Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Amplifi Ed Low Pressure Sensors: Features

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Amplified Low Pressure Sensors

1 mbar (0.4 In H2O) to 60 In H2O Pressure Sensors

Features
0 to 1 mbar to 0 to 60 In H2O Pressure Ranges Ratiometric 4V Output Temperature Compensated Calibrated Zero and Span

Applications
Medical Instrumentation Environmental Controls HVAC

General Description
The Amplified line of low pressure sensors is based upon a proprietary technology to reduce all output offset or common mode errors. This model provides a ratiometric 4-volt output with superior output offset characteristics. Output offset errors due to change in temperature, stability to warm-up, stability to long time period, and position sensitivity are all significantly reduced when compared to conventional compensation methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured pressure.

These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.

The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.

Physical Dimensions

Equivalent Circuit

8.74 0.344

2.54 0.100 (Typ)

C L

1.27 0.050

Port 0.179"/0.189"
3.18 0.125

Vs

Pin 1 Identifier

10.67 0.420

Port A
5.33 0.210

10.67 0.420 27.43 1.080

Vout

3.56 0.140 3.18 R0.125

Port B

+
Gnd

12.19 0.480

13.97 0.550

20.32 0.800 21.59 0.850

Approvals
MKT DATE MFG DATE ENG DATE QA DATE

As Is

With Change

As Is

With Change

As Is

With Change

As Is

With Change

All Sensors

DS-0024 Rev B

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

0.020" x 0.010" Pin 0.30" minimum length

p 408 225 4314

f 408 225 2079

e www.allsensors.com

all sensors

Pressure Sensor Ratings


Supply Supply Voltage VS Common-mode pressure Lead Temperature, max (soldering 2-4 sec.) +4.5 to +5.5 Vdc -10 to +10 psig 250C

Environmental Specifications
Temperature Ranges Compensated Operating Storage Humidity Limits 5 to 50 C -25 to 85 C -40 to 125 C 0 to 95% RH (non condensing)

Standard Pressure Ranges


Part Number 1 MBAR-D-4V 1 INCH-D-4V 1 INCH-G-4V 2.5 INCH-D-4V 5 INCH-D-4V 5 INCH-G-4V 10 INCH-D-4V 10 INCH-G-4V 20 INCH-D-4V 20 INCH-G-4V 30 INCH-D-4V 30 INCH-G-4V 60 INCH-G-4V Operating Pressure 1 mbar 1 In H2O 0 - 1 In H2O 2.5 In H2O 5 In H2O 0 - 5 In H2O 10 In H2O 0 - 10 In H2O 20 In H2O 0 - 20 In H2O 30 In H2O 0 - 30 In H2O 0 - 60 In H2O Nominal Span 4V 4V 4V 4V 4V 4V 4V 4V 4V 4V 4V 4V 4V Proof Pressure 100 In H2O 100 In H2O 100 In H2O 200 In H2O 200 In H2O 200 In H2O 200 In H2O 200 In H2O 300 In H2O 300 In H2O 500 In H2O 500 In H2O 500 InH2O Burst Pressure 200 In H2O 200 In H2O 200 In H2O 300 In H2O 300 In H2O 300 In H2O 300 In H2O 300 In H2O 500 In H2O 500 In H2O 800 In H2O 800 In H2O 800 InH2O

Performance Characteristics for: 1 MBAR-D-4V


Parameter, NOTE 1 Operating Range, differential pressure Output Span, NOTE 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (5C-50C), NOTE 2 Offset Warm-up Shift, NOTE 3 Offset Position Sensitivity (1g) Offset Long Term Drift (one year) Linearity, hysteresis error, NOTE 4 Span Shift (5C-50C), NOTE 2 20 40 20 0.05 0.25 4 1.80 2.00 Minimum Nominal 1.0 2.0 2.25 2.20 2.50 120 Maximum Units mbar V V mV mV mV mV %FSS %FSS

DS-0024 Rev B

Amplified Low Pressure Sensors

Performance Characteristics for 1 INCH-D-4V


Parameter, note 1 Operating Range, differential pressure Output Span, note 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (5C-50C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (5C-50C), note 2 10 5 10 0.05 0.25 2 1.90 2.15 Minimum Nominal 1.0 2.0 2.25 2.10 2.35 60 Maximum Units inH2O V V mV mV mV mV %FSS

Performance Characteristics for 1 INCH-G-4V


Parameter, note 1 Operating Range, gage pressure Output Span, note 5 Offset Voltage @ zero pressure Offset Temperature Shift (5C-50C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (5C-50C), note 2 10 15 10 0.05 0.25 2 3.90 0.15 Minimum Nominal 1.0 4.0 0.25 4.10 0.35 60 Maximum Units inH2O V V mV mV mV mV %FSS %FSS f 408 225 2079 a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314 e www.allsensors.com

Performance Characteristics for 2.5 INCH-D-4V


Parameter, note 1 Operating Range, differential pressure Output Span, note 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (5C-50C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (5C-50C), note 2 5 5 5 0.05 0.25 1 1.90 2.15 Minimum Nominal 2.5 2.0 2.25 2.10 2.35 40 Maximum Units inH2O V V V mV mV mV %FSS %FSS

All Sensors

DS-0024 Rev B

all sensors

%FSS

Performance Characteristics for 5 INCH-D-4V


Parameter, note 1 Operating Range, differential pressure Output Span, note 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (5C-50C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (5C-50C), note 2 5 5 5 0.05 0.25 1 1.90 2.15 Minimum Nominal 5.0 2.0 2.25 2.10 2.35 40 Maximum Units inH2O V V mV mV mV mV %FSS %FSS

Performance Characteristics for: 5 INCH-G-4V


Parameter, NOTE 1 Operating Range, gage pressure Output Span, NOTE 5 Offset Voltage @ zero pressure Offset Temperature Shift (5C-50C), NOTE 2 Offset Warm-up Shift, NOTE 3 Offset Position Sensitivity (1g) Offset Long Term Drift (one year) Linearity, hysteresis error, NOTE 4 Span Shift (5C-50C), NOTE 2 5 5 5 0.05 0.25 1 3.90 0.15 Minimum Nominal 5.0 4.0 0.25 4.10 0.35 40 Maximum Units inH2O V V mV mV mV mV %FSS %FSS

Performance Characteristics for: 10 INCH-D-4V


Parameter, NOTE 1 Operating Range, differential pressure Output Span, NOTE 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (5C-50C), NOTE 2 Offset Warm-up Shift, NOTE 3 Offset Position Sensitivity (1g) Offset Long Term Drift (one year) Linearity, hysteresis error, NOTE 4 Span Shift (5C-50C), NOTE 2 5 5 5 0.05 0.25 1 1.90 2.15 Minimum Nominal 10.0 2.0 2.25 2.10 2.35 20 Maximum Units inH2O V V mV mV mV mV %FSS %FSS

DS-0024 Rev B

Amplified Low Pressure Sensors

Performance Characteristics for: 10 INCH-G-4V


Parameter, NOTE 1 Operating Range, gage pressure Output Span, NOTE 5 Offset Voltage @ zero pressure Offset Temperature Shift (5C-50C), NOTE 2 Offset Warm-up Shift, NOTE 3 Offset Position Sensitivity (1g) Offset Long Term Drift (one year) Linearity, hysteresis error, NOTE 4 Span Shift (5C-50C), NOTE 2 5 5 5 0.05 0.25 1 3.90 0.15 Minimum Nominal 10.0 4.0 0.25 4.10 0.35 20 Maximum Units inH2O V V mV mV mV mV %FSS

Performance Characteristics for 20 INCH-D-4V


Parameter, note 1 Operating Range, differential pressure Output Span, note 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (5C-50C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (5C-50C), note 2 5 5 5 0.05 0.25 1 1.90 2.15 Minimum Nominal 20.0 2.0 2.25 2.10 2.35 20 Maximum Units inH2O V V mV mV mV mV %FSS %FSS f 408 225 2079 a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314 e www.allsensors.com

Performance Characteristics for 20 INCH-G-4V


Parameter, note 1 Operating Range, gage pressure Output Span, note 5 Offset Voltage @ zero pressure Offset Temperature Shift (5C-50C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (5C-50C), note 2 5 5 5 0.05 0.25 1 3.90 0.15 Minimum Nominal 20.0 4.0 0.25 4.1 0.35 20 Maximum Units inH2O V V mV mV mV mV %FSS %FSS

All Sensors

DS-0024 Rev B

all sensors

%FSS

Performance Characteristics for 30 INCH-D-4V


Parameter, note 1 Operating Range, differential pressure Output Span, note 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (5C-50C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (5C-50C), note 2 5 5 5 0.05 0.25 1 1.90 2.15 Minimum Nominal 30.0 2.0 2.25 2.10 2.35 20 Maximum Units inH2O V V mV mV mV mV %FSS %FSS

Performance Characteristics for 30 INCH-G-4V


Parameter, NOTE 1 Operating Range, gage pressure Output Span, NOTE 5 Offset Voltage @ zero pressure Offset Temperature Shift (5C-50C), NOTE 2 Offset Warm-up Shift, NOTE 3 Offset Position Sensitivity (1g) Offset Long Term Drift (one year) Linearity, hysteresis error, NOTE 4 Span Shift (5C-50C), NOTE 2 5 5 5 0.05 0.25 1 3.9 0.15 Minimum Nominal 30.0 4.0 0.25 4.1 0.35 20 Maximum Units inH2O V V V mV mV mV %FSS %FSS

Performance Characteristics for 60 INCH-G-4V


Parameter, NOTE 1 Operating Range, gage pressure Output Span, NOTE 5 Offset Voltage @ zero pressure Offset Temperature Shift (5C-50C), NOTE 2 Offset Warm-up Shift, NOTE 3 Offset Position Sensitivity (1g) Offset Long Term Drift (one year) Linearity, hysteresis error, NOTE 4 Span Shift (5C-50C), NOTE 2 5 5 5 0.05 0.25 1 3.9 0.15 Minimum Nominal 60.0 4.0 0.25 4.1 0.35 20 Maximum Units inH2O V V V mV mV mV %FSS %FSS

Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less than 500 useconds.
Specification Notes NOTE 1: ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED. PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO PORT B. NOTE 2: SHIFT IS RELATIVE TO 25C. NOTE 3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE. NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT. NOTE 5: THE SPAN IS THE ALGEBRAIC DIFFERENCE BETWEEN FULL SCALE OUTPUT VOLTAGE AND THE OFFSET VOLTAGE.
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

DS-0024 Rev B

Amplified Low Pressure Sensors