Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

International Limited: Certificate of Visual Examination and Mpi

Download as pdf or txt
Download as pdf or txt
You are on page 1of 25

JC International Limited

RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10123 Identification Number Qty

24/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE

DFP 01

1pc

Fabricated Padeye SWL: 1t

Date of next Examination: 23/04/13 LOCATION: DRILL FLOOR


SPECIFICATION : BS EN 13001 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: Fit for use


Name and address of equipment owner:

No defect as at the time of inspection.

Address of premises where Test / Examination was held:

OANDO ENERGY SERVICES

TEAMWORK

We hereby certify that on 24/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination
Revision No: 01

Name of Inspector: KELVIN OSUJI Conducting: Examination only


Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10124 Identification Number Qty

24/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE

DFP 03

1pc

Fabricated Padeye SWL: 1t

Date of next Examination: 23/04/13 LOCATION: DRILL FLOOR


SPECIFICATION : BS EN 13001 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: Fit for use


Name and address of equipment owner:

No defect as at the time of inspection.

Address of premises where Test / Examination was held:

OANDO ENERGY SERVICES

TEAMWORK

We hereby certify that on 24/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination
Revision No: 01

Name of Inspector: KELVIN OSUJI Conducting: Examination only


Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10125 Identification Number Qty

24/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE

DFP 04

1pc

Fabricated Padeye SWL: 1t

Date of next Examination: 23/04/13 LOCATION: DRILL FLOOR


SPECIFICATION : BS EN 13001 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: Fit for use


Name and address of equipment owner:

No defect as at the time of inspection.

Address of premises where Test / Examination was held:

OANDO ENERGY SERVICES

TEAMWORK

We hereby certify that on 24/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination
Revision No: 01

Name of Inspector: KELVIN OSUJI Conducting: Examination only


Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10126 Identification Number Qty

24/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE

DFP 05

1pc

Fabricated Padeye SWL: 1t

Date of next Examination: 23/04/13 LOCATION: DRILL FLOOR


SPECIFICATION : BS EN 13001 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: Fit for use


Name and address of equipment owner:

No defect as at the time of inspection.

Address of premises where Test / Examination was held:

OANDO ENERGY SERVICES

TEAMWORK

We hereby certify that on 24/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination
Revision No: 01

Name of Inspector: KELVIN OSUJI Conducting: Examination only


Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10127 Identification Number Qty

24/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE

DFP 06

1pc

Fabricated Padeye SWL: 1t

Date of next Examination: 23/04/13 LOCATION: DRILL FLOOR


SPECIFICATION : BS EN 13001 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: Fit for use


Name and address of equipment owner:

No defect as at the time of inspection.

Address of premises where Test / Examination was held:

OANDO ENERGY SERVICES

TEAMWORK

We hereby certify that on 24/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination
Revision No: 01

Name of Inspector: KELVIN OSUJI Conducting: Examination only


Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10213 Identification Number Qty

26/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE
BP 01 1

A steel Fabricated Padeye


SWL: 3.5 t

Date of next Examination: 25/04/2013

LOCATION: STBD BOP AREA


SPECIFICATION: MPI METHOD:

BS EN 13001
Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner:

Address of premises where Test / Examination was held:

Oando Energy Services


We hereby certify that on inspection. Fit for use Signature of Inspector: Conducting Examination

Team Work
26/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of Name of Inspector: KELVIN OSUJI Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10214 Identification Number Qty

26/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE
BP 02 1

A steel Fabricated Padeye


SWL: 3.5 t

Date of next Examination: 25/04/2013

LOCATION: STBD BOP AREA


SPECIFICATION: MPI METHOD:

BS EN 13001
Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner:

Address of premises where Test / Examination was held:

Oando Energy Services


We hereby certify that on inspection. Fit for use Signature of Inspector: Conducting Examination

Team Work
26/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of Name of Inspector: KELVIN OSUJI Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10215 Identification Number Qty

26/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE
BP 03 1

A steel Fabricated Padeye


SWL: 3.5 t

Date of next Examination: 25/04/2013

LOCATION: STBD BOP AREA


SPECIFICATION: MPI METHOD:

BS EN 13001
Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner:

Address of premises where Test / Examination was held:

Oando Energy Services


We hereby certify that on inspection. Fit for use Signature of Inspector: Conducting Examination

Team Work
26/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of Name of Inspector: KELVIN OSUJI Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10216 Identification Number Qty

26/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE
BP 04 1

A steel Fabricated Padeye


SWL: 3.5 t

Date of next Examination: 25/04/2013

LOCATION: STBD BOP AREA


SPECIFICATION: MPI METHOD:

BS EN 13001
Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner:

Address of premises where Test / Examination was held:

Oando Energy Services


We hereby certify that on inspection. Fit for use Signature of Inspector: Conducting Examination

Team Work
26/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of Name of Inspector: KELVIN OSUJI Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10217 Identification Number Qty

26/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE
MUD 2 1

A steel Fabricated Padeye


SWL: 1t

Date of next Examination: 25/04/2013

LOCATION: MUD PUMP ROOM


SPECIFICATION: MPI METHOD:

BS EN 13001
Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner:

Address of premises where Test / Examination was held:

Oando Energy Services


We hereby certify that on inspection. Fit for use Signature of Inspector: Conducting Examination

Team Work
26/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of Name of Inspector: KELVIN OSUJI Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10218 Identification Number Qty

26/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE
MUD 3 1

A steel Fabricated Padeye


SWL: 1t

Date of next Examination: 25/04/2013

LOCATION: MUD PUMP ROOM


SPECIFICATION: MPI METHOD:

BS EN 13001
Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner:

Address of premises where Test / Examination was held:

Oando Energy Services


We hereby certify that on inspection. Fit for use Signature of Inspector: Conducting Examination

Team Work
26/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of Name of Inspector: KELVIN OSUJI Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10219 Identification Number Qty

26/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE
MUD 4 1

A steel Fabricated Padeye


SWL: 1t

Date of next Examination: 25/04/2013

LOCATION: MUD PUMP ROOM


SPECIFICATION: MPI METHOD:

BS EN 13001
Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner:

Address of premises where Test / Examination was held:

Oando Energy Services


We hereby certify that on inspection. Fit for use Signature of Inspector: Conducting Examination

Team Work
26/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of Name of Inspector: KELVIN OSUJI Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10220 Identification Number Qty

26/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE
MUD 7 1

A steel Fabricated Padeye


SWL: 1t

Date of next Examination: 25/04/2013

LOCATION: MUD PUMP ROOM


SPECIFICATION: MPI METHOD:

BS EN 13001
Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner:

Address of premises where Test / Examination was held:

Oando Energy Services


We hereby certify that on inspection. Fit for use Signature of Inspector: Conducting Examination

Team Work
26/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of Name of Inspector: KELVIN OSUJI Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

REPORT FOR VISUAL AND MAGNETIC PARTICLE INSPECTION


Report No. 10221

Equipment Description: Equipment ID:

Fabricated Padeye MPE-1

Location:

Mast (Team Work)

Specification: Defect Found: Name of Client:

ASTM E 1444 None Oando Energy Services

Inspectors Name/Qualification KELVIN OSUJI


SNT LEVEL II MT, PT, UT LEEA, Lifting Equipment Insp.

Signature/Date

23/10/2012

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

REPORT FOR VISUAL AND MAGNETIC PARTICLE INSPECTION


Report No. 10222

Equipment Description: Equipment ID:

Fabricated Padeye MPE-2

Location:

Mast (Team Work)

Specification: Defect Found: Name of Client:

ASTM E 1444 None Oando Energy Services

Inspectors Name/Qualification KELVIN OSUJI


SNT LEVEL II MT, PT, UT LEEA, Lifting Equipment Insp.

Signature/Date

23/10/2012

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10223 Identification Number Qty

23/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE
CBPI 19 1

A steel Fabricated Padeye


SWL: 10 t

Date of next Examination: 22/04/2013

LOCATION: MAST
SPECIFICATION: MPI METHOD:

BS EN 13001
Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner:

Address of premises where Test / Examination was held:

Oando Energy Services


We hereby certify that on inspection. Fit for use Signature of Inspector: Conducting Examination

Team Work
23/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of Name of Inspector: KELVIN OSUJI Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10224 Identification Number Qty

23/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE
CBPI 18 1

A steel Fabricated Padeye


SWL: 10 t

Date of next Examination: 22/04/2013

LOCATION: MAST
SPECIFICATION: MPI METHOD:

BS EN 13001
Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner:

Address of premises where Test / Examination was held:

Oando Energy Services


We hereby certify that on inspection. Fit for use Signature of Inspector: Conducting Examination

Team Work
23/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of Name of Inspector: KELVIN OSUJI Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10225 Identification Number Qty

23/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE
CBPI 05 1

A steel Fabricated Padeye


SWL: 10 t

Date of next Examination: 22/04/2013

LOCATION: MAST
SPECIFICATION: MPI METHOD:

BS EN 13001
Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner:

Address of premises where Test / Examination was held:

Oando Energy Services


We hereby certify that on inspection. Fit for use Signature of Inspector: Conducting Examination

Team Work
23/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of Name of Inspector: KELVIN OSUJI Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10226 Identification Number Qty

23/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE
CBPI 13 1

A steel Fabricated Padeye


SWL: 10 t

Date of next Examination: 22/04/2013

LOCATION: MAST
SPECIFICATION: MPI METHOD:

BS EN 13001
Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner:

Address of premises where Test / Examination was held:

Oando Energy Services


We hereby certify that on inspection. Fit for use Signature of Inspector: Conducting Examination

Team Work
23/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of Name of Inspector: KELVIN OSUJI Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10227 Identification Number Qty

25/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE
SLP 01 1

A steel Fabricated Padeye


SWL: 1t

Date of next Examination: 24/04/2013

LOCATION: MAST
SPECIFICATION: MPI METHOD:

BS EN 13001
Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner:

Address of premises where Test / Examination was held:

Oando Energy Services


We hereby certify that on inspection. Fit for use Signature of Inspector: Conducting Examination

Team Work
25/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of Name of Inspector: KELVIN OSUJI Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

10228 Identification Number Qty

25/10/2012

KELVIN OSUJI

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

PADEYE
SLP 02 1

A steel Fabricated Padeye


SWL: 1t

Date of next Examination: 24/04/2013

LOCATION: MAST
SPECIFICATION: MPI METHOD:

BS EN 13001
Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner:

Address of premises where Test / Examination was held:

Oando Energy Services


We hereby certify that on inspection. Fit for use Signature of Inspector: Conducting Examination

Team Work
25/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of Name of Inspector: KELVIN OSUJI Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

REPORT FOR VISUAL AND MAGNETIC PARTICLE INSPECTION


Report No. 10229

Equipment Description:

Fabricated Padeye

Equipment ID:

MBP 1

Location:

Monkey Board (Team Work)

Specification: Defect Found: Name of Client:

ASTM E 1444 None Oando Energy Services

Inspectors Name/Qualification KELVIN OSUJI


SNT LEVEL II MT, PT, UT LEEA, Lifting Equipment Insp.

Signature/Date

25/10/2012

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

REPORT FOR VISUAL AND MAGNETIC PARTICLE INSPECTION


Report No. 10230

Equipment Description:

Fabricated Padeye

Equipment ID:

MBP 2

Location:

Monkey Board (Team Work)

Specification: Defect Found: Name of Client:

ASTM E 1444 None Oando Energy Services

Inspectors Name/Qualification KELVIN OSUJI


SNT LEVEL II MT, PT, UT LEEA, Lifting Equipment Insp.

Signature/Date

25/10/2012

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

REPORT FOR VISUAL AND MAGNETIC PARTICLE INSPECTION


Report No. 10231

Equipment Description:

Fabricated Padeye

Equipment ID:

MBP 3

Location: Specification: Defect Found: Name of Client:

Monkey Board (Team Work) ASTM E 1444 None Oando Energy Services

Inspectors Name/Qualification KELVIN OSUJI


SNT LEVEL II MT, PT, UT LEEA, Lifting Equipment Insp.

Signature/Date

25/10/2012

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

REPORT FOR VISUAL AND MAGNETIC PARTICLE INSPECTION


Report No. 10232

Equipment Description:

Fabricated Padeye

Equipment ID:

MBP 4

Location:

Monkey Board (Team Work)

Specification: Defect Found: Name of Client:

ASTM E 1444 None Oando Energy Services

Inspectors Name/Qualification KELVIN OSUJI


SNT LEVEL II MT, PT, UT LEEA, Lifting Equipment Insp.

Signature/Date

25/10/2012

You might also like