f is the frequency as defined in the input parameter Frequency. The transistor turn-off losses is calculated as: Transistor Turn-off Losses = Eoff * f where Eoff is the transistor turn-off energy losses. The energy losses Eon and Eoff are calculated based on the information of the gate current, input/output/reverse transfer capacitances, and gate charges of the MOSFET devices. The loss calculation for the anti-parallel diode or free-wheeling diode is the same as described in the diode device section.

60

Power Circuit Components

2.8

Motor Drive Module


The Motor Drive Module is an add-on module to the basic PSIM program. It provides machine models and mechanical load models for motor drive system studies. The Motor Drive Module includes electric machines as described in this section, and mechanical elements and speed/torque/position sensors as described in Section 2.11.

2.8.1 Reference Direction of Mechanical Systems


In a motor drive system, in order to formulate equations for the mechanical system, a position notation needs to be defined. Take the following motor drive system as an example:

The system consists of two induction machines, IM1 and IM2, connected back-to-back. One operates as a motor, and the other as a generator. From the point of view of the first machine IM1, the mechanical equation can be written as:
d m ( J 1 + J 2 ) --------- = T em1 T em2 dt

where J1 and J2 are the moment of inertia, and Tem1 and Tem2 are the developed torques of the machine IM1 and IM2, respectively. From the point of view of the second machine IM2, however, the mechanical equation can be written as:
d m ( J 1 + J 2 ) --------- = T em2 T em1 dt

These two equations are equally valid, but will produce opposite mechanical speed. In order to avoid this ambiguity, in PSIM, the concept "reference direction" is used in the mechanical system so that the mechanical equation can be uniquely defined. In a mechanical system, one element is designated as the master unit (this element is considered to operate in the master mode), and the rest of the elements are in the slave

Motor Drive Module

61

mode. Elements that can be master units are: Electric machines, mechanical-toelectrical interface blocks, gear boxes, and devices modeled by Power Modeling Blocks. The master unit defines the reference direction of the mechanical system. The direction is define as the direction from the shaft node of the master unit, along the shaft, to the rest of the mechanical system. Once the reference direction of the mechanical system is defined, the speed and torque reference of the mechanical system can be defined. For example, if we use the righthand method, with the thumb pointing in the reference direction of the mechanical system, by rotating the right hand, the fingers will point to the positive direction of the speed and the torque. Moreover, each mechanical element has its own reference direction. The following diagram shows the reference direction of each mechanical element, as indicated by the arrow:
Machines: Mechanical Loads: Encoders:

Speed Sensor:

Torque Sensor:

Gear Box:

Mechanical-Electrical Interface Block:

The reference direction of each element and the reference direction of the overall mechanical system determine how the element interacts with the mechanical system. For example, if the reference direction of a machine is along the same direction as the reference direction of the mechanical system, the developed torque of the machine will contribute to the shaft rotation in the positive direction. However, if the reference direction of the machine is opposite to that of the mechanical system, the developed torque will contribute to the shaft rotation in the negative direction. In the two-machine example above, using the notation of the "reference direction", if we define the machine IM1 as the master unit, the reference direction of the overall mechanical system will be from left to right, as shown below. Based on this direction, the machine IM1 will be along the reference direction, and the machine IM2 will be

62

Power Circuit Components

opposite to the reference direction. This leads to the equivalent circuit of the mechanical system as shown on the right.
Master Unit Equivalent Circuit

Reference direction

(J1+J2)*dWm/dt = Tem1 - Tem2

Similarly, if we define the machine IM2 as the master unit, the reference direction of the overall mechanical system will be from right to left, as shown below. Based on this direction, the machine IM1 will be opposite to the reference direction, and the machine IM2 will be along the reference direction. This leads to the equivalent circuit of the mechanical system as shown on the right.
Master Unit Equivalent Circuit

Reference direction

(J1+J2)*dWm/dt = Tem2 - Tem1

The following shows another mechanical system with sensors and loads connected in different ways.
Master Unit Reference direction of the mechanical system

Load 1

TL1

Speed Sensor 1

Torque Sensor 1

Load 2

TL2

Speed Sensor 2

Torque Sensor 2

Motor Drive Module

63

In this mechanical system, the machine on the left is the master unit. The reference direction of the mechanical system is from left to the right along the mechanical shaft. Comparing this direction with the reference direction of each element, Load 1, Speed Sensor 1, and Torque Sensor 1, will be along the reference direction, and Load 2, Speed Sensor 2, and Torque Sensor 2 will be opposite to the reference direction of the mechanical system. Therefore, if the speed of the machine is positive, Speed Sensor 1 reading will be positive, and Speed Sensor 2 reading will be negative. Similarly, the two constant-torque mechanical loads, with the amplitudes of TL1 and TL2, interact with the machine in different ways. Load 1 is along the reference direction, and the loading torque of Load 1 to the master machine will be TL1. On the other hand, Load 2 is opposite to the reference direction, and the loading torque of Load 2 to the machine will be -TL2.

2.8.2 DC Machine
The image and parameters of a dc machine are as follows: Image:
+
Armature Winding Shaft Node

+
Field Winding

Attributes: Parameters Ra (armature) La (armature) Rf (field) Lf (field) Description Armature winding resistance, in Ohm Armature winding inductance, in H Field winding resistance, in Ohm Field winding inductance, in H

64

Power Circuit Components

Moment of Inertia Vt (rated) Ia (rated) n (rated) If (rated) Torque Flag Master/Slave Flag

Moment of inertia of the machine, in kg*m2 Rated armature terminal voltage, in V Rated armature current, in A Rated mechanical speed, in rpm Rated field current, in A Output flag for internal torque Tem The master/slave flag of the machine

When the torque flag is set to 1, the internal torque generated by the machine will be saved to the output file for display. For more details on the definition and use of the master/slave flag, refer to Section 2.8.1. The operation of a dc machine is described by the following equations:
di a v t = E a + i a R a + L a -----dt di v f = i f R f + L f -----f dt Ea = k m T em = k i a d m J --------- = T em T L dt

where vt, vf, ia, and if are the armature and field winding voltage and current, respectively; Ea is the back emf, m is the mechanical speed in rad./sec., Tem is the internal developed torque, and TL is the load torque. The back emf and the internal torque can also be expressed as:
E a = L af i f m T em = L af i f i a

where Laf is the mutual inductance between the armature and the field windings. It can

Motor Drive Module

65

be calculated based on the rated operating conditions as:


( Vt Ia Ra ) L af = ----------------------------If m

Note that the dc machine model assumes magnetic linearity. Saturation is not considered. Example: A DC Motor with a Constant-Torque Load The circuit below shows a shunt-excited dc motor with a constant-torque load TL. Since the load is along the reference direction of the mechanical system, the loading torque to the machine is TL. Also, the speed sensor is along the reference direction. It will give a positive output for a positive speed. The simulation waveforms of the armature current and the speed are shown on the right.
Speed Sensor

Armature current

ConstantTorque Load

Speed (in rpm)

2.8.3 Induction Machine


Linear and nonlinear models are provided for squirrel-cage and wound-rotor induction machines. The linear model is further divided into general type and symmetrical type. This section describes the linear models. Four linear models are provided: - Symmetrical 3-phase squirrel-cage induction machine - General 3-phase squirrel-cage induction machine - Symmetrical 3-phase wound-rotor induction machine - General 3-phase wound-rotor induction machine The images and parameters are shown as follows.

66

Power Circuit Components

Images:
Squirrel-cage Squirrel-cage (with neutral) Squirrel-cage (unconnected)

as bs cs

as bs cs ns
Wound-rotor

as+ asbs+ bscs+ csWound-rotor (unconnected)

as bs cs ns ar br cr nr

as+ asbs+ bscs+ cs-

ar+

ar- br- crbr+ cr+

Attributes: Parameters Rs (stator) Ls (stator) Rr (rotor) Lr (rotor) Lm (magnetizing) Ns/Nr Turns Ratio No. of Poles Moment of Inertia Torque Flag Master/Slave Flag Description Stator winding resistance, in Ohm Stator winding leakage inductance, in H Rotor winding resistance, in Ohm Rotor winding leakage inductance, in H Magnetizing inductance, in H Stator and rotor winding turns ratio (for wound-rotor machine only) Number of poles P of the machine (an even integer) Moment of inertia J of the machine, in kg*m2 Output flag for internal torque Tem Master/slave flag of the machine

Motor Drive Module

67

All the parameters are referred to the stator side. For more details on the definition and use of the master/slave flag, refer to Section 2.8.1. The models of the squirrel-cage induction machine with and without the neutral are the same internally. The operation of a 3-phase induction machine is described by the following equations:
d d v abc, s = R s i abc, s + L s ---- i abc, s + M sr ---- i abc, r dt dt d v abc, r = R r i abc, r + L r ---- i abc, r + M sr dt
T

d ---- i abc, s dt

where
v a, s v abc, s = v b, s v c, s v a, r v abc, r = v b, r v c, r i a, s i abc, s = i b, s i c, s i a, r i abc, r = i b, r i c, r

For squirrel-cage machines, va,r = vb,r = vc,r= 0. The parameter matrices are defined as:
Rs 0 0 Rs = 0 Rs 0 0 0 Rs L s + M sr Ls = M sr -------2 M sr -------2 M sr -------2 L s + M sr M sr -------2 M sr ------2 M sr ------2 L s + M sr Rr = Rr 0 0 0 Rr 0 0 0 Rr L r + M sr Lr = M sr -------2 M sr -------2 M sr -------2 L r + M sr M sr -------2 M sr -------2 M sr -------2 L r + M sr

cos 2 M sr = M sr cos ----- 3

2 2 cos + ----- cos ----- 3 3 cos 2 cos + ----- 3 cos

2 2 cos + ----- cos ----- 3 3

68

Power Circuit Components

where Msr is the mutual inductance between the stator and rotor windings, and is the mechanical angle. The mutual inductance is related to the magnetizing inductance as:
3 L m = -- M sr 2

The mechanical equation is expressed as:


d m J --------- = T em T L dt

where the developed torque Tem is defined as:


T em = P i abc, s
T

d ----- M sr i abc, r d

For a symmetrical squirrel-cage induction machine, the steady state equivalent circuit is shown below. In the figure, s is the slip.
Rs Ls Lm Rr Lr

Rr(1-s)/s

Example: A VSI Induction Motor Drive System The figure below shows an open-loop induction motor drive system. The motor has 6 poles and is fed by a voltage source inverter with sinusoidal PWM. The dc bus is fed through a diode bridge. The simulation waveforms of the mechanical speed (in rpm), developed torque Tem and load torque Tload, and 3-phase input currents show the start-up transient.

Motor Drive Module

69

VSI Diode Bridge Induction Motor

Speed Torque Sensor Sensor

Speed

SPWM

Tem Tload 3-phase currents

2.8.4 Induction Machine with Saturation


Two models of induction machines with saturation are provided: - 3-phase squirrel-cage induction machine - 3-phase wound-rotor induction machine Images:
Squirrel-cage (nonlinear) Wound-rotor (nonlinear)

as+ asbs+ bscs+ cs-

as+ asbs+ bscs+ csar+ ar- br- crbr+ cr+

70

Power Circuit Components

Attributes: Parameters Rs (stator) Ls (stator) Rr (rotor) Lr (rotor) Ns/Nr Turns Ratio No. of Poles Moment of Inertia Torque Flag Master/Slave Flag Im v.s. Lm (Im1,Lm1) ... Description Stator winding resistance, in Ohm Stator winding leakage inductance, in H Rotor winding resistance, in Ohm Rotor winding leakage inductance, in H Stator and rotor winding turns ratio (for wound-rotor machine only) Number of poles P of the machine (an even integer) Moment of inertia J of the machine, in kg*m2 Output flag for internal torque Tem Master/slave flag of the machine Characteristics of the magnetizing current Im versus the magnetizing inductance [(Im1,Lm1) (Im2,Lm2) ...]

All the parameters are referred to the stator side. For more details on the definition and use of the master/slave flag, refer to Section 2.8.1. The operation of a 3-phase induction machine with saturation is described by the following equations:
d d v abc, s = R s i abc, s + L s ---- i abc, s + ---- abc, s dt dt d d v abc, r = R r i abc, r + L r ---- i abc, r + ---- abc, r dt dt

where
1 1 -2 = M sr 1 1 -2 1 1 - -- -2 2 2 2 1 cos cos + ----- cos ----- - 3 3 2 1 2 2 -- i abc, s + M sr cos ----- cos cos + ----- i abc, r 2 3 3 1 2 2 cos + ----- cos ----- 3 3 cos

abc, s

Motor Drive Module

71

cos 2 abc, s = M sr cos + ----- 3

2 2 cos ----- cos + ----- 3 3 cos 2 cos ----- i abc, s 3 cos

2 2 cos ----- cos + ----- 3 3

1 1 -2 + M sr 1 1 -2 1 1 - -- -2 2

1 -2 1 -- i abc, r 2 1

In this case, the inductance Msr is no longer constant, but a function of the magnetizing current Im.

2.8.5 Brushless DC Machine


A 3-phase brushless dc machine is a type of permanent magnet synchronous machine with trapezoidal waveform back emf. It has 3-phase windings on the stator, and permanent magnet on the rotor. The image and parameters of the 3-phase brushless dc machine are shown as follows. Image:
a b c n sa sb sc
Shaft Node

6-pulse Hall Effect Position Sensor

Attributes: Parameters R (stator resistance) L (stator self ind.) Description Stator phase resistance R, in Ohm Stator phase self inductance L, in H

72

Power Circuit Components

M (stator mutual ind.)

Stator mutual inductance M, in H The mutual inductance M is a negative value. Depending on the winding structure, the ratio between M and the stator self inductance L is normally between -1/3 and -1/2. If M is unknown, a reasonable value of M equal to -0.4*L can be used as the default value.

Vpk / krpm Vrms / krpm

Peak line-to-line back emf constant, in V/krpm (mechanical speed) RMS line-to-line back emf constant, in V/krpm (mechanical speed). The values of Vpk/krpm and Vrms/krpm should be available from the machine data sheet. If these values are not available, they can be obtained through experiments by operating the machine as a generator at 1000 rpm and measuring the peak and rms values of the line-to-line voltage.

No. of Poles P Moment of Inertia Mech. Time Constant theta_0 (deg.)

Number of poles P Moment of inertia J of the machine, in kg*m2 Mechanical time constant mech Initial rotor angle r, in electrical deg. The initial rotor angle is the rotor angle at t=0. The zero rotor angle position is defined as the position where Phase A back emf crosses zero (from negative to positive) under a positive rotation speed.

theta_advance (deg.)

Position sensor advance angle advance, in electrical deg. The advance angle is defined as such that, for a brushless dc machine with a 120o trapezoidal back emf waveform, if the advance angle is 0, the leading edge of the Phase A hall effect sensor signal will align with the intersection of the rising ramp and the flat-top of the back emf trapezoidal waveform.

Motor Drive Module

73

Conduction Pulse Width

Position sensor conduction pulse width, in electrical deg. Positive conduction pulse can turn on the upper switch and negative pulse can turn on the lower switch in a full bridge inverter. The conduction pulse width is 120 electrical deg. for 120o conduction mode. Output flag for internal developed torque Tem Master/slave flag of the machine

Torque Flag Master/Slave Flag

The node assignments of the image are: Nodes a, b, and c are the stator winding terminals for Phase A, B, and C, respectively. The stator windings are Y connected, and Node n is the neutral point. The shaft node is the connecting terminal for the mechanical shaft. They are all power nodes and should be connected to the power circuit. Node sa, sb, and sc are the outputs of the built-in 6-pulse hall effect position sensors for Phase A, B, and C, respectively. The sensor output is a bipolar commutation pulse (1, 0, and -1). The sensor output nodes are all control nodes and should be connected to the control circuit. For more details on the definition and use of the master/slave flag, refer to Section 2.8.1. The equations of the 3-phase brushless dc machine are:
di a v a = R i a + ( L M ) ------ + E a dt di b v b = R i b + ( L M ) ------ + E b dt di c v c = R i c + ( L M ) ------ + E c dt

where va, vb, and vc are the phase voltages, ia, ib, and ic are the phase currents, R, L, and M are the stator phase resistance, self inductance, and mutual inductance, and Ea, Eb, and Ec are the back emf of Phase A, B, and C, respectively. The back emf voltages are a function of the rotor mechanical speed m and the rotor electrical angle r, that is:
E a = k e_a m E b = k e_b m

74

Power Circuit Components

E c = k e_c m

The coefficients ke_a, ke_b, and ke_c are dependent on the rotor angle r. In this model, an ideal trapezoidal waveform profile is assumed, as shown below for Phase A. Also shown is the Phase A hall effect sensor signal Sa.
ke_a Kpk Sa
180 o 360 o

-Kpk

where Kpk is the peak trapezoidal value, in V/(rad./sec.), which is defined as:
V pk krpm 1 K pk = ------------------------ -------------------------------- . Given the values of Vpk/krpm and Vrms/krpm, the 2 1000 2 60

angle is determined automatically in PSIM. The developed torque of the machine is:
T em = ( E a i a + E b i b + E c i c ) m

The mechanical equations are:


d m J --------- = T em B m T load dt d r P ------- = -- m dt 2

where B is a coefficient, Tload is the load torque, and P is the no. of poles. The coefficient B is calculated from the moment of inertia J and the mechanical time constant mech as below:
J B = ---------- mech

More Explanation on the Hall Effect Sensor: A hall effect position sensor consists of a set of hall switches and a set of trigger magnets.

Motor Drive Module

75

The hall switch is a semiconductor switch (e.g. MOSFET or BJT) that opens or closes when the magnetic field is higher or lower than a certain threshold value. It is based on the hall effect, which generates an emf proportional to the flux-density when the switch is carrying a current supplied by an external source. It is common to detect the emf using a signal conditioning circuit integrated with the hall switch or mounted very closely to it. This provides a TTL-compatible pulse with sharp edges and high noise immunity for connection to the controller via a screened cable. For a three-phase brushless dc motor, three hall switches are spaced 120 electrical deg. apart and are mounted on the stator frame. The set of trigger magnets can be a separate set of magnets, or it can use the rotor magnets of the brushless motor. If the trigger magnets are separate, they should have the matched pole spacing (with respect to the rotor magnets), and should be mounted on the shaft in close proximity to the hall switches. If the trigger magnets use the rotor magnets of the machine, the hall switches must be mounted close enough to the rotor magnets, where they can be energized by the leakage flux at the appropriate rotor positions. Example: Start-Up of an Open-Loop Brushless DC Motor The figure below shows an open-loop brushless dc motor drive system. The motor is fed by a 3-phase voltage source inverter. The outputs of the motor hall effect position sensors are used as the gatings signals for the inverter, resulting a 6-pulse operation. The simulation waveforms show the start-up transient of the mechanical speed (in rpm), developed torque Tem, and 3-phase input currents.
Brushless DC Motor

Speed

Tem

3-phase currents

76

Power Circuit Components

Example: Brushless DC Motor with Speed Feedback The figure below shows a brushless dc motor drive system with speed feedback. The speed control is achieved by modulating sensor commutation pulses (Vgs for Phase A in this case) with another high-frequency pulses (Vgfb for Phase A). The high-frequency pulse is generated from a dc current feedback loop. The simulation waveforms show the reference and actual mechanical speed (in rpm), Phase A current, and signals Vgs and Vgfb. Note that Vgfb is divided by half for display purpose.
Brushless DC Motor

Speed Phase A current

Vgfb/2

Vgs

2.8.6 Synchronous Machine with External Excitation


The structure of a conventional synchronous machine consists of three stator windings, one field winding on either a salient or cylindrical rotor, and an optional damping winding on the rotor. Depending on the way the internal model interfaces with the external stator circuitry, there are two types of interface: one is the voltage-type interface, and the other is the current-type interface. The model for the voltage-type interface consists of controlled voltage sources on the stator side, and this model is suitable in situations where the machine operates as a generator and/or the stator external circuit is in series with inductive branches. On the other hand, The model for the current-type interface consists of controlled current sources on the stator side, and this model is suitable in situations where the machine operates as a motor and/or the stator external circuit is in parallel with capacitive branches.

Motor Drive Module

77

The image and parameters of the machine are shown as follows. Image:
a b c n
field+ fieldShaft Node

Attributes: Parameters Rs (stator) Ls (stator) Ldm (d-axis mag. ind.) Lqm (q-axis mag. ind.) Rf (field) Lfl (field leakage ind.) Rdr (damping cage) Ldrl (damping cage) Rqr (damping cage) Lqrl (damping cage) Ns/Nf (effective) Number of Poles P Moment of Inertia Torque Flag Master/slave Flag Description Stator winding resistance, in Ohm Stator leakage inductance, in H d-axis magnetizing inductance, in H q-axis magnetizing inductance, in H. Field winding resistance, in Ohm Field winding leakage inductance, in H Rotor damping cage d-axis resistance, in Ohm Rotor damping cage d-axis leakage inductance, in H Rotor damping cage q-axis resistance, in Ohm Rotor damping cage q-axis leakage inductance, in H Stator-field winding effective turns ratio Number of Poles P Moment of inertia J of the machine, in kg*m2 Output flag for internal developed torque Tem Master/slave flag of the machine

78

Power Circuit Components

All the parameters are referred to the stator side. For more details on the definition and use of the master/slave flag, refer to Section 2.8.1. The equations of the synchronous machine can be expressed as follows:
d V = R I + ---- dt

where
V = va vb vc vf 0 0 R = diag R s R s R s R f R dr R qr
T

I = i a i b i c i f i dr i qr = a b c f dr qr

and [] = [L]*[I]. The inductance matrix is defined as follows:


L 11 L 12
T

L =

L 12 L 22

and
L s + L o + L 2 cos ( 2 r ) Lo 2 ---- + L 2 cos 2 r ----- 3 2 Lo 2 ---- + L 2 cos 2 r + ----- 3 2 Lo ---- + L 2 cos ( 2 r ) 2 2 L s + L o + L 2 cos 2 r ----- 3

Lo 2 2 L 11 = ---- + L 2 cos 2 r ----- L s + L o + L 2 cos 2 r + ----- 3 3 2 Lo 2 ---- + L 2 cos 2 r + ----- 3 2 L sf cos ( 2 r ) Lo ---- + L 2 cos ( 2 r ) 2 L sd cos ( 2 r )

L sq sin ( 2 r )

2 2 2 L sf cos 2 r ----- L sd cos 2 r ----- L sq sin 2 r ----- L 12 = 3 3 3 2 2 2 L sf cos 2 r + ----- L sd cos 2 r + ----- L sq sin 2 r + ----- 3 3 3 L f L fdr 0 L 22 = L fdr L dr 0 0 0 L qr

Motor Drive Module

79

where r is the rotor angle. The developed torque can be expressed as:
d P T = -- I ------- L I d r 2

The mechanical equations are:


d m J --------- = T em T load dt d r P ------- = -- m dt 2

2.8.7 Permanent Magnet Synchronous Machine


A 3-phase permanent magnet synchronous machine has 3-phase windings on the stator, and permanent magnet on the rotor. The difference between this machine and the brushless dc machine is that the machine back emf is sinusoidal. The image and parameters of the machine are shown as follows. Image:
a b c
n
Shaft Node

Attributes: Parameters Rs (stator resistance) Ld (d-axis ind.) Description Stator winding resistance, in Ohm Stator d-axis inductance, in H

80

Power Circuit Components

Lq (q-axis ind.)

Stator q-axis inductance, in H. The d-q coordinate is defined such that the d-axis passes through the center of the magnet, and the q-axis is in the middle between two magnets. The q-axis is leading the daxis.

Vpk / krpm

Peak line-to-line back emf constant, in V/krpm (mechanical speed). The value of Vpk/krpm should be available from the machine data sheet. If this data is not available, it can be obtained through an experiment by operating the machine as a generator at 1000 rpm and measuring the peak line-to-line voltage.

No. of Poles P Moment of Inertia Mech. Time Constant Torque Flag Master/slave Flag

Number of poles P Moment of inertia J of the machine, in kg*m2 Mechanical time constant mech Output flag for internal developed torque Tem Master/slave flag of the machine

The node assignments of the image are: Nodes a, b, and c are the stator winding terminals for Phase a, b, and c, respectively. The stator windings are Y connected, and Node n is the neutral point. The shaft node is the connecting terminal for the mechanical shaft. They are all power nodes and should be connected to the power circuit. For more details on the definition and use of the master/slave flag, refer to Section 2.8.1. The equations of the permanent-magnet synchronous machine are:
va vb vc = Rs 0 0 a ia d i b + ---- b 0 Rs 0 dt ic c 0 0 Rs

where va, vb, vc, and ia, ib, and ic, and a, b, c are the stator phase voltages, currents, and flux linkages, respectively, and Rs is the stator phase resistance. The flux linkages are further defined as:

Motor Drive Module

81

a b c

cos ( r ) L aa L ab L ac ia 2 ----= L ba L bb L bc i b + pm cos r 3 L ca L cb L cc ic 2 cos r + ----- 3

where r is the rotor electrical angle, and pm is a coefficient which is defined as:
60 V pk krpm pm = -------------------------------------3 P 1000

where P is the number of poles. The stator self and mutual inductances are rotor position dependent, and are defined as:
L aa = L s + L o + L 2 cos ( 2 r ) 2 L bb = L s + L o + L 2 cos 2 r + ----- 3 2 L cc = L s + L o + L 2 cos 2 r ----- 3 Lo 2 L ab = L ba = ---- + L 2 cos 2 r ----- 3 2 Lo 2 L ac = L ca = ---- + L 2 cos 2 r + ----- 3 2 Lo L bc = L cb = ---- + L 2 cos ( 2 r ) 2

where Ls is the stator leakage inductance. The d-axis and q-axis inductances are associated with the above inductances as follows:
3 3 L d = L s + -- L o + -- L 2 2 2 3 3 L q = L s + -- L o -- L 2 2 2

The developed torque can be expressed as:

82

Power Circuit Components

sin ( 2 r ) T em

2 2 sin 2 r ----- sin 2 r + ----- 3 3 sin ( 2 r ) 2 sin 2 r ----- 3

P = -- L 2 i a i b i c sin 2 r 2 sin 2 r + 2 --------2 3 3 2 sin 2 r + ----- 3 sin ( 2 r ) sin ( r ) 2 P ----= -- pm i a i b i c sin r 3 2 2 sin r + ----- 3

ia ib ic

The mechanical equations are:


d m J --------- = T em B m T load dt d r P ------- = -- m dt 2

where B is a coefficient, Tload is the load torque, and P is the no. of poles. The coefficient B is calculated from the moment of inertia J and the mechanical time constant mech as below:
J B = ---------- mech

2.8.8 Permanent Magnet Synchronous Machine with Saturation


A 3-phase PMSM machine with saturation differs from that of a linear 3-phase PMSM machine in that the d-axis and q-axis magnetizing inductances Ldm and Lqm can be expressed as a nonlinear function of the d-axis and q-axis currents in the lookup table form. The image and parameters of the machine are shown as follows. Image:

Motor Drive Module

83

a b c
n
Shaft Node

Attributes: Parameters Rs (stator resistance) Ls (stator leakage ind.) Vpk / krpm Description Stator winding resistance, in Ohm Stator d-axis inductance, in H Peak line-to-line back emf constant, in V/krpm (mechanical speed). The value of Vpk/krpm should be available from the machine data sheet. If this data is not available, it can be obtained through an experiment by operating the machine as a generator at 1000 rpm and measuring the peak line-toline voltage. No. of Poles P Moment of Inertia Mech. Time Constant Ld Lookup Table File Lq Lookup Table File dq Flag Number of poles P Moment of inertia J of the machine, in kg*m2 Mechanical time constant mech, in sec. It is associated with the friction coefficient B as: B = J / mech. File name of the lookup table for Ldm File name of the lookup table for Lqm Flag for the lookup table. When the flag is 0, Ldm and Lqm are function of Id and Iq. When the flag is 1, Ldm and Lqm are function of the current magnitude Im and the angle. Flag for the transformation convention (see details below) Output flag for internal developed torque Tem Master/slave flag of the machine

Transformation Flag Torque Flag Master/Slave Flag

84

Power Circuit Components

For more details on the definition and use of the master/slave flag, refer to Section 2.8.1. The relationship between the d-axis/q-axis inductances Ld/Lq and the magnetizing inductances Ldm/Lqm is as follows:
L d = L s + L dm L q = L s + L qm

where Ls is the stator leakage inductance. Since Ls is normally very small, Ld can be considered equivalent to Ldm, and Lq can be considered equivalent to Lqm. The Transformation Flag defines the transformation convention between the abc frame and the dq frame. When the Transformation Flag is 0:
2 2 cos ( r ) cos r ----- cos r + ----- 3 3 2 2 sin ( r ) sin r ----- sin r + ----- 3 3 Im = Id + Iq
2 2

Id Iq

2 = -- 3

ia ib ic

m = atan 2 ( I q, I d )

The current vector angle is in deg., and is from -180o to 180o. When the Transformation Flag is 1:
2 2 cos ( r ) cos r ----- cos r + ----- 3 3 2 2 sin ( r ) sin r ----- sin r + ----- 3 3 Im = 2 I2 + I2 -d q 3 ia ib ic

Id Iq

2 -- 3

m = atan 2 ( I d, I q )

The current vector angle is in deg., and is from 0o to 360o.

Motor Drive Module

85

The Ldm and Lqm lookup tables have the following format: m, n Vr,1, Vr,2, ..., Vr,m Vc,1, Vc,2, ..., Vc,n L1,1, L1,2, ..., L1,n L2,1, L2,2, ..., L2,n ... ... ... Lm,1, Lm,2, ..., Lm,n where m is the number of rows and n is the number of columns; Vr is the row vector and Vc is the column vector; and Li,j is the Ldm or Lqm inductance value, in H, at Row i and Column j. Note that Vectors Vr and Vc must be monotonically increasing. If the input is between two points, interpolation is used to calculate the value. If the input is less than the minimum or greater than the maximum value, the input will be set to be the same as the minimum or maximum value. This PMSM model with saturation can also be used as the linear PMSM model if the lookup tables are defined such that Ldm and Lqm are linear function of Id and Iq. The following shows an example of the lookup table:
4,15 -5.7155 -4.8990 -4.0825 -3.2660 -5.7155 -4.8990 -4.0825 -3.2660 -2.4495 -1.6330 -0.8165 0 0.8165 1.6330 2.4495 3.2660 4.0825 4.8990 5.7155 0.0109 0.0109 0.0107 0.0104 0.0102 0.0100 0.0098 0.0098 0.0098 0.0100 0.0102 0.0104 0.0107 0.0109 0.0109 0.0109 0.0109 0.0109 0.0106 0.0109 0.0106 0.0105 0.0105 0.0105 0.0106 0.0109 0.0106 0.0109 0.0109 0.0109 0.0109 0.0109 0.0109 0.0109 0.0111 0.0108 0.0106 0.0106 0.0106 0.0108 0.0111 0.0109 0.0109 0.0109 0.0109 0.0110 0.0110 0.0111 0.0110 0.0110 0.0109 0.0108 0.0107 0.0108 0.0109 0.0110 0.0110 0.0111 0.0110 0.0110

86

Power Circuit Components

2.8.9 Switched Reluctance Machine


The model of a 3-phase switched reluctance machine with 6 stator teeth and 4 rotor teeth is provided. The images and parameters are shown as follows. Image:
a+ ab+ bc+ cShaft Node

c1 c2 c3 c4 c1
Phase a

c4 c1

c4

Phase b

Phase c

Attributes: Parameters Resistance Inductance Lmin Inductance Lmax r Moment of Inertia Torque Flag Master/Slave Flag Description Stator phase resistance R, in Ohm Minimum phase inductance, in H Maximum phase inductance, in H Duration of the interval where the inductance increases, in deg. Moment of inertia J of the machine, in kg*m2 Output flag for internal torque Tem Master/slave flag of the machine

For more details on the definition and use of the master/slave flag, refer to Section 2.8.1. The node assignments are: Nodes a+, a-, b+, b-, and c+, c- are the stator winding terminals for Phase a, b, and c, respectively. The shaft node is the connecting terminal for the mechanical shaft. They are all power nodes and should be connected to the power circuit. Node c1, c2, c3, and c4 are the control signals for Phase a, b, and c, respectively. The control signal value is a logic value of either 1 (high) or 0 (low). Node is the

Motor Drive Module

87

mechanical rotor angle. They are all control nodes and should be connected to the control circuit. The equation of the switched reluctance machine for one phase is:
d(L i) v = i R + ---------------dt

where v is the phase voltage, i is the phase current, R is the phase resistance, and L is the phase inductance. The phase inductance L is a function of the rotor angle , as shown in the following figure.
L Lmax Lmin
Rising Flat-Top Falling Flat-Bottom

The rotor angle is defined such that, when the stator and the rotor teeth are completely out of alignment, = 0. The value of the inductance can be in either rising stage, flat-top stage, falling stage, or flat-bottom stage. If we define the constant k as:
L max L min k = -------------------------

we can express the inductance L as a function of the rotor angle : L = Lmin + k L = Lmax L = Lmax - k L = Lmin [rising stage. Control signal c1=1) [flat-top stage. Control signal c2=1) [falling stage. Control signal c3=1) [flat-bottom stage. Control signal c4=1)

The selection of the operating state is done through control signals c1, c2, c3, and c4 which are applied externally. For example, when c1 in Phase a is high (1), the rising stage is selected and Phase a inductance will be: L = Lmin + k . Note that only one and at least one control signal out of c1, c2, c3, and c4 in one phase must be high (1).

88

Power Circuit Components

The developed torque of the machine per phase is:


1 2 dL T em = -- i ----2 d

Based on the inductance expression, we have the developed torque in each stage as: Tem = i2*k / 2 Tem = 0 Tem = - i2*k / 2 Tem = 0 [rising stage] [flat-top stage] [falling stage] [flat-bottom stage]

Note that saturation is not considered in this model.

Motor Drive Module

89

2.9

MagCoupler Module
The MagCoupler Module provides interface for co-simulation between PSIM and the software JMAG. JMAG is an electromagnetic field analysis software for the development and design of electric machines, actuators, and other electrical and electronic devices and components. With the MagCoupler Module, one can perform power electronics and control analysis and simulation, as well as the electromagnetic field analysis, all in one integral environment. The MagCoupler Module includes the MagCoupler interface block as described in this section, and mechanical elements and speed/torque/position sensors as described in Section 2.11. To run the MagCoupler Module, the path of the JMAG directory must be included in PSIM so that PSIM can load JMAG DLL files. To set the JMAG directory path in PSIM, go to Options -> Set Path, and click on Add Folder to include the JMAG directory. Also, the MagCoupler Module requires Microsoft Internet Explorer Version 6 or higher. It will not work with Internet Explorer Version 5. Image:
Block with 4 inputs and 4 outputs

Attributes: Parameter Link Table File JMAG Input File Description The XML file that defines the interface between PSIM and JMAG. It has the .xml extension. The JCF input data file for JMAG. It has the .jcf extension. Note that the .xml file and the .jcf file must be in the same directory. Comments for the JMAG circuit Nodes that pass the values from PSIM to JMAG

JMAG Case Text IN Nodes

90

Power Circuit Components

OUT Nodes

Nodes that pass the values from JMAG to PSIM

The number of input and output nodes may vary, depending on the actual number of input/output nodes in a particular circuit. The MagCoupler block accepts voltages, currents, and positions as inputs, and it provides voltages, currents, positions, torques, and force as the outputs. In PSIM, the MagCoupler block is a power circuit element. The way it interfaces with the rest of the circuit is that both the inputs and outputs are voltage signals (no electric current flows into the input node). To convert a branch current into a voltage signal, or vice versa, one can use a current-controlled voltage source, or voltage-controlled current source. The Link Table File, in XML format, defines the input/output interface and corresponding functions in JMAG. This file is generated automatically by JMAG. To locate this file, click on the browse button at the right of the edit field.

The JMAG Input File is the JCF input data file that is read by the JMAG solver. The name is defined in the Link Table File. Note that JCF input file .jcf must be in the same directory as the input link table file .xml. If any material database is used in JMAG, it should also be placed in the directory of the .xml file. Also, the .xml file does not have to be in the same directory as the schematic file. However, if a .xml file with the same name is present in the schematic directory, PSIM will read the one in the schematic directory first. The JMAG Case Text is a text identifying the specific JMAG circuit. It can be any text describing the JMAG circuit. The IN Nodes are the nodes through which PSIM passes the values to JMAG. In the MagCoupler block image, the order of the input nodes is from the top to the bottom. The order can be changed by highlighting the node and click on the upper or down arrow. The OUT Nodes are the nodes through which JMAG passes the values back to PSIM. In the MagCoupler block image, the order of the output nodes is from the top to the bottom. The order can be changed by highlighting the node and click on the upper or down arrow. By clicking on the Edit Image button, one can edit and customize the image of the MagCoupler block. Clicking on the Display File button will display the Link Table File in the Microsoft Internet Explorer environment, and clicking on the Read File button will read or re-load the Link Table File. Set-up in JMAG and PSIM: Using the MagCoupler block, it is easy to set up the link between JMAG and PSIM for co-simulation. It involves two main steps: setting up the circuit in JMAG and generating

MagCoupler Module

91

the link table file, and loading the link table file into PSIM. An inductor example below is used to illustrate this process. In the PSIM circuit of this example, the circuit on the left uses the built-in inductor element from the PSIM library, and the circuit on the right has the inductor implemented in JMAG. In this case, the inductor is modelled as a controlled current source in PSIM. The voltage across the inductor is first converted to a node-to-ground voltage through a voltage-controlled voltage source, and the value is passed to the input node VL of the MagCoupler block. At each time step, PSIM calls JMAG functions which calculate the inductor current based on the voltage input. This current is then sent back to PSIM in the voltage form, and is used to control the current source that represents the inductor. In the JMAG circuit of this example, the voltage function (on the left side) receives the voltage from PSIM, and through the current probe in series with the FEM coil, the current is calculated and sent back to PSIM. The inductor structure in the JMAG environment is shown on the lower right.
Circuit in PSIM (file: inductor_jmag.sch)

Circuit and Structure in JMAG (file: inductor.jsp)

92

Power Circuit Components

The setup process of calling JMAG in PSIM through the MagCoupler block is as follows. In JMAG: - In the JMAG circuit, connect a voltage function to the right of the FEM coil. Under Electrical Potential in the property window, choose Constant Value, and set Constant Value[V] to 0. - Connect a current probe to the left of the FEM coil. - Connect another voltage function to the left of the current probe (the circuit will look like what is shown above). In the property window, choose Cooperates with an external circuit simulator. - Highlight the inductor structure window. Go to the menu Conditions -> Create Conditions. From the Conditions List, highlight Coupled External Circuit Simulator, and click Modify. - On the Coupled External Circuit Simulator dialog window, there are two lists. The list on the right, called JMAG, contains all the functions that can be used to interface with PSIM. The list on the left, called External Circuit Simulator, contains the functions that are selected to interface with PSIM. In this case, there are two items in the JMAG list, one is the Voltage Function, and the other is the Current Probe. - Highlight the Voltage Function, and click on the <- button to move the item from the list on the right to the list on the left. Repeat the same step to the Current Probe. Now both items should appear in the list on the left. - Highlight the Voltage Function, and change the terminal name to VL. Also, change the Current Probe terminal name to iL. Close the dialog window. - Go to the menu File -> Export and select JCF.... With the JCF file name defined as "inductor", the JCF file "inductor.jcf" and the link table file "inductor_csl.xml" will be generated. - Copy the JCF file "inductor.jcf" and the link table file "inductor_csl.xml" to the folder containing the PSIM schematic file "inductor_jmag.sch". Rename the link table file to "inductor_jmag.xml". Note that the XML file does not have to be renamed, and both the JCF and XML files do not have to be moved to the folder of the schematic file. They are done here for the simplicity of file management In PSIM: - After the rest of the power circuit is created, go to Elements -> Power ->

MagCoupler Module

93

MagCoupler Module, and select MagCoupler Block. Place the block on the schematic. - Double click on the MagCoupler block to bring out the property window. click on the browser button next to the Link Table File edit field to locate and select the file "inductor_jmag.xml". After the file is read, the property window will display the IN node VL and the OUT node iL. - Connect the MagCouple block to the rest of the circuit in the schematic. The setup is now complete and the simulation is ready to run.

94

Power Circuit Components

2.10 MagCoupler-RT Module


The MagCoupler-RT Module provides interface between PSIM and JMAG-RT data files. JMAG-RT is another way of modeling electromagnetic devices. The JMAG-RT data files are obtained by running the JMAG simulation in advance, and are stored in a lookup table form. During the PSIM simulation, JMAG is no longer needed, and PSIM interfaces directly with the JMAG-RT data. The biggest advantage of JMAG-RT is that, since the JMAG-RT data files are obtained from the JMAG dynamic simulation, the accuracy of the JMAG-RT model is comparable to that of a JMAG dynamic model. However, since JMAG is not involved in the PSIM simulation, the PSIM simulation is significantly faster. The MagCoupler Module includes the MagCoupler-RT blocks as described in this section, and mechanical elements and speed/torque/position sensors as described in Section 2.11. Images:
MagCoupler-RT PMSM Block A B C MagCoupler-RT Block A+ A- B+ B- C+ C-

M-

M+ MM+

Attributes: Parameter Netlist XML File JMAG-RT Input File JMAG Case Text Terminal Names Description The XML file that defines the interface between PSIM and JMAG-RT. It has the .xml extension. The JMAG-RT data file. It has the .rtt extension. Note that the .xml file and the .rtt file must be in the same directory. Comments for the JMAG-RT circuit Terminal names of the block

MagCoupler-RT Module

95

In the MagCoupler-RT block images, the electric nodes (such as A, B, C, A+, A-, B+, B, C+, and C-, as shown above) are placed at the top of the block, arranged from the left to the right. The rotor shaft nodes are placed on the left and right of the block, with the first shaft node (such as M+ as shown above) on the right, and the second shaft node (such as M-) on the left. The electric nodes and rotor shaft nodes, as well as the rest of the interface between PSIM and the JMAG-RT data files, are defined in the JMAG-RT Input File. This file is in XML format, and is generated by the JMAG-RT Manager. To specify this file, click on the browse button at the right of the edit field. The JMAG-RT Input File is the JMAG-RT data file for the device modeled. The file has the .rtt extension and is defined in the JMAG-RT Input File. Note that the .rtt file and the .xml file must be in the same directory. The JMAG Case Text is a text identifying the specific JMAG-RT study case. It can be any text. The Terminal Names are the names of the interface nodes. The nodes on the top of the block are the power circuit nodes, and the nodes on the left and right of the blocks are the mechanical shaft nodes. Example: A PMSM motor drive system with PMSM modeled in JMAG-RT The figure below shows a permanent-magnet synchronous motor (PMSM) drive system, with the PMSM modeled in JMAG-RT.

The figure below shows the property window of the MagCoupler-RT PMSM block. The .xml file in this example defines three electric nodes (Nodes U, V, and W), and two rotor shaft nodes (Nodes shaft+ and shaft-). The shaft nodes can be connected directly to

96

Power Circuit Components

other mechanical elements in the PSIM library, as shown in this case. Besides the information of the .rtt file and the terminal names, the property window also shows a set of parameters that allow users to modify the values of selected variables in the JMAG-RT data file. The last five parameters are the flags that, when set to 1, will display the currents, back emf, as well as the rotor angle, speed, and the developed torque of the machine. For definitions and the usage of these parameters, please consult the relevant JMAG-RT document.

MagCoupler-RT Module

97

2.11 Mechanical Elements and Sensors


This section describes elements that are shared by Motor Drive Module, MagCoupler Module, and MagCoupler-RT Module. The elements include mechanical loads, gear boxes, mechanical coupling blocks, mechanical-electrical interface blocks, and various speed/torque/position sensors.

2.11.1 Mechanical Loads


Several mechanical load models are provided: constant-torque, constant-power, constant-speed, general-type, and externally controlled loads.

2.11.1.1 Constant-Torque Load


The image of a constant-torque load is: Image:

Attributes: Parameters Constant Torque Moment of Inertia Description Torque constant Tconst, in N*m Moment of inertia of the load, in kg*m2

If the reference direction of a mechanical system enters the dotted terminal, the load is along the reference direction, and the loading torque to the master machine is Tconst. Otherwise the loading torque will be -Tconst. See Section 2.6.1 for more detailed explanation on the reference direction. A constant-torque load is expressed as:
T L = T const

The torque does not depend on the speed direction.

98

Power Circuit Components

2.11.1.2 Constant-Power Load


The image of a constant-power load is: Image:

Attributes: Parameters Maximum Torque Base Speed Moment of Inertia Description Maximum torque Tmax of the load, in N*m Base speed nbase of the load, in rpm Moment of inertia of the load, in kg*m2

The torque-speed curve of a constant-power load is shown below:


Tmax Torque (N*m)

nbase

Speed (rpm)

When the mechanical speed is less than the base speed nbase, the load torque is:
T L = T max

When the mechanical speed is above the base speed, the load torque is:
PT L = --------m

where P = Tmax*base and base = 2nbase/60. The mechanical speed m is in rad./sec.

Mechanical Elements and Sensors

99

2.11.1.3 Constant-Speed Load


The image of a constant-torque load is: Image:

Attributes: Parameters Constant Speed (rpm) Moment of Inertia Description Speed constant, in rpm Moment of inertia of the load, in kg*m2

A constant-speed mechanical load defines the speed of a mechanical system, and the speed will remain constant, as defined by the speed constant.

2.11.1.4 General-Type Load


The image of a general-type mechanical load is as follows. Image:

Attributes: Parameters Tc k1 (coefficient) k2 (coefficient) k3 (coefficient) Moment of Inertia Description Constant torque term Coefficient for the linear term Coefficient for the quadratic term Coefficient for the cubic term Moment of inertia of the load, in kg*m2

A general-type load is expressed as:

100

Power Circuit Components

T L = sign ( m ) ( T c + k 1 m + k 2 m + k 3 m )

where m is the mechanical speed in rad./sec. Note that the torque of the general-type load is dependent on the speed direction.

2.11.1.5 Externally-Controlled Load


An externally-controlled mechanical load is used to define a load of an arbitrary load profile. Image:

Attributes: Parameters Speed Flag Description Flag for speed dependency (Flag = 0: The load is frictional and is always against the rotational direction; Flag = 1: The load is independent of the rotational direction.) Moment of Inertia Moment of inertia of the load, in kg*m2

The value of the mechanical load is defined by the voltage value at the control node (1V corresponds to 1 N*m). This node is a control circuit node.

2.11.2 Gear Box


The image is a gear box is shown below. Image:
Shaft 1 Shaft 2

Mechanical Elements and Sensors

101

Attribute: Parameter Gear Ratio Shaft 1 Master/Slave Flag Shaft 2 Master/Slave Flag Description The gear ratio a Master/slave flag for Shaft 1 Master/slave flag for Shaft 2

The shaft with the bigger dot is Shaft 1. If the numbers of teeth of the first gear and the second gear are n1 and n2, respectively, the gear ratio a is defined as: a = n1 / n2. Let the radius, torque, and speed of these two gears be: r1, r2, T1, T2, 1, and 2, we have: T1 / T2 = r1 / r2 = 2 / 1= a. The two shafts of the gear box can be in either master mode or slave mode. For more information on the definition and use of the master/slave flag, refer to Section 2.8.1.

2.11.3 Mechanical Coupling Block


The mechanical coupler block is used to couple two mechanical systems. Image:
Mechanical System #1 Mechanical System #2

This block is used in situations where both mechanical systems have a device in the master mode, and they must be connected together to form one system. Based on the connection convention in PSIM, a mechanical system can have only one master device. In this case, the mechanical coupling block can be inserted in between, and the mechanical system on each side of the coupling block can have its own device in the master mode.

2.11.4 Mechanical-Electrical Interface Block


This block allows users to access the internal equivalent circuit of the mechanical system of a machine. Image:
Mechanical Side Electrical Side

102

Power Circuit Components

Attribute: Parameter Master/Slave Flag Description Flag for the master/slave mode (1: master, 0: slave)

Similar to electric machines, the mechanical-electrical interface block can be used to define the reference direction of a mechanical system through the master/slave flag. When the interface block is set to the master mode, the reference direction is along the mechanical shaft, away from the mechanical node, and towards the rest of the mechanical elements. Lets assume that a drive system consists of a motor (with a developed torque of Tem and a moment of inertia of J1) and a mechanical load (with a load torque of Tload and a moment of inertia of J2). The equation that describes the mechanical system is:
d m ( J 1 + J 2 ) --------- = T em T load dt

where m is the shaft mechanical speed. In PSIM, this equation is modelled by an equivalent circuit as shown below.

m
Tem J1 J2

speed node
Tload

In this circuit, the two current sources have the values of Tem and Tload, and the capacitors have the values of J1 and J2. The node-to-ground voltage (speed node voltage) represents the mechanical speed m. This is analogous to C*dV/dt = i for a capacitor where C = J1+J2, V = m, and i = Tem-Tload. In PSIM, mechanical equivalent circuits for motors and mechanical loads all use the capacitor-based circuit model. The mechanical-electrical interface block provides the access to the internal mechanical equivalent circuit. If the mechanical side of an interface block (with the letters M) is connected to a mechanical shaft, the electrical side (with the letters E) will be the speed node of the mechanical equivalent circuit. One can thus connect any electrical circuits to this node. With this element, users can connect built-in motors or mechanical loads with userdefined load or motor models.

Mechanical Elements and Sensors

103

Example: An induction machine with a custom mechanical load model The figure below shows an induction machine connected to a user defined mechanical load model through the mechanical-electrical interface block. As explained above, the voltage at the electrical side represents the shaft mechanical speed. A current source flowing out of this node represents a mechanical load, and a capacitor connected to this node represents the load moment of inertia.

Mechanical load model

Example: A custom machine model with a constant-torque load Similarly, one can build a custom machine model and connect it to the mechanical load in PSIM. The figure below shows such a circuit. The custom machine model must use the capacitor analogy to model the mechanical equation. The node representing the mechanical speed is then made available and is connected to the electrical side of the mechanical-electrical interface block.
Custom machine model (in subcircuit form)

Wm Mechanical speed

104

Power Circuit Components

2.11.5 Speed/Torque Sensors


A speed sensor or torque sensor is used to measure the mechanical speed or torque. Images:
Speed Sensor Torque Sensor

Attribute: Parameter Gain Description Gain of the sensor

The output of the speed sensor is in rpm. The output of the speed/torque sensor depends on how the sensor is connected in a mechanical system. For the speed sensor, if the sensor is along the reference direction of the mechanical system (refer to Section 2.8.1 for more details on the definition and use of the reference direction), a positive mechanical speed would give a positive sensor output. Otherwise, if the sensor is opposite to the reference direction of the mechanical system, a positive mechanical speed would give a negative sensor output. For example, in the mechanical system below, Speed Sensor 1 is along the reference direction, and Speed Sensor 2 is opposite to the reference direction of the mechanical system. If the actual mechanical speed is positive, the output of Speed Sensor 1 will be positive, and the output of Speed Sensor 2 will be negative.
Reference direction of the mechanical system

Speed Sensor 1

Speed Sensor 2

The torque sensor measures the torque difference between the dotted side of the sensor and the undotted side. To understand the physical meaning of the torque sensor measurement, we use the diagram below as an illustration.

Mechanical Elements and Sensors

105

The figure on the left shows a torque sensor connected with a 10-N*m mechanical load, and the reference direction of the mechanical system is from left to right. Based on the reference direction, if we use the right-hand method, by pointing the thumb in the reference direction and rotating the right hand, the direction of the fingers will show the direction of the positive speed and torque. The physical interpretation of the system is shown on the right.
Reference direction of the mechanical system Physical interpretation

*
10 Wm Torque sensor Load 10

In this case, the direction of the positive speed and torque is in the clockwise direction. The dotted side of the sensor is on the left, and the load is in such a way that it tries to slow down the shaft (the load torque is in the counter-clockwise direction). The physical meaning of the torque sensor is that, if the dotted side of the sensor is fixed, the sensor will measure the torque tension on the undotted side of the sensor, and a positive sensor output would mean that the torque is opposite to the direction of the speed reference. Therefore, for the example above, the positive speed reference is in the clockwise direction, and the load torque is in the counter-clockwise direction. This will give a torque sensor reading of 10 N*m. Similarly, if the undotted side of the sensor is fixed, the sensor will measure the torque tension on the dotted side of the sensor, in the positive direction of the speed reference. For example, in the system below, the torque sensor is flipped with the dotted side on the right. If the undotted side is fixed, the load torque is applied to the dotted side of the sensor, in the opposite direction of the speed reference. The torque sensor output will be -10 N*m instead.
Reference direction of the mechanical system Physical interpretation

*
10 Wm Torque sensor Load 10

To understand how the torque sensor is modeled in the equivalent circuit of the mechanical system, we use the following system as an example.

106

Power Circuit Components

Load 1 Sensor 1 Sensor 2

Load 2

Tem J

TL1 JL1

TL2 JL2

The system consists of one machine, 2 torque sensors, and 2 mechanical loads. The torques and moment of inertia for the machine and the loads are as labelled in the diagram. The reference direction of this mechanical system is from left to right. The equation for this system can be written as:
d m ( J + J L1 + J L2 ) --------- = T em T L1 T L2 dt

The equivalent electrical circuit of the equation is shown below:


m Sensor 1 Sensor 2

Tem

J Machine

-TL1 Load 1

JL1

-TL2 Load 2

JL2

The node voltage in the circuit represents the mechanical speed m. The current probe on the left represents the reading of the Torque Sensor 1. Similarly, the current probe on the right represents the reading of the Torque Sensor 2. Note that the second current probe is from right to left since Sensor 2 is opposite to the reference direction of the mechanical system. The equivalent circuit also illustrates how mechanical power is transferred. The multiplication of the current to the voltage, which is the same as the torque times the mechanical speed, represents the mechanical power. If the power is positive, it is transferred in the direction of the speed m.

2.11.6 Position Sensors


Four types of position sensors are provided: absolute encoder, incremental encoder, resolver, and hall-effect position sensor. They are connected to the mechanical shaft, similar to the speed sensor and torque sensor, and the output signals are control signals.

Mechanical Elements and Sensors

107

2.11.6.1 Absolute Encoder


An absolute encoder is a position sensor that provides the shaft position within a 360o range (mechanical degree). Image:

Attribute: Parameter Initial Position (deg.) No. of Bits of Resolution Description Initial shaft position, in deg. Number of Bits of resolution N

The encoder output resolution is determined by the number of bits N. The encoder has two outputs: one is the number of counts (the range is from 0 to 2N-1), and the other is the position, in mechanical deg. (the range is from 0 to 360o). An example of a PMSM drive system using the absolute encoder is given in the sample file "Absolute Encoder PMSM Drive.sch".

2.11.6.2 Incremental Encoder


An incremental encoder is a position sensor that produces quadrature outputs which indicate the speed, angle, and direction of the shaft. Image:

108

Power Circuit Components

Attribute: Parameter Initial Position (deg.) No. of Lines Description Initial shaft position, in deg. Number of lines that are in the code pattern of the code disk of the encoder

The two quadrature outputs are A and A (A is the inverse of A), and B and B. They are offset by 90o. In addition, the encoder provides separate index signal output Z and Z that provide one count per revolution. An example of an induction motor drive system using the incremental encoder is given in the sample file "Incremental Encoder INDM Drive.sch".

2.11.6.3 Resolver
A resolver is essentially a rotary transformer with one rotor winding and two stator windings. These two stator windings, referring to as the COS winding and SIN winding, are located 90o apart. As the shaft rotates, the output voltages of the COS and SIN windings vary as the cosine and sine functions of the shaft angle. Image:

cos+ cos-

Attribute: Parameter Initial Position (deg.) No. of Poles Description Initial shaft position, in deg. Number of poles of the resolver

The resolver has four outputs: cos+, cos- (the inverse of cos+), sin+, and sin- (the inverse of sin+). The peak amplitude of all the outputs is 1.

sin+ sinMechanical Elements and Sensors

109

An example of a PMSM drive system using the resolver is given in the sample file "Resolver PMSM Drive.sch".

2.11.6.4 Hall-Effect Sensor


A hall-effect sensor is a type of position sensors that provides three pulses depending on the shaft position. The sensor consists of a set of semiconductor switches and trigger magnets. The switches open or close when the magnetic field is higher or lower than a certain threshold value. Image:

Attribute: Parameter Initial Position (deg.) No. of Poles Description Initial shaft position, in deg. Number of poles of the sensor

The hall-effect sensor provides three logic signal outputs A, B, and C, which are spaced 120 electrical deg. apart. The hall-effect sensor is the same as the built-in hall-effect sensor in the brushless dc machine. An example of a BDCM motor drive system using the hall-effect sensor is given in the sample file "Hall-Effect Sensor BDCM_Drive.sch".

110

Power Circuit Components

3
Control Circuit Components
3.1 Transfer Function Blocks
A transfer function block is expressed in polynomial form as:
B n s + ... + B 2 s + B 1 s + B 0 G ( s ) = k -----------------------------------------------------------------------------n 2 A n s + ... + A 2 s + A 1 s + A 0
n 2

Two types of transfer function blocks are provided: one with zero initial values (the element is called s-domain Transfer Function in the PSIM library) and the other with initial values as input parameters (called s-domain Transfer Function (1) in the PSIM library). Images:

Attributes: Parameters Order n Gain Coeff. Bn...Bo Coeff. An...Ao Initial Values xn..x1 Description Order n of the transfer function Gain k of the transfer function Coefficients of the numerator (from Bn to Bo) Coefficients of the denominator (from An to Ao) Initial values of the state variables xn to x1 (for the element s-domain Transfer Function (1) only)

Let Y(s) = G(s)*U(s) where Y(s) is the output and U(s) is the input, we can convert the sdomain expression into the differential equation form as follows:

Transfer Function Blocks

111

x1

0 0 0 ... 0 0 ... 0

A0 An A1 An

x1

B0 A0 Bn An

x2 1 0 d ---- x = 0 1 dt 3 ... ... ... xn 0 0

x2 B1 A1 Bn An k x + ----- u 0 ... 0 A 2 A n B2 A2 Bn An 3 An ... ... ... ... ... ... xn 0 ... 1 A n 1 A n Bn 1 An 1 Bn An

The output equation in the time domain can be expressed as:


Bn y = x n + k ----- u An

The initial values of the state variables xn to x1 can be specified as the inputs in the element s-domain Transfer Function (1). Example: The following is a second-order transfer function:
400.e G ( s ) = 1.5 --------------------------------------------------2 3 s + 1200 s + 400.e
3

In PSIM, the specification will be: Order n Gain Coeff. Bn...Bo Coeff. An...Ao 2 1.5 0. 0. 400.e3

1. 1200. 400.e3

3.1.1 Proportional Controller


The output of a proportional (P) controller is equal to the input multiplied by a gain. Image:

112

Control Circuit Components

Attribute: Parameter Gain Description Gain k of the transfer function

3.1.2 Integrator
The transfer function of an integrator is:
1 G ( s ) = ----sT

There are three types of integrators. regular integrator, external resettable integrator, and internal resettable integrator. Images:
Regular Integrator External Resettable Integrator Internal Resettable Integrator

Attributes: For Regular Integrator: Parameters Time Constant Initial Output Value Description Time constant T of the integrator, in sec. Initial value of the output

For External Resettable Integrator: Parameters Time Constant Initial Output Value Reset Flag Description Time constant T of the integrator, in sec. Initial value of the output Reset flag (0: edge reset; 1: level reset)

Transfer Function Blocks

113

For Internal Resettable Integrator: Parameters Time Constant Initial Output Value Lower Output Limit Upper Output Limit Description Time constant T of the integrator, in sec. Initial value of the output Lower limit of the output Upper limit of the output

The output of the external resettable integrator can be reset by an external control signal (at the bottom of the block). For the edge reset (reset flag = 0), the integrator output is reset to zero at the rising edge of the control signal. For the level reset (reset flag = 1), the integrator output is reset to zero as long as the control signal is high (1). The output of the internal resettable integrator is reset to 0 when the output reaches either the lower limit or the upper limit. It works in the same way as the external resettable integrator with the edge reset, except that in this case users do not need to set up the external reset circuit. To avoid over saturation, a limiter should be placed at the integrator output. Example: The following circuit illustrates the use of the resettable integrator. The input of the integrator is a dc quantity. The control input of the integrator is a pulse waveform which resets the integrator output at the end of each cycle. The reset flag is set to 0.

Vd

vo vctrl

114

Control Circuit Components

3.1.3 Differentiator
The transfer function of a differentiator is:
G ( s ) = sT

A differentiator is calculated as follows:


v in ( t ) v in ( t t ) v o ( t ) = T ------------------------------------------t

where t is the simulation time step, vin(t) and vin(t-t) are the input values at the present and the previous time step. Image:

Attribute: Parameter Time Constant Description Time constant T of the differentiator, in sec.

Since sudden changes of the input will generate spikes at the output, it is recommended that a low-pass filter be placed at the input of the differentiator.

3.1.4 Proportional-Integral Controller


The transfer function of a proportional-integral (PI) controller is defined as:
1 + sT G ( s ) = k -------------sT

Image:

Transfer Function Blocks

115

Attributes: Parameters Gain Time Constant Description Gain k of the PI controller Time constant T of the PI controller

To avoid over saturation, a limiter should be placed at the PI output.

3.1.5 Built-in Filter Blocks


Four second-order filters are provided as built-in modules in PSIM. Images:
Low-pass Filter High-pass Filter Band-pass Filter Band-stop Filter

Attributes: Parameters Gain Damping Ratio Cut-off Frequency Description Gain k Damping ratio
c Cut-off frequency fc ( f c = ----- ) for low-pass and high-

pass filters, in Hz Center Frequency Passing Band; Stopping Band

o Center frequency fo ( f o = ----- ) for band-pass and band-

stop filter, in Hz

B Frequency width fb ( f b = ----- ) of the passing/stopping

band for band-pass/band-stop filters, in Hz

The transfer function of these filters are listed below. For a second-order low-pass filter:
c G ( s ) = k -------------------------------------2 2 s + 2 c s + c
2

116

Control Circuit Components

For a second-order high-pass filter:


s G ( s ) = k -------------------------------------2 2 s + 2 c s + c
2

For a second-order band-pass filter:


Bs G ( s ) = k --------------------------------2 2 s + B s + o

For a second-order band-stop filter:


s + o G ( s ) = k --------------------------------2 2 s + B s + o
2 2

3.2

Computational Function Blocks

3.2.1 Summer
The input of a one-input summer or two-input summer can be either a scalar or a vector. The input of a three-input summer can only be a scalar. Images:
1-input
Input 1 Input 2

2-input
Input 1

2-input

3-input
Input 1 Input 2

Input 2

Input 3

Attribute: Parameter Gain_i Description Gain ki for the ith input

For the three-input summer, the input with a dot is the first input. If the inputs are scalar, the output of a summer with n inputs is defined as:
V o = k 1 V 1 + k 2 V 2 + ... + k n V n

If the input is a vector, the output of a two-input summer will also be a vector, which is defined as:

Computational Function Blocks

117

V1 = [a1 a2 ... an] V2 = [b1 b2 ... bn] Vo = V1 + V2 = [a1+b1 a2+b2 ... an+bn] The output of a one-input summer, however, will still be a scalar which is equal to the summation of the input vector elements, that is, Vo = a1 + a2 + ... an.

3.2.2 Multiplier and Divider


The output of a multipliers or divider is equal to the multiplication or division of two inputs. Images:
Multiplier
Numerator Denominator

Divider

For the divider, the dotted node is for the numerator input. The input of a multiplier can be either a vector or a scalar. If the two inputs are vectors, their dimensions must be equal. Let the two inputs be: V1 = [a1 a2 ... an] V2 = [b1 b2 ... bn] The output, which is a scalar, will be: Vo = V1 * V2T = a1*b1 + a2*b2 + an*bn

3.2.3 Square-Root Block


A square-root function block calculates the square root of the input. Image:

118

Control Circuit Components

3.2.4 Exponential/Power/Logarithmic Function Blocks


The images and attributes of these function blocks are shown below. Images:
Exponential Power LOG LOG10

Attributes (for exponential and power blocks): Parameters Coefficient k1 Coefficient k2 Description Coefficient k1 Coefficient k2
V V o = k 1 k 2 in

The output of an exponential function block is defined as: For example, if k1 = 1, k2 = 2.718281828, and Vin = 2.5, then Vo = e2.5 where e is the base of the natural logarithm. The output of a power function block is defined as:
k2 V o = k 1 V in

The function block LOG gives the natural logarithm (base e) of the input, and the block LOG10 gives the common logarithm (base 10) of the input.

3.2.5 Root-Mean-Square Block


A root-mean-square function block calculates the RMS value of the input over a period specified by the base frequency fb. The output is defined as:
V rms = 1 -T

0 vin ( t )dt

T 2

where T = 1/fb. The output is only updated at the beginning of each period. Image:

Computational Function Blocks

119

Attribute: Parameter Base frequency Description Base frequency fb, in Hz

3.2.6 Absolute and Sign Function Blocks


An absolute value function block gives the absolute value of the input. A sign function block (SIGN) gives the sign of the input, i.e., the output is 1 if the input is positive, and the output is -1 if the input is negative. Images:
Absolute Sign

3.2.7 Trigonometric Functions


Six trigonometric functions are provided: sine (sin), arc sine (sin-1), cosine (cos), arc cosine (cos-1), tangent (tan), and arc tangent (tg-1). The output is equal to the corresponding trigonometric function of the input. For the sin, cos, and tan blocks, the input is in deg., and for the sin-1, cos-1, and tg-1 blocks, the output is in deg. Images:

Imaginary Real

The dotted note of the arc tangent block is for the real input and the other node is for the imaginary input. The output is the arc tangent of the ratio between the imaginary and the
imaginary real input, i.e. = tg ----------------------- . V real 1

120

Control Circuit Components

3.2.8 Fast Fourier Transform Block


A Fast Fourier Transform block calculates the fundamental component of the input signal. The FFT algorithm is based on the radix-2/decimation-in-frequency method. The number of sampling points within one fundamental period should be 2N (where N is an integer). The maximum number of sampling points allowed is 1024. The output gives the amplitude (peak) and the phase angle of the input fundamental component. The output voltage (in complex form) is defined as:
N n = --- 1 2

2 v o = --- N

n=0

j --------- N N v in ( n ) v in n + --- e 2

2n

Image:
Amplitude Phase Angle

Attributes: Parameters No. of Sampling Points Fundamental Frequency Description No. of sampling points N Fundamental frequency fb, in Hz.

The dotted node of the block refers to the output of the amplitude. Note that the phase angle output has been internally adjusted such that a sine function Vm*sin(t) will give a phase angle output of 0. Example: In the circuit below, the voltage vin contains a fundamental component v1 (100 V at 60 Hz), a 5th harmonic voltage v5 (25 V at 300 Hz), and a 7th harmonic v7 (25 V at 420 Hz). After one cycle, the FFT block output reaches the steady state with the amplitude of 100 V and the phase angle of 0o.

Computational Function Blocks

121

v1 v5

vin

vamp Angle

v1 vin

v7

vamp
Angle

3.3

Other Function Blocks

3.3.1 Comparator
The output of a comparator is high when the positive input is higher than the negative input. When the positive input is lower, the output is zero. If the two input are equal, the output is undefined and it will keep the previous value. Image:

Note that the comparator image is similar to that of the op. amp. For the comparator, the noninverting input is at the upper left and the inverting input is at the lower left. For the op. amp., however, it is the opposite.

3.3.2 Limiter
The output of a limiter is clamped to the upper or lower limit whenever the input exceeds the limiter range. If the input is within the limit, the output is equal to the input. Image:

122

Control Circuit Components

Attributes: Parameters Lower Limit Upper Limit Description Lower limit of the limiter Upper limit of the limiter

3.3.3 Gradient (dv/dt) Limiter


A gradient (dv/dt) limiter limits the rate of change of the input. If the rate of change is within the limit, the output is equal to the input. Image:

Attribute: Parameter dv/dt Limit Description Limit of the rate of change (dv/dt) of the input

3.3.4 Trapezoidal and Square Blocks


Trapezoidal waveform blocks and square waveform blocks are specific types of lookup tables: the output and the input relationship is either a trapezoidal or a square waveform. Images:
Trapezoidal Waveform Square Waveform

For the trapezoidal waveform block: Attributes: Parameters Rising Angle theta Peak Value Description Rising angle , in deg. Peak value Vpk of the waveform

Other Function Blocks

123

For the square waveform block: Attribute: Parameter Pulse Width (deg.) Description Pulse width in half cycle, in deg.

The waveforms of these two blocks are shown below. Note that the input vin is in deg., and can be in the range of -360o to 360o. Both waveforms are half-wave and quarterwave symmetrical.
vo
Vpk

Trapezoidal Waveform
o o 360

vo

Square Waveform vin


o 180 o 360

1
180

0
-Vpk

vin

-1

3.3.5 Sampling/Hold Block


A sampling/hold block samples the input when the control signal changes from low to high (from 0 to 1), and holds this value until the next point is sampled. Image:
Input Control

The difference between this block and the zero-order hold block (ZOH) in Digital Control Module is that this block is treated as a continuous element and sampling moments can be controlled externally; whereas the zero-order hold block is a discrete element and the sampling moments are fixed and of equal distance. For a discrete system, the zero-order hold block should be used. Example: In this example, a sinusoidal input is sampled. The control signal is a square wave voltage source with an amplitude of 1.

124

Control Circuit Components

vin

vo vctrl

3.3.6 Round-Off Block


The image of a round-off block is shown below: Image:

Attributes: Parameters No. of Digits Truncation Flag Description No. of digits N after the decimal point Truncation flag (1: truncation; 0: round-off)

Let the input of the round-off block be Vin. The input is first scaled based on the following expression:
V in, new = V in 10
N

If the truncation flag is 1, the output will be equal to Vin,new truncated, and then divided by 10N. Otherwise, the output will be equal to Vin,new rounded off to the nearest integer, and then divided by 10N. Examples: If Vin = 34.5678; N = 0, truncation flag = 0, then we have the output Vout = 35. Similarly, if Vin = 34.5678; N = 0, truncation flag = 1, the output Vout = 34.

Other Function Blocks

125

If Vin = 34.5678; N = 1, truncation flag = 1, the output Vout = 34.5. If Vin = 34.5678; N = -1, truncation flag = 1, the output Vout = 30.

3.3.7 Time Delay Block


A time delay block delays the input waveform by a specified amount of time interval. It, for example. can be used to model the propagation delay of a logic element. Image:

Attribute: Parameter Time Delay Description Time delay, in sec.

Note that the difference between this block and the unit delay block (UDELAY) in Digital Control Module is that this block is a continuous element and the delay time can be arbitrarily set; whereas the unit delay block is a discrete element and the delay time is equal to the sampling period. For a discrete system, the unit delay block should be used. Example: In this circuit, the first time delay block has a delay time of 1 ms, and the second block has a delay time of 4 ms. This example illustrates that the input of the time delay block can be either an analog or a digital signal.
vin1 vin2
4 ms 1 ms

vo1 vo2

vin2

vo2

126

Control Circuit Components

3.3.8 Multiplexer
The output of a multiplexer is equal to a selected input depending on the control signal. Three multiplexers are provided: multiplexers with 2 inputs; 4 inputs; and 8 inputs. Images:
2-input 4-input 8-input

d0 d1 s0

d0 d1 d2 d3 s1 s0

d0
Y Y

d7 s2 s1 s0

In the images, d0..d7 are the data inputs; and s0..s2 are the control signals. The truth tables of the multiplexers are as follows. 2-Input MUX s0 Y 0 d0 1 d1 s1 0 0 1 1 4-Input MUX s0 Y 0 d0 1 d1 0 d2 1 d3 s2 0 0 0 0 1 1 1 1 8-Input MUX s1 s0 0 0 0 1 1 0 1 1 0 0 0 1 1 0 1 1 Y d0 d1 d2 d3 d4 d5 d6 d7

Note that the data input could be either an analog or digital signal. Example: The following circuit selects the maximum value out of two inputs. When Va is greater than Vb, the comparator output will be 1, and Vo = Va. Otherwise Vo = Vb.

Other Function Blocks

127

3.3.9 THD Block


The total harmonic distortion (THD) of an ac waveform that contains both the fundamental and harmonic components is defined as:
2 2 V rms V 1 Vh THD = ----- = -------------------------V1 V1

where V1 is the fundamental component (rms), Vh is the harmonic rms value, and Vrms is the overall rms value of the waveform. The THD block is modelled as shown below. Image:
THD THD vin(t) Circuit Model of the THD Block Vrms Vh THD

vin(t)

v1(t)

V1 v1(t)

A second-order band-pass filter is used to extract the fundamental component. The center frequency and the passing band of the band-pass filter need to be specified.

128

Control Circuit Components

Attributes: Parameters Fundamental Frequency Passing Band Example: In the single-phase thyristor circuit below, a THD block is used to measure the THD of the input current. The delay angle of the thyristor bridge is chosen as 30o. For the THD block, the fundamental frequency is set at 60 Hz and the passing band of the filter is set at 20 Hz. The simulation results are shown on the right. Description Fundamental frequency of the input, in Hz Passing band of the band-pass filter, in Hz

vs

alpha=30 deg.

is

THD

is1

One of the THD block output is the input current fundamental component is1. By comparing the phase difference between the input voltage vs and the current is1, one can calculate the input displacement power factor. This, together with the THD value, can be used to calculate the input power factor.

3.4

Logic Components

3.4.1 Logic Gates


Basic logic gates are AND, OR, XORGATE (exclusive-OR), NOT, NAND, and NOR gates.

Logic Components

129

Images:
AND OR NOT XOR

3-input AND

3-input OR

NAND

NOR

3.4.2 Set-Reset Flip-Flop


There are two types of set-reset flip-flops. One is edge-triggered and the other is leveltriggered. Image:

Attribute: Parameter Trigger Flag Description Trigger flag (0: edge-triggered; 1: level-triggered)

An edge-triggered flip-flop only changes the states at the rising edge of the set/reset input. The truth table of an edge-triggered flip-flop is: S 0 0

R 0

Q 0 1

Qn no change 1 0 not used

A level-triggered flip-flop, on the other hand, changes the states based on the input level. The truth table of a level-triggered set-reset flip-flop is:

130

Control Circuit Components

S 0 0 1 1

R 0 1 0 1

Q 0 1

Qn no change 1 0 not used

3.4.3 J-K Flip-Flop


A J-K flip-flop is positive edge-triggered. Image:

The truth table is: J 0 0 1 1 K 0 1 0 1 D


Q 0 1

Qn no change 1 0 Toggle

3.4.4 D Flip-Flop
A D flip-flop is positive edge-triggered. Image:

Logic Components

131

The truth table is: D 0 1 Clock


Q 0 1

Qn 1 0

3.4.5 Monostable Multivibrator


In a monostable multivibrator, the positive (or negative) edge of the input signal triggers the monostable. A pulse, with the specified pulse width, will be generated at the output. The output pulse width can be either fixed or adjusted through another input variable. The latter type of monostables is referred to as controlled monostables. Its on-time pulse width, in second, is determined by the control input. Images:
Monostable Controlled Monostable

Attribute: Parameter Pulse Width Description On-time pulse width, in sec.

The input node at the bottom of the controlled monostable block is for the pulse width input.

3.4.6 Pulse Width Counter


A pulse width counter measures the width of a pulse. The rising edge of the input activates the counter. At the falling edge of the input, the output gives the width of the pulse (in sec.). During the interval of two falling pulse edges, the pulse width counter output remains unchanged.

132

Control Circuit Components

Image:

3.4.7 Up/Down Counter


An up/down counter increments or decrements by 1 at each rising edge of the clock. Image:
Preset Enable Preset Value Clock Up/Down Reset Output

Attribute: Parameter No. of Bits Description Number of bits N

When the Up/Down input is 0, the counter decrements, and when the Up/Down input is 1, the counter increments. The Reset input resets the counter to 0 when it is high (1). The Preset Enable input sets the counter to the preset value when it is high. The truth table of the counter is: Up/Down x 1 0 x x x: Do not care Preset Enable 0 0 0 1 x Reset 0 0 0 0 1 Clock x

Action

No count
Count up Count down

x x

Preset Reset

Logic Components

133

3.4.8 A/D and D/A Converters


A/D and D/A converters perform analog-to-digital and digital-to-analog conversion. Both 8-bit and 10-bit converters are provided. Images:
ADC (8-bit) ADC (10-bit) DAC (8-bit)

Vref

Vref

DAC (10-bit)

Vin
Clock

Vo

Vin

Vo

Let N be the number of bits. The output of the A/D converter is calculated as:
2 V o = -------- V in V ref
N

For example, if Vref = 5 V, Vin = 3.2 V, N = 8 bits, then Vo = 256/5*3.2 = 163.84 = 10100011 (binary) The output of the D/A converter is calculated as:
V ref V o = -------- V in N 2

For example, if Vref = 5 V, Vin = 10100011 (binary) = 163, N = 8 bits, then Vo = 163/256*5 = 3.1836

134

Control Circuit Components

3.5

Digital Control Module


The Digital Control Module is an add-on module to the basic PSIM program. It provides discrete elements, such as zero-order hold, z-domain transfer function blocks, digital filters, etc., for digital control system simulation. In contrary to a s-domain circuit which is continuous, a z-domain circuit is discrete, and the calculation is only performed at the discrete sampling points. There is no calculation between two sampling points.

3.5.1 Zero-Order Hold


A zero-order hold samples the input at the point of sampling. The output remains unchanged between two sampling points. Image:

Attribute: Parameter Sampling Frequency Description Sampling frequency of the zero-order hold, in Hz

Like all other discrete elements, the zero-order hold has a free-running timer which determines the moment of sampling. The sampling moment is synchronized with the origin of the simulation time. For example, if the zero-order hold has a sampling frequency of 1000 Hz, the input will be sampled at 0, 1 msec., 2 msec., 3 msec., and so on. Example: In the following circuit, the zero-order hold sampling frequency is 1000 Hz. The input and output waveforms are shown on the left.

Digital Control Module

135

Note that in above circuit, a continuous-domain integrator is also connected to the input sine source. This makes it a mixed continuous-discrete circuit, and a simulation time step selected for the continuous circuit will be used. With this time step, the familiar staircase-like waveform can be observed at the zero-order hold output. Without the integrator, the circuit becomes a discrete circuit. Since only the calculation at the discrete sampling points is needed, the simulation time step will be equal to the sampling period, and only the results at the sampling points are available. The waveforms, as shown below, appear continuous. In fact the waveforms are discrete, and the connection between two sampling points makes it look like continuous.

3.5.2 z-Domain Transfer Function Block


A z-domain transfer function block is expressed in polynomial form as:
+ ... + b N 1 z + b N b0 z + b1 z H ( z ) = ------------------------------------------------------------------------------------------N N1 + ... + a N 1 z + a N a0 z + a1 z
N N1

If a0 = 1, the expression Y(z) = H(z) * U(z) can be expressed in difference equation as:

136

Control Circuit Components

y ( n ) = b 0 u ( n ) + b 1 u ( n 1 ) + ... + b N u ( n N ) [ a 1 y ( n 1 ) + a 2 y ( n 2 ) + ... + a N y ( n N ) ]

Image:

Attributes: Parameters Order N Coeff. b0...bN Coeff. a0...aN Sampling Frequency Example: The following is a second-order transfer function:
400.e H ( z ) = --------------------------------------------------2 3 z + 1200 z + 400.e
3

Description Order N of the transfer function Coefficients of the numerator (from b0 to bN) Coefficients of the denominator (from a0 to aN) Sampling frequency, in Hz

Assuming a sampling frequency of 3 kHz, the specification will be: Order N Coeff. b0...bN Coeff. a0...aN Sampling Frequency 2 0. 0. 400.e3

1. 1200. 400.e3 3000.

Digital Control Module

137

3.5.2.1 Integrator
There are three types of integrators: regular integrator, external resettable integrator, and internal resettable integrator. Images:
Regular Integrator External Resettable Integrator Internal Resettable Integrator

Attribute: Parameters Algorithm Flag Description Flag for integration algorithm 0: trapezoidal rule 1: backward Euler 2: forward Euler Initial Output Value Reset Flag Lower Output Limit Upper Output Limit Sampling Frequency Initial output value Reset flag (0: edge reset; 1: level reset) (for external resettable integrator only) Lower limit of the output (for internal resettable integrator only) Upper limit of the output (for internal resettable integrator only) Sampling frequency, in Hz

The output of an external resettable integrator can be reset by an external control signal (at the bottom of the block). With the edge reset (reset flag = 0), the integrator output is reset to zero at the rising edge of the control signal. With the level reset (reset flag = 1), the integrator output is reset to zero as long as the control signal is high (1). The output of an internal resettable integrator is reset to 0 whenever the output reaches either the lower limit or the upper limit. The integrator works in the same way as the external resettable integrator with the edge reset, except that users do not need to set up the external reset circuit in this case. If we define u(t) as the input, y(t) as the output, T as the sampling period, and H(z) as the discrete transfer function, the input-output relationship of an integrator can be expressed

138

Control Circuit Components

under different integration algorithms as follows. With trapezoidal rule:


T z+1 H ( z ) = -- ---------2 z1 T y ( n ) = y ( n 1 ) + -- ( u ( n ) + u ( n 1 ) ) 2

With backward Euler:


z H ( z ) = T ---------z1 y(n) = y( n 1) + T u(n)

With forward Euler:


1H ( z ) = T ---------z1 y(n) = y(n 1) + T u(n 1)

3.5.2.2 Differentiator
The transfer function of a discrete differentiator is:
1 z1 H ( z ) = -- ---------T z

where T is the sampling period. The input-output relationship can be expressed in difference equation as:
1 y ( n ) = -- ( u ( n ) u ( n 1 ) ) T

Image:

Digital Control Module

139

Attribute: Parameter Sampling Frequency Description Sampling frequency, in Hz

3.5.2.3 Digital Filters


Two types of digital filters are provided: general digital filter and finite impulse response (FIR) filter. For both types, the filter coefficients can either be entered directly through the element property window, or be specified through a text file. Images:
General Digital Filter FIR Filter

Attributes: For elements that read the coefficients directly: Parameters Order N Coeff. b0...bN Coeff. a0...aN Sampling Frequency Description Order N of the transfer function Coefficients of the numerator (from b0 to bN) Coefficients of the denominator (from a0 to aN) Sampling frequency, in Hz

For elements that read the coefficients from a text file: Parameters File for Coefficients Sampling Frequency Description Name of the file storing the filter coefficients Sampling frequency, in Hz

The transfer function of the general digital filter is expressed in polynomial form as:
+ bN z b 0 + b 1 z + ... + b N 1 z H ( z ) = ------------------------------------------------------------------------------------------------------1 ( N 1 ) N + aN z a 0 + a 1 z + ... + a N 1 z
1 ( N 1 ) N

140

Control Circuit Components

If a0 = 1, the output y and input u can be expressed in difference equation form as:
y ( n ) = b 0 u ( n ) + b 1 u ( n 1 ) + ... + b N u ( n N ) [ a 1 y ( n 1 ) + a 2 y ( n 2 ) + ... + a N y ( n N ) ]

If the denominator coefficients a0..aN are not zero, this type of filter is called infinite impulse response (IIR) filter. The transfer function of the FIR filter is expressed in polynomial form as:
H ( z ) = b0 + b1 z
1

+ ... + b N 1 z

( N 1 )

+ bN z

If a0 = 1, the output y and input u can be expressed in difference equation form as:
y ( n ) = b 0 u ( n ) + b 1 u ( n 1 ) + ... + b N u ( n N )

The coefficient file for block FILTER_D1 and FILTER_FIR1 has the following format: For Filter_FIR1: N b0 b1 ... ... ... bN For Filter_D1, the format can be either one of the following: N b0 b1 ... ... ... bN a0 a1 ... ... ... aN or N b0, a0 b1, a1 ... ... ... bN, aN

Digital Control Module

141

Example: To design a 2nd-order low-pass Butterworth digital filter with the cut-off frequency fc = 1 kHz, assuming the sampling frequency fs = 10 kHz, using MATLAB, we have: Nyquist frequency fn = fs / 2 = 5 kHz Normalized cut-off frequency fc* = fc/fn = 1/5 = 0.2 [B,A] = butter (2, fc*) which will give: B = [0.0201 0.0402 0.0201 ] = [b0 b1 b2] A=[ 1 -1.561 0.6414 ] = [a0 a1 a2] The transfer function is:
0.0201 + 0.0402 z + 0.0201 z H ( z ) = -----------------------------------------------------------------------------------1 2 1 1.561 z + 0.6414 z
1 2

The input-output difference equation is:


y ( n ) = 0.0201 u ( n ) + 0.0402 u ( n 1 ) + 1.561 y ( n 1 ) 0.6414 y ( n 2 )

The parameter specification of the filter in PSIM will be: Order N Coeff. b0...bN Coeff. a0...aN Sampling Frequency 2 0.0201 1. 10000. 0.0402 -1.561 0.0201 0.6414

If the coefficients are stored in a file, the file content will be: 2 0.0201 0.0402 0.0201 1. -1.561 0.6414 Or the file can also have the content as follows:

142

Control Circuit Components

2 0.0201, 1 0.0402, -1.561 0.0201, 0.6414

3.5.3 Unit Delay


A unit delay block provides one sampling period delay to the input. Image:

Attribute: Parameter Sampling Frequency Description Sampling frequency, in Hz

The difference between a unit delay block and a time delay block (TDELAY) is that the unit delay block is a discrete element and it delays the sampled points by one sampling period, whereas TDELAY is a continuous element and it delays the whole waveform by the delay time specified.

3.5.4 Quantization Block


A quantization block simulates the quantization error during an A/D conversion. Image:

Attributes: Parameters No. of Bits Vin_min Vin_max Description Number of bits N Lower limit of the input value Vin,min Upper limit of the input value Vin,max

Digital Control Module

143

Vo_min Vo_max Sampling Frequency

Lower limit of the output value Vo,min Upper limit of the output value Vo,max Sampling frequency, in Hz

A quantization block performs two functions: scaling and quantization. The input value Vin, sampled at the given sampling frequency, is first scaled based on the following:
V in V in, min V ox = V in, min + -------------------------------------- ( V o, max V o, min ) V in, max V in, min

The number of bits determines the output resolution V which is defined as:
V o, max V o, min V = ----------------------------------N 2 1

The output Vo will be equal to the truncated value of Vox based on the resolution V. Example: If N = 4, Vin,min = 0, Vin,max = 10, Vo,min = -5, Vo,min = 5, and Vin = 3.2, then: Vox = -5 + (3.2 - 0) * (5 - (05)) / (10 - 0) = -1.8 V = (5 - (-5)) / (24 - 1) = 0.66667 The value -1.8 is between -2.33332 and -1.66665. Therefore, the lower value is selected, that is, Vo = -1.66665.

3.5.5 Circular Buffer


A circular buffer is a memory location that can store an array of data. Image:

144

Control Circuit Components

Attributes: Parameters Buffer Length Sampling Frequency Description The length of the buffer Sampling frequency, in Hz

A circular buffer stores data in a buffer. When the pointer reaches the end of the buffer, it will start again from the beginning. The output of the circular buffer is a vector. To access to each memory location, use the memory read block MEMREAD. Example: If a circular buffer has a buffer length of 4 and a sampling frequency of 10 Hz, we have the buffer storage at different time as follows: Value at Memory Location Time 0 0.1 0.2 0.3 0.4 ... ... ... Input 0.11 0.22 0.33 0.44 0.55 1 0.11 0.11 0.11 0.11 0.55 2 0 0.22 0.22 0.22 0.22 3 0 0 0.33 0.33 0.33 4 0 0 0 0.44 0.44

3.5.6 Convolution Block


A convolution block performs the convolution of two input vectors. The output is also a vector. Image:

Let the two input vectors be: A = [ am am-1 am-2 ... a1]

Digital Control Module

145

B = [ bn bn-1 bn-2 ... b1] We have the convolution of A and B as:


C = AB

= [cm+n-1 cm+n-2 ... c1]


where ci = [ ak+1 * bj-k], k=0, ..., m+n-1; j=0, ..., m+n-1; i=1, ..., m+n-1

Example: If A = [1 2 3] and B = [4 5], we have m = 3; n = 2; and the convolution of A and B is: C = [4 13 22 15].

3.5.7 Memory Read Block


A memory read block is used to read the value of a memory location of a vector. Image:

Attribute: Parameter Memory Index Offset Description Offset from the starting memory location

A memory read block allows one to access the memory location of elements such as convolution block, vector array, and circular buffer. The index offset defines the offset from the starting memory location. Example: Let a vector be A = [2 4 6 8]. If index offset is 0, the memory read block output will be 2. If the index offset is 2, the output will be 6.

3.5.8 Data Array


This is a one-dimensional array. The output is a vector. The data are either entered directly (the element is called Array in the PSIM library) or specified in a file (the element is called Array (1) in the PSIM library).

146

Control Circuit Components

Image:

Attributes: Parameters Array Length Values File for Coefficients Description The length of the data array N (for the element Array only) Values of the array (for the element Array only) Name of the file storing the array (for the element Array (1) only)

If the array is read from a file, the file will have the following format: N a1 ... ... ... aN where N is the length of the array, and a1..aN are the array values. Example: To define an array A = [2 4 6 8], we will have: Array Length = 4; Values = 2 4 6 8. If the array is to be read from a file, the file will be: 4 2. 4. 6. 8.

Digital Control Module

147

3.5.9 Stack
A stack is a first-in-last-out register. Image:
Vin push pop

Vo

Attribute: Parameter Stack Depth Description The stack depth

The rising edge triggers the push or pop action. When a pop action is performed and the stack is empty, the output remains unchanged. When a push action is performed and the stack is already full, the data at the bottom of the stack will be pushed out and will be lost.

3.5.10 Multi-Rate Sampling System


A discrete system can have more than one sampling rate. The following system is used to illustrate this. The system below has 3 sections. The first section has a sampling rate of 10 Hz. The output, Vo, fed back to the system and is sampled at 4 Hz in the second section. In the third section, the output is displayed at a sampling rate of 2 Hz. It should be noted that a zero-order hold must be used between two elements with different sampling rates.

148

Control Circuit Components

Vo

Digital Control Module

149

3.6

SimCoupler Module
The SimCoupler Module is an add-on module to the basic PSIM software. It provides interface between PSIM and Matlab/Simulink for co-simulation. With the SimCoupler Module, part of a system can be implemented and simulated in PSIM, and the rest of the system in Simulink. One can therefore make full use of PSIMs capability in power simulation and Matlab/Simulinks capability in control simulation in a complementary way. The SimCoupler interface consists of two parts: the link nodes in PSIM, and the SimCoupler model block in Simulink. The images are shown below. Images:
In PSIM SLINK_IN SLINK_OUT In SimuLink SimCoupler Model Block

In PSIM, the SLINK_IN nodes receive values from Simulink, and the SLINK_OUT nodes send the values to Simulink. They are all control elements and can be used in the control circuit only. In Simulink, the SimCoupler model block is connected to the rest of the system through input/output ports.

3.6.1 Set-up in PSIM and Simulink


The use of the SimCoupler Module is easy and straightforward. As an example, the following shows a permanent-magnet synchronous motor (PMSM) drive system with the power stage implemented in PSIM, and the control in Simulink.

150

Control Circuit Components

Power in PSIM File: pmsm_psim.sch

Control in SimuLink File: pmsm_simulink.mdl

The following are the steps to set up SimCoupler for PSIM-Matlab/Simulink cosimulation for the example above. Adding the SimCoupler Block to the Simulink Library: Run the program "SetSimPath.exe" to add the SimCoupler block to the Simulink library and set up the SimCoupler Module for co-simulation of PSIM and Matlab/Simulink. After the execution, the SimCoupler block will appear as "S-function SimCoupler" in the Simulink Library Browser. Note that this step is necessary, otherwise Simulink will not be able to find PSIM. With this, it is also not necessary to manually add the PSIM folder to the Matlab path. Also, this program needs to be run only once. It needs to be run again only if the PSIM folder or Matlab folder has changed.

SimCoupler Module

151

In PSIM: - After the rest of the power circuit is created, connect three SLINK_OUT nodes to the low-pass filters of Phase A, B, and C currents, and rename them as Ia, Ib, and Ic; and connect one SLINK_OUT node to the speed sensor output and rename it as Wrpm. - Connect three SLINK_IN nodes to the positive inputs of the comparators, and rename them as Va, Vb, and Vc. - Go to the Simulate menu, and select Arrange SLINK Nodes. A dialog window will appear. Arrange the order of the SLINK_IN nodes and SLINK_OUT nodes to be the same as how the input/output ports would appear in the SimCoupler model block in Simulink (the order of the ports is from the top to the bottom). In this example, the order will be Va, Vb, and Vc for the SLINK_IN nodes, and Ia, Ib, Ic, and Wrpm for the SLINK_OUT nodes. - Save the schematic file. In this example, we assume that the file is saved to C:\PSIM\pmsm_psim.sch. In Simulink: - Start Matlab. - Launch Simulink. Open an existing file or create a new file. After the rest of the system is created, go to the menu "S-function SimCoupler" in the Simulink Library Browser, select the SimCoupler block, and place it on the schematic. - In the PMSM example file, double click on the SimCoupler block, and click on the Browser button to locate and select the PSIM schematic file C:\PSIM\pmsm_psim.sch. Then click on Apply. The number of input and output ports of the SimCoupler model block will automatically match those defined in the PSIM netlist. In this case, there will be 3 input ports and 4 output ports. - Go to the Simulation menu and select Simulation Parameters. Under Solver Options, set the Type to Fixed-step. Set Fixed step size to be the same as or close to PSIMs time step. In this case, the time step is set to 0.1ms. More discussion on the selection of the solver option and the time step is given in the next section. - The setup is now complete. Go to Simulink and start the simulation. The SimCoupler Module supports Matlab/Simulink Release 13 and 14. Please also note that when the SimCoupler model block is used in a feedback system in Simulink, the SimCoupler model block may be part of an algebraic loop (please refer to

152

Control Circuit Components

Matlab Help for more information on algebraic loops). Some versions of Matlab/ Simulink can not solve a system containing algebraic loops, and other can solve the system but with degraded performance. To break an algebraic loop, place a memory block at each output of the SimCoupler model block. The memory block introduces one integration time step delay.

3.6.2 Solver Type and Time Step Selection in Simulink


There are certain restrictions on the selection of the solver type and the time step in Simulink when performing the co-simulation. To illustrate this, we use the following one-quadrant chopper circuit with average current mode control as an example. The circuit on the left is all implemented and simulated in PSIM. The circuit on the right has the power stage implemented in PSIM, and the control implemented in Simulink. In both circuits, the PSIM simulation time step is 2 us.
Complete circuit in PSIM Power circuit in PSIM

Time step: 2us

There are different ways of setting up Simulink to perform co-simulation. The recommend approach is to set the Solve Type to Fixed-step and define the Fixed step size to be the same or close to PSIMs time step. The figure below shows this option.

SimCoupler Module

153

Control in Simulink

Solver Type: Fixed-step Time step: 20 us

It is recommended that Simulink use the same time step as PSIM, although we have found that, even if the Simulink time step is slightly larger than PSIM time step, satisfactory results are obtained. In this case, for example, the time step is set to 20 us, 10 times larger than the PSIM time step. If the Simulink Solver type is instead set to Variable-step, the simulation results will not be correct. The figure below shows this option.
Control in Simulink Solver Type: Variable-step

When the Simulink Solver type is set to Variable-step, in order to obtain correct results, a zero-order-hold must be placed at the input of the SimCoupler model block. Moreover, the zero-order-hold sample time must be the same or close to PSIM time step. The figure below shows the configuration.

154

Control Circuit Components

Control in Simulink

Solver Type: Variable-step ZOH Sample Time: 2 us

Therefore, Simulink must be set up to have the Solver Type as Fixed-step with the time step the same or close to the PSIM time step, or if the Solver Type is Variable-step, a zero-order-hold must be used with the sample time the same or close to PSIM time step

SimCoupler Module

155

156

Control Circuit Components

4
Other Components
4.1 Parameter File
The parameter file element .FILE defines the name of the file that stores the component parameters and limit settings. For example, the resistance of a resistor can be specified as R1, and the value of R1 is defined in the parameter file. Image:

The parameter file is a text file created by the user. The format is shown below: <name> = <value> <name> <value> LIMIT <name> <lower limit> <upper limit> % A comment line The field <value> can be either a numerical number (e.g. R1 = 12.3) or a mathematical expression (e.g. R3 = R1 + R2/2.). The name and the value can be separated by either an equation sign (e.g. R1 = 12.3) or a space (e.g. R1 12.3). Text from the character % to the end of the line is treated as comments (e.g. % R3 is the load resistance). For example, a parameter file may look like the following: R1=12.3 R2 23.4Ohm R3=R1+R2/2. L1=3m C1=100uF [R1 is defined as 12.3] [Equation sign can be replaced by space] [This line is comments] [Math expression is allowed] [power-of-ten suffix is allowed. L1=0.003]

% R3 is the load resistance

Parameter File

157

LIMIT R3 5. 25.

[R3 is limited between 5. and 25.]

4.2

Sources
Several types of independent voltage/current sources are available in PSIM. The notation of a current source direction is: the current flows out of the higher-potential node, through the external circuit, and back into the lower-potential node of the source. Note that current sources can be used in the power circuit only.

4.2.1 Time
The Time element is a special case of the piecewise linear voltage source. It is treated as a grounded voltage source, and the value is equal to the simulation time, in sec. Image:

4.2.2 DC Source
A dc source has a constant amplitude. The reference of the grounded dc voltage sources is the ground. Images:
DC DC (battery) Grounded DC Grounded DC (1) Current

Attribute: Parameter Amplitude Description Amplitude of the source

158

Other Components

4.2.3 Sinusoidal Source


A sinusoidal source is defined as:
v o = V m sin ( 2 f t + ) + V offset

The specifications can be illustrated as follows.


Vm Voffset t

1/f

Images:
Voltage Current

Attributes: Parameters Peak Amplitude Frequency Phase Angle DC Offset Tstart Description Peak amplitude Vm Frequency f, in Hz Initial phase angle , in deg. DC offset Voffset Starting time, in sec. Before this time, the source is 0.

To facilitate the setup of three-phase circuits, a symmetrical three-phase Y-connected sinusoidal voltage module is provided. The dotted phase of the module refers to Phase A.

Sources

159

Image:
3-phase Voltage

a b c

Attributes: Parameters V (line-line-rms) Frequency Init. Angle (phase A) Description Line-to-line rms voltage amplitude Frequency f, in Hz Initial angle for Phase A

4.2.4 Square-Wave Source


A square-wave voltage source or current source is defined by peak-to-peak amplitude, frequency, duty-cycle, and DC offset. The duty cycle is defined as the ratio between the high-potential interval versus the period. Images:
Voltage Current

160

Other Components

Attributes: Parameters Vpeak-peak Frequency Duty Cycle DC Offset Phase Delay Description Peak-to-peak amplitude Vpp Frequency, in Hz Duty cycle D of the high-potential interval DC offset Voffset Phase delay of the waveform, in deg.

The specifications of a square wave source are illustrated as follows.


Vpp D*T 0 T (T=1/f) Voffset t

When the phase delay is positive, the waveform is shifted to the right along the time axis.

4.2.5 Triangular Source


A triangular-wave voltage source (VTRI) or current source (ITRI) is defined by peakto-peak amplitude, frequency, duty-cycle, and DC offset. The duty cycle is defined as the ratio between the rising-slope interval versus the period. Images:
Voltage Current

Sources

161

Attributes: Parameters Vpeak-peak Frequency Duty Cycle DC Offset Phase Delay Description Peak-to-peak amplitude Vpp Frequency, in Hz Duty cycle D of the rising slope interval DC offset Voffset Phase delay of the waveform, in deg.

The specifications of a triangular wave source are illustrated as:


D*T Vpp

0 T (T=1/f)

Voffset

When the phase delay is positive, the waveform is shifted to the right along the time axis.

4.2.6 Step Sources


A step voltage/current source changes from one level to another at a given time. Two types of step sources are provided: one that changes from 0 to a certain level (refer to as Step in the library), and the other that changes from one level to another level (referred to as Step (1) in the library). Images:
Voltage Current

162

Other Components

Attributes: For the Step type source: Parameters Vstep Tstep Description Value Vstep after the step change Time Tstep at which the step change occurs

For the Step (1) type source: Parameters Vstep1 Vstep2 Tstep T_transition Description Value Vstep1 before the step change Value Vstep2 after the step change Time Tstep at which the step change occurs Transition time Ttransition from Vstep1 to Vstep2

The specifications of the voltage step sources are illustrated as follows:


Step Type Step (1) Type

Vstep Vstep1

Vstep2 Ttransition

Tstep

Tstep

4.2.7 Piecewise Linear Source


The waveform of a piecewise linear source consists of piecewise linear segments. It is defined by the number of points, the values and the corresponding time (in sec.). The values and times can be entered either separately, or in pair. Images:
Voltage Current

Sources

163

Attributes: For the sources that define the values and times separately: Parameters Frequency No. of Points n Values V1...Vn Time T1...Tn Description Frequency of the waveform, in Hz No. of points Values at each point Time at each point, in sec.

For the sources that define the values and times in pair: Parameters Frequency Times, Values (t1,v1) ... Description Frequency of the waveform, in Hz Time and value at each point

The time and value pair must be enclosed by left and right brackets. The time and value can be separated by either a comma, such as (1.2m,5.5), or a space, such as (1.2m 5.5), or both, such as (1.2m, 5.5). Example: The following is a non-periodic piecewise linear source. It has 3 segments which can be defined by four points (marked in the figure).
3 2 1 0 0.1 0.2 Time (sec.) 0.3

The specification for the piecewise linear voltage source will be: Frequency No. of Points n Values V1...Vn Times T1...Tn 0. 4 1. 1. 3. 3. 0. 0.1 0.2 0.3

164

Other Components

The specification for the piecewise linear (1) voltage source will be: Frequency Times, Values (t1,v1)... 0. (0., 1) (0.1, 1) (0.2, 3) (0.3, 3)

4.2.8 Random Source


The amplitude of a random voltage source (VRAND) or current source (IRAND) is determined randomly at each simulation time step. A random source is defined as:
v o = V m n + V offset

where Vm is the peak-to-peak amplitude of the source, n is a random number in the range of 0 to 1, and Voffset is the dc offset. Images:
Voltage Current

Attributes: Parameters Peak-Peak Amplitude DC Offset Description Peak-to-peak amplitude of the source DC offset

4.2.9 Math Function Source


A math function source allows one to define the source in a mathematical expression. Image:

Sources

165

Attributes: Parameters Expression Tstart Description The mathematical expression of the source Start time of the source

In the expression, T or t represents time. For example, to implement a sinusoidal source, the expression will be: sin(2*3.14159*60*t+2.09).

4.2.10 Voltage/Current-Controlled Sources


The following types of controlled sources are available: - Voltage controlled voltage source - Current controlled voltage source - Voltage controlled current source - Current controlled current source - Variable-gain voltage controlled voltage source - Variable-gain voltage controlled current source The controlling current of a current controlled source must come from a RLC branch. Also, for a controlled current source, the controlling voltage or current can not be an independent source. Note that controlled sources can be used in the power circuit only. Images:
Voltage-controlled Current-controlled Current-controlled (1) Variable-gain voltage-controlled
vin1 vin2

Voltage-controlled

Current-controlled

Current-controlled (1)

Variable-gain voltage-controlled
vin1 vin2

166

Other Components

Attribute: Parameter Gain Description Gain of the source

For voltage-controlled sources, the controlling voltage is from the positive node (+) to the negative node (-). For current-controlled sources (with an arrow pointing from one node to another), the control nodes are connected across a RLC branch, and the direction of the controlling current is indicated by the arrow. For current-controlled sources (with a wire connecting the two nodes), the controlling current flows from one control node to another, as indicated by the arrow. A 10-uOhm resistor is used to sense the controlling current. The output of a controlled source, except variable-gain controlled sources, is equal to the gain multiplied by the controlling voltage or current. For the variable-gain controlled sources, the output is equal to the following:
v o = ( k v in2 ) v in1 i o = ( k v in2 ) v in1

Input 1 is on the side with the multiplication sign, and Input 2 is on the side with the letter k. The difference between a variable-gain controlled source and a nonlinear source with multiplication is that, for the nonlinear source with multiplication, values of both vin1 and vin2 at the current time step are used to calculate the output and are updated in each iteration. But for the variable-gain controlled source, it is assumed that the change of vin2 is small from one time step to the next, and the value of vin2 at the previous time step is used at the current time step. This assumption is valid as long as vin2 changes at a much slower rate as compared to vin1 and the time step is small as compared to the change of vin2. Variable-gain controlled sources can be used in circuits which may otherwise have convergence problem with nonlinear sources with multiplication. Example: The circuits below illustrates the use of current controlled voltage sources. In the circuit on the left, the voltage source is controlled by the inductor current is. With a gain of 1, the waveform of the voltage vis is equal to that of is. In this way, a current quantity can be converted to a voltage quantity.

Sources

167

The circuit on the right is equivalent to that on the left, except that a different current controlled source is used instead.
Vis Vis

is

is

4.2.11 Nonlinear Voltage-Controlled Sources


The output of a nonlinear voltage-controlled source is either the multiplication, division, or square-root of the inputs. They are defined as: Nonlinear (multiplication): Nonlinear (division): Nonlinear (square-root): Nonlinear (power): Output v o = k v in1 v in2 or i o = k v in1 v in2
in1 in1 Output v o = k -------- or i o = k --------

v v in2

v v in2

Output v o = k v in1 or i o = k v in1 Output v o = sign ( v in ) k ( k 1 v in )


k2

In the nonlinear power source, the term sign(vin) is 1 if vin is positive, and it is -1 if vin is negative. Note that these nonlinear sources can be used in the power circuit only. Images:
Multiplication
vin1

Division
vin2

Square-root

Power

vin1

vin2

168

Other Components

Attributes: For all the sources except the nonlinear power source: Parameter Gain Description Gain k of the source

For the nonlinear power source: Parameters Gain Coefficient k1 Coefficient k2 Description Gain k of the source Coefficient k1 Coefficient k2

For the nonlinear (division) source, Input 1 is on the side of the division sign.

4.3

Voltage/Current Sensors
Voltage/current sensors measure the voltages/currents of the power circuit and send them to the control circuit. The current sensor has an internal resistance of 1 . Images:
VSEN ISEN

Attribute: Parameter Gain Description Gain of the sensor

4.4

Probes and Meters


Probes and meters are used to measure voltages, currents, power, or other quantities. A voltage probe (VP) measures a node voltage with respect to ground. A two-terminal voltage probe (VP2) measures the voltage between two nodes. A current probe (IP) measures the current through the probe. Note that all the probes and meters, except the node-to-ground probe VP, are allowed in the power circuit only.

Voltage/Current Sensors

169

While probes measure a voltage or current quantity in its true form, meters can be used to measure the dc or ac voltage/current, or the real power and reactive power. These meters function in the same way as the actual meters. A small resistor of 1 is used in the current probe internally to measure the current. Images:
Voltage Probe Current Probe DC Voltmeter AC Voltmeter DC Ammeter AC Ammeter

Wattmeter

VAR Meter

3-phase Wattmeter

3-phase VAR Meter

VA-Power Factor Meter

3-phase VA-Power Factor Meter

Attributes: Parameters Operating Frequency Cut-off Frequency VA Display Flag PF Display Flag DPF Display Flag Description Operating frequency or fundamental frequency of the ac meter, in Hz Cut-off frequency of the low-pass/high-pass filter, in Hz Display flag for apparent power (0: no display; 1: display) Display flag for power factor (0: no display; 1: display) Display flag for displacement power factor (0: no display; 1: display)

A low-pass filter is used in the dc meter and wattmeter models to filter out highfrequency components, whereas a high-pass filter is used in the ac meter and VAR meter

170

Other Components

models to filter out the dc component. The cut-off frequency determines the transient response of the filter. Except the voltage and current probes, the readings of all the meters are meaningful only when the readings reach the steady state. For the single-phase VA-Power Factor meter, the apparent power (S), total power factor (PF), and the displacement power factor (DPF) are defined as follows. Assume both the voltage and current contains harmonics, i.e.
v(t) = i(t) = 2V 1 sin ( 1 t + 1 ) + 2V 2 sin ( 2 t + 2 ) + ... 2I 1 sin ( 1 t + 1 ) + 2I 2 sin ( 2 t + 2 ) + ...

where 1 is the fundamental frequency and all others are harmonic frequencies. We have the rms values of the voltage and current as:
V rms = I rms = V 1 + V 2 + ... I 1 + I 2 + ...
2 2 2 2

The apparent power is defined as:


S = V rms I rms

The real power (or average power) is defined as:


1 P = -T

0 ( v ( t ) i ( t ) ) dt

where T is the fundamental period. The total power factor PF and the displacement power factor DPF are then defined as follow:
P PF = -S DPF = cos ( 1 1 )

For the three-phase circuit, the definitions are similar. Note that the meter VA_PF3 is for the 3-phase 3-wire circuit, and the summation of the three phase voltages or currents must be equal to zero, that is:

Probes and Meters

171

va + vb + vc = 0 ia + ib + ic = 0

4.5

Voltage/Current Scopes
While voltage/current probes and meters save the simulation results for post waveform processing, voltage/current scopes allow users to view simulation waveforms at runtime in the middle of the simulation. Three scopes are provided: 1-channel voltage scope, 2-channel voltage scope, and current scope. Below are the images of the voltage and current scopes and their expanded view.
2-channel voltage scope 1-channel voltage scope Current scope

The 1-channel voltage scope and the current scope have the same interface. The scope is designed to operate in a similar way as the actual oscilloscope in the lab. It has 3 main sections: Timebase section, Channel section, and Trigger section. In the Timebase section, the scale of time (x axis) is defined. In the Channel section, the scale of the Y axis, as well as the offset and the color of the

172

Other Components

waveform, are defined. In the Trigger section, the trigger conditions are defined. The trigger can be set to either ON or OFF. When the trigger is off, the waveform is free-running, and the display of the waveform in the scope may vary from one frame to another. If the trigger is on, the waveform display will only start when the trigger conditions are met. This will lead to a steady waveform display. There are three trigger modes: rising-edge triggering, falling-edge triggering, and oneshot triggering (if the once checkbox is checked, the one-shot triggering is selected). The one-shot triggering will trigger only once, and it is useful, for example, in situations where a transient needs to be captured. The trigger level sets the level at which the triggering occurs. For example, if Channel A is selected with the rising-edge triggering and the trigger level of 0V, whenever the Channel A input crosses over 0 from negative to positive, triggering will occur and the waveform display will start from that instant. Note that voltage scopes have connecting terminals which can be connected to either power circuit nodes or control circuit nodes. The scopes will display the node-to-ground voltages at these nodes. The current scope, on the other hand, has no connecting terminals. It is associated with any element that has the parameter of the current flag, and it is enabled by right clicking on top of the element, and selecting the branch current under the Current Scopes, as shown below. After the branch current is selected, a check mark will appear in front of the branch current name.

Voltage/Current Scopes

173

If the element has multiple current flags, under the Current Scopes menu, there will be multiply branch currents, one corresponding to each current flag. For example, for a 3-phase resistor R1, under the Current Scopes menu, there will be three branch currents: I(R1) A I(R1) B I(R1) C The letter "A", "B", and "C" refer to Channel A, B, and C, respectively. For example, if "I(R1) A", "I(R1) B", and "I(R1) C) are all selected, in the current scope, one can go to the Channel pull-down menu in the Channel section, and select one of the channels for display. If Channel A is selected, the scope will show the Phase A branch current I(R1).

4.6

Switch Controllers
A switch controller has the same function as a switch gate/base drive circuit in an actual circuit. It receives the input from the control circuit, and controls switches in the power circuit. One switch controller can control multiple switches simultaneously.

4.6.1 On-Off Switch Controller


On-off switch controllers are used as the interface between control gating signals and power switches. The input, which is a logic signal (either 0 or 1) from the control circuit, is passed to the power circuit as the gating signal. Image:

Example: The circuit below implements the step change of a load. In the circuit, the on-off switch controller is used to control the bi-directional switch. The step voltage source, which is connected to the controller input, changes from 0 to 1 at the time of 12 ms. The closure of the switch results in the short-circuit of the resistor across the switch and the increase of the current.

174

Other Components

On-off Controller

4.6.2 Alpha Controller


An alpha controller is used for delay angle control of thyristor switches or bridges. There are three input for the controller: the alpha value, the synchronization signal, and the gating enable/disable signal. The transition of the synchronization signal from low to high (from 0 to 1) provides the synchronization and this corresponds to the moment when the delay angle alpha equals zero. A gating with a delay of alpha degrees is generated and sent to the thyristors. The alpha value is updated instantaneously. Image:

Enable/Disable Sync. alpha Signal

Attributes: Parameters Frequency Pulse Width Description Operating frequency of the controlled switch/switch module, in Hz On-time pulse width of the switch gating, in deg.

The input for the delay angle alpha is in deg.

Switch Controllers

175

Example: The figure below shows a thyristor circuit using delay angle control. In the circuit, the zero-crossing of vs, which corresponds to the moment that the thyristor would start conducting naturally, is used to provide the synchronization. The delay angle is set at 30o. The gating signal is delayed from the rising edge of the synchronization signal by 30o.
vs iRL1

vsync

4.6.3 PWM Lookup Table Controller


There are four input signals in a PWM lookup table controller: the modulation index, the delay angle, the synchronization signal, and the gating enable/disable signal. The gating pattern is selected based on the modulation index. The synchronization signal provides the synchronization to the gating pattern. The gating pattern is updated when the synchronization signal changes from low to high. The delay angle defines the relative angle between the gating pattern and the synchronization signal. For example, if the delay angle is 10 deg., the gating pattern will be leading the synchronization signal by 10 deg. Image:

Enable/Disable Delay Mod. Sync. Angle Index Signal

176

Other Components

Attributes: Parameters Frequency Update Angle Description Switching frequency, in Hz Update angle, in deg., based on which the gatings are internally updated. If the angle is 360o, the gatings are updated at every cycle. If it is 60o, the gatings are updated at every 60o. Name of the file storing the PWM gating pattern

File Name

A lookup table, which is stored in a file, contains the gating patterns. It has the following format: n, m1, m2, ..., mn k1 G1,1, G1,2, ..., G1,k1 ... ... ... kn Gn,1, Gn,2, ..., Gn,kn where n is the number of gating patterns; mi is the modulation index correspondent to Pattern i; and ki is the number of switching points in Pattern i. The modulation index array m1 to mn should be monotonically increasing. The output will select the ith pattern if the input is smaller than or equal to mi. If the input exceeds mn, the last pattern will be selected. The following table shows an example of a PWM pattern file with five modulation index levels and 14 switching points. 5, 0.901, 0.910253, 0.920214, 1.199442, 1.21 14 7.736627 72.10303 80.79825 99.20176 107.8970 187.7366 252.1030 260.7982 279.2018 287.8970 14 7.821098 72.27710 80.72750 99.27251 107.7229 187.8211 252.2771 260.7275 279.2725 287.7229 14 7.902047 72.44823 80.66083 99.33917 107.5518

172.2634 180. 352.2634 360. 172.1789 180. 352.1789 360. 172.0979 180.

Switch Controllers

177

187.9021 252.4482 260.6608 279.3392 287.5518 352.0980 360. 14 10.186691 87.24225 88.75861 91.24139 92.75775 169.8133 180. 190.1867 267.2422 268.7586 271.2414 272.7578 349.8133 360. 14 10.189426 87.47009 88.97936 91.02065 92.52991 169.8106 180. 190.1894 267.4701 268.9793 271.0207 272.5299 349.8106 360. In this example, if the modulation index input is 0.8, the controller will select the first gating pattern. If the modulation index is 0.915, the controller will select the third pattern. Example: This example shows a three-phase voltage source inverter (file: vsi3pwm.sch). The PWM for the converter uses the selected harmonic elimination. The gating patterns are described above and are pre-stored in File vsi3pwm.tbl. The gating pattern is selected based on the modulation index. The waveforms of the line-to-line voltage and the threephase load currents are shown below.

178

Other Components

4.7

Function Blocks

4.7.1 Control-Power Interface Block


A control-power interface block passes a control circuit value to the power circuit. It is used as a buffer between the control and power circuit. The output of the interface block is treated as a constant voltage source when the power circuit is solved. With this block, some of the functions that can only be generated in the control circuit can be passed to the power circuit. Image:

Example: A Constant-Power Load Model In a constant-power dc load, the voltage V, current I, and power P have the relationship as P=V*I. Given the voltage and the power, the current can be calculated as I=P/V. This can be implemented using the circuit as shown below. The load voltage is measured through a voltage sensor and is fed to a divider. The output of the divider gives the current value I. Since the voltage could be zero or a low value at the initial stage, a limiter is used to limit the current amplitude. This value is converted into the load current quantity through a voltage-controlled current source.
LOAD I

k=1

Example: The following circuit illustrates how a control circuit signal can be passed to the power circuit. As seen from the power circuit, the CTOP block behaviors as a grounded voltage source.

Function Blocks

179

Control Circuit

Power Circuit

4.7.2 ABC-DQO Transformation Block


The ABC-DQO function blocks perform the abc-dqo transformation. They convert three voltage quantities from one coordinate to another. These blocks can be used in either the power circuit or the control circuit. Images:
ABC to DQO DQO to ABC

It should be noted that, in the power circuit, currents must first be converted into voltage quantities (using current-controlled voltage sources) before they can be transformed. Also, if an input terminal is not used (such as in the DQO-to-ABC transformation block where only Phase D and Q are not used, and Phase O is not used), it must be connected to ground. The transformation equations from abc to dqo are:
2 2 cos cos ----- cos + ----- 3 3

vd vq vo

va 2 2 2 v = -- sin sin ----- sin + ----b 3 3 3 vc 1 1 1 ---2 2 2

The transformation equations from dqo to abc are:

180

Other Components

cos va vb vc =

sin

vd 2 2 cos ----- sin ----- 1 vq 3 3 2 2 cos + ----- sin + ----- 1 3 3 vo

Example: In this example, three symmetrical ac waveforms are transformed into dqo quantities. The angle is defined as = t where = 2*60. Since the angle changes linearly with time, a piecewise linear voltage which has a ramp waveform is used to represent . The simulation waveforms show the three-phase ac (top), the angle (middle), and the dqo output. In this example, the q component is constant, and both the d and the o components are zero.

4.7.3 Math Function Blocks


The output of a math function block is expressed as the mathematical function of the inputs. With this block, one can implement complex and nonlinear relationship easily. Blocks with 1, 2, 3, 5, and 10 inputs are provided. Images:

Function Blocks

181

1-input

2-input

3-input

5-input

10-input

Attributes: Parameters Expression f(x1,x2,...,xn) Expression df/dxi Description Expression of the output versus inputs where n is the number of inputs Expression of the derivative of the function f versus the ith input

The derivative df/dxi can be set to zero. The variables that are allowed in the expression are: T or t for time, and xi (i from 1 to n) which represents the ith input. For example, for the 3-input math function block, the allowed variables are: T, t, x1, x2, and x3. For the 1-input math function block, the variable x, which refers to the only input, is also allowed.

4.7.4 Lookup Tables


There are three types of lookup tables: one-dimensional lookup table, 2-dimensional lookup table with integer inputs, and 2-dimensional lookup table with floating-point inputs. All three types of lookup tables can be used in both power circuit and control circuit. Images:
1-dimensional
Index i

2-dimensional
Index j

182

Other Components

Attribute: Parameter File Name Description Name of the file storing the lookup table

For the 2-dimensional lookup table block, the node at the left is for the row index input, and the node at the top is for the column index input. The one-dimensional lookup table has one input and one output. Two data arrays, corresponding to the input and the output, are stored in the lookup table in a file. The format of the table is as follows. Vin(1), Vo(1) Vin(2), Vo(2) ... Vin(n), Vo(n) The input array Vin must be monotonically increasing. Between two points, linear interpolation is used to obtain the output. When the value of the input is less than Vin(1) or greater than Vin(n), the output will be clamped to Vo(1) or Vo(n). The 2-dimensional lookup table with integer input has two inputs. The output data is stored in a 2-dimensional matrix. The two input correspond to the row and column indices of the matrix. For example, if the row index is 3 and the column index is 4, the output will be A(3,4) where A is the data matrix. The data for the lookup table are stored in a file and have the following format: m, n A(1,1), A(1,2), ..., A(1,n) A(2,1), A(2,2), ..., A(2,n) ... ... ... A(m,1), A(m,2), ..., A(m,n) where m and n are the number of rows and columns, respectively. Since the row or the column index must be an integer, the input value is automatically converted to an integer. If either the row or the column index is out of the range (for example, the row index is less than 1 or greater than m), the output will be zero. The 2-dimensional lookup table with floating-point inputs is similar to the 2dimensional lookup table with integer inputs. The difference is that in this case, inputs are floating-point values, and interpolation is used to calculate the output. The data for the lookup table are stored in a file and have the following format:

Function Blocks

183

m, n Vr,1 Vr,2 ... Vr,m Vc,1 Vc,2 ... Vc,n A(1,1), A(1,2), ..., A(1,n) A(2,1), A(2,2), ..., A(2,n) ... ... ... A(m,1), A(m,2), ..., A(m,n) where m is the number of rows and n is the number of columns; Vr is the row vector and Vc is the column vector; and A(i,j) is the output value at Row i and Column j. Note that Vectors Vr and Vc must be monotonically increasing. If the input falls between two points, interpolation is used to calculate the value. If the input is less than the minimum or greater than the maximum value, the input will be set to be the same as the minimum or maximum value. Examples: The following shows a one-dimensional lookup table: 1., 10. 2., 30. 3., 20. 4., 60. 5., 50. If the input is 0.99, the output will be 10. If the input is 1.5, the output will be
( 1.5 1 ) ( 30 10 ) 10 + ----------------------------------------------- =20. 21

The following shows a 2-dimensional lookup table with integer inputs: 3, 4 1., -2., 4., 1. 2., 3., 5., 8. 3., 8., -2., 9. If the row index is 2 and the column index is 4, the output will be 8. If the row index is 5, regardless of the column index, the output will be 0. The following shows a 2-dimensional lookup table with floating-point inputs: 3, 4 1.1 2.2 3.3

184

Other Components

1.2 2.3 3.4 4.5 1., -2., 4., 1. 2., 3., 5., 8. 3., 8., -2., 9. If the row input is 2 and the column input is 3, the following table shows the four points that enclose the input point, and the output value of 3.826 through interpolation: Column 2.3 1.1 Row 2 2.2 -2 2.091 3 3.826 3 3.4 4 4.818 5

4.7.5 C Script Block


The C script block allows users to enter C code directly without compiling the code, unlike in the case of external DLL blocks where users need to compile the code into a DLL using a compiler. The code of the C script block will be interpreted and executed at runtime by a built-in C interpreter in PSIM. This block makes it very easy to support custom C codes, and to define and modify the functionality of the block. The interface of the C script block dialog window is shown below. In the Number of Input/Output Ports section, the number of input and output ports of the ports is defined. After the number of ports is changed, the image of the block in the schematic will change accordingly. In the Function Type section, there are four choices: Variable/Function Definitions: For includes statements and global variable definition. OpenSimUser Fcn: The function that is called only once at the beginning of the simulation for initialization. RunSimUser Fcn: The function that is called at each simulation step. CloseSimUser Fcn: The function that is called only once at the end of the simulation for termination. When one of the choices is selected, the area underneath shows the corresponding code. The complete code consists the combined code of all the four parts.

Function Blocks

185

Input/output ports

Function selection

Area for custom code

Click on the Check Code button to check if the code has any compiling errors. Click on the Edit Image button to customize the image of the C script block. The difference between the C script block and the external DLL block is that, even though the C script block is easier to use, it does have the disadvantage that the custom code in the C script block can not be debugged, while in the external DLL block it is possible to set break points and trace/step through the code for debugging.

4.7.6 External DLL Blocks


An external DLL (dynamic link library) block allows users to write code in C/C++, compile it into DLL using Microsoft Visual C/C++, and link it with PSIM. These blocks can be used in either the power circuit or the control circuit. A DLL block receives values from PSIM as inputs, performs the calculation, and sends the results back to PSIM. PSIM calls the DLL routine at each simulation time step. However, when the inputs of the DLL block are connected to one of these discrete elements (zero-order hold, unit delay, discrete integrators and differentiators, z-domain

186

Other Components

transfer function blocks, and digital filters), the DLL block is called only at the discrete sampling times. Two types of DLL blocks are provided: Simple DLL Block and General DLL Block. The simple DLL block has a fixed number of inputs and outputs, and the DLL file name is the only parameter that needs to be defined. On the other hand, the general DLL block allows users to define arbitrary number of inputs/outputs and additional parameters. Users can also customize the DLL block image. In general, the simple DLL block is easier to program and easier to use. The images and parameters of the simple DLL blocks are shown below. Images:
1-input 1 2 3 input 3-input 1 2 3 output 6 6 1 6-input 1

Attribute: Parameter File Name Description Name of the DLL file

The node with a dot is for the first input (in[0]). The sequence of the input/output nodes is from the top to the bottom. The images and parameters of the simple DLL blocks are shown below. Image (for a block with 2 inputs and 3 outputs):
1 2 input 1 2 3 output

Function Blocks

187

Attribute: Parameter DLL File Input Data File Number of Input Nodes Number of Output Nodes IN Nodes OUT Nodes Parameter 1 Parameter 2 Edit Image (button) Display File (button) Read File (button) Description Name of the DLL file Name of the input data file that the DLL routine reads (optional) Number of input nodes (optional) Number of output nodes (optional) List of input nodes (optional) List of output nodes (optional) Parameter to be passed from PSIM into the DLL routine (optional) Parameter to be passed from PSIM into the DLL routine (optional) Click this button to edit and customize the image of the DLL block. Click this button to display the content of the Input Data File (optional). If the Input Data File is modified, click this button to reload the data file (optional).

The node with a dot is for the first input (in[0]). The sequence of the input/output nodes is from the top to the bottom. By default, users define the number of inputs and outputs. But the number of inputs and outputs, the node names, as well as the number of parameters and the parameter names can all be defined inside the DLL routine. For more details on defining and programming for the general DLL block, please refer to the help file "Help General DLL Block.pdf" and related examples. The name of the DLL file can be arbitrary. The DLL file can be placed in one of the three places, in the order of precedence: in the PSIM directory, in the same directory as the schematic file that uses the DLL file, or in the directory as defined in the Options -> Set Path function in PSIM. Sample DLL files are provided in PSIM, and users can use these files as the templates to

188

Other Components

write their own. Procedures on how to compile the DLL routine and link with PSIM are provided in these files and in the on-line help. Example: The following shows a power factor correction circuit with the inductor current and the load voltage feedback. The input voltage is used to generate the current reference. The control scheme is implemented in a digital environment, with a sampling rate of 30 kHz. The control scheme is implemented in an external C code and is interfaced to the power circuit through a simple DLL block. The input of the DLL block are the sampled input voltage, inductor current, and output voltage. One of the DLL block outputs is the modulation wave Vm, which is compared with the carrier wave to generate the PWM gating signal for the switch. The other output is the inductor current reference for monitoring purpose.

Part of the source code, which is in the file pfc_vi_dll.c, is shown below. Both the inner current loop and the outer voltage loop use a PI controller. Trapezoidal rule is used to discretize the controllers. Discretization using Backward Euler is also implemented but the codes are commented out.

Function Blocks

189

// This sample program implement the control of the circuit "pfc-vi-dll.sch" in a C routine. // Input: in[0]=Vin; in[1]=iL; in[2]=Vo // Output: Vm=out[0]; iref=out[1] // You may change the variable names (say from "t" to "Time"). // But DO NOT change the function name, number of variables, variable type, and sequence. // Variables: // t: Time, passed from PSIM by value // delt: Time step, passed from PSIM by value // in: input array, passed from PSIM by reference // out: output array, sent back to PSIM (Note: the values of out[*] can be modified in PSIM) // The maximum length of the input and output array "in" and "out" is 20. // Warning: Global variables above the function simuser (t,delt,in,out) are not allowed!!! #include <math.h> __declspec(dllexport) void simuser (t, delt, in, out) // Note that all the variables must be defined as "double" double t, delt; double *in, *out; { // Place your code here............begin double Voref=10.5, Va, iref, iL, Vo, Vm, errv, erri, Ts=33.33e-6; static double yv=0., yi=0., uv=0., ui=0.; // Input Va=fabs(in[0]); iL=in[1]; Vo=in[2]; // Outer Loop errv=Voref-Vo; // Trapezoidal Rule yv=yv+(33.33*errv+uv)*Ts/2.; iref=(errv+yv)*Va; // Inner Loop erri=iref-iL; // Trapezoidal Rule yi=yi+(4761.9*erri+ui)*Ts/2.; Vm=yi+0.4*erri; // Store old values uv=33.33*errv; ui=4761.9*erri; // Output out[0]=Vm; out[1]=iref; // Place your code here............end }

190

Other Components

4.7.7 Embedded Software Block


The Embedded Software Block is a special type of the external DLL blocks. It is intended for modeling embedded software devices such as microcontrollers and DSP. Attribute: Parameter DLL File Number of Nodes Description Name of the DLL file that defines the functionality and the interface of the block Total number of input and output nodes

The Embedded Software Block has similar functionality as the general external DLL block. However, unlike the general DLL block whose connection nodes are predefined as either inputs or outputs, the Embedded Software Block allows the node types to be programmed as needed. Also, additional information, such as the exact instant at which the state of a variable changes, can be calculated and passed to and from PSIM. The Embedded Software Block is a control circuit element, and can be used in the control circuit only. For more information on how to use the Embedded Software Block, please refer to the document "Help Embedded Software Block.pdf".

Function Blocks

191

192

Other Components

5
Analysis Specification
5.1 Transient Analysis
The transient analysis is set up by selecting Simulation Control in the Simulate menu in PSIM, and defining the parameters as follows. Time Step Total Time Free Run checkbox Simulation time step, in sec. Total simulation time, in sec. When the Free Run checkbox is not checked, the simulation will run up to the Total Time and then stop. But when it is checked, the simulation will run in the free-run mode and it will keep on running until manually stopped. In the free-run mode, voltage/current scopes can be used to monitor and display voltages and currents in the middle of the simulation. Print Time Print Step Time from which simulation results are saved to the output file. No output is saved before this time. Print step. If the print step is set to 1, every data point will be saved to the output file. If it is 10, for example, only one out of 10 data points will be saved. This helps to reduce the output file size. Flag for the LOAD function. If the flag is 1, the previous simulation values will be loaded from a file (with the .ssf extension) as the initial conditions. Flag for the SAVE function. If the flag is 1, values at the end of the current simulation will be saved to a file with the .ssf extension.

Load Flag

Save Flag

With the SAVE and LOAD functions, the circuit voltages, currents and other quantities can be saved at the end of a simulation session, and loaded back as the initial conditions for the next simulation session. This provides the flexibility of running a long simulation in several shorter stages with different time steps and parameters. Components values and parameters of the circuit can be changed from one simulation session to the other. The circuit topology, however, must remain the same.

Transient Analysis

193

In PSIM, the simulation time step is fixed throughout the simulation. In order to ensure accurate simulation results, the time step must be chosen properly. The factors that limit the time step in a circuit include the switching period, widths of pulses or waveforms, and intervals of transients. It is recommended that the time step should be at least one magnitude smaller than the smallest of the above. In PSIM, an interpolation technique is implemented which will calculate the exact switching instants. With this technique, the error due to the misalignment of switching instants and discrete simulation points is significantly reduced. It is possible to simulate with a large time step while still maintaining accurate results. The allowable maximum time step is automatically calculated in PSIM. It is compared with the time step set by the user, and the smaller value of the two will be used in the simulation. If the selected time step is different from the one set by the user, it will be saved to the file message.txt.

5.2

AC Analysis
The frequency response of a circuit or a control loop can be obtained with the ac analysis. A key feature of the ac analysis in PSIM is that, a circuit can be in its original switchmode form, and no average model is required. Nevertheless, with the average model, the time it takes to perform the ac analysis will be shorter. The following are the steps to set up the ac analysis: - Identify a sinusoidal voltage source as the excitation source for the ac sweep. - Place ac sweep probes at the desired output location. To measure the loop response of a closed control loop, use the node-to-node probe. - Place the .ACSWEEP element on the schematic, and define the parameters of the ac sweep. - Run the simulation. Below are the images of the ac sweep probes and the .ACSWEEP sweep element. Images:
AC Sweep Probe AC Sweep Probe (loop) .ACSWEEP

194

Analysis Specification

Attributes: Parameters Start Frequency End Frequency No. of Points Flag for Points Description Start frequency of the ac sweep, in Hz End frequency of the ac sweep, in Hz Number of data points Flag to define how the data points is generated. Flag = 0: Points are distributed linearly in LOG10 scale Flag = 1: Points are distributed linearly in linear scale Source Name Start Amplitude End Amplitude Freq. for extra Points Name of the excitation source Excitation source amplitude at the start frequency Excitation source amplitude at the end frequency Frequencies of additional data points. If the frequencydomain characteristics change rapidly at a certain frequency range, one can add extra points in this region to obtain better data resolution.

The principle of the ac analysis is that a small ac excitation signal is injected into the system as the perturbation, and the signal at the same frequency is extracted at the output. To obtain accurate ac analysis results, the excitation source amplitude must be set properly. The amplitude must be small enough so that the perturbation stays in the linear region. On the other hand, the excitation source amplitude must be large enough so that the output signal is not affected by numerical errors. In general, a physical system has low attenuation in the low frequency range and high attenuation in the high frequency range. A good selection of the excitation source amplitude would be to have a relatively small amplitude at the low frequency, and a relatively large amplitude at the high frequency. Sometimes, after ac analysis is complete, a warning message is displayed as follows:
Warning: The program did not reach the steady state after 60 cycles. See File message.txt for more details.

This message occurs when the software fails to detect the steady state at the ac sweep output after 60 cycles. To address this problem, one may increase damping in the circuit (by including parasitic resistances, for example), or adjust the excitation source amplitude, or reduce simulation time step. The file message.txt gives the information on the frequency at which this occurs and the relative error. The relative error will indicate how far the data point is from reaching the steady state.

AC Analysis

195

Example: Impedance of Shunt Filters The circuit below consists of two shunt filters tuned at the 5th and 7th harmonics (the fundamental frequency is 60 Hz). By injecting the excitation source as the current and measuring the voltage, we obtain the impedance characteristics of the filters. The ac analysis waveform on the right clearly shows two troughs at 300 Hz and 420 Hz.

Example: Open-Loop Response of a Buck Converter The circuit on the left is an one-quadrant buck converter. An excitation source is injected to the modulation signal, and the output voltage is measured. The result of the ac analysis, on the right, shows the open-loop response of the output voltage versus the modulation signal.

196

Analysis Specification

Example: Loop Transfer Function of a Closed-Loop Circuit The ac analysis can be used to find out the loop response of a closed-loop system. The circuit below shows a buck converter with average current mode control. By injecting the excitation signal into the current feedback path, and using the node-to-node ac sweep probe, we can obtain the loop transfer function directly. With the loop transfer function, one can determine the bandwidth of the control loop and the phase margin. Please note that the ac sweep probe should be connected such that the dotted side is connected to the node after the excitation source injection.

Example: Loop Transfer Function of a Switchmode Power Supply The loop transfer function of a switchmode power supply controlled by a PWM IC can also be determined in a similar way. The figure below shows a buck converter controlled by TI UC3842. The excitation source can be inserted in the feedback path, before the op. amp. output.

AC Analysis

197

5.3

Parameter Sweep
Parameter sweep can be performed for the following parameters: - Resistance, inductance, and capacitance of RLC branches - Gain of proportional blocks - Time constant of integrators - Gain and time constant of proportional-integral controllers - Gain, cut-off frequency, and damping ratio of 2nd-order low-pass and highpass filters - Gain, center frequency, and passing and stopping band of 2nd-order band-pass and band-stop filters The image and parameters of the parameter sweep element are shown below.

198

Analysis Specification

Image:

Attributes: Parameters Start Value End Value Increment Step Parameter to be Swept Description Starting value of the parameter End value of the parameter Increment step Parameter to be swept

For example, let the resistance of a resistor be Ro. To sweep the resistance from 2 Ohm to 10 Ohm, with a step of 2 Ohm, the specification will be: Start Value End Value Increment Step Parameter to be Swept 2 10 2 Ro

Parameter Sweep

199

200

Analysis Specification

6
Circuit Schematic Design
PSIMs schematic program provides interactive and user-friendly interface for circuit schematic entry and editing. The following figure shows a boost power factor correction circuit in the PSIM environment.

In PSIM, all the elements are stored under the Elements menu. The elements are divided into four groups: Power (for power circuit element), Control (for control elements), Other (for switch controllers, sensors, probes, interface elements, and elements that are common to both power and control), and Sources (for voltage and current sources).

Parameter Sweep

201

6.1

Creating a Circuit
The following functions are provided for circuit creation. Get There are two ways to get an element from the element library. One is to use the pull-down menu. Go to the Elements menu, and go into the submenu and highlight the element to be selected. Another is to use the Library Browser, as shown below.

The Library Browser provides a convenient way of navigating through the library. To display the Library Browser, go to View -> Library Browser. Also, the most recent elements are listed in the pull-down button on the toolbar. Place Once an element is selected from the menu, the image of the element will appear on the screen and move with the mouse. Click the left button of the mouse to place the element. Before the element is placed, right click to rotate the element. After an element is selected, select Rotate to rotate the element.

Rotate

202

Circuit Schematic Design

Wire

To connect a wire between two nodes, select Wire. The image of a pen will appear on the screen. To draw a wire, keep the left button of the mouse pressed and drag the mouse. A wire always starts from and end at a grid intersection. For easy inspection, a floating node is displayed as a circle, and a junction node is displayed as a solid dot.

Label

If two or more nodes are connected to the same label, they are connected. It is equivalent as though they were connected by wire. Using labels will reduce the cross-wiring and improve the schematic layout. The text of a label can be moved. To select the text, left click on the label, then press the Tab key.

Assign

To assign the parameters of an element, double click on the element. A dialog box will appear. Specify the values and hit the <Return> key or click on OK.

6.2

Editing a Circuit
Double left click or single right click on top of an element will bring up the property dialog window. Also, to move the whole schematic, right click and drag the mouse. The following functions are provided in the Edit menu for circuit editing: Select To select an element, click on the element. A rectangle will appear around the element. To select a block of a circuit, keep the left button of a mouse pressed and drag the mouse until the rectangle covers the selected area. Copy To copy an element or a block of the circuit, select the element or the region, and choose Copy. Then choose Paste place the element or circuit. To delete an element, a block of a circuit, or a wire, select the item, and choose Cut, or hit the <Delete> key. Note that if Cut is used, the last deleted item can be pasted back. This is equivalent to un-do. To move an element or a circuit block, select the element/circuit block and drag the mouse while keeping the left button pressed. To place text on the screen, choose Text. Enter the text in the

Delete

Move Text

Editing a Circuit

203

dialog box, and click the left button of the mouse to place it. Disable To disable an element or part of a circuit. When the element or the circuit is disabled, it will be grayed out and will be treated as nonexistent as far as the simulation is concerned. This function is useful if an element or circuit needs to be excluded but not deleted from the circuit. To enable a previously disabled element or circuit. Quit from any of the above editing modes by choosing Escape.

Enable Escape

Copy to Clipboard To copy the schematic image to the clipboard which can then be pasted back in another software. One can choose either the Color option or the Black & White option. The Black & White option will result in a smaller image file size. Drawing To draw images on the schematic for display purposes. The following images are provided: line, ellipse, rectangle, and halfcircle. To add or remove the current scope for elements that have current flags. After this is selected, a scope image will appear with the mouse. Then click on top of an element with the current flag, and select the branch current name. Select the branch current again to remove the current scope.

Add/Remove Current Scope

Show/Hide To show or hide the parameters of elements that can be changed Runtime Variables at runtime in the middle of the simulation. After this is selected, the text of the parameter will appear. Click on the text, and a small dialog window will appear. Enter the new

value directly in the data field, and click Apply. Or alternatively, click on the up/down arrow keys on the keyboard to increase/ decrease the value. In addition, the following functions are provided in the View menu: Zoom Select Zoom In to zoom in the circuit, or Zoom In Selected to zoom in to a selected region. Choose Zoom Out to zoom out, or Fit to Page to zoom out to fit the entire circuit to the screen. To generate the parts list of the circuit. To count the number of elements. Voltage/current probes and meters are not included in the element count.

Element List Element Count

204

Circuit Schematic Design

Custom Toolbars

To create customized toolbars.

Custom Keyboard To customize keyboard. Functions can be assigned to the keyboard for easier circuit editing. The procedures for create customized toolbars and to customize keyboards are described below. Customizing Toolbars: To create a toolbar called "new" and add the AND gate to the toolbar, for example, do the following: - Choose View -> Custom Toolbars. The Custom Toolbars dialog window will appear. Choose New Toolbar, and the following window will appear.

Toolbar icon area Predefined icon images

Icon
editing area

- Specify the Toolbar Name as "new". - Draw the AND gate icon in the icon editing area. Or if the icon is already available in the predefined icon images, select the icon and copy it to the icon editing area. - Under the Edit Command section, with the option Elements selected, highlight "AND Gate". Then click on the Add Button. The icon will appear in the toolbar icon area. Click on OK to close the window, and go back to the

Editing a Circuit

205

Custom Toolbars window. - Check "new" in the Custom Toolbars dialog window, and the new toolbar will appear. Uncheck the box will hide the toolbar. Customizing Keyboard: To define the key "r" for getting a resistor from the library, for example, do the following: - Choose View -> Custom Keyboard. The Custom Toolbars dialog window will appear. Choose New Toolbar, and the following window will appear.

- In the section Add Shortcut Key, select the option Elements. Then find and highlight the element "Resistor". - Move the cursor into the input field of Press new shortcut key, and press the key "r" on the keyboard. Then click on Assign. - The key "r" will be assigned to the resistor, and the definition will appear in the Current Shortcut Key list.

6.3

Saving a File
After a schematic is created, it can be saved to a binary file by choosing the Save or Save As function in the File menu. By choosing File -> Save with Password, one can protect a file with a password. When a file is password protected, it can still be used in the simulation, but one needs to enter the correct password in order to see the schematic. The password protection is used in

206

Circuit Schematic Design

situations where the person who created the file needs to share it with someone else, but does not wish to reveal the details of the schematic. The function Save in Package File in the File menu allows users to save all the files that are associated with a simulation to one single file. This is especially useful if the main circuit calls multiple subcircuits, and one needs to send the files to someone else. Rather than finding and collecting all the subcircuit files, one can just create the package file and send the single file out. The function Save as Version 6.2 in the File menu saves a file in the Version 6.2 format. Note that if the file uses elements that are unique in Version 7.0, these elements will be omitted. Also, Version 6.2 file format is very close to Version 6.1 format, and a file in Version 6.2 format can be opened by PSIM Version 6.1.

6.4

Subcircuit
The following functions are provided for subcircuit editing and manipulation. New Subcircuit Load Subcircuit Edit Subcircuit Set Size Place Port Display Port Edit Default Variable List Edit Image To create a new subcircuit To load an existing subcircuit. The subcircuit will appear on the screen as a block. To edit the size and file name of the subcircuit To set the size of the subcircuit To place the connection port between the main circuit and the subcircuit To display the connection port of the subcircuit To edit the default variable list of the subcircuit To edit the subcircuit image

Display Subcircuit To display the subcircuit name Name Show Subcircuit Ports Hide Subcircuit Ports Subcircuit List One Page up To display the port names of the subcircuit in the main circuit To hide the port names of the subcircuit in the main circuit To list the file names of the main circuit and the subcircuits To go back to the main circuit. The subcircuit is automatically

Subcircuit

207

saved. Top Page To jump from a lower-level subcircuit to the top-level main circuit. This is useful for circuits with multiple layers of subcircuits.

The one-quadrant chopper circuit below illustrates the use of the subcircuit.
Subcircuit Inside the subcircuit:

File: chop.sch

File: chop_sub.sch

6.4.1 Creating Subcircuit - In the Main Circuit


The following are the steps to create the subcircuit chop_sub.sch in the main circuit chop.sch. - Open or create the main circuit chop.sch. - If the file chop_sub.sch does not exist, go to the Subcircuit menu, and select New Subcircuit. If the file exists, select Load Subcircuit instead. - A subcircuit block (rectangle) will appear on the screen. Place the subcircuit.

6.4.2 Creating Subcircuit - Inside the Subcircuit


To enter the subcircuit, double click on the subcircuit block. - Create/edit the content of the subcircuit circuit exactly the same way as in the main circuit. - To specify the subcircuit size, select Set Size in the Subcircuit menu. In this example, the size is set to 4x7 (width of 4 divisions and height of 7 divisions). Note that the size of the subcircuit should be chosen such that it gives the proper appearance and allows easy wire connection in the main circuit. - Once the subcircuit is complete, define ports to connect the subcircuit nodes with the corresponding nodes in the main circuit. Choosing Place Port in the Subcircuit menu, and a port image will appear. After the port is placed in the

208

Circuit Schematic Design

circuit, a pop-up window (shown on the left below) will appear.

Subcircuit port assignments

The diamonds on the four sides represent the connection nodes and the positions of the subcircuit. They correspond to the connection nodes of the subcircuit block on the right. There are no diamonds at the four corners since connections to the corners are not permitted. When a diamond is selected, it is colored red. By default, the left diamond at the top is selected and marked with red color. Click on the desired diamond to select and to specify the port name. In this example, in the main circuit chop.sch, there are four linking nodes, two on the left side and two on the right side of the subcircuit block. The relative position of the nodes are that the upper two nodes are 1 division below the top and the lower two nodes are 1 division above the bottom. To specify the upper left linking node, click on the top diamond of the left side, and type in+. The text in+ will be within that diamond box and a port labelled with in+ will appear on the screen. Connect the port to the upper left node. The same procedure is repeated for the linking nodes in-, out+, and out-. - After the four nodes are placed, the node assignment and the subcircuit appear in PSIM as shown below.

Subcircuit

209

The creation of the subcircuit is now complete. Save the subcircuit, and go back to the main circuit.

6.4.3 Connecting Subcircuit - In the Main Circuit


Once the subcircuit is created and connection ports are defined, complete the connection to the subcircuit block in the main circuit. - In the main circuit, the connection points on the borders of the subcircuit block appear as hollow circles. - Select the subcircuit block, and select Show Subcircuit Ports in the Subcircuit menu to display the port names as defined inside the subcircuit. - Connect the wires to the connection points accordingly.

6.4.4 Other Features of the Subcircuit


This section describes other features of the subcircuit through the example shown below.

210

Circuit Schematic Design

File: main.sch
Inside the subcircuit:

File: sub.sch

6.4.4.1 Passing Variables from the Main Circuit to Subcircuit


In this example, the main circuit main.sch uses a subcircuit sub.sch. In the subcircuit, the inductance value is defined as L and the capacitance is defined as C. The default values of L and C can be set by selecting Subcircuit | Set Default Variable List. In this case, L is set to 5mH and C is set to 100uF. When the subcircuit is loaded into the main circuit the first time, this default variable list will appear in the tab Subcircuit Variables in Subcircuit | Edit Subcircuit from the main circuit main.sch. New variables can be added here and variable values can be changed. In this case, L is changed to 2mH, and C is kept the same as the default value. Note that the variables and the values are saved to the netlist file and used in simulation. The default variable list inside the subcircuit is not saved to the netlist and is not used for simulation. This feature allows the parameters of a subcircuit to be defined at the main circuit level.

Subcircuit

211

In the case where the same subcircuit is used several times in one main circuit, different parameters can be assigned to the same variable. For example, if the subcircuit sub.sch is used two times in above example, in one subcircuit L can be defined as 3mH, and in another subcircuit L can be defined as 1mH. Note that this example also illustrates the feature that parameters can be defined as a variable (for example Vin for the input dc voltage source) or a mathematical expression (for example R1+R2 for the load resistance). The variables Vin, R1, and R2, are defined in the parameter file para-main.txt. See Section 4.1 for more details.

6.4.4.2 Customizing the Subcircuit Image


The following are the procedures to customize the subcircuit image of sub.sch: - In the subcircuit, select Edit Image in the Subcircuit menu. A window will pop-up, as shown below.

In the window, the diamonds marked red are the connection nodes of the subcircuit block, in exactly the same positions as appearing in the main circuit. - Use the drawing tool to create/edit the image for the subcircuit block. If the drawing tool is not already displayed, go to the View menu and check Drawing Tools. Click on Zoom In and Zoom Out icons on the toolbar to adjust the size of the image working area. After the image is created, the pop-out window will appear as follows.

212

Circuit Schematic Design

- Go back to the subcircuit window (sub.sch in this case), and save the subcircuit. The new subcircuit block image should appear in the main circuit.

6.4.4.3 Including Subcircuits in the PSIM Element List


If you create a directory called User Defined under the PSIM directory, and place subcircuits inside this directory. subcircuits will appear as items in the Elements menu, under Elements | User Defined, just like any other PSIM elements. You can also create subdirectories under the directory User Defined, and place subcircuits inside the subdirectories. For example, the Elements menu may look like this: - Power - Control - Other - Sources - Symbols - User Defined - Subcircuit 1 - Project A
- Subcircuit 2

Subcircuit

213

- Subcircuit 3

- Project B
- Subcircuit 4

In this way, common-used custom-built subcircuits can be grouped together and easily managed and accessed.

6.5

Running the Simulation


To run the simulation, choose Run PSIM from the Simulate menu. This will start the PSIM simulation. To view the simulation results, choose Run SIMVIEW from the Simulate menu. To view the simulation results in the middle of the simulation, one can either go to Simulate -> Runtime Graphs to select the waveforms, or use the voltage/current scopes (under Elements -> Other -> Probes) to view the waveforms. The difference between the runtime graphs and the voltage/current scopes is that only waveforms that are saved for display in SIMVIEW (such as voltage probes, current probes, current flags, etc.) are available for the runtime graphs. In addition, a runtime graph display the waveform in its entirety, from the beginning to the final study time. Because of this, the runtime graphs are disabled in the free-run mode as the final study time is undetermined. On the other hand, voltage/current scopes can be used in either the one-time simulation mode or in the free-run mode. Voltage scopes can be connected to any nodes, and will display the node-to-ground voltage waveforms. On the other hand, current scopes are available to elements that have current flags (such as R-L-C branches and switches). Moreover, in the free-run mode, the majority of the element parameters can be changed during runtime in the middle of the simulation. This makes it possible to tune a circuit while inspecting key waveforms using voltage/current scopes, until desired performance is achieved. Running Simulation in the Free-Run Mode: To illustrate how to run a simulation in the free-run mode, a buck converter circuit shown below is used as an example. The circuit on the left was originally set up for the one-time simulation, with the total simulation time set to a specific value.

214

Circuit Schematic Design

One-time simulation

Simulation in the free-run mode

To set up the simulation in the free-run mode: - In Simulation Control, check the Free Run checkbox. - Go to Elements -> Other -> Scopes, and select the 2-channel voltage scope. Connect the scope as shown above on the right. - Double click on the scope, and the scope image will appear. Start the simulation, and the waveforms will appear and will be updated continuously in the scope. Change the scope settings as desired. - Elements parameters can now be adjusted in the middle of the simulation. To adjust the gain of the PI controller, for example, right click on top of the PI block, and choose Runtime Variables -> Gain. The text of the gain "0.6" will be displayed if it has not been displayed already. - Click on the text "0.6", and a small dialog window will appear. The screen should look as follows.

Running the Simulation

215

Gain of the PI controller

- Place the cursor inside the input field of the dialog window for the gain, and change the gain either by pressing on the upper/down arrow keys on the keyboard, or by entering a new value and then clicking on Apply. Watch how the waveforms change as the gain is changed. Other parameters, such as current reference, dc input voltage, inductance, capacitance, and load resistance, can be changed in the similar way. - Branch currents can also be displayed in the free-run mode. To display the inductor current, for example, right click on top of the inductor, and a menu will appear. Choose Current Scopes and the branch current name. - An image of the current scope (similar to the voltage scope image, but without connection terminals) will appear. Double click on the scope to expand and view the inductor waveform. Below is how the window would look like with both the voltage scope and the current scope. Other branch currents, such as capacitor current, load current, diode current, or MOSFET switch current, can be displayed in the similar way.

216

Circuit Schematic Design

Current scope

Voltage scope

Running Simulation with the Command-Line Option: Simulation can also be launched with the command line option by running the program PsimCmd.exe. For example, to simulate the circuit "chop.sch" which is stored in the folder "c:\psim\examples", go to the PSIM folder, and run the following command: PsimCmd -i "c:\psim\examples\chop.sch" -o "c:\psim\examples\chop.smv" The format of the command line is as follows: PsimCmd -i "[input file]" -o "[output file]" -v "VarName1=VarValue1" -v "VarName2=VarValue2" -t "TotalTime" -s "TimeStep" -g Note that the quotes around the parameter values must be present. The command-line parameters are: -i: -o: -v: Input schematic file name Output file name (in either .txt or .smv extension) Variable name and value. This parameter can be used multiple times. For example, to define the resistance R1 as 1.5 and the inductance L1 as 0.001, we have: -v "R1=1.5" -v "L1=0.001"

Running the Simulation

217

-t: -s: -g

Total time of the simulation Time step of the simulation Run SIMVIEW after the simulation is complete

With the command-line option, one can run several circuits automatically in a batch run.

6.6

Managing the PSIM Library


The PSIM library consists of two parts: one is the image library (psimimage.lib) and the other is the netlist library (psim.lib). The netlist library can not be modified. But users can modify the image library, or create their own image library. To create or modify the image library, go to Edit -> Edit Library -> Edit Library Files, and follow the instructions on the screen. Any image libraries in the PSIM directory will be automatically loaded into PSIM. There are two ways to add a custom model to the PSIM library list. One is to have the model in the form of a subcircuit, and then place the schematic file in a folder called user defined in the PSIM directory, or in one of the sub-folders of the user defined folder. Any schematic files and sub-folders under the user defined folder will appear in the PSIM library list. Another way is to add the custom model directly to an image library. The advantage of this approach is that the custom element will have the same look-and-feel as the standard PSIM elements, giving it a better interface. It is also possible to associate a help file to the custom model. Below are the procedures to add the custom models to the PSIM library.

6.6.1 Adding a New Subcircuit Element into the Library


There are three main steps to add a new element, modeled in a subcircuit, into the PSIM library: - Create the subcircuit model of the new element. - Add this element to the PSIM library. - Create an on-line help file for this new element. To illustrate this process, a LC-filter element is used as an example. Creating the Subcircuit: The first step is to create the subcircuit of the new element in the same way as if the subcircuit is to be called by another circuit. For example, the subcircuit of the 2nd-order LC filter, called "LC_filter.sch", and its image are shown below:

218

Circuit Schematic Design

In this case, the inductance and capacitance values will be defined through the interface, and need to appear in the property window of the new LC filter element. Therefore, the parameter value for the inductance needs to be defined as a variable, in this case, L, and the value for the capacitance as C. Then from Subcircuit -> Edit Default Variable List, add the variables L and C as the default variables. This step is necessary as the new element obtains the parameter information from the default variable list. The default variable list window should appears as follows.

Here Variable Label is the text that describes the parameter, Variable Name is the variable that is used as the parameter value in the subcircuit, and Variable Value is the

Managing the PSIM Library

219

default value of the parameter. For example, for the inductance L, the Variable Label is Inductance, the Variable Name is L, and the Variable Value is 1m. Adding the New Element to the PSIM Library: To add the subcircuit element into the PSIM library, follow these steps: - Go to Edit -> Edit Library -> Edit Library Files, and choose the library for the new element. Click on New Library to create a new image library, or select an existing library and click on Edit Selected Library. - In the Library Editor, click on the button New Subcircuit. Enter the information to the dialog window as shown below:

The explanation of each field is as follows: Name: Name of the new element as it appears in the PSIM library Description: Description of the new element File Path: The location of the subcircuit schematic file "LC_filter.sch". The subcircuit file must be placed in the \lib sub-folder in the PSIM directory. Hide (menu): Leave this box unchecked. If this box is checked, this element will not appear in the library. Help File: On-line help file associated with this element. Help ID: The ID used in the help map file to link the designated help page. - Click on the buttons Save Image Library and Update Menu. The new element will appear in the library and will be ready to use.

220

Circuit Schematic Design

Creating the On-Line Help File for the New Element: An on-line help file can be created for this new element, so that when the Help button is clicked in the property dialog window, the corresponding help page will come up. The following is the procedure to create the help file using Microsoft Help Workshop. - Prepare the help content in the .rtf file "LC_Filter.rtf" using Microsoft Word. Note that the footnote of the file should look as follows:
#LC_FILTER $LC_FILTER kLC_FILTER;

LC filter

Here the # label is used to link the help page with the LC filter element in PSIM. The k label will appear in the Index in the Help file, and the $ label is not used. - Prepare the help map file "HelpMap.txt". It is a text file, and has the following content: LC_FILTER=1001 Here the text "LC_FILTER" must be the same as the # label in the "LC_Filter.rtf" file, and the number "1001" must be the same as the Help ID defined for the LC filter element when it was created. - In the Help Workshop project file "LC_Filter.hpj", have the following settings: - Click on the Files button, and add the file "LC_Filter.rtf". - Click on the Options button, and in the Files tab, set Help File as LC_Filter.hlp. - Click on the Map button, and then click on Include to include the map file HelpMap.txt. - Click on Save and Compile to create the help file "LC_Filter.hlp". Place this file in the PSIM directory.

6.6.2 Adding a New DLL Element into the Library


Similar to that of a subcircuit element, there are three main steps to add a new element, modeled in a DLL, into the PSIM library: - Create the model in the DLL file. - Add this element to the PSIM library. - Create an on-line help file for this new element.

Managing the PSIM Library

221

To illustrate this process, an inductor is used as an example. Creating the DLL: The first step is to create the inductance model in DLL. Please refer to the relevant section on how to create a custom DLL. Here we assume that the DLL file, "inductor_model.dll", has already been created using the Power Modeling Block. It has one parameter called "Inductance", and two connecting nodes. Adding the New Element to the PSIM Library: To add the DLL element into the PSIM library, follow these steps: - Go to Edit -> Edit Library -> Edit Library Files, and choose the library for the new element. Click on New Library to create a new image library, or select an existing library and click on Edit Selected Library. - In the Library Editor, click on the button New DLL File. Enter the information to the dialog window as shown below:

The explanation of each field is as follows: Name: Name of the new inductor element as it appears in the PSIM library Description: Description of the new inductor element File Path: The location of the DLL file "inductor_model.dll" that models the new inductor element. The DLL file must be placed in the lib sub-folder in the PSIM directory. Input Nodes: Number of input terminals of the new element. For the

222

Circuit Schematic Design

Power Modeling Block, this value is the number of total terminals and is read from the DLL file automatically. Output Nodes:Number of output terminals of the new element. For the Power Modeling Block, this value is 0. Hide (menu): Leave this box unchecked. If this box is checked, this element will not appear in the library. Help File: On-line help file associated with this element. Help ID: The ID used in the help map file to link the designated help page. - In the next dialog window, set the new element size as: Width = 5, and Height = 2. Then create an image for this element, or accept the default image. - Click on the buttons Save Image Library and Update Menu. The new element will appear in the library and will be ready to use. The information regarding the number of parameters and the parameter description for the new inductor element is obtained from the DLL file automatically. In this case, the new element will have one parameter as "Inductance". The process of creating the on-line help file is the same as described in the previous section.

6.7

Other Options

6.7.1 Generate and View the Netlist File


To generate the netlist, choose Simulate -> Generate Netlist File. This will create the netlist file with the .cct extension. The netlist file will be saved to the same directory as the schematic file. To view the netlist file, choose Simulate -> View Netlist File.

6.7.2 Set Path


The Set Path function in the Options menu allows users to define additional search paths when loading an external DLL file. For example, if a schematic file uses a DLL file, and this DLL file is placed in a directory other than the schematic directory or the PSIM directory, this directory can be included in PSIM by using the Set Path function. PSIM searches the DLL files in the following order: - PSIM directory - Schematic file directory

Other Options

223

- Directories as defined in the Set Path function. The first time that the DLL file is encountered, it will be loaded. For example, assume that the PSIM program files are in C:\PSIM, the schematic file is in C:\TEMP; and the directory as defined in the Set Path function is C:\TEMPDLL. The DLL file can be in one of the three places: - C:\PSIM - C:\TEMP - C:\TEMPDLL

6.7.3 Settings
Grid display, rubber band feature, text fonts, simulation warning, and colors can be set in the Settings... in the Option menu. Before a circuit is printed, its position on the paper can be viewed by selecting Print Page Border in the Settings... option. If a circuit is split into two pages, it can be moved into one single page. If the circuit is too big to fit in one page, one can zoom out and reduce the circuit size by clicking the Zoom Out button. Print page legend, such as company name, circuit title, designers name, date, etc., can be specified by choosing Print Page Setup in the File menu. It can be disabled in the Settings... option. Also in the Settings... option, if Disable simulation warning messages is checked, warning messages generated during the simulation will be suppressed. Otherwise, warning messages will be shown before waveforms are displayed in SIMVIEW.

6.7.4 Printing the Circuit Schematic


The circuit schematic can be printed from a printer by choosing Print in the File menu. It is also possible to print the selected region of a circuit by choosing Print Selected. The schematic can also be saved to the clipboard which can be imported into a word processor (such as Microsoft Word). By default, the schematic image is saved in monochrome in order to save memory space. One can save the image in color by selecting Edit/Copy to Clipboard/Color.

224

Circuit Schematic Design

7
Waveform Processing
SIMVIEW is PSIMs waveform display and post-processing program. The following shows simulation waveforms in the SIMVIEW environment.

SIMVIEW reads data in either ASCII text format or SIMVIEW binary format. The following shows a sample text data file:
Time Isa 5.000000000E-006 1.000000000E-005 1.500000000E-005 2.000000000E-005 2.500000000E-005 ... ... ... ... Isc Isb Tem_IM 0.000000000E+000 0.000000000E+000 0.000000000E+000 7.145888260E-048 0.000000000E+000 0.000000000E+000 0.000000000E+000 1.082981714E-046 0.000000000E+000 0.000000000E+000 0.000000000E+000 5.408644357E-046 1.139566166E-001 -2.279132474E-001 1.139566166E-001 1.613605209E-017 5.072914178E-001 -1.014582858E+000 5.072914178E-001 3.598226665E-015

Functions in each menu are explained in the following sections.

Other Options

225

7.1

File Menu
The File Menu has the following functions: Open Merge Re-Load Data Save As Load a data file in ASCII text format (with .txt extension) or SIMVIEW binary format (with .smv extension) Merge another data file with the existing data file for display Re-load data from the same text file Save the waveforms to either binary data format or text format. When saving to the binary format, the current settings are also saved. In the FFT display, this will save the FFT results to a text file specified by the user. Print Print Setup Print Page Setup Print Preview Exit Print the waveforms Set up the printer Set up the hardcopy printout size Preview the printout Quit SIMVIEW

When the data of a file are currently being displayed, if new data is available, by selecting Re-Load Data, new data will be loaded and waveforms will be re-drawn. By using the Merge function, data from multiple files can be merged together for display. For example, if one file contains the curves I1 and I2, and another file contains the curves V1 and V2, all four curves can be merged and displayed on one screen. If the second file also contains a curve with the same name I1, it will be modified to I1_1 automatically.

7.2

Edit Menu
The Edit Menu has the following functions: Undo Go back to the previous X and Y axis settings Copy to Clipboard Copy the waveforms to the clipboard Note that the Copy to Clipboard function will copy the displayed waveforms on the screen to the clipboard. To save the memory and have the waveform image in black & white, first go to Option and de-select Color to have a black & white display, then copy the waveform to the clipboard.

226

Waveform Processing

7.3

Axis Menu
The Axis Menu has the following functions: X Axis Y Axis Change the settings of the X axis Change the settings of the Y axis

Choose X-Axis Variable By default, the first column of the data is selected as the X axis. However, other columns can also be selected as the X axis through this function. The dialog box of the X/Y axis settings are shown below.

If the Auto-Scale and Auto-Grid boxes are checked, the maximum data range will be selected and the number of axis divisions will be automatically determined. Both the data range and grid division, however, can be manually set. By default, the first column of the data, which is usually Time, is used as the X axis. However, any other column of the data can be used as the X axis. For example, the following figure shows a sine waveform as the X axis versus a cosine waveform in the Y axis.

Axis Menu

227

7.4

Screen Menu
The Screen Menu has the following functions: Add/Delete Curves Add or delete curves from the selected screen Add Screen Delete Screen Add a new screen Delete the selected screen

A screen is selected by clicking the left mouse on top of the screen. The property dialog window of curves is shown below.

Edit Box

All the data variables available for display are in the Variables Available box, and the variables currently being displayed are in the Variables for Display box. After a variable is highlighted in the Variables Available box, it can be added to the Variables for Display box by clicking on Add ->. Similarly, a variable can be removed from display by highlighting the variable and clicking on <- Remove. In the Edit Box, an mathematical expression can be specified. A mathematical expression can contain brackets and is not case sensitive. The following math functions are allowed: + * / ^ addition subtraction multiplication division to the power of [Example: 2^3 = 2*2*2]

228

Waveform Processing

SQRT SIN COS TAN ATAN EXP LOG LOG10 ABS SIGN AVG INT

square-root function sine function cosine function tangent function inverse tangent function exponential (base e) [Example: EXP(x) = ex] logarithmic function (base e) [Example: LOG(x) = ln (x)] logarithmic function (base 10) absolute function sign function [Example: SIGN(1.2) = 1; SIGN(-1.2)=-1] average function integration function

Type this expression in the Edit Box, and click on Add ->. Highlight the expression on the right, click on <- Remove, and the expression will be moved into the Edit Box for further editing. Also in the property dialog window, in the Curves tab, the curve properties, such as color, line thickness, and marker symbol, can be defined. In the Screen tab, the screen properties, such as foreground/background colors, grid color, and font size/type, can be defined.

7.5

Measure Menu
The Measure Menu has the following functions: Measure Max Min Next Max Next Min Avg Avg(|x|) rms Enter the measure mode. Find the global maximum of a selected curve Find the global minimum of a selected curve Find the next local maximum of a selected curve Find the next local minimum of a selected curve Calculate the average of a selected curve within the selected time Calculate the average of the absolute value of a selected curve within the selected time Calculate the rms value of a selected curve within the selected time

Measure Menu

229

A region is selected by pressing the left button of the mouse and, at the same time, drag the mouse. The Measure function allows the measurement of waveforms. After Measure is selected, the measurement dialog box will appear. By clicking the left mouse, a line will appear and the values of the waveforms will be displayed. By clicking the right mouse, another line will appear and the different between the current position and the previous position, which is marked by the left mouse, will be measured. A SIMVIEW window with the measurement boxes in these two modes are shown below.

Left mouse click

Right mouse click

Once Measure is selected, an individual curve can be selected by clicking on the pulldown menu on the Measure toolbar. The functions, Max, Min, Next Max, Next Min, Avg, and rms, can be used to evaluate the curve. Note that these functions are only enabled in the Measure mode.

7.6

View Menu
The View Menu has the following functions: Zoom Re-Draw Escape To zoom into a selected region To re-draw the waveform using the auto-scale To escape from the Zoom or Measure mode

230

Waveform Processing

Standard Toolbar Measure Toolbar Status Bar

To enable/disable standard toolbar To enable/disable measure toolbar To enable/disable status bar

7.7

Option Menu
The Option Menu has the following functions: FFT Time Grid Color Perform the Fast Fourier Transform analysis Switch from the frequency spectrum display to time domain display Enable or disable the grid display Set the curves to be either Color (default) or Black and White

By selecting FFT, the harmonic amplitudes of time domain waveforms can be calculated and displayed. Note that, in order to obtain correct FFT results, the simulation should reach the steady state, and the simulation data should be restricted (using the manual range setting in the X Axis function) to have the integer number of the fundamental period.

7.8

Label Menu
The Label Menu has the following functions: Text Line Dotted Line Arrow Place text on the screen Draw a line Draw a dotted line Draw a line with arrow

To draw a line, first select Line from the Label menu. Then click the left mouse at the position where the line begins, and drag the mouse while keeping the left button pressed. Dotted lines and lines with arrows are drawn in the same way. If one is in the Zoom or Measure mode, and wishes to edit a text or a label, one should first escape from the Zoom/Measure mode by selecting Escape in the View menu.

7.9

Exporting Data
FFT results can be saved to a text file. Both simulation results (*.txt) and FFT results (*.fft) are in text format and can be edited using a text editor (such as Microsoft

Option Menu

231

NotePad), or exported to other software (such as Microsoft Excel). For example, to load a simulate result file chop-1q.txt in Microsoft Excel, follow these steps: - In Microsoft Excel, select Open from the File menu. Open the file chop1q.txt. - In the dialog window Text Import Wizard - Step 1 of 3, under Original data type, choose Delimited. Click on Next. - In the dialog window Text Import Wizard - Step 2 of 3, under Delimiters, choose Space. Click on Next. - In the dialog window Text Import Wizard - Step 3 of 3, under Column data format, choose General. Click on Finish.

232

Waveform Processing

8
Error/Warning Messages and Other Simulation Issues
8.1 Simulation Issues

8.1.1 Time Step Selection


PSIM uses the fixed time step in the simulation. In order to assure accurate results, the simulation time step should be properly chosen. The factors that limit the time step in a circuit include the switching period, widths of pulses or square waveforms, and intervals of fast transients. It is recommended that the time step should be at least one magnitude smaller than the smallest of the above.

8.1.2 Propagation Delays in Logic Circuits


The logic elements in PSIM are ideal, i.e. there is no propagation delay. If a logic circuit uses the propagation delays for its operation, a function block in PSIM, called the Time Delay block, needs to be added to represent the effect of the propagation delay. To illustrate this, take a two-bit counter circuit as an example.
Q0 Q1 Q0 Q1

clock

clock

1V

1V

In the circuit on the left, the initial values of both Q0 and Q1 are assumed to be zero. At the clock rising edge, Q0 will change to 1. Without delay, the position of Q1, which should remain at 0, will toggle to 1 at the same time. To prevent this, a time delay element with the delay period of one time step needs to be

Simulation Issues

233

inserted between Q0 and the input (J) of the second flip-flop.

8.1.3 Interface Between Power and Control Circuits


In PSIM, power circuits are represented in the discrete circuit form, and control circuits are represented in function block diagram. Power circuit components, such as RLC branches, switches, transformers, mutual inductors, current sources, floating voltage sources, and all types of controlled sources are not allowed in the control circuit. Similarly, control circuit components, such as logic gates, PI controllers, lookup tables, and other function blocks, are not allowed in the power circuit. If there is a direct connection between the power circuit and the input of a control circuit element, a voltage sensor will be automatically inserted by the program. Similarly, if there is a direct connection between the output of a control circuit element and the power circuit, a control-power interface block will be automatically inserted. This is illustrated in the examples below.

Comparator

Comparator

Transfer Function op. amp. op. amp.

Transfer Function

It should be noted that, in PSIM, the power circuit and the control circuit are solved separately. There is one time step delay between the power and the control circuit solutions.

8.1.4 FFT Analysis


When using FFT for the harmonic analysis, one should make sure that the following requirements are satisfied: - The waveforms have reached the steady state;

234

Error/Warning Messages and Other Simulation Issues

- The length of the data selected for FFT should be the multiple integer of the fundamental period. For a 60-Hz waveform, for example, the data length should be restricted to 16.67 msec. (or multiples of 16.67 msec.). Otherwise, the FFT results will be incorrect. The data is selected by clicking on X Axis in SIMVIEW, de-selecting Auto-scale in Range, and specifying the starting time and the final time. The FFT analysis is only performed on the data that are displayed on the screen. Note that the FFT results are discrete. The FFT results are determined by the time interval between two consecutive data points, t, and the data length Tlength. The data point interval t is equal to the simulation time step multiplied by the print step. In the FFT results, the frequency incremental step will be 1/Tlength, and the maximum frequency will be 1/(2*t). For example, if you take the FFT of a 1-kHz square waveform with a data length of 1 ms and a data point interval of 10 us, that is, Tlength = 1 ms, and t = 10 us, the frequency incremental step will be: f = 1/Tlength = 1 kHz. The maximum frequency will be: fmax = 1/(2*t) = 50 kHz.

8.2

Error/Warning Messages
The error and warning messages are listed in the following.
E-1 Input format errors occurred in the simulation.

It may be caused by one of the following: - Incorrect/Incomplete specifications - Wrong input for integers and character strings Make sure that the PSIM library is not modified, and the PSIM simulator is upto-date. In the circuit file, character strings should be included between two apostrophes (like test). Also, make sure an integer is specified for an integer variable. The specification of a real number (like 3. instead of 3) for an integer will trigger the error message.
E-2 Error message: The node of an element is floating.

This can also be caused by a poor connection in PSIM. When drawing a wire between two nodes, make sure that the wire is connected to the terminal of the element.

Error/Warning Messages

235

W-1

Warning!!! The program failed to converge after 10 iterations when determining switch positions. The computation continues with the following switch positions: ... ...

This warning occurs when the program fails to converge when determining switching positions. Since the computation continues based on the switch positions at the end of the 10th iteration, results could be inaccurate. One should be cautious when analyzing the results. There are many factors that cause this problem. The following measures can be taken to isolate and solve the problem: - Check the circuit and make sure the circuit is correct. - Check the switch gating signals. - Connect small resistors/inductors in series with switches and voltage sources.
W-2 Warning!!! The program did not reach the steady state after 60 cycles when performing the ac sweep.

This warning occurs when the program fails to reach the steady state after 60 cycles when performing the ac sweep. The cause of the problem could be that the system is poorly damped at that particular frequency or the signal amplitude is too small. You may try the following to isolate and solve the problem: - Run the time-domain simulation with the excitation source at that frequency and see if time-domain waveforms are oscillatory. - Increase the excitation voltage amplitude for larger signal level, or - Reduce the time step for better accuracy and resolution.

8.3

Debugging
Some of the approaches in debugging a circuit is discussed in the following. Symptom: Simulation results show sudden changes (discontinuity) of inductor currents and capacitor voltages. Solution: This may be caused by the interruption of inductor current path and short-circuit

236

Error/Warning Messages and Other Simulation Issues

of capacitor (or capacitor-voltage source) loops. Check the switch gating signals. If necessary, include overlap or dead time pulses to avoid open-circuit or shooting-through. If an initial current is assigned to an inductor, initial switch positions should be set such that a path is provided for the current flow. Otherwise, the inductor current will be forced to start from zero. Symptom: Simulation waveforms look incorrect or inaccurate, or the waveform resolution is poor. Solution: This may be caused by two reasons. One is the time step. Since PSIM uses the fixed time step during the entire simulation, one should make sure that the time step is sufficiently small. As a rule of thumb, the time step should be several tens times smaller than the switching period. Another reason is the problem of waveform display. One should make sure that the print step is not too big. To display all the data points, set the print step to 1.

Debugging

237

238

Error/Warning Messages and Other Simulation Issues

You might also like