Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Elster-Instromet M2000 FC

Download as pdf or txt
Download as pdf or txt
You are on page 1of 0

Model 2000

Web-enabled ow computer
Applications
High accuracy gas and liquid ow computer *
Station controller, liquid prover / grab sampler and valve
& PID loop controller
-
-
Brief information
Scope: The Model 2000 web-enabled ow computer is designed for hydrocarbon
liquid and gas measurement and control applications. The advanced features sup-
port exible congurations for multi stream scal and custody transfer measurements
based on volume, mass and energy calculations using the latest applicable AGA, ISO
and API standards available.
Model 2000 can be congured for use either as stand-alone single or multiple stream
ow computer supporting turbine, rotary, ultrasonic, orice, density, venturi and co-
riolis ow meters or as a system component serving station controller, liquid prover /
grab sampler or valve & PID loop control functionalities.
The top of the range Model 2000 ow computers provide remote control capabilities
using web-based TCP/IP technologies for remote front panel operations, conguration
set-up and pass-through communication ports enabling remote meter and transmit-
ter diagnostics.
Model 2000 innovative digital technology: Elster-Instromets involvement with ow
computers started 30 years ago, but the last decade has shown a quantum leap
through the use of digital technology. The ow computers have evolved from pure
analogue stand-alone machines into the current state of the art digital web enabled
system components ready to meet the challenge and requirements of the 21st century
large scale liquid and gas metering.
Complete digital signal handling of SMART temperature, pressure and differential
pressure transmitters through proven 32-bit high-speed microprocessor technology
guarantees the full accuracy of the measurement is preserved. Ambient temperature
dependence of signals is eliminated and the system performance is solely limited to
the inherent accuracy of the transmitters. Digital communication is also used when
connecting to turbine, rotary and ultrasonic ow meters, gas chromatographs and
other energy measurement devices.
The Model 2000 digital ow computer features distributed processing and dual port
memory access techniques to accomplish maximum system performance. All I/O
cards have local processing capabilities to support on-board signal interfacing, con-
trol and alarming functionalities.
For turbine, rotary, ultrasonic, orice, venturi, and coriolis ow meters *
Main features
High accuracy (error < 0.1%)
100/10 Mhz Ethernet ports
Multiple P, T and P transmitters
Online density and relative density
measurements
Single or multiple stream(s)
Compatible to a wide range of
gas chromatographs
Data, audit and alarm loggers
Liquids & gas calculations to
AGA / ISO / API
Congurable display menus,
symbols, units
Max. 5 multifunctional I/O boards
Windows conguration software
USB programming interface
Metrological approved: NMi, METAS,
BEV, GOST, UKRAIN
Pattern evaluation reports: EN12405

2
Model 2000: Web-enabled ow computer
Accuracy and reliability
Both energy conservation and efciency
improvement in oil and gas utilisation
call for more accurate metering. Open
access for third parties to transmission
lines or even distribution systems has
been introduced in many countries and
is gaining further support from regula-
tory bodies. Under such a regime where
a pipeline owner only receives a fee for
the transportation without the opportuni-
ty to prot from the gas sales, the nan-
cial risk of inaccuracies or malfunction of
metering equipment may be very high,
especially on short distance transmis-
sion. Reliability is at a premium for the
Model 2000, both where it affects ac-
curacy of metering and where it affects
operation.
Adaptability and exibility
Todays oil and gas metering calls for
adaptable solutions both in hard- and
software design. The Model 2000 ow
computer offers this exibility in provid-
ing a large range of modular I/O inter-
face boards supported by advanced
user programmable software features.
The menu (icon) driven Model 2000 Win-
dows interface is highly thought of by
many of our worldwide customers.
Metering compatibility
The Model 2000 ow computer is de-
signed to calculate the energy, mass
and volume totals and instantaneous
ow rates of gas and hydrocarbon liq-
uids. Calculations are carried out using
inputs from pulse generating turbine/ro-
tary meters, ultrasonic meters, coriolis
meters, venturi meters or from differen-
tial pressure measurements across ori-
ce plates together with line temperature
and line pressure transmitters. It uses
preset or active input values of relative
density, gas composition data and heat-
ing value. Active values can be received
directly from gas chromatographs or can
be written serially from supervisory sys-
tems.
Compressibility
The ow of gas is calculated using gas
compressibility equations (Z) selected
from a list of which includes AGA 8,
ISO 12213, AGA 3 NX19 as well as xed
factors or table factors for non natural
gases. Alternatively the ow of gas can
be calculated using a transducer for line
density. The ow of liquids is calculated
using xed or measured factors for den-
sity and relative density and correction
based upon measured temperature
and pressure of the liquid in accordance
with the API standards chapter 11.2.1M,
11.2.2M and chapter 12.
Sensor select and alarming
Facilities of both high and low alarming
on all active input signals are available.
The alarms can be selected to enable a
default value, a serial check value (from
supervisory systems), an average value
or a input value from an alternative sen-
sor to be used in the ow calculation for
the parameter in alarm. Indication is giv-
en of the time of occurrence and clear-
ance of the alarm state. Solid state alarm
output signals are also provided.
Digital process inputs
Digital communication (by HART proto-
col) is supported for differential pressure,
pressure, temperature and multi-vari-
able (dP,P,T) transmitters eliminating the
need for calibration of the Model 2000.
This feature also eliminates the errors in
ow measurement due to ambient tem-
perature effects on the Model 2000, only
the temperature coefcients of the trans-
mitters contribute to the overall error.
As an alternative the Model 2000 can be
operated from transmitters that supply
4-20mA current output and also direct
from a 100 ohm platinum resistance ther-
mometer for temperature measurement.
These types of input are measured using
analogue inputs and a high resolution
(24-Bits) A-D converter. All analogue in-
puts are calibrated using software.
Conguration
and programming
3
FC2000
FC2000
Station controller
ADSL / GPRS / UMTS
network connection
Router
RS485
Gas chromatograph
ENCAL 3000
R
S
4
8
5

M
u
l
t
i
-
D
r
o
p
E
t
h
e
r
n
e
t
Serial communication ports
Two high speed serial RS232/RS485
communication ports are provided as
standard on the MPU module for data
communication to a wide range of sys-
tem devices or printers. Two or more
extra serial ports can be used when
tting a COMMS module. All ports are
programmable for the hardware mode
of operation (RS232/ RS485), baudrate,
parity, start and stop bits and hand-
shaking protocols. A wide range of pro-
tocols and functions can be assigned to
each port e.g.:
Modbus ASCII or RTU
Password Modbus ASCII / RTU
E-I ultrasonic (uniform / RTU)
E-I ultrasonic (thru-port)
E-I ENCAL 3000
Chromat ASCII or RTU
Panametrics GM868
Daniels senior sonic
Sick Flowsic 600 (Modbus ASCII)
Micro motion RFT9739 (ASCII)
Serial printer
Station controller
Smart index / F1 Encoder
-
-
-
-
-
-
-
-
-
-
-
-
-
PID analogue output control
An analogue output function is availa-
ble that can be used to control process
variables like ow rate, temperature,
pressure, etc. via analogue output sig-
nals. The PID function uses the differ-
ence between a set point and a proc-
ess value as input for its calculation.
The analogue output value is control-
led to be the sum of a proportional,
integral and derivative action. It has
a forward / reverse parameter to use
the controller in the correct direction.
Gas chromatograph support
Since the Model 2000 can be used in a
variety of gas measurement applications
we have expanded our compatibility to a
wide range of leading manufacturers of
gas chromatographs e.g.:
E-I ENCAL 2000/3000 (EU/USA)
E-I ENSONIC
Daniels 2251, 2551, 2350
ABB 8000/8100
ABB 3100
Yamatake HGC303
Siemens Optichrome
Rosemount GCX
OSC-01-E (Gasunie NL)
Multiple density transducers
The density inputs for the Model 2000
are high frequency periodic inputs. Two
brands of density transducers are sup-
ported: Solartron and Sarasota. On
alarm the FC2000 calculations can be
programmed to continue with density
keypad values, or alternative density val-
ues can be calculated from AGA8. Hourly
and daily averages are available.
Optionally one density input can be con-
gured as relative density input. When
this type of input is selected this meas-
urement will take priority over any value
received for relative density from a gas
chromatograph.
-
-
-
-
-
-
-
-
-
Serial communication
features
44
Model 2000: Web-enabled ow computer
Model 2000 Ethernet access
Network 2 module
Networking module
The Model 2000 can be equipped with
one or more (independent) Network 2
modules. Each module provides a fast
10/100 MHz Ethernet port connection via
a standard 8-pin RJ45 connector. Initial
set-up and conguration of the Ethernet
ports is done via the front panel USB pro-
gramming port together with the Model
2000 Windows programming tool.
Correct connection to a network and
communication is ensured by LED status
indicators.
Model 2000 Ethernet features
The Ethernet port(s) allow full remote
conguration as well as data collection
of the Model 2000. Protocols like TCP/IP
and Modbus over TCP/IP are supported
as standard while others are under de-
velopment. Multiple (PC) servers are al-
lowed to access metering data from
multiple ow computers in a web-based
network system using standard avail-
able routers or switches. The Ethernet
package data transfer is far more ver-
satile than any other communication
protocol. It allows data communication
from any device to any other device (no
dedicated master/slave) using unique IP
address techniques and supports mod-
ern communication networks like GPRS,
ADSL, Fibre-Optics, etc..
Remote front panel access
A unique feature of the Model 2000
Ethernet 2 module is the support for re-
mote front panel operations. Access is
provided using a standard web browser
(Explorer) application selecting the IP-
address of the device. On connection a
JAVA applet will be started automatically
and a virtual Model 2000 front panel will
pop up. The PC mouse (or keyboard) is
than used to activate any of Model 2000
keyboard buttons. All local keyboard
and front panel functions are supported
remotely (including alarm-log access
and edit functions). The remote front
panel assists remote maintenance. Any
local operator can be guided through
the various menus from remote (and
vice-versa).
Network pass through
Network pass through capabilities of-
fer another unique aspect of the Model
2000 Ethernet functionalities. It allows
any remote PC or supervisory system to
access directly pressure or temperature
transmitters, meters and/or gas chro-
matographs connected to the Model
2000 ow computer using any specic
serial manufacturers protocol. Remote
serial diagnostics software can be used
since the serial RS232 port is emulated in
the PC or supervisory system.
Pass through communication is suit-
able for many applications. For example
to remotely read and congure HART
transmitters using software packages
provided by transmitter manufacturers
or third parties e.g.: AMS or PACTware.
Similarly uniform protocols can be used
to read or diagnose ultrasonic meters
remotely. Modbus packages over TCP/IP
can be used to retrieve online and stored
(logged) data from any Model 2000 ow
computers for storage in supervisory
systems.
Ethernet advantages
Fast communication, worldwide
Very good error recovery
Multiple protocol support
Modbus over TCP/IP
Multiple PC - multiple FCs
Up to 7 sessions per FC
Remote front panel operation
Network pass through
Emulated RS232 port
Easy set-up (using USB front panel)
Remote diagnostics
Remote Model 2000 conguration
(Currently under development)
Remote rmware download
Network printer support
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Web-enabled
Ethernet access
5
Liquid prover application
ISS supervisory systems
Elster-Instromet is specialised in gas
measurement for more than 30 years.
During this time we have not only prov-
en to be a reliable manufacturer of the
highest quality, but also a exible solu-
tion provider of high accuracy measure-
ment systems. The turn-key solutions are
tailor made and range from small district
metering and reduction stations to cus-
tody transfer border stations. Complete
solutions include meters, skids, analyser
houses, ow computers, station control-
lers, control cabinets and supervisory
systems are widely used in many on
and offshore applications.
This expertise has led to one of the
most advanced custody transfer super-
visory systems available on the market
at present. The core of the system is the
Elster-Instromet Supervisory Suite (ISS)
software being more than a SCADA
package. ISS is developed specically for
gas and liquid applications where ac-
curate calculations, data processing and
reporting are of the utmost importance.
Such applications include gas & liquid
metering stations, calibration installa-
tions, telemetry, remote metering, billing
and pipeline monitoring systems.
As a system component this is where the
Model 2000 web-enabled ow compu-
ter / station controller ts best.
Data loggers
Model 2000 can be congured to log up
to 16 different tables of data. Each table
can be congured to log any parameter
either at a programmable time interval
(1 min. to 1 month) or at the occurrence
of an event. The number of logs for each
table can be set. The maximum number
of items is dened as the sum of all ac-
tive tables up to a maximum of 150,000
items for a Model 2000 with a large
memory MPU board tted.
Alarm logging
Alarm logging is provided at the occur-
rence and clearance of each alarm, fault
and warning. Up to 160 separate alarms
can be stored and indicated with date
and time of the occurrence.
Audit / event log
An audit / event log is available to record
up to 500 events with date and time of
occurrence. To and from values for data
changes are stored to support audit trail
facilities.
Logs retrieval
All data, alarm and audit/event logs can
be retrieved from Model 2000 using the:
Front panel USB port
Network ports
-
-
Modbus serial ports
Optional serial printer port (for direct
paper reporting)
The logs can be stored on a PC or super-
visory system or be exported directly into
spread-sheets for additional processing
by mainframes.
User congurable display
Not only the language of all display pa-
rameters and their names can be cong-
ured also the items which are required to
display are user dened.
Report printing
Report printing is supported in a very
user friendly and exible manner. Multi-
ple free-programmable user dened re-
ports can be generated using the Model
2000 conguration software. Available
print options are:
Alarm print, automatic data mode or
in maintenance mode print
Front panel print button
History type reports
Daily, weekly or monthly reports
Multiple contract times
Data in any format or decimal places
Print logged data
Print maximum, minimum or average
columns
-
-
-
-
-
-
-
-
-
-
Supervisory and logging
6
Model 2000: Web-enabled ow computer
Technical data
Hardware architecture Motorola Coldre microprocessor 32 bits, 40 MHz
RAM data memory 16 MBit, ash program memory 8 or 16 MBit, EEPROM preset memory 1 MBit -
Calculation gases Compressibility: AGA3-NX19, GOST, AGA 8 (full composition), ISO 12213, Fixed Z, Table Z
Flow calculations: ISO 5167 (2003), AGA 3; STACA / CATS (North Sea) Equation Support
Heating Value & Relative density: ISO 6976 (mass or volume based) (molar percent or mass fraction)
AGA Report No. 9 - US Meter; AGA Report No. 7 - turbine Meter
Density Density and relative density periodic type transmitter support.
Solartron or Sarasota equations
Upstream or downstream calculation
Temperature and/or VOS compensation
-
-
-
Calculation liquids Simple xed density:
Water or fuel oil (xed K-factor)
Condensate based measured density:
Oils
API Chapter 11.1 Tables 53A and 54A - NORSOK I-105
API Chapter 11.2.1 and 11.2.2 - ASTM-D-1250
API MPMS 12.2.5.3 & 4
-
-
-
-
-
Prover functions API MPMS12.2.5.1 to 4
Pulse integrity API 5.5 level A, ISO6551 level A, pulse interpolation, dual pulse chronometry
Steam ISO 5167 Venturi Equations
Wet gas ISO 5167 Orice and Venturi equations
De Leeuw correlation
Dickinson Jamieson correlation
Steven correlation
Chisholm correlation
Homogenous correlation (measured line density)
-
-
-
-
-
Station controller Up to 5 (optional 8) ow computer can be served
Station pressure and temperature measurement
Distribution of gas data to all connected ow computers
Station totals and ow calculations, display and reporting
Average gas data calculation
Stream ow comparison (mixed types e.g. turbine and ultrasonic)
-
-
-
-
-
Ethernet One or more independent Ethernet ports (10/100 MHz)
Multiple protocol support, Modbus over TCP/IP, remote front panel operation
Remote diagnostics, conguration and set-up, max. 7 sessions per Ethernet port
Pass through communication support
-
-
-
Serial ports Two or more isolated serial ports (RS232/RS485) programmable baudrate up to 115kB
Station totals and ow calculations, display and reporting -
Analogue / pulse outputs 4 analogue 4-20 mA current loops (16 bit D/A conversion max error 0.15%) per output module
12 pulse / alarm or status opto-coupler outputs per output module
Inputs (per module) 2 pulse counting / frequency inputs (5kHz) for turbine (pulse) or density input signals
2 HART transmitter loops (max. 3 transmitters per loop)
4 analogue inputs 4-20mA (24 bit A/D conversion)
1 (optional 2) direct PRT input(s) (3 or 4 wire)
3 digital status inputs
Power supply 21 to 28 V DC maximum 25 VA
Display Liquid crystal with backlight, large viewing area 130 x 34 mm with 240 x 64 pixels
Dimensions / mounting Custom designed and manufactured construction,
Dimensions 128 x 213 x 235 mm (H x W x D)
Half 19 (3U) rack mounted or panel mounted
Temperature range Operating 0 to +60 C, storage 0 to +70 C
Accessories Rack mounted counter module (max. 4 electromechanical counters)
Printer unit using ink ribbon with integral paper rewind
19 rack for cabinet mounting, will hold two M2000 or one M2000 with a printer and counter module
USB programming cable and Windows conguration software
-
-
-
7
Module type MPU
MPU
ext. memory
Part number FC2000-SP. 2134 2024
32 bit high speed MPU (40MHz) x x
16 Mbit data memory (RAM + battery backup) x x
8 Mbit progam memory (FLASH) x
16 Mbit progam memory (FLASH) x
1M preset memory (EEPROM) x x
2 isolated RS232/RS485 serial ports x x
Module type Comms Comms 2
Part number FC2000-SP. 2032 2087
2 isolated RS232/RS485 serial ports (up to 115 kbaud) x x
Dual port memory access (multiple serial boards possible) x
Module type Input Input 2 PRT PRT 2
Part number FC2000-SP. 2037 2080 2030 2085
2 HART inputs (each 3 transmitters) x x x x
4 current inputs 4-20 mA (24 Bit) x x
1 PRT input (PT-100 3 wire) x x
2 PRT inputs (PT-100 4 wire) x x
3 digital status inputs x x x x
2 HF inputs x x x x
1 prover pulse output x x
Pulse integrity check x x
Module type Output Output 2
Part number FC2000-SP. 2033 2083
4 isolated current loop outputs 4-20 mA (16 bit) x x
12 isolated switching outputs (opto-coupler) x x
Analogue output calibration switch x
Module type Network 2
Part number FC2000-SP. 2088
1 Ethernet connection (10/100MHz) RJ-45 - 8 pin x
Remote front panel operation x
Modbus TCP/IP support x
Pass through communication enabling transmitter diagnosis x
Conguration set-up x
Module type Power supply
Part number FC2000-SP. 2038
1 power supply input nominal +24VDC (21 to 28 VDC, 25 VA) x
1 auxiliary output supply +24VDC (fused) x
MPU
Comms
Input
Output
Network
Power supply
I/O interface modules
Your contacts
A06.09.2007
Model 2000 EN02
Germany Belgium Singapore
Elster-Instromet GmbH Elster-Instromet N.V. Elster-Instromet
Steinern Str. 19 - 21 Rijkmakerlaan 9 Singapore Representative Ofce
55252 Mainz-Kastel 2910 Essen 80 Marine Parade Road
T +49 6134 605 0 T +32 3 670 0700 09-04 Parkway Parade
F +49 6134 605 223 F +32 3 667 6940 Singapore 449269
www.elster-instromet.com www.elster-instromet.com T +65 6247 7728
info@elster-instromet.com info@elster-instromet.com F +65 6247 7729
S
u
b
j
e
c
t

t
o

c
h
a
n
g
e

w
i
t
h
o
u
t

p
r
i
o
r

n
o
t
i
c
e

A
l
l

r
i
g
h
t
s

r
e
s
e
r
v
e
d
Model 2000: Web-enabled ow computer
Model 2000 Type selection guide
Features Streams Flow meter type Flow correction Primary ow measurement
HART Serial
Application Model 2000 Type
Gas
T1, T2, T3 1 3 x x x x opt. x
U1 1 1 x x x x opt. x
U2, U3, U4 2 4 x x x x opt. x
O1, O2 1 2 x x x x opt. x
TD1, TD2, TD3, 1 3 x x opt. x
UD1 1 1 x opt. x
UD2, UD3, UD4 2 4 x opt. x
OD1, OD2 1 2 x x x x opt. x
Liquid
LT1 1 1 x x x
LTD1 1 1 x x x
LC1, LC2 1 2 x x opt. opt. x x
Steam VT1, VT2 1 2 x x x x x
Wet gas
WGV1 1 1 x x x x x
WGV21, WGV22, WGV23 1 3 x x x
Station controller
STN5 1 5
Controller applications (non measurement) STN8 1 8
Prover Liquid prover 1 4
Other Model 2000 advanced features
Cost effective for all congurations
Reliable reputation both hardware and software
Flexible conguration for all applications
Windows 2K, NT and XP compatible conguration software
Software can be congured at ofce PC before downloading in Model 2000
Software updates and conguration can be sent immediately via e-mail
Fully secure using password and security switch protection
Integrated rmware downloader in Windows conguration software
Self checking of data and memory for correct internal operations
15 minute totalizers
Maintenance mode and hold totals mode
Metric and imperial units
Valve control outputs (selectable pulse on-time, use in odorization)
Turbine meter lubrication support
Pollution measurement for power stations (emission factor calculations)
Liquid grab sampler system support
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
M
i
n
i
m
u
m
M
a
x
i
m
u
m
T
u
r
b
i
n
e

/

r
o
t
a
r
y

(
v
a
r
i
o
u
s

b
r
a
n
d
s
)
U
l
t
r
a
s
o
n
i
c

(
v
a
r
i
o
u
s

b
r
a
n
d
s
)
O
r
i


c
e

p
l
a
t
e
C
o
r
i
o
l
i
s

(
m
i
c
r
o

m
o
t
i
o
n

R
F
T
9
7
3
9
)
V
e
n
t
u
r
i
V
e
n
t
u
r
i

2

(
F
l
o
w

l
i
n
e

s
t
r
e
a
m
)
D
e
n
s
i
t
y

(

)
P
r
e
s
s
u
r
e

(
P
)
T
e
m
p
e
r
a
t
u
r
e

(
T
)
C
o
m
p
r
e
s
s
i
b
i
l
i
t
y

(
Z
)
G
a
s

c
h
r
o
m
a
t
o
g
r
a
p
h

(
H
s
,

g
a
s

d
a
t
a
)
P
u
l
s
e

t
y
p
e

m
e
t
e
r
D
i
f
f
e
r
e
n
t
i
a
l

p
r
e
s
s
u
r
e

(
d
P
)
M
u
l
t
i

v
a
r
i
a
b
l
e

m
a
s
s


o
w

(
d
P
,

P
,

T
)
U
n
i
f
o
r
m

o
r

M
o
d
b
u
s

R
T
U
M
o
d
b
u
s

R
T
U

m
u
l
t
i
d
r
o
p

You might also like