Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Aqualung Conshelf 14 Users Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

Conshelf XIV

Conshelf XIV Supreme

User's Manual

Rev 09/09
2 CONSHELF XIV USER'S MANUAL

Copyright Notice
This owner’s manual is copyrighted, all rights reserved. It may not,
in whole or in part, be copied, photocopied, reproduced, translated,
or reduced to any electronic medium or machine readable form with
out prior consent in writing from Aqua Lung America, Inc.

©2009 Aqua Lung International


CONSHELF XIV User’s Manual P/N 108102

You can contact a Technical Advisor via e-mail at:

rbedard@aqualung.com
grubin@aqualung.com
dsumian@aqualung.com
dstancil@aqualung.com
Military sales: ksilver@aqualung.com

Trademark Notice
Aqua Lung® is a registered trademark of
Aqua Lung America, Inc.

Warnings, Cautions and Notes:

Pay special attention to information provided in


Warnings, Cautions and Notes that are accompanied
by one of these symbols:

A WARNING indicates a procedure or situation


that, if not avoided, could result in serious injury
or death to the user.

A CAUTION indicates any situation or technique


that could cause damage to the product, and
could subsequently result in injury to the user.

A NOTE is used to emphasize important points, tips,


and reminders.
CONSHELF XIV USER'S MANUAL 3

Contents
1. General Precautions & Warnings............................. 4
2. Introduction................................................................ 5
2.1 Product Description............................................... 5
3. Preparation and Setup...................................................6
3.1 Mount the 1st Stage to the Cylinder............................ 6
3.1.1 Yoke Connector .................................................6
3.1.2 DIN Connector.....................................................7
3.2 Pre-Dive Checks....................................................8
3.3 Pressurizing the Regulator.............................................8
3.4 Regulator Mouthpiece....................................................9
4. Diving with the Regulator............................................9
4.1 Using the Octopus........................................................9
4.2 Cold Water Diving.........................................................9
5. After The Dive...............................................................10
5.1 Removal of the Regulator from the Cylinder..............10
5.1.1 General Procedures...........................................10
5.1.2 Yoke Connector..................................................10
5.1.3 DIN Connector...................................................10
5.2 Cleaning.................................................................... 11
6. User Care and Maintenance................................... 11
7. Inspection and Service........................................... 12
7.1 Scheduled Service Exceptions. .............................. 13
8. Annual Inspection & Service Record.................... 14
First Stage Exploded View..................................... 15
Second Stage Exploded View................................ 16
Notes........................................................................ 17
4 CONSHELF XIV USER'S MANUAL

1. GENERAL PRECAUTIONS & WARNINGS


WARNING: Before using this regulator, you must have successfully
received training and certification in the technique of SCUBA diving
from a recognized training agency (or any Military or government
operated diving school). Use of SCUBA equipment by uncertified
or untrained persons is dangerous and can result in serious injury
or death.
WARNING: This regulator is not configured for commercial use
with surface supplied air.

WARNING: Always pressurize the regulator gradually by opening


the cylinder valve SLOWLY.

WARNING: NEVER lubricate any part of the regulator (particularly


the o-ring providing the seal between the cylinder valve and the
regulator) with any lubricants.

WARNING: DO NOT apply any type of aerosol spray on the


regulator. Doing so may cause permanent damage to certain
plastic or rubber components.

WARNING: Factory prescribed service for this regulator must


be performed at least once annually by a factory trained Aqua
Lung Service Technician. Repair, service, disassembly or first
stage adjustment must not be attempted by persons who are
not factory trained and authorized by Aqua Lung America Inc.

WARNING: DO NOT use the regulator first stage as a carry


handle when lifting or transporting the cylinder as this can
damage the regulator or the cylinder valve.

WARNING: When diving in cold water (below 50°F or 10°C), you


must have received training and certification in the techniques
of cold water diving from a recognized training agency.

WARNING: The Conshelf XIV is designated compatible for use


only with normal, atmospheric, compressed air (21% oxygen
and 79% nitrogen by volume). DO NOT attempt to use with other
gases, including pure oxygen or air which has been enriched with
oxygen exceeding 21% in content. Failure to observe this warning
may result in serious injury or death due to fire and explosion, the
serious deterioration and failure of the equipment.
CONSHELF XIV USER'S MANUAL 5

2. INTRODUCTION
Congratulations and thank you for choosing Aqua Lung. Your new
regulator meets all existing standards for quality and performance and
has been designed and manufactured with the greatest care.

Perhaps, more than any other item of equipment that you have bought,
the better care you take of your regulator, the better it will perform for
you. Its performance will be guaranteed through annual inspection/
servicing by an Authorized Aqua Lung Technician. Before diving with
your new Aqua Lung regulator it is important that you read this manual
in its entirety so that you can familiarize yourself with its features and
the rules for using the regulator before, during and after the dive so
as to retain optimum performance for the years to come.

2.1 PRODUCT DESCRIPTION


The Conshelf XIV consists of the basic Conshelf first stage and Conshelf
second stage assembly. It is available in the standard version or the Supreme
cold water (38°F+) version and both versions are U.S. Navy ANU listed.
First Stage
• The Conshelf XIV first stage is machined from Marine Brass and
chrome plated for durability.
• Capable of pressures up to 4350 psi with the DIN version.
• Adjustable Intermediate Pressure.
• Convertible to Supreme or Dry Environment versions.
• Available in Yoke
• DIN Conversion Kit available.
Second Stage
• The Conshelf XIV second stage is formed from Marine Brass and
chrome plated for durability.
• Multiple mouthpieces are available for a comfortable fit.
• Installed external lever height adjustment port for easy 2nd stage
adjustment.
Technical Specifications
Conshelf XIV Conshelf XIV Supreme
First Stage Technology Diaphragm Regulator Diaphragm Regulator
Maximum Working Pressure Yoke: 3300 PSI / 232 Bar Yoke: 3300 PSI / 232 Bar
DIN: 4350 PSI / 300 Bar DIN: 4350 PSI/ 300 Bar
Medium Pressure 140 ± 5 PSI 125 ± 5 PSI
Number / Size of Ports 1 HP 7/16", 4 MP 3/8" 1 HP 7/16", 4 MP 3/8"
Hose Length 30 " / 762 mm 30 " / 762 mm
6 CONSHELF XIV USER'S MANUAL

3. PREPARATION AND SET UP


Aqua Lung America, Inc. recommends that you bring your regulator to
an Authorized Aqua Lung Technician for the installation of any accessory
items, including instrumentation, LP quick disconnect hoses and alternate
air sources.

3.1 Mounting the First Stage onto the Cylinder Valve


3.1.1 Yoke Connector
1. Partially loosen the yoke screw of the first stage regulator so that the
dust cap can be removed from the filter and air inlet.
2. Remove the protector cap from the cylinder valve.
3. With the cylinder valve facing away from you, release a small amount
of air from the cylinder by turning the handwheel counter-clockwise to
open the valve only slightly. When air is heard exiting, immediately close
the valve. This will clear any moisture or debris that may be inside the
cylinder valve outlet opening.
4. Check the condition of the cylinder valve o-ring.
5. Place the first stage regulator over the cylinder valve so that the inlet
fitting aligns with the o-ring of the cylinder valve and the LP hose of the
primary second stage will be routed over the right shoulder. While holding
the first stage in place, turn the yoke screw clockwise. Ensure that the
yoke screw mates into the small dimple on the backside of the cylinder
valve and tighten finger tight only (Fig 1).

(Fig 1)
CONSHELF XIV USER'S MANUAL 7

3.1.2 DIN Connector


1. Remove the protector cap from the cylinder valve.
2. With the cylinder valve facing away from you, release a small amount
of air from the cylinder by turning the handwheel counter-clockwise
to open the valve only slightly. When air is heard exiting, immediately
close the valve. This will clear any moisture or debris that may be
inside the threaded cylinder valve opening.
3. Check the condition of the o-ring located in the end of the DIN connector.
4. Position the first stage regulator near the cylinder valve so the LP hose
of the primary second stage will be routed over the right shoulder.
Thread the first stage DIN connector into the cylinder valve, turning
the handwheel clockwise by hand until it is lightly snug. DO NOT use
tools to tighten (Fig 2).

NOTE: The Conshelf XIV does not come standard with a DIN
Connector. A DIN Adapter Kit , PN 107455, is available and
can be installed by a Trained Technician.

(Fig 2)
8 CONSHELF XIV USER'S MANUAL

3.2 Pre-Dive Checks


1. Carefully inspect all hoses at their fittings to ensure they are securely
connected onto their respective ports on the first stage. Inspect the length
of each hose to ensure that the hoses are not blistered, cut or otherwise
damaged. If hose protectors are present, slide the protectors back to
expose the hose fittings and inspect the hoses as described above.
2. Visually inspect both the first and second stage regulators (including the
octopus regulator if so equipped) for any signs of external damage.
3. Visually inspect the mouthpiece to ensure there are no tears or splits
and that it is securely fastened to the second stage body (including
the octopus regulator if so equipped).
4. Check that the needle of your submersible pressure gauge is on zero.
5. Fit your regulator to the cylinder, checking that the hoses are oriented
correctly.

3.3 Pressurizing the Regulator


WARNING: Before pressurizing the regulator, check the con-
dition of the hoses attached to the regulator.

1. If a submersible pressure gauge is attached to the regulator, ensure


that the gauge dial faces away from you.
2. SLOWLY open the cylinder valve counter-clockwise to pressurize
the regulator. When the valve is completely open, close it back one
quarter turn clockwise.
3. Check that there are no audible leaks from any hoses or the other
accessories attached to the regulator. NEVER DIVE with a regulator
that shows any signs of leakage when pressurized. If there is a leak
between the regulator and the cylinder valve, check that the regulator
is correctly attached and that the o-ring is in good condition.
CAUTION: Never attempt to reposition the hoses once the
regulator is under pressure. If they are not correctly oriented,
close the cylinder valve, purge the regulator and reposition
the hoses.
4. Check to ensure that the submersible pressure gauge is displaying an
accurate measurement of air pressure inside the cylinder at the time
of charging and is appropriate for your planned dive.
5. Depress the purge button momentarily to ensure that sufficient airflow
is provided to blow out any dust or debris which may have entered
the second stage.
6. Inhale slowly and deeply from the regulator several times. The
regulator must deliver enough air for you to breathe easily without
noticeable resistance.
CONSHELF XIV USER'S MANUAL 9

NOTE: When properly maintained, the Conshelf XIV Supreme


external diaphragm should be slightly indented when unpres-
surized. Upon pressurization, the external diaphragm will flex
slightly outward.
3.4 Regulator Mouthpiece
1. The Conshelf XIV comes standard with the Comfo Bite Mouthpiece in
black (PN 105885).
2. The Comfo Bite Mouthpiece is also available in Clear (PN 105884)
3. Standard mouthpieces in Black (PN 105879) & Clear (PN 105889) are
also available.
4. DIVING WITH THE REGULATOR
4.1 Using an Octopus Regulator
If an Octopus regulator is going to be used, it is recommended that you
obtain a Conshelf XIV Octopus Regulator (PN 108520) with a yellow hose
or (PN 108525) with a black hose. It is recommended that the mouthpiece
be covered to prevent the intrusion of foreign objects into the Conshelf XIV
second stage octopus.
While underwater the regulator may commence to free-flow. If this happens
turn the regulator so that the mouthpiece points downward.
4.2 Cold Water Diving
The use of a specialized regulator with an environmental dry chamber will re-
duce the possibility of regulator first stage failure. It is also vital to use a regulator
second stage intended for this type of diving. Also, the diver should be trained
and have mastered the techniques of cold water diving so as to be able to take
all precautions necessary to avoid freezing of the regulator.
In order to reduce the risks of the regulator freezing when diving in cold water (be-
low 50°F or 10°C), consider at least the following recommendations and respect
your dive training program procedure:
1. Protect your regulator from any accidental entrance of water into the
first or second stages.
2. Protect your equipment from the cold before the dive. More precisely,
keep your regulator and all it's accessories in a warm dry place.
3. Carry out all pre-dive checks of your equipment in a warm dry place,
before even going to the dive site.
4. Avoid breathing through the regulator or pressing the purge button in
very cold air before entering the water.
5. Avoid removing the regulator from your mouth during the dive, or when
on the surface. This will prevent cold water from entering the regulator
second stage.
6. As far as possible, avoid excessive effort during the dive.
7. Have your air source checked to ensure it meets Grade E standards
and is dry.
10 CONSHELF XIV USER'S MANUAL

5. AFTER THE DIVE


5.1 Removal of the Regulator from the Cylinder Valve
NOTE: If fresh water is available, rinse your regulator completely
before depressurizing it. This will help to prevent contaminants from
entering the sealing surfaces inside the regulator.

NOTE: It is very important to use care when removing the regulator


first stage from the cylinder valve to ensure that moisture does not
enter either the inlet opening of the regulator first stage or the opening
of the DIN valve.

5.1.1 General Procedures


1. Shut off the cylinder air supply by turning the cylinder valve handwheel
clockwise until it stops. DO NOT over tighten.
2. While observing the submersible pressure gauge (if equipped), depress
the purge button of the second stage. When the gauge reads zero and
airflow can no longer be heard from the second stage, release the
purge button.
5.1.2 Yoke Connector
1. Turn the yoke screw counter-clockwise to loosen and remove the first
stage from the cylinder valve.
2. Dry the dust cap with a towel or other lint free cloth. While you may
use air from your cylinder valve to blow the water off the dust cap, you
run the risk of blowing water into the filter.
3. Place the dust cap over the first stage inlet fitting and seal it securely in
place by tightening down the yoke screw.
4. With the cylinder valve facing away from you, open the valve slightly
to release a short burst of air, and then immediately close the valve.
This will clear any moisture that may have entered the valve opening.
Immediately place the protector cap over the opening of the valve to
prevent the entrance moisture or debris.
5.1.3 DIN Connector
1. Turn the DIN handwheel counter-clockwise to loosen and remove
the first stage from the cylinder valve.
2. Blow off any water inside the protective cap or wipe it out with a clean towel,
and wipe the threads of the regulator first stage connector clean and dry.
Install the cap over the threads of the regulator first stage connector.
3. With the cylinder valve facing away from you, open the valve slightly
to release a short burst of air, and then immediately close the valve.
This will clear any moisture that may have entered the valve opening.
Immediately seal the protector cap over the opening of the DIN valve
to prevent the entrance moisture or debris.
CONSHELF XIV USER'S MANUAL 11

5.2 Cleaning
Aqua Lung America recommends that the second stage regulator be
disinfected periodically using an FDA approved solution. The U.S.
Navy uses SaniZide Plus™- Delivered ready to use (no dilution) from
Safetec® or Advance TBE™- Delivered ready to use (no dilution) from
Infection Control Technology® or Confidence Plus™- dilute one ounce
per gallon of water from Mine Safety Appliances Company®

6. USER CARE AND MAINTENANCE


It is important to provide the proper preventative maintenance in order to
ensure the best possible performance and maximum life of your Aqua Lung
Regulator. The following maintenance procedures should be performed
routinely after each use to ensure that the regulator is cleaned, inspected
and prepared for the next use or for storage.

As soon as possible after diving, the regulator should be rinsed thoroughly


with fresh water while it is attached to a cylinder and pressurized with air.

Rinsing alone, however, will not sufficiently clean the regulator. To clean the
regulator as thoroughly as possible, Aqua Lung recommends:
1. Attach the regulator to a charged SCUBA cylinder, open the cylinder
valve to pressurize the regulator and thoroughly soak both the first and
second stages in a bath of fresh water.
2. After the regulator has been properly soaked, it is important to rinse it
vigorously by flushing the main spring cavity of the first stage regulator
(non-environmentally sealed models only), the second stage mouthpiece
and the openings in the second stage front cover with a strong stream
of water. This will remove the deposits of salt and minerals that were
loosened during soaking.

WARNING: If you use a garden hose, DO NOT use the high


pressure jet as this could damage the diaphragm and/or the
internal valve.

CAUTION: DO NOT depress the purge button or loosen the


first stage yoke if the regulator is submerged unpressurized.
Doing so will allow the entrance of moisture and will require
that the regulator be returned to an Authorized Aqua Lung
Technician for service.
3. Properly disconnect the regulator and wipe it as dry as possible. Hang
it by the first stage to ensure that all the remaining moisture drains from
the second stages and accessories.
4. DO NOT leave the regulator exposed to direct sunlight for prolonged
periods of time.
12 CONSHELF XIV USER'S MANUAL

5. When the regulator is completely dry, store it in a clean equipment box


or sealed inside a plastic bag. Do not store it where it may be exposed
to extreme heat or an electric motor, which produces Ozone. Prolonged
exposure to extreme heat, ozone, chlorine and ultraviolet rays can cause
premature degradation of the rubber parts and components.
6. Never store the regulator while it is still connected to the cylinder valve.

WARNING: Do not use any type of solvent or petroleum


based substance to clean or lubricate any part of the regu-
lator. Do not expose any part of the regulator to aerosol
spray, as some aerosol propellants attack or degrade the
rubber and/or plastic components.

7. INSPECTION & SERVICE


It cannot be assumed that a regulator is in good working order on the basis
that it has received little use since it was last serviced. Remember that
prolonged or improper storage can still result in internal corrosion and/or
deterioration of o-ring seals.

You must obtain factory prescribed service for your regulator at least once a
year from an Authorized Aqua Lung Technician, regardless of the amount of
use it has received. Your regulator may require this service more frequently,
depending on the amount of use it receives and the environmental conditions
in which it is used.

If the regulator is used for training purposes, it will require complete


overhaul and factory prescribed service every three to four months.
Chlorinated swimming pool water is an especially damaging environment
for SCUBA equipment, due to high levels of chlorine and pH balancing
chemicals that cause certain components to rapidly deteriorate.

Obtain service for your regulator at least once a year, from a


Authorized Aqua Lung Technician. Your personal safety and the
mechanical integrity of your regulator may depend on it.
CONSHELF XIV USER'S MANUAL 13

7.1 Scheduled Service Exceptions


If the regulator is subjected to less than 50 dives per year, it is permissible to
over haul it every other year with an inspection procedure being performed on
the “off” years. For example:

• Year #1 : Inspection

• Year #2 : Overhaul

• Year #3 : Inspection

• Year #4 : Overhaul, and so on.

• Both Inspections and Overhauls need to be documented in the Annual


Service & Inspection Record in the back of the Owner's Manual. If a
regulator is subjected to more than 50 dives per year, it should receive
the complete overhaul.

NOTE: A unit that receives heavy or frequent use, such as in


instructional or commercial applications, should be serviced at
least twice a year - or more often - depending on the conditions
of use and the manner in which it is maintained.
14 CONSHELF XIV USER'S MANUAL

8. ANNUAL INSPECTION & SERVICE RECORD


Date Dealer Name Technician Name Observations Stamp
CONSHELF XIV USER'S MANUAL 15

Conshelf 14 First Stage


DIN Kit
1
7 25a
3 8
9 25b
45
4 37
10 26

5 11
25 ft/lbs 25 ft/lbs
46 2 33.9 Nm 25 ft/lbs
33.9 Nm 33.9 Nm
18 ft/lbs 12
27 31
24.5 Nm 13 38
47 14
6
48 28
15 39

49
29
29
30 34 40
40 in/lbs
4.5 Nm 16
50
33 41
20 ft/lbs 36
27 Nm 42
32 35
43
22
51
19 44
23 21
20
17
15 in/lbs 24
1.7 Nm 18

Key #- Part # Description Key #- Part # Description


-------107700 First Stage, Conshelf XIV 26 -----101728 Spring Pad
-------108810 First Stage, Conshelf XIV Supreme 27-----105326 Spring Retainer (coarse thread)
-------108195 Overhaul Parts Kit, Military (1st & 2nd Stage) -----105926 Spring Retainer (fine thread)
-------108655 Overhaul Parts Kit, Supreme (1st Stage) 28-----105327 Spring
-------900001 Overhaul Parts Kit (* parts specific to this kit) 29-----845097 Washer, Main Spring (non-supreme only)
1------108185 Decal 30-----101549 Adjustment Screw (coarse thread)
2------107506 Yoke Screw ----- 106023 Adjustment Screw (fine thread)
3------101012 Dust Cap (assy)
4------820120 O-ring Used on Supreme Models
5------861068 Retaining Ring 28-----105944 Spring (coarse thread Supreme only)
6------700418 Yoke ----- 105327 Spring (fine thread & EFA Supreme)
7------863051 Retaining Ring 31-----108851 Spring Retainer (coarse thread)
8------845095 Washer, Filter, Nylon -----105927 Spring Retainer (fine thread)
------124628 Washer, Filter, Stainless 32-----108853 Secondary Diaphragm, Supreme
9------105106 Filter 33-----108852 Secondary Diaphragm, EFA Supreme
10-----104613 Spring 34-----108854 Adjustment Screw (EFA)
11-----105324 Spring Block 35-----108854 Diaphragm Retainer, Supreme
12-----828005 Back-up Ring, White, Split, Military Only 36-----108855 Silicone Fluid, 2 oz., Military Only
-----119129 *Back-up Ring, Black, Non-split
13-----820080 O-ring Used with "Dry" Environmental Kit
14-----101504 Spring -----100525 Dry Environmental Kit, Conshelf, Complete
15-----105321 HP Seat Black, Military (In Overhaul Parts Kit) 37-----124560 Spring Pad
n/s----M105320 HP Seat (seat black, Military spare) 38-----106317 Spring Retainer
n/s----105940 *HP Seat (blue) 39-----106356 Spring
16-----105333 Body, Conshelf XIV 40-----106026 Adjustment Screw
17-----105323 Pin 41-----106319 Piston
18-----101727 Pin Support 42-----106338 Decal
19-----820011 O-ring (3/8” Port) 43-----106337 External Diaphragm
20-----910912 Plug, MP Port, 3/8 inch 44-----106318 Diaphragm Retainer
-----104304 104304 Plug, MP Port, 3/8 inch DIN Kit
21-----957004 O-ring (7/16" HP Port) -----107455 DIN Adapter Kit, Conshelf
22-----101785 Adapter, HP, 7/16" Female to 3/8" Male 45-----107441 Protector Cap, DIN Connector
23-----910912 Plug, HP Port, 3/8 inch, Con XIV, pre-1998 46-----820094 O-ring
24-----103137 Plug, HP Port, 7/16 inch 47-----106056 Handwheel Retainer, Conshelf
25-----103425 *Diaphragm & Thrust Washer 48-----820039 O-ring
25a---103429 Diaphragm, Black, Military 49-----108652 Handwheel, Conshelf, 300 BAR
25b---- 821026 Thrust Washer, Military 50-----106057 DIN Adapter, Conshelf
51-----820014 O-ring
16 CONSHELF XIV USER'S MANUAL

Conshelf 14 Second Stage


40 in/lbs
4.5 Nm

25

23
15 in/lbs
40 in/lbs 26 1.7 Nm
4.5 Nm
24 18
17 22
21
20
19
*16

27
55 in/lbs 15
6.2 Nm 14
12 13
11 8a or b

10
7

9
6 4

8b

5
*NOTE:
When replacing a Conshelf XIV box bottom 3
manufactured before January ‘97 which does
not feature an external lever height adjustment
port, it is also necessary to order the port plug
and o-ring (items 17 & 18). These three items
2
are available in kit form, PN 108535.

NLA - No Longer Available

Key #- Part # Description Key #- Part # Description


------ 108530 Conshelf XIV Second Stage w/o hose 16---- 108122 Box Bottom
------ 108538 Conshelf XIV Supreme Second Stage w/o hose ---- 108535 Box Bottom Kit (includes 16, 17 & 18)
------ 108195 OverhaulPartsKit,Military(1st&2ndStage) 17---- 957025 O-ring
------ 108592 Overhaul Parts Kit, 2nd Stage 18---- 102004 Plug
1----- 108185 Decal, Conshelf XIV 19---- 107607 Washer (Cold Water)
2----- 103706 Purge Button w/ Adjustment Screw NLA-- 845022 Washer
3----- 102708 Purge Spring 20---- 107605 Lever (Cold Water)
4----- 107001 Box Top NLA-108513 Lever
5----- 390147 Box Top Clamp 21---- 107606 Spacer (Cold Water)
6----- 834023 Clamp Screw NLA-- 102517 Spacer
7----- 860037 Retaining Ring 22---- 102510 Locknut
8a---- 103732 Demand Diaphragm (U.S. Military Only) 23---- 104913 Clamp, Black
8b -- 100571 Demand Diaphragm, Liquid Injection Molded ---- 104940 Clamp, Clear
9----- 101919 Exhaust Tee 24---- 105885 Comfo Bite Mouthpiece, Black
10---- 105139 Exhaust Valve ---- 105884 Comfo Bite Mouthpiece, Clear
11----- 100444 Inlet Fitting ---- 105889 Standard Mouthpiece, Clear
12---- 820014 O-ring ---- 105879 Standard Mouthpiece, Black
13---- 108510 MP Seat 25---- 820010 O-ring
14---- 104903 Poppet 26---- 090015 MP Hose Assy, 3/8” x 30”
15---- 108504 Spring (Standard) 27---- 820011 O-ring
---- 108514 Spring (Octopus) N/S --- 108525 Octopus, w/39" Black Hose
N/S --- 108520 Octopus, w/39" Yellow Hose

Part numbers in BOLD ITALICS indicate standard overhaul replacement part.


CONSHELF XIV USER'S MANUAL 17

NOTES
Conshelf XIV
User's Manual

2340 Cousteau Court • Vista, CA 92081


Phone (760) 597-5000 • Fax (760) 597-4900
www.aqualung.com/military

©2009 Aqua Lung International PN 108102 Rev 09/09

You might also like