Stepper Motor and Its Driver

Reference of EAS 5407 Mechatronics Design Project

Spring 2003

I. Stepper Motor Basics


A stepper motor is an electro mechanical device, which converts electrical pulses into discrete mechanical movements. The shaft or spindle of a stepper motor rotates in discrete step increments when electrical command pulses are applied to it in the proper sequence. The sequence of the applied pulses is directly related to the direction of motor shafts rotation. The speed of the motor shafts rotation is directly related to the frequency of the input pulses and the length of rotation of input pulses applied. 1. Stepper Motor Advantages and Disadvantages Advantages 1. The rotation angle of the motor is proportional to the input pulse. 2. The motor has full torque at stand still (if the winding are energized) 3. Precise positioning and repeatability of movement since good stepper motor s have an accuracy of 3 5% of a step and this error is non cumulative from one step to the next. 4. Excellent response to starting stopping reversing. 5. Very reliable since there are no contact brushes in the motor. Therefore the life to the motor is simply dependant on the life of the bearing. 6. The motors response to digital input pulses provides open-loop control, making the motor simpler and less costly to control. 7. It is possible to achieve very low speed synchronous rotation with a load that is directly coupled to the shaft. 8. A wide range of rotational speed is proportional to the frequency of the input pulses. Disadvantages 1. Resonance can occur if not properly controlled. 2. Not easy to operate at extremely high speeds. 2. Open Loop Operation One of the most significant advantages of a stepper motor is its ability to be accurately controlled in an open loop system. Open loop control means no feedback information about position is needed. This type of control eliminates the need for expensive sensing and feedback devices such as optical encoders. Your position is known simply by keeping track of the input step pulses. 3. Stepper Motor Types There are three basic stepper motor types. They are: Variable-reluctance Permanent-magnet Hybrid

Variable-reluctance (VR) This type of stepper motor has been around for a long time. It is probably the easiest to understand from a structural point of view. Figure 1 shows a cross section of a typical V.R. stepper motor. This type of motor consists of a soft iron multi-toothed rotor and wound stator. When the stator windings are energized with DC current the poles become magnetized. Rotation occurs when the rotor teeth are attracted to energized stator poles. Permanent Magnet (PM) Often referred as a tin can or canstack motor the permanent magnet step motor is a low cost and low-resolution type motor with typical step angles of 7.50 to 150. PM motors as the name implies have permanent magnets added to the motor structure. The rotor no longer has teeth as with the VR motor. Instead the rotor is magnetized with alternating north and south poles situated in a straight line parallel to the rotor shaft. These magnetized motor poles provide increased magnetic flux intensity and because of this the PM motor exhibits improved torque characteristics when compared with the VR type.

Figure 1. Cross-section of a variable reluctance (VR) motor

Figure 2. Principle of a PM or tincan motor

Figure 3. Cross-section of a hybrid stepper motor

Figure 4. Principle of a disc magnet motor developed by Portescap

Hybrid (HB) The hybrid stepper motor is more expensive then the PM stepper motor but provides better performance with respect to step resolution, torque and speed. Typical step angles for the HB stepper motor range from 3.60 to 0.90. The hybrid stepper motor combines the best features of both the PM and VR type stepper motor. The rotor is multi-toothed like the VR motor and contains an axially magnetized concentric magnet around its shaft. The teeth on the rotor provide and even magnetic flux to preferred locations in the air gap. This further increases the detent, holding and dynamic torque characteristics of the motor when compared with both the VR and PM types. The two most commonly used types of stepper motors are the permanent magnet and the hybrid types. If a designer is not sure which type will best fit his applications requirements he should first evaluate the PM type as it normally several times less expensive. If not then the hybrid motor may be the right choice. There also exist some special stepper motor designs. One is the disc magnet motor. Here the motor is designed as a disc with rare earth magnets. This motor type has some advantages such as low inertia and a optimized magnetic flow path with no coupling between the two stator windings. These qualities are essential in some applications. 4. Size and Power In addition to being classified by their step angle stepper motors are also classified according to frame sizes which corresponding to the diameter of the body of the motor. For instance a size 11-stepper motor has a body diameter of approximately 1.1 inches. Likewise a size 23 stepper motor has a body diameter of 2.3 inches. The body length may however, vary from motor to motor within the same frame size classification. As a general rule the available torque output from a motor of particular frame size will increase with increased body length. Power levels for IC-driven stepper motors typically range from below a watt for very small motors up to 10-20 watts for larger motors. The maximum power dissipation level or thermal limits for the motor are seldom clearly stated in the motor manufactures data. To determine this we must apply the relationship P = V X I. For example, a size 23 step motor may be rated at 6V and 1A per phase. Therefore, with two phases energized the motor has a rated power dissipation of 12 watts. It is normal practice to rate a stepper motor at the power dissipation level where the motor case raises 650C above the ambient in still air. Therefore, if the motor can be mounted to a heat sink it is often possible to increase the allowable power dissipation level. This is important as the motor is designed to be and should be used at this maximum power dissipation, to be efficient from a size/output power/cost point of view.

5. When to use a Stepper Motor A stepper motor can be a good choice whenever controlled movement is required. They can be used to advantage in applications where you need to control rotation angle, speed, position and synchronism. Because of the inherent advantages listed previously, stepper motors have found their place in many different applications. Some of these include printers, plotters, high end office equipment, hard disk drives, medical equipment, fax machines, automotive and many more. 6. The Rotating Magnetic Field When a phase winding of a stepper motor is energized with current a magnetic flux is developed in the stator. The direction of this flux is determined by the Right Hand Rule which states: If the coil is grasped in the right hand with the fingers pointing in the direction of the current in the winding (the thumb is extended at a 900 angle to the fingers), then the thumb will point in the direction of the magnetic field. Figure 5 shows the magnetic flux path developed when phase B is energized with winding current in the direction shown. The rotor then aligns itself so that the flux opposition is minimized. In this case the motor would rotate clockwise so that its south pole aligns with the north pole of stator B at position 2 and its north pole aligns with the south pole of stator B at position 6. To get the motor to rotate we can now see that we must provide a sequence of energized the stator windings in such a fashion that provides a rotating magnetic flux field with the rotor follows due to magnetic attraction. 7. Torque Generation The torque produced by a stepper motor depends on several factors. The step rate The drive current in the windings The drive design or type In a stepper motor a torque is developed when the magnetic fluxes of the rotor and stator are displaced from each other. The stator is made up of high permeability magnetic material. The presence of this high permeability material causes the magnetic flux to be confined for the most part to the paths defined by the stator structure in the same fashion that currents are confined to the conductors of an electronic circuit. This serves to concentrate the flux at the stator poles. The torque output produced by the motor is proportional to the intensity of the magnetic flux generated when the winding is energized. The basic relationship which defines the intensity of the magnetic flux is defined by: H = ( N i ) 1 Where N = The number of winding turns i = current H = Magnetic field intensity

l = Magnetic flux path length

This relationship shows that the magnetic flux intensity and consequently the torque is proportional to the number of winding turns and the current and inversely proportional the lengths of the magnetic flux path. From this basic relationship one can see that the same frame size stepper motor could have very different torque output capabilities simply by changing the winding parameters. More detailed information on how the capability of the motor can be found in the application note entitled Drive Circuit Basics. 8. Phase, Poles and Stepping Angles Usually stepper motors have two phases, but three and five-phase motors also exist. A bipolar motor with two phases has one winding/phase and a unipolar motor has one winding, with a center tap per phase. Sometimes the unipolar stepper motor is referred to as a four-phase motor, even though it only has two phases. Motors that have two separate windings per phase also exist- these can be driven in either bipolar or unipolar mode. A pole can be defined as one of the regions in a magnetized body where the magnetic flux density is concentrated. Both the rotor and the stator of a step motor have poles. Figure 5 contains a simplified picture of a two-phase stepper motor having 2 poles for each phase on the stator and 2 poles on the rotor. In reality several more poles are added to both the rotor and stator structure in order to increase the number of steps per revolution of the motor, or in other words to provide a smaller basic stepping angle. The permanent magnet stepper motor contains an equal number of rotor and stator pole pairs. Typically the PM motor has 12 poles pairs. The stator has 12 pole pairs per phase. The hybrid type stepper motor has rotor with teeth. The rotor is split into two parts, separated by a permanent magnet- making half of the teeth south poles and half north poles. The number of pole pairs is equal to the number of teeth on one of the rotor halves. The stator of a hybrid motor also has teeth to build up a higher number of equivalent poles = 360/teeth pitch) compared to the main poles, on which the winding coils are wound. Usually 4 main poles are used for 3.6 hybrids and 8 for 1.8 and 0.9 degree types. It is the relationship between the number of rotor poles and the equivalent stator poles, and the number the number of phases that determines the full-step angle of a stepper motor. Step Angle = 360 ( N ph Ph) = 360 / N Nph = Number of equivalent poles per phase = number of rotor poles Ph = Number of phases N = Total number of poles for all phases together

If the rotor and stator tooth pitch is unequal, a more-complicated relationship exists.

Figure 5. Magnetic flux path through a two-pole stepper motor with a lag between the rotor and stator

Figure 6. Unipolar and bipolar wound stepper motors. 9. Stepping Modes The following are the most common drive modes. Wave Drive (1 phase on) Full Step Drive (2 phase on) Half Step Drive (1 + 2 phases on) Micro stepping (Continuously varying motor currents)

For the following discussions please refer to the figure 3. In Wave Drive only one winding is energized at any given time. The stator is energized according to sequence A B A B and the rotor steps from position 8 2 4 6 . For unipolar and bipolar wound motors with the same winding parameters this excitation mode would result in the same mechanical position. The disadvantage of this drive mode is that in the unipolar wound motor y9ou are only using 25% and in the bipolar motor only 50% of the total motor winding at any given time. This means that you are not getting the maximum torque output from the motor. In Full Step Drive you are energizing two phases at any given time. The stator is energized according to the sequence AB A B A B A B and the rotor steps from position 1 3 5 7 . Full step mode results in the same angular movement as 1 phase on drive but the mechanical position is offset by one half of a full step. The torque output of the unipolar wound motor is lower than the bipolar motor since the unipolar motor uses only 50% of the available winding while the bipolar motor uses the entire winding. Half Step Drive combines both wave and full step (1 & 2 phases on) drive modes. Every second step only one phase is energized and during the other steps one phase on each stator. The stator is energized according to the sequence AC B A B A A B B A B A and the rotor steps from position 1 2 3 4 5 6 7 8 . This results in angular movements that are half of those in 1 or 2 phases on drive modes. Half stepping can reduce a phenomena referred to as resonance which can be experienced in 1 or 2 phases on drive modes. The excitation sequences for the above drive modes are summarized in Table 1. In Micro stepping Drive the currents in the winding are continuously varying to be able to break up one full step into many smaller discrete steps. More information on micro stepping can be found in the micro stepping chapter. 10. Torque vs, Angle Characteristics The torque vs angle characteristics of a stepper motor are the relationship between the displacement of the rotor and the torque, which applied to the rotor shaft when the stepper motor is energized at its rated voltage. An ideal stepper motor has a sinusoidal torque vs displacement characteristic as shown in figure 7.

Figure 7. Torque vs. rotor angular position.

Figure 8. Torque vs. rotor angle position at different holding torque.

Table 1. Excitation sequences for different drive modes Position A and C represent stable equilibrium points when no external force or load is applied to the rotor shaft. When you apply an external force Ta to the motor shaft you in essence create an angular displacement, a . This angular displacement, a , is referred to as a lead or lag angle depending on whether the motor is actively accelerating or decelerating. When the rotor stops with an applied load it will come to rest at the position defined by this displacement angle. The motor develops a torque, Ta, in opposition to the applied external force in order to balance the load. As the load is increased the displacement angle also increases until it reaches the maximum holding torque, Th, of the motor. Once Th is exceeded the motor enters an unstable region. In this region a torque is the opposite direction is created and the rotor jumps over the unstable point to the next stable point. The displacement angle is determined by the following relationship: X = ( Z 2 ) sin(Ta Th ) where: Z = rotor tooth pitch Ta = Load torque Th = Motors rated holding torque X = Displacement angle.

Therefore if you have a problem with the step angle error of the loaded motor at rest you can improve this by changing the stiffness of the motor. This is done by increasing the holding torque of the motor. We can see this effect shown in figure 8. Increasing the holding torque for instant load causes a shift in the lag angle from Q2 to Q1. 11. Step Angle Accuracy One reason why the stepper motor has achieved such popularity as a positioning device is its accuracy and repeatability. Typically stepper motors will have a step angle accuracy of 3 5% of one step. This error is also non-cumulative from step to step. The accuracy of the stepper motor is mainly a function of the mechanical precision of its parts and assembly. Figure 9 shows a typical plot of the positional accuracy of a stepper motor. Step Position Error The maximum positive or negative position error caused when the motor has rotated one step from the previous holding position. Step position error = measured step angle theoretical angle Positional Error The motor is stepped N times from an initial position (N = 3600/step angle) and the angle from the initial position is measured at each step position. If the angle from the initial position to the N-step position is N and the error is N where: Q N = N ( step _ angle) N The positional error is the difference of the maximum and minimum but is usually expressed with sign. That is: positional error = 1 ( Max min ) 2 Hysteresis Positional Error The values obtained from the measurement of positional errors in both directions. 12. Mechanical Parameters, Load, Friction, Inertia The performance of a stepper motor system (driver and motor) is also highly dependent on the mechanical parameters of the load. The load is defined as what the motor drives. It is typically frictional, inertial or a combination of the two. Friction is the resistance to motion due to the unevenness of surfaces, which rub together. Friction is constant with velocity. A minimum torque level is required throughout the step in over to overcome this friction (at least equal to the friction). Increasing a frictional load lowers the top speed, lowers the acceleration and increases the positional error. The converse is true if the frictional load is lowered.

Figure 9. Positional accuracy of a stepper motor

Figure 10. Torque vs. speed characteristics of a stepper motor.

Inertia is the resistance to changes in speed. A high inertial load requires a high inertial starting torque and the same would apply for braking. Increasing an inertial load will increase speed stability, increase the amount of time it takes to reach a desired speed and decrease the maximum self-start pulse rate. The converse is again true if the inertia is decreased. The rotor oscillations of a stepper motor will vary with the amount of friction and inertial load. Because of this relationship unwanted rotor oscillations can be reduced by mechanical damping means however it is more often simpler to reduce these unwanted oscillations by electrical damping methods such as switch from full step drive to half step drive. 13. Torque vs Speed Characteristics The torque vs speed characteristics are the key to selecting the right motor and drive method for specific application. These characteristics are dependent upon (change with) the motor, excitation mode and type driver or drive method. A typical speed-torque curve is shown in figure 10.

Figure 11. Single step response time

To get a better understanding of this curve it is useful to define the different aspect of this curve. Holding torque The maximum torque produced by the motor at standstill. Pull-In Curve The pull-in-curve defines a area referred to as the start and stop region. This is the maximum frequency at which the motors can start/stop instantaneously, with a load applied, without loss of synchronism. Maximum Start Rate The maximum starting step frequency with no load applied. Pull-Out Curve The pull-out curve defines the area referred to as the slew region. IT defines the maximum frequency at which the motor can operate without losing synchronism. Since this region is outside the pull-in area the motor must ramped (accelerated or decelerated) into the region. Maximum Slew Rate The maximum operating frequency of the motor with no load applied. The pull-in characteristic varies also depending on the load. The larger the load inertia the smaller the pull-in area. We can see from the shape of the curve that the step rate affects the torque output capability of stepper motor the decreasing torque output as the speed increases is caused by the fact that at high speeds the inductance of the motor is dominant circuit element. The shape of the speed-torque curve can change quite dramatically depending on the type of driver used. The bipolar chopper type of driver used. The bipolar chopper type drivers, which Ericsson Components produces, will maximum the speed torque performance from a given motor. Most motor manufactures provide this speed torque curves for their motors. It is important to understand what driver type of drive method the motor manufacturer used in developing their curves as the torque vs speed characteristic of an given motor can vary significantly depending on the drive method used. 14. Single Step Response and Resonance The signal-step response characteristics of a stepper motor are shown in figure 10.

When one-step pulse is applied to a stepper motor the rotor behaves in manner as defined by the above curve. The step time is the time it takes the motor shaft to rotate one-step angle once the first step pulse is applied. This step time is highly dependent on the ratio of torque to inertia (load) as well as the type of driver used. Since the torque is a function of the displacement it follows that the acceleration will also be. Therefore, when moving in large step increments a high torque is developed and consequently a high acceleration. This can cause overshot and ringing as shown. The settling time T is the time it takes these oscillations or ringing to cease. In certain applications this behavior by micro stepping the stepper motor. For more information on micro stepping please consult the micro stepping note. Stepper motors can often exhibit a phenomena referred to as resonance at certain step rates. This can be seen as a sudden loss or drop in torque a certain speeds or low of synchronism. It occurs when the input step pulse rate coincides with the natural oscillation frequency of the rotor. Often there is a resonance area around the 100 200 pps region and also one in the high step pulse rate region. The resonance phenomenon of a stepper motor comes from its basic construction and therefore it is not possible to eliminate it completely. It is also dependent upon the load conditions. It can be reduced by driving the motor in half or micro stepping modes.

II. Stepper Motor and Driver Selection


Stepper motors are used in many different types of applications this makes it difficult to recommend a general step-by-step design flow chart. The design process is more an iterative process, involving experimentation. The purpose of this application note is to show how system performance is affected by motor and driver selection. Some popular motor and drivers are dealt with, as well as the importance of the gearing between the motor and the load. 1. Limits to system performance Torque and output power The output torque and power form a stepper motor are functions of motor size, motor heat sinking, working duty cycle, motor winding, and the type of driver used. In applications with low damping, the usable torque from the stepper motor can be drastically reduced by resonance. In data sheets for stepper motors, the pull-in and pull-out torque are given, as functions of stepping rate, for different types of motor and driver combinations. The pull-in torque curve shows the maximum friction torque with which, the motor can start, at different stepping rates, without losing any step. In an actual application, this curve ahs to be modified to account for the load inertia. The pull-out curve is of more interest, because it shows the total available torque when the motor runs at constant speed at a given frequency. In an application, this torque is used for overcoming the load friction torque and for accelerating the load and motor inertia. One problem when selecting the right motor type and size is the big influence that the driver has on the output torque and power. The difference in output torque, power, and system efficiency for a 7.5 degree 57 mm PM stepper is illustrated in figure 1. In both cases the winding and driver combination have been designed to drive the maximum current through the winding at stand without exceeding the maximum 7-watt power dissipation for this type of motor. From the chart, we see that the output power of the motor can be increased by a factor of six, through the use of bipolar constant current driver, compared to the basic unipolar L/R-driver. The increased output power is a function both the increased over-all pull-out torque and the increased stepping frequency range. As we can see from the figure, the maximum output power is available at relatively high stepping rates, compared to the maximum pull-in frequency, for this type of motor (approximately 150 to 400 Hz, for zero-load inertia, depending on driver circuit). This fact, which is true for most stepper applications, shows that, to be able to get a highperformance stepper motor system, we have use ramping up/down when we start and stop the motor and load. The use of ramping opens up stepper motors for power output

applications, and does not limit the usage of steppers to low-performing low-output power system.

Figure 1. Pull-out torque and output power for a 57 mm PM stepper driven by a unipolar L/R-driver and a PBL 3770A bipolar constant current driver.

Damping and resonance In applications with low system damping, the available output torque and power can be drastically reduced by resonance. Resonance in stepper motor systems can arise at low-, mid-, and high stepping rates. As a rule, constant current drivers have the most problems with resonance in the low frequency region. Using half stepping or micro stepping can often eliminate these resonances. Constant voltage normally has problems with resonance at medium and/or high frequencies. At these frequencies, neither half- nor micro stepping can reduce the resonance. This limits the usage of this type of drivers at medium and high frequencies to driving high-damping loads. Damping also depends on the motor type-PM motors have higher damping than hybrids, due to slide bearing friction and magnetic losses. Some driver and motor combinations have such low damping, at certain stepping rates, which they do not run without a high-damping load. This condition is known as no-load instability.

Figure 2. Performance curves for a 100 ohm unipolar 57 mm PM-motor driven by a20 L/R constant voltage driver.

Resolution and positioning accuracy The resolution of a stepper motor system is affected by several factors-the stepper motor full-step length, the selected driver mode (full-step half-step or micro stepping), and the gear rate. This means that there are several different combinations, which can be used to get the desired resolution. Because of this, the resolution problem of a stepper design can normally be dealt with after the motor size and driver type have been established. Design Time Even though customization of step motors is possible, it requires both engineering time and time for manufacturing stepper motor samples. Using a more flexible driver circuit, like the chopper constant current driver can make it possible to select a standard motor with no performance loss. Unipolar constant voltage driver attributes Features Low electronic component cost. For small motors very low cost transistor arrays can be used. Low electrical noise level. Drawbacks Lowest motor output power. Maximum power dissipation at stand still. Higher motor cost and larger size for the same output power as from other drives. Driver transistors have to withstand twie the maximum supply voltage. Winding must be designed for the used supply voltage.

Regulated power supply normally required. Holding torque depends on supply voltage and motor temperature. Large torque ripple when driven in half-step mode.

Applications Low speed and low power applications were the motor mainly is used to produce a torque. Normally only used with small size motors. Cost In high-volume applications, the major cost is the hardware-including power supply, driver, wiring, motor, and gearing. In this case, the engineering cost is less important. In many applications, it is possible to lower the total system cost increase the performance by using a more-complex driver (with a slightly higher cost) and less costly motor power supply. In low and medium applications, the engineering cost becomes a larger part of the total cost. In this case the flexibly and high integration of a constant current driver can help save engineering time and cost. Dynamic Characteristics In applications were the stepper must move from one position to another then stop in the shortest possible time, the settling time becomes a very important factor. If the system is designed properly, the settling time can be dept to a minimum-if not, the settling time can easily require several hundred milliseconds. To get good dynamic behavior in an open loop system, it is important to have the correct gear rate and precise control of the motor running and holding torque. With well designed gearing, it is possible to handle variations in both load inertia and friction.

2. Performance of drivers In the following section, the performance of some commonly used driver configurations are compared when they drive a 57 mm 7.5 degree PM stepper motor. Driving voltage/currents are selected so the stand still motor losses are kept at maximum rated 7 W. The performance curves show the pull out torque, output power (at the motor shaft), and the system efficiency. Efficiency is defined as the mechanical output power from the motor divided by the input power to the driver. For each driver, features and drawbacks are also listed. Unipolar constant voltage This is the classic low-end driver. IT offers the lowest price for the driver electronicsonly four transistors are used. To drive small sized motors, a transistor array of ULN

2003 or similar type can be used. For midsize motors, power Darlington transistors, or transistor arrays can be used. In figure 2, the performance of this type of driver is shown. A motor winding with 100 ohm phase resistance has been selected. This gives good control of winding current and low losses in power transistors. With this driver, the motor has problems with no-load instabilities at stepping rates above 325Hz.

Figure 3. Performance curves for a 100 ohm unipolar 57 mm PM-motor driven by a 40V L/2R constant-voltage driver (2 X 100ohm external series resistors).

Table 2. Unipolar L/NR constant voltage driver attributes Features Low component cost Low electrical noise level. Drawbacks Low or very low efficiency. Lower efficiency the higher Rext/R ratio. Problems with heat dissipation from the series resistors. Maximum power dissipation at stand still increase by the L/nR ratio compared to the normal L/R driver. Large torque ripple in half step mode. Holding torque depends on supply voltage and winding temperature. Applications Low and medium speed and low power applications. Unipolar L/nR constant Voltage

This driver is similar to the unipolar constant voltage but has external series resistors in series within the motor windings. This driver can configure with different L/R ratio. L/2R means that the total resistance is equal to two times the motors internal resistance. A higher L/R ratio increases high stepping rate output torque, but reduces the system efficiency. Figure 3. shows the performance of this driver in the L/2R mode, driving the same 100 ohm unipolar motor. Compared to the L/R driver we now gain higher output torque and power. The maximum output power has doubled, but the peak system efficiency ahs decreased. This drive also shows the no load instability here for stepping rates above 400 Hz. This limits the applications at high frequencies, to driving high-damping loads or to operating ramp up/down applications, were the motor does not run at constant speed. It is possible to ramp through unstable frequencies, and use the full pull out torque (with normal safety margin) if the motor only runs a limited number of steps in the unstable range.

Figure 4. Performance curves for a 100 ohm unipolar 57 mm PM-motor driven by a 40/20V Bi-level constant-voltage driver (High-voltage-on time = 4ms). Unipolar timed Bi-level The driver uses two voltage levels to increase motor utilization. At every step taken, the voltage across the winding is raised, for a short time, to a higher level compared to the nominal voltage used at stand still. During the remaining time, the nominal voltage is used. This driver can also be configured in the run/stop bi-level mode were the high voltage is used while the motor is stepped and low voltage is used at stand still. This driver can also be combined with L/nR series resistors to give higher flexibility in selecting stand-by holding torque. Ericssons PBD 3517 is fully integrated, bi level driver intended for use with small-sized motors. In figure 4, the performance of the L/2R driver is shown while driving the same 100-ohm unipolar PM stepper. The torque curve

for a given motor is a function high-voltage-on time. In this example the high voltage on time is 4ms. Compared to the original L/R driver, the maximum output power is three times higher. Compared to the L/nR driver, the efficiency is higher-and is not decreased by losses in series resistors as the ratio Uhigh/Inom is increased. This driver also has problems with no-load instability, but in this case only the mid frequencies are affected. If used in a ramp up/down application, this does not cause any problems, if the constant speed is selected in the stable area above 850 Hz. Table 3. Unipolar timed bi-level driver attributes Features Medium electronic component cost Medium electrical noise level. Drawbacks Timing circuit or extra CPU overhead needed to control high voltage on time. 6 power transistors needed compared to 4 for the standard and L/nR unipolar drivers. If large high to low driving voltage ratio is used the control off holding torque and step accuracy becomes difficult as a result of variations in winding currents. Holding torque depends on winding temperature and supply voltage. Applications Low to medium speed and low to medium power applications Table 4. Unipolar constant current driver attributes Features Nearly the same high speed torque as bipolar chopper drive Use 6 power transistors compared to 8 for bipolar constant current. Half stepping without torque ripple possible. Drawbacks Only 70% of holding and low speed torque compared to bipolar constant current. Power transistors have to withstand twice the maximum supply voltage. Winding leakage inductance have to be considered when snubbing circuit is designed. 6 lead wires add cost and space for motor connectors and flexible cables. Applications High speed and medium power applications. Unipolar constant current This driver gives the best performance of the unipolar drives-but it is lower than for the bipolar chopper driver. The efficiency is reduced as a result of higher resistive losses

caused by using only half of the windings at a time. At higher frequencies, power losses caused by leakage inductance and snubbing circuits also appear. Table 5. Bipolar constant current driver attributes Features Maximum motor utilization and high efficiency. Maximum torque at low and high stepping rates. Low losses stand bye mode possible. 8-Lead motors can be configured for 3 different operating currents. No snubbing circuits required and current turn off can be selected for fast (return to power supply) or slow. Highly integrated drivers available second sourced drives also available. Drawbacks 8 Power transistors needed to drive a motor. Problems with electrical noise and interference can occur. Power losses in current sensing resistors.

Applications For small and medium size motors highly integrated drivers are available. High speed and high power applications. Table 6. Bipolar constant current micro stepping driver attributes Features Same as for the bipolar constant current, plus: Resonance free movement on low step rates. Increased stop position resolution. Drawbacks Same as for the bipolar constant current, plus: Higher cost for the current control electronics than for normal bipolar drive. Applications For small and medium size motors highly integrated drivers are available. High speed and high power applications. Applications were increased resolution is required. Applications were resonance free low speed characteristics are needed.

Figure 4. Performance curves for a 3.75 ohm bipolar 57 mm PMmotor driven by PBL 3770A constant-current driver (Chopper voltage 20V, winding current 960mA). Bipolar constant current The higher output power and motor utilization for a given motor is achieved with the bipolar constant current driver. DC-losses is kept at a minimum due to maximum utilization of the copper in the winding and no power losses from leakage inductance and subbing circuits since every winding only consists of one part. In figure 5, the performance for this type of driver is shown driving the same type 57 mm PM-motor. Here a motor with a constant current adapted winding resistance of 3.75 ohms has been selected. The winding current is selected to give the same resistive losses in the winding at stand still as for the unipolar drives tested above. From the chart, we can see the increase of output power, maximum stepping rate, and system efficiency. Due to the better utilization of the winding, the holding torque is also raised. The no-load instabilities in the mid- and high-stepping rate regions are no longer present. This increases the flexibility in selecting constant speed running frequencies. However, a resonance at 100Hz is present. In a ramp up/down application, this does not cause any problems as long as this frequency is not used as constant speed frequency. During the last 10 years, progress in IC-technology has made it possible to develop fully-integrated bipolar constant-current drivers, making this type of driver cost-effective for driver smalland medium-sized motors. Bipolar constant current microstepping This is an improved version of the basic full- and half stepping bipolar constant current driver. Here the winding currents form a sine/cosine pair. This greatly improves low frequency stepping by eliminating overshot movements, ringing, and resonance.

Performance at medium and high stepping rates are close to that of full- and halfstepping. This driver uses the same power stage as the bipolar constant-current driver, but extra electronics for setting the sine/cosine current levels are used. Microstepping can be used with different microstep lengths. A shorter step length than 1/32 of a full-step normally does not make any further improvement in the motors motion. With most microstepping controllers, is it also possible to run the normal full- and half-step modes. Microstepping can also increase motor resolution and step accuracy. 3. General driver aspects Power supply design For all drivers of constant-voltage type, regulated power supplies are normally required. This means that the over-all system efficiency will decrease further, compared to the values shown in the figures above, due to losses in the power supply. This will increase transformer cost and heating problems. If unregulated supplies are used, large variations of holding and running torques occurs, thus madding stop-time minimizing more difficult or impossible. An unregulated power supply for a constant voltage driver also affects the motor power dissipation making good motor utilization impossible. For a constant-current driver, it is normally possible to use an unregulated supply voltage. The motor current, and thereby also holding torque and power dissipation, is controlled by the driver itself. The pullout torque at high stepping rates is affected by the supply voltage by at low step rates, it influence is small. It is difficult to calculate the power consumption for a particular application. The best way to get this information is to make a prototype and measure the driver input current under different driving conditions. Remember that the power consumption depends on input voltage, current levels (if constant current mode), load, motor temperature, duty cycle and so on. Snubbing and current turn off circuits To assure trouble-free functioning of all unipolar drives, especially when larger size motors are used, the winding and current turn-off circuit has to be properly designed. It is important that a unipolar winding is bifilar wound-this means the two wires that build up the coil on each motor pole are wounded in parallel. This way, the leakage inductance is kept to a minimum, even though the energy stored in the winding has to be taken care of (or moved to the other winding half) when the current is turned off. This is done by a current-turn off circuit or a snubbing circuit. If the current turn off circuit words on the principle of current commutation from one winding half to the other, the energy stored in a leakage inductance is handled by the subbing circuit.

In the case of bipolar drive, separate snubbering circuits are never needed, since the windings only consist of one part each and no leakage inductance can occur. The current-turn-off circuit is of four diodes in opposition to the four power transistors in the H-bridge. Hysteresis losses in motors With some low-inductance motors, chopper type drivers can generate increased iron losses, caused by the winding current ripple. To minimize this problem, use a high chopping frequency and do not use a lower inductance than needed to get maximum required step rate it is also possible to use a lower chopping voltage. In most applications, the hysteresis loss related to the chopping current ripple is low compared to the hysteresis loss related to the hysteresis low due to the stepping current changes. If chopping current ripple is dept at or below 10% of the nominal current, this normally doesnt cause a problem. Interference problems For all chopper-type drives, the increased risk of different interference problems has to be considered. Separate and wide grounding lines, as well as physical separation from sensitive electronics on the PCB, can help to avoid interference. Stepper lead wires should also be separated from sensitive signal wires to reduce capacitive and inductive coupling. Ina chopper application the capacitive coupling of the chopped voltage (this is a square wave signal with the amplitude equal to the supply voltage and the frequency equal to the chopping frequency) present at the motor lead wires can cause serious problems if not handled. 4. Performance of motors The maximum output torque and power from a stepper motor is limited by the power losses of the motor. For low stepping rates, most of the losses are related to resistive losses in the motor winding. At higher stepping rates the hystersis and eddy-current losses become t he major ones. Especially for low-cost tin can PM steppers, these losses can be high because of the absence of laminations and the use of low performing magnetic materials of the stator and rotor flow path. From the above driver comparisons, we can see that the maximum torque, efficiency, and output power from a given motor is achieved with the bipolar chopper driver. We will now examine the performance of some commonly used stepper motor types when theories are driven with a bipolar chopper drive. A drop in performance, similar that of the 57 mm PM-motor used above, can be expected when other types of drivers are used. 57-mm PM motor PM-motors are a cost-effective alternative in many low- and medium-performing applications. The motors uses slide bearing and a simple mechanical design to keep cost

low. Compared to hybrid motors, the life expectancy is shorter, step accuracy and efficiency is lower. The slide bearing can also cause problems if a belt drive is applied directly to the motor shaft. The 57-mm PM-motor is for instance, suitable to use as paper feed and carriage drive motor in medium performance matrix or daisy printers and in typewriters. Other applications are fax machines, sewing machines, value controls, and plotters. Other popular PM-motor sizes are 35mm and 42mm. 20mm, 25mm, and 63mm motors are also common PM motor sizes. The 20mm motor is popular as a head driver in 3 floppy-disk drive applications. Commonly available full-step angles are 7.5 and 15 degrees but others are also available (9,11.25. and 18 degrees, for examples). In figure 6, the performance of this motor is shown again. The power loss in plotted as a function of the stepping frequency. This motor is rated at 7 watts maximum power dissipation. The chart shows the power dissipation of the motor and driver together. At low step rates about a 3 W loss in the two PBL 3770A circuits can be expected, as well as an additional 1W in the external diodes. At decrease as the winding current decreases as the winding current decreases and the switching stops. At low step rates this gives a 7watt loss in the motor. At higher step rates, the total loss decrease indicating the ability to get a higher output power without exceeding the maximum allowed motor losses of 7W. If a lower duty cycle or better heat sinking is applied to this motor a peak output power of at least 10W can be achieved. PM-motors have one advantage over hybrid motors, they have higher motors, and they have a higher internal damping and offer, in some applications, a more-noise-free operation than the hybrid motors.

Figure 6. Performance curves for a 3.75 ohm bipolar 57 mm PM-motor driven by PBL 3770A constant driver. Power losses in motor and driver are also shown (Chopper voltage 20 V, winding current 960 mA).

Figure 7. Performance curves for a 25 ohm bipolar 42 mm square hybrid stepper driven by PBL3770A constant-current driver (Chopper voltage 40V, winding current 280mA)

42mm square motor This motor is normally manufactures with 3.6-, 1.8- and 0.9- degree step angle. Step accuracy is +-3% to +-7% of a full step. The motor uses ball bearing to maintain the very small air-gap required for high efficiency. This type of stepper motor is available able from many manufactures at a reasonable price, but the price is higher than the PM- motors. The main feature of this type of motor, compared to the 57 mm PM-motor, is higher efficiency and step accuracy. In many applications, the ball bearings offer higher life expectancy and make the design of the gearing and mechanics easier. This type of stepper became very popular some years ago as head driver for 51/4 floppy and hard disk drives. It is suitable as a carriage driver for printers and plotters, and for driving the print wheel in typewriters and daisy wheel printers. It is also a competitor to the small-sized PM-motors, if the application requires efficiency or ball bearings. Figure 7 shows the performance of a 25-ohm bipolar 3.6-degree 42mm square motor driven by a constant current driver. The current level is selected to give 4W resistive losses at stand still. This motor type is rated for 4 to 6W losses depending on manufacturer. Compared to the 57mm PM motor in figure 6, nearly doubled system efficiency is most interesting difference. From the power losses curve, we see that at higher stepping rates the losses decrease. This indicates that an even higher highfrequency performance can be achieved with a higher chopping voltage or with a lowerinductance winding.

Figure 8. Performance curve for a 2.8 ohm bipolar 57 mm hybrid stepper (length 42 mm) driven by PBL 3770A constant driver (Chopper voltage 40V, winding current 75mA).

Figure 9. Holding torque and DC-loss as functions of winding currents for a 57 mm PM motor and for a hybrid motor. 57 mm (size 23) hybrid motor This type of hybrid stepper motor is normally available with a 1.8- and 0.9-degree step angle and in a number of different lengths from 40mm to 100mm. This motor is more expensive than the two other types described above. On the other hand, a much higher torque and output power is available. The performance of this motor type is plotted in figure 10. A motor with 5-degree step angle, 2.8-ohm bipolar winding and with 42 mm length has been selected. This is the

smallest motor size of this class. The 5-degrees step angle is interesting when high shaft speed is more important than high holding torque. The diagram shows the same high efficiency as for the 42mm square motor, but fourtimes-higher output power. A maximum of over 30 W is achieved in the area of 3000 to 3500 Hz. At high step rates, the power losses of the motor are approx. 12 W (including driver 16W). This is acceptable with normal cooling of the motor and 100% duty cycle. At low step rates, the losses decrease and at standstill the losses are only 3W. This shows the ability to increase the motor current to get even higher output torque and power at low step rates. On the other hand, decreasing the low frequency torque can be a way of decreasing noise levels and vibrations in applications where the load friction torque consumes a larger part of the motor torque than the load inertia. This motor is suitable for paper handling and carriage driving in high performance printers and plotters, or industrial motion control. The 5-degree stepper, with performance shown in figure 8, is suit-able for driving her print mechanism of laser printers. PBL3770A is a suit able driver for this size of stepper motor. Power losses and holding torque The limiting factor in high performance stepper motor designs is the stepper power dissipation. Stepper motor manufactures often specify the stepper motor winding by the maximum allowed power dissipation at stand still. This gives the nominal winding voltage and current levels. In an application, the optimum performance often is achieved at different voltage and current levels. In figure 9, the holding torques of the 57 mm PM and 57 mm hybrid motors, described above, are plotted as functions of the 2 phase on current, as are the resistive power losses in the windings. From the diagram, we can see that for the PM-motor, the holding torque curve shows a knee at 600mA indicating that magnetic saturation starts to occur at his current level, even though the resistive losses in the winding is only 3W, compared to the specified 7W. This indicates that using the specified current level of 960mA does not give the optimum performance on low stepping rates. Figure 10 shows the affect on motor and driver performance when the winding current is decreased to 480mA. Comparing figure 6 and 10 shows the improved low-frequency performance. Low-speed losses are decreased to less than 50% and low speed torque only drops to 80%. In the high stepping rate region, only small loss in torque appears. In figure 13 another combination of driving current and voltage is used to increase the output power to 5.5W with the same maximum losses as in figure 6. Now the losses occur where they are more motivated at the stepping rate where the maximum output power appears. For the hybrid motor, we see that the winding current can be increased beyond the maximum rating without causing too much saturation effect. In figure 8, the torque from

this motor shows a relatively-flat torque characteristic for stepping rates below 3kHz. This is a result of the 750mA current level not using the full low-speed capabilities of this motor. Increased current will raise the output torque at low speeds and make the region with maximum output power wider (towards low frequencies), but it will only increase the peak output power marginally. 5. Designing a system Analyzing the load When designing a stepper motor system, the first question to ask is what are the characteristics of the load? Too often, this question is given too little consideration. To get the best performance, it is important to do an analysis before selecting motor and driver and before designing the transmission and mechanical system. Friction or inertia loads If the system will have high dynamic performance, (high acceleration/retardation), then most of the output torque from the motor will be used to accelerate the systems inertia. To get the maximum performance from this type of system, the gear rate should normally be designed so that the load inertia seen by the motor is close to the motor internal inertia. The load inertia seen by the motor is: J Im = J1 Gr2 J1 = load inertia without gearing Gr = the gear rate A friction torque is reduced by the factor 1/G, by a gear mechanism.

Figure 10. Performance curves for a 3.75 ohm bipolar 57 mm PM-motor driven by PBL3770A constant-current driver. (Chopper voltage 20V, winding current 480 mA).

Figure 11. Performance curves for a 3.75 ohm bipolar 57 mm PM-motor driven by PBL3770A constant-current driver. (Chopper voltage 25V, winding current 600 mA). Friction torque/load power consumption To select the right motor size and driver type, it is necessary to calculate torn measure the load friction torque. For most type of loads, this is fairly constant at different speeds, which makes measuring easy. If the system involves a linear motion, a spring scale can be used and for rotating system, a torque watch can be used. From the measured force or torque, and information about the maximum speed of the motion, the maximum needed load power can be calculated: P[W ] = v[m / s ] F [ N ] for linear systems and P[W ] = [radians / s ] T [ Nm] for rotating systms. Another way of estimating the load power consumption is to replace the motor or motor and gearbox with a DC-motor with known current to torque function and drive the motor at the desired speed while measuring the current consumption. If this technique is used, it is possible to measure the power consumption at different speeds. Damping As noted earlier, the usable torque from a stepper motor can be decrease at certain stepping rates due to resonance. At which step rates, and to what extent, this torque deduction appears depends on the application damping and inertia. The dampings of the driver also influence the torque reduction. Resonance at low stepping rates can normally be reduced by lowering driver current and voltage levels, or by selecting half of micro stepping mode drivers. At medium step rates the constant current drivers normally have the least problems with resonance, by the characteristics of the load have large impact.

Low system inertia normally crates fewer problems with resonance. However, in some applications, an increased inertia can be used to move a resonance to a lower frequency. Selecting concept After analyzing the load, we know the output power needed, the maximum and minimum stepping rates, and the resolution needed. Depending on the importance of the different demands and the ability to fulfill them, the designer has range of options in combing motor gearing driver and gearing. A higher step rate driver and a smaller motor, together with a suitable gearing, often gives a better performance in efficiency and output power-than a large motor driving the load directly. 6. Motor Selection Output power This is the most important design criterion in getting the best price/performance of a stepper motor system. Compare the power requirements for the load with the data given above, or with the data in the manufactures data sheet. If the manufactures data sheet is used be aware of the big differences in performance of the stepper motors due to different drivers. Also remember that measuring stepper motor pull out and pull in torque is tricky. The measurement is easily influenced by inertia and resonance in the measuring system, and the inertia and damping of the application is normally different. As a result, the pullout curves in the data sheet are not always valid for an actual application. Mechanical aspects The physical dimension and weight of the motor are important criteria when a motor is selected. Often the choice of smaller motor can make a compare mechanical design easier. A smaller motor can also, if the motor is in a moving part of the mechanism, make the design of the motion system easier. In applications where long life expectancy is needed, motors with ball bearings are required. Hybrid motors use ball bearing as a standard (to maintain the narrow air-gap), but small sized PM motors usually use slide bearings. PM motors, with ball bearing as an option, are supplied by some manufactures but the additional const for this rather high. If the motor drives a belt gearing or a belt transmission directly, ball bearings are strongly recommended. This ensures proper lifetime and reduces torque loss due to bearing friction caused by the belt tension. Cost The motor cost depends on motor type and size. Winding type and resistance do not affect the cost. As a rule, hybrid motors are more expensive than PM-motors. The motor cost normally increases with motor size. Another factor that influences the motor cost is the production volumes of a certain motor and the number of manufactures of that motor.

This means that times a popular type and size motor output power is a little higher than required. Customizing the motor In medium and high volume applications, it is possible to customize the motor. Most manufacturers offers customization on the following items. Shaft: single or double-sided, length, pinions Winding: Resistance, Inductance Rotor: Type of magnets, hybrid air gap distance Lead wires: Length connector From some manufactures, other parameters such as shaft diameter, bearing types, mounting flange can be customized by this is normally applicable only in high-volume applications. 7. Driver design Selecting driver type The performance curves at the beginning show the effect of the driver on the system. If only low stepping rates are used and the use of gearing is not a solution, the unipolar L/Rdriver offers the lowest cost for the electronics for a given output torque. As demanded for output power from the stepper increases, more-effective drivers offer the best price performance ratio. The best motor utilization is achieved with the bipolar constant current driver and this driver is the obvious choice for all high power applications. For applications in the low and medium power range, several alternatives exist. If system efficiency is important, then the bipolar constant current driver is the best choice. This driver offers higher flexibility in selecting the motor winding, since both the chopper voltage and the current in the winding can be changed to get the desired pull out torque curve from the motor. Power supply design gets easier and power supply losses decrease since regulated supply normally is not needed for constant current drivers. If minimum cost for the driver electronics is the most important design criteria, rather than the over all system performance, then the over all system performance, then the different unipolar driver can be the best choice.

Figure 12. Performance curves for a 3.75 ohm bipolar 57 mm PM-motor driven by PBL3770A constant-current driver. (Half-step mode fast current decay. Chopper voltage 20V, 2-phase-on current 480 mA).

Figure 13. Performance as a function of chopper voltage for a 25 ohm bipolar 42 mm square hybrid stepper driven by PBL3770A constant-current driver (Chopper voltage 40/30V, winding current 280mA).

Figure 14. Performance as a function of winding current for a 25 ohm bipolar 42 mm square hybrid stepper driven by PBL3770A constant-current driver (Chopper voltage 40V, winding current 280/220mA) Selecting driver mode Full-Step Mode: This is the basic stepper-driving mode, it offers the simplest control electronics and it is recommended for high and medium frequency operation. At these frequencies, the inertia of the motor and the load smooth out the torque, resulting in less vibration and noise compared to low-speed operation. Half-Step Mode: Half stepping with 140% 1-phase on current gives smoother movement at low step rates compared to full stepping and can be used to lower resonance at low speeds. Half stepping also doubles the system resolution. Observe that for most steppers, the step accuracy specification only is valid for 2-phase-on positions. The accuracy is lower and the stop-position hysteresis is larger for 1 phase on positions. Figure 12 shows the effects on performance of the 57mm PM-motor when half stepping is applied to this motor. Compared to full stepping a slightly higher torque at low speed and a small decrease at higher step rates. The main advantage is the lowered noise and vibrations at low stepping rates. If maximum performance at both low and high step rates is essential, a switch to full step mode can be done at a suitable frequency. Change the stepping mode this way will also lowers CPU-time requirement (step rate reduced by 50% at high speeds) if the system use a microprocessor as control unit. Microstepping: The smoothest movements at low frequencies are achieved with microstepping. Higher resolution is also offered. If resonance free movement at low step rates is important, the microstepping driver is the best choice. Microstepping can also be used to increase stop position accuracy beyond the normal motor limits.

8. Designing the Winding For a constant current chopper type driver the winding design depends on the desired output power, maximum operation frequency, and chopper voltage. A simplified design method, which in most cases when high output power is important, gives a good result is described below. EMF selection A good design criteria for winding design is the EMF (electromotive force) of winding. The optimum motor performance efficiency and output power is achieved close to the step frequency where the EMF peak value is equal to the driving voltage (chopper voltage in the case of constant current drive). As an example, the 42mm square motor, with performance as shown in figure 7, has an EMF constant of 20m V/Hz (full step frequency). With a 40-volt chopping voltage, this gives a optimum stepping rate of 2kHz. From figure 7, we see that at 2kHz both the efficiency and the output power are at their maximum values. To design a winding for 20 volts, with a maximum output at eh same stepping rate, a winding with 10mV/Hz EMF constant should be used. This winding will have half the number of turns and thus of the resistance and inductance of the original winding. To get the same holding toque and low frequency performance the winding current has to be raised to twice the original value. It is not possible to increase the optimum stepping rate for a motor to very high values since then hysteriss loss and rotor leakage inductance will decrease the efficiency. The EMF constant for a motor is measured by connecting the motor winding to an oscilloscope and rotating the rotor at a constant speed (by means of a DC-motor for instance) and measuring the peak value and the frequency of the generated signal. The generated frequency corresponds to four-times-higher full-stepping rate. From this the EMF constant can be calculated. Figure 13 shows the affect on the torque and output power of the 42mm hybrid motor when the chopping voltage is decreased. From the figure, we can see that the optimum operating frequency moves from approximately 2kHz to 1.5kHz when the chopping voltage is decreased from 40 to 30 volts. Using the EMF-rule we get the same result: 20mV / Hz 1.5Hz = 30Volts Selecting the current level In a constant-current driver the driver-current level mainly affects the torque at the low frequencies. Depending on the load torque demand (friction and inertia) as a function of stepping rate, it is often a good idea to reduce the current level to get a more-flat torque characteristics from the motor. This normally decreases resonance and power losses and allows a lower-rated driver circuit. In figure 14, the effect of decreased winding current is shown-from the curve we can see that only the low and medium frequencies are affected by the lower current. Power

losses at low step rates have also decreased. The peak output power, however, is not affected, as the torque at 2kHz is not decreased. 9. Summing up The unipolar L/R driver offers the lowest cost for the electronics for a given output torque, if the step rate is low. As demand for output power from the stepper increases, more effective drivers offers the best price performance ratio. The best motor utilization is achieved with the bipolar constant current driver and this driver is the obvious choice for all high power applications.

Appendix I:

Half Stepping Techniques

By operating a stepper motor in half stepping mode it is possible to improve system performance in regard to higher resolution and reduction of resonance. It is also possible to reduce torque variations to achieve and even smoother motion and more precise positing by modifying the half step mode. The electronics and programming, as well as the theoretical background involved in the generating the necessary signals for half stepping using Ericssons stepper motor drivers are described in this application note. The rotating magnetic field The basic principle of driving the stepper motor is to generate a rotating field is generated in the stator by current in the two-phase windings (see figure 15). The direction and the magnitude of the magnetic field is described in a vector diagram (see figure 16). To create a two-dimensional vector at least two coordinates have to be controlled the xand the Y-axis coordinate. In the following these X and Y axes are also referred to as the stator axes. The two windings in figure1 generate a magnetic flux, which is aligned to the two-stator axis. The current ratio between the two windings gives the total magnetic field vector it is direction and the length of the vector represents the added magnetic flux amplitude. These vectors are shown both in figure 15 and 16. The torque ate he shaft (axis) is proportional to the magnetic field. Referring to figure1: If the phase A and B are energized, the rotor can step form position1 to position 3, 5, 7 and son on in either direction, depending on the magnetic flux direction which is controlled by the current direction in the two windings. This drive is normally referred to as two-phase on drive. If only one stator coil is energized at time the rotor can step from position 2 to 4, 6, 8 and so on. This drive mode is referred to

as one-phase-on drive. Both of these two drive modes will result in full stepping, but the full step positions are shifted on half or a full step.

Figure 15. Two phase motor.

Figure 15. Direction and amplitude of the magnetic field.

Halfstepping If these two drive modes are combined and corrected sequences are fed into the windings the rotor can be made to align at all positions i.e 1, 2, 3, 4 and so on. This is referred to as half-step mode. Figure 17. describes the current time diagram, it includes input signals and a current direction table as well at the magnetic field direction. The first part shows the two-phase-on drive where the motor steps from pos 1 to 3, 5, 7. In the second part of the diagram, a half step sequence is fed into the windings. Compared to full-step drive, half step drive gives some major advantages: Higher resolution (without use of more expensive motor with higher number of steps). Less problems with resonance phenomena. Resonance appear as a sudden loss of torque at one or more stepping rates.

Half stepping usually overcomes these resonance problems. However a disadvantage with half-step drive is a significant torque variation. The reason is the torque in one-phase-on positions is about 70% of the two-phase on positions torque. This variation can cause vibrations and/or mechanical noise, through less than in full-step drive mode.

Figure 17. Input signals, output current and magnetic field direction for the different rotor positions in figure 15.

Appendix II: Stepper Motor Figures

Figure 1. Stepper motor step sequence.

Figure 2. Dynamic response of a single step.

Figure 3. Stepper motor torque-speed curves.

Figure 4. Standard unipolar stepper motor field coil schematic.

Figure 5. Example of a unipolar stepper motor.

Figure 6. Unipolar full-step phase sequence (A) and half step phase sequence (B)

Figure 7. Typical stepper motor rotor and stator configuration.

Figure 8. Actual stepper motor rotor.

Figure 9. Unipolar stepper motor full-step drive circuit.

Figure 10. Timing diagram for full-step unipolar stepper motor drive circuit.

Figure 11. Typical stepper motor performance curves.