01 Saveris Gen en
01 Saveris Gen en
01 Saveris Gen en
Quick overview of system components Long-term memory provides safety and independence from the PC Alarm even without running PC - via LED - via relay output - via SMS Radio probe and Ethernet probe can be combined in one system
Diagram Start Copy Paste Clipboard Edit .. Open Rename Delete Edit Evaluation Options New group Template Day Month Diagram Table Alarms View Font Font Font size Arial 10 _Style
Data
Data Group 0 C C C Group 1 C C
Original size
October 2007 M T W T F S S
November 2007 M T W T F S S
Today
Simple installation and configuration within few minutes Alarm via e-mail or directly on the screen Efficiency by means of central data storage of all measurement data Automatic creation of PDF reports
testo Saveris is ideally suited for and documentation of temperature or humidity data in production, quality assurance and R&D as well as in buildings Monitoring the storage climate of temperature and humidity sensitive products, e.g. valuable inventory, medicines and foodstuffs the foodstuff cooling chain
Precise measurement of temperature and humidity values The simplest probe logon at commissioning Manual start or read out no longer required Radio probe: simple connection without routing cables Safety through bidirectional radio and memory capacity in the probe Optimized battery concept for long running life Numerous probe versions tailored to every application
You have time for the basics. testo Saveris measures, documents centrally and issues alarms if limit values are exceeded.
With testo Saveris, I have the perfect overview over all temperature and humidity data in processes and in the environment. The immediate issue of alarms provides me with important safety.
With testo Saveris we finally have a system that automatically documents our room climate. With this, I know that our most prized inventory is being stored in a secure climate, and all this without cabling.
1
Hier konfigurieren Sie die angeschlossenen Messfhler. Liste der im System registrierten Fhler Seriennr.
1413872 1413855 1413842
K. Einheit
1 1 1 C C C
Name
Khlraum 14 Theke 1 Khltruhe
Untergrenze
-14.0 2.0 -20.0
Obergrenze
-5.0 7.0 -18.0
TE-Typ
Namen und Grenzwerte vergeben. Einige Gerte erfordern eine manuelle Eingabe des Thermoelement (TE) Typs.
< Zurck
Weiter >
Abbrechen
2
Diagram Start Copy Paste Clipboard Edit Open Rename Organisieren Edit Group 0 Betriebsart Options Schliessen Delete Template Online Offline Online Start Online Stop Messung steuern Online Evaluation Day Month Diagram Histogramm Zahlenfeld View Grafik Table Alarms _Style
Data
Data Group 0 C C C Group1 C C October 2007 M T W T F S S
Original size
Various probes can be compiled into groups. Logical units according to the measurement task are thus formed. The measurement data view over days, weeks or months is freely definable. The integrated calendar offers practical assistance here.
November 2007 M T W T F S S
December 2007
Datum
(C) Raum 2
(C) Raum 3
M T W T F S S
3
Daily report
Cold storage house zone: Hourly mean values on 03.08.2007
Time C freezer 1 %RH cold room 1 C refrigerator C drinks C freezer 2 C freezer 3 C freezer 4
Automated documentation
Form and time of the reporting are predefined once. The creation and saving of reports as a PDF file now takes place automatically in accordance with the set conditions. The files are therefore ready to be printed at any time.
4
Number field Start Copy Paste Clipboard Edit Open Rename Organizing Edit Group 0 Operating Options Close Delete Template Online Offline Online start Online stop Control Online Evaluation Day Month Diagram Histogram Number View Graphic Table Alarms _Style
Data
Data Group 0 C C C Group 1 C C
21 C 48 %RH
October 2007 M T W T F S S
November 2007 M T W T F S S
26 C 38 %RH
December 2007 M T W T F S S
41 C 22 %RH
Today
SBE Simple installation and configuration Diagrams/tables/alarm overview/PDF reports Calendar management Representation of probe group Transmission of alarms (e-mail, SMS, relay) Comprehensive alarm management Constant monitoring in PC continuous operation Measurement data on background photo of locations Integration into network (client-server)
PROF
The base is the heart of testo Saveris and can save 40,000 readings independent of the PC. The system data and alarms are visible via the display of the Saveris base.
Display for showing alarms and system data Large data memory Issue of alarms via LED/relay SMS alarm (optional) Emergency battery integrated Up to 150 probes can be connected Connection option via USB or Ethernet
Registration
Probes Router Converter
Technical data Memory Dimensions Weight Protection class Material/Housing Radio frequency Power supply (absolutely necessary) Rech. batt. Oper. temp. Storage temp. Display Interfaces Connectable radio probe 40,000 values per channel (total max. 10,160,000 values) 225 x 150 x 49 mm Approx. 1510 g IP42 Diecast zinc / plastic 868 MHz / 2.4 GHz 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, power consumption < 4 W Li-ion battery (for data back-up and for emergency SMS with failure of the power supply) -10 to +50 C -40 to +85 C graphical display, 4 control keys USB, radio, Ethernet max. 15 probes can be directly connected via radio interface, max. 150 total via radio/router/converter/Ethernet, max. 254 channels max. 1 A, max. 30 W, max. 60/25 V DC/AC, NC or NO contact 850/900/1800/1900 MHz not valid for Japan and South Korea Table base and wall bracket included
Ordering data Saveris base, radio frequency 868 MHz Part no. 0572 0120 Saveris base, radio frequency 2.4 GHz 2.4 GHz 2.4 GHz Saveris base, radio frequency 868 MHz, GSM module integrated (for SMS alarm) Part no. 0572 0121 Saveris base, radio frequency 2.4 GHz, GSM module integrated (for SMS alarm) Part no. 0572 0161
868 MHz
No mains units or antennas with magnetic base are contained in this ordering data.
Note on the radio frequencies 868 MHz: EU countries and certain other countries (e.g. CH, NOR) 2.4 GHz: non-EU countries (country list can be called up under www.testo.com/saveris )
868 MHz
Accessories Power supply Radio Ethernet Battery for radio probe (4 AA alkali manganese mignon batteries) Battery for radio probe for use below -10 C (4 Energyzer L91 Photo lithium) 100-240 V DC mains unit; for testo Saveris base, router, converter, Ethernet probe Radio Radio Mains unit (rail mounting) 90 to 264 VAC/ 24 VDC (2.5A) Mains unit (desk-top) 110 to 240 VAC/24 VDC (350mA) Other features Magnetic foot aerial with 3 m cable, for base with 1 GSM module Alarm module (visual + acoustic), can be connected to base alarm relay, diam. 70 x 164 mm, 24 V AC/DC or 320 mA, steady on: red, steady tone: buzzer approx. 2.4 kHz
Part no. Part no. 0515 0414 0515 0572 0554 1096 0554 1749 0554 1748 Part no. 0554 0524
Saveris router
Dimensions Weight Power supply Approx. 85 x 100 x 38 mm Approx. 180 g 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, power consumption < 0.5 W -20 to +50 C -40 to +85 C Kunststoff IP54 Radio max. 5 included Saveris router, 868 MHz, radio transmission medium
Saveris converter
Approx. 85 x 100 x 35 mm Approx. 190 g 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, power consumption < 2 W -20 to +50 C -40 to +85 C Kunststoff IP54 Radio, Ethernet max. 15 included Saveris converter, 868 MHz, converts the radio transmission medium to Ethernet Part no. 0572 0118 Saveris converter, 2.4 GHz, converts the radio transmission medium to Ethernet Part no. 0572 0158
0629 6666 Part no. 0572 0180 0572 0181 0572 0183 On request Part no. 0520 0151
Oper. temp. Storage temp. Material/Housing Protection class Interfaces Connectable radio probe Wall bracket Versions 868 MHz
Software SBE software, incl. USB connecting cable base-PC PROF software, incl. USB connecting cable base-PC Saveris adjustment software incl. connection cable for wireless and Ethernet probes Measurement data view via Internet Calibration Certificates
Part no. 0572 0119 Saveris router, 2.4 GHz, radio transmission medium
ISO calibration certificate/temperature; temp. data logger; calibration points -18C; 0C; +60C DKD calibration certificate/temperature; temp. data logger; cal. points -20C; 0C; +60C ISO cal. cert./humidity; humidity data logger; calibration points 11.3%RH and 75.3%RH at +25C DKD calibration cert./humidity; humidity data logger; cal. points 11.3%RH and 75.3%RH at +25C
2.4 GHz
0520 0261
0520 0076
0520 0246
Note on the radio frequencies 868 MHz: EU countries and certain other countries (e.g. CH, NOR) 2.4 GHz: non-EU countries (country list can be called up under www.testo.com/saveris ) Magnetic foot aerial Alarm module (visual + acoustic), can be connected to base alarm relay
C NTC
81 mm
%RH, C NTC
81 mm 81 mm
NTC
internal
TC
81 mm
internal
external
external
Radio
Probe type Internal sensor Meas. range Accuracy Resolution Probe type Meas. range (Instrument)
Saveris T1
Radio probe with internal NTC
Saveris T2
Radio probe with external probe connection and internal NTC, door contact NTC -35 to +50 C 0.4 C (-25 to +50 C) 0.8 C (remaining range) 0.1 C NTC -50 to +150 C
Saveris T3
2-channel radio probe with 2 external TC probe connections (Choice of TC characteristics)
Saveris Pt
Radio probe with 1 external Pt100 probe connection
Saveris H3
Humidity radio probe
NTC -35 to +50 C 0.4 C (-25 to +50 C) 0.8 C (remaining range) 0.1 C
TC type K
External probe
TC type J
Accuracy (Instrument)
0.5 C or 0.5% of mv
at 25 C 0.1 C (0 to +60 C) 0.2 C (-100 to +200 C) 0.5 C (remaining range) 0.01 C 1 Pt100 via mini-DIN socket
Resolution Connection
0.1 C NTC via mini-DIN socket, door contact connection cable included in delivery (1.80 m)
868 MHz
Dimensions (housing): Weight Battery type Battery life Material/Housing Protection class IP68 Radio frequency Measuring rate Conformity with standards Oper. temp. Storage temp. Display (optional) Transmission distance Wall bracket Versions Version without Saveris T1 display Part no. 0572 1110 Version with display Version without display Version with display Saveris T1 D Part no. 0572 1120 Saveris T1 Part no. 0572 1150 Saveris T1 D Part no. 0572 1160
80 x 85 x 38 mm Approx. 240 g 4 AA batteries Battery life at +25 C, 3 years; for freezer applications, 3 years with L91 Photo lithium Energyzer batteries Kunststoff IP68 IP54 IP68 IP42 868 MHz / 2.4 GHz Standard 15 min, 1 min to 24 h can be set DIN EN 12830 -35 to +50 C -20 to +50 C -40 to +55 C LCD, 2 lines; 7-segment with symbols approx. 300 m free field at a frequency of 868 MHz, approx. 100 m free field at a frequency of 2.4 GHz included Saveris T2 Part no. 0572 1111 Saveris T2 D Part no. 0572 1121 Saveris T2 Part no. 0572 1151 Saveris T2 D Part no. 0572 1161 Saveris T3 Part no. 0572 9112 Saveris T3 D Part no. 0572 9122 Saveris T3 Part no. 0572 9152 Saveris T3 D Part no. 0572 9162 Saveris Pt Part no. 0572 7111 Saveris Pt D Part no. 0572 7121 Saveris Pt Part no. 0572 7151 Saveris Pt D Part no. 0572 7161 Saveris H3 Part no. 0572 6110 Saveris H3 D Part no. 0572 6120 Saveris H3 Part no. 0572 6150 Saveris H3 D Part no. 0572 6160
The AA alkali manganese mignon batteries (0515 0414) are contained in this ordering data.
2.4 GHz
C
Pt 100
external
%RH, C TC
external
%RH NTC
external
%RH NTC
external
100 mm
12 mm
100 mm 12 mm
Ethernet
Probe type Meas. range (Instrument)
Saveris Pt E
Ethernet probe with external Pt100 probe connection Pt100 -200 to +600 C
Saveris T4 E
Saveris H2 E
Saveris H1 E
Humidity Ethernet probe 1%
4-channel Ethernet probe with 4 Humidity Ethernet probe 2 % external TC probe connections TC type T
-200 to +400 C
TC type S
0 to +1760 C
External probe
TC type K at 25 C 0.1 C (0 to +60 C) 0.2 C (-100 to +200 C) 0.5 C (remaining range) 0.01 C 1 Pt100 via mini-DIN socket
Accuracy (Instrument)
0.5 C or 0.5% of mv
Resolution Connection
0.1 C 1 C
0.1% / 0.1 C td
0.1 C
4 TCs via TC socket, max. difference in potential 50 V Approx. 220 g Approx. 85 x 100 x 38 mm Approx. 230 g Approx. 230 g 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals Li-ion Kunststoff IP54 2 s to 24h -20 to +70 C -40 to +85 C LCD, 2 lines; 7-segment with symbols included Saveris H2 E With display Part no. 0572 6192
Dimensions (housing): Weight Power supply (absolutely necessary) Buffer battery Material/Housing Protection class Measuring rate Oper. temp. Storage temp. Display Wall bracket
Approx. 220 g
Saveris H1 E With display Part no. 0572 6191 *not for continuous high-humidity applications
Sintered caps for Saveris H1 E and H2 E Ethernet probes Metal protection cage, 12 mm for humidity probes, for measurement in flow velocities of less than 10 m/s Cap with wire mesh filter, 12 mm Teflon sintered filter, 12 mm, for corrosive substances, high humidity range (longterm measurements), high velocities Stainless steel sintered cap, 12 mm, is screwed onto humidity probe, for measurements at high flow velocities or in contaminated air testo saline pots for control and humidity adjustment of humidity probes, 11.3 %RH and 75.3 %RH with adapter for humidity probe, quick checks or calibration of humidity probe
Part no. 0554 0755 0554 0757 0554 0756 0554 0647 0554 0660
Plug-in probes Robust, Pt100 stainless steel food probe (IP65) Robust, waterproof Pt100 immersion/penetration probe
Pt 100
Illustration
125 mm 4 mm 15 mm 3 mm 114 mm 5 mm 50 mm 3.7 mm
Accuracy Class A (-50 to +300 C), Class B (remaining range) Class A (-50 to +300 C), Class B (remaining range)
t99 10 s
-50 to +400 C
12 s
0609 1273
Fixed cable Connection cable for Pt100 stationary probe with screw terminals (4-wire technology)
0554 0213
Plug-in probes Stationary probe with stainless steel sleeve, TC Type K Robust air probe, T/C Type K
TC
Illustration
40 mm 6 mm
Accuracy Class 2*
t99 20 s
-60 to +400 C
Class 2*
25 s
0602 1793
Magnetic probe, adhesive force approx. 20 N, with magnets, for measurements on metal surfaces, TC Type K Fixed cable
35 mm 20 mm
-50 to +170 C
Class 2*
150 s
0602 4792
75 mm Magnetic probe, adhesive force approx. 10 N, with magnets, for higher temp., for measurements on metal surfaces, TC Type K Conn.: Fixed cable 1.6 m
21 mm
-50 to +400 C
Class 2*
0602 4892
Pipe wrap probe for pipe diameter 5 to 65 mm, with exchangeable measuring head. Meas. range short-term to +280C, TC Type K
Class 2*
5s
0602 4592
395 mm Pipe wrap probe with Velcro strip, for temperature measurement on pipes with diameter up to max. 120 mm, Tmax +120C, TC Type K Conn.: Fixed cable 1.5 m 800 mm Thermocouple with TC adapter, flexible, 800mm long, fibre glass, TC Type K 1.5 mm
-50 to +120 C
Class 1*
90 s
0628 0020
5s 5s 5s 5s 4s
0602 0644 0602 0645 0602 0646 0602 5792 0602 5693
Thermocouple with TC adapter, flexible, 1500mm long, fibre glass, TC Type K Thermocouple with TC adapter, flexible, 1500mm long, Teflon, TC Type K Immersion tip, flexible, TC Type K Immersion measurement tip, flexible, for measurements in air/exhaust gases (not suitable for measurements in smelters), TC Type K
1000 mm 3 mm
The specified accuracy class of the Saveris radio and Ethernet probe is achieved using these external probes.
*According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 C (Type K), Class 2 to -40 to +1200 C (Type K), Class 3 to -200 to +40 C (Type K).
You can find all temperature probes tailored to your application at www.testocelsius.de or in the Stationary measurement solutions catalogue.
NTC
Illustration
35 mm 3 mm
Probe accuracy 0.2 C (-20 to +40 C) 0.4 C (+40.1 to +70 C) 0.2 C (0 to +70 C) 0.5 C (remaining range) 0.2 C (-25 to +74.9 C) 0.4 C (remaining range) 0.2 C (-25 to +74.9 C) 0.4 C (remaining range) 0.2 C (0 to +70 C)
t99 15 s
65
40 mm 6 mm
-30 to +90 C
190 s 5s
0628 7503*
-35 to +80 C
0610 1725*
Conn.: Fixed cable; Cable/length: 6 m Accurate immersion/penetration probe, cable: 1.5 m long, IP 67 Wall surface temperature probe, e.g. to prove damage in building material Conn.: Fixed cable; Cable/length: 3 m Stainless steel NTC food probe (IP65) with PUR cable Waterproof NTC immersion/penetration probe Conn.: Fixed cable
30 mm 125 mm 4 mm 15 mm 3 mm 40 mm 3 mm 3 mm
-35 to +80 C
5s
0628 0006*
8s
0613 2211*
-50 to +150 C
10 s
0613 1212
Pipe wrap probe with Velcro for pipe diameter to max. 75 mm, Tmax. +75C, NTC
300 mm
-50 to +70 C
0613 4611
Conn.: Fixed cable; Cable/length: 1.5 m The specified accuracy class of the Saveris radio and Ethernet probe is achieved using these external probes.
* Probe tested to EN 12830 for suitability in the transport and storage sectors 12) Long-term measurement range +125C, short-term +150C or +140C (2 minutes)
You can find all temperature probes tailored to your application at www.testocelsius.de or in the Stationary measurement solutions catalogue.
Saveris set 1
Saveris set 2
Saveris set 3
Set 1: 868 MHz, consisting of base 0572 0120, 3 NTC radio probes without display 0572 1110, mains unit for base 0554 1096 and SBE software 0572 0180 incl. USB cable
Set 2: 868 MHz, consisting of base 0572 0120, 5 NTC radio probes with display 0572 1120, router 0572 0119, 2 mains units for base and router 0554 1096 and SBE software 0572 0180 incl. USB cable
Set 3: 868 MHz, consisting of base 0572 0121 incl. GSM module for SMS alarm, antenna with magnetic base 0554 0524, 5 NTC radio probes with display 0572 1120, router 0572 0119, 2 mains units for base and router 0554 1096 and SBE software 0572 0180 incl. USB cable
Ordering data Saveris adjustment software incl. connection cable for wireless and Ethernet probes Part no. 0572 0183
Service
testo is a manufacturer of measuring instruments and measuring systems with a global presence, with 27 international subsidiaries and representatives in numerous countries. Naturally, testo also offers you onsite service. For questions regarding testo Saveris, from installation to retrofitting further system components, please refer to your competent contact in your country. You can find an overview of the nearest service location at www.testo.com.