Nemo Handy-A 1.50 Manual
Nemo Handy-A 1.50 Manual
Nemo Handy-A 1.50 Manual
2013 by Anite Finland Ltd. All rights reserved. This manual, as well as the software described in it, is furnished under license and may only be used or copied in accordance with the terms of such license. The information in this manual is intended for informational use only and is subject to change without notice. Anite Finland Ltd assumes no responsibility or liability for any errors or inaccuracies that may appear in this user manual. Except as permitted by such license, no part of this publication may be reproduced or transmitted in any form or by any means, electronic, mechanical, recording, or otherwise, without the prior written permission of Anite Finland Ltd. Android is a trademark of Google Inc. CDMA 2000 is a registered trademark of the Telecommunications Industry Association (TIA -USA). The license management portion of this Licensed Technology is based on SentinelLM* 1989-2003 Rainbow Technologies, Inc. Any other trademarks or service marks contained herein are the property of their respective owners. All rights reserved.
C ON T E N T S
CONTENTS
QUICK GUIDE BEFORE YOU BEGIN
NOTES IMPORTANT End-User License Agreement Traffic Safety Operating Environment
8 9
9 10 10 10 10
12
12 13
INSTALLING NEMO HANDY-A FROM NEMO USER CLUB INSTALLING NEMO HANDY-A LICENSE CONNECTING AN EXTERNAL GPS 14 15
DURING MEASUREMENTS
MANUAL APPLICATION TESTING Manual Voice Call Testing Manual SMS Testing Manual HTTP Testing Manual YouTube Testing Manual Iperf Testing Manual FTP Testing Manual ICMP Ping SCRIPTED APPLICATION TESTING Creating Scripts Scripted Voice Calls Scripted FTP Transfer Scripted HTTP Transfer
16
16 16 17 19 20 22 22 24 25 28 32 32 33
N e mo Han d y-A U s e r Ma nu al
Scripted HTML Browsing Scripted ICMP Ping Scripted SMS Send Scripted Iperf TCP/UDP Scripted YouTube Testing Nested Script Wait AUTOMATED TESTING Automated Testing Settings Maintenance FTP
35 36 37 37 39 40 41 42 42 43 45
Scheduling Maintenance and Measurement Sessions Manually Manual Start and Stop 48 48
Access Point for Maintenance and Scripted Connections VOICE QUALITY TESTING POLQA NB/SWB Mode Selection Voice Quality Testing in Uplink+Downlink Mode Voice Quality Testing in Downlink Mode FORCING FEATURES System Lock Band Lock Preferred Channel Lock (UMTS) IP CAPTURE INDOOR MEASUREMENTS Importing Maps and Defining Map Settings Importing iBwave Maps Performing Indoor Measurements Route Plans OUTDOOR MEASUREMENTS 48 49 49 49 49 50 51 52 52 53 53 55 57 58 60
C ON T E N T S
63 66
Use Case 1 Outdoor Map with Route, BTS, and Notification Icons DEFINING ROUTE PARAMETERS FILE EXPLORER PLAYBACK 67 70 71
74
74 75 75 75 76 77 78 79 80 81 82 82 83 83 84 85 85 87 87 89 91 92
N e mo Han d y-A U s e r Ma nu al
GPRS View for GSM WCDMA VIEWS Summary View for WCDMA Cell Measurements View for WCDMA WCDMA View Throughput View for WCDMA HSPA View for WCDMA LTE VIEWS Summary View for LTE Cell Measurements View for LTE Link Adaptation View for LTE Throughput View for LTE CDMA/EVDO VIEWS Summary View for CDMA Cell Measurements View for CDMA Power Control View for CDMA/EVDO RX Power View for CDMA/EVDO
94 95 95 98 99 99 102 104 104 107 108 110 114 114 115 116 117
SETTINGS
GENERAL SETTINGS DISPLAY SETTINGS Notifications LOGGING SETTINGS Log File Splitting Defining Measurement Upload Configurations GPS SETTINGS INDOOR MAP SETTINGS OUTDOOR MAP SETTINGS BTS SETTINGS
118
118 119 121 124 124 127 131 132 133 135
C ON T E N T S
ENDING MEASUREMENTS
UPLOADING LOG FILES ON SERVER EXPORTING FILES MANUALLY
140
141 142 142
POST-PROCESSING MEASUREMENTS145
POST-PROCESSING WITH NEMO OUTDOOR POST-PROCESSING WITH NEMO ANALYZE 145 145
146
146 146 146
147
147 147 147 147
APPENDIX
END-USER LICENSE AGREEMENT
150
150
N e mo Han d y-A U s e r Ma nu al
QUICK GUIDE
This quick guide will explain briefly how to set up the Nemo Handy-A measurement system and how to start the actual measurements. Do not upgrade, root, or reflash your Nemo Handy measurement terminal firmware. Doing so will cause the terminal to permanently lose its measurement capability!
Using Nemo Handy 1. Select the Nemo Handy button from the All apps view by tapping Menu | All apps on your Nemo
Handy-A mobile. 2. If you want to use scripts, select Menu | Scripts. If there are no scripts created yet, select Menu | New script and add script commands by tapping Add at the bottom right corner on the screen. Otherwise, choose a script from the list and select Load & Run. 3. To start recording manually, select Menu | Start logging. Once the recording has started, the recording icon ( ) appears on the touchpad. 4. You can browse the different views by dragging your finger horizontally across the screen. If a view has several pages, you can move between the pages by dragging your finger vertically across the screen. To take screenshots of views, select Menu | Screenshot. 5. While Nemo Handy-A is logging, you can use the mobile normally for making calls, sending SMS messages, etc. Tap the Home button on the bottom left corner of the screen to switch between different applications or to make a call. 6. Stop the recording by selecting Menu | Stop logging. You are able to keep, rename or delete the resulting log file. 7. Export the measurement file for post-processing.
B E FOR E Y OU B E G IN
NOTES
When using the Nemo Handy-A test mobile for measurement use, the battery operation time is reduced from normal use. The best operation times will be achieved when the batteries are regularly charged and discharged as instructed in the mobile user manual. See also other instructions and hints from the mobile user manual regarding the battery use.
10
N e mo Han d y-A U s e r Ma nu al
Traffic Safety
Do not operate Nemo Handy-A and drive (or walk) at the same time. Remember, traffic safety comes first.
Operating Environment
Do not operate Nemo Handy-A without reading the User Manual, including its warnings, for the devices used by Nemo Handy-A. Always stop using Nemo Handy-A and switch off the Nemo Handy-A test device(s) when it is forbidden to use radio equipment or when it may cause interference or danger. Do not use the Nemo Handy-A test device(s) in a hospital. It may interfere with nearby electronic devices. Never use Nemo Handy-A in an aircraft. The use of mobiles in an aircraft may be dangerous. Observe restrictions on the use of radio equipment in gas stations, fuel depots, chemical plants, or sites where blasting operations are in progress.
SE T U P
11
x x x x x x x
x x x x x x x x x x x x x
x x x x x x x x x x x x x x x x x x x x x
1)
Includes voice calls, FTP/HTTP data transfers, HTML browsing, YouTube testing, SMS messaging, and ping.
12
N e mo Han d y-A U s e r Ma nu al
7. If you already have Nemo Handy-A installed on the mobile, the installer program will ask to replace the old version. Press OK. 8. Press Install to confirm the installation. 9. Installation is started and once it is finished, you can start using Nemo Handy-A.
SE T U P
13
3. Select All apps/Downloads and tap the setup package (.apk) after transfer is completed.
14
N e mo Han d y-A U s e r Ma nu al
7. If you already have a Nemo Handy-A license installed on the mobile, the installer program will ask to replace the old version. Press OK. 8. Press Install to confirm the installation. 9. Installation is started and once it is finished, you can start using Nemo Handy-A.
SE T U P
15
16
N e mo Han d y-A U s e r Ma nu al
DURING MEASUREMENTS
After you start logging with Nemo Handy-A (Menu | Start logging) you can use the mobile as any regular mobile. Nemo Handy-A runs in the background recording all measurement data. Tap the Home button on the bottom left corner of the phone to switch between different applications or to make a call. To return to Nemo Handy-A views from the Menu pop up views, tap the arrow button at the bottom of the phone. During measurements, calls and data transfers can be made and/or the phone can be left in an idle state, during which time measurements are carried out. Measurement results are stored into a file filename.nbl. You can view the measurement process in a number of views. You can browse the various views by swiping the touchpad with your finger. Note that the scales in the line graphs will change according to the selected parameter. The different views are described in detail in chapter Nemo Handy-A Views. You can add markers in the log file to mark points of interest during the measurement. To add a marker, tap on the toolbar to open the Tools view and select Add marker.
DU R IN G ME A SUR E ME N T S
17
Enter a phone number by tapping the Phone number field. Alternatively you can or select an existing contact from the address book by tapping the folder icon. Finally, tap Call.
When making a call attempt the call alerting icon ( the Tools button ( ) and select Hang up call.
18
N e mo Han d y-A U s e r Ma nu al
To manually test sending SMS messages, turn logging on by selecting Options | Start Logging, tap the Tools button and select Send SMS.
Select the Request delivery report option to receive a report about the message sending. Custom service center defines a service center, other than the default service center, used to send messages. If you leave this field empty, Nemo Handy will use the default service center. Destination defines the recipient mobile number. Tap the folder icon to select the recipient from address book.
DU R IN G ME A SUR E ME N T S
19
Message refers to the test SMS message sent. Type here the test message. Finally tap Send to send the test message.
Enter the HTTP URL, select the direction of the transfer (Download/Upload), enter data amount in kB (only in upload). Select the Download dynamic data from Nemo Server option to download automatically generated test data from Nemo Server. Finally, select Start to begin the HTTP transfer.
20
N e mo Han d y-A U s e r Ma nu al
Tap the Recent transfer button to access a list of previously used HTTP transfers. This way you can quickly define HTTP connection settings and the file used in the transfer.
If there are no previously used transfer settings, tap the Select host button. Select HTTP or HTTPS.
On the Select HTTP/S connection page, select one of the predefined HTTP/S connections and tap Select. To create a new connection, see chapter HTTP/HTTPS Connection Settings.
DU R IN G ME A SUR E ME N T S
21
Go to the YouTube view. Select one of the options to search for a video.
Select a video from the list and tap the still image to start playing the video.
The video plays in the YouTube view. With the controls you can pause the video and move back and forth in the video. On the screen are displayed some video streaming related parameters.
Init displays the video initialization time in seconds. min s / min s displays the current point and the duration of the video.
22
N e mo Han d y-A U s e r Ma nu al
Buffer is the percentage of the total video size that is currently buffered. Width defines the width of the video view in pixels. Height defines the height of the video view in pixels. Format displays the YouTube media encoding option that defines the size and encoding of the video (e.g. MPEG-4, H.264, or VP8). A list of options can be found, for example, in Wikipedia (http://en.wikipedia.org/wiki/YouTube).
Enter the Server address and port, select the direction of the transfer (Downlink/Uplink/Both), and enter the transfer duration. Finally, select Start to begin the transfer.
DU R IN G ME A SUR E ME N T S
23
Go to Nemo Handy-A to define the FTP settings. Tap the Tools button ( ) on the toolbar and select Make FTP transfer. After defining the settings, select Transfer to begin the data process.
Server defines the IP address for the FTP server, for example, 12.34.56.78. Port defines the port number for the FTP server, for example, 21. Passive, when selected, defines that the passive mode is used. When unselected, defines the active mode is used. Username and Password are required for the FTP server. Select whether the FTP file is Downloaded from the server or Uploaded from the phone to the server. File defines the name of the downloaded file. Directory defines the location for the uploaded file on the FTP server.
24
N e mo Han d y-A U s e r Ma nu al
Tap the Recent transfer button to access a list of previously used FTP transfers. This way you can quickly define FTP connection settings and the file used in the transfer.
If there are no previously used transfer settings, tap the Select host button. On the Select FTP connection page, select one of the predefined connections and tap Select. To create a new connection, see chapter Creating New FTP Connections.
DU R IN G ME A SUR E ME N T S
25
Tap the Tools button ( ) on the toolbar and select ICMP ping. After defining the settings, select Start to begin the ICMP ping test.
Host defines the ping host address. Repeats defines how many times the ping is repeated. Packet size defines the size of the ping package in bytes. Interval defines the interval in seconds between ping repeats.
26
N e mo Han d y-A U s e r Ma nu al
First define your access point. Select All apps | Settings | Wireless & networks | Mobile networks and choose the correct access point. Please follow the terminal manual to configure mobile data connections.
To open a script in Nemo Handy, select Menu | Scripts and select a script from the list. In case there are no scripts created, select Menu | New script and add script commands by tapping Add. For more information on script commands, see Creating Scripts).
Next, select a script file from the list of available scripts and press Load & Run. The selected script is loaded and started. If the Autologging option is selected, Nemo Handy-A will start logging when the script is started.
DU R IN G ME A SUR E ME N T S
27
A new Script view appears with information about the selected script.
If you did not start the script directly when it was loaded, select Menu | Scripts, choose the script you want to run and select Load & Run to start the script. Nemo Handy starts making the calls/data transfers as defined in the script file. The Script view displays the script status. The script will finish automatically but to interrupt the script, select Menu | Scripts, tap the current script to open and select Stop. If the Autologging option is activated, Nemo Handy will stop logging and save the file. You can follow the script by scrolling down all the way to the end of the script view. The script history view displays the progress of the script from beginning to end.
28
N e mo Han d y-A U s e r Ma nu al
Creating Scripts
You can create scripts with Nemo Handy-As integrated Script Editor. First define your access point. Select Menu | Scripts | Select Access Point and select your access point from the list. If you do not select it, Nemo Handy will use the default access point. Please follow the terminal manual to configure the mobile data connections. To avoid WLAN connections during measurements, user should disable WLAN connections before making measurements. Select Menu | Scripts and Menu | New script. An empty script is created and opened in the Script Editor main view. To add script commands, select Add.
When you select a command from the Add menu, a dialog with settings specific to the selected command is opened. Those dialogs are described in the following chapters. To move a command, select the command in the Script Editor main view, and press Up/Down. To edit a command, select the command in the Script Editor main view, and press Edit. To delete a command, select the command in the Script Editor main view, and press Delete. Nemo Handy-A supports parallel scripting of data transactions. This can be used to simulate real world user scenarios with multiple active data transactions of different type, such as, simultaneous uplink and downlink data transfers. Another application is the maximum throughput testing. In order to rule out possible effects of the test server, data can be downloaded simultaneously from multiple servers. In order to perform parallel data transfers in the script, add multiple transactions, such as FTP transfers, into the script. Interleave the start and end lines of the transactions so that the start lines of the transactions appear consecutively in the script transaction list and after that the end lines, respectively.
DU R IN G ME A SUR E ME N T S
29
To load the script, select Options | Load. Handy-A asks whether you want to run the script. Select Yes.
30
N e mo Han d y-A U s e r Ma nu al
To create a script that is repeated a number of times, select a script from the list, tap Edit and tap on Repeats.
Define how many times the script is repeated. In addition, you can set a maximum duration for the script. To define a minimum duration for the script, select the Duration option and enter the duration in minutes. Select the Max duration option and define how many minutes the script will be run. The script will be stopped either after the script has been repeated the defined number of times or the maximum duration is reached. Select Save.
DU R IN G ME A SUR E ME N T S
31
Before saving a script, it is advised that the script is verified, i.e. Nemo Handy will check that the script is valid and the script commands are in the correct order. Select Menu | Verify. If the script is valid, a Verification succeeded message is displayed. If there are errors in the script, Nemo Handy will tell you where the problem is.
To save the script, select Menu | Save or Save As. Enter a name for the script file and press OK.
32
N e mo Han d y-A U s e r Ma nu al
Phone number defines the recipient phone number. Call duration defines the duration (in seconds) of the call, unless used with Call End Condition (see below). Attempt timeout defines the maximum duration (in seconds) of the call attempt. Call end condition defines an end condition for the call based on the active system (Until system is GSM/UMTS/LTE), i.e. the call is terminated when a specific system becomes active. If a call end condition is defined, call duration countdown will begin only after the call end condition terminates the call. Thus it is recommended that also call duration is defined. This is to ensure that the events after the handover are logged as well. Call end conditions are supported with voice calls only.
DU R IN G ME A SUR E ME N T S
33
Add a script command for FTP transfer by selecting Add | FTP transfer in the Script Editor main view.
If you have saved FTP connection configurations, tap the Select FTP connection button. On the Select FTP connection page, select a connection from the list and tap Select. For more information on configuring new FTP connections, see Creating New FTP Connections. Attempt timeout defines the maximum duration (in seconds) of the transfer attempt. File (with Downlink only) defines the file name of the downloaded file. Path (with Uplink only) defines the destination folder for the transferred package. Size (with Uplink only) defines the size of the uploaded package in kilobytes. Max duration (seconds) defines the maximum duration of the FTP transfer.
34
N e mo Han d y-A U s e r Ma nu al
To add a script command for HTTP transfer, select Add | Packet Session in the Script Editor main view.
URL defines the file that will be downloaded. In upload only path is defined. Uplink/downlink defines the direction of transfer. Select the Download dynamic data from Nemo Server option to download automatically generated test data from Nemo Server. Size (with uplink only) defines the size of the uploaded package in kilobytes. Attempt timeout defines the maximum duration (in seconds) of the transfer attempt. Max duration (seconds) defines the maximum duration of the HTTP transfer.
DU R IN G ME A SUR E ME N T S
35
Tap the Recent transfer button to access a list of previously used HTTP transfers. This way you can quickly define HTTP connection settings and the file used in the transfer.
If there are no previously used transfer settings, tap the Select host button. Select HTTP or HTTPS.
On the Select HTTP/S connection page, select one of the predefined HTTP/S connections and tap Select. To create a new connection, see chapter HTTP/HTTPS Connection Settings.
36
N e mo Han d y-A U s e r Ma nu al
To add a script command for HTML browsing, select Add | HTML browsing in the Script Editor main view.
URL defines the URL of the page that will be browsed. Press the Choose previously loaded URL button to select a URL that has been used before.
Host defines the ping host address. Repeats defines how many times the ping is repeated.
DU R IN G ME A SUR E ME N T S
37
Packet size defines the size of the ping package in bytes. Interval defines the interval in seconds between ping repeats.
Destination defines the receiving phone number. Service center defines the service center address. Timeout defines the maximum duration (in seconds) of the SMS send attempt. In the Message field you can type the test message to be sent.
38
N e mo Han d y-A U s e r Ma nu al
To add a script command for using Iperf TCP or Iperf UDP, select Add | Iperf TCP transfer/Iperf UDP transfer in the Script Editor main view.
First define whether you are sending (Uplink) or receiving (Downlink) data or both. Server is the IP address used in Nemo Server. Server port refers to the port used by Nemo Server. For TCP and UDP protocols, the default port is 5001. Duration defines the length of the data transfer in seconds. Data size defines the length of the total data transfer in kilobytes; that is, the transfer finishes when the defined amount of data has been transferred. TCP window (KB) defines the size of the receive window during TCP/IP transmission. If it is too small, it can decrease the maximum data throughput, and if it is too high it can increase the retransmission round-trip time (RTT). To be able to avoid decrease of data throughput, the window size should be at least the maximum throughput multiplied by RTT. For example, with HSDPA with category 8 the maximum throughput is about 7.3 Mbit/s and RTT is about 100 ms. To avoid reduction of the throughput the TCP window size should be set at least to 7.3 Mbit/s * 0.1 s = 730 kbit = 91.25 kB. UDP datagram size defines the size of the UDP packet in bytes. It should be smaller than the maximum packet size of the lower layers to be able to avoid packet fragmentation in the lower layers. Packet fragmentation has a huge negative impact to the achieved data throughput and it should be avoided. On the other hand if too small UDP packet size is used the portion of the UDP and IP header increases which decreases the amount of transmitted user data with the result of smaller data throughput. Normally good maximum value for UDP datagram is a little bit less than maximum Ethernet packet size which is 1,500 bytes. A good default value for the UDP datagram size is 1,460 bytes. UDP bandwidth (kbps) defines how much data is attempted to be transmitted. Since UDP does not guarantee successful data transmission, it is not limited by maximum throughput of the lower layers. If higher bandwidth is used, the packet error rate (PER) increases. For example, if lower layers are capable of transmitting 100kbit/s and UDP bandwidth is configured to 400kbit/s, there should be a 75% packet error rate (only every fourth packet has been able to transmit successfully). Naturally UDP bandwidth should not be configured too small since it limits the maximum throughput that is not normally desired. Attempt timeout defines the time in seconds for how long Nemo Handy waits for the connection to be established. If a connection is not established within the defined time, connection attempt will fail.
DU R IN G ME A SUR E ME N T S
39
URL defines the link to the YouTube video. YouTube ID defines the ID of the selected video. Video duration defines for how long (in seconds) the video is streamed. Attempt timeout defines the time in seconds for how long Nemo Handy-A waits for the connection to be established. If a connection is not established within the defined time, connection attempt will fail.
40
N e mo Han d y-A U s e r Ma nu al
Tap the Search button to search for a video from YouTube. Select from the following options: search video, most popular, latest, or most viewed. Select a video from the list and tap the still image to add it to the script. When you run the script, the video will play for the defined duration.
Nested Script
A nested script is a script inside a script. Nested scripts enable you to run automated measurements combining multiple scripts. You can use nested scripts to run several scripts one after another. To add a script command for a nested script, select Add | Nested script in the Script Editor main view. Please note that you can add nested scripts only inside another nested script.
Script defines the script file that will be nested. Tap the field and select a script from the list.
DU R IN G ME A SUR E ME N T S
41
Run condition defines how long the script will be run. If you select Until finished, the script will be run until it is finished. If you select Max time, you will need to define in minutes the maximum duration of the script. Repeats defines how many times the script is repeated.
Wait
To add a pause in the script, select Add | Wait in the Script Editor main view.
Wait time defines the wait period in seconds. Wait condition defines an indefinite wait period until a specific system is active (None, Until system is GSM/UMTS/LTE). If a Wait Condition is defined, it is recommended that also a wait period (Wait) be defined. This is to ensure that logging starts only after handover has successfully occurred.
42
N e mo Han d y-A U s e r Ma nu al
AUTOMATED TESTING
Nemo Handy-A offers the automated testing mode, i.e., the ability to schedule Nemo Handy-A to perform measurements automatically using a calendar view. During the automated testing mode, the data views are viewable, but you will not be able to control the measurement or use forcing features. Also, the log files can be automatically sent to a FTP or HTTPS server. In addition to running standalone automated testing, Nemo Handy-A can be connected with the Nemo Autonomous system and remotely configured and controlled by Fleet Manager. For more information on the Nemo Autonomous system, please refer to the Nemo Autonomous user manual.
Phone number defines the phone number of the Nemo Handy-A mobile terminal. Startup maintenance defines whether maintenance is performed automatically when Nemo Handy-A is starting. During maintenance sessions, Nemo Handy-A unit uploads reports and measurement files to a server. Low maintenance priority defines the priority of a maintenance session, i.e. maintenance can be delayed if a new measurement session is set to run immediately after the previous one or if a measurement is still running when a maintenance sessions is scheduled to take place. Maintenance interval defines in minutes how often maintenance is performed if the measurement is in idle mode. Unit prefix defines the prefix attached to the measurement file name. Status SMS number defines the number where SMS reports are sent to. Applicable only when Nemo Handy-A is used with the Nemo Autonomous system.
DU R IN G ME A SUR E ME N T S
43
Error report number defines the number where error reports are sent to. Applicable only when Nemo Handy-A is used with the Nemo Autonomous system. The possible error messages are: No Packet Connection: check that APNs are configured correctly No Contact FTP: check that IP address is correct and that the server is running Cannot Login FTP: check that the server is running Invalid Configuration: check measurement configuration Configuration Not Found: check that the configuration file is available on the server
Maintenance FTP
The FTP server address needs to be entered manually. Select Menu | Settings | Maintenance FTP and enter the FTP server information. If no server is set up, the log files will be stored on the Nemo Handy-A terminal.
Address defines the IP address of the server. Port defines the host port. Username defines the host site logon user name Password defines the host site logon password. Mode defines whether active or passive mode is used in FTP connection. When this is done, go to the Calendar view and tap session. on the toolbar to initiate maintenance
44
N e mo Han d y-A U s e r Ma nu al
The view should look as the image below. Tap the and status views.
If the unit has never been used with the Nemo Server before, the Self-check view will look like in the screen below.
After about ten minutes, the unit has been automatically registered to server and is ready for use. You can now copy new autoconfig.xml file to sdcard\Nemo\Handy manually.
DU R IN G ME A SUR E ME N T S
45
Start date, Start time, End date, and End time define the start and end date and time of the measurement session. Answer incoming calls option allows Nemo Handy-A to answer incoming calls in automated mode. Needed in mobile to mobile call testing. Everyday session defines whether the measurement session is to be repeated every day (until a different measurement configuration is received). Manual mode allows you to define the measurement as a manual measurement session. Script repeats defines how many times the script will be run, defining the length of the measurement session based on repeats rather than a fixed end time. For example, a voice call can be defined to be performed 100 times after a defined start time. After the repeats have been performed, Nemo HandyA will upload the measurement file to the server. If script repeat is set to -1, the script is repeated for the duration the measurement session.
46
N e mo Han d y-A U s e r Ma nu al
Measurement split duration (min) defines in minutes the splitting of the measurement session into multiple logfiles. When set to -1, the whole measurement session will be gathered in one logfile. Immobile limit (minutes) defines the measurement to be stopped after the probe has been immobile for the defined time. The feature is disabled if the limit is set to 0 or if the GPS does not have a fix. No GPS fix limit (minutes) defines the measurement to be stopped after the GPS fix has been lost for the defined amount of minutes. Script file opens a list of all available scripts, allowing you to select the script you want to run. If there are no scripts in the view, you are able to browse for them. Select a script by tapping Select. Session prefix defines the prefix of the measurement file created during the new measurement session. Session start SMS info, when set to Yes, defines an SMS to be sent to Fleet Manager when the measurement session has begun/ended. Applicable only when Nemo Handy-A is used with the Nemo Autonomous system. Send report defines whether a report is to be uploaded during the maintenance session. Applicable only when Nemo Handy-A is used with the Nemo Autonomous system. Send measurements defines whether measurement files are to be sent to the server after the measurement session. Load configuration defines whether a configuration file is to be downloaded during the maintenance session. Applicable only when Nemo Handy-A is used with the Nemo Autonomous system. Allow script connection defines when the phone is allowed to make voice calls and data transfer attempts. Always The phone will make voice calls and data transfer attempts always, also in roaming situation. In service The phone will make voice calls and data transfer attempts only when it finds a network. In home network The phone will make voice calls and data transfer attempts only when it is in the home network. After session settings have been defined, press the Back button on your mobile device. A dialog prompting whether you want the changes saved to the server during the next maintenance is displayed. Select Yes.
DU R IN G ME A SUR E ME N T S
47
The maintenance or measurement session is now displayed in the Session properties view within the Calendar View.
The session is also displayed in the Calendar views monthly view and weekly view as a time scale, ranging from the start time to the end time. Tap to switch between views.
To edit an existing maintenance or measurement session, tap Edit in the Session properties view or tap on the toolbar. To delete a session, select Delete in the Session properties view. To initiate a maintenance session manually, select from the calendar view toolbar.
48
N e mo Han d y-A U s e r Ma nu al
DU R IN G ME A SUR E ME N T S
49
FORCING FEATURES
Nemo Handy-A supports band locking, system locking, and preferred channel locking (UMTS only). Support for the locks is terminal-specific so please refer to the Nemo Handy-A data sheets to see which locks are supported by your test device. Tap the Tools button and select Forcing.
50
N e mo Han d y-A U s e r Ma nu al
The Forcing dialog is opened with fields for system lock, band lock, and preferred channel lock (UMTS).
The Status view displays the status for the different locks.
System Lock
To activate the system lock, tap the System field.
DU R IN G ME A SUR E ME N T S
51
Band Lock
To activate the band lock, tap the Bands field.
All supported bands from the systems supported by the terminal are displayed. However, the terminal does not necessarily support all the listed bands. If you are trying to lock the phone to a band that the phone does not support, the phone will revert back to default. Band lock overrides the system lock when used simultaneously. For example, if you lock to the WCDMA 2100 band, you cannot choose the GSM system lock. Please note that the device needs to be powered off and on in order to activate and release the band lock. Also note that the lock is not released by rebooting the device or by exiting Nemo Handy-A. The lock can only be released with Nemo Handy-A.
52
N e mo Han d y-A U s e r Ma nu al
IP CAPTURE
Note that this functionality is available only if your Nemo Handy-A license supports it. Application level data can be captured with Nemo Handy-A. The data is collected in a separate log file in .pcap format. Pcap files can be processed with Nemo Outdoor, Nemo Analyze, or Wireshark. By default, full IP capture, including IP and all above layers are captured. Pcap log files can be very large if no filtering is applied. Therefore, it is practical in most cases to apply filtering to capture only the protocol layers of interest. Capture filter rules are read from a text file. Rules must be defined in the standard Wireshark filter format.
DU R IN G ME A SUR E ME N T S
53
IP capture option activates/deactivates IP packet capturing. IP capture max packet size defines the maximum size (in bytes) captured from each packet. Select the IP capture filter option to filter the logged IP capture data. IP capture filter rules defines a .txt file containing the filter rules in the standard Wireshark filter format. Please refer to Wireshark documentation for more information. IP capture is started whenever you start logging with Nemo Handy-A and stopped when logging is stopped. You can upload IP capture files to a server by selecting the Upload packet capture files option in the Log file name dialog that appears when you stop logging.
INDOOR MEASUREMENTS
Note that this functionality is available only if your Nemo Handy-A license supports it. You can view indoor maps in Nemo Handy-A and plot the measurement route on the map with markers.
54
N e mo Han d y-A U s e r Ma nu al
Select a floorplan and tap Edit. On the Tab file settings page you can define the dimensions of the floorplan and select a route plan.
Layer name defines the floorplan name. The name can be edited. Select the Display route plan option to display a route plan on the indoor map. Route plan defines the route plan file (.rpf) displayed on the indoor map. File type defines whether the floorplan dimensions are defined in meters (width/height) or in geodetic coordinates. Width defines the floorplan width in meters. Nemo Handy-A enters a default value (number of pixels in the image divided by ten) for the field, but you should enter the correct value. Height defines the floorplan height in meters. Nemo Handy-A enters a default value (number of pixels in the image divided by ten) for the field, but you should enter the correct value.
DU R IN G ME A SUR E ME N T S
55
Longitude defines the geodetic coordinates of the left and right sides of the map. Enter coordinates in decimal degrees (e.g. 25.4714). Latitude defines the geodetic coordinates of the top and bottom sides of the map. Enter coordinates in decimal degrees (e.g. 25.4714). Next, define indoor settings from the Indoor Map settings view (see Indoor Map). After defining indoor settings, you are ready to begin measurements.
The floorplans (.tab) are listed on the Floorplans page. Select a floorplan and tap the Up and Down buttons to rearrange to order of the floors on the map.
56
N e mo Han d y-A U s e r Ma nu al
Select a floor/tab file and tap Edit. On the Tab file settings page you can select a route plan to be displayed on the map.
Next, define indoor settings from the Indoor Map settings view (see Indoor Map). After defining indoor settings, you are ready to begin measurements.
DU R IN G ME A SUR E ME N T S
57
You can view indoor maps in Nemo Handy-A and plot a measurement route on the map with markers. To pan the map through the touchpad, lock the map in its position by tapping the map is locked the color of the lock button changes to black. on the toolbar. When
You are able to zoom in and out by tapping and buttons on the toolbar. Alternatively, you can pinch the screen using two fingers (for example, thumb and index finger) to zoom in or zoom out when viewing a map. When you are logging, you are able to draw a route on the map by placing markers along the route by tapping on the toolbar. To remove last marker, tap . If the Draw route setting is on in the Indoor Map Settings, the markers will be connected to form a route. Note also that Nemo Handy-A must be logging for you to be able to place markers on the route. You are able to view the measured route with color-coded parameter values in real-time on indoor maps. You can also observe the values of user-configurable network parameters from the route coloring on the map and define which color refers to which parameter value. Tap Menu | Parameter. Note that if the Parameter item is not visible in the indoor map menu, go to Settings | Indoor Map and select Yes for Indicate parameter on route color and select a Route parameter.
58
N e mo Han d y-A U s e r Ma nu al
Select a parameter and the route will be colored accordingly. See Defining Route Parameters for defining custom route parameters and color sets. After the measurements have been performed, stop logging by selecting Menu | Stop logging.
Route Plans
Route plans are useful when you want to follow a certain route while performing a measurement. Route plans are created with Nemo Outdoor. You can create route plans automatically from a measurement in playback mode, or you can manually create one with the Add waypoint functionality both during a measurement and during playback. Please refer to the Nemo Outdoor user manual for more information. If you have previously created and saved a route plan (.rpf), you can open it by selecting Menu | Settings | Indoor Map | Floorplans. Tap a floorplan on which you would like to view the route plan and tap Edit.
DU R IN G ME A SUR E ME N T S
59
On the Tab file settings page, select the Display route plan option and choose a route plan file (.rpf).
The route plan (.rpf) with waypoints is now displayed on the indoor map.
Start logging by selecting Menu | Start logging. Press the marker button to move from one waypoint to the next. A marker is placed on each waypoint and the route is drawn on the map.
60
N e mo Han d y-A U s e r Ma nu al
With the Automatic Panning tool you can focus the view so that the previous, current, and next marker are visible on the map. The focus changes as you move along the route plan. The tool button appears at the top left corner of the screen when you start logging and lock the Indoor map view.
OUTDOOR MEASUREMENTS
First, define outdoor map settings by going to the Outdoor Map settings view by selecting Menu | Settings | Outdoor Map (see Outdoor Map). Select the map file Start logging by selecting Menu | Start logging.
You can view outdoor maps in Nemo Handy-A and plot a measurement route on the map with markers. Pan the map through the touchpad by locking the map in its position by tapping When the map is locked the color of the lock button changes to black. on the toolbar.
DU R IN G ME A SUR E ME N T S
61
You are able to zoom in and out by tapping and buttons on the toolbar. Alternatively, you can pinch the screen using two fingers (for example, thumb and index finger) to zoom in or zoom out when viewing a map. Tap to focus on your current location. Tap the Menu button to open the Outdoor map menu.
With the Clear route tool you can remove the measurement route from the map. Load map area allows you to load map tiles to the cache to avoid data transfers during testing, making zooming less time-consuming during measurements. Select the Reload existing map tiles option and Start.
62
N e mo Han d y-A U s e r Ma nu al
You are able to see the measured route with color-coded parameter values in real-time on live map. You can also observe the values of user-configurable network parameters from the route coloring on the map and define which color refers to which parameter value. Tap Menu | Parameter.
Select a parameter and the route will be colored accordingly. To quickly switch between different parameters, tap on the toolbar. See Defining Route Parameters for defining custom route parameters and color sets. To stop logging, select Menu | Stop Logging. Once the logging is stopped, you are able to choose whether to Keep, Rename or Delete the resulting log file. The saved log files along with captured screenshots and indoor marker files are saved to File explorer (see File Explorer for more information).
DU R IN G ME A SUR E ME N T S
63
Go to the BTS page. Select a BTS file and select Yes in Use BTS file. If you wish to see detailed information about the individual cells, tap the Cell info item and select the information to be displayed.
A map with the BTS site icons is displayed. During measurement, the BTS that the measurement device is connected to is highlighted with the color that you selected for Active cell in the Outdoor Map settings page. The terminal needs to have a GPS fix and the zoom factor needs to be at least 8 before the BTS icons are displayed.
64
N e mo Han d y-A U s e r Ma nu al
To view information on individual cells, lock the map view, tap a BTS icon, and from the Select sector dialog, select a sector.
DU R IN G ME A SUR E ME N T S
65
Cell information for the selected sector will be displayed on the map.
Select Menu | More | BTS data to view a list of all BTS sites in the current BTS file.
66
N e mo Han d y-A U s e r Ma nu al
Use Case 1 Outdoor Map with Route, BTS, and Notification Icons
This use case describes how to play back a measurement file on an outdoor map and to view BTS icons and notification icons on the map. First make the outdoor map visible. Select Menu | Settings and go to the Outdoor Map page. Select Yes for the Show outdoor map option. On the same page, select Yes for the Show notification icons on map option and Always for the Draw route option. Make sure that you have a GPS connected to the system or use the terminals internal GPS. Select Menu | Settings and go to the GPS page. Select a GPS in the GPS source field. Next select the BTS file. Select Menu | Settings and go to the BTS page. Select a BTS file and select Yes for the Use BTS file option. Make sure that the BTS file matches the SIM card you are using in the Nemo Handy-A terminal. They must from the same operator. Also note that the BTS file needs to be from the same area where you made the measurement. Close the Settings dialog and go the Outdoor map view. Select Menu | More | File explorer. Select a measurement file and select Menu | Play. Once the file has been loaded the route and notification icons will appear on the map. If the BTS files are not visible, check that your terminal has a GPS fix and that the zoom factor is at least 8.
DU R IN G ME A SUR E ME N T S
67
You will see a list of available parameters. Select a parameter and tap Color set.
First select the technology for which the parameter should be displayed. Note that all parameters are not available for all technologies.
68
N e mo Han d y-A U s e r Ma nu al
If there is no readymade color set, tap the Add new button. Then tap the range to edit the values.
The Value range editor displays the minimum and maximum values of the selected parameter. These values cannot be edited. Add a parameter value by tapping the + button. The value can be anything between the min and max value. Just tap the value field and type in a new value. Tap OK and the value is added in the Value range editor.
Define a color for the value by tapping the color field below the value. Pick a color and tap the circle in the middle.
DU R IN G ME A SUR E ME N T S
69
In the example below, values 50-20 are colored green, values 20-0 yellow, 0- -25 orange, and -25 -50 red. After you have defined all values and colors, tap the Back button.
The Color set editor will display the new values and colors. Tap Ok and Save.
The new color set will be available in the Route parameter dialog.
70
N e mo Han d y-A U s e r Ma nu al
FILE EXPLORER
Log files, captured screenshots, and indoor map markers are saved to File explorer that can be found by selecting Menu | File explorer.
File explorer displays a list of various Handy-related files. The contents can be filtered by selecting/deselecting the configs, maps, results, and scripts items at the top of the screen. You can also type a filter text in the filter field and the list will display items that match the filter. The list can be organized by tapping the By name/size/date button.
Configs lists Nemo Handy-A configuration files (.xml) Maps lists map image files (.bmp, .jpg), MapInfo tab files (.tab), and route plans (.rpf) Results lists log files (.nbl), screenshots (.png, .jpg), and marker files (.mrk). Tap the Logs only button to display only the .nbl files. Tap the Scrshot only button to display screenshots only. Scripts lists Nemo Handy-A script files (.nsf)
DU R IN G ME A SUR E ME N T S
71
To delete files from the file explorer, select files by tapping the check mark next to the file and select Menu | Remove. To remove all files at once, select Menu | Select all and then Menu | Remove.
To play back measurement files, select a file from the list and select Menu | Play. For more information on playback, see Playback. You can also upload measurement files through the file explorer on an FTP server. Select a file and select Menu | Upload. For more information on uploading measurements on an FTP server, see Uploading Log files on Server. To close the file explorer, select Menu | Close.
PLAYBACK
To play back measurement files, open the File explorer (Menu | File explorer). Select a file from the list and select Menu | Play.
72
N e mo Han d y-A U s e r Ma nu al
Nemo Handy-A will load the file and start the playback. The playback controls will appear at the bottom of the view. You can hide and display them by tapping the Playback icon in the toolbar. With the + and controls you can adjust the playback speed. You can also Pause and Resume the playback. With the slider in the middle you can scroll to a specific point in the measurement.
The Notification History view can also be used to jump to a specific point in the measurement. Tap a notification and select Jump to notification time. The playback will jump to the point where the notification occurred.
DU R IN G ME A SUR E ME N T S
73
74
N e mo Han d y-A U s e r Ma nu al
PARAMETER MENU
Through the Parameter menu you can edit the appearance of data views. Please note that the contents of the menu depends on the view type (line, text, etc.).
DU R IN G ME A SUR E ME N T S
75
Set Active
Lock a line graph view by tapping and select a parameter in the line view by tapping the value. Tap and select Set active to set the selected parameter active. This means that the scales will display values for that parameter.
Auto Scale
In line graphs you can use the Auto scale function. First, lock the line view by tapping the lock button on the toolbar. Select a parameter in the line view by tapping the value. When a scalable parameter is selected, tap the Parameter button and select Auto scale from the pop up view.
Note that you can define the scaling individually for each parameter in the line graph. Select None and the scales return to normal. Select High and Nemo Handy-A changes the scales and zooms in on the view so that the line is at the top of the graph and the minimum value is at the bottom of the scale. The symbol changes to . Select Low, and Nemo Handy-A changes the scales and zooms in on the view so that the line is at the bottom of the graph and the maximum value is at the top of the scales. The symbol changes to . Select Both and Nemo Handy-A checks the minimum and maximum values for the graph from the visible area and zooms in on the view so that the line is in the middle. The symbol appears next to the parameter name at the top of the view.
Number Format
To change the number format of parameters, lock a view by tapping the lock button, select a parameter value and tap the Parameter button . Select Number format. Select the number format and tap the return button.
76
N e mo Han d y-A U s e r Ma nu al
If you would like to save this setting so that the parameter will now on be displayed in the selected format, tap the Parameter button again and select Save configuration. Save the changes in the configuration file.
STATUS VIEW
Logging status displays the current recording status. Log file size displays the size of the measurement file in bytes. Log file name displays the measurement file name. Log file path displays the location where the measurement files are stored on the memory card. Free storage displays the available memory card memory space. Free memory displays the current amount of free RAM. Script status displays the current status of the script. Script file displays the name of the script file. GPS status displays the status of the GPS receiver. IMEI displays the International Mobile Subscriber Identity (IMEI) number of the mobile terminal. The IMEI number is used by the GSM network to identify valid devices. IMSI (International Mobile Subscriber Identity) displays a unique number associated with all GSM and UMTS network mobile phone users. It is sent by the phone to the network. System lock displays the system lock status.
N E MO HA N DY -A VIE W S
77
Band lock displays the band lock status. Carrier lock displays the channel lock status.
The second Status page displays information about the current access point.
SCRIPT VIEW
Script file displays the name of the script file. Status displays the current status of the script. Position shows the current position in the script Repeat displays how many times the script is repeated and the ordinal number of the current repeat. Command displays which script command is currently running. Active transactions displays the active transactions taking place.
78
N e mo Han d y-A U s e r Ma nu al
GPS
The GPS view is available only if the license supports a GPS. Source defines the GPS source Latitude/Longitude displays the latitude/longitude coordinates. Altitude displays the current elevation in meters. Heading displays the direction in which a person or vehicle is moving. Distance displays the distance travelled from the starting point. Speed displays the current velocity of the test unit in kilometres per hour. GPS status displays the current status of the GPS, i.e., if there is a fix. GSP time displays the time from the GPS. This feature can be enabled and disabled from Menu | Settings | GPS | Use GPS time. Satellites displays the number of satellites currently visible.
N E MO HA N DY -A VIE W S
79
GPS status displays the current status of the GPS, i.e., if there is a fix. Speed displays the current speed in km/h. Distance displays the distance travelled from the starting point.
NOTIFICATION HISTORY
The Notification History view displays a list of notifications and their timestamps. Unlock the view (tap the lock icon) to scroll the view.
80
N e mo Han d y-A U s e r Ma nu al
INDOOR MAP
You can view indoor maps in Nemo Handy-A and plot a measurement route on the map with markers. To pan the map through the touchpad, lock the map in its position by tapping on the toolbar. When the map is locked the color of the lock button changes to black. To unlock the map, tap again the lock button. You are able to zoom in and out by tapping and buttons on the toolbar. Alternatively, you can pinch the screen using two fingers (for example, thumb and index finger) to zoom in or zoom out when viewing a map. You are able to draw a route on the map by placing markers along the route by tapping on the toolbar. To remove last marker, tap . If the Draw route setting is on in the Indoor Map Settings, the markers will be connected to form a route. Note also that Nemo Handy-A must be logging for you to be able to place markers on the route.
N E MO HA N DY -A VIE W S
81
OUTDOOR MAP
You can pan the map through the touchpad by locking the map in its position by tapping on the toolbar. When the map is locked the color of the lock button changes to black. To unlock the map, tap again the lock button. You can zoom in and out by tapping and buttons on the toolbar. Alternatively, you can pinch the screen using two fingers (for example, thumb and index finger) to zoom in or zoom out when viewing a map. Tap to focus on your current location.
You can view the measured route with color-coded parameter values in real-time on live map. To observe different parameters, tap . The parameters and the related color sets are userconfigurable. See Defining Route Parameters for more information.
82
N e mo Han d y-A U s e r Ma nu al
You can pan the view by locking the map in its position by tapping . When the view is locked the color of the lock button changes to black. To unlock the view, tap the lock button again. You are able to zoom in and out by tapping and buttons on the toolbar. Alternatively, you can pinch the screen using two fingers (for example, thumb and index finger) to zoom in or zoom out when viewing a map. Tap on the toolbar to load a web page. To go back to the local home page start view, tap .
BTS VIEW
To display the BTS view, select Menu | Settings | BTS. Select Yes for Show BTS view. Cell name displays the name of the active cell. Site name displays the name of the active base station. Distance displays the distance in km to the active base station. BTS CI displays the cell identity of the active base station.
N E MO HA N DY -A VIE W S
83
YOUTUBE VIEW
In the YouTube view you can select to stream YouTube videos. See chapter Manual YouTube Testing for more information on YouTube testing.
STATISTICS VIEWS
The statistics views display statistics for various measurement events. The statistics views display some voice and video call related and application testing related statistics. To reset the statistics view, tap on the toolbar to open the Tools view and select Reset statistics.
84
N e mo Han d y-A U s e r Ma nu al
SIGNALING VIEW
Signaling messages view displays a list of signaling messages. Lock the view by tapping the lock icon and tap an individual message to view the timestamp for that message or L3 messages in decoded form.
N E MO HA N DY -A VIE W S
85
The Voice Quality view is available only if the license supports VQ measurements. MOS DL displays the downlink MOS score. BLER DL displays the downlink block error rate. AMR codec downlink displays the AMR mode in downlink direction.
WIFI VIEW
The WiFi view is available only if the license supports WiFi measurements. Activate WiFi scanning by selecting Yes for the Active WiFi scanning option (Settings General).
86
N e mo Han d y-A U s e r Ma nu al
WiFi state defines the current state of the WiFi network. The possible states are: WIFI_STATE_DISABLING WIFI_STATE_DISABLED WIFI_STATE_ENABLING WIFI_STATE_ENABLED WIFI_STATE_UNKNOWN
WiFi connection displays the current status of the WiFi connection. The possible states are: CONNECTING CONNECTED SUSPENDED DISCONNECTING DISCONNECTED UNKNOWN
SSID displays the WLAN service set identifier. BSSID displays the basic service set identifier, also known as WLAN MAC address. Link speed displays the maximum transfer rate in Mbit/s. IP address displays the current IP address. The view also displays a list of available WiFi networks and the frequency, channel, security mode, and RSSI per network.
Active RSSI displays the RSSI value in dBm for the current WLAN network. Link speed displays the maximum transfer rate in Mbit/s.
N E MO HA N DY -A VIE W S
87
System displays the current cellular system, e.g., GSM 1800. Cell name displays the name of the active cell. Distance to BTS displays the distance in km to the active base station. Channel displays the current channel number. CI displays the 16-bit cell identification code. BCCH displays the broadcast control channel number. BSIC displays the base station identity code. RX Level displays the RX level full value when the mobile is in idle mode and the RX level sub value when a call is connected. Values range from -120 to -10 dBm. RX Quality displays the RX quality full value when the mobile is in idle mode and the RX quality sub value when a call is connected. Values range from 0 to 7. C1 & C2 display the C1 and C2 values. N1 Channel displays the channel number for the first neighbor. N1 RX Level displays the RX level for the first neighbor.
88
N e mo Han d y-A U s e r Ma nu al
LAC displays the location area code. MCC displays the mobile country code. MNC displays the mobile network code. TA displays the timing advance value. Values range from 0 to 63. MSP displays the mobile station Tx power. Values range from 0 to 32. RLT displays the radio link timeout. AMR Init Codec displays the AMR initial codec mode. Alternatives are 4.75, 5.15, 5.9, 6.7, 7.4, 7.95, 10.2, and 12.2. GSM AMR Codec UL/DL displays the currently used AMR codec for sending and receiving. LQE displays the link quality estimate. Values range from 0 to 32.
N E MO HA N DY -A VIE W S
89
The Cell measurements 1/5 view (neighbor bar view) for GSM displays the channel number, BSIC, and RX level for the serving and neighbor channels. The serving channel is displayed first on the list (in black). The serving channel bar is color coded. RX level: If the value goes below -95, the bar color changes from blue to red.
The Cell measurements 2/5 view (neighbor line view) for GSM displays the channel number and RX level for the serving and neighbor channels. The serving channel is displayed first on the list (in black). The RX level line for the serving channel is displayed in bold.
90
N e mo Han d y-A U s e r Ma nu al
The Cell measurements 3/5 view displays the channel number, CI (cell identity), BSIC, C1, C2, RX level, and LAC (location area code) for the serving (first on list) and neighbor channels.
The Cell measurements 4/5 view (hopping channels view) displays a list of hopping channels and the channel number, C/I, and RX level per hopping channel.
N E MO HA N DY -A VIE W S
91
The Cell measurements 5/5 view (inter-system line view) displays for GSM the channel number, BSIC, and RX level for the serving and best neighbors and for UMTS the scrambling code, RSCP, and Ec/N0 for the active set and for best pilots in monitored set. The serving channel and the active set are displayed first on the lists (in black).
GSM View
RX Level displays the RX level full value when the mobile is in idle mode and the RX level sub value when a call is connected. Values range from -120 to -10 dBm. RX Quality displays the RX quality full value when the mobile is in idle mode and the RX quality sub value when a call is connected. Values range from 0 to 7. LQE displays the link quality estimate. Values range from 0 to 32.
92
N e mo Han d y-A U s e r Ma nu al
The data throughput line views display the application data throughput in kilobits per second for UL and DL directions. The value is also displayed as a line. Note that you need to have a data transfer on to see data in these views.
The gauge view displays the application throughput in downlink and in uplink direction in kb per second and the amount of data transferred in downlink and in uplink direction in bytes.
N E MO HA N DY -A VIE W S
93
PPP Throughput views display the downlink and uplink throughput values in kbps. The value is calculated based on the SDUs (service data units) that are successfully transferred through the PPP layer. Missing and erroneous PPP packets are excluded from the throughput calculation.
App. Throughput DL displays the application throughput in downlink direction in kb per second. iPerf PER DL displays the downlink packet error rate, i.e., the percentage of erroneously transferred packets
from the total number of transferred packets.
iPerf Jitter DL displays the packet jitter downlink in ms. App. Throughput UL displays the application throughput in uplink direction in kb per second. iPerf PER UL displays the uplink packet error rate, i.e., the percentage of erroneously transferred packets
from the total number of transferred packets.
94
N e mo Han d y-A U s e r Ma nu al
App. Throughput DL displays the application throughput in downlink direction in kb per second. YouTube Buffer displays the percentage of the video loaded in the buffer. YouTube Play State displays the current state of the video streaming.
Coding DL/UL displays the CS data channel coding for downlink/uplink directions. Alternatives are 9.6 and 14.4.
N E MO HA N DY -A VIE W S
95
System displays the current cellular system, e.g., UMTS FDD. Cell name displays the name of the active cell. Distance to BTS displays the distance in km to the active base station. Cell ID (16-bit) displays the 16-bit cell identification code. RNC displays the radio network controller ID. LAC displays the location area code. MCC displays the mobile country code. MNC displays the mobile network code. UARFCN displays the radio frequency channel number in use. RRC State displays the RRC state. Alternatives are Idle, URA PCH, Cell PCH, Cell FACH, and Cell DCH. Active Ec/No displays the active Ec/No value. Active RSCP displays the active RSCP value. Active Scrambling Codes displays the active scrambling code. Monitored Ec/No displays the monitored Ec/No value. Monitored RSCP displays the monitored RSCP value. Monitored Scrambling Codes displays the monitored scrambling code values.
96
N e mo Han d y-A U s e r Ma nu al
BLER displays block error rate. SIR displays the signal-to-interference ratio. Values range from 50 to 50. TX Power displays the TX power level in dBm. Values range from 30 to -120. DL/UL Pwr Up % displays the percentages of downlink (DL) and uplink (UL) power up commands. AICH Status displays the RACH message transmission result. Preamble Count displays the transmitted preamble count. Values range from 1 to 65. RACH TX Power displays the RACH message power in dB. AMR Codec UL/DL displays the AMR mode in uplink (UL) and downlink (DL) directions. Alternatives are 4.75, 5.15, 5.9, 6.7, 7.4, 7.95, 10.2, and 12.2.
CQI displays the Channel Quality Indicator. Number of codes displays the number of HS-PDSCH channelization codes. Modulation displays the ratio of QPSK/16QAM activity. Transport Block Size displays the Transport Block Size Indicator
N E MO HA N DY -A VIE W S
97
MAC BLER displays MAC block error rate. MAC Troughput Downlink displays the MAC downlink data transfer rate in kilobits per second. Activity Rate displays the downlink Activity rate.
E-TFCI displays information about the transport block set size. E-DCH Transport Block Size displays the average of transport block size used during the previous reporting period. Activity Rate displays the downlink activity rate. Serving Grant Index defines how much power is given for the uplink data transmission. The network controls current serving grant using absolute and relative grants. TTI defines the transmission time interval. SI Total E-DCH Buffer Status identifies the total amount of data available across all logical channels for which reporting has been requested by the RRC, and indicates the amount of data in a number of bytes that is available for transmission and retransmission in the RLC layer. Happy bit - the happy bit status is periodically reported to the network to indicate when the mobile has enough power to transmit current data buffers in a predefined time period. MAC-e Retransmission displays the ratio of retransmitted PDUs and all transmitted PDUs in the MAC-e layer. E-DCH DTX defines the ratio of non-transmitted TTIs and all TTIs with HSUPA.
98
N e mo Han d y-A U s e r Ma nu al
The Cell measurements 1-3 views (neighbor bar and inter-system line views) for WCDMA display the scrambling code, RSCP, and Ec/No for the serving and neighbor channels. The serving channel is displayed first on the list (in black). The active cell bars in view 1/5 are color coded. Ec/N0: Value goes below -15, bar color changes from blue to red. RSCP: Value goes below -100, bar color changes from blue to red.
The Cell measurements 4/5 view displays the Channel number, Scrambling Code, Ec/No, and RSCP for the serving (first on list) and neighbor channels.
N E MO HA N DY -A VIE W S
99
The Cell measurements 5/5 view (inter-system line view) displays for GSM the channel number, BSIC, and RX level for the serving and best neighbors and for WCDMA the scrambling code, RSCP, and Ec/N0 for the active set and for best pilots in monitored set. The serving channel and the active set are displayed first on the lists (in black).
WCDMA View
The WCDMA view displays the carrier RSSI value, TX power level, and 1AS RSCP (the best RSCP in the active set), block error rate value in downlink direction, percentages of downlink (DL) and uplink (UL) power up commands, and signal-to-interference ratio.
100
N e mo Han d y-A U s e r Ma nu al
The data throughput line view displays the block error rate value in downlink direction and the application throughput in downlink and in uplink direction in kb per second.
The gauge view displays the application throughput in downlink and in uplink direction in kb per second and the amount of data transferred in downlink and in uplink direction in bytes.
PPP Throughput views display the downlink and uplink throughput values in kbps. The value is calculated based on the SDUs (service data units) that are successfully transferred through the PPP layer. Missing and erroneous PPP packets are excluded from the throughput calculation.
N E MO HA N DY -A VIE W S
101
App. Throughput DL displays the application throughput in downlink direction in kb per second. iPerf PER DL displays the downlink packet error rate, i.e., the percentage of erroneously transferred packets
from the total number of transferred packets.
iPerf Jitter DL displays the packet jitter downlink in ms. App. Throughput UL displays the application throughput in uplink direction in kb per second. iPerf PER UL displays the uplink packet error rate, i.e., the percentage of erroneously transferred packets
from the total number of transferred packets.
App. Throughput DL displays the application throughput in downlink direction in kb per second. YouTube Buffer displays the percentage of the video loaded in the buffer. YouTube Play State displays the current state of the video streaming.
102
N e mo Han d y-A U s e r Ma nu al
MAC Throughput displays MAC throughput. MAC BLER displays MAC block error rate. 16QAM/QPSK% displays the relative ratio of 16QAM and QSPK modulation activity. Number of Codes displays the number of HS-PDSCH channelization codes. CQI displays the Channel Quality Indicator.
MAC-e Throughput displays MAC throughput. MAC-e retransmission displays the ratio of retransmitted PDUs and all transmitted PDUs in the MAC-e layer. E-DCH Transport Block Size displays the average of transport block size used during the previous reporting period. Activity Rate displays the downlink Activity rate. TX Power displays the TX power level in dBm. Values range from 30 to -120.
N E MO HA N DY -A VIE W S
103
The Happy Bit status is periodically reported to the network to indicate when the mobile has enough power to transmit current data buffers in a predefined time period. Activity Rate displays the downlink activity rate. SI Total E-DCH Buffer Status identifies the total amount of data available across all logical channels for which reporting has been requested by the RRC, and indicates the amount of data in a number of bytes that is available for transmission and retransmission in the RLC layer.
Table 1. displays the relative ratio of QSPK, 16QAM and 64QAM modulation activity for the current data session. Table 2. displays the relative ratio of QSPK, 16QAM and 64QAM modulation activity for the entire measurement.
104
N e mo Han d y-A U s e r Ma nu al
System displays the current cellular system. Cell name displays the name of the active cell. Distance to BTS displays the distance in km to the active base station. Cell ID displays the E-UTRAN cell global ID (ECGI). eNodeB/CID displays the eNodeB ID and cell ID. TAC displays the tracking area code. MCC displays the mobile country code. MNC displays the mobile network code. EARFCN displays the radio frequency channel number in use. Carrier RSSI displays the carrier RSSI value. Values range from -120 to -10. Serving SNR displays the SNR (signal to noise ratio) for the serving channel in dB. Serving RSRQ displays the reference signal received quality for the serving channel in dB. Serving RSRP displays the reference signal received power for the serving channel in dBm. Serving PCI displays the physical channel identifier number for the serving channel. Neighbor RSRQ displays the reference signal received quality values for the neighbor channels in dB. Neighbor RSRP displays the reference signal received power values for the neighbor channels in dBm. Neighbor PCI displays the physical channel identifier numbers for neighboring channels.
N E MO HA N DY -A VIE W S
105
PDSCH BLER displays the block error rate for the PDSCH (physical downlink shared channel) in percentage. PDSCH Throughput displays the downlink data throughput for the PDSCH in bps. PDSCH Rank 2 Percentage displays the percentage of TTIs (transmission time intervals, 1ms) during the reporting period where Rank 2 (MIMO 2x2) has been used in PDSCH channel. PDSCH Modulation Codeword 0 displays the PDSCH modulation for codeword 0. This is the modulation order as defined by 3GPP TS 36.213 subclause 7.1.7. The available values are 1 = QPSK 2 = 16QAM 3 = 64QAM
PDSCH Modulation Codeword 1 displays the PDSCH modulation for codeword 1. This is the modulation order as defined by 3GPP TS 36.213 subclause 7.1.7. PDSCH MCS Codeword 0 displays the PDSCH MCS index for codeword 0. The value defines the modulation and the amount of coding used. See 3GPP TS 36.213 subclause 7.1.7. Values range from 0 to 31. PDSCH MCS Codeword 1 displays the PDSCH MCS index for codeword 1. The value defines the modulation and the amount of coding used. See 3GPP TS 36.213 subclause 7.1.7. Values range from 0 to 31. PDSCH PRB Allocation displays the number of allocated physical resource blocks for the PDSCH.
106
N e mo Han d y-A U s e r Ma nu al
TX Power PUSCH displays the TX power level for the PUSCH (physical uplink shared channel) in dBm. Values range from 30 to -120. TX Power PUCCH displays the TX power level for the PUCCH (physical uplink control channel) in dBm. Values range from 30 to -120. PUSCH Throughput displays the uplink data throughput for the PUSCH in bps. PUSCH Modulation displays the PUSCH modulation for codeword 0. This is the modulation order as defined by 3GPP TS 36.213 subclause 7.1.7. PUSCH Rank defines how many data streams are used for the data transmission. The value of the parameter is zero when data is not transmitted. Possible values are 0 and 1. PUSCH MCS Modulation displays the PUSCH MCS index for codeword 0. The value defines the modulation and the amount of coding used. See 3GPP TS 36.213 subclause 7.1.7. Values range from 0 to 31. Timing Advance displays the timing advance value for the serving channel. Timing advance is used to adjust uplink transmission timing in a way that allows node B to receive transmissions from all UEs simultaneously. Values range from 0 to 1282. RACH Type displays the RACH message type. The possible values are contention based and noncontention based. RACH Result displays the RACH message result. The possible values are succeeded, aborted, and failed. RACH Maximum Allowed Preambles displays the maximum allowed number of RACH preambles. See 3GPP 136.133 subclause 6.3.2 and 3GPP 136.321 subclause 5.1. Values range from 3 to 200. RACH Number of Trans. Preambles displays the number of preambles that were sent during the RACH procedure. Cyclic Prefix defines the type of signal the terminal is set to measure. With Autodetect selected, the terminal will automatically detect the appropriate signal type.
N E MO HA N DY -A VIE W S
107
The cell measurements view 1/2 (the neighbor view) displays the PCI (physical channel identifier) and RSRQ (reference signal received quality) and RSRP (reference signal received power) for the serving and neighbor channels. The serving channel is displayed first on the list (in black).
The cell measurements view 2/2 displays the Channel number, PCI (physical channel identifier), RSRQ (reference signal received quality), and RSRP (reference signal received power) for the serving (first on list) and neighbor channels.
108
N e mo Han d y-A U s e r Ma nu al
PDSCH Throughput displays the downlink data throughput for the PDSCH in bps. Serving SNR displays the SNR (signal to noise ratio) for the serving channel in dB. PDSCH PRB Allocation displays the number of allocated physical resource blocks for the PDSCH.
PDSCH Throughput displays the downlink data throughput for the PDSCH in bps. App. Throughput Downlink/Uplink displays the data throughput rate in downlink and in uplink direction. Serving SNR displays the SNR (signal to noise ratio) for the serving channel in dB. PDSCH PRB Allocation displays the number of allocated physical resource blocks for the PDSCH.
N E MO HA N DY -A VIE W S
109
PDSCH Rank 2 Percentage displays the percentage of TTIs (transmission time intervals, 1ms) during the reporting period where Rank 2 (MIMO 2x2) has been used in PDSCH channel. PDSCH PRB Allocation displays the number of allocated physical resource blocks for the PDSCH. CQI Wideband Codeword 0 displays the wideband channel quality indicator value for codeword 0. This is the average wideband CQI calculated over the reporting period. See 3GPP TS 36.213 subclause 7.2. Values range from 0 to 15. CQI Wideband Codeword 1 displays the wideband channel quality indicator value for codeword 1. This is the average wideband CQI calculated over the reporting period. See 3GPP TS 36.213 subclause 7.2. Values range from 0 to 15.
Table 1. displays the relative ratio of downlink QSPK, 16QAM and 64QAM modulation activity for codeword 0. Table 2. displays the relative ratio of downlink QSPK, 16QAM and 64QAM modulation activity for codeword 1.
110
N e mo Han d y-A U s e r Ma nu al
PUSCH Throughput displays the uplink data throughput for the PUSCH in bps. PUSCH PRB Allocation displays the number of allocated physical resource blocks for the PUSCH.
The uplink modulation ratio displays the relative ratio of uplink QSPK, 16QAM and 64QAM modulation activity for codeword 0.
N E MO HA N DY -A VIE W S
111
App. Throughput displays the data throughput rate in downlink and in uplink direction. PCI displays the serving physical channel identifier number. Serving RSRP displays the reference signal received power of the serving channel in dBm. TX Power PUCCH displays the TX power level for the PUCCH (physical uplink control channel) in dBm. Values range from 30 to -120.
Views 3/8 and 4/8 display the application throughput in downlink and in uplink direction in kb per second.
112
N e mo Han d y-A U s e r Ma nu al
The gauge view displays the application throughput in downlink and in uplink direction in kb per second and the amount of data transferred in downlink and in uplink direction in bytes.
PPP Throughput views display the downlink and uplink throughput values in kbps. The value is calculated based on the SDUs (service data units) that are successfully transferred through the PPP layer. Missing and erroneous PPP packets are excluded from the throughput calculation.
N E MO HA N DY -A VIE W S
113
App. Throughput DL displays the application throughput in downlink direction in kb per second. iPerf PER DL displays the downlink packet error rate, i.e., the percentage of erroneously transferred packets
from the total number of transferred packets.
iPerf Jitter DL displays the packet jitter downlink in ms. App. Throughput UL displays the application throughput in uplink direction in kb per second. iPerf PER UL displays the uplink packet error rate, i.e., the percentage of erroneously transferred packets
from the total number of transferred packets.
App. Throughput DL displays the application throughput in downlink direction in kb per second. YouTube Buffer displays the percentage of the video loaded in the buffer. YouTube Play State displays the current state of the video streaming.
114
N e mo Han d y-A U s e r Ma nu al
System displays the current cellular system, e.g., CDMA2000 1900. Packet technology displays the current packet technology, e.g., 1xEVDO REV B MCC displays the mobile country code. Channel type displays the current channel type. System ID displays the system ID. Network ID displays the network ID. Active pilot number displays the active pilot number(s). Active Ec/I0 displays the Ec/I0 value for the active pilot(s). Active RSCP displays the RSCP value for the active pilot(s). Channel number displays the current channel number. RX power 0/1 displays the RX power for antennas 0 and 1. The values range from 120 to 30 dBm. TX power displays the TX power. Values range from 99 to 99 dBm. Frame error rate displays the frame error rate in percentage. Downlink/uplink power up % displays the percentage of "DL/UL power up" commands out of all commands. If this value is 100%, all commands request to increase power. RLP downlink/uplink throughput displays the DL/UL user throughput in radio link protocol layer.
N E MO HA N DY -A VIE W S
115
The Cell measurements view displays the pilot number and Ec/I0 for the serving (first on list) and neighbor pilots.
The Cell measurements 2/2 view displays the Channel number, PN, Ec/I0, and RSCP for the serving (first on list) and neighbor channels.
116
N e mo Han d y-A U s e r Ma nu al
The Power control line view displays the TX power and FER (for CDMA).
Downlink/uplink power up % displays the percentage of "DL/UL power up" commands out of all commands. If this value is 100%, all commands request to increase power.
N E MO HA N DY -A VIE W S
117
The RX power line view displays the RX power for antennas 0 and 1. The values range from 120 to 30 dBm.
118
N e mo Han d y-A U s e r Ma nu al
SETTINGS
The chapters below describe the Settings pages.
GENERAL SETTINGS
In Nemo Handy-A, select Menu | Settings | General to define some general settings.
Automated testing option activates/deactivates the automated testing feature. See Automated Testing for more information. Backlight option defines the brightness of the backlight. Fullscreen, when selected, hides the Android status bar on the top of the screen. Screenshot format defines in which format (.pgn or .jpg) the captured screenshot will be saved. Screenshot timestamp, if selected, leaves a timestamp on the captured screenshot. Screenshot all views, if selected, captures a screenshot of all views. Ask, when selected, prompts Nemo Handy-A to ask whether to take screenshot of all views whenever the user is taking a screenshot. For CDMA/LTE devices, you will see the Measurement mode item. Select CDMA only to make only voice calls. Select LTE/EVDO data to make data measurements. Answer incoming calls option activates/deactivates the auto answer mode. When Nemo Handy-A is in auto answer mode, it answers all incoming voice calls. Select Menu | Settings | General | Answer incoming calls to activate/deactivate the mode. Active WiFi scanning activates/deactivates WiFi scanning.
SE T T IN G S
119
DISPLAY SETTINGS
In Nemo Handy-A, select Menu | Settings | Display to define the display settings.
Display config file defines which views are displayed. Default and Default extended are the two default configurations. Units defines the measurement units used when defining the Nemo Handy-A maps (Metric/Imperial). Show serving info displays/hides the serving channel information on every page. Show web view displays/hides the web view. Show YouTube view displays/hides the YouTube view. Note that the web view and YouTube view functionalities are available only if your Nemo Handy-A license supports them. Notification volume sets the volume level for voice notifications. Notifications enables you to select which notification icons and/or notification audio files are in use. See chapter Notifications for more information on notifications. Show notification page setting displays/hides the Notification History view.
120
N e mo Han d y-A U s e r Ma nu al
WCDMA/LTE signaling messages defines which WCDMA/LTE signaling message headers are displayed in Nemo Handy. Signaling messages view (second page under Radio Parameters) displays a list of the selected signaling messages. Lock the view by tapping the lock icon and tap an individual message to view the timestamp for that message.
CDMA/EVDO signaling messages defines which CDMA/EVDO signaling message headers are displayed in Nemo Handy. Signaling messages view (second page under Radio Parameters) displays a list of the selected signaling messages. Lock the view by tapping the lock icon and tap an individual message to view the timestamp for that message.
SE T T IN G S
121
Notifications
Select Settings | Display | Notifications to access the Notifications page. Here you can activate/deactivate, edit existing, and create new notifications. See chapter Custom Notifications for more information on editing and creating new notifications. There are two types of notifications: audio and icon. Audio notifications will play an audio file when triggered. Notifications with icons will appear as icons on the measurement route on a map and in line graphs. A popup message can be selected for both types of notifications. The popup appears briefly at the bottom of the screen.
With the buttons at the top you can select/clear all icons, audio files, and popups. By tapping each parameter, you can select individual notifications. By tapping the speaker icon, you can preview the audio file. Notification Best RSCP Low Best Ec/N0 Low Tx Power High BLER High RX Level Low RX Quality Bad Trigger Active set received signal code power under -95 Active set Ec/N0 under -15 TX power over 14 Block error rate downlink over 5 RX level under -95 RX quality over 4
122
N e mo Han d y-A U s e r Ma nu al
C/I under 12 Percentage of downlink power up commands over 60 Percentage of uplink power up commands over 60
Custom Notifications
It is possible to edit existing notifications and also create new notifications. To edit a notification, tap the button next to a notification.
Trigger defines the condition for the notification. The options are Change, Equals threshold, Over threshold, and Under threshold. Threshold defines the value that triggers the notification. This setting is hidden when the Change trigger option is selected. Hysteresis defines a tolerance value for triggering the notification. Value 0 means hysteresis is not used. This setting is hidden when the Change trigger option is selected. Default action defines how you will be notified. The options are audio, icon, or popup. You can also select all three.
SE T T IN G S
123
To create a new notification, tap the New notification button at the top of the Notifications page.
Label defines the name of the notification. Parameter name defines the parameter or measurement event for which the notification is created. Trigger defines the condition for the notification. The options are Change, Equals threshold, Over threshold, and Under threshold. Threshold defines the value that triggers the notification. This setting is hidden when the Change trigger option is selected. Hysteresis defines a tolerance value for triggering the notification. Value 0 means hysteresis is not used. This setting is hidden when the Change trigger option is selected. Speak defines the audio (text to speech) used in connection with the notification. Type in the text and it will be played when the notification is triggered. Icon defines the appearance of the notification icon (circle, square, triangle). Also select the color. Default action defines how you will be notified. The options are audio, icon, or popup. You can also select all three. After defining all the settings, tap Save and the new/edited notification is added to the list.
124
N e mo Han d y-A U s e r Ma nu al
LOGGING SETTINGS
In Nemo Handy-A, select Menu | Settings | Logging to define the logging settings.
Log file prefix allows you to define your own prefix for log file name. If the Autologging option is selected, Nemo Handy-A will start logging when a script is started and stop logging when the script is finished. It is also possible to switch autologging off in the middle of a script if you would like to continue logging even after the script is finished. Log file splitting option allows you to split the log files into manageable sized files instead of having one large file. See Log File Splitting for more information. IP capture option activates/deactivates IP packet capturing. See IP Capture for more information on IP capturing. Measurement uploading allows you to save connection settings into configurations that can be used when uploading files on a server. See Defining Measurement Upload Configurations for more information.
SE T T IN G S
125
If you select the Fixed file size limit option, you can define a file size in MB after which the file will be saved and a new file created. With the fixed option, the ongoing script round (repeat) is interrupted when the limit is reached, a new file is created, and the ongoing script round is started from the beginning. Please note that if you define a very small file size and select the fixed file size limit option, there is a possibility that the script will loop indefinitely. In such a case, adjust the file size limit big enough for the script to finish.
If you select the Flexible file length limit option, you can define a file length in minutes after which the file will be saved and a new file created. With the flexible option, the ongoing script will not be interrupted when the limit is reached. Instead, logging will continue until the current script round (repeat) is finished, and a new file is created when the next script round is started.
126
N e mo Han d y-A U s e r Ma nu al
If you select the Fixed file length limit option, you can define the file length in minutes after which the file will be saved and a new file created. With the fixed option, the ongoing script round (repeat) is interrupted when the limit is reached, a new file is created, and the ongoing script round is started from the beginning. Please note that if you define a very short file length and select the fixed file length limit option, there is a possibility that the script will loop indefinitely. In such a case, adjust the file length limit long enough for the script to finish.
You can also limit the number of log files saved. Select the Limit number of files saved option and define a number in the Max number of complete files saved field. If there are more files than the number that you selected, only the most recent files are saved. Furthermore, if there is an incomplete file (e.g., logging is stopped manually in the middle of a script), those are saved as well in addition to the complete files.
SE T T IN G S
127
128
N e mo Han d y-A U s e r Ma nu al
On the Create configuration page define settings needed for the file upload. Once you have defined all settings, tap Save. The configuration will appear on the Select Configuration page. Note that the contents vary slightly depending on the selected protocol.
Target folder path defines the target location for the uploaded files when FTP protocol is used. Type in the path and tap Verify Path and the target folder path will be checked. If you want to create a new target folder on the FTP server, type in the name in the Target folder path field (e.g. /handy) and tap the Create and Verify button. If the path is correct, a Path verification successful message is displayed. URL defines the target path for the uploaded files when HTTP or HTTPS protocol is used. Type in the address and tap Verify URL and the target path will be checked. If the path is correct, a Verification successful message is displayed. Prefix type defines a prefix that will be added at the beginning of the file name. Select None and no prefix will be added and IMEI will add the terminals IMEI code. You can also type in a custom prefix.
SE T T IN G S
129
Selected FTP/HTTP/HTTPS connection defines the connection used for the file upload. To select a premade connection, tap Select, select a connection from the list and tap Select. To create a new connection, tap Select on the Create configuration page and then tap Create New.
Host defines the FTP host address. Port defines the host port. Passive mode option defines whether passive mode is used or not. Username defines the host site logon user name
130
N e mo Han d y-A U s e r Ma nu al
Password defines the host site logon password. After defining all settings, tap the Verify Connection button to check that the settings are correct. You should see the Verification successful message. After the connection has been verified, tap Save to save the connection for future use. The saved connection will be added on the Select FTP connection page. You can access the Select FTP connection page also through the script editor when defining FTP logon settings and when defining settings for manual FTP transfers.
Host defines the host IP address. Username defines the host site logon user name Password defines the host site logon password. Select the Authenticate server option (for HTTPS) to authenticate the HTTPS server. After defining all settings, tap the Verify Connection button to check that the settings are correct. You should see the Verification successful message. After the connection has been verified, tap Save to save the connection for future use.
SE T T IN G S
131
GPS SETTINGS
Show GPS view displays/hides the GPS view. When Use GPS time option is selected, the system clock is synchronized with GPS time at the beginning of a measurement. Logging is not started before there is a GPS fix and the clock can be synchronized. If logging is started and there is no GPS fix, Nemo Handy will go into "Waiting state" during which Nemo Handy cannot be used. Please note that this option affects the system clock in Nemo Handy. Not the clock in the Android terminal. GPS source defines the GPS source (No GPS/Internal GPS/External GPS) Bluetooth devices displays the enabled devices.
132
N e mo Han d y-A U s e r Ma nu al
Show indoor map defines whether the map is displayed (On) or not (Off). Draw route defines whether the markers placed on the map are connected to draw the measurement route (On) or not (Off).
Select the Show notifications on map option to display notification icons on the measurement route.
Route line width setting defines the width of the route line displayed on the map. Route color defines the color displaying the route on the map.
Indicate parameter on route color, when set to Yes, enables you to observe the values of certain network parameters from the route coloring on the map. Which color refers to which parameter is predefined. Route parameter (effective when indicating parameter) defines which parameter is used in coloring the indoor route. Indoor route coloring is based on the selected parameter's values, and user-defined or pre-defined limits and color sets. Floorplans displays a list of .tab files that have been loaded in Nemo Handy-A. See Importing Maps and Defining Map Settings. Import iBwave maps allows you to import iBwave map files (see Importing iBwave Maps for more information).
SE T T IN G S
133
Show outdoor map (Yes/No) defines whether the map is displayed (On) or not (Off). Show notifications on map (Yes/No) defines whether notifications appear on the map. Draw route defines when the measurement route is drawn on the map. The alternatives are always, when logging, and never. Route autoreset (Yes/No), defines whether logging starts and stops drawing the route. Route line width defines the width of the route line on the scale from 1-20. Route color defines the color displaying the route on the map.
Indicate parameter on route color, when set to Yes, enables you to observe the values of certain network parameters from the route coloring on the map. Which color refers to which parameter is predefined. Show BTS defines whether BTS icons are displayed on the outdoor map. Also select a BTS file on the BTS settings page. Active cell color defines the color for the serving cell when a BTS file is used.
134
N e mo Han d y-A U s e r Ma nu al
Active system color defines the color for serving system base stations when a BTS file is used. For example, if the device is connected to a WCDMA network, all WCDMA base stations are colored with the selected color.
Other system color defines the color for the non-serving system base stations when a BTS file is used. For example, if the device is connected to a WCDMA network, all other base stations are colored with the selected color. Map whitening percentage enables the user to define the map whitening percentage to highlight the contrast. Map repository enables the user to select from which map repository the outdoor map is downloaded from. HTTP map loading, defines when Handy-A is allowed to load a map (Always/When not logging/Never)
SE T T IN G S
135
BTS SETTINGS
Show BTS view displays/hides the BTS view. The BTS view displays information about the current BTS file. BTS file defines the BTS file displayed on the outdoor map. Select Yes in the Use BTS file in order to view the BTS icons on the outdoor map. Cell info allows you to display selected cell information on a map. First select a BTS file and then select Yes in the Use BTS file option. Select the information you would like to view on a map. See chapter BTS Information on a Map for more information.
136
N e mo Han d y-A U s e r Ma nu al
UI CUSTOMIZATION SETTINGS
Through the UI Customization page you can select parameters to be displayed on a map and in the serving info parameter bar.
Map parameters allows you to select parameters to be displayed on a map. You can also define a color set for the parameters. Serving info parameters allows you to select parameters to be displayed in the serving info bar that can be displayed at the top of the screen (select Settings | Display | Show serving info). Tap the Serving info parameters item to select and edit the parameters.
SE T T IN G S
137
Select a parameter from the list by tapping the check mark. If you wish to edit the properties of the parameter, tap the Settings button.
You can edit the appearance of the parameter in the serving info bar and define for which technologies the parameters is displayed. Finally tap Save.
Label refers to the parameter name displayed in the serving info bar. Format defines the format in which the value is displayed. The options are decimal, hexadecimal, and octadecimal. Show unit defines whether the parameter value unit is displayed in the serving info bar. System defines for which network technologies the parameter is displayed. Note that the width of the serving info bar is limited so all of the selected parameters may not fit in the bar. Turning the terminal horizontally will make the serving info bar wider and more parameters will fit in.
138
N e mo Han d y-A U s e r Ma nu al
Voice quality mode defines the voice quality mode. The options are off, downlink, and uplink+downlink. Uplink+downlink: Sample is sent and received in turns. The downlink voice quality is measured by the Nemo Handy-A terminal and uplink quality by Nemo Server or another Nemo Handy-A terminal. Downlink: Sample is only received. Downlink mode requires Nemo Server in playback mode to which voice calls are made.
Sample file defines the voice sample file used in the voice quality testing. There are two types of samples: wideband and narrowband. If the sample filename has a wb postfix, the sample is wideband. Otherwise it is narrowband.
SE T T IN G S
139
POLQA measurements can be done in Super Wideband (SWB) or in Narrowband (NB) mode. The mode is selected automatically based on the sample, that is, if a wb sample is selected, SWB POLQA measurement mode will be used. Respectively, if NB sample file is selected, NB POLQA measurement mode will be used. Note that SWB POLQA measurement mode should be only used with voice calls where WB AMR codecs are used. WB AMR is only used in mobile-to-mobile voice calls where in both ends the mobile is WB AMR capable, and the WB AMR codec is enabled in the network. Note that SWB POLQA cannot be used when testing against a fixed line, for example, between Nemo Handy-A and Nemo Server. MOS threshold can be used to limit the number of samples saved to the measurement file. For example, only samples with a MOS score below 3 are saved. Automatic level alignment scales both input signals to an average active speech level of approximately -26dBov. Uplink volume sets the uplink volume level. Please note that in most cases the default value is recommended.
140
N e mo Han d y-A U s e r Ma nu al
ENDING MEASUREMENTS
To end the measurements:
1. Stop all calls and data connections. 2. Select Menu | Stop logging. Nemo Handy-A will stop the recording. You are able to keep, rename or delete the resulting log file. If you wish to upload the log file, indoor map file, or a packet capture file on a server, select the respective options and tap Save. See Uploading Log files on Server for more information on the connection settings.
E XPOR T IN G A N D C ON VE R T IN G FILE S
141
Select one of the existing configurations and tap Select. For more information on creating new configurations, see Defining Measurement Upload Configurations. After the files have been uploaded, Nemo Handy-A will ask if you would like to send a notification of the uploaded files. You can send an email or an SMS. In order to send an email, you need to have an email account set up on your mobile. The notification contains a link to the server from where the files can be downloaded. Tap the Delete Sent Files button to delete the uploaded files from the Nemo Handy-A terminal.
142
N e mo Han d y-A U s e r Ma nu al
Status displays the current status of the File Manager. Bluetooth connection displays Bluetooth connection settings.
E XPOR T IN G A N D C ON VE R T IN G FILE S
143
In the Rule Settings dialog, click Add File to browse to the appropriate folder, select the file(s), and click OK or click Add Folder to select a whole folder. The selected file appears in the New Source Items view. Settings defines different settings for handling the files. File extension filtering makes it possible for you to define which file extension will be used in the conversion rule. Uncompress archive files enables you to uncompress zipped archive files. Convert .nbl files allows you to choose files with .nbl endings to be converted. Conversion Timing enables you to schedule all conversion operations to occur only during specific hours of the day. No timing disables Conversion Timing. Conversion timed between defines a time range during which conversion operations are allowed to be performed. Source File Actions defines how the source files are handled after they have been converted.
144
N e mo Han d y-A U s e r Ma nu al
None leaves the source file in the original folder but adds the extension processed in the file name. Delete deletes the source file after conversion. Move to folder moves the source file to a selected folder after conversion. Click the Browse button to select a folder. Archive to folder moves and compresses the source file to a selected folder after conversion. Click the Browse button to select a folder. Use source folder as destination folder, when selected, enables the source folder to act as an destination folder Destination folder defines a location for the converted files. Click the Browse button to select a folder. The Embed indoor marker coordinates option in the Conversion options field allows you to embed marker coordinates from a separate .mrk file to the .nmf file that is created with the File manager. This allows the user, for example, to export indoor measurement files to MapInfo files without losing the coordinates. After you have added all the files and folders, click OK to start the conversion process. When the conversion is finished, the Status column will display Finished. The converted file will be in the selected destination folder with the same file name but with a new extension.
T IPS A N D HIN T S
145
POST-PROCESSING MEASUREMENTS
POST-PROCESSING WITH NEMO OUTDOOR
Before you can open a Nemo Handy-A measurement file in Nemo Outdoor, you must convert the file to Nemo File Format using the Nemo File Manager (see Converting Measurement Files to Nemo File Format). After the conversion, you can open the measurement file in Nemo Outdoor. Please refer to the Nemo Outdoor manual for further instructions.
146
N e mo Han d y-A U s e r Ma nu al
STARTING MEASUREMENTS
Before you start logging with Nemo Handy-A, please check that the mobile is in idle mode, i.e., there are no data connections or calls ongoing. If there is a call on when you start logging, it will affect the measurement events logged and you will not have the signaling at the beginning of the log file.
FILE LOCATIONS
The various files associated with Nemo Handy-A have specific file locations. When adding files to Nemo Handy-A, you should only use these specified folder locations for the files. Measurement data files are saved to sdcard/Nemo/Handy/Results folder on the memory card of your Nemo Handy-A terminal by using e.g. a Bluetooth connection, a cable connection, or a memory card reader. The following are the file locations where Nemo Handy-A related files should be saved. Measurement data (.nbl) sdcard/Nemo/Handy/Results Display configurations (.xml) Display configurations are installed to the "/sdcard/Nemo/Handy/Config" directory.
N E MO HA N DY SU PPOR T
147
ONLINE HELP
You will find an online help in Nemo Handy. Select Menu | More | Help to open the help file.
INTERNET SUPPORT
At our web site http://www.anite.com/nemo, you can find all the frequently asked questions about Nemo Handy-A, among other information.
USER CLUB
The Nemo User Club offers several new ways to benefit from Nemo products. You can find it at our WWW site http://www.anite.com/nemo. Access to the Nemo User Club is restricted to customers with SW maintenance and Technical Support agreements or partner agreements. If you are an existing Nemo customer with SW maintenance and Technical Support agreements, but you are without access to the user club, please complete an online registration form. After submitting the requested information, you will receive a personal access key and password by email in a few days time. Once you are registered with our User Club, you will automatically receive e-mails letting you know each time a new version of software for your Nemo Product is released. It is fast, easy, and it is available to you seven days a week, 24 hours a day. If you have questions relating to the Nemo User Club, please e-mail us at nemosupport@anite.com.
148
N e mo Han d y-A U s e r Ma nu al
Global E-mail Tel. Fax Address nemosupport@anite.com +358 50 395 7800 +358 8 551 6182 Anite Finland Ltd Kiviharjunlenkki 1 D 90220 Oulu Finland
Americas E-mail Mobile Fax Address nemosupport@anite.com +1 469 951 9106 +1 972 929 9898 Anite Inc. 6333 N. State Hwy 161 Suite 110 Irving, TX 75038 USA
APAC E-mail Tel. Fax Address nemosupport@anite.com +65 6254 9003 +65 6254 9885 Anite Singapore Pte Ltd 101 Thomson Road, #18-04 United Square Singapore 307591
P.R. China E-mail Tel. Fax nemosupport@anite.com +86 10 6567 8528 +86 10 6567 8521
N E MO HA N DY SU PPOR T
149
Address
Anite Wireless Trading (Beijing) Ltd JB11-0-092, Jianwai Diplomatic Compound, Jianguomenwai Street Chaoyang District Beijing 1000600,China
When contacting us for problem reporting, please supply/inform us of: Your Nemo Handy-A version and build, see Menu | About or Menu | More | About Your description of the problem Whether you were able to repeat the problem The corresponding measurement results file (as e-mail attachment or on disc)
150
N e mo Han d y-A U s e r Ma nu al
APPENDIX
END-USER LICENSE AGREEMENT
IMPORTANT - READ CAREFULLY: This End-User License Agreement ("EULA") is a legal agreement between you (either an individual or a single entity) and Anite Finland Ltd for the Anite Finland Ltd software product(s), in whatever form, identified above ("Software Product" or "Software"). The Software Product includes computer software, the associated media, any printed materials, and any "online" or electronic documentation. By installing, copying or otherwise using the Software Product, you agree to be bound by the terms of this EULA. If you do not agree to the terms of this EULA, Anite Finland Ltd is unwilling to license the Software Product to you. In such event, you may not use or copy the Software Product, and you should promptly return the unused product(s) in their original packaging to the place of purchase within thirty days of the date of original purchase. SOFTWARE PRODUCT LICENSE The Software Product is protected by copyright laws and international copyright treaties, as well as other intellectual property laws and treaties. The Software Product is licensed, not sold. 1. GRANT OF LICENSE. This EULA grants you the following rights: Software. You agree that the Software product is licensed to you to be used with the mobile phone(s) and software protection key designated by Anite Finland Ltd for such use ("Designated Hardware"). You also agree that you shall not have more than one copy of the Software Product in use at a time for any Designated Hardware in which the Software Product is to be used or to be distributed except as expressly provided for in this EULA. You may use one copy of the Software Product in binary code form only on one computer at a time in order to conduct system measurements using the Designated Hardware at various locations to the extent necessary for the permitted operation of the application software but may not duplicate the Software Product. Storage/Network/Single Use. You may also store or install a copy of the Software Product in binary code form only over an internal network, and distribute the Software Product to your other computers over an internal network. However, you must acquire and dedicate a license for the Software Product for each Designated Hardware on which the Software Product is used or to which it is distributed. A license for the Software Product may not be shared or used concurrently on different computers. 2. DESCRIPTION OF OTHER RIGHTS AND LIMITATIONS. Limitations on Reverse Engineering, Decompilation and Disassembly. Removal, emulation, or reverse engineering of all or any part of this product or its protection constitutes an unauthorized modification to the product and is specifically prohibited. Nothing in this license statement permits you to derive the source or assembly code of files provided to you in executable or object formats. Limitations on Modifications, Adaptations and Other Changes. You may not modify, adapt or otherwise make any changes to the Software Product except and only to the extent you are expressly permitted to do so under the applicable mandatory law notwithstanding this limitation or by Anite Finland Ltd's prior written consent. Separation of Components. The Software Product is licensed as a single product. Its component parts may not be separated for use on more than one Designated Hardware and computer as designated above.
A PPE N DIC E S
151
Not for Resale. This Software Product is Not for Resale" or "NFR" and your license only permits personal use and you may not sell or otherwise transfer the Software Product for value except as specified below. Rental. You may not rent, lease or lend the Software Product to any person or entity. Software Transfer. You may not otherwise give or permanently transfer any or all of your rights under this EULA without the express prior written consent of Anite Finland Ltd which such consent shall not be unreasonably withheld. Duration and Termination. This EULA is effective from the day you open the sealed media package or download and continues until termination. You may terminate this EULA at any time. Without prejudice to any other rights, Anite Finland Ltd may terminate this EULA if you fail to comply with the terms and conditions of this EULA. In either event, you must destroy all copies of the Software Product and all associated media, printed materials, updates and component parts and verify to Anite Finland Ltd in writing that such has been done. 3. SUPPORT SERVICES. Anite Finland Ltd may provide you with support services related to the Software Product ("Support Services"). Any supplemental software code provided to you as part of the Support Services shall be considered part of the Software Product and subject to the terms and conditions of this EULA. With respect to technical information you provide to Anite Finland Ltd as part of the Support Services, Anite Finland Ltd may use such information for its business purpose, including for product updates and development. 4. COPYRIGHT AND TRADEMARKS. All title and copyrights in and to the Software Product (including but not limited to any images, photographs, animations, video, audio, music, text and "applets", incorporated into the Software Product), the accompanying printed materials, and any copies of the Software Product, are owned by Anite Finland Ltd or its suppliers. The Software Product is protected by copyright laws and international treaty provisions. You may not copy the printed materials accompanying the Software Product. You may not remove, modify or alter any Anite Finland Ltd copyright or trademark from any part of the Software Product, including but not limited to any such notices contained in the physical and/or electronic media or documentation, in the Anite Finland Ltd Setup Wizard dialogue or 'about' boxes, in any of the runtime resources and/or in any web-presence or web-enabled notices, code or other embodiments originally contained in or dynamically or otherwise created by the Software Product. Portions based on WinWAP technology. Copyright Slob-Trot Software Oy Ab 2004. http://www.winwap.com Perceptual Objective Listening Quality Analysis (POLQA) according to ITU-T Recommendation P. 863 included in this product is protected by copyright and by European, US and other International patents and patent applications and isprovided under license from OPTICOM Dipl.-Ing. M. Keyhl GmbH, Erlangen, Germany, 2011 www.opticom.de POLQA is a registered trademark of OPTICOM GmbH. Used by permission. 2011 by the POLQA Coalition of OPTICOM GmbH, Germany - SwissQual AG, Switzerland - KPN, The Netherlands - TNO, The Netherlands. www.polqa.info
152
N e mo Han d y-A U s e r Ma nu al
5. DUAL-MEDIA SOFTWARE. You may receive the Software Product in more than one medium. Regardless of the type or size of medium you receive, you may use only that one medium that is appropriate for the systems you use to operate the Software Product. You may not use or install the other medium on any system. You may not loan, rent, lease or otherwise transfer the other medium to another user, except as part of the permanent transfer (as provided above) of the Software Product. 6. CONFIDENTIALITY AND NON-DISCLOSURE. You agree to keep in confidence and not to disclose in any manner or form to any third party nor publish any such data or information related to the Software Product. You agree to protect all information and data provided to you by Anite Finland Ltd related to the Software Product with the same degree of care that you use to protect your own like data and information, but with not less than that due care exercised by a reasonably prudent person under the same or similar circumstances. 7. U.S. GOVERNMENTAL RESTRICTED RIGHTS. The Software Product and documentation are provided with Restricted Rights. Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.277-7013 or subparagraphs (c)(1) and (2) of the Commercial Computer Software - Restricted Rights at 48 CFR 52-227-19, as applicable. 8. LIMITED WARRANTY. Anite Finland Ltd warrants that (a) the Software Product will perform substantially in accordance with the accompanying written materials for a period of three (3) months from the date of receipt, and (b) any third party hardware accompanying the Software Products will be free from defects in materials and workmanship under normal use and service for a period of one (1) year from the date of receipt. To the extent that implied warranties are disclaimable, they are disclaimed in paragraph 10. Some states/jurisdictions do not allow disclaimers of or limitations on duration of an implied warranty, so the above limitation may not apply to you. Any implied warranties on the Software Product and, as applicable, third party hardware that is not disclaimable are limited to three (3) months and one (1) year respectively. 9. CUSTOMER REMEDIES. Anite Finland Ltd and its suppliers' entire liability and your exclusive remedy shall be, at Anite Finland Ltd option, either (a) return of the price paid, or (b) repair or replacement of the software or hardware that does not meet the Limited Warranty contained in this EULA and which is returned to Anite Finland Ltd. The Limited Warranty contained herein is void if failure of the software or third party hardware has resulted from accident, abuse, misapplication or events beyond the control of Anite Finland Ltd including, but not limited to Acts of God, acts of nature or acts of war. Any replacement Software Products or hardware will be warranted for the remainder of the original warranty period or thirty (30) days, whichever is longer. Anite Finland Ltd is not responsible for ensuring adequate backup and storage for your data or records. 10. NO OTHER WARRANTIES. To the maximum extent permitted by applicable law, Anite Finland Ltd disclaims all other warranties, either express or implied, including but not limited to implied warranties of merchantability, fitness for a particular purpose, and non-infringement of third-party rights, with regard to the Software Product, the accompanying written materials, and any accompanying hardware. This limited warranty gives you specific legal rights. You may have others which vary from state/jurisdiction to state/jurisdiction.
A PPE N DIC E S
153
11. NO LIABILITY FOR CONSEQUENTIAL DAMAGES. To the maximum extent permitted by applicable law, in no event shall Anite Finland Ltd or its suppliers be liable for any damages whatsoever (including without limitation, special, incidental, consequential, punitive or indirect damages for personal injury, loss of business profits, business interruption, loss of business information, or any other pecuniary loss) arising out of the use of or inability to use this Software Product, even if Anite Finland Ltd has been advised of the possibility of such damages. In any case, Anite Finland Ltd and its suppliers' entire liability under any provision of this EULA shall be limited to the amount actually paid by you for the Software Product and/or third party hardware accompanying the Software Product. The Limitations of Liability contained in this Section apply to claims of every kind, whether based on contract law, tort law or otherwise, even if these limitations have the effect of exculpating a party from responsibility for its negligence, fault or other conduct. Because some states/jurisdictions do not allow the exclusion or limitation of liability for consequential or incidental damages, the above limitation may not apply to you.