Technical Data Sheet D11

2006-03

D11 Knauf Board Ceilings


D111 wood frame D112 metal grid CD 60x27 D113 flush metal grid CD 60x27 D116 metal grid UA 50x40 + CD 60x27

New
Design options for fire protection F30 to F90 solely from below and from above

D11 Knauf Board Ceilings


Basics of Dimensioning
Dimensioning of substructure 1. Determination of the weight of the ceiling lining / suspended ceiling depending on thickness of cladding Depending on the chosen thickness of cladding in mm (x-axis) the weight per unit area of the ceiling lining / suspended ceiling including grid and suspension can be read off from the y-axis at the intersection point with the marked diagonal [ kg/m ] weight of ceiling lining / suspended ceiling load class [ kN/m ]

y
65
60

0.50 < p 0.65 *) 55

50
45 0.30 < p 0.50 40 35

30
25 0.15 < p 0.30 20 0.15
*) design of ceilings 0.50 kN/m as well acc. to DIN 18168

15 11.5
10 45

x
9.5 12.5 15 18 20
(2x

25
5) 12.

30
15) (2x

33
(18 +15 )

40
(2x 20)

43
(25 +18 )

[ mm ]

thickness of cladding

2. Consideration of extra loads Extra loads from insulation required for fire protection and from insulation not required for fire protection (0.05 kN/m = 5 kg/m max.) as well as extra loads from system "Mulit-level Ceiling" (0.15 kN/m = 15 kg/m max.) increase the total weight per unit area of the suspended ceiling / ceiling lining and should be taken into account for the load class determination. The determined intersection point from the 1st step has to be parallel-shifted by the rate of the extra load in direction of the y-axis (upwards). 3. Determination of the load class The load class (kN/m) can be determined with the resulting total weight per unit area of the ceiling lining / suspended ceiling from steps 1 and 2. 4. Dimensioning the substructure Depending on fire protection requirements and load class the following spacings of the substructure are specified: without fire protection 1) fire protection from below 2)
spacings of suspenders / a anchors c spacings of carrying channels / timber battens normally dimensioned according to DIN 18168

fire protection from above (plenum) fire protection from below and from above
spacings of suspenders / anchors a have to be installed according to fire protection proofs

c spacings of carrying channels / timber battens b spacings of furring channels / timber battens

b 1) permissible span widths of spacings of furring channels / timber battens cladding acc. to DIN 18181 2) according to fire protection proofs normally use suspender 0.25 kN, for load class > 0.30 kN/m use suspender 0.40 kN.

suspenders and connectors according to fire protection proofs; Consider additionally required measures on pages 5 and 10.

D11 Knauf Board Ceilings


Knauf Boards / Span Widths of Cladding / Fastening of Cladding
Knauf Boards Board type General properties
easy few installation control joints

Building physics
fire protection sound protection statics / strength

Sophisticated applications
surface quality mitering molded technology areas

Knauf Diamant (hard gypsum board) GKFI *) Knauf Fireboard A1 (special board for fire protection) KNAUF Piano (sound shield) KNAUF Piano F (sound shield) Knauf Fire-Resistant Board Knauf Solid Board Knauf Panel Board Knauf Wallboard
unsuitable suitable

GKB GKF / GKFI *) GKF / GKFI *) GKF / GKFI *) GKF / GKFI *) GKB / GKBI *)
more suitable most suitable

*) GKBI and GKFI (impregnated) boards are most suited for humid rooms

Knauf 4AK Board


for optimized surface quality

GKF

4-side tapered edges filling of front edges and long edges with Joint Tape cross-mounting

Allowable span widths of cladding according to DIN 18181 Board thickness Maximum spacings of furring channel / timber batten b without fire protection
12.5 / 2x 12.5 15 18 20 Solid Board / Panel Board 25 Solid Board 500 550 625 625 800

all dimensions in mm

with fire protection


spacings of furring channels / timber battens acc. to pages 6 to 9

ball impact safety D112 / D113


Universal Bracket / Nonius suspension

single layer 250

double layer 2x 12.5 500

proof: PZ 46/902 967-2 + annex

Knauf Boards, fastening with Knauf Drywall Screws TN Cladding Thickness in mm


15 18 to 25 2x 12.5 2x 15 18 + 15 2x 20 / 25 + 18

spacing of screws 170 mm Wood frame minimum penetration 5 d n


(d n = nominal diameter) TN 3.5 x 35 mm TN 3.5 x 45 mm TN 3.5 x 35 mm + TN 3.5 x 45 mm TN 3.5 x 35 mm + TN 3.5 x 55 mm TN 3.5 x 45 mm + TN 3.5 x 55 mm -

Metal grid minimum penetration 10 mm Metal thickness s 0.7 mm


TN 3.5 x 25 mm TN 3.5 x 35 mm TN 3.5 x 25 mm + TN 3.5 x 35 mm TN 3.5 x 25 mm + TN 3.5 x 45 mm TN 3.5 x 35 mm + TN 3.5 x 45 mm TN 3.5 x 35 mm + TN 3.5 x 55 mm

Multi layer cladding

In case of multi layer cladding, apply layers with staggered joints according to application scheme. Press boards of each layer firmly on to the substructure and screw each layer separately. For fastening of first layer, spacing of screws can be increased up to max. 500 mm (for cladding thickness 25 + 18 mm/ 2x 20 mm up to max. 300 mm according to installation scheme on page 22) if second layer is applied immediately afterwards (within one working day). In case of multi layer cladding, a filling of joints of first layer without further finishing is sufficient.

board width 1250 1250

1st layer of boards

1250 1250

2nd layer of boards

board width

D11 Knauf Board Ceilings


Perimeter Spacings of Substructure / Height of construction
Perimeter spacings of substructure Option 1 non-bearing connection
scheme drawings, examples
( connection does not bear loads of the ceiling )

alle dimensions in mm

without perimeter joint covering covering with UD Runner as installation aid / in case of fire protection and sound protection, spacing of anchors of UD Runner up to approx. 1 m ca. 100 *)

ca. 150

ca. 150

ca. 100 *)

ca. 150

ca. 100 *)

ca. 100 *)

Option 2

bearing connection

The spacing of anchors of the UD Runner is reduced to 625 mm (use a dowel suitable for substrate). Carrying / furring channels should be inserted into bearing UD Runners for 20 mm min. Maximum allowable spacings (suspenders, carrying / furring channel) are given in tables of respective system.

b
20

a
20

c
20

screw spacing 170 mm screwing of cladding into UD Runner is necessary 100 170 170

ca. 100 *)

ca. 100 *)

ca. 100 *)

Notes

All connections of board ceilings can be installed according either to option 1 or option 2. Connection details on the following pages show: option 1 D111, D112, D116 option 2 D113

UD 28x27

additional screwing of cladding into UD Runner recommended (tight perimeter)

b
CD 60x27

a = spacing of suspenders (span width of carrying channels / timber battens) c = spacing of carrying channels / timber battens (span width of furring channels / timber battens) b = spacing of furring channels / timber battens (span width of cladding) *) max. cantilever of cladding height of construction = sum of suspension height, height of substructure and cladding thickness

Height of construction System Suspension


with Nonius Hanger Top
min. mm min. mm min. mm

Substructure
with wire
min. mm min. mm min. mm
Ceiling below Ceiling

Nonius Stirrup

Nonius Hanger Bottom

mm mm
Direct Bracket timber batten / channel bxh 50x30 + 50x30 50x30 + 40x60 60x27 60x27 + 60x27 60x27 UA 50x40 + CD 60x27 total height mm

Combo Hanger

Ankerfix Rapid Hanger

Combo Hanger

Rapid Wood Hanger

Universal Bracket

D111 D112 D113 D116

130 130

130 130 -

130 130 -

110 110 -

110 110 -

110 110 110 -

up to 180 up to 180 up to 180 -

mm

1 -

60 90 27 54 27 67

Calculation example

D112 with Nonius Hanger Bottom (130 mm), carrying channels and furring channels (54 mm) and cladding (2x 12.5 mm) = 209 mm approx. 210 mm required height of construction for suspended ceiling

D11 Knauf Board Ceilings


Suspensions, Load Bearing Capacity Classes According to DIN 18168-2
Ceiling below Ceiling Direct Bracket
for CD 60x27 bend side tabs anchoring to fire protection ceiling

Knauf All Purpose Screw FN 4.3x35 / FN 4.3x65


acc. to ABP P-VHT-1802/05-FN

0.25 kN (25 kg) load bearing capacity class Ankerfix


with lock for CD 60x27

Combo Hanger
for CD 60x27

Rapid Wood Hanger


for wood frames

suspended with

anchoring to wood joist ceiling

Hanging Wire

Knauf Flathead Screw FN 5.1x35 mm


acc. to ABZ Z-9.1-251

anchoring to concrete ceiling:

Knauf Ceiling Steel Dowel


acc. to ABZ Z-21.1-1519

0.40 kN (40 kg) load bearing capacity class


120 mm / 200 mm

Universal Bracket

for CD 60x27 / for timber batten 50x30 mm

anchoring to wood joist ceiling 2x Knauf TN 3.5x35 into tabs or 1x Knauf FN 5.1x35 in the middle acc. to ABZ Z-9.1-251 anchoring to concrete ceiling:

Cut and bend Universal Bracket according to required suspension height

0 mm m/5 60 m
for CD 60x27 for UA 50x40 / for timber batten 50x30 mm screwed with TN 3.5x25 at sides

Knauf Ceiling Steel Dowel


acc. to ABZ Z-21.1-1519

Nonius Stirrup

Bend Nonius Stirrup around channel and fit together until it snaps

suspended with

Nonius Hanger Top


and

135 mm

125 mm

Nonius Pin
(secure against sliding out)

as required

Nonius Connector

Nonius Hanger Bottom


for CD 60x27

Universal Connector
for CD 60x27

Combo Hanger
for CD 60x27

anchoring to wood joist ceiling

Knauf Flathead Screw FN 5.1x35 mm


acc. to ABZ Z-9.1-251 screw tabs to CD 60x27 (Metal Screws LN 3.5x9 mm) in case of: fire protection from above (plenum) fire protection from below and from above and / or total load of ceiling 0.4 kN/m

anchoring to concrete ceiling: in case of fire protection screw Universal Connector (used as suspender) to CD 60x27 (Metal Screws LB 3.5x9.5 mm)

Knauf Ceiling Steel Dowel


acc. to ABZ Z-21.1-1519

Note

Additional measures in case of

fire protection from above and from below fire protection from above (plenum) use fastener approved for fire protection Knauf ceiling steel dowel (mounted in accordance with ABZ Z-21.1-1519)

D11 Knauf Board Ceilings


Types of Basic Ceiling, Fire Protection from Below and from Above
Types of basic ceiling I to III
Ceilings with steel girders exposed to plenum with U/A ratio of 300 m -1 and top cover made of light concrete core panels according to DIN 4028 or aerated concrete slabs according to DIN 4223 Reinforced concrete beam ceilings according to DIN 1045 with intermediate units made of light concrete according to DIN 4158 or made of bricks according to DIN 4159 and DIN 4160 Ceilings made of reinforced concrete beams according to DIN 1045 with intermediate units made of light concrete according to DIN 4158 or bricks according to DIN 4159 and DIN 4160 Reinforced concrete ceilings in connection with embedded steel girders

Type I Type II

Ceilings with steel girders exposed to plenum with U/A ratio of 300 m -1 and top cover made of light concrete in-situ concrete according to DIN 1045 or precast slabs with static effective coat of in-situ concrete according to DIN 1045 or precast units as core panels made of reinforced or prestressed concrete Ceilings made of reinforced or prestressed standard concrete slabs but without units or intermediate units made of light concrete or bricks Reinforced or prestressed concrete slabs acc. to DIN 1045 resp. DIN 4227 made of standard concrete Reinforced concrete ceilings with beams and intermediate units acc. to DIN 1045 made of standard concrete Two-way flat slab and coffered ceilings according to DIN 1045 made of standard concrete

Type III

Reinforced or prestressed core panels acc. to DIN 1045 resp. DIN 4227 made of standard concrete Reinforced concrete beam ceilings acc. to DIN 1045 without intermediate units or with intermediate units made of standard conrete

Fire protection from below and from above (basic ceiling) Board ceilings in connection with basic ceilings type I to III Knauf System Basic ceiling type acc. to DIN 4102-4 II III I Knauf System constr. cladding
min. thickness
a a a

(see page 7)

Fire resistance class K215 / K218 Knauf Fireboard Ceilings A1 with metal grid

mm

mm

mm

Knauf Fireboard A1 (Z-PA-III 4.290)


25 20 15 25 20 15 12.5 20 15 12.5 15
not allowed not allowed not allowed 40 200 80 40 200 80 40 80

F90

S
not allowed not allowed not allowed

F90

400

S
not allowed not allowed

F90

Note

Spacings of suspenders and of carrying channels as well as installation and application according to Data Sheet K21 Knauf Fireboard Ceilings A1

Proof (see page 7)


7

substructure max. spacing of furring channels b

Mineral wool insulation in plenum

Minimum plenum height between basic ceiling and cladding -a-

D11 Knauf Board Ceilings


Fire Protection from Below and from Above (Basic Ceiling)
Board ceilings in connection with basic ceilings type I to III Knauf System Basic ceiling type acc. to DIN 4102-4 I II III Knauf System constr. cladding
min. thickness
a a a

Fire resistance class D112 / D116 Knauf Board Ceilings with metal grid F30

mm

mm

mm

Knauf Fire-Resistant Boards GKF A2


20 15
not allowed without / G not allowed not allowed 40 40 40 40 40 80 40 80 80 40 80 80 40 80 80 80

F30

20 12.5 15 20 12.5 15 12.5 2x 15 25 (2x 12.5) 20 (2x 12.5) 25 (2x 12.5) 25 (2x 12.5) 20 (2x 12.5) 15 20 (2x 12.5) 20 15 12.5 15 15

500

G
not allowed not allowed

F30

G G
not allowed not allowed not allowed

F60

S 400
resp. not allowed not allowed not allowed

F60

500
(in case of double layer cladding)

S
not allowed not allowed not allowed

F60

S 500
not allowed

F90 Note

Spacings of suspenders (anchors) and spacings of furring channels according to tables of respective system all dimensions in mm

Max. spacings single grid (only furring channels) Grid

Spacings of suspenders / anchors a load class kN/m 0.15 0.30


1250 1000 1200 950

Collared Resilient Channel 98x15x0.6 for flat ceilings

CD 60x27 Collared Resilient Channel 98x15

Mineral wool insulation according to DIN EN 13162, chapter 3.1.1


building material class A S melting point 1000 C acc. to DIN 4102-17 thickness 50 mm, density 40 kg/m G building material class A

Proofs 7 8 ABP P-3155/3992 DIN 4102-4, chapter 6.5.5, table 99

Proof
7 7 8

substructure max. spacings of furring channels b

Mineral wool insulation in plenum


(see page 7)

Minimum plenum height between basic ceiling and cladding -a-

D11 Knauf Board Ceilings


Fire Protection from Below and / or from Above (Plenum)
Board ceilings with sole fire protection Requirement to basic ceiling in case of fire stress: from below
no fire protection requirements for basic ceiling / roof

Fire resistance class in case of fire stress

Knauf System construction cladding


type/ building material class min.

substructure
max. spacings

insulation
required for fire protection

thickness

from above (plenum)


basic ceiling should be of same fire resistance class as suspended ceiling

from below

from above

carrying channels/ timber battens min. b thickness


mm mm mm

min. denisty kg/m

D111 Knauf Board Ceiling with wood frame 20 F30


Fire-Resistant Boards GKF, A2

625 500 500


-

2x 12.5 18 + 15

F60 D112 Knauf Board Ceiling with metal grid

20 F30 2x 12.5 F60


Fire-Resistant Boards GKF, A2

625 500 500


-

18 + 15 2x 20

F90 25 + 18 F30 15 18 F30 F30


Fire-Resistant Boards GKF, A2

500

500 625 500 500

mineral wool S 40 (60) + mineral wool S 40 (60) 150 mm wide 40 (30) 40 (30)

2x 12.5 18 + 15 2x 20

F60

F60

on carrying channels

F90

F90 25 + 18

500

mineral wool S 2x 40 (60) 40 (30)

D113 Knauf Board Ceiling with flush metal grid 18 F30


Fire-Resistant Boards GKF, A2

500 500 400 400


-

mineral wool G 40 -

2x 12.5 18 + 15 25 + 18

F60 F90
Mineral wool insulation acc. to DIN EN 13162, chapter 3.1.1

building material class A S melting point 1000 C acc. to DIN 4102-17

building material G class A

Note Proof

Spacings of suspenders and of carrying channels acc. to table of respective system or in case of fire protection from above acc. to page 10 ABP P-3400/4965

D11 Knauf Board Ceilings


Fire Protection from Below and / or from Above (Plenum)
Board ceilings with sole fire protection Requirement to basic ceiling in case of fire stress: from below
no fire protection requirements for basic ceiling / roof consider notes on page 8

Fire resistance class in case of fire stress

Knauf System construction cladding


type/ building material class min.

substructure
max. spacings

insulation
required for fire protection

thickness

from above (plenum)


basic ceiling should be of same fire resistance class as suspended ceiling

from below

from above

carrying channel
b
mm mm min. thickness mm min. denisty kg/m

D113 Knauf Board Ceiling with flush metal grid F30 15 18 F30 F30
Fire-Resistant Boards GKF, A2

500

500 2x 12.5 18 + 15 25 + 18 400 400

mineral wool S 40 (60) 40 (30)

F60 F90

F60 F90

mineral wool S 2x 40 (60) 40 (30)

F30
Universal Connector

F30

Fire-Resistant Boards GKF, A2

2x 12.5

500

D116 Knauf Board Ceiling with metal grid UA / CD 20 F30 2x 12.5 F60
Fire-Resistant Boards GKF, A2

625 500 500


-

18 + 15 2x 20

F90 25 + 18 F30 15 18 F30 F30


Fire-Resistant Boards GKF, A2

500

500 625 500 500


mineral wool S 40 (60) 40 (30) + mineral wool S 40 (60) 40 (30)

2x 12.5 18 + 15 2x 20

F60

F60

150 mm wide

F90 Ceiling below Ceiling F30 F60 F90

F90 25 + 18

500

on carrying channel

fire protection ceiling solely from below D112, D116 + exposed ceiling (e.g. Cleaneo Acoustic Design Ceiling) 0.15 kN/m

D11 Knauf Board Ceilings


Fire Protection Solely from Above / Solely from Below and from Above (Plenum)
Maximum grid spacings fire protection from above
Spacings of carrying channel c
mm

Spacings of suspenders type a


mm

Fire resistance class


for fire protection

Mineral wool
min. thickness mm

S
min. density kg/m

required for fire protection

from above
(from the plenum)

scheme drawings

D112 Knauf Board Ceiling with metal grid


150 mm
Nonius Stirrup, Universal Bracket, Nonius Hanger Bottom 40 (60) 40 (30) 150 mm wide on carrying channel 40 (60) 40 (30)

850

750

F30 to F60

750

600

Nonius Stirrup, Universal Bracket, Nonius Hanger Bottom

F90

40 (60) 40 (60)

40 (30) 40 (30)

D113 Knauf Board Ceiling with flush metal grid

1250

650

Universal Connector

F30

1250

650

Nonius Hanger Bottom, Universal Bracket

F30 to F60
40 (60) 40 (30)

1250

500

Nonius Hanger Bottom, Universal Bracket

40 (60)

40 (30) 40 (30)

F90

40 (60)

D116 Knauf Board Ceiling with metal grid UA / CD


1200 1200 800 1200 1000 800
Nonius Stirrup Nonius Stirrup threaded rod M8 threaded rod M8

F30 to F60

40 (60) 40 (30) 150 mm wide on carrying channel 40 (60) 40 (30)

150 mm

F90

Further data on pages 8 to 9


thickness / type of cladding spacings of furring channels b mineral wool S

Additional constructional measures Flush Connector for CD 60x27: Nonius Hanger Bottom:
bend tabs and screw to lower channel (Metal Screws LN 3.5 x 9 mm) screw tabs to CD 60x27 (Metal Screws LN 3.5 x 9 mm) (Metal Screws LB 3.5 x 9.5 mm)

Universal Connector as suspender: screw to CD Channel 60x27 anchoring to basic ceiling:


use anchor approved for fire protection Knauf Ceiling Steel Dowel (mounted in accordance with ABZ Z-21.1-1519)

10

D11 Knauf Board Ceilings


Connections
Connections of light-weight partitions to classified susepnded ceilings
Connections of partitions to classified ceilings (board ceilings) are only allowed if it is ensured that in case of fire and a premature collapse of the partition, the debris pieces of the partition may fall down without additional loading of the ceiling. The following solutions are optional for the connection:
scheme drawings

Fire protection from below


For suspended ceilings with fire protection from below do not fasten cladding to UW runner, but apply cladding tightly up to ceiling.

Fire protection from below and from above / from above


For suspended ceilings with fire protection from below and from above / from above install a deflection head as standard implementation with at least 15 mm allowable movement.

no fastening to UW Runner

connection to board ceiling as deflection head

no fastening to UW Runner

BSU

BSO

Note

In case of fire protection requirements for the partition the suspended ceiling should have at least the same fire resistance.

Fire protective connections to walls


Suspended ceilings in connection with basic ceilings of type I to III as well as suspended ceilings for fire protection solely from below and / or from above that are fire rated F30 to F90 can be connected to partitions if they are of the same fire resistance class. Surface of partition should be even in the area of the connection. Specific levelling preparations might be necessary. The connection of the board ceiling has to be tight and covered.

board strip

Fire-Resistant Board

mineral wool melting point 1000 C

Fire-Resistant Board filler a F30 / F60: a 10 mm F90: a 20 mm

Fire-Resistant Board filler

Fire-Resistant Board filler

BSA 1

BSA 2

BSA 3

board strips

Fire-Resistant Board filler

Fire-Resistant Board

BSA 5

BSA 6

11

D11 Knauf Board Ceilings


Multi-level Ceiling
Exposed ceiling below fire protection ceiling

a
spacing of suspenders of exposed ceiling

fire protection ceiling Knauf Board Ceiling D112, D116


see fire protection survey on pages 8 to 9

F30 to F90
proof: see page 8

solely from below

2 2
ch an ne ls

exposed ceiling 0.15 kN/m


e.g. Cleaneo Acoustic Design Ceiling (installation acc. to D12) in case of exposed ceilings made of metal suspension height should be 150 mm min.

b
spacing of furring channels

1 Grid spacings fire protection ceiling


The additional load of the suspended ceiling (exposed ceiling 0.15 kN/m) has to be considered for the substructure of the fire protection ceiling (see also page 2 "Dimensioning of substructure"). The spacings of the substructure of the fire protection ceiling are given by the specifications of the respective system ceiling (e.g. D112) under consideration of the additional load of the exposed ceiling.

sp ac

2 Maximum spacings for exposed ceiling


Spacings of carrying channels c 800 1000 1200

in g

of c

ar

ry in g

all dimensions in mm

Spacings of suspenders *) Spacings of furring channels load class kN/m b a 0.15 800 **) 400 / 500 400 / 500 500
(for Cleaneo Acoustic Ceilings see D12)

*) Fasten only to furring channels of fire protection ceiling. **) Fasten alternating to every second furring channel of the fire protection level if spacing of furring channels (fire protection level) is 400 mm.

Fasten to every furring channel of fire protection level if spacing of furring channels (fire protection level) is 500 / 625 mm.

Detail scale 1:5 D112-D112


Knauf Multi-level Ceiling
Nonius Hanger Top carrying channel CD 60x27 furring channel CD 60x27 Knauf Boards GKF Nonius Pin Nonius Stirrup 0.40 kN for CD 60x27

alternative suspension: Direct Bracket


see page 5 and Data Sheet D12 Knauf Cleaneo Acoustic Ceilings

Knauf Board

Universal Bracket for CD 60x27 Knauf All Purpose Screw FN 4.3x35 / FN 4.3x65 (acc. to ABP P-VHT-1802/05-FN)

Notes

12

install suspended channels of exposed ceiling always laterally to furring channels of fire protection ceiling max. load per suspension of exposed ceiling: 100 N

D11 Knauf Board Ceilings


Sound Protection following DIN 4109 Supplement 1 and 2
Longitudinal sound reduction index R L,w,R Board ceilings with non-perforated surface
Suspension height 400 mm

Cladding

Rated longitudinal sound reduction indices R L,w,R in dB without mineral wool full area layer of mineral wool 40 mm 80 mm

Examples of application

mm

Connection of partition to suspended ceiling, continuous cladding

single layer 12.5 mm

46

47

48

double layer 2x 12.5 mm

53

54

54

Connection of partition to suspended ceiling, cladding separated

single layer 12.5 mm

48

52

54

double layer 2x 12.5 mm


400 mm

55

57

57

Connection of partition to suspended ceiling, cladding separated with absorbent bulkhead *) 400 mm

single layer 12.5 mm

60

Connection of partition to solid basic ceiling, with separation of suspended ceiling at cladding and construction

double layer 2x 12.5 mm

55

63

Separation of plenum by bulkhead made of boards

single layer 12.5 mm

65

Connection of partition to solid basic ceiling (the cladding up to the solid ceiling is effective as separating bulkhead of the plenum)

single layer 12.5 mm

65

*) absorbent bulkhead made of mineral wool acc. to DIN EN 13162, length related flow resistance value r 8 kPa s/m Note
In case of suspension height of more than 400 mm the values should be reduced by 1 dB.

13

D111 Knauf Board Ceiling


Wood Frame
Carrying battens and furring battens / Universal Bracket

ca. 250

a
spacing of suspenders
(anchors)

ca. 100

sp ac

in

of

ca rry c in g ba tte ns

(5

spacing of furring battens (50x30 mm)

Max. spacings of substructure without fire protection fire protection from below

all dimensions in mm

Fastening Carrying / furring batten

c Spacings of carrying battens

Spacings of suspenders / anchors load class kN/m (see page 2) 0.30 0.15 1200 1150 1050 1050 1000 950 900 900 950 900 850 800 800 2)

a
0.50 800 750 700 2) 1)

500 600 700 800 900 1000 1100 1200

fastening of furring battens 50x30 mm to carrying battens 50x30 mm with

Knauf Drywall Screws TN 4.3x55


acc. to ABZ Nr. Z-9.1-251

Further construction information without fire protection:


spacing of furring battens page 3

1) use suspenders of load capacity class 0.40 kN 2) not valid for spacing of furring battens of 800 mm

with fire protection:


spacings of furring battens and type / thickness of cladding page 8

14

Note

A customized dimensioning of the ceiling substructure is possible on request (e.g. for different batten dimensions).

0x 30
perimeter

option 1
see also page 4

mm

c 15 a. 0

D111 Knauf Board Ceiling


Wood Frame

Direct anchoring / Universal Bracket 0.40 kN

Rapid Wood Hanger 0.25 kN

longitudinal joint

2x Knauf Drywall Screws TN 3.5x35

cut edge joint


carrying batten 40x60 mm (bxh)

longitudinal joint
alternate side of fastening

cut edge joint

Details scale 1:5 D111-A1


Connection to wall with dry lining

D111-D2

Connection to wall with dry lining

furring batten 50x30 (bxh) Knauf Board filler + Trenn-Fix 65

fasten Universal Bracket for wood batten with 2x Knauf Drywall Screws TN 3.5x25 to batten Knauf Ceiling Steel Dowel carrying batten

Knauf Drywall Screws TN 4.3x55 installation aid, required in case of fire protection as covering according to page 11 plaster or dry lining, fully filled with mortar at connection area in case of fire protection fastener suitable for substrate, spacing up to approx. 1 m

D111-B1

Longitudinal joint

D111-C1

Cut edge joint

carrying batten furring batten 50x30 (bxh)

Knauf Uniflott Drywall Screw TN 3.5x45 Panel Board 20 mm, width 625 mm

Knauf Board Drywall Screw TN Knauf Uniflott + Joint Tape

anchoring with fastener approved for building material carrying batten furring batten 50x30 (bxh)

15

D112 Knauf Board Ceiling


Metal Grid
Carrying channels and furring channels / suspended

ca. 250

a
spacing of suspenders
(anchors)

ca. 100

sp ac in g

of c ca rry in g

spacing of furring channels

Maximum grid spacings without fire protection fire protection from below

alle dimensions in mm

Channel connections Carrying channel to furring channel Intersection Connector for CD 60x27
bend to 90 before installation

c Spacings of carrying channel

Spacings of suspenders

load class kN/m (see page 2) 1) 0.30 0.50 0.15 1200 1150 1100 1050 1000 950 900 900 950 900 850 800 800 750 750 2)

only Ceiling below Ceiling F90 1) 0.65 750 700

500 600 700 800 900 1000 1100 1200

800 750 700 700 2) 2)

650 -

alternative 2x Clip for CD 60x27

bend during installation

Further construction information without fire protection:


spacing of furring channels page 3

with fire protection:


spacings of furring channels and type / thickness of cladding max. grid spacings (fire prot. from above) pages 7 to 8 page 10

1) use suspenders of load capacity class 0.40 kN 2) not valid for spacing of furring channels of 800 mm

Notes

16

A customized dimensioning of the ceiling substructure is possible on request. It is recommended to dimension the substructure considering a possibly additional ceiling ( 0.15 kN/m).

ch an ne
perimeter

ls

option 1
see also page 4

c 15 a. 0

D112 Knauf Board Ceiling


Metal Grid

Universal Bracket 0.40 kN

suspended, e.g. with Nonius Suspension 0.40 kN

longitudinal joint

cut edge joint suspension options: cut edge joint


Ankerfix Rapid Hanger 0.25 kN Nonius Suspension 0.40 kN Nonius Stirrup 0.40 kN

longitudinal joint
Combo Hanger - with wire 0.25 kN - with Nonius Hanger Top 0.40 kN

Details scale 1:5 D112-A2


Connection to wall

D112-D2

Connection to wall

Knauf Board filler + Trenn-Fix 65

furring channel CD 60x27 carrying channel CD 60x27 fasten Universal Bracket with Metal Screws LN 3.5x9 mm to carrying channel

Clip for CD 60x27 UD Runner 28x27 optional as installation aid, required for fire protection as covering according to page 11 fastener suitable for substrate, spacing up to approx. 1 m

D112-B2

Longitudinal joint

D112-C2

Cut edge joint

Knauf Ceiling Steel Dowel carrying channel CD 60x27

Knauf Board Drywall Screw TN Knauf Uniflott

Drywall Screw TN Knauf Uniflott + Joint Tape

Universal Bracket furring channel CD 60x27 Intersection Connector scheme drawings

Knauf 4AK Board

filler + Joint Tape

filler + Joint Tape

board joints with 4-side tapered edges

Knauf 4AK Board cross mounting (staggering of joints not necessary) filling with Joint Tape

17

D112 Knauf Board Ceiling


Metal Grid
Details scale 1:5 D112-A1
Connection to wall

D112-D3

Connection to wall

ca. 150 mm

c
Nonius Pin Nonius Hanger Bottom for CD 60x27 Intersection Connector for CD 60x27 carrying channel CD 60x27

ca. 250 mm
Nonius Hanger Top Nonius Pin Nonius Hanger Bottom for CD 60x27

filler + Trenn-Fix 65 furring channel CD 60x27 fastener suitable for substrate, spacing up to approx. 1 m plaster or dry lining, fully filled with mortar at connection area in case of fire protection

furring channel CD 60x27 Intersection Connector carrying channel CD 60x27 Knauf Board UD Runner 28x27 optional as installation aid, required for fire protection as covering according to page 11

D112-B4

Longitudinal joint

D112-C4

Cut edge joint

Knauf Ceiling Steel Dowel Hanging Wire Ankerfix Rapid Hanger Intersection Connector for CD 60x27

Hanging Wire Ankerfix Rapid Hanger Clip for CD 60x27

furring channel CD 60x27 carrying channel CD 60x27

Knauf Boards Drywall Screw TN Knauf Uniflott

Knauf Board Knauf Uniflott + Joint Tape

carrying channel CD 60x27 furring channel CD 60x27

D112-B5

Longitudinal joint

D112-C1

Cut edge joint

Knauf Ceiling Steel Dowel Nonius Hanger Top Nonius Pin Nonius Stirrup for CD 60x27 Clip for CD 60x27 Intersection Connector for CD 60x27

Nonius Hanger Top Nonius Stirrup for CD 60x27 Nonius Pin

furring channel CD 60x27 carrying channel CD 60x27

Knauf Uniflott Drywall Screw TN 3.5x35 Panel Board 20 mm, width 625 mm

Knauf Boards Drywall Screw TN

carrying channel CD 60x27 furring channel CD 60x27

18

D112 Knauf Board Ceiling


Metal Grid
Details scale 1:5 D112-A5
Vertically sliding connection to wall
option 1

D112-D5

Vertically sliding connection to wall


option 2 Nonius Hanger Top

Nonius Pin Nonius Hanger Bottom for CD 60x27 Intersection Connector for CD 60x27 carrying channel CD 60x27

Noniussplint Nonius Hanger Bottom for CD 60x27

Clip for CD 60x27 Knauf Board Knauf Board strip filler + Trenn-Fix 65

furring channel CD 60x27

Knauf Board furring channel CD 60x27 Joint Tape Drywall Screw TN mitered board

Sliding connections are suitable for fire resistance F30 as well.

D112-B6

Connection of partition to board ceiling

D113-B4

Connection of partition to board ceiling

diagonal bracing with slot strap

filler + Trenn-Fix 65 Acoustical Sealant

full area mineral wool layer thickness 40 mm UW Runner Knauf All Purpose Screw FN screwed into CD Channel

Knauf Uniflott + Trenn-Fix 65 cavity dowel or Knauf All Purpose Screw FN screwed with CD Channel UW Runner for connections of "lightweight" partitions to fire protective classified suspended ceilings see page 11.

cladding separated at connection: rated longitudinal sound reduction index R L,w,R 52 dB

D112-A3

Connection to wall with exposed joint ca. 150 mm

D112-A4

Connection to wall with exposed joint ca. 150 mm

c
Nonius Pin Nonius Hanger Bottom for CD 60x27 Intersection Connector for CD 60x27

Nonius Pin Combo Hanger for CD 60x27 with Nonius Hanger Top Intersection Connector

carrying channel CD 60x27 furring channel CD 60x27 Edge Trim (if necessary) e.g. U Perimeter Profile 28x27x48 fastener suitable for substrate, spacing up to approx. 1 m

Edge Trim furring channel CD 60x27 (if necessary) carrying channel CD 60x27 UD Runner 28x27 optional as installation aid

19

D113 Knauf Board Ceiling


Flush Metal Grid
Flush metal grid with carrying channel as long channel and furring channels as cross channels / suspended

a
spacing of suspenders
(anchors)

a
spacing of suspenders
(anchors)

sp ac

in

of

lo

b
spacing of cross channels

Maximum grid spacings without fire protection fire protection from below Spacing of long channels Spacings of suspenders a load class kN/m (see page 2) 0.15 1100 1250 650 0.30 650 0.50
1)

all dimensions in mm

Channel connections Long channel to cross channel, flush Flush Connector for CD 60x27

Spacings of cross channels

b
500 400

1) use suspenders of load capacity class 0.40 kN

for additional measures for fire protection from above see page 10.

Universal Connector as suspender

Universal Connector for CD 60x27


as suspender with Nonius Hanger Top 0.40 kN screw to CD Channel in case of fire protection predetermined folding point

optional folding point delivered unbent adjust roughly, depending on use adjust correctly during assembly

Further construction information with fire protection:


spacings of cross channels and type/ thickness of cladding max. grid spacings (fire prot. from above) page 8 to 9 page 10

20

Note

A customized dimensioning of the ceiling substructure is possible on request.

ng

ch

perimeter

option 2
In case of D113 bearing UD Runner at entire perimeter, see also page 4

an ne

ls

<

12

20

D113 Knauf Board Ceiling


Flush Metal Grid

Universal Bracket 0.40 kN

Suspended, e.g. with Nonius Suspension 0.40 kN

Nonius Hanger Top with Nonius Hanger Bottom cross channel, length 1190 mm

Nonius Hanger Top

Nonius Connector Nonius Pin Universal Connector as suspender with Nonius Hanger Top Nonius Hanger Top M6 / 16 mm

longitudinal joint

cut edge joint suspension options


Ankerfix Rapid Hanger 0.25 kN Nonius Suspension 0.40 kN Combo Hanger - with wire 0.25 kN - with Nonius Hanger Top 0.40 kN

longitudinal joint
Universal Connector as suspender with Nonius Hanger Top 0.40 kN

long channel, continuous

cut edge joint

Details scale 1:5 D113-A2


Connection to wall
(load-bearing)

D113-D2

Connection to wall

(load-bearing)

< 1220 mm
to center of long channel

a
spacing of suspenders

cross channel CD 60x27, length 1190 mm

cross channel CD 60x27 Flush Connector for CD 60x27

screwing of cladding with UD Runner required screw spacing 170 mm fastener suitable for substrate,

spacing 625 mm
plaster or dry lining fully filled with mortar at connection area in case of fire protection

UD Runner 28x27 long channel CD 60x27 screwing of cladding with UD Runner required screw spacing 170 mm fastener suitable for substrate,

spacing 625 mm

spacing of cross channel

D113-B2

Longitudinal joint

D113-C2

Cut edge joint

Knauf Boards screw Universal Bracket with Metal Screws LN 3.5x9 to long channel

cross channel CD 60x27, length 1190 mm long channel CD 60x27 Knauf Ceiling Steel Dowel

Flush Connector for CD 60x27 long channel CD 60x27 cross channel CD 60x27, length 1190 mm

Knauf Board Drywall Screw TN Knauf Uniflott + Joint Tape

c
spacing of long channel

c
spacing of cross channels

21

D112/D113 Knauf Board Ceilings


Fire Resistance F90
D112 F90

solely from below


installation scheme

solely from below see also page 8

dimensions in mm

1st layer
2nd layer 1st laer
Solid Board GKF 25 mm, width 625 mm

or

2x 20 mm Fastening screws
Knauf Drywall Screws Spacing of screws

2nd layer
Fire-Resistant Board GKF 18 mm, width 1250 mm

1st layer: TN 3.5x35 300 mm *) 2nd layer: TN 3.5x55 170 mm *) min. 3 screws per board width

ca.150

c c c c see page 16 spacing of carrying channels

for spacings of suspenders see page 16 dimensions in mm

D113 F90

solely from below see also page 8

installation scheme

25 + 18 mm

Fastening screws
Knauf Drywall Screws Spacing of screws

Solid Board GKF 25 mm, width 625 mm (installed with long channel at center line)

2nd layer
Fire-Resistant Board GKF 18 mm, width 1250 mm 1250 1250 1250

1st layer: TN 3.5x35 300 mm *) 2nd layer: TN 3.5x55 170 mm *) min. 3 screws per board width

< 1220

spacing of long channels

for spacings of suspenders see page 20

Details scale 1:5 D112F90vu-D2


Connection to wall
Nonius Hanger Bottom screwed with Metal Screw LN 3.5 x 9 mm to carrying channel

D112F90vu-B1

Longitudinal joint

carrying channel CD 60x27

UD Runner 28x27 as covering for fire protection, see page 11 fastener suitable for substrate, spacing up to approx. 1 m

furring channel CD 60x27 Drywall Screw TN 3.5x55

Solid Board GKF 25 mm Fire-Resistant Board GKF 18 mm Knauf Uniflott

D113F90vu-D3

Connection to wall (load-bearing)

D113F90vu-B3

Longitudinal joint

a
spacing of suspenders fastener suitable for substrate, cross channel CD 60x27

spacing 625 mm

screwing of cladding with UD Runner required screw spacing 170 mm

22

400 mm spacing of cross channels

cross channel CD 60x27 length 1190 mm long channel CD 60x27

Solid Board GKF 25 mm Fire Resistant Board GKF 18 mm Drywall Screw TN 3.5x35

spacing of cross channels

1st layer
2nd layer 1st layer

400 400 400 400 400 400 400 400

Cladding GKF

spacing of furring channels

25 + 18 mm

500 500 500 500 500 500

Cladding GKF
ca. 100

D11 Knauf Board Ceilings


Connections to Walls / Settlement Joints
Details scale 1:5 D111-D8
Connection to wall with shadow gap
fire protection design all dimensions in mm

D112-D4

Connection to wall with shadow gap


fire protection design

2x Knauf Drywall screw TN 3.5x35 carrying batten 40x60 (bxh)

Hanging Wire Rapid Wood Hanger alternate fastening side

carrying channel CD 60x27 furring channel Clip for CD 60x27

Knauf Board strip GKF Edge Trim (if necessary) wood batten 30x50 (bxh) fastener suitable for substrate, spacing up to approx. 1 m

Knauf Board strip GKF Edge Trim (if necessary) UD Runner 28x27x0.6 fastener suitable for substrate, spacing up to approx. 1 m plaster or dry lining fully filled with mortar at connection area in case of fire protection

25 20 mm 20 mm Settlement joint
fire protection design

25 20 mm 20 mm

D111-C3

D112-C3

Settlement joint
fire protection design

Knauf Board GKF Edge Trim 23x13 (if necessary)

glue Knauf Board strip GKF with Fugenfller Leicht at one side

> 25 >a a

> 25

a 20 mm

glue Knauf Board strip GKF with Fugenfller Leicht at one side Edge Trim 23x13 (if necessary)

ca. 100 mm >25 a >25 a >25 >a

a 20 mm

D113-C4

Settlement joint
fire protection design

glue Knauf Board strip GKF with Fugenfller Leicht at one side Edge Trim 23x13 (if necessary)

ca. 100 mm >25 a >25 a >25 >a

Universal Connector for CD 60x27 CD 60x27 continuous

a 20 mm

23

D116 Knauf Board Ceiling


Metal Grid UA / CD
Carrying channel UA + furring channel CD / suspended

ca. 250

a
spacing of suspender
(anchors)

ca. 100

sp ac

in

of

ca rry in g

spacing of furring channel

Maximum grid spacings 1) without fire protection fire protection from below Spacing of carrying channels Spacings of suspenders a Nonius Stirrup (0.40 kN) load class kN/m (see page 2) 0.15 0.30 0.50 2600 2450 2300 2200 2150 2050 2000 1950 1900 1850 1750 2050 1950 1850 1650 1450 1300 1200 2)

alle dimensions in mm

Channel connection Carrying channel UA to furring channel CD

c
500 600 700 800 900 1000 1100 1200 1300 1400 1500

only Ceiling below Ceiling F90 0.65 1200 1000

Intersection Connector for UA Profile

1600 1300 1100 1000 2) 2)

850 -

bend to 90 before installation

Further construction information without fire protection:


spacing of furring channels page 3

with fire protection:


spacings of furring channels and type / thickness of cladding max. grid spacings (fire prot. from above) pages 7 + 9 page 10

1) spacing of suspenders max. 1700 mm 2) not valid for spacing of furring channels of 800 mm
A customized dimensioning of the ceiling substructure is possible on request. It is recommended to dimension the substructure considering a possibly additional ceiling ( 0.15 kN/m).

Notes

24

ch an ne l
perimeter

option 1
see also page 4

c 15 a. 0

D116 Knauf Board Ceiling


Metal Grid UA / CD
Details scale 1:5 D116-A1
Connection to wall ca. 150 mm

D116-D1

Connection to wall ca. 250 mm

Nonius Hanger Top Nonius Stirrup for UA 50x40 Nonius Pin Intersection Connector for UA 50x40 carrying channel UA 50x40

Nonius Hanger Top Nonius Stirrup for UA 50x40 Nonius Pin carrying channel UA 50x40

UD Runner 28x27 furring channel CD 60x27 filler + Trenn-Fix 65 Knauf Board fastener suitable for substrate spacing up to approx. 1 m

Drywall Screw TN UD Runner 28x27 optional as installation aid, required for fire protection as covering according to page 11 filler + Trenn-Fix 65

ca. 100 mm

D116-B1

Longitudinal jojnt

D116-C1

Cut edge joint

Knauf Ceiling Steel Dowel Nonius Hanger Top

Knauf Ceiling Steel Dowel Nonius Hanger Top Nonius Stirrup for UA 50x40 Nonius Pin

Nonius Pin Nonius Stirrup for UA 50x40 Intersection Connector for UA 50x40

carrying channel UA 50x40 Intersection Connector for UA 50x40

furring channel CD 60x27 carrying channel UA 50x40

Knauf Boards Drywall Screw TN Knauf Uniflott

furring channel CD 60x27

Knauf Board Drywall Screw TN Knauf Uniflott + Joint Tape

ca. 200 mm

extension of UA Profiles with UW Profile 50x40


UW Profile 50x40x0.6 Metal Screw LB 3.5x16 UA Profile 50x40x2.0 furring channel CD 60x27

25

D11 Knauf Board Ceilings


Special Details
Details scale 1:5 Ceiling bulkhead
application according to Technical Data Sheet D16 Knauf Ceiling Built-ins

Drywall Screw TN

Uniflott Acoustical Sealant UW Runner

Knauf Ceiling Steel Dowel a 1.0 m


Knauf Board Knauf CW Stud insulation UW Runner

Hhe -H-

Cladding of bulkhead

Height -H- Knauf Board


m mm

1.40 1.00

12.5 2x 12.5

If spacing of Ceiling Steel Dowel is reduced by 50 %, allowable heights may be doubled

Drywall Screw TN

Knauf Board

rivet UW Runner with Knauf CW Stud

250 mm

250 mm
application according to Technical Data Sheet D19 Knauf Designed Ceilings

Split level ceiling 45

Multi Connector for CD 60x27

Multi Connector with adapters 135


CD 60x27 Drywall Screw TN 3.5x25 Drywall Screw TN Knauf Board with 45 miter

Multi Connector Adapter adapter e.g. 135

Knauf Board

Multi Connector with adapters 135


(shorten connector if necessary) for more adapters see Data Sheet D19 application according to Technical Data Sheet K736 Knauf LaVita Shielding Boards

LaVita Shielding Boards


Shielding:

high frequency electromagnetic waves / electrical alternating fields of low frequency

Conduction and by-pass of partition and plenum LaVita Arrester Plate grounding via potential equalization LaVita Shielding Board 12.5 mm Knauf All Purpose Screw FN 4.3x35, screwing into metal stud LaVita Arrester Plate conductive side LaVita Shielding Board 12.5 mm covering of cut edge joint with conductive side LaVita Shielding Board

LaVita By-pass Plate


conductive connection in longitudinal direction of LaVita Shielding Boards

Reference for more information

26

D12 Knauf Cleaneo Acoustic Ceilings / D15 Knauf Wood Joist Ceilings / D16 Knauf Ceiling Built-ins ( e.g. access panels, illuminations, ceiling bulkhead)

D11 Knauf Board Ceilings


Consumption of Material of selected Examples
Consumption of material per m ceiling without allowance for loss and waste. Description
italic = not provided by Knauf Amounts refer to ceiling area of: 10 m x 10 m = 100 m

Unit

Amount as average value D111 D113 1 2 1


0.4 0.4 0.4 0.4 0.4 0.7

2
0.4 0.7

3
0.4 0.7

connection to wall
UD Runner 28x27x0.6; length 3 m fastener approved for substrate e.g. Knauf Ceiling Steel Dowel for reinforced concrete m pcs

substructure
alt. Knauf Ceiling Steel Dowel (for reinforced concrete) approved fastener pcs 1.3 1.3 2.6 1.3 1.3 2.6 1.2 2.1 2.5
as req.

2 2 4 2 2 4 1.5 2.1 3.2


as req.

0.7 0.7 1.4 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 1.4 0.7 1.4 0.8 0.2 1.9 1.5 3 as req.

1.2 1.2 2.4 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 2.4 1.2 2.4 2.4 0.8 0.2 1.9 1.5 3 as req.

1.2 1.2 2.4 1.2 1.2 1.2 2.4 0.8 0.2 1.9 1.5 6 1 1 27 0.4 0.35 0.45 0.45

Universal Bracket for CD 60x27 Metal Screws 2x LN 3.5x9 mm (fastening to CD Channel) alt. Universal Bracket for timber batten 50x30 Knauf Drywall Screws 2x TN 3.5x25 mm (screwing to batten) or Hanging Wire Ankerfix Rapid Hanger for CD 60x27 alt. Combo Hanger for CD 60x27 alt. Rapid Wood Hanger Knauf Drywall Screws 2x TN 3.5x35 mm (screwing to batten) or Nonius Hanger Top Nonius Pin Nonius Hanger Bottom for CD 60x27 Metal Screws 2x LN 3.5x9 mm (screwing to CD Channel) alt. Combo Hanger for CD 60x27 alt. Universal Connector (as suspender) M 6 / 16 2x Nonius Hanger Top Nonius Connector 2x Nonius Pin Metal Screws 2x LB 3.5x9.5 mm CD Channel 60x27x0.6; length 4 m Multi-Connector (as longitudinal connection for CD Channels) CD Channel 60x27x0.6; length 1.19 m Flush Connector for CD 60x27 Metal Screws 4x LN 3.5x9 mm (screwing to CD Channel) alt. Universal Connector

pcs

pcs

pcs

m pcs m pcs

m carrying batten 50x30 mm m furring batten 50x30 mm Knauf Drywall Screw TN 4.3x55 mm (screwing furring batten to carrying batten) pcs mineral wool (consider fire protection specs, see pages 6 to 10) m m

Knauf Boards (see below) Screw attachment (fastening of Knauf Boards)


Knauf Drywall Screws TN 3.5 x 25 mm TN 3.5 x 35 mm TN 3.5 x 45 mm

1 17 0.4 0.3 0.4 0.45

2 9 17 0.4 0.5 0.6 0.45

1 27 0.4 0.3 0.4 0.45

2 9 27 0.4 0.5 0.6 0.45

pcs

Jointing
Trenn-Fix 65 Knauf Uniflott for hand filling; 25 kg bag resp. 5 kg bag Knauf Jointfiller Super for machine filling; 20 kg bag Joint Tape (for cut edges) m kg kg m

D111
1
0.15 *)

D113
Standard
Knauf Boards GKB / GKBI 12.5 mm hanger: 1000 mm; carr. batten: 900 mm; furr. batten: 500 mm 1
0.15 *)

Standard
12.5 mm Knauf Boards GKB / GKBI hanger: 1100 mm; carr. chan.: 1250 mm; lfurr. chan.: 500 mm

2
0.30 *)

Standard

F30 allein von unten

2
0.30 *)

Standard

F30 solely from below

Knauf Boards GKB / GKBI resp. GKF / GKFI 2x 12.5 mm hanger: 850 mm; carr. batten: 700 mm; furr. batten: 500 mm

Knauf Boards GKB / GKBI resp. GKF / GKFI 2x 12.5 mm hanger: 650 mm; carr. chan.: 1250 mm; furr. chan.: 500 mm

F30 solely from above


Knauf Boards GKF / GKFI 15 mm hanger: 650 mm; carr. chan.: 1250 mm; furr. chan.: 500 mm

*) load class kN/m as req. = as required

**) only necessary for fire protection


0.30 *)

27

D11 Knauf Board Ceilings


Consumption of Material of selected Examples
Consumption of material per m ceiling without allowance for loss and waste. Description
italic = not provided by Knauf Amounts refer to ceiling area of: 10 m x 10 m = 100 m

Unit

Amount as average value D112 3 1 2


0.4 0.4 0.4 0.4 0.4 0.4

4
0.4 0.4

D116 1
0.4 0.4

2
0.4 0.4

3
0.4 0.4

connection to wall
UD Runner 28x27x0.6; length 3 m fastener approved for substrate e.g. Knauf Ceiling Steel Dowel for reinforced concrete m pcs

substructure
alt. Knauf Ceiling Steel Dowel (for reinforced concrete) approved fastener Universal Bracket for CD 60x27 Metal Screws 2x LN 3.5x9 mm (fastening to CD Channel) pcs pcs 1.2 1.2 2.4 1.2 1.2 1.2 1.2 1.2 1.2 3.2 0.6 2.3 4.6 as req.

1.5 1.5 3.0 1.5 1.5 1.5 1.5 1.5 1.5 3.2 0.6 2.3 4.6 as req.

2.1 2.1 4.2 2.1 2.1 2.1 4.2 2.1 2.1 3.5 0.7 2.9 5.8 as req.

2.4 2.4 4.8 2.4 2.4 2.4 4.8 2.4 3.5 0.7 2.9 5.8 1.2 2 13 17 0.4 1 0.45

0.7 0.7 0.7 0.7 2.1 0.4 1.1 0.04 2.3


as req.

1 1 1 1 2.1 0.4 1.1 0.04 2.3


as req.

1.4 1.4 1.4 1.4 2.1 0.4 1.1 0.04 2.3 1.2 2 13 21 0.4 0.8 0.45

or

Hanging Wire Ankerfix Rapid Hanger for CD 60x27 alt. Combo Hanger for CD 60x27 or Nonius Hanger Top Nonius Pin Nonius Hanger Bottom for CD 60x27 Metal Screws 2x LN 3.5x9 mm (screwing with CD Channel) alt. Combo Hanger for CD 60x27 alt. Nonius Stirrup for CD 60x27 Nonius Stirrup for UA 50x40 CD Channel 60x27x0.6; length 4 m Multi-Connector (as longitudinal connection for CD Channels) UA Profile 50x40x2.0 UW Profile 50x40x0.6 (for extension of UA Profiles) alt. Intersection Connector for CD 60x27 2x Clip for CD 60x27 Intersection Connector for UA 50x40 mineral wool (consider fire protection specs, see pages 6 to 10) (see below) Knauf Boards Screw attachment (fastening of Knauf Boards) Knauf Drywall Screws TN 3.5 x 25 mm TN 3.5 x 35 mm TN 3.5 x 55 mm

pcs

pcs

pcs m pcs m m pcs pcs m m

1 17 0.4 0.3 0.4 0.45

2 9 17 0.4 0.5 0.6 0.45

2 13 21 0.4 0.8 0.45

1 17 0.4 0.3 0.4 0.45

2 9 17 0.4 0.5 0.6 0.45

pcs

Jointing
Trenn-Fix 65 Knauf Uniflott for hand filling; 25 kg bag resp. 5 kg bag Knauf Jointfiller Super for machine filling; 20 kg bag Joint Tape (for cut edges) m kg kg m

D112
1
0.15 *)

D116
Standard F30 below basic ceiling type II to III
1

Standard
Knauf Boards GKB / GKBI 12.5 mm

Knauf Boards GKB / GKBI resp. GKF / GKFI 12.5 mm hanger: 950 mm; carr. chan.: 1000 mm; furr. chan.: 500 mm

F30 below basic ceiling type II to III


0.15 *)

Standard
Knauf Boards GKB / GKBI 2x 12.5 mm

Knauf Boards GKF / GKFI 12.5 mm hanger: 2050 mm; carr. chan.: 1000 mm; furr. chan.: 500 mm

F30 solely from below / F60 below basic ceiling I to III


0.30 *)

Standard
Knauf Boards GKB / GKBI 2x 12.5 mm

2x 12.5 mm Knauf Boards GKF / GKFI hanger: 750 mm; carr. chan.: 1000 mm; furr. chan.: 500 mm

F30 solely from below / F60 below basic ceiling I to III


0.30 *)

3
0.50 *)

F90 solely from below


Knauf Boards GKF / GKFI (Solid Boards) 2x 20 mm hanger: 700 mm; carr. chan.: 800 mm; furr. chan.: 500 mm

Knauf Boards GKF / GKFI 2x 12.5 mm hanger: 1300 mm; carr. chan.: 1000 mm; furr. chan.: 500 mm

3
0.50 *)

F90 solely from below and from above


2x 20 mm Knauf Boards GKF / GKFI (Solid Boards) hanger: 800 mm; carr. chan.: 1000 mm; furr. chan.: 500 mm

F90 solely from below and from above


25 + 18 mm Knauf Boards GKF / GKFI (Solid Boards) hanger: 600 mm; carr. chan.: 750 mm; furr. chan.: 500 mm

28

0.50 *)

*) load class kN/m

as req. = as required

D11 Knauf Board Ceilings


Specifications

Item ......

Description Ceiling lining/ suspended ceiling * DIN 18168-1, installation height in m .........., suspension height in cm .............,* re resistance class according to DIN 4102-2 F30/ F60/ F90/ F120 *,* in connection with basic ceiling type I/ II/ III * DIN 4102-4, */ for ceiling lining solely resistant to re from below for protecting the basic ceiling, */ for suspended ceiling solely resistant to re from below for protecting the basic ceiling and the plenum, */ for suspended ceiling solely resistant to re from the plenum for protecting the room lying below, */ for suspended ceiling solely resistant to re from the plenum and from below for protecting the room lying below, the basic ceiling and the plenum *,* anchored on reinforced concrete/ wooden beams, spacing in cm ............./ steel girder, type .............., spacing in cm ............., * single/ double * layer cladding made of Knauf Boards GKB/ GKBI/ GKF/ GKFI * 12.5/ 15/ 18/ 20/ 25 * mm / LaVita Shielding Boards GKF 12.5 mm *, jointing in accordance with Code of Practice no. 2 (IGG, April 2003) quality standard Q1 basic lling to be coated with plaster/ ........... */ quality standard Q2 standard jointing *. Product/ System: Knauf Board Ceiling D111/ D112/ D113/ D116 *

No. of units

Unit price

Total price

.........

..........

..........

......

Ceiling lining/ suspended ceiling * DIN 18168-1, installation height in m .........., suspension height in cm .............,* re resistance class according to DIN 4102-2 F30/ F60/ F90 *,* for ceiling lining solely resistant to re from below for protecting the basic ceiling, */ for suspended ceiling solely resistant to re from below for protecting the basic ceiling and the plenum *,* anchored on reinforced concrete/ wooden beams, spacing in cm ............./ steel girder, type .............., spacing in cm ............., * installation of re protection ceiling with carrying channels and furring channels, suspended with Universal Bracket/ Nonius Suspension *, single/ double * layer cladding, made of Knauf Fire-Resistant Boards GKF, thickness 20/ 2x12.5/ 18+15/ 20+20/ 25+18 * mm installation of exposed ceiling with furring channels / carrying channels and furring channels *, suspended with Direct Brackets/ Universal Brackets * on furring channels of re protection ceiling, cladding made of Knauf Boards GKB 12.5 mm, jointing in accordance with Code of Practice no. 2 (IGG, April 2003) quality standard Q1 basic lling to be coated with plaster/ ........... */ quality standard Q2 standard jointing *. Product/ System: Knauf Ceiling D112 below re protection ceiling D112/ D116 * ......... m .......... ..........

......

Jointing as upgrade for gypsum board ceiling, for higher surface requirements, quality standard Q3 according to Code of Practice no. 2 (IGG, April 2003), tolerance atness with higher requirements according to DIN 18202, table 3, line 7,* on ceiling, application height in m .........., substrate gypsum boards, application of lling compound on the entire surface, scratched. Product: Knauf Readygips ......... m .......... ..........

......

Jointing as upgrade for gypsum board ceiling, for highest surface requirements, quality standard Q4 according to Code of Practice no. 2 (IGG, April 2003), tolerance atness with higher requirements according to DIN 18202, table 3, line 7, on ceiling, application height in m .........., substrate gypsum boards, to be coated with: smooth/ textured * ceiling linings with shine/ glaze/ paint coats/ coats with medium shine/ Stuccolustro/ other sophisticated smoothing technique *, application of special primer , pigmented white, organic based, Product: Knauf Putzgrund plaster primer and nishing plaster (skim coat) on the entire surface, thickness of coat: 2 mm, smooth surface. Product: Knauf Multi-Finish ......... m .......... ..........

* Cancel not applicable items

Sub-total ...............

29

D11 Knauf Board Ceilings


Specifications, Construction, Application

Item ......

Description Ceiling lining/ suspended ceiling * DIN 18168-1, installation height in m .........., suspension height in cm .............,* re resistance class according to DIN 4102-2 F30,* for ceiling lining solely resistant to re from below for protecting the basic ceiling, */ for suspended ceiling solely resistant to re from below for protecting the basic ceiling and the plenum, * anchored on reinforced concrete/ wooden beams, spacing in cm ............./ steel girder, type .............., spacing in cm ............., * cladding: single layer made of Knauf Boards GKF (4AK) 12.5 mm/ double layer made of one layer Knauf GKF 12.5 mm and one layer Knauf Boards GKF (4AK) 12.5 mm *, Jointing for higher surface requirements, quality standard Q3 according to Code of Practice no. 2 (IGG, April 2003), tolerance atness with higher requirements according to DIN 18202, table 3, line 7, application with Knauf Readygips/ TRIAS/ Jointller Super/ Fugenfller Leicht * and Joint Tape. Product/ System: Knauf Plattendecke D111/ D112/ D113/ D116 * 4AK

No. of units

Unit price

Total price

..........

..........

..........

......

Connection as angle prole/ joint/ UD Runner *, sliding/ fastened/ re resistance ............*, for ceiling lining/ suspended ceiling *, at entire perimeter, installation according to drawing no. ............... .

..........

..........

..........

* Cancel not applicable items

Sub-total ...............

Construction
Knauf Board Ceilings are anchored directly to the basic ceiling as a ceiling lining, or with a suspension as suspended ceiling. Knauf Boards are screwed on a wood frame made of carrying battens and furring battens (D111), on a metal grid made of carrying channels and furring channels (D112/ D116) or on a flush metal grid made of long and cross channels (D113. Select board type considering technical and building physical requirements. Settlement joints have to be taken over into the construction of the ceiling system. Use control joints in the case of ceiling areas over approx. 15 m length, or for narrow ceiling spaces caused by a break of a wall. Separate gypsum boards from building elements made with materials other than gypsum, especially columns, by creating control joints that allow for movement, e.g. shadow gap. By applying Knauf LaVita Shielding Boards a strong shielding of high frequency electromagnetic waves and of electrical alternating elds of low frequency can be achieved. Knauf proles are delivered galvanized. This corrosion protective coating is sufcient for indoor rooms, including bathrooms and kitchens in private housing. For other areas, e.g. exposed to outdoor air, additional corrosion protection is necessary (see DIN 18168-1 table 2).

Application
Substructure Anchoring to basic ceilings made of wood: Drywall Screws (used in accordance with Construction Supervisory Permit no. Nr. Z- 9.1251), reinforced concrete: Knauf Ceiling Steel Dowel (used in accordance with Construction Supervisory Permit no. Z-21.1-1519), other building materials: anchors have to be permitted and standardized for the building material being used. Fire protection from above: Use anchor that is approved for re protection purposes (Knauf Ceiling Steel Dowel). Suspension of channels only with suspenders according to page 10 (consider additional measures). Suspend with Hanging Wire and Ankerx Rapid Hanger (lock lever), Universal Connector, Combo Hanger or Rapid Wood Hanger, Universal Bracket, Nonius Hanger (screw with channel in case of re protection from above or total ceiling weight of 0.4 kN/m) or Nonius Stirrup. Secure Nonius Pin against sliding out. For spacings of anchors and channels or battens see tabels of systems. Connect carrying battens / channels with suspenders and align planely in required height. Connections of channels / battens D111: carrying battens to furring battens 50/30 with Knauf Drywall Screw TN 4.3 x 55 mm D112: carrying CD channel to furring CD Channel with CD Intersection Connector or Clips for CD 60x27 D113: long CD channel to cross CD Channel with Flush Connector or Universal Connectors D116: carrying UA Proles to furring CD Channels with UA Intersection Connector Connection to wall with UD Runner 28/27 as loadbearing connection, installation aid or in case of re protection; fastening with anchor that is suitable for the respective building material, spacing of fasteners 1 m max. (non load-bearing) resp. 625 mm max. (load-bearing). For sound protection requirements seal up carefully with acoustical sealant according to DIN 4109, supplement 1, chapter 5.2; porous sealant strips like Sealing Tape are usually not suitable in this case. Cladding Apply boards laterally to furring battens (D111)/ furring channels (D112/ D113/ D116). Apply cut edge joints on battens / channel and stagger them for at least 400 mm. If using 4AK Boards (4-side tapered egdes) cross joints are allowed in connection with lling with Joint Tape. Start fastening of Knauf boards either in the middle or at a corner in order to prevent upsetting deformation. Press boards rmly on to the grid and screw with Drywall Screws TN according to page 3. Carry out connections to other constructional components with Knauf Trenn-Fix 65 and ller, cover connection with runner/ board strips in case of re protection.

30

D11 Knauf Board Ceilings


Fastening of Loads, Jointing, Surface Treatment

Fastening of loads to Knauf Board Ceilings


Ceiling lights, curtain rods etc. can be fastened to board ceilings using universal dowels, cavity dowels or toggles. Single loads fastened directly to the cladding should not exceed 0.06 kN per span width of board. Additional loads (extra loads like ceiling lights, curtain rods etc.) have to be considered for the calculation of the total ceiling load according to diagram on page 2 or should be fastened directly to the basic ceiling. In case of re protection the fastening of loads to cladding or channels is not permissible, fastening of loads only to basic ceiling. Ceiling below Ceiling allows the installation of exposed ceilings 0.15 kN/m in case of re protection.

Jointing
For higher optical quality requirements like occuring streak of light, Knauf boards with 4AK edges are the ideal basis for perfect jointing with Joint Tape, Knauf Fugenfller Leicht or Readygips. With 4AK Boards the usual displacement of cut edges of at least 400 mm can be replaced by the much more effective cross joint application and jointing. Filling compounds without Joint Tape: hand lling with Knauf Uniott/ Uniott impregnated/ TRIAS with Joint Tape: hand lling with Knauf Fugenfller Leicht or machine lling with Ames machine and Knauf Jointller Super Knauf TRIAS matches the color of the paper of gypsum boards and has reduced suction properties after hardening surfaces lled with Knauf TRIAS are of low contrast and particular advantageous for paint coats and eece wallpapers Knauf Uniott impregnated is the system lling compound for impregnated Knauf Boards. It is water-repellent and matches the color of impregnated Knauf Boards use Knauf Finish-Pasts for the nal lling coat as ne skimming before sanding the joints Application for multi layer cladding, fill in joints of first layers, smooth joints of top layer ll all visible screw heads as well Recommendation: Fill cut edge joints of visible layers using tape no matter which filling material is used use Knauf Spezialgrund to prime the entire surface of lled Knauf Boards to control suction and for optical harmonization of the surface. Knauf Spezialgrund is a system component for the creation of surfaces with higher quality requirements quality standards Q1 to Q4 according to Code of Practice no. 2 Verspachtelung von Gipsplatten Oberchengten of the IGG Application time / climate Filling of joints should only take place after the boards have been allowed to rest in the given humidity and temperature zones, and no more longitudinal changes can be expected, i.e. expansion or contraction. Joints should be filled at a minimum temperature of +10C (50F). in case of mastic asphalt screed, fill in joints after screed has been applied

Surface treatment
Before applying paints or coats the lled surface should be dust-free. Use a primer on Knauf Boards before coating or painting them. Ensure that the primer and the coat or paint are compatible. To settle the different suction properties of the lled areas and the paper surface, primers like e.g. Knauf Tiefengrund/ Spezialgrund/ Putzgrund are suitable. In case of wallpaper lining a primer that allows an easier removal of wallpaper for redecoration is recommended. After wallpapering or plastering ensure adequate ventilation for fast drying. The following coats can be used on Knauf Cleaneo Acoustic Boards: wallpapers: paper-, textile and synthetic wallpapers. Use only adhesives made of cellulose according to Code of Practice no. 16 Technische Richtlinien fr Tapezier- und Klebearbeiten, Frankfurt/Main 2002, released by Bundesausschuss Farbe und Sachwertschutz. Plasters: Knauf structured plasters, Knauf indoor plasters, Knauf Acoustic Plaster, entire surface smoothing like e.g. Knauf Readygips or Knauf Multi-Finish, mineral plasters in connection with paper taped jointing. Coats: Resin dispersion paints, multicolored (rainbow) emulsion, oil paint, matte-nish lacquer, alkyd resin paint, polymer resin paint, PUR lacquer, or epoxybased lacquer, according to intended use or as required. Alkaline coats such as lime, water glass paints and silicate-based paints are unsuitable for gypsum board surfaces. Silicate-based emulsion paints may be used after referring to the manufacturers recommendations and following the stipulated guidelines closely. Gypsum plasterboard surfaces that have constantly been exposed to light without any protection can cause yellowing after coating. Therefore a trial coat is recommended that will extend across several boards including all joints. Yellowing can, however, be successfully avoided only by using a special primer.

31

D11 Knauf Board Ceilings


Declarations of Compliance

Declaration of compliance by the installer of the building component


Installer: (name, address) ................................................................................................................................................................................................. ................................................................................................................................................................................................. Site / building: Date of installation: Building Component / requirements: ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. It is certied herewith that the Knauf ceiling system as stated above has been built and installed in accordance with Knauf Technical Data Sheet D11 Knauf Board Ceilings, edition 2006-03 with the system components specified there, and has therefore been built regarding the declaration of compliance by the system manufacturer below in accordance with the valid building supervisory proofs concerning statics, sound insulation and fire protection.

.............................................................................................................. Place, date

.......................................................................................................... Stamp and signature

Declaration of compliance by the system manufacturer


Knauf Gips KG Am Bahnhof 7 97346 Iphofen, Germany It is certied herewith that the construction variants, application details and specied products included iniKnauf Technical Data Sheet D11 Knauf Board Ceilings, edition 2006-03 are fully in accordance with the specified valid building supervisory proofs respectively. As far as specified for the respective system / detail, this applies particularly to the calculation of statics according to DIN 18168 and / or DIN EN 13964 the fire protection according to ABP P-3400/4965-MPA BS and ABP P-3155/3992-MPA BS To fullfill the building supervisory requirements specified above in the installation of Knauf ceiling systems, building and application have to be done according to the valid edition of Knauf Technical Data Sheet D11with system components specified there. This has to be certified by the installer of the component with the declaration of compliance (see above) towards the contractor. Iphofen, March 2006

Prof. Dr. Hummel

Dr. Ruf

Phone: 09001 31-1000* Fax: 01805 31-4000 ** www.knauf.de knauf-direkt@knauf.de D11/engl./D/03.06/FB/D

The structural, statical properties, and characteristic building physics of Knauf systems can solely be ensured with the exclusive use of Knauf system components, or other products expressly recommended by Knauf.
Knauf Gips KG, Am Bahnhof 7, 97346 Iphofen, Phone: +49 9323 31-0, Facsimile: +49 9323 31-277
All technical changes reserved. Only the current printed instructions are valid. Our warranty is expressly limited to our products in flawless condition. All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areas. All rights reserved. All amendments, reprints and photocopies, including those of excerpts, require the express permission of Knauf Gips KG, Am Bahnhof 7, 97346 Iphofen, Germany. * A rate of 0.39 per minute will be charged if calling from the German landline network. Callers whose phone numbers are not registered within the address database of Knauf Gips KG (e.g. private builders or non-customers) will be charged a rate of 1.69 per minute. Calls from mobiles will be charged 1.48 per minute. ** 0.12 per minute

You might also like