IES INDOOR REPORT

PHOTOMETRIC FILENAME : 19119D1.IES


DESCRIPTION INFORMATION (From Photometric File)
IESNA:LM-63-1995
[TEST] 19119
[DATE] 07/17/98
[LUMCAT] EHO400M-AR22-22CL P1(C)
[LUMINAIRE] DAY-BRITE 22" OPEN ACRYLIC HIGHBAY W/CONICAL LENS
[MORE] COATED LAMP LAMP POSITION 1
[LAMP] 400WMH
[BALLAST] ADVANCE 71A6091
[MANUFAC] PHILIPS DAY-BRITE
[OTHER] REFL. FACTOR: .00 TEST DISTANCE: 30 FT.
[MORE] SHIELDING ANGLE: -NOR 90 -PAR 90
CHARACTERISTICS
Lumens Per Lamp
Total Lamp Lumens
Luminaire Lumens
Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
Total Luminaire Watts
Ballast Factor
CIE Type
Spacing Criterion (0-180)
Spacing Criterion (90-270)
Spacing Criterion (Diagonal)
Basic Luminous Shape
Luminous Length (0-180)
Luminous Width (90-270)
Luminous Height

36000 (1 lamp)
36000
30812
86 %
67
458
1.00
Semi-Direct
1.48
1.50
1.44
Circular w/ Sides
0.00 ft
1.83 ft (Diameter)
1.27 ft

LUMINANCE DATA (cd/sq.m)


Angle In
Degrees

Average
0-Deg

Average
45-Deg

Average
90-Deg

45
55
65
75
85

16263
9703
6418
5392
5611

16275
9979
6568
5282
5312

16526
10177
6608
5367
5657

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.


Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

Page 1

IES INDOOR REPORT


PHOTOMETRIC FILENAME : 19119D1.IES
CANDELA TABULATION

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
155
160
165
170
175
180

0.0
7341
7420
7534
7635
7665
7623
7579
7263
6522
5314
4107
3088
2416
1926
1650
1471
1368
1331
1327
1361
1412
1469
1460
1402
1301
1206
1168
1187
1227
1128
901
666
514
480
517
547
0

22.5
7341
7436
7552
7634
7658
7642
7573
7277
6505
5342
4122
3173
2459
1962
1653
1465
1362
1325
1318
1349
1404
1462
1470
1419
1344
1270
1255
1313
1406
1433
1334
1057
676
503
515
543
0

45.0
7341
7432
7561
7643
7659
7655
7562
7248
6470
5318
4131
3176
2483
1971
1648
1441
1309
1260
1250
1282
1333
1385
1412
1371
1296
1231
1229
1306
1370
1439
1457
1219
747
516
515
541
0

67.5
7341
7390
7536
7617
7646
7659
7572
7284
6421
5354
4196
3226
2528
2008
1688
1486
1373
1335
1332
1365
1412
1458
1468
1410
1334
1252
1234
1300
1361
1348
1217
912
613
490
520
548
0

90.0
7341
7392
7538
7615
7635
7688
7613
7326
6488
5400
4228
3239
2471
1983
1662
1464
1366
1342
1358
1399
1440
1449
1409
1320
1212
1100
1044
1047
1037
943
789
593
501
487
516
545
0

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.


Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

Page 2

IES INDOOR REPORT


PHOTOMETRIC FILENAME : 19119D1.IES
ZONAL LUMEN SUMMARY
Zone

Lumens

%Lamp

%Fixt

0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180

6403.95
10885.23
17897.09
22914.24
4357.96
5472.63
7258.85
7898.07
30812.31

17.80
30.20
49.70
63.70
12.10
15.20
20.20
21.90
85.60

20.80
35.30
58.10
74.40
14.10
17.80
23.60
25.60
100.00

Total Luminaire Efficiency = 85.60%


ZONAL LUMEN SUMMARY
Zone

Lumens

0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

711.66
2159.76
3532.53
4481.28
4107.18
2904.68
2002.79
1571.04
1443.33
1470.77
1513.15
1374.05
1114.66
975.10
811.12
441.10
153.65
44.47

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.


Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

Page 3

IES INDOOR REPORT


PHOTOMETRIC FILENAME : 19119D1.IES
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
Effective Floor Cavity Reflectance 0.20
RC
RW

80
70 50 30 10

70
70 50 30 10

50
50 30 10

30
50 30 10

10
50 30 10

0
0

0
1
2
3
4
5
6
7
8
9
10

97
87
80
73
67
61
57
53
49
46
43

92
83
75
69
63
58
54
50
46
43
41

83
71
63
55
49
44
40
37
33
31
28

75
64
57
50
45
40
37
33
31
28
26

67
58
51
45
41
37
33
31
28
26
24

64
52
43
37
32
28
24
22
19
17
16

97
83
73
64
57
51
46
42
38
35
32

97
79
67
57
50
44
39
34
31
28
25

97
76
62
52
44
38
33
29
26
23
21

92
79
69
61
54
49
44
40
36
33
31

92
76
64
55
48
42
37
33
30
27
25

92
73
60
50
43
37
32
29
25
23
21

83
69
59
50
44
39
35
31
28
25
23

83
66
55
46
40
35
30
27
24
22
19

75
62
53
46
41
36
32
29
26
24
22

75
60
50
43
37
32
28
25
23
20
18

67
56
48
42
37
33
30
27
24
22
20

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.


Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

67
55
46
40
34
30
26
24
21
19
17

Page 4

IES INDOOR REPORT


PHOTOMETRIC FILENAME : 19119D1.IES
POLAR GRAPH

7688

5766

3844
2
1922

1
Maximum Candela = 7688 Located At Horizontal Angle = 90, Vertical Angle = 25
# 1 - Vertical Plane Through Horizontal Angles (90 - 270) (Through Max. Cd.)
# 2 - Horizontal Cone Through Vertical Angle (25) (Through Max. Cd.)

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.


Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

Page 5