Overview
Common Channel Signaling System No. 7 (i.e., SS7 or C7) is a global standard for telecommunications defined by the International Telecommunication Union (ITU) Telecommunication Standardization Sector (ITU-T). The standard defines the procedures and protocol by which network elements in the public switched telephone network (PSTN) exchange information over a digital signaling network to effect wireless (cellular) and wireline call setup, routing and control. The ITU definition of SS7 allows for national variants such as the American National Standards Institute (ANSI) and Bell Communications Research (Telcordia Technologies) standards used in North America and the European Telecommunications Standards Institute (ETSI) standard used in Europe. The SS7 network and protocol are used for:
basic call setup, management, and tear down wireless services such as personal communications services (PCS), wireless roaming, and mobile subscriber authentication local number portability (LNP) toll-free (800/888) and toll (900) wireline services enhanced call features such as call forwarding, calling party name/number display, and three-way calling efficient and secure worldwide telecommunications
Signaling Links
SS7 messages are exchanged between network elements over 56 or 64 kilobit per second (kbps) bidirectional channels called signaling links. Signaling occurs out-of-band on dedicated channels rather than in-band on voice channels. Compared to in-band signaling, out-of-band signaling provides:
faster call setup times (compared to in-band signaling using multi-frequency (MF) signaling tones) more efficient use of voice circuits support for Intelligent Network (IN) services which require signaling to network elements without voice trunks (e.g., database systems) improved control over fraudulent network usage
Signaling Points
Each signaling point in the SS7 network is uniquely identified by a numeric point code. Point codes are carried in signaling messages exchanged between signaling points to identify the source and destination of each message. Each signaling point uses a routing table to select the appropriate signaling path for each message. There are three kinds of signaling points in the SS7 network (Fig. 1):
SSP (Service Switching Point) STP (Signal Transfer Point) SCP (Service Control Point)
Ing. Jos Carlos Benitez P. Universidad Nacional de Ingeniera Curso: RDSI (IT526M - FIEE)
jcbenitezp@yahoo.es
Ing. Jos Carlos Benitez P. Universidad Nacional de Ingeniera Curso: RDSI (IT526M - FIEE)
jcbenitezp@yahoo.es
A Link:
An "A" (access) link connects a signaling end point (e.g., an SCP or SSP) to an STP. Only messages originating from or destined to the signaling end point are transmitted on an "A" link. A "B" (bridge) link connects an STP to another STP. Typically, a quad of "B" links interconnect peer (or primary) STPs (e.g., the STPs from one network to the STPs of another network). The distinction between a "B" link and a "D" link is rather arbitrary. For this reason, such links may be referred to as "B/D" links. A "C" (cross) link connects STPs performing identical functions into a mated pair. A "C" link is used only when an STP has no other route available to a destination signaling point due to link failure(s). Note that SCPs may also be deployed in pairs to improve reliability; unlike STPs, however, mated SCPs are not interconnected by signaling links. A "D" (diagonal) link connects a secondary (e.g., local or regional) STP pair to a primary (e.g., inter-network gateway) STP pair in a quad-link configuration. Secondary STPs within the same network are connected via a quad of "D" links. The distinction between a "B" link and a "D" link is rather arbitrary. For this reason, such links may be referred to as "B/D" links. An "E" (extended) link connects an SSP to an alternate STP. "E" links provide an alternate signaling path if an SSP's "home" STP cannot be reached via an "A" link. "E" links are not usually provisioned unless the benefit of a marginally higher degree of reliability justifies the added expense. An "F" (fully associated) link connects two signaling end points (i.e., SSPs and SCPs). "F" links are not usually used in networks with STPs. In networks without STPs, "F" links directly connect signaling points.
B Link:
C Link:
D Link:
E Link:
F Link:
Ing. Jos Carlos Benitez P. Universidad Nacional de Ingeniera Curso: RDSI (IT526M - FIEE)
jcbenitezp@yahoo.es
Figure 3. The OSI Reference Model and the SS7 Protocol Stack
subsystem number. A subsystem number uniquely identifies an application at the destination signaling point. SCCP is used as the transport layer for TCAP-based services.
MTP Level 1
The lowest level, MTP Level 1, is equivalent to the OSI Physical Layer. MTP Level 1 defines the physical, electrical, and functional characteristics of the digital signaling link. Physical interfaces defined include E-1 (2048 kb/s; 32 64 kb/s channels), DS-1 (1544 kb/s; 24 64 kp/s channels), V.35 (64 kb/s), DS-0 (64 kb/s), and DS-0A (56 kb/s).
MTP Level 2
MTP Level 2 ensures accurate end-to-end transmission of a message cross a signaling link. Level 2 implements flow control, message sequence validation, and error checking. When an error occurs on a signaling link, the message (or set of messages) is retransmitted. MTP Level 2 is equivalent to the OSI Data Link Layer. An SS7 message is called a signal unit (SU). There are three kinds of signal units: Fill-In Signal Units (FISUs), Link Status Signal Units (LSSUs), and Message Signal Units (MSUs) (Fig. 4).
Ing. Jos Carlos Benitez P. Universidad Nacional de Ingeniera Curso: RDSI (IT526M - FIEE)
jcbenitezp@yahoo.es
Figure 4. SS7 Signal Units Fill-In Signal Units (FISUs) are transmitted continuously on a signaling link in both directions unless other signal units (MSUs or LSSUs) are present. FISUs carry basic level 2 information only (e.g., acknowledgment of signal unit receipt by a remote signaling point). Because a CRC checksum is calculated for each FISU, signaling link quality is checked continuously by both signaling points at either end of the link. (Note: In the ITU-T Japan variant, signaling link quality is checked by the continuous transmission of flag octets (8-bit bytes) rather than FISUs; FISUs are sent only at predefined timer intervals (e.g., once every 150 milliseconds). Link Status Signal Units (LSSUs) carry one or two octets (8-bit bytes) of link status information between signaling points at either end of a link. The link status is used to control link alignment and to indicate the status of a signaling point (e.g., local processor outage) to the remote signaling point. Message Signal Units (MSUs) carry all call control, database query and response, network management, and network maintenance data in the signaling information field (SIF). MSUs have a routing label which allows an originating signaling point to send information to a destination signaling point across the network. The value of the LI (Length Indicator) field determines the signal unit type:
LI Value 0 1..2 3..63 Signal Unit Type Fill-In Signal Unit (FISU) Link Status Signal Unit (LSSU) Message Signal Unit (MSU)
Figure 5. Message Type Length Indicator Value(s) The 6-bit LI can store values between zero and 63. If the number of octets which follow the LI and precede the CRC is less than 63, the LI contains this number. Otherwise, the LI is set to 63. An LI of 63 indicates that the message length is equal to or greater than 63 octets (up to a maximum of 273 octets). The maximum length of a signal unit is 279 octets: 273 octets (data) + 1 octet (flag) + 1 octet (BSN + BIB) + 1 octet (FSN + FIB) + 1 octet (LI + 2 bits spare) + 2 octets (CRC). Flag The flag indicates the beginning of a new signal unit and implies the end of the previous signal unit (if any). The binary value of the flag is 0111 1110. Before transmitting a signal unit, MTP Level 2 removes "false flags" by adding a zero-bit after any sequence of five one-bits. Upon receiving a signal unit and stripping the flag, MTP
Ing. Jos Carlos Benitez P. Universidad Nacional de Ingeniera Curso: RDSI (IT526M - FIEE) Learning Docs Material de Enseanza jcbenitezp@yahoo.es
Level 2 removes any zero-bit following a sequence of five one-bits to restore the original contents of the message. Duplicate flags are removed between signal units. BSN (Backward Sequence Number) The BSN is used to acknowledge the receipt of signal units by the remote signaling point. The BSN contains the sequence number of the signal unit being acknowledged. (See description under FIB below.) BIB (Backward Indicator Bit) The BIB indicates a negative acknowledgment by the remote signaling point when toggled. (See description under FIB below.) FSN (Forward Sequence Number) The FSN contains the sequence number of the signal unit. (See description under FIB below.) FIB (Forward Indicator Bit) The FIB is used in error recovery like the BIB. When a signal unit is ready for transmission, the signaling point increments the FSN (forward sequence number) by 1 (FSN = 0..127). The CRC (cyclic redundancy check) checksum value is calculated and appended to the forward message. Upon receiving the message, the remote signaling point checks the CRC and copies the value of the FSN into the BSN of the next available message scheduled for transmission back to the initiating signaling point. If the CRC is correct, the backward message is transmitted. If the CRC is incorrect, the remote signaling point indicates negative acknowledgment by toggling the BIB prior to sending the backward message. When the originating signaling point receives a negative acknowledgment, it retransmits all forward messages, beginning with the corrupted message, with the FIB toggled. Because the 7-bit FSN can store values between zero and 127, a signaling point can send up to 128 signal units before requiring acknowledgment from the remote signaling point. The BSN indicates the last in-sequence signal unit received correctly by the remote signaling point. The BSN acknowledges all previously received signal units as well. For example, if a signaling point receives a signal unit with BSN = 5 followed by another with BSN = 10 (and the BIB is not toggled), the latter BSN implies successful receipt of signal units 6 through 9 as well. SIO (Service Information Octet) The SIO field in an MSU contains the 4-bit subservice field followed by the 4-bit service indicator. FISUs and LSSUs do not contain an SIO. The subservice field contains the network indicator (e.g., national or international) and the message priority (0..3 with 3 being the highest priority). Message priority is considered only under congestion conditions, not to control the order in which messages are transmitted. Low priority messages may be discarded during periods of congestion. Signaling link test messages receive a higher priority than call setup messages. The service indicator specifies the MTP user (Fig. 6), thereby allowing the decoding of the information contained in the SIF.
Service Indicator 0 1 2 3 4 5 6 7 MTP User Signaling Network Management Message (SNM) Maintenance Regular Message (MTN) Maintenance Special Message (MTNS) Signaling Connection Control Part (SCCP) Telephone User Part (TUP) ISDN User Part (ISUP) Data User Part (call and circuit-related messages) Data User Part (facility registration/cancellation messages)
Figure 6. Service Indicator Values SIF (Signaling Information Field) The SIF in an MSU contains the routing label and signaling information (e.g., SCCP, TCAP, and ISUP message data). LSSUs and FISUs contain neither a routing label nor an SIO as they are sent between two directly
Ing. Jos Carlos Benitez P. Universidad Nacional de Ingeniera Curso: RDSI (IT526M - FIEE) Learning Docs Material de Enseanza jcbenitezp@yahoo.es
connected signaling points. For more information about routing labels, refer to the description of MTP Level 3 below. CRC (Cyclic Redundancy Check) The CRC value is used to detect and correct data transmission errors. For more information, see the description for BIB above.
MTP Level 3
MTP Level 3 provides message routing between signaling points in the SS7 network. MTP Level 3 is equivalent in function to the OSI Network Layer. MTP Level 3 routes messages based on the routing label in the signaling information field (SIF) of message signal units. The routing label is comprised of the destination point code (DPC), originating point code (OPC), and signaling link selection (SLS) field. Points codes are numeric addresses which uniquely identify each signaling point in the SS7 network. When the destination point code in a message indicates the receiving signaling point, the message is distributed to the appropriate user part (e.g., ISUP or SCCP) indicated by the service indicator in the SIO. Messages destined for other signaling points are transferred provided that the receiving signaling point has message transfer capabilities (like an STP). The selection of outgoing link is based on information in the DPC and SLS. An ANSI routing label uses 7 octets; an ITU-T routing label uses 4 octets (Fig. 7).
Figure 7. ANSI vs. ITU-T SIO and SIF ANSI point codes use 24-bits (three octets); ITU-T point codes typically use 14-bits. For this reason, signaling information exchanged between ANSI and ITU-T networks must be routed through a gateway STP, protocol converter, or other signaling point which has both an ANSI and an ITU-T point code. (Note: China uses 24-bit ITU-T point codes which are incompatible with both ANSI and other ITU-T networks). Interaction between ANSI and ITU-T networks is further complicated by different implementations of higher level protocols and procedures. An ANSI point code consists of network, cluster, and member octets (e.g., 245-16-0). An octet is an 8-bit byte which can contain any value between zero and 255. Telcos with large networks have unique network identifiers while smaller operators are assigned a unique cluster number within networks 1 through 4 (e.g., 1-123-9). Network number 0 is not used; network number 255 is reserved for future use.
Ing. Jos Carlos Benitez P. Universidad Nacional de Ingeniera Curso: RDSI (IT526M - FIEE) Learning Docs Material de Enseanza jcbenitezp@yahoo.es
ITU-T point codes are pure binary numbers which may be stated in terms of zone, area/network, and signaling point identification numbers. For example, the point code 5557 (decimal) may be stated as 2-182-5 (binary 010 10110110 101). Signaling Link Selection (SLS) The selection of outgoing link is based on information in the DPC and Signaling Link Selection field. The SLS is used to:
Ensure message sequencing. Any two messages sent with the same SLS will always arrive at the destination in the same order in which they were originally sent. Allow equal load sharing of traffic among all available links. In theory, if a user part sends messages at regular intervals and assigns the SLS values in a round-robin fashion, the traffic level should be equal among all links (within the combined linkset) to that destination.
In ANSI networks, the size of the SLS field was originally 5 bits (32 values). In configurations with two links in each linkset of a combined linkset (totaling 4 links), 8 SLS values were assigned to each link to allow an equal balance of traffic. A problem arose when growing networks provisioned linksets beyond 4 links. With a 5 bit SLS, a configuration with 5 links in each linkset of a combined linkset (totaling 10 links) results in an uneven assignment of 3 SLS values for 8 links and 4 SLS values for the remaining 2 links. To eliminate this problem, both ANSI and Bellcore moved to adopt an 8-bit SLS (256 values) to provide better loadsharing across signaling links. In ITU-T implementations, the SLS is interpreted as the signaling link code in MTP messages. In ITU-T Telephone User Part message, a portion of the circuit identification code is stored in the SLS field. MTP Level 3 re-routes traffic away from failed links and signaling points and controls traffic when congestion occurs. However, a detailed discussion of this topic is outside the scope of this tutorial. MTP Levels 2 and 1 can be replaced by ATM (Asynchronous Transfer Mode), a simple broadband protocol which uses fixed-length 53 octet cells. MTP Level 3 interfaces to ATM using the Signaling ATM Adaptation Layer (SAAL). This interface is currently an area of ongoing study.
When a call is placed to an out-of-switch number, the originating SSP transmits an ISUP initial address message (IAM) to reserve an idle trunk circuit from the originating switch to the destination switch (1a). The IAM includes the originating point code, destination point code, circuit identification code (circuit "5" in Fig. 8), dialed digits and, optionally, the calling party number and name. In the example below, the IAM is routed via the home STP of the originating switch to the destination switch (1b). Note that the same signaling link(s) are used for the duration of the call unless a link failure condition forces a switch to use an alternate signaling link.
Ing. Jos Carlos Benitez P. Universidad Nacional de Ingeniera Curso: RDSI (IT526M - FIEE)
jcbenitezp@yahoo.es
The destination switch examines the dialed number, determines that it serves the called party, and that the line is available for ringing. The destination switch rings the called party line and transmits an ISUP address complete message (ACM) to the originating switch (2a) (via its home STP) to indicate that the remote end of the trunk circuit has been reserved. The STP routes the ACM to the originating switch (2b), then the terminating switch provides power ringing to the called party and audible ringing tone to the calling party. In the example shown above, the originating and destination switches are directly connected with trunks. If the originating and destination switches are not directly connected with trunks, the originating switch transmits an IAM to reserve a trunk circuit to an intermediate switch. The intermediate switch sends an ACM to acknowledge the circuit reservation request and then transmits an IAM to reserve a trunk circuit to another switch. This processes continues until all trunks required to complete the voice circuit from the originating switch to the destination switch are reserved.
When the called party picks up the phone, the destination switch terminates the ringing tone and transmits an ISUP answer message (ANM) to the originating switch via its home STP (3a). The STP routes the ANM to the originating switch (3b) which verifies that the calling party's line is connected to the reserved trunk and, if so, initiates billing. If the calling party hangs-up first, the originating switch sends an ISUP release message (REL) to release the trunk circuit between the switches (4a). The STP routes the REL to the destination switch (4b). If the called party hangs up first, or if the line is busy, the destination switch sends an REL to the originating switch indicating the release cause (e.g., normal release or busy). Upon receiving the REL, the destination switch disconnects the trunk from the called party's line, sets the trunk state to idle, and transmits an ISUP release complete message (RLC) to the originating switch (5a) to acknowledge the release of the remote end of the trunk circuit. When the originating switch receives (or generates) the RLC (5b), it terminates the billing cycle and sets the trunk state to idle in preparation for the next call.
ISUP messages may also be transmitted during the connection phase of the call (i.e., between the ISUP Answer (ANM) and Release (REL) messages.
Ing. Jos Carlos Benitez P. Universidad Nacional de Ingeniera Curso: RDSI (IT526M - FIEE)
jcbenitezp@yahoo.es
Figure 9. ISUP Message Format Each ISUP message contains a mandatory fixed part containing mandatory fixed-length parameters. Sometimes the mandatory fixed part is comprised only of the message type field. The mandatory fixed part may be followed by the mandatory variable part and/or the optional part. The mandatory variable part contains mandatory variable-length parameters. The optional part contains optional parameters which are identified by a one-octet parameter code followed by a length indicator ("octets to follow") field. Optional parameters may occur in any order. If optional parameters are included, the end of the optional parameters is indicated by an octet containing all zeros.
Ing. Jos Carlos Benitez P. Universidad Nacional de Ingeniera Curso: RDSI (IT526M - FIEE)
jcbenitezp@yahoo.es
Figure 10. ANSI and ITU-T Initial Address Message (IAM) Format
Ing. Jos Carlos Benitez P. Universidad Nacional de Ingeniera Curso: RDSI (IT526M - FIEE)
jcbenitezp@yahoo.es
Figure 11. ANSI and ITU-T Address Complete Message (ACM) Format When the called party answers, the destination switch terminates power ringing of the called line, removes audible ringing tone from the calling line and sends an Answer Message (ANM) to the originating switch. The originating switch initiates billing after verifying that the calling party's line is connected to the reserved trunk.
Release Message
A Release Message (REL) is sent in either direction indicating that the circuit is being released due to the cause indicator specified. An REL is sent when either the calling or called party "hangs up" the call (cause = 16). An REL is also sent in the backward direction if the called party line is busy (cause = 17).
Ing. Jos Carlos Benitez P. Universidad Nacional de Ingeniera Curso: RDSI (IT526M - FIEE)
jcbenitezp@yahoo.es
Figure 14. ANSI and ITU-T Release Complete (RLC) Message Format
local number portability, wireless roaming, and personal communications services (PCS). Global Title Translation SCCP also provides the means by which an STP can perform global title translation (GTT), a procedure by which the destination signaling point and subsystem number (SSN) is determined from digits (i.e., the global title) present in the signaling message. The global title digits may be any sequence of digits (e.g., the dialed 800/888 number, calling card number, or mobile subscriber identification number) pertinent to the service requested. Because an STP provides global title translation, originating signaling points do not need to know the destination point code or subsystem number of the associated service. Only the STPs need to maintain a database of destination point codes and subsystem numbers associated with specific services and possible destinations.
Figure 15. SCCP Message Format Each SCCP message contains a mandatory fixed part (mandatory fixed-length parameters), mandatory variable part (mandatory variable-length parameters), and an optional part which may contain fixed-length and variable-length fields. Each optional part parameter is identified by a one-octet parameter code followed by a length indicator ("octets to follow") field. Optional parameters may occur in any order. If optional parameters are included, the end of the optional parameters is indicated by an octet containing all zeros.
query an SCP to determine the routing number(s) associated with a dialed 800, 888, or 900 number. The SCP uses TCAP to return a response containing the routing number(s) (or an error or reject component) back to the SSP. Calling card calls are also validated using TCAP query and response messages. When a mobile subscriber roams into a new mobile switching center (MSC) area, the integrated visitor location register requests service profile information from the subscriber's home location register (HLR) using mobile application part (MAP) information carried within TCAP messages. TCAP messages are contained within the SCCP portion of an MSU. A TCAP message is comprised of a transaction portion and a component portion.
Transaction Portion
The transaction portion contains the package type identifier. There are seven package types:
Unidirectional: Transfers component(s) in one direction only (no reply expected). Query with Permission: Initiates a TCAP transaction (e.g., a 1-800 query). The destination node may end the transaction. Query without Permission: Initiates a TCAP transaction. The destination node may not end the transaction. Response: Ends the TCAP transaction. A response to an 1-800 query with permission may contain the routing number(s) associated with the 800 number. Conversation with Permission: Continues a TCAP transaction. The destination node may end the transaction. Conversation without Permission: Continues a TCAP transaction. The destination node may not end the transaction. Abort: Terminates a transaction due to an abnormal situation.
The transaction portion also contains the Originating Transaction ID and Responding Transaction ID fields which associate the TCAP transaction with a specific application at the originating and destination signaling points respectively.
Component Portion
The component portion contains components. There are six kinds of components:
Invoke (Last): Invokes an operation. For example, a Query with Permission transaction may include an Invoke (Last) component to request SCP translation of a dialed 800 number. The component is the "last" component in the query. Invoke (Not Last): Similar to the Invoke (Last) component except that the component is followed by one or more components. Return Result (Last): Returns the result of an invoked operation. The component is the "last" component in the response. Return Result (Not Last): Similar to the Return Result (Last) component except that the component is followed by one or more components. Return Error: Reports the unsuccessful completion of an invoked operation. Reject: Indicates that an incorrect package type or component was received.
Components include parameters which contain application-specific data carried unexamined by TCAP.
SS7 over IP
Telephone companies offload voice calls from public switched telephone networks (PSTNs) to voice-over-Internet Protocol (VoIP) networks because it is cheaper to carry voice traffic over Internet Protocol (IP) networks than over switched circuit networks. In the future, IP telephony networks are expected to enable innovative new multimedia services while working seamlessly with legacy telephone networks. Ing. Jos Carlos Benitez P. Universidad Nacional de Ingeniera Curso: RDSI (IT526M - FIEE) Learning Docs Material de Enseanza jcbenitezp@yahoo.es
A VoIP network carries voice traffic cheaper than a switched circuit telephone network because IP telephony networks make better use of available bandwidth. In a public switched telephone network, for example, a dedicated 64 kilobits per second (kbps) end-to-end circuit is allocated for each call. In a VoIP network, digitized voice data is highly compressed and carried in packets over IP networks. Using the same bandwidth, a VoIP network can carry many times the number of voice calls as a switched circuit network with better voice quality. The savings realized in using VoIP networks are often passed onto users in the form of lower costs.
International Telecommunication Union (ITU) American National Standards Institute (ANSI) Telcordia Technologies (formerly Bellcore) European Telecommunications Standards Institute (ETSI)
Bibliography
The following table lists several important SS7 standards documents which were used in the preparation of this tutorial:
SS7 Level
MTP Level 2 MTP Level 3 SCCP TUP ISUP TCAP
ITU Standard
ITU Q.701 - Q.703, 1992 ITU Q.704 - Q.707, 1992 ITU Q.711 - Q.714, 1992 CCITT Q.721 - Q.724, 1988 ITU Q.761 - Q.764, 1992 ITU Q.771 - Q.775, 1992
ANSI Standard
ANSI T1.111.2-.3, 1992 ANSI T1.111.4-.7, 1992 ANSI T1.112, 1992 N/A ANSI T1.113, 1992 ANSI T1.114, 1992
Ing. Jos Carlos Benitez P. Universidad Nacional de Ingeniera Curso: RDSI (IT526M - FIEE)
jcbenitezp@yahoo.es