Renishaws 40 m RGH41 series readheads offer all the benefits of the established 20 m RG2 linear encoder system, such as reflective tape scale, patented filtering optics, set-up LED, good dirt immunity and high speed.
These compact readheads with integral interpolation provide an increased range of resolutions to match the demands of a wide range of applications, whilst their high speed enables an increase in the productivity of the end-users system. The 40 m RGH41 increases the already generous set-up tolerances of the RG2, whilst maintaining Renishaws famous contamination immunity. For added flexibility, dual limit switch sensing is included as standard to enable dedicated signals for each end-of-axis indication, along with a repeatable reference or datum mark.
These benefits give the RGH41 greater flexibility complementing the breadth of applications in which the RG2 is already used, from co-ordinate measuring and layout machines to electronics assembly and test, linear motors and a host of custom linear motor solutions. Digital range RGH41T - 10 m resolution RGH41D - 5 m resolution RGH41G - 2 m resolution RGH41X - 1 m resolution RGH41N - 0.4 m resolution RGH41W - 0.2 m resolution RGH41Y - 0.1 m resolution RGH41H - 50 nm resolution Analogue range RGH41B - 1 Vpp differential (single limit) RGH41A - 1 Vpp differential (dual limit)
Non-contact open optical system Large installation tolerances High speed operation up to 15 m/s Industry standard digital and analogue output options Resolutions from 10m to 50 nm Integral reference and dual limit sensors Integral set-up LED Uses Renishaw RGS40-S self-adhesive scale
14
14.5
13
27
RGS40 scale
10.5
3* 8.6 0.13 (Roll tol. 1) A-9531-0251 Q limit switch actuator Mount dimple up
A-9531-0251 P limit switch actuator Mount dimple to substrate (size as Q actuator) Arrow indicates forward direction of readhead relative to scale 44 38 3 A
Detail A
Readhead Scale surface (Pitch tol. 1) 0.8 Readhead to scale clearance Arrow indicates optical and reference mark centre line 2* Rideheight 0.8 0.15
4.7 max.
11.6* 5*
2.2*
Output specifications
Digital output signals - RGH41T, D, G, X, N, W, Y, H
Form - square wave differential line driver to EIA RS422A (except limit switch P, Q, Alarm E- and external set-up signal X) Incremental 2 channels A and B in quadrature (90 phase shifted)
Signal period P Model RGH41T Resolution S RGH41D RGH41G RGH41X RGH41N RGH40W A B RGH40Y RGH40H P (m) S (m) 40 20 8 4 1.6 0.8 0.4 0.2 10 5 2 1 0.4 0.2 0.1 0.05
Alarm single limit readheads - differential line driven output dual limit readheads - single-ended line driven output 20 ms minimum
For RGH41T, G, X alarm asserted for signal amplitude <15 %. Either asynchronous pulse E as shown (options 03/05) or line driver channels 3-state (options 04-06). For RGH41N, W, Y, H - alarm Easserted when: - Signal amplitude >150% - Readhead exceeds specified maximum speed Also, outputs are 3-stated at signal amplitude <15%
E
Inverse signal not shown for clarity E- only on dual limit readheads (option 05/06)
Reference
Synchronised pulse Z, duration as resolution S. Repeatability of position (uni-directional) maintained within 20 C from temperature at time of phasing and for speeds <0.5 m/s. For RGH40W, Y, H only Z pulse re-synchronised at power-up with any one of the quadrature states (00, 01, 11, 10). Inverse signal not shown for clarity
External set-up
5 (nom) voltage at X 0 0 50% signal level 70% 100%
Between 50% and 70% signal level , X is a duty cycle, 40 m duration. Time spent at 5 V increases with signal level. At >70% signal level X is nominal 5V.
Limit open collector output Single limit (option 03/04) Dual limit (option 05/06) Length of actuating magnet Q Repeatability < 0.1 mm P, Q Length of actuating magnet Repeatability < 0.1 mm Termination 5 V to 25 V R* P, Q
Recommended signal termination Readhead A B Z E+ Cable Z0 = 120R A B Z E5V 1k # 120R Customer electronics
1k
0V Standard RS422A line receiver circuitry. # Only required on alarm channel E for fail safe operation and to ensure alarm signal is asserted at low signal amplitude on RGH41N, W, Y, H when output is 3-stated
Asynchronous pulse P, Q. Actuation device A-9531-0251, A-9531-2052, A-9531-2054. *Select R so that the maximum current does not exceed 20 mA. Alternatively, a suitable relay or opto-isolator may be used.
Reference
(V0+) - (V0-)
-18 0
108
Differential pulse V0 -18 to 108 . Duration 126 (electrical). Repeatability of position (uni-directional) maintained within 20C from temperature at time of phasing, and for speeds <0.5 m/s. Actuation device A-9531-0250. V0 V1 V2+ 120R V0 V1 V2-
Asynchronous pulse P, Q. Actuation device A-9531-0251, A-9531-2052, A-9531-2054. *Select R so that the maximum current does not exceed 20 mA. Alternatively, a suitable relay or opto-isolator may be used. External set-up Between 50% and 70% signal level , X is a duty cycle, 20 m duration. Time spent at 5 V increases with signal level. At >70% signal level X is nominal 5V.
Renishaw plc New Mills, Wotton-under-Edge, Gloucestershire GL12 8JR United Kingdom
Digital readheads
Head type T D G X N, W, Y, H option 61 62 63 N 3.0 2.6 1.3 Maximum speed (m/s) Minimum recommended counter clock frequency (MHz)
Encoder velocity (m/s) Resolution (m)
15
12 10 6 W 2.5 1.3 0.7
x4 safety factor
10 Frequency (kHz) 2
100 4 8 16
Speed (m/s)
20 10 5
Power supply 5 V 5% Ripple Temperature Humidity Sealing Acceleration Shock (non-operating) Vibration (operating) Mass EMC compliance (system) Cable Connector options
120 mA (typical), 175 mA (RGH41N, W, Y, H) NOTE: For digital outputs, current consumption figures refer to unterminated readheads / interfaces. A further 25 mA per channel pair (eg A+, A-) will be drawn when terminated with 120 . Renishaw encoder systems must be powered from a 5 V dc supply complying with the requirements for SELV of standard EN (IEC) 60950. <200 mVpp maximum @ frequency up to 500 kHz maximum Operating 0 C to +55 C
Storage 95% maximum relative humidity (non-condensing) Operating 80% maximum relative humidity (non-condensing) IP50 Operating 500 m/s 2 BS EN 60068-2-7:1993 (IEC 68-2-7:1983) 1000 m/s 2, 6 ms, sine BS EN 60068-2-27:1993 (IEC 68-2-27:1987) 100 m/s2 max @ 55 Hz to 2000 Hz BS EN 60068-2-6:1996 (IEC 68-2-6:1995) Readhead 50 g Cable 38 g/m
BS EN 61000 BS EN 55011 12 core, double-shielded, maximum outside diameter 4.7 mm Flex life >20 x 10 6 cycles at 50 mm bend radius Code - connector type D - 15 pin D type plug L - 15 pin D type plug V - 12 pin circular plug W - 12 pin circular coupling plug F - Flying lead X - 16 pin in line connector Application RGH41T, D, G, X, N, W, Y, H RGH41A, B RGH41B RGH41B All readheads All readheads