0.1 ppm (insignicant level) sample-tosample carryover Accurate Results Fast Throughput up to 800 chemistry tests and 100 immunoassay tests per hour Immediate STAT processing Up to seven customizable priority bays Easy to Operate Intuitive software with a single interface Access to reagents, samples and supplies while system is in process Multiple tube types and sizes Expanded calibration and QC capabilities
* In development
1 4
1 2 3
4 5 6
Integrated Chip Technology (ICT) Refrigerated reagent carousel (90 positions, 50 55 assays) Reagent probes (2)
* In development
10
11
12
7 8
Customizable Priority Bays (0 7) with blue indicator lights Robotic Sample Handler (RSH) 180 samples
9 10 11 12
Reaction vessel hopper Reagent and sample pipettor Refrigerated reagent carousel (25 positions) RSH routine indicator lights
S I M P L I F I E D O P E R AT I O N . ROBUST SCIENCE.
Integration Without Compromise Abbott Diagnostics has combined seamless integration of immunoassay and clinical chemistry testing into one platform incorporating benets such as: Optimized workow: one tube for both IA and CC testing Prioritized samples with RSH Carryover control with SmartWash ( 0.1 ppm sample-to-sample carryover; level is insignicant)
ARCHITECT ci 4100*
RSH
* In development
ARCHITECT ci4100*
RSH
The unique design of the RSH on the ARCHITECT ci 4100 * meets the productivity demands of todays clinical laboratory.
Innovative design for access to reagents, samples and supplies while system is in process Universal sample carrier accepts 5, 7 and 10 mL tubes and sample cups without adapters Large capacity of 180 samples with ability to load 36 ve-position carriers
Priority bays allow for immediate STAT processing Priority samples automatically take precedence over routine ones Intuitive indicator lights allow sample and reagent status at a glance Automated management of retest, reex and dilution testing without operator intervention
ARCHITECT Universal Sample Carrier
1. Loading samples in priority bays initiates the RSH transport robot to lift urgent samples ahead of routine workload.
2. RSH design allows for continual sample access and fully automated reex testing and dilutions.
* In development
Abbott GmbH & Co. KG Abbott Diagnostics Max-Planck-Ring 2 65205 Wiesbaden, Germany Tel. (+49) 61 22 58 0 Fax (+49) 61 22 58 12 44 www.abbottdiagnostics.com
ARCHITECT, ci4100 and Put Science on Your Side are trademarks of Abbott Laboratories in various jurisdictions.
ARCHITECT c4000*
clinical chemistry Detection Methods Photometric Potentiometric Turbidimetric 800 tests/hour Serum, Plasma, Urine, CSF Height: 72 - 102 mm Diameter: 8.25 - 16.1 mm Yes (50 !L dead volume) 100 1.535 !L, Average: 5 !L Yes 0.1 parts per million or less Approximately 55 reagent kits onboard plus patented ICT (Na+, K+, and Cl-) >95% Liquid ready-to-use 565 days, Average: 30 days 160 days, Average: 25 days Yes Yes
ARCHITECT i1000SR
immunoassay CHEMIFLEX
ARCHITECT ci4100*
integration See c4000 and i1000SR specifications 900 tests/hour See c4000 and i1000SR specifications Height: 72 - 102 mm Diameter: 8.25 - 16.1 mm Yes (50 !L dead volume) 180 See c4000 and i1000SR specifications Yes 0.1 parts per million or less Approximately 80 reagent kits onboard plus patented ICT (Na+, K+, and Cl-) See c4000 and i1000SR specifications See c4000 and i1000SR specifications See c4000 and i1000SR specifications Yes Yes
Maximum Throughput Sample Types Sample Tubes Pediatric Sample Cup Sample Capacity Sample Volume Automatic Dilution Sample-to-Sample Carryover Reagent Capacity (Refrigerated)
100 tests/hour Serum, Plasma, Urine Height: 72 - 102 mm Diameter: 8.25 - 16.1 mm Yes (50 !L dead volume) 65 10150 !L, Average: 50 !L Yes 0.1 parts per million or less 25 reagent kits onboard
Reagent Type Reagent Onboard Stability Calibration Frequency Sample Clot and Bubble Detection Reagent Pressure Monitoring Sample Interference Measurement System Control Center Onboard Maintenance Logs Online Error Code Help Remote Diagnostics Dimensions (H x W x D) Weight Electrical Requirements Water Requirements Heat Output
Hemolysis, Icterus, and Lipemia measured on the c4000 A single computer with color touchscreen monitor, keyboard, and mouse Yes Yes AbbottLink 49.3" x 63.1" x 35.7" 1251 x 1602 x 907 mm 1132 lbs 513.5 kg AC 180-264V, 47-63 Hz, 20 Amp 15 L per hour during normal operation TBD BTU/hr, Average 7512 BTU/hr, Maximum Yes Yes AbbottLink 49.3" x 59" x 30" 1251 x 1499 x 762 mm 636 lbs 288 kg AC 99-127V, 47-63 Hz, 20 Amp or AC 180-264V, 47-63 Hz, 10 Amp As needed to dilute buffer concentrate 2113 BTU/hr, Average 5119 BTU/hr, Maximum Yes Yes AbbottLink 49.3" x 110.7" x 35.7" 1251 x 2812 x 907 mm 1677 lbs 760.7 kg See c4000 and i1000SR specifications See c4000 and i1000SR specifications See c4000 and i1000SR specifications