Knauf Ceilings
Knauf Ceilings
Knauf Ceilings
2006-03
New
Design options for fire protection F30 to F90 solely from below and from above
y
65
60
50
45 0.30 < p 0.50 40 35
30
25 0.15 < p 0.30 20 0.15
*) design of ceilings 0.50 kN/m as well acc. to DIN 18168
15 11.5
10 45
x
9.5 12.5 15 18 20
(2x
25
5) 12.
30
15) (2x
33
(18 +15 )
40
(2x 20)
43
(25 +18 )
[ mm ]
thickness of cladding
2. Consideration of extra loads Extra loads from insulation required for fire protection and from insulation not required for fire protection (0.05 kN/m = 5 kg/m max.) as well as extra loads from system "Mulit-level Ceiling" (0.15 kN/m = 15 kg/m max.) increase the total weight per unit area of the suspended ceiling / ceiling lining and should be taken into account for the load class determination. The determined intersection point from the 1st step has to be parallel-shifted by the rate of the extra load in direction of the y-axis (upwards). 3. Determination of the load class The load class (kN/m) can be determined with the resulting total weight per unit area of the ceiling lining / suspended ceiling from steps 1 and 2. 4. Dimensioning the substructure Depending on fire protection requirements and load class the following spacings of the substructure are specified: without fire protection 1) fire protection from below 2)
spacings of suspenders / a anchors c spacings of carrying channels / timber battens normally dimensioned according to DIN 18168
fire protection from above (plenum) fire protection from below and from above
spacings of suspenders / anchors a have to be installed according to fire protection proofs
c spacings of carrying channels / timber battens b spacings of furring channels / timber battens
b 1) permissible span widths of spacings of furring channels / timber battens cladding acc. to DIN 18181 2) according to fire protection proofs normally use suspender 0.25 kN, for load class > 0.30 kN/m use suspender 0.40 kN.
suspenders and connectors according to fire protection proofs; Consider additionally required measures on pages 5 and 10.
Building physics
fire protection sound protection statics / strength
Sophisticated applications
surface quality mitering molded technology areas
Knauf Diamant (hard gypsum board) GKFI *) Knauf Fireboard A1 (special board for fire protection) KNAUF Piano (sound shield) KNAUF Piano F (sound shield) Knauf Fire-Resistant Board Knauf Solid Board Knauf Panel Board Knauf Wallboard
unsuitable suitable
GKB GKF / GKFI *) GKF / GKFI *) GKF / GKFI *) GKF / GKFI *) GKB / GKBI *)
more suitable most suitable
*) GKBI and GKFI (impregnated) boards are most suited for humid rooms
GKF
4-side tapered edges filling of front edges and long edges with Joint Tape cross-mounting
Allowable span widths of cladding according to DIN 18181 Board thickness Maximum spacings of furring channel / timber batten b without fire protection
12.5 / 2x 12.5 15 18 20 Solid Board / Panel Board 25 Solid Board 500 550 625 625 800
all dimensions in mm
In case of multi layer cladding, apply layers with staggered joints according to application scheme. Press boards of each layer firmly on to the substructure and screw each layer separately. For fastening of first layer, spacing of screws can be increased up to max. 500 mm (for cladding thickness 25 + 18 mm/ 2x 20 mm up to max. 300 mm according to installation scheme on page 22) if second layer is applied immediately afterwards (within one working day). In case of multi layer cladding, a filling of joints of first layer without further finishing is sufficient.
1250 1250
board width
alle dimensions in mm
without perimeter joint covering covering with UD Runner as installation aid / in case of fire protection and sound protection, spacing of anchors of UD Runner up to approx. 1 m ca. 100 *)
ca. 150
ca. 150
ca. 100 *)
ca. 150
ca. 100 *)
ca. 100 *)
Option 2
bearing connection
The spacing of anchors of the UD Runner is reduced to 625 mm (use a dowel suitable for substrate). Carrying / furring channels should be inserted into bearing UD Runners for 20 mm min. Maximum allowable spacings (suspenders, carrying / furring channel) are given in tables of respective system.
b
20
a
20
c
20
screw spacing 170 mm screwing of cladding into UD Runner is necessary 100 170 170
ca. 100 *)
ca. 100 *)
ca. 100 *)
Notes
All connections of board ceilings can be installed according either to option 1 or option 2. Connection details on the following pages show: option 1 D111, D112, D116 option 2 D113
UD 28x27
b
CD 60x27
a = spacing of suspenders (span width of carrying channels / timber battens) c = spacing of carrying channels / timber battens (span width of furring channels / timber battens) b = spacing of furring channels / timber battens (span width of cladding) *) max. cantilever of cladding height of construction = sum of suspension height, height of substructure and cladding thickness
Substructure
with wire
min. mm min. mm min. mm
Ceiling below Ceiling
Nonius Stirrup
mm mm
Direct Bracket timber batten / channel bxh 50x30 + 50x30 50x30 + 40x60 60x27 60x27 + 60x27 60x27 UA 50x40 + CD 60x27 total height mm
Combo Hanger
Combo Hanger
Universal Bracket
130 130
130 130 -
130 130 -
110 110 -
110 110 -
mm
1 -
60 90 27 54 27 67
Calculation example
D112 with Nonius Hanger Bottom (130 mm), carrying channels and furring channels (54 mm) and cladding (2x 12.5 mm) = 209 mm approx. 210 mm required height of construction for suspended ceiling
Combo Hanger
for CD 60x27
suspended with
Hanging Wire
Universal Bracket
anchoring to wood joist ceiling 2x Knauf TN 3.5x35 into tabs or 1x Knauf FN 5.1x35 in the middle acc. to ABZ Z-9.1-251 anchoring to concrete ceiling:
0 mm m/5 60 m
for CD 60x27 for UA 50x40 / for timber batten 50x30 mm screwed with TN 3.5x25 at sides
Nonius Stirrup
Bend Nonius Stirrup around channel and fit together until it snaps
suspended with
135 mm
125 mm
Nonius Pin
(secure against sliding out)
as required
Nonius Connector
Universal Connector
for CD 60x27
Combo Hanger
for CD 60x27
anchoring to concrete ceiling: in case of fire protection screw Universal Connector (used as suspender) to CD 60x27 (Metal Screws LB 3.5x9.5 mm)
Note
fire protection from above and from below fire protection from above (plenum) use fastener approved for fire protection Knauf ceiling steel dowel (mounted in accordance with ABZ Z-21.1-1519)
Type I Type II
Ceilings with steel girders exposed to plenum with U/A ratio of 300 m -1 and top cover made of light concrete in-situ concrete according to DIN 1045 or precast slabs with static effective coat of in-situ concrete according to DIN 1045 or precast units as core panels made of reinforced or prestressed concrete Ceilings made of reinforced or prestressed standard concrete slabs but without units or intermediate units made of light concrete or bricks Reinforced or prestressed concrete slabs acc. to DIN 1045 resp. DIN 4227 made of standard concrete Reinforced concrete ceilings with beams and intermediate units acc. to DIN 1045 made of standard concrete Two-way flat slab and coffered ceilings according to DIN 1045 made of standard concrete
Type III
Reinforced or prestressed core panels acc. to DIN 1045 resp. DIN 4227 made of standard concrete Reinforced concrete beam ceilings acc. to DIN 1045 without intermediate units or with intermediate units made of standard conrete
Fire protection from below and from above (basic ceiling) Board ceilings in connection with basic ceilings type I to III Knauf System Basic ceiling type acc. to DIN 4102-4 II III I Knauf System constr. cladding
min. thickness
a a a
(see page 7)
Fire resistance class K215 / K218 Knauf Fireboard Ceilings A1 with metal grid
mm
mm
mm
F90
S
not allowed not allowed not allowed
F90
400
S
not allowed not allowed
F90
Note
Spacings of suspenders and of carrying channels as well as installation and application according to Data Sheet K21 Knauf Fireboard Ceilings A1
Fire resistance class D112 / D116 Knauf Board Ceilings with metal grid F30
mm
mm
mm
F30
20 12.5 15 20 12.5 15 12.5 2x 15 25 (2x 12.5) 20 (2x 12.5) 25 (2x 12.5) 25 (2x 12.5) 20 (2x 12.5) 15 20 (2x 12.5) 20 15 12.5 15 15
500
G
not allowed not allowed
F30
G G
not allowed not allowed not allowed
F60
S 400
resp. not allowed not allowed not allowed
F60
500
(in case of double layer cladding)
S
not allowed not allowed not allowed
F60
S 500
not allowed
F90 Note
Spacings of suspenders (anchors) and spacings of furring channels according to tables of respective system all dimensions in mm
Proof
7 7 8
substructure
max. spacings
insulation
required for fire protection
thickness
from below
from above
2x 12.5 18 + 15
18 + 15 2x 20
500
mineral wool S 40 (60) + mineral wool S 40 (60) 150 mm wide 40 (30) 40 (30)
2x 12.5 18 + 15 2x 20
F60
F60
on carrying channels
F90
F90 25 + 18
500
mineral wool G 40 -
2x 12.5 18 + 15 25 + 18
F60 F90
Mineral wool insulation acc. to DIN EN 13162, chapter 3.1.1
Note Proof
Spacings of suspenders and of carrying channels acc. to table of respective system or in case of fire protection from above acc. to page 10 ABP P-3400/4965
substructure
max. spacings
insulation
required for fire protection
thickness
from below
from above
carrying channel
b
mm mm min. thickness mm min. denisty kg/m
D113 Knauf Board Ceiling with flush metal grid F30 15 18 F30 F30
Fire-Resistant Boards GKF, A2
500
F60 F90
F60 F90
F30
Universal Connector
F30
2x 12.5
500
D116 Knauf Board Ceiling with metal grid UA / CD 20 F30 2x 12.5 F60
Fire-Resistant Boards GKF, A2
18 + 15 2x 20
500
2x 12.5 18 + 15 2x 20
F60
F60
150 mm wide
F90 25 + 18
500
on carrying channel
fire protection ceiling solely from below D112, D116 + exposed ceiling (e.g. Cleaneo Acoustic Design Ceiling) 0.15 kN/m
Mineral wool
min. thickness mm
S
min. density kg/m
from above
(from the plenum)
scheme drawings
850
750
F30 to F60
750
600
F90
40 (60) 40 (60)
40 (30) 40 (30)
1250
650
Universal Connector
F30
1250
650
F30 to F60
40 (60) 40 (30)
1250
500
40 (60)
40 (30) 40 (30)
F90
40 (60)
F30 to F60
150 mm
F90
Additional constructional measures Flush Connector for CD 60x27: Nonius Hanger Bottom:
bend tabs and screw to lower channel (Metal Screws LN 3.5 x 9 mm) screw tabs to CD 60x27 (Metal Screws LN 3.5 x 9 mm) (Metal Screws LB 3.5 x 9.5 mm)
10
no fastening to UW Runner
no fastening to UW Runner
BSU
BSO
Note
In case of fire protection requirements for the partition the suspended ceiling should have at least the same fire resistance.
board strip
Fire-Resistant Board
BSA 1
BSA 2
BSA 3
board strips
Fire-Resistant Board
BSA 5
BSA 6
11
a
spacing of suspenders of exposed ceiling
F30 to F90
proof: see page 8
2 2
ch an ne ls
b
spacing of furring channels
sp ac
in g
of c
ar
ry in g
all dimensions in mm
Spacings of suspenders *) Spacings of furring channels load class kN/m b a 0.15 800 **) 400 / 500 400 / 500 500
(for Cleaneo Acoustic Ceilings see D12)
*) Fasten only to furring channels of fire protection ceiling. **) Fasten alternating to every second furring channel of the fire protection level if spacing of furring channels (fire protection level) is 400 mm.
Fasten to every furring channel of fire protection level if spacing of furring channels (fire protection level) is 500 / 625 mm.
Knauf Board
Universal Bracket for CD 60x27 Knauf All Purpose Screw FN 4.3x35 / FN 4.3x65 (acc. to ABP P-VHT-1802/05-FN)
Notes
12
install suspended channels of exposed ceiling always laterally to furring channels of fire protection ceiling max. load per suspension of exposed ceiling: 100 N
Cladding
Rated longitudinal sound reduction indices R L,w,R in dB without mineral wool full area layer of mineral wool 40 mm 80 mm
Examples of application
mm
46
47
48
53
54
54
48
52
54
55
57
57
Connection of partition to suspended ceiling, cladding separated with absorbent bulkhead *) 400 mm
60
Connection of partition to solid basic ceiling, with separation of suspended ceiling at cladding and construction
55
63
65
Connection of partition to solid basic ceiling (the cladding up to the solid ceiling is effective as separating bulkhead of the plenum)
65
*) absorbent bulkhead made of mineral wool acc. to DIN EN 13162, length related flow resistance value r 8 kPa s/m Note
In case of suspension height of more than 400 mm the values should be reduced by 1 dB.
13
ca. 250
a
spacing of suspenders
(anchors)
ca. 100
sp ac
in
of
ca rry c in g ba tte ns
(5
Max. spacings of substructure without fire protection fire protection from below
all dimensions in mm
Spacings of suspenders / anchors load class kN/m (see page 2) 0.30 0.15 1200 1150 1050 1050 1000 950 900 900 950 900 850 800 800 2)
a
0.50 800 750 700 2) 1)
1) use suspenders of load capacity class 0.40 kN 2) not valid for spacing of furring battens of 800 mm
14
Note
A customized dimensioning of the ceiling substructure is possible on request (e.g. for different batten dimensions).
0x 30
perimeter
option 1
see also page 4
mm
c 15 a. 0
longitudinal joint
longitudinal joint
alternate side of fastening
D111-D2
fasten Universal Bracket for wood batten with 2x Knauf Drywall Screws TN 3.5x25 to batten Knauf Ceiling Steel Dowel carrying batten
Knauf Drywall Screws TN 4.3x55 installation aid, required in case of fire protection as covering according to page 11 plaster or dry lining, fully filled with mortar at connection area in case of fire protection fastener suitable for substrate, spacing up to approx. 1 m
D111-B1
Longitudinal joint
D111-C1
Knauf Uniflott Drywall Screw TN 3.5x45 Panel Board 20 mm, width 625 mm
anchoring with fastener approved for building material carrying batten furring batten 50x30 (bxh)
15
ca. 250
a
spacing of suspenders
(anchors)
ca. 100
sp ac in g
of c ca rry in g
Maximum grid spacings without fire protection fire protection from below
alle dimensions in mm
Channel connections Carrying channel to furring channel Intersection Connector for CD 60x27
bend to 90 before installation
Spacings of suspenders
load class kN/m (see page 2) 1) 0.30 0.50 0.15 1200 1150 1100 1050 1000 950 900 900 950 900 850 800 800 750 750 2)
650 -
1) use suspenders of load capacity class 0.40 kN 2) not valid for spacing of furring channels of 800 mm
Notes
16
A customized dimensioning of the ceiling substructure is possible on request. It is recommended to dimension the substructure considering a possibly additional ceiling ( 0.15 kN/m).
ch an ne
perimeter
ls
option 1
see also page 4
c 15 a. 0
longitudinal joint
longitudinal joint
Combo Hanger - with wire 0.25 kN - with Nonius Hanger Top 0.40 kN
D112-D2
Connection to wall
furring channel CD 60x27 carrying channel CD 60x27 fasten Universal Bracket with Metal Screws LN 3.5x9 mm to carrying channel
Clip for CD 60x27 UD Runner 28x27 optional as installation aid, required for fire protection as covering according to page 11 fastener suitable for substrate, spacing up to approx. 1 m
D112-B2
Longitudinal joint
D112-C2
Knauf 4AK Board cross mounting (staggering of joints not necessary) filling with Joint Tape
17
D112-D3
Connection to wall
ca. 150 mm
c
Nonius Pin Nonius Hanger Bottom for CD 60x27 Intersection Connector for CD 60x27 carrying channel CD 60x27
ca. 250 mm
Nonius Hanger Top Nonius Pin Nonius Hanger Bottom for CD 60x27
filler + Trenn-Fix 65 furring channel CD 60x27 fastener suitable for substrate, spacing up to approx. 1 m plaster or dry lining, fully filled with mortar at connection area in case of fire protection
furring channel CD 60x27 Intersection Connector carrying channel CD 60x27 Knauf Board UD Runner 28x27 optional as installation aid, required for fire protection as covering according to page 11
D112-B4
Longitudinal joint
D112-C4
Knauf Ceiling Steel Dowel Hanging Wire Ankerfix Rapid Hanger Intersection Connector for CD 60x27
D112-B5
Longitudinal joint
D112-C1
Knauf Ceiling Steel Dowel Nonius Hanger Top Nonius Pin Nonius Stirrup for CD 60x27 Clip for CD 60x27 Intersection Connector for CD 60x27
Knauf Uniflott Drywall Screw TN 3.5x35 Panel Board 20 mm, width 625 mm
18
D112-D5
Nonius Pin Nonius Hanger Bottom for CD 60x27 Intersection Connector for CD 60x27 carrying channel CD 60x27
Clip for CD 60x27 Knauf Board Knauf Board strip filler + Trenn-Fix 65
Knauf Board furring channel CD 60x27 Joint Tape Drywall Screw TN mitered board
D112-B6
D113-B4
full area mineral wool layer thickness 40 mm UW Runner Knauf All Purpose Screw FN screwed into CD Channel
Knauf Uniflott + Trenn-Fix 65 cavity dowel or Knauf All Purpose Screw FN screwed with CD Channel UW Runner for connections of "lightweight" partitions to fire protective classified suspended ceilings see page 11.
D112-A3
D112-A4
c
Nonius Pin Nonius Hanger Bottom for CD 60x27 Intersection Connector for CD 60x27
Nonius Pin Combo Hanger for CD 60x27 with Nonius Hanger Top Intersection Connector
carrying channel CD 60x27 furring channel CD 60x27 Edge Trim (if necessary) e.g. U Perimeter Profile 28x27x48 fastener suitable for substrate, spacing up to approx. 1 m
Edge Trim furring channel CD 60x27 (if necessary) carrying channel CD 60x27 UD Runner 28x27 optional as installation aid
19
a
spacing of suspenders
(anchors)
a
spacing of suspenders
(anchors)
sp ac
in
of
lo
b
spacing of cross channels
Maximum grid spacings without fire protection fire protection from below Spacing of long channels Spacings of suspenders a load class kN/m (see page 2) 0.15 1100 1250 650 0.30 650 0.50
1)
all dimensions in mm
Channel connections Long channel to cross channel, flush Flush Connector for CD 60x27
b
500 400
for additional measures for fire protection from above see page 10.
optional folding point delivered unbent adjust roughly, depending on use adjust correctly during assembly
20
Note
ng
ch
perimeter
option 2
In case of D113 bearing UD Runner at entire perimeter, see also page 4
an ne
ls
<
12
20
Nonius Hanger Top with Nonius Hanger Bottom cross channel, length 1190 mm
Nonius Connector Nonius Pin Universal Connector as suspender with Nonius Hanger Top Nonius Hanger Top M6 / 16 mm
longitudinal joint
longitudinal joint
Universal Connector as suspender with Nonius Hanger Top 0.40 kN
D113-D2
Connection to wall
(load-bearing)
< 1220 mm
to center of long channel
a
spacing of suspenders
screwing of cladding with UD Runner required screw spacing 170 mm fastener suitable for substrate,
spacing 625 mm
plaster or dry lining fully filled with mortar at connection area in case of fire protection
UD Runner 28x27 long channel CD 60x27 screwing of cladding with UD Runner required screw spacing 170 mm fastener suitable for substrate,
spacing 625 mm
D113-B2
Longitudinal joint
D113-C2
Knauf Boards screw Universal Bracket with Metal Screws LN 3.5x9 to long channel
cross channel CD 60x27, length 1190 mm long channel CD 60x27 Knauf Ceiling Steel Dowel
Flush Connector for CD 60x27 long channel CD 60x27 cross channel CD 60x27, length 1190 mm
c
spacing of long channel
c
spacing of cross channels
21
dimensions in mm
1st layer
2nd layer 1st laer
Solid Board GKF 25 mm, width 625 mm
or
2x 20 mm Fastening screws
Knauf Drywall Screws Spacing of screws
2nd layer
Fire-Resistant Board GKF 18 mm, width 1250 mm
1st layer: TN 3.5x35 300 mm *) 2nd layer: TN 3.5x55 170 mm *) min. 3 screws per board width
ca.150
D113 F90
installation scheme
25 + 18 mm
Fastening screws
Knauf Drywall Screws Spacing of screws
Solid Board GKF 25 mm, width 625 mm (installed with long channel at center line)
2nd layer
Fire-Resistant Board GKF 18 mm, width 1250 mm 1250 1250 1250
1st layer: TN 3.5x35 300 mm *) 2nd layer: TN 3.5x55 170 mm *) min. 3 screws per board width
< 1220
D112F90vu-B1
Longitudinal joint
UD Runner 28x27 as covering for fire protection, see page 11 fastener suitable for substrate, spacing up to approx. 1 m
D113F90vu-D3
D113F90vu-B3
Longitudinal joint
a
spacing of suspenders fastener suitable for substrate, cross channel CD 60x27
spacing 625 mm
22
Solid Board GKF 25 mm Fire Resistant Board GKF 18 mm Drywall Screw TN 3.5x35
1st layer
2nd layer 1st layer
Cladding GKF
25 + 18 mm
Cladding GKF
ca. 100
D112-D4
Knauf Board strip GKF Edge Trim (if necessary) wood batten 30x50 (bxh) fastener suitable for substrate, spacing up to approx. 1 m
Knauf Board strip GKF Edge Trim (if necessary) UD Runner 28x27x0.6 fastener suitable for substrate, spacing up to approx. 1 m plaster or dry lining fully filled with mortar at connection area in case of fire protection
25 20 mm 20 mm Settlement joint
fire protection design
25 20 mm 20 mm
D111-C3
D112-C3
Settlement joint
fire protection design
glue Knauf Board strip GKF with Fugenfller Leicht at one side
> 25 >a a
> 25
a 20 mm
glue Knauf Board strip GKF with Fugenfller Leicht at one side Edge Trim 23x13 (if necessary)
a 20 mm
D113-C4
Settlement joint
fire protection design
glue Knauf Board strip GKF with Fugenfller Leicht at one side Edge Trim 23x13 (if necessary)
a 20 mm
23
ca. 250
a
spacing of suspender
(anchors)
ca. 100
sp ac
in
of
ca rry in g
Maximum grid spacings 1) without fire protection fire protection from below Spacing of carrying channels Spacings of suspenders a Nonius Stirrup (0.40 kN) load class kN/m (see page 2) 0.15 0.30 0.50 2600 2450 2300 2200 2150 2050 2000 1950 1900 1850 1750 2050 1950 1850 1650 1450 1300 1200 2)
alle dimensions in mm
c
500 600 700 800 900 1000 1100 1200 1300 1400 1500
850 -
1) spacing of suspenders max. 1700 mm 2) not valid for spacing of furring channels of 800 mm
A customized dimensioning of the ceiling substructure is possible on request. It is recommended to dimension the substructure considering a possibly additional ceiling ( 0.15 kN/m).
Notes
24
ch an ne l
perimeter
option 1
see also page 4
c 15 a. 0
D116-D1
Nonius Hanger Top Nonius Stirrup for UA 50x40 Nonius Pin Intersection Connector for UA 50x40 carrying channel UA 50x40
Nonius Hanger Top Nonius Stirrup for UA 50x40 Nonius Pin carrying channel UA 50x40
UD Runner 28x27 furring channel CD 60x27 filler + Trenn-Fix 65 Knauf Board fastener suitable for substrate spacing up to approx. 1 m
Drywall Screw TN UD Runner 28x27 optional as installation aid, required for fire protection as covering according to page 11 filler + Trenn-Fix 65
ca. 100 mm
D116-B1
Longitudinal jojnt
D116-C1
Knauf Ceiling Steel Dowel Nonius Hanger Top Nonius Stirrup for UA 50x40 Nonius Pin
Nonius Pin Nonius Stirrup for UA 50x40 Intersection Connector for UA 50x40
ca. 200 mm
25
Drywall Screw TN
Hhe -H-
Cladding of bulkhead
1.40 1.00
12.5 2x 12.5
Drywall Screw TN
Knauf Board
250 mm
250 mm
application according to Technical Data Sheet D19 Knauf Designed Ceilings
Knauf Board
Conduction and by-pass of partition and plenum LaVita Arrester Plate grounding via potential equalization LaVita Shielding Board 12.5 mm Knauf All Purpose Screw FN 4.3x35, screwing into metal stud LaVita Arrester Plate conductive side LaVita Shielding Board 12.5 mm covering of cut edge joint with conductive side LaVita Shielding Board
26
D12 Knauf Cleaneo Acoustic Ceilings / D15 Knauf Wood Joist Ceilings / D16 Knauf Ceiling Built-ins ( e.g. access panels, illuminations, ceiling bulkhead)
Unit
2
0.4 0.7
3
0.4 0.7
connection to wall
UD Runner 28x27x0.6; length 3 m fastener approved for substrate e.g. Knauf Ceiling Steel Dowel for reinforced concrete m pcs
substructure
alt. Knauf Ceiling Steel Dowel (for reinforced concrete) approved fastener pcs 1.3 1.3 2.6 1.3 1.3 2.6 1.2 2.1 2.5
as req.
0.7 0.7 1.4 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 1.4 0.7 1.4 0.8 0.2 1.9 1.5 3 as req.
1.2 1.2 2.4 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 2.4 1.2 2.4 2.4 0.8 0.2 1.9 1.5 3 as req.
1.2 1.2 2.4 1.2 1.2 1.2 2.4 0.8 0.2 1.9 1.5 6 1 1 27 0.4 0.35 0.45 0.45
Universal Bracket for CD 60x27 Metal Screws 2x LN 3.5x9 mm (fastening to CD Channel) alt. Universal Bracket for timber batten 50x30 Knauf Drywall Screws 2x TN 3.5x25 mm (screwing to batten) or Hanging Wire Ankerfix Rapid Hanger for CD 60x27 alt. Combo Hanger for CD 60x27 alt. Rapid Wood Hanger Knauf Drywall Screws 2x TN 3.5x35 mm (screwing to batten) or Nonius Hanger Top Nonius Pin Nonius Hanger Bottom for CD 60x27 Metal Screws 2x LN 3.5x9 mm (screwing to CD Channel) alt. Combo Hanger for CD 60x27 alt. Universal Connector (as suspender) M 6 / 16 2x Nonius Hanger Top Nonius Connector 2x Nonius Pin Metal Screws 2x LB 3.5x9.5 mm CD Channel 60x27x0.6; length 4 m Multi-Connector (as longitudinal connection for CD Channels) CD Channel 60x27x0.6; length 1.19 m Flush Connector for CD 60x27 Metal Screws 4x LN 3.5x9 mm (screwing to CD Channel) alt. Universal Connector
pcs
pcs
pcs
m pcs m pcs
m carrying batten 50x30 mm m furring batten 50x30 mm Knauf Drywall Screw TN 4.3x55 mm (screwing furring batten to carrying batten) pcs mineral wool (consider fire protection specs, see pages 6 to 10) m m
pcs
Jointing
Trenn-Fix 65 Knauf Uniflott for hand filling; 25 kg bag resp. 5 kg bag Knauf Jointfiller Super for machine filling; 20 kg bag Joint Tape (for cut edges) m kg kg m
D111
1
0.15 *)
D113
Standard
Knauf Boards GKB / GKBI 12.5 mm hanger: 1000 mm; carr. batten: 900 mm; furr. batten: 500 mm 1
0.15 *)
Standard
12.5 mm Knauf Boards GKB / GKBI hanger: 1100 mm; carr. chan.: 1250 mm; lfurr. chan.: 500 mm
2
0.30 *)
Standard
2
0.30 *)
Standard
Knauf Boards GKB / GKBI resp. GKF / GKFI 2x 12.5 mm hanger: 850 mm; carr. batten: 700 mm; furr. batten: 500 mm
Knauf Boards GKB / GKBI resp. GKF / GKFI 2x 12.5 mm hanger: 650 mm; carr. chan.: 1250 mm; furr. chan.: 500 mm
27
Unit
4
0.4 0.4
D116 1
0.4 0.4
2
0.4 0.4
3
0.4 0.4
connection to wall
UD Runner 28x27x0.6; length 3 m fastener approved for substrate e.g. Knauf Ceiling Steel Dowel for reinforced concrete m pcs
substructure
alt. Knauf Ceiling Steel Dowel (for reinforced concrete) approved fastener Universal Bracket for CD 60x27 Metal Screws 2x LN 3.5x9 mm (fastening to CD Channel) pcs pcs 1.2 1.2 2.4 1.2 1.2 1.2 1.2 1.2 1.2 3.2 0.6 2.3 4.6 as req.
1.5 1.5 3.0 1.5 1.5 1.5 1.5 1.5 1.5 3.2 0.6 2.3 4.6 as req.
2.1 2.1 4.2 2.1 2.1 2.1 4.2 2.1 2.1 3.5 0.7 2.9 5.8 as req.
2.4 2.4 4.8 2.4 2.4 2.4 4.8 2.4 3.5 0.7 2.9 5.8 1.2 2 13 17 0.4 1 0.45
1.4 1.4 1.4 1.4 2.1 0.4 1.1 0.04 2.3 1.2 2 13 21 0.4 0.8 0.45
or
Hanging Wire Ankerfix Rapid Hanger for CD 60x27 alt. Combo Hanger for CD 60x27 or Nonius Hanger Top Nonius Pin Nonius Hanger Bottom for CD 60x27 Metal Screws 2x LN 3.5x9 mm (screwing with CD Channel) alt. Combo Hanger for CD 60x27 alt. Nonius Stirrup for CD 60x27 Nonius Stirrup for UA 50x40 CD Channel 60x27x0.6; length 4 m Multi-Connector (as longitudinal connection for CD Channels) UA Profile 50x40x2.0 UW Profile 50x40x0.6 (for extension of UA Profiles) alt. Intersection Connector for CD 60x27 2x Clip for CD 60x27 Intersection Connector for UA 50x40 mineral wool (consider fire protection specs, see pages 6 to 10) (see below) Knauf Boards Screw attachment (fastening of Knauf Boards) Knauf Drywall Screws TN 3.5 x 25 mm TN 3.5 x 35 mm TN 3.5 x 55 mm
pcs
pcs
pcs
Jointing
Trenn-Fix 65 Knauf Uniflott for hand filling; 25 kg bag resp. 5 kg bag Knauf Jointfiller Super for machine filling; 20 kg bag Joint Tape (for cut edges) m kg kg m
D112
1
0.15 *)
D116
Standard F30 below basic ceiling type II to III
1
Standard
Knauf Boards GKB / GKBI 12.5 mm
Knauf Boards GKB / GKBI resp. GKF / GKFI 12.5 mm hanger: 950 mm; carr. chan.: 1000 mm; furr. chan.: 500 mm
Standard
Knauf Boards GKB / GKBI 2x 12.5 mm
Knauf Boards GKF / GKFI 12.5 mm hanger: 2050 mm; carr. chan.: 1000 mm; furr. chan.: 500 mm
Standard
Knauf Boards GKB / GKBI 2x 12.5 mm
2x 12.5 mm Knauf Boards GKF / GKFI hanger: 750 mm; carr. chan.: 1000 mm; furr. chan.: 500 mm
3
0.50 *)
Knauf Boards GKF / GKFI 2x 12.5 mm hanger: 1300 mm; carr. chan.: 1000 mm; furr. chan.: 500 mm
3
0.50 *)
28
0.50 *)
as req. = as required
Item ......
Description Ceiling lining/ suspended ceiling * DIN 18168-1, installation height in m .........., suspension height in cm .............,* re resistance class according to DIN 4102-2 F30/ F60/ F90/ F120 *,* in connection with basic ceiling type I/ II/ III * DIN 4102-4, */ for ceiling lining solely resistant to re from below for protecting the basic ceiling, */ for suspended ceiling solely resistant to re from below for protecting the basic ceiling and the plenum, */ for suspended ceiling solely resistant to re from the plenum for protecting the room lying below, */ for suspended ceiling solely resistant to re from the plenum and from below for protecting the room lying below, the basic ceiling and the plenum *,* anchored on reinforced concrete/ wooden beams, spacing in cm ............./ steel girder, type .............., spacing in cm ............., * single/ double * layer cladding made of Knauf Boards GKB/ GKBI/ GKF/ GKFI * 12.5/ 15/ 18/ 20/ 25 * mm / LaVita Shielding Boards GKF 12.5 mm *, jointing in accordance with Code of Practice no. 2 (IGG, April 2003) quality standard Q1 basic lling to be coated with plaster/ ........... */ quality standard Q2 standard jointing *. Product/ System: Knauf Board Ceiling D111/ D112/ D113/ D116 *
No. of units
Unit price
Total price
.........
..........
..........
......
Ceiling lining/ suspended ceiling * DIN 18168-1, installation height in m .........., suspension height in cm .............,* re resistance class according to DIN 4102-2 F30/ F60/ F90 *,* for ceiling lining solely resistant to re from below for protecting the basic ceiling, */ for suspended ceiling solely resistant to re from below for protecting the basic ceiling and the plenum *,* anchored on reinforced concrete/ wooden beams, spacing in cm ............./ steel girder, type .............., spacing in cm ............., * installation of re protection ceiling with carrying channels and furring channels, suspended with Universal Bracket/ Nonius Suspension *, single/ double * layer cladding, made of Knauf Fire-Resistant Boards GKF, thickness 20/ 2x12.5/ 18+15/ 20+20/ 25+18 * mm installation of exposed ceiling with furring channels / carrying channels and furring channels *, suspended with Direct Brackets/ Universal Brackets * on furring channels of re protection ceiling, cladding made of Knauf Boards GKB 12.5 mm, jointing in accordance with Code of Practice no. 2 (IGG, April 2003) quality standard Q1 basic lling to be coated with plaster/ ........... */ quality standard Q2 standard jointing *. Product/ System: Knauf Ceiling D112 below re protection ceiling D112/ D116 * ......... m .......... ..........
......
Jointing as upgrade for gypsum board ceiling, for higher surface requirements, quality standard Q3 according to Code of Practice no. 2 (IGG, April 2003), tolerance atness with higher requirements according to DIN 18202, table 3, line 7,* on ceiling, application height in m .........., substrate gypsum boards, application of lling compound on the entire surface, scratched. Product: Knauf Readygips ......... m .......... ..........
......
Jointing as upgrade for gypsum board ceiling, for highest surface requirements, quality standard Q4 according to Code of Practice no. 2 (IGG, April 2003), tolerance atness with higher requirements according to DIN 18202, table 3, line 7, on ceiling, application height in m .........., substrate gypsum boards, to be coated with: smooth/ textured * ceiling linings with shine/ glaze/ paint coats/ coats with medium shine/ Stuccolustro/ other sophisticated smoothing technique *, application of special primer , pigmented white, organic based, Product: Knauf Putzgrund plaster primer and nishing plaster (skim coat) on the entire surface, thickness of coat: 2 mm, smooth surface. Product: Knauf Multi-Finish ......... m .......... ..........
Sub-total ...............
29
Item ......
Description Ceiling lining/ suspended ceiling * DIN 18168-1, installation height in m .........., suspension height in cm .............,* re resistance class according to DIN 4102-2 F30,* for ceiling lining solely resistant to re from below for protecting the basic ceiling, */ for suspended ceiling solely resistant to re from below for protecting the basic ceiling and the plenum, * anchored on reinforced concrete/ wooden beams, spacing in cm ............./ steel girder, type .............., spacing in cm ............., * cladding: single layer made of Knauf Boards GKF (4AK) 12.5 mm/ double layer made of one layer Knauf GKF 12.5 mm and one layer Knauf Boards GKF (4AK) 12.5 mm *, Jointing for higher surface requirements, quality standard Q3 according to Code of Practice no. 2 (IGG, April 2003), tolerance atness with higher requirements according to DIN 18202, table 3, line 7, application with Knauf Readygips/ TRIAS/ Jointller Super/ Fugenfller Leicht * and Joint Tape. Product/ System: Knauf Plattendecke D111/ D112/ D113/ D116 * 4AK
No. of units
Unit price
Total price
..........
..........
..........
......
Connection as angle prole/ joint/ UD Runner *, sliding/ fastened/ re resistance ............*, for ceiling lining/ suspended ceiling *, at entire perimeter, installation according to drawing no. ............... .
..........
..........
..........
Sub-total ...............
Construction
Knauf Board Ceilings are anchored directly to the basic ceiling as a ceiling lining, or with a suspension as suspended ceiling. Knauf Boards are screwed on a wood frame made of carrying battens and furring battens (D111), on a metal grid made of carrying channels and furring channels (D112/ D116) or on a flush metal grid made of long and cross channels (D113. Select board type considering technical and building physical requirements. Settlement joints have to be taken over into the construction of the ceiling system. Use control joints in the case of ceiling areas over approx. 15 m length, or for narrow ceiling spaces caused by a break of a wall. Separate gypsum boards from building elements made with materials other than gypsum, especially columns, by creating control joints that allow for movement, e.g. shadow gap. By applying Knauf LaVita Shielding Boards a strong shielding of high frequency electromagnetic waves and of electrical alternating elds of low frequency can be achieved. Knauf proles are delivered galvanized. This corrosion protective coating is sufcient for indoor rooms, including bathrooms and kitchens in private housing. For other areas, e.g. exposed to outdoor air, additional corrosion protection is necessary (see DIN 18168-1 table 2).
Application
Substructure Anchoring to basic ceilings made of wood: Drywall Screws (used in accordance with Construction Supervisory Permit no. Nr. Z- 9.1251), reinforced concrete: Knauf Ceiling Steel Dowel (used in accordance with Construction Supervisory Permit no. Z-21.1-1519), other building materials: anchors have to be permitted and standardized for the building material being used. Fire protection from above: Use anchor that is approved for re protection purposes (Knauf Ceiling Steel Dowel). Suspension of channels only with suspenders according to page 10 (consider additional measures). Suspend with Hanging Wire and Ankerx Rapid Hanger (lock lever), Universal Connector, Combo Hanger or Rapid Wood Hanger, Universal Bracket, Nonius Hanger (screw with channel in case of re protection from above or total ceiling weight of 0.4 kN/m) or Nonius Stirrup. Secure Nonius Pin against sliding out. For spacings of anchors and channels or battens see tabels of systems. Connect carrying battens / channels with suspenders and align planely in required height. Connections of channels / battens D111: carrying battens to furring battens 50/30 with Knauf Drywall Screw TN 4.3 x 55 mm D112: carrying CD channel to furring CD Channel with CD Intersection Connector or Clips for CD 60x27 D113: long CD channel to cross CD Channel with Flush Connector or Universal Connectors D116: carrying UA Proles to furring CD Channels with UA Intersection Connector Connection to wall with UD Runner 28/27 as loadbearing connection, installation aid or in case of re protection; fastening with anchor that is suitable for the respective building material, spacing of fasteners 1 m max. (non load-bearing) resp. 625 mm max. (load-bearing). For sound protection requirements seal up carefully with acoustical sealant according to DIN 4109, supplement 1, chapter 5.2; porous sealant strips like Sealing Tape are usually not suitable in this case. Cladding Apply boards laterally to furring battens (D111)/ furring channels (D112/ D113/ D116). Apply cut edge joints on battens / channel and stagger them for at least 400 mm. If using 4AK Boards (4-side tapered egdes) cross joints are allowed in connection with lling with Joint Tape. Start fastening of Knauf boards either in the middle or at a corner in order to prevent upsetting deformation. Press boards rmly on to the grid and screw with Drywall Screws TN according to page 3. Carry out connections to other constructional components with Knauf Trenn-Fix 65 and ller, cover connection with runner/ board strips in case of re protection.
30
Jointing
For higher optical quality requirements like occuring streak of light, Knauf boards with 4AK edges are the ideal basis for perfect jointing with Joint Tape, Knauf Fugenfller Leicht or Readygips. With 4AK Boards the usual displacement of cut edges of at least 400 mm can be replaced by the much more effective cross joint application and jointing. Filling compounds without Joint Tape: hand lling with Knauf Uniott/ Uniott impregnated/ TRIAS with Joint Tape: hand lling with Knauf Fugenfller Leicht or machine lling with Ames machine and Knauf Jointller Super Knauf TRIAS matches the color of the paper of gypsum boards and has reduced suction properties after hardening surfaces lled with Knauf TRIAS are of low contrast and particular advantageous for paint coats and eece wallpapers Knauf Uniott impregnated is the system lling compound for impregnated Knauf Boards. It is water-repellent and matches the color of impregnated Knauf Boards use Knauf Finish-Pasts for the nal lling coat as ne skimming before sanding the joints Application for multi layer cladding, fill in joints of first layers, smooth joints of top layer ll all visible screw heads as well Recommendation: Fill cut edge joints of visible layers using tape no matter which filling material is used use Knauf Spezialgrund to prime the entire surface of lled Knauf Boards to control suction and for optical harmonization of the surface. Knauf Spezialgrund is a system component for the creation of surfaces with higher quality requirements quality standards Q1 to Q4 according to Code of Practice no. 2 Verspachtelung von Gipsplatten Oberchengten of the IGG Application time / climate Filling of joints should only take place after the boards have been allowed to rest in the given humidity and temperature zones, and no more longitudinal changes can be expected, i.e. expansion or contraction. Joints should be filled at a minimum temperature of +10C (50F). in case of mastic asphalt screed, fill in joints after screed has been applied
Surface treatment
Before applying paints or coats the lled surface should be dust-free. Use a primer on Knauf Boards before coating or painting them. Ensure that the primer and the coat or paint are compatible. To settle the different suction properties of the lled areas and the paper surface, primers like e.g. Knauf Tiefengrund/ Spezialgrund/ Putzgrund are suitable. In case of wallpaper lining a primer that allows an easier removal of wallpaper for redecoration is recommended. After wallpapering or plastering ensure adequate ventilation for fast drying. The following coats can be used on Knauf Cleaneo Acoustic Boards: wallpapers: paper-, textile and synthetic wallpapers. Use only adhesives made of cellulose according to Code of Practice no. 16 Technische Richtlinien fr Tapezier- und Klebearbeiten, Frankfurt/Main 2002, released by Bundesausschuss Farbe und Sachwertschutz. Plasters: Knauf structured plasters, Knauf indoor plasters, Knauf Acoustic Plaster, entire surface smoothing like e.g. Knauf Readygips or Knauf Multi-Finish, mineral plasters in connection with paper taped jointing. Coats: Resin dispersion paints, multicolored (rainbow) emulsion, oil paint, matte-nish lacquer, alkyd resin paint, polymer resin paint, PUR lacquer, or epoxybased lacquer, according to intended use or as required. Alkaline coats such as lime, water glass paints and silicate-based paints are unsuitable for gypsum board surfaces. Silicate-based emulsion paints may be used after referring to the manufacturers recommendations and following the stipulated guidelines closely. Gypsum plasterboard surfaces that have constantly been exposed to light without any protection can cause yellowing after coating. Therefore a trial coat is recommended that will extend across several boards including all joints. Yellowing can, however, be successfully avoided only by using a special primer.
31
Dr. Ruf
The structural, statical properties, and characteristic building physics of Knauf systems can solely be ensured with the exclusive use of Knauf system components, or other products expressly recommended by Knauf.
Knauf Gips KG, Am Bahnhof 7, 97346 Iphofen, Phone: +49 9323 31-0, Facsimile: +49 9323 31-277
All technical changes reserved. Only the current printed instructions are valid. Our warranty is expressly limited to our products in flawless condition. All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areas. All rights reserved. All amendments, reprints and photocopies, including those of excerpts, require the express permission of Knauf Gips KG, Am Bahnhof 7, 97346 Iphofen, Germany. * A rate of 0.39 per minute will be charged if calling from the German landline network. Callers whose phone numbers are not registered within the address database of Knauf Gips KG (e.g. private builders or non-customers) will be charged a rate of 1.69 per minute. Calls from mobiles will be charged 1.48 per minute. ** 0.12 per minute