Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

PVQ PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 68

Vickers

Piston Pumps

PVQ Piston Pumps


Variable Displacement, Quiet Series
For Industrial Applications

Revised 10/96

GB-C-2132

Introduction

PVQ piston pumps are in-line, variable


displacement units and are available in
nine sizes. Displacement is varied by
means of pressure and/or flow
compensator controls. An impressive
assortment of control options offers
maximum operating flexibility.
PVQs operate at quietness levels that
meet todays demanding industrial
conditions. The sound level of each unit
approaches or is below that of the
electric motor driving it. Sound is
reduced by a patented timing
arrangement that also produces low
pressure pulses in the outlet flow. This

Vickers, Incorporated 1997


All Rights Reserved

leads to reduced tendencies for noise in


systems using PVQs.
The PVQ series is capable of operating
with many types of hydraulic fluid.
Water-content and phosphate ester
fluids can be accommodated, in addition
to the typical petroleum based and
synthetic fluids.
Many PVQ pumps are available in a
thru-drive configuration to accommodate
a multitude of application and installation
requirements. Thru-drive models can be
coupled to various types and sizes of
fixed and variable displacement pumps,
resulting in a compact and versatile

package. Such a package offers lower


installed cost by reducing the installation
size and by requiring only one mounting
pad on the prime mover.
Quiet PVQs have excellent operating
characteristics, and the pumps many
control and mounting options allow
choosing the optimum model for any
application. Additionally, PVQs possess
the same durability and long life
characteristics expected of the best
industrial products in todays
marketplace. For over 75 years, the
Vickers name has been synonymous
with long trouble-free service.

Contents

Model Series

Maximum Geometric
Displacement
cm3/r (in3/r)

Rated Speed
r/min

Maximum Pressure
bar (psi)

Page

PVQ10

10,5 (0.643)

1800

210 (3000)

PVQ13

13,8 (0.843)

1800

140 (2000)

PVQ16

16,0 (0.976)

1800

210 (3000)

13

PVQ20

21,1 (1.290)

1800

210 (3000)

17

PVQ25

25,2 (1.540)

1800

210 (3000)

29

PVQ32

32,9 (2.010)

1800

140 (2000)

17

PVQ40

41,0 (2.500)

1800

210 (3000)

39

PVQ45

45,1 (2.750)

1800

186 (2700)

39

PVQ63

63,0 (3.844)

1800

210 (3000)

55

EDQ-L-30 Amplifier/Controller

61

Application Data

65

D Fluid Cleanliness
D Hydraulic Fluids and Temperature Ranges
D Fire Resistant Fluids
D Installation and Start-up
D Ordering Procedure

PVQ10 & PVQ13 Model Series

Ratings
Model
Series

Maximum Geometric
Displacement
cm3/r (in3/r)

Rated
Speed
r/min

Maximum
Pressure
bar (psi)

Input Power at Max.


Pressure & Rated Speed
kW (hp)

Approx.
Weight
kg (lb)

PVQ10

10,5 (0.643)

1800

210 (3000)

7,4 (10)

7,2 (16)

PVQ13

13,8 (0.843)

1800

140 (2000)

6,5 (8.75)

7,2 (16)

Pressure Limits
Case pressure 0,35 bar (5 psig) maximum
Inlet pressure 0,2 bar (5 in. Hg) vacuum to 2 bar (30 psig)

Model Code

1
1

P
V
Q
2

R
L
5

1
3
N

S
F

Pump design number

Inline piston pump


Variable volume
Quiet series

10 Design number subject to change.


Installation dimensions remain
unchanged for designs 1019.

Displacement in cc/rev and pressure


ratings

C**

Mounting flange specifications

CM**

Rotation viewed from shaft end


Right hand (cw), standard
Left hand (ccw), optional

C**V**B

Ports, type and location

Shafts, input
Straight keyed SAE A modified, .75
dia. x 1.75 long
Splined SAE A modified, 9T 16/32 DP
major dia. fit
Shaft end ISO 3019/2 E20N (available
with MA mount only)
Seals
Buna N, standard
Fluorocarbon, optional

10

11

C**VC**P

CG

Control type

SE SAE O-ring rear port, 1.0625 inlet


& outlet (standard)
SS SAE O-ring side port, 1.3125 linlet
& outlet (optional)
6

A2 Flange SAE J744 82-2 (SAE A)


MA Flange ISO 3019/2-80A2HW
(available with N drive shaft only)
4

Series PVQ

10 10,5 cc/rev (0.64 cir), 210 bar


(3000 psi)
13 13,8 cc/rev (0.84 cir), 140 bar
(2000 psi)
3

C**V**P

C**VC**B

Pressure compensator.
PVQ10: Standard model is
C21, indicating setting of 207
bar (3000 psi); range is 0221
in tens of bar (3503000 psi).
PVQ13: Standard model is
C14, indicating factory setting
of 138 bar (2000 psi); range is
0214 in tens of bar
(3502000 psi).
Low pressure compensator.
Standard model is CM7,
indicating factory setting of 69
bar (1000 psi); range is 0210
in tens of bar (3501500 psi).
Pressure compensator C**, as
above with load sensing.
Standard load sensing setting
is 11 bar (160 psi); range
1017 bar (150250 psi); with
bleed-down orifice. Example:
C21V11B indicates PVQ10
compensator with 207 bar
pressure setting and 11 bar
load-sense differential.
Pressure compensator with
load sensing as C**V**B
above, but with bleed-down
orifice plugged.
Pressure compensator with
load sensing. Compensator
same as C** above. Standard
load sensing setting is 24 bar
(350 psi), range 1731 bar
(250450 psi). With
bleed-down orifice.

CD**

UV

10

12

Pressure compensator with


load sensing. Same as
C**VC**B above, but with
bleed-down orifice plugged.
Pressure compensator
modified for hydraulic remote
control.
Electric dual range
compensator. PVQ10: CD21
is standard 210 bar setting of
high range (24210 bar).
PVQ13: CD14 is standard
140 bar setting of high range
(24140 bar). Both units
require low range to be set by
customer (20100 bar).
Unloading Valve for
accumulator circuits. See
installation details.

Control option

Blank Without adjustable maximum


displacement stop (standard)
D
Adjustable maximum displacement
stop (optional)
11

11
11
12
20
12

Control design

C** and CM**


C**D and CM**D
C**V(C)**B and C**V(C)**P
UV, CD** and CG

Special suffixes

S2 Shaft up mounting
S3 British Standard Parallel Threads
Counterbore Ports (ISO R288 threads).
Contact Vickers for available
configurations.
S9 Special CG compensator for use with
electronically modulated relief valves

Controls

adjusts pump flow in response to a


remote pressure signal and maintains
outlet pressure at a level slightly above
load pressure. The integral pressure
limiter overrides the load sensing
control, reducing pump displacement as
the preset maximum operating pressure
is reached.

Pressure Compensators
C & CM
The pressure compensator control
automatically adjusts pump delivery to
maintain volume requirements of the
system at a preselected operating
pressure. Maximum pump delivery is
maintained to approximately 3,4 bar (50
psi) below the pressure setting before
being reduced. The pressure
compensator control operates on one
side of center and has an adjustment
range as designated in the model coding.

Standard load-sense differential pressure


settings, by control type, follow. See
model code for setting range.

CG
requirements of the system at either of
two preselected operating pressures.
Maximum pump delivery is maintained
to approximately 3,4 bar (50 psi) below
either pressure control setting before
being reduced.
Control type and pressure range are
designated in the model code.

C**V11B Standard load-sensing and


pressure limiting control with 11 bar
differential pressure (standard factory
setting). Includes bleed-down orifice to
exhaust load-sense signal for
low-pressure standby condition.
C**V11P Same as C**V11B above,
but with bleed-down orifice plugged.
C**VC24B Same as C**V11B, but
with factory differential pressure setting
of 24 bar.
C**VC24P Same as C**V11P, but
with factory differential pressure setting
of 24 bar.

C & CM

Pressure Compensator with


Adjustable Maximum
Displacement Stop D
The adjustable maximum stop pressure
control enables the maximum pump
delivery to be externally adjusted from
25% to 100% while maintaining all of the
standard features of a pressure
compensated pump. To assist initial
priming, manual adjustment control
setting must be at least 40% of
maximum flow position.

Remote Control Pressure


Compensator CG
Exactly the same as the C (pressure
compensation option) except the
machine operator is able to change the
compensator setting through the use of
a remote pilot relief valve, such as
Vickers C-175.

CD

Note: Graphic symbols shown with


external valve(s) and cylinder to
illustrate typical usage.

Electric Dual Range Pressure


Compensator CD

Load Sensing & Pressure


Limiting Compensators

The dual range pressure compensator


control automatically adjusts pump
delivery to maintain volume

C**V***B ({orifice open)


& C**V***P ({orifice plugged)

This compensator provides load sensing


control under all pressure conditions up
to the desired maximum. It automatically
3

PVQ10 Model Series


Note: To obtain full flow operation of pump, pressure compensator
setting must be 14 bar (200 psi) above desired operating pressure.
Full flow curves were obtained with compensator settings 14 bar
(200 psi) above 210 bar (3000 psi) max. rated pressure.

Volumetric efficiency

Performance Data
Oil type:
SAE 10W
Oil temperature: 49C (120F)
Inlet:
0.2 bar (5 in. Hg)
100%

80%

210 bar (3000 psi)


140 bar (2000 psi)
70 bar (1000 psi)
35 bar (500 psi)

60%

40%

100%
Overall efficiency

70 bar (1000 psi)

140 bar (2000 psi)

80%

60%

35 bar (500 psi)


210 bar (3000 psi)

40%
l/min
32

USgpm
8

16

140 bar (2000 psi)


70 bar (1000 psi)
35 bar (500 psi)

210 bar (3000 psi)

Input power

kW
15

hp
20
15

10

Delivery

10

210 bar (3000 psi)


140 bar (2000 psi)
70 bar (1000 psi)
35 bar (500 psi)
500

1000
Speed r/min

1500

2000

Input power

Delivery

24

PVQ13 Model Series


Note: To obtain full flow operation of pump, pressure compensator
setting must be 14 bar (200 psi) above desired operating pressure.
Full flow curves were obtained with compensator settings 14 bar
(200 psi) above 210 bar (3000 psi) max. rated pressure.

Volumetric efficiency

Performance Data
Oil type:
SAE 10W
Oil temperature: 49C (120F)
Inlet:
0.2 bar (5 in. Hg)
100%

80%

140 bar (2000 psi)


70 bar (1000 psi)
35 bar (500 psi)

60%

40%

Overall efficiency

100%

80%

140 bar (2000 psi)


70 bar (1000 psi)
35 bar (500 psi)

60%

40%
USgpm

l/min
32

16

140 bar (2000 psi)


70 bar (1000 psi)
35 bar (500 psi)

Input power

kW
15

hp
20
15

10
10
5

Delivery

140 bar (2000 psi)


70 bar (1000 psi)
35 bar (500 psi)
500

1000
Speed r/min

1500

2000

Input power

Delivery

24

Sound Data
Sound Level dB(A)*
Full Stroke
Speed
r/min

Cutoff
PVQ13

51

53

43

42

55

54

48

50

100 (1500)

56

55

50

52

57

61

51

56

175 (2500)

59

51

35 (500)

53

54

46

44

70 (1000)

55

54

49

52

100 (1500)

56

58

51

56

140 (2000)

57

65

53

57

175 (2500)

60

54

35 (500)

56

56

47

44

70 (1000)

59

59

49

51

100 (1500)

59

60

51

55

140 (2000)

60

67

53

56

175 (2500)

62

53

35 (500)

58

58

52

49

70 (1000)

60

61

53

56

100 (1500)

62

63

55

58

140 (2000)

63

57

175 (2500)

1800

PVQ10

140 (2000)

1500

PVQ13

70 (1000)

1200

PVQ10

35 (500)

1000

Pre
re
Pressure
bar (psi)

65

57

*Sound pressure data equivalent to NFPA Standard.

Temperature: 50C (120F)


Test Fluid:
URSA-ED (10W)
Inlet Pressure: Atmospheric (0 psig)

Note: To ensure maximum noise


reduction at full flow conditions,
Engineering recommends limiting
pressure of PVQ10 to 175 bar (2500
psi) and PVQ13 to 100 bar (1500 psi) at
1800 rpm.

Response Data
Yoke response recorded at rated speed and pressure, 0 psi inlet, 82C (180F), SAE 10W oil. Pressure rise was 6900 bar
(100,000 psi) per second.
PVQ10

PVQ13

Control Type

On stroke

Off stroke

On stroke

Off stroke

Pressure compensator

0.040 sec.

0.020 sec.

0.048 sec.

0.016 sec.

Rear Ports, C & CM Controls, No.1 Shaft


Installation dimensions in mm (inches)
Compensator position
for R.H. rotation models
20,6
(0.81)R

162,8
(6.41)

Outlet connection for R.H.


rotation models 11/16-12
UN-2B straight thd. (0.75
O.D. tubing)

108,7
(4.28)

Compensator
position for
L.H. rotation
models

44,4
(1.75)

69,8
(2.75)
12,7
(0.50)

6,3(0.25)
6,1(0.24)

130
(5.12)D

Caution: While pump is operating do


not back compensator adjustment
screw out beyond dimension shown.

177
(6.97)

Case drain connection


.562-18 UN-2B straight
thd for .375 O.D.
tubing

28,4
(1.12)

84,8
(3.34)

84,8
(3.34)

Model number
shown here

79,2
(3.12)

50
(1.97)
82,55 (3.250)
82,50 (3.248) D
33,5 16,8
(1.32) (0.66)
Right hand
rotation

53,2
(2.09)
106,4
(4.188)

47,7
(1.88)R

11,1
(0.437)D
2 holes

4,79 (0.1885)
square
4,76 (0.1875)

52,3
(2.06)

28,6
(1.125)

163,6
(6.44)
25,4
(1.00)

Compensator
adjustment
screw 0.94 hex

19,05 (0.750)
D
19,02 (0.749)
Direction of rotation
shown here

38,1
(1.50)

21,13 (0.832)
21,00 (0.827)

28,4
(1.12)

57,1
(2.250)
67,8
(2.67)

Alternate
case drain
connection

135,9
(5.35)

Outlet connection for L.H. rotation


models 11/16-12 UN-2B straight
thd. (0.75 O.D. tubing)

Side Ports

Outlet connection 1.3125-12


UN-2B straight thd. (1.00 O.D.
tubing) for R.H. rotation models

153,2
(6.03)

79,2
(3.12)

50
(1.970)
Port
B

Port
A

38,1
(1.50)

177
(6.97)
Outlet connection 1.3125-12
UN-2B straight thd. (1.00 O.D.
tubing) for L.H. rotation models

165,1
(6.500)

52,3
(2.06)

82,5
(3.250)

No. 3 Shaft

N Shaft with MA Flange


(Flange and shaft end ISO 3019/2-80A2HW-E20N)

31,7
(1.25)
22,51
22,38
(0.886)
(0.881)

23,8
(0.938)

0.6249 Major
0.6245 Dia.

22,00
(0.866)
11,27
(0.444)

79,98
79,93
(3.149)
(3.147)

20,001
19,99
(0.788)
(0.787)

SAE standard involute spline flat root


major diameter fit. 9 teeth 16/32 pitch
diameter ref. .4835/.4725 minor diameter

36,0
(1.42)

5,99
5,97
(0.234)
(0.235)
Square key

8,51
(0.335)

7,24
(0.285)

54,50
(2.15)
109,00
(4.29)

Remote Compensator CG
Adjustment
1. Turn pressure control (such as C-175)
CCW to minimum setting.

Load Sensing with Pressure Limiting


Compensator C**V****
To mounting face
of pump mtg. flg.

2. Turn compensator adjustment plug to


desired minimum pressure (17 bar,
250 psi or higher).
3. Full pressure range can now be
obtained with pressure control.

Load sensing comp. control


port location for R.H.
rotation .4375-20 UNF-2B
boss connection

167,39
(6.59)
190,75
(7.51)

Caution:
Effective compensator pressure will be
CG compensator control setting (1769
bar, 2501000 psig) plus remote relief
valve setting.
Load sensing control port
location for L.H. rotation
45,1
(1.775)

28,45
(1.12)
Max.

19,05
(0.75)

28,45
D
(1.12)
.4375-20 UNF-2B
thread for CG
control models.
Connect to pressure
control, such as
C-175. SAE O-ring
boss connection
.250 O.D. tubing

Do not operate pump


with this port plugged.

Compensator adj. knob.


Do not back out adj. knob
beyond 28,4 (1.12) dim.
shown while pump is
operating.

Pressure Compensator
Control with
Adjustable Maximum
Displacement Stop D
Adjustment
Loosen locknut on adjusting rod. Turn
adjusting rod clockwise (CW) to
decrease maximum pump delivery, or
counter-clockwise (CCW) to increase
maximum pump delivery, until desired
setting is obtained. Secure this setting
by tightening locknut.

Adjustable maximum stop


pressure compensator control
position on left hand models

Minimum delivery position


(screw flush with nut)
Do not adjust below flush.

23,9 (0.94)
across flats
on hex.

232,9
(9.17)
194,6
(7.66)

94,5
(3.72)

15,7
(0.62)

50
(1.97)

22,7
(0.90)

94,5
(3.72)

28,4
(1.12)

87,9
(3.46)

Adjusting rod
(Approx. cc/rev
change per turn:
PVQ10 0.94
PVQ13 1.12)

Locknut 11,2 (0.44)


across flats

Vertical Shaft-up Installation S2 Drain Port Option

36,3
(1.43)
Additional drain port,
9/ -18 UNF-2B
16

Electric Dual Range


Pressure Compensator
Control CD
Adjustment
1. With the directional valve
de-energized, loosen locknut 5 and
turn the adjusting screw 4 to the
desired first stage pressure setting,
then tighten locknut 5.
2. With solenoid de-energized, turn
adjusting spool 1 counterclockwise
(CCW) until nut 3 is bottomed in
adjusting screw slot. (Second stage
setting is now equal to first stage
pressure setting.) Turn adjusting
spool clockwise (CW) to desired
second stage pressure
requirements. One complete turn of
adjusting spool equals
approximately 41 bar (600 psi).
Energize solenoid and check
pressure setting. De-energize
solenoid and re-adjust if necessary.
Secure this setting by tightening
locknut 2.

1. Adjusting spool sets


second stage pressure

288,5
(11.36)

2. Locknut 17,3 (0.68)


across flats
3. Locknut must be
contained within slot of
adjusting screw as shown
4. Adjusting screw 25,4
(1.00) across flats sets
first stage pressure

5. Locknut 31,7 (1.25)


across flats
158,7
(6.25)

158,7
(6.25)

50
(1.97)

Position for
R.H. models
Dual range pressure
compensator position

Solenoid Data (110V AC 50 Hz and 115/120V AC 60 Hz)


Solenoid current
115/120V AC 60 Hz
110V AC 50 Hz

Inrush amps
(R.M.S.)
2.0

Holding amps
.54
.64*

* Maximum peak inrush amps approximately 1.4 x R.M.S. value shown.

Refer to catalog GB-C-2015B for additional solenoid valve data.


Note: Any sliding spool valve, if held

shifted under pressure for long periods


of time, may stick and not spring return
due to fluid residue formation and,
therefore, should be cycled periodically
to prevent this from happening.

10

Electrical conduit
conn. 1/2 NPTF thd.

Electric Dual Range


Pressure Compensator with
Maximum Displacement
Stop CD**D
Maximum Flow Adjustment
With the system pressure below both
compensator settings, loosen maximum
stop adjusting screw locknut and adjust
screw to desired flow position (turning
screw clockwise decreases flow and
turning screw counterclockwise
increases flow). To lock screw in
position tighten locknut. To assist initial
priming, adjust control setting to at least
40% of maximum flow position.

Electrical conduit
connection 1/2
NPTF thd.
Minimum delivery
position (flush with nut).
Do not adjust below flush.

170,4
(6.71)

Position for
R.H. models

22,9
(0.90)
168,4
(6.63)

168,4
(6.63)

50
(1.97)

Locknut 11,2 (0.44) across flats

15,7
(0.62)

Maximum stop (adjusting screw)

Compensator Control

.250-20 UNC thd.

1. With the directional valve


de-energized, loosen locknut 5 and
turn the adjusting screw 4 to the
desired first stage pressure setting,
then tighten locknut 5.
2. With directional valve de-energized,
turn adjusting spool 1
counterclockwise until nut 3 is
bottomed in adjusting screw slot.
(Second stage setting is now equal
to first stage pressure setting.) Turn
adjusting spool clockwise to desired
second stage pressure
requirements. One complete turn of
adjusting spool equals
approximately 41 bar (600 psi).
Energize solenoid and check
pressure setting. De-energize
solenoid and re-adjust if necessary.
Secure this setting by tightening
locknut 2.

Maximum delivery position

1. Adjusting spool sets


second stage pressure

2. Locknut 17,3 (0.68)


across flats

212,8
(8.38)

91,4
(3.60)

3. Locknut must be
contained within slot of
adjusting screw as shown
4. Adjusting screw 25,4
(1.00) across flats sets
first stage pressure
5. Locknut 31,7 (1.25)
across flats

Solenoid Data (110V AC 50 Hz and 115/120V AC 60 Hz)


Solenoid current
115/120V AC 60 Hz
110V AC 50 Hz

Inrush amps
(R.M.S.)
2.0

Holding amps
.54
.64*

* Maximum peak inrush amps approximately 1.4 x R.M.S. value shown.

Refer to catalog GB-C-2015B for additional solenoid valve data.


Note: Any sliding spool valve, if held

shifted under pressure for long periods


of time, may stick and not spring return

due to fluid residue formation and,


therefore, should be cycled periodically
to prevent this from happening.

11

Unloading Valve Control UV


With the unloading valve control the
variable pump will unload at a preset
pressure. The pump will maintain this no
flow, low pressure (approximately 14 bar
[200 psi]) standby condition, until
system pressure drops to about 85% of
the preset unloading pressure. The
pump will then return on stroke and
provide full flow until the preset
unloading pressure is reached again.

Unload valve
control port
To load

Inlet

With this control, an efficient


accumulator charging circuit is obtained.
The pump will provide full flow to fill the
accumulator until the maximum
charging pressure is reached. The
pump then goes to a standby condition
until the accumulator pressure drops to
85% of the desired maximum. The
accumulator is then recharged as the
cycle starts over again.

Check Valve

Outlet
Drain

Setting Pressures
A separate right angle check valve must
be provided to maintain the accumulator
hydraulic charge and prevent back flow
when the pump is unloaded. The check
valves internal leakage must not
exceed five drops per minute. The
control port must be connected to
system pressure, downstream of the
check valve.

1. Back out accumulator unloading


pressure adjustment screw to below
desired unloading pressure.
2. Adjust desired standby pressure.

Adjustment range
PVQ10 100210 bar (15003000 psi)
PVQ13 100140 bar (15002000 psi)

3. Set accumulator pressure by


screwing in the accumulator
unloading adjustment screw.
Accumulator recharge (cut-in)
pressure is a function of the
maximum accumulator pressure
and is not adjustable.

Cut-in pressure is 85% of unloading


pressure, minimum.

4. Check pressure settings and


re-adjust if necessary.
Standby pressure
adjustment

198,4
(7.82)

Control Port .4375-20


UNF-2B thd. SAE O-ring boss
connection .25 OD tubing

Accumulator unloading
pressure adjustment

225,3
(8.87)

145,5
(5.95)

164,3
(6.57)

70,6
(2.78)

29,5
52,3 (1.16)
(2.06)

79,2
(3.12)

50,0
(1.97)
Port
A

Port
B

56,1
(2.21)

12

PVQ16 Model Series


Ratings

Model Series

Maximum
Geometric
Displacement
cm3/r (in3/r)

Rated
Speed
r/min

Maximum
Pressure
bar (psi)

Input Power at
Max. Pressure &
Rated Speed
kW (hp)

Approx.
Weight
kg (lb)

PVQ16

16,0 (0.976)

1800

210 (3000)

11,2 (15)

15 (33)

Pressure Limits
Case pressure 0,35 bar (5 psig) maximum
Inlet pressure 0,2 bar (5 in. Hg) vacuum to 2 bar (30 psig)

Model Code

P
V
Q
2

R
L
5

10

11

Seals

10

Inline piston pump


Variable volume
Quiet series

Buna N, standard

Pump design number

Blank Without adjustable maximum


displacement stop (standard)
D
Adjustable maximum displacement
stop (optional)

Displacement in cc/rev and pressure


ratings

Mounting flange specifications

Rotation viewed from shaft end


Right hand (cw), standard
Left hand (ccw), optional
Ports, type and location

SE Inch SAE O-ring boss rear port


6

A2 Flange SAE J744 82-2 (SAE A)


4

Series PVQ

16 16,0 cc/rev (0.976 cir), 210 bar


(3000 psi)
3

11 Design number subject to change.


Installation dimensions remain
unchanged for designs 1019.
9

Control type

11

Control option

Control design

10 CG and CV6
11 C**

C**

Pressure compensator. Standard


model is C21, indicating setting of
210 bar (3000 psi); range is 0221
in tens of bar (3503000 psi).
CG Pressure compensator modified for
hydraulic remote control.
CV6 Load sensing. Standard load sensing
setting is 6 bar (90 psi) differential.
No pressure compensation and no
bleed-down orifice. Relief valve is
required, such as Vickers CS-06.

Shafts, input
Shaft SAE J744 16-1 (SAE A)
Straight keyed

13

Pressure Compensator
Control C
The pressure compensator control
automatically adjusts pump delivery to
maintain volume requirements of the
system at a preselected operating
pressure.
Maximum pump delivery is maintained
to approximately 5 bar (70 psi) below
the control pressure before being
reduced.
The pressure compensator control
operates on one side of center and has
an adjustment range as designated in
the model coding.
P

Pressure Compensator Control


with Adjustable Maximum
Displacement Stop D
The adjustable maximum displacement
stop allows the maximum pump delivery
to be externally adjusted from 50% to
100%, while maintaining the standard
features of the pressure compensated
pump.

Remote Control Pressure


Compensator CG
This compensator is the same as the
C compensator, except the machine
operator is able to change the
compensator setting through the use of
a remote pilot relief valve. The pump
must not be operated with the remote
compensator port plugged; port must be
connected to a remote pilot relief valve,
such as Vickers C-175. The effective
compensator setting is the sum of the
compensator control setting and the
remote relief valve setting.

Load Sensing Compensator


Control CV6
This control provides load sensing
control under all pressure conditions up
to the system relief valve setting. It
automatically adjusts pump flow in
response to a remote pressure signal
and maintains outlet pressure at
approximately 6 bar (90 psi) above load
pressure. By venting the load-sense line
with external valving (e.g., Vickers
DG4V-3 directional valve), when no flow
or pressure demands are placed on the
system, the pump will go to a no-flow,
low pressure, energy conserving
standby mode.
This control does not include maximum
pressure limitation, so a separate
system relief valve (e.g., Vickers CS-03)
is required. The system relief valve will
limit the maximum system pressure to
the selected level.

P
LS

Dr

Max. displacement adjustment


D (optional)

C
Note:
Graphic symbols shown with external
valve to illustrate typical usage.

Dr

CG

14

CV6

Dr

Performance at 1800 r/min


100%

Overall efficiency
12 (16.1)

60%

Delivery l/min (USgpm)

40%

Input power

10 (13.4)
8 (10.7)

Delivery
6 (8.0)

30 (8.0)

4 (5.3)

20 (5.3)

Input power Kw (hp)

Efficiency

Volumetric efficiency
80%

Input power pump compensated


2 (2.6)

10 (2.6)
0

70
(1000)

140
(2000)

210
(3000)

Outlet pressure bar (psi)

Sound Data
Speed
r/min

Sound Level dB(A)*

Pressure
Press re
bar (psi)

Full Stroke

Cutoff

35 (500)

52

37

70 (1000)

59

56

55

40

56

48

140 (2000)

57

54

210 (3000)

58

55

35 (500)

57

46

70 (1000)

58

51

140 (2000)

59

55

210 (3000)

60

58

35 (500)

62

48

70 (1000)

63

53

140 (2000)

63

59

210 (3000)

1800

55

70 (1000)

1500

47

57

35 (500)
1200

54

140 (2000)
210 (3000)

1000

65

62

*Sound pressure data equivalent to NFPA Standard.

Temperature: 50C (120F)


Test Fluid:
URSA-ED (10W)
Inlet Pressure: Atmospheric (0 psig)

15

Response Data
Yoke response recorded at rated speed and pressure, 0 psi inlet, 82C (180F), SAE 10W oil. Pressure rise was 6900 bar
(100,000 psi) per second.
Control Type

On stroke

Off stroke

Pressure compensator

0.062 sec.

0.030 sec.

Load sense compensator

0.057 sec.

0.028 sec.

C Control with Control Option D


Installation dimensions in mm (inches)

Adj. screw
UNF

3/ -16
4

Case drain port Dr


3/ -16 UNF
4

Filling port

60
(2.36)

34
(1.34)

Square
4,785
4,760
(0.188)
(0.187)

87
(3.42)

For L models
Max. flow adj. rod
5 (0.20) hex hole

6,5
(0.25)

25,4
(1.00)

For R models

43
(1.69)

17,5 (0.69)
Max.

56
(2.20)

110,5
96
(4.35)
(3.78)

87
(3.42)
11,5
(0.45)
Effective
stroke

10,5
(0.41)
130

(5.12)

106
105
(4.17)
(4.13)

44,5
(1.75)

180
(7.08)

90
(3.54)

19,050
19,025
95

(0.750)
(3.74)
(0.749)
21,13 10,5
82,55
21,01 (0.41)
82,50 (0.830)

(3.250) (0.829)
(3.248)

CG and CV6 Controls


Non-adjustable

78
(3.07)
28,5
28,5
(1.12) Outlet port P
Inlet port I (1.12)
11/16-12 UN
11/16-12 UN
Shaft rotation and port

22,5
(0.88)
181
(7.12)

Rotation
R.H.
L.H.

Port I
Inlet
Outlet

Port P
Outlet
Inlet

117
(4.61)

Remote control port R for


CG control. Load sensing
port LS for CV6 control
7/ -20 UNF
16

96
(3.78)
56
(2.20)

78
(3.07)

Outlet port P
11/16-12 UN
28,5
(1.12)

43
(1.69)

28,5
(1.12)
Case drain port Dr
3/ -16 UNF
4

16

60
(2.36)

Filling port

Inlet port I
11/16-12 UN

PVQ20 & PVQ32 Model Series

Ratings
Model
Series

Maximum Geometric
Displacement
cm3/r (in3/r)

Rated
Speed
r/min

Maximum
Pressure
bar (psi)

Input Power at Max.


Pressure & Rated Speed
kW (hp)

Approx.
Weight
kg (lb)

PVQ20

21,1 (1.290)

1800

210 (3000)

14,9 (20)

14 (31)

PVQ32

32,9 (2.010)

1800

140 (2000)

15,6 (21)

14 (31)

Pressure Limits
Case pressure 0,35 bar (5 psig) maximum
Inlet pressure 0,2 bar (5 in. Hg) vacuum to 2 bar (30 psig)

Model Code

1
1

P
V
Q
2

Buna N, standard
Fluorocarbon, optional

10

11

Pump design number

Displacement in cc/rev and pressure


ratings

10 Design number subject to change.


Installation dimensions remain
unchanged for designs 1019.
10

Mounting flange specifications

Rotation viewed from shaft end


Right hand (cw), standard
Left hand (ccw), optional
Thru-drive without coupling
(available with side ports only)

C**V**B

Ports, type and location

Shafts, input

Straight keyed SAE B modified,


2.31 long
3 Splined SAE B modified, 13T
16/32 DP major dia. fit
N Shaft end ISO 3019/2 E25N (available
with MB mount only)
28 26-tooth splined shaft (Vickers). Used
in PVQ20/32 single to mount on
PVQ40/45 B26 thru-drive.

C**V**P

C**VC**B

Pressure compensator.
PVQ20: Standard model is
C21, indicating setting of 207
bar (3000 psi); range is 0221
in tens of bar (3503000 psi).
PVQ32: Standard model is
C14, indicating factory setting
of 138 bar (2000 psi); range is
0214 in tens of bar
(3502000 psi).
Low pressure compensator.
Standard model is CM7,
indicating factory setting of 70
bar (1000 psi); range is 0210
in tens of bar (3502000 psi).
Pressure compensator C**, as
above with load sensing.
Standard load sensing setting
is 11 bar (160 psi); range
1017 bar (150250 psi); with
bleed-down orifice. Example:
C21V11B indicates PVQ20
compensator with 210 bar
pressure setting and 11 bar
load-sense differential.
Pressure compensator with
load sensing as C**V**B
above, but with bleed-down
orifice plugged.
Pressure compensator with
load sensing. Compensator
same as C** above. Standard
load sensing setting is 24 bar

12

13

(350 psi), range 1731 bar


(250450 psi). With
bleed-down orifice.
Pressure compensator with
load sensing. Same as
C**VC**B above, but with
bleed-down orifice plugged.
Pressure compensator
modified for hydraulic remote
control.
Electric dual range
compensator. PVQ20: CD21
is standard 207 bar setting of
high range (24210 bar).
PVQ32: CD14 is standard
140 bar setting of high range
(24140 bar). Both units
require low range to be set by
customer (20100 bar).
Unloading Valve for
accumulator circuits. See
installation details.

C**VC**P

CG

CD**

UV

11

Control option

Control type

C**

SE SAE O-ring rear port, 1.625 inlet


& outlet (standard)
SS SAE O-ring side port, 1.625 linlet
& outlet (optional)
7

Seals

S
F

Blank No thru-drive
A9
SAE J744 82-2 (SAE A) w/9T spline
A11 SAE J744 82-2 (SAE A) w/11T spline
6

Inline piston pump


Variable volume
Quiet series

CM**
5

B2 Flange SAE J744 101-2 (SAE B)


MB Flange ISO 3019/2-100A2HW
(available with N drive shaft only)

R
L

Series PVQ

20 21,1 cc/rev (1.29 cir), 210 bar


(3000 psi)
32 32,9 cc/rev (2.01 cir), 140 bar
(2000 psi)
3

Blank Without adjustable maximum


displacement stop (standard)
D
Adjustable maximum displacement
stop (optional)
12

11
11
12
20
13

Control design

C** and CM**


C**D and CM**D
C**V(C)**B and C**V(C)**P
UV, CD** and CG

Special suffixes

S2 Shaft up mounting
S3 British Standard Parallel Threads
Counterbore Ports (ISO R288 threads).
Contact Vickers for available
configurations.
S9 Special CG compensator for use with
electronically modulated relief valves

17

to the desired maximum. It automatically


adjusts pump flow in response to a
remote pressure signal and maintains
outlet pressure at a level slightly above
load pressure. The integral pressure
limiter overrides the load sensing
control, reducing pump displacement as
the preset maximum operating pressure
is reached.

Pressure Compensator Controls


C & CM
The pressure compensator control
automatically adjusts pump delivery to
maintain volume requirements of the
system at a preselected operating
pressure. Maximum pump delivery is
maintained to approximately 75 psi
(PVQ20) or 100 psi (PVQ32) below the
pressure setting before being reduced.
The pressure compensator control
operates on one side of center and has
an adjustment range as designated in
the model coding.

Standard load-sense differential pressure


settings, by control type, follow. See
model code for setting range.

CG
delivery to maintain volume
requirements of the system at either of
two preselected operating pressures.
Maximum pump delivery is maintained
to approximately 75 psi (PVQ20) or 100
psi (PVQ32) below either pressure
control setting before being reduced.
Control type and pressure range are
designated in the model code.

C**V11B Standard load-sensing and


pressure limiting control with 11 bar
differential pressure (standard factory
setting). Includes bleed-down orifice to
exhaust load-sense signal for
low-pressure standby condition.
C**V11P Same as C**V11B above,
but with bleed-down orifice plugged.
C**VC24B Same as C**V11B, but
with factory differential pressure setting
of 24 bar.
C**VC24P Same as C**V11P, but
with factory differential pressure setting
of 24 bar.

C & CM

Pressure Compensator Control


with Adjustable Maximum
Displacement Stop D
The adjustable maximum stop pressure
control enables the maximum pump
delivery to be externally adjusted from
25% to 100% while maintaining all of the
standard features of a pressure
compensated pump. To assist initial
priming, manual adjustment control
setting must be at least 40% of
maximum flow position.

Remote Control Pressure


Compensator CG
Exactly the same as the C (pressure
compensation option) except the
machine operator is able to change the
compensator setting through the use of
a remote pilot relief valve, such as
Vickers C-175.

CD
Note: Graphic symbols shown with
external valve(s) and cylinder to
illustrate typical usage.

Electric Dual Range Pressure


Compensator Control CD

Load Sensing & Pressure Limiter


Compensator Control

The dual range pressure compensator


control automatically adjusts pump

This compensator provides load sensing


control under all pressure conditions up

18

C**V***B ({orifice open)


& C**V***P ({orifice plugged)

PVQ20 Model Series


Note: To obtain full flow operation of pump, pressure compensator
setting must be 14 bar (200 psi) above desired operating pressure.
Full flow curves were obtained with compensator settings 14 bar
(200 psi) above 210 bar (3000 psi) max. rated pressure.

Volumetric efficiency

Performance Data
Oil type:
SAE 10W
Oil temperature: 49C (120F)
Inlet:
0.2 bar (5 in. Hg)
100%

80%

35 bar (500 psi)


70 bar (1000 psi)
140 bar (2000 psi)
210 bar (3000 psi)

60%

Overall efficiency

100%

80%

70 bar (1000 psi)


140 bar (2000 psi)
210 bar (3000 psi)
35 bar (500 psi)

60%

40%
l/min
40

USgpm
10

24

16

6
35 bar (500 psi)
70 bar (1000 psi)
140 bar (2000 psi)
210 bar (3000 psi)

kW
15
Input power

Delivery

10

hp
20
15

210 bar (3000 psi)


140 bar (2000 psi)
70 bar (1000 psi)
35 bar (500 psi)

10
5

500

1000
Speed r/min

1500

2000

Input power

Delivery

32

19

PVQ32 Model Series


Note: To obtain full flow operation of pump, pressure compensator
setting must be 14 bar (200 psi) above desired operating pressure.
Full flow curves were obtained with compensator settings 14 bar
(200 psi) above 140 bar (2000 psi) max. rated pressure.

Volumetric efficiency

Performance Data
Oil type:
SAE 10W
Oil temperature: 49C (120F)
Inlet:
0.2 bar (5 in. Hg)
100%

80%

35 bar (500 psi)


70 bar (1000 psi)
140 bar (2000 psi)

60%

40%

Overall efficiency

100%

80%

140 bar (2000 psi)


70 bar (1000 psi)
35 bar (500 psi)

60%

40%
l/min
76

USgpm

15

38

19

10

140 bar (2000 psi)


70 bar (1000 psi)
35 bar (500 psi)

Input power

kW
15

15
10

20

hp
20

10

140 bar (2000 psi)


70 bar (1000 psi)
35 bar (500 psi)

500

1000
Speed r/min

1500

2000

Input power

Delivery

57

Delivery

20

Sound Data
Sound Level dB(A)*
Full Stroke
Speed
r/min

Cutoff

Pre
re
Pressure
bar (psi)

PVQ20

PVQ32

PVQ20

PVQ32

35 (500)

53

58

43

47

70 (1000)

56

59

47

50

140 (2000)

57

61

52

54

210 (3000)

59

54

35 (500)

55

61

43

47

70 (1000)

58

62

48

51

140 (2000)

59

63

52

54

210 (3000)

61

55

35 (500)

57

63

47

50

70 (1000)

59

65

51

54

140 (2000)

61

65

56

55

210 (3000)

62

59

35 (500)

60

66

50

53

70 (1000)

62

67

53

56

140 (2000)

63

68

58

62

210 (3000)

64

58

1000

1200

1500

1800

*Sound pressure data equivalent to NFPA Standard.

Temperature: 50C (120F)


Test Fluid:
URSA-ED (10W)
Inlet Pressure: Atmospheric (0 psig)

21

Response Data
Yoke response recorded at rated speed and pressure, 0 psi inlet, 82C (180F), SAE 10W oil. Pressure rise was 6900 bar
(100,000 psi) per second.
PVQ20

PVQ32

Control Type

On stroke

Off stroke

On stroke

Off stroke

Pressure compensator

0.070 sec.

0.023 sec.

0.080 sec.

0.020 sec.

Load sense compensator

0.090 sec.

0.015 sec.

0.100 sec.

0.018 sec.

Thru-drive Shaft Torque Limits


Any deviation from these maximum torque values must be approved by Vickers engineering.

135 (1200)

208 (1850)

PVQ20/32A9

Input Shaft Code


1

Model Series*

Maximum Input
Torque Total
Nm (lb. in.)

337 (2987)

208 (1850)

PVQ20/32A11

337 (2987)

* SAE B 4 inch thru-drive pilot not available in PVQ20/32 frame size.

Vertical Shaft-up Installation S2 Drain Port Option

Additional drain port,


3/ -16 UNF-2B
4

22

58 (517)
(
)

135 (1200)

Maximum Thru-drive
Torque Output
Nm (lb. in.)

29,2
(1.15)

123 (
(1100)
)

Rear Ports, C & CM Controls, No. 1 Shaft

Case drain
connection
.7500-16
UNF-2B
straight thd.
(for 0.50
O.D. tubing)

208
(8.19)

58,7
(2.31)

146
(5.750)
73
(2.88)

9,5
(.375)

6,4 (0.251)
Sq. key
6,3 (0.250)

Compensator
position for R.H.
rotation models

189
123,7 (7.44)
(4.87)
74,7
(2.94)

84,8
(3.34)

33,3
(1.31)

Compensator
position for L.H.
rotation models
28,4
(1.12)D

B 28,4
(1.12)

82,5
(3.25)

101,6 (4.000)
101,5 (3.998)

45,7
(1.80)

66,5
(2.62)

B
65
(2.56)

52,3
(2.06)
22,9
(0.90)
14,3 (0.562)D
2 holes (for mounting)

25,1 (0.989)
24,9 (0.979)

120,6
(4.75)D

12,7
(0.50)

22,22 (0.875)
D
22,20 (0.874)

Right hand rotation

193,8
(7.63)

93,5
(3.68) 186,9
(7.36)

Outlet connection for


L.H. rotation models
1.6250-12 UN-2B thd.
(for 1.25 O.D. tubing)

Outlet connection for


R.H. rotation models
1.6250-12 UN-2B thd.
(for 1.25 O.D. tubing)

Alternate case drain connection


.7500-16 UNF-2B straight thd.
(for 0.50 O.D. tubing)

B Caution while pump is operating


do not back compensator adjustment
screw out beyond dimension shown.

Side Ports

Case drain connection


.7500-16 UNF-2B straight thd.
B 28,4
(for 0.50 O.D. tubing)
(1.12)

174,5
(6.87)

61
(2.40)

108,7
(4.28)

52,4
(2.062)
82,5
(3.25)

31,7
(1.25)

65
(2.56)
Outlet connection for
L.H. rotation models

1.6250-12 UN-2B thd. inlet or


outlet connection 2 places
(for 1.25 O.D. tubing)

196,8
(7.75)

98,5
(3.88)

Outlet connection for


R.H. rotation models

Alternate case drain connection


.7500-16 UNF-2B straight thd.
(for 0.50 O.D. tubing)

No. 3 Shaft

N Shaft with MB Flange


(Flange and shaft end ISO 3019/21000A2HW-E25N)
8,00
7,96
(0.315)
(0.314)
Square key

31,7
(1.25)
22,2
22,1
(0.873)
(0.872)
Major
Dia.

23,8
(0.938)

28,01
27,71
(1.103)
(1.091)

14,25
(0.56)

100
99,95
D
(3.937)
(3.935)
25,006
24,994
D
(0.9845)
(0.9840)

SAE standard involute spline flat root major


diameter fit. 13 teeth 16/32 pitch 0.8125 pitch
diameter (ref.) 0.7335/0.7225 minor diameter

42,0
(1.65)

10,5
(0.413)

9,25
(0.364)

70,00
(2.76)
140,00
(5.51)

23

Remote Compensator CG
Adjustment
1. Turn pressure control (such as
C-175) CCW to minimum setting.
2. Turn compensator adjustment plug
to desired minimum pressure
(17 bar, 250 psi or higher).

Load Sensing with Pressure Limiter C**V****


To mounting face
of pump mtg. flg.

Load sensing comp. control


port location for R.H.
rotation .4375-20 UNF-2B
boss connection

167,39
(6.59)
190,75
(7.51)

3. Full pressure range can now be


obtained with pressure control.
Caution:
Effective compensator pressure will be
CG compensator control setting (1769
bar, 2501000 psig) plus remote relief
valve setting.

Load sensing control port


location for L.H. rotation
28,45
(1.12)
Max.

45,1
(1.775)
19,05
(0.75)

28,45
D
(1.12)
.4375-20 UNF-2B
thread for CG
control models.
Connect to pressure
control, such as
C-175. SAE O-ring
boss connection
.250 O.D. tubing

Compensator adj. knob.


Do not back out adj. knob
beyond 28,4 (1.12) dim.
shown while pump is
operating.

Do not operate pump


with this port plugged.

Pressure Compensator
Control with Adjustable
Max. Displacement Stop D
Adjustment
Loosen locknut on adjusting rod. Turn
adjusting rod clockwise (CW) to
decrease maximum pump delivery or
counterclockwise (CCW) to increase
maximum pump delivery until desired
setting is obtained. Secure this setting
by tightening locknut.

Minimum delivery position


(screw flush with nut) do
not adjust below flush.

226,1
(8.90)

70,9
(2.79)

265,7
(10.46)

118,7
(4.66)
23,9
(0.94)

28,4
D
(1.12)
17,3
(0.68)

52,3
(2.06)

90,2
(3.55)

25,1
(0.99)

Locknut 11,2 (0.44)


across flats

24

Adjusting rod
(Approx. cc/rev
change per turn:
PVQ20 1.88
PVQ32 2.82)

Adjustable maximum stop


pressure compensator control
position on left hand models

28,4
(1.12)

Electric Dual Range


Pressure Compensator
Control CD
Adjustment
1. With the directional valve
de-energized, loosen locknut 5 and
turn the adjusting screw 4 to the
desired first stage pressure setting,
then tighten locknut 5.
2. With solenoid de-energized, turn
adjusting spool 1 counterclockwise
(CCW) until nut 3 is bottomed in
adjusting screw slot. (Second stage
setting is now equal to first stage
pressure setting.) Turn adjusting
spool clockwise (CW) to desired
second stage pressure
requirements. One complete turn of
adjusting spool equals
approximately 41 bar (600 psi).
Energize solenoid and check
pressure setting. De-energize
solenoid and re-adjust if necessary.
Secure this setting by tightening
locknut 2.

318,2
(12.53)

1. Adjusting spool sets


second stage pressure

2. Locknut 17,3 (0.68)


across flats
3. Locknut must be
contained within slot of
adjusting screw as shown
4. Adjusting screw 25,4
(1.00) across flats sets
first stage pressure

5. Locknut 31,7 (1.25)


across flats

134,9
(5.31)

158,7
(6.25)

52,3
(2.06)

Dual range pressure


compensator position

Position for
L.H. models

Electrical conduit
conn. 1/2 NPTF thd.

Solenoid Data (110V AC 50 Hz and 115/120V AC 60 Hz)


Solenoid current
115/120V AC 60 Hz
110V AC 50 Hz

Inrush amps
(R.M.S.)
2.0

Holding amps
.54
.64*

* Maximum peak inrush amps approximately 1.4 x R.M.S. value shown.

Refer to catalog GB-C-2015B for additional solenoid valve data.


Note: Any sliding spool valve, if held

shifted under pressure for long periods


of time, may stick and not spring return
due to fluid residue formation and,
therefore, should be cycled periodically
to prevent this from happening.

25

Electric Dual Range


Pressure Compensator with
Maximum Displacement
Stop CD**D
Maximum Flow Adjustment
With the system pressure below both
compensator settings, loosen maximum
stop adjusting screw locknut and adjust
screw to desired flow position (turning
screw clockwise decreases flow and
turning screw counterclockwise
increases flow). To lock screw in
position, tighten locknut. To assist initial
priming, adjust control setting to at least
40% of maximum flow position.

Compensator Control
1. With the directional valve
de-energized, loosen locknut 5 and
turn the adjusting screw 4 to the
desired first stage pressure setting,
then tighten locknut 5.
2. With directional valve de-energized,
turn adjusting spool 1
counterclockwise until nut 3 is
bottomed in adjusting screw slot.
(Second stage setting is now equal
to first stage pressure setting.) Turn
adjusting spool clockwise to desired
second stage pressure
requirements. One complete turn of
adjusting spool equals
approximately 41 bar (600 psi).
Energize solenoid and check
pressure setting. De-energize
solenoid and re-adjust if necessary.
Secure this setting by tightening
locknut 2.

201,7
(7.94)

Position for
L.H. models

25,1
(0.99)
23,9
(0.94)

52,3
(2.06)
Minimum delivery
position (flush with
nut). Do not adjust
below flush.

Maximum stop (adjusting screw)


.250-20 UNC thd.
Maximum delivery position

1. Adjusting spool sets


second stage pressure

215,1
(8.47)

2. Locknut 17,3 (0.68)


across flats

93,5
(3.68)

3. Locknut must be
contained within slot of
adjusting screw as shown

4. Adjusting screw 25,4


(1.00) across flats sets
first stage pressure
5. Locknut 31,7 (1.25)
across flats

144,5
(5.69)

Solenoid Data (110V AC 50 Hz and 115/120V AC 60 Hz)


Solenoid current
115/120V AC 60 Hz
110V AC 50 Hz

Inrush amps
(R.M.S.)
2.0

Holding amps
.54
.64*

* Maximum peak inrush amps approximately 1.4 x R.M.S. value shown.

Refer to catalog GB-C-2015B for additional solenoid valve data.


Note: Any sliding spool valve, if held

shifted under pressure for long periods


of time, may stick and not spring return
26

Electrical conduit
connection 1/2 NPTF thd.

Locknut 11,2 (0.44) across flats

due to fluid residue formation and,


therefore, should be cycled periodically
to prevent this from happening.

192,3
(7.57)

Unloading Valve Control UV


With the unloading valve control the
variable pump will unload at a preset
pressure. The pump will maintain this no
flow, low pressure (approximately 14 bar
[200 psi]) standby condition, until
system pressure drops to about 85% of
the preset unloading pressure. The
pump will then return on stroke and
provide full flow until the preset
unloading pressure is reached again.
With this control, an efficient
accumulator charging circuit is obtained.
The pump will provide full flow to fill the
accumulator until the maximum
charging pressure is reached. The
pump then goes to a standby condition
until the accumulator pressure drops to
85% of the desired maximum. The
accumulator is then recharged as the
cycle starts over again.
A separate right angle check valve must
be provided to maintain the accumulator
hydraulic charge and prevent back flow
when the pump is unloaded. The check
valves internal leakage must not
exceed five drops per minute. The
control port must be connected to
system pressure, downstream of the
check valve.

Unload valve
control port
To load

Inlet

Check Valve

Outlet
Drain

Setting Pressures
1. Back out accumulator unloading
pressure adjustment screw to below
desired unloading pressure.
2. Adjust desired standby pressure.

Adjustment range
PVQ20 100210 bar (15003000 psi)
PVQ32 100140 bar (15002000 psi)

3. Set accumulator pressure by


screwing in the accumulator
unloading adjustment screw.
Accumulator recharge (cut-in)
pressure is a function of the
maximum accumulator pressure
and is not adjustable.

Cut-in pressure is 85% of unloading


pressure, minimum.

4. Check pressure settings and


re-adjust if necessary.
Standby pressure
adjustment
Control Port .4375-20
UNF-2B thd. SAE O-ring boss
connection .25 OD tubing

Accumulator unloading
pressure adjustment
246,4
(9.70)
174,5
(6.87)
174,5
(6.87)

145,5
(5.95)

82,5
(3.25)

52,4
(2.06)

65,0
(2.56)

56,1
(2.21)

27

A9 & A11 SAE A Thru-Drives


No. 1 shaft. Input torque not to exceed 73 Nm (650 lb. in.)
plus tabulated auxiliary pump torque with no overhung load.
Applications requiring overhung load capability or other
shaft ends are subject to approval by Vickers Engineering.

Note: Ports are reversed for


L.H. rotation.
Control location same for
both L.H. and R.H. rotation.

101,6 (4.00)
101,5 (3.998)
6,4 (0.251)
6,3 (0.250)

22,22 (0.875)
22,20 (0.874)

187
(7.36)

174,7
(6.88)

93,5
(3.68)
11,2
(0.44)

4,8
(0.188)

18,7 (0.738)
14,3
18,5 (0.729)
(0.562)
9,6
2 places 25,1 (0.989)
(0.39)
24,9 (0.979)

146,05
(5.75)

110,2
96 (4.34)
(3.78)

76,7
(3.02)

74,7
(2.94)
Output spline
(see table)

Thru-Drive
Cutaway View

Caution: While pump is operating,


do not back compensator adj. out
20,6
beyond 28,4 (1.12) dim. shown.
(0.81)
Construction plug. Do not remove.
Drain port .7500-16 UNF-2B thd. SAE
129,3
O-ring boss conn. .500 O.D. tubing.
(5.09)
28,4
Drain port .7500-16
7,9
(1.12)
UNF-2B thd. SAE O-ring (0.31)
boss conn. .500 O.D. tubing
.375-16 UNC-2B thd.
18,3 (0.72) deep

82,5
(3.25)

31,7
(1.25)

73,1
(2.88)

166,1
(6.54)
123,4
(4.86)

47,5
(1.87)

120,6
(4.75)

20,6
(0.81)

12,7
(0.50)
162
(6.38)

106,4
(4.19)
98,5
(3.88)

230,6
(9.08)

196,8
(7.75)

Inlet port R.H. see


note. 1.6250-12
UN-SAE str. thd.
SAE O-ring boss
connection 1.250
O.D. tubing

82,6

(3.252)
Use O-ring AS568-042 at interface
of auxiliary pump mounting

Outlet port R.H.


see note.
1.6250-12 UN-2B
thd. SAE O-ring
boss connection
1.250 O.D. tubing

Alternate drain port


.7500-16 UNF-2B
thd. SAE O-ring
boss connection
.500 O.D. tubing

A
See table
B

Model Series

ANS B92.1-1970
11 teeth 16/32 DP
Flat root side fit

Coupling Kit

16,7 (0.66)

33,0 (1.30)

02-136810

123 (1100)

ASA B5.15-1960
9 teeth 16/32 DP
Flat root side fit

A11

Installation Dimensions mm (in)

58 (517)

Spline Data

A9

Max. Torq e
Max Torque
Nm (in. lb.)

18,5 (0.73)

39,1 (1.54)

02-306041

Note: O-ring included with pump. Coupling kit, cap screws, and washers must be ordered separately to mount rear pump.

Typical Rear Pumps (with shaft codes) for PVQ20/32 Thru-Drives


Model
Series

Rear Pump
Shaft Code

PVQ10/13

PVB5/6

S124 suffix

V10

11

V20

A9

Typical Rear Pump

62

Note: A11 (not listed above) is intended for special application only.

28

Thru-drive
Coupling Kit

02-136810
02 136810

PVQ25 Model Series

Ratings
Model
Series

Maximum Geometric
Displacement
cm3/r (in3/r)

Rated
Speed
r/min

Maximum
Pressure
bar (psi)

Input Power at Max.


Pressure & Rated Speed
kW (hp)

Approx.
Weight
kg (lb)

PVQ25

25,2 (1.54)

1800

210 (3000)

16 (24)

14 (31)

Pressure Limits
Case pressure 0,35 bar (5 psig) maximum
Inlet pressure 0,2 bar (5 in. Hg) vacuum to 2 bar (30 psig)

Model Code

1
1

P
V
Q
2

R
L
5

1
3
N

20 Design number subject to change.


Installation dimensions remain
unchanged for designs 2029.

Pump design number

Displacement in cc/rev and pressure


ratings

Mounting flange specifications

Rotation viewed from shaft end

CM**

C**V**B

Right hand (cw), standard


Left hand (ccw), optional
Ports, type and location

Shafts, input

C**V**P

Straight keyed SAE B modified,


2.31 long
Splined SAE B modified, 13T
16/32 DP major dia. fit
Shaft end ISO 3019/2 E25N (available
with MB mount only)

C**VC**B

Seals
Buna N, standard

10

11

C**VC**P

CG

Control type

C**

SE SAE O-ring rear port, 1.0625 inlet


& outlet (standard)
6

Inline piston pump


Variable volume
Quiet series

B2 Flange SAE J744 101-2 (SAE B)


MB Flange ISO 3019/2-100A2HW
(available with N drive shaft only)
4

Series PVQ

25 25,2 cc/rev (1.54 cir), 210 bar


(3000 psi)
3

Pressure compensator.
Standard setting 21 in tens of
bar (max. setting 201 bar).
Range 0221 in tens of bar.
Pressure compensator.
Standard setting, 10 in tens of
bar (max. setting 103 bar).
Range 0210 in tens of bar
(3501500 psi).
Pressure compensator C**, as
above with load sensing.
Standard load sensing setting
is 11 bar (160 psi); range
1017 bar (150250 psi); with
bleed-down orifice. Example:
C21V11B indicates PVQ25
compensator with 210 bar
pressure setting and 11 bar
load-sense differential.
Pressure compensator with
load sensing as C**V**B
above, but with bleed-down
orifice plugged.
Pressure compensator with
load sensing. Compensator
same as C** above. Standard
load sensing setting is 24 bar
(350 psi), range 1731 bar
(250450 psi). With
bleed-down orifice.

CD**

UV

10

12

Pressure compensator with


load sensing. Same as
C**VC**B above, but with
bleed-down orifice plugged.
Pressure compensator
modified for hydraulic remote
control.
Electric dual range
compensator. PVQ25: CD21
is standard 210 bar setting of
high range (24210 bar). Unit
requires low range to be set
by customer (20100 bar).
Unloading Valve for
accumulator circuits. See
installation details.

Control option

Blank Without adjustable maximum


displacement stop (standard)
D
Adjustable maximum displacement
stop (optional)
11

10
11
12
20
12

Control design

C** and CM**


C**D and CM**D
C**V(C)**B and C**V(C)**P
CD**, CG, and UV

Special suffixes

S2 Shaft up mounting
S3 British Standard Parallel Threads
Counterbore Ports (ISO R288 threads).
Contact Vickers for available
configurations.
S9 Special CG compensator for use with
electronically modulated relief valves

29

adjusts pump flow in response to a


remote pressure signal and maintains
outlet pressure at a level slightly above
load pressure. The integral pressure
limiter overrides the load sensing
control, reducing pump displacement as
the preset maximum operating pressure
is reached.

Pressure Compensator Controls


C & CM
The pressure compensator control
automatically adjusts pump delivery to
maintain volume requirements of the
system at a preselected operating
pressure. Maximum pump delivery is
maintained to approximately 75 psi
(PVQ25) below the pressure setting
before being reduced. The pressure
compensator control operates on one side
of center and has an adjustment range as
designated in the model coding.

Standard load-sense differential pressure


settings, by control type, follow. See
model code for setting range.

CG
requirements of the system at either of
two preselected operating pressures.
Maximum pump delivery is maintained
to approximately 75 psi (PVQ25) below
either pressure control setting before
being reduced.
Control type and pressure range are
designated in the model code.

C**V11B Standard load-sensing and


pressure limiting control with 11 bar
differential pressure (standard factory
setting). Includes bleed-down orifice to
exhaust load-sense signal for
low-pressure standby condition.
C**V11P Same as C**V11B above,
but with bleed-down orifice plugged.
C**VC24B Same as C**V11B, but
with factory differential pressure setting
of 24 bar.
C**VC24P Same as C**V11P, but
with factory differential pressure setting
of 24 bar.

C & CM

Pressure Compensator Control


with Adjustable Maximum
Displacement Stop D
The adjustable maximum stop pressure
control enables the maximum pump
delivery to be externally adjusted from
25% to 100% while maintaining all of the
standard features of a pressure
compensated pump. To assist initial
priming, manual adjustment control
setting must be at least 40% of
maximum flow position.

Remote Control Pressure


Compensator CG
Exactly the same as the C (pressure
compensation option), except the
machine operator is able to change the
compensator setting through the use of
a remote pilot relief valve, such as
Vickers C-175.

CD
Note: Graphic symbols shown with
external valve(s) and cylinder to
illustrate typical usage.

Electric Dual Range Pressure


Compensator Control CD

Load Sensing & Pressure Limiter


Compensator Control

The dual range pressure compensator


control automatically adjusts pump
delivery to maintain volume

This compensator provides load sensing


control under all pressure conditions up
to the desired maximum. It automatically

30

C**V***B ({orifice open)


& C**V***P ({orifice plugged)

Performance at 1800 r/min


Oil type: SAE 10W
Oil temp: 50_ C (120_ F)
Inlet pressure: 0 psi

100%
Volumetric efficiency
Efficiency

90%
kW (hp)
16,8 (22.5)

Overall efficiency

80%
70%

14,9 (20.0)

60%

13,0 (17.5)
Input power

9,3 (12.5)

Delivery

l/min (USgpm)
47,3 (12.5)

Delivery

7,5 (10.0)

Input power

11,2 (15.0)

50%

5,6 (7.5)

37,9 (10.0)
Input power pump compensated

3,7 (5.0)

28,4 (7.5)

1,9 (2.5)
0

35
(500)

70
(1000)

100
(1500)

140
(2000)

175
(2500)

0
210
(3000)

Outlet pressure bar (psi)

31

Sound Data
Speed
r/min

Sound Level dB(A)*


Full Stroke

Cutoff

35 (500)

56.5

54.9

70 (1000)

57.7

58.3

100 (1500)

58.6

60.0

140 (2000)

59.5

61.3

175 (2500)

60.9

62.0

210 (3000)

66.6

63.1

35 (500)

60.9

56.9

70 (1000)

1000

Press re
Pressure
bar (psi)

62.4

60.1

100 (1500)

63.6

63.8

64.5

63.8

65.5

35 (500)

61.9

57.7

70 (1000)

63.5

61.9

100 (1500)

64.2

62.7

140 (2000)

65.3

63.3

175 (2500)

65.1

64.7

210 (3000)

65.9

65.3

35 (500)

64.0

59.0

70 (1000)

65.2

62.0

100 (1500)

66.0

63.4

140 (2000)

67.1

64.4

175 (2500)

67.5

65.7

210 (3000)

1800

62.3

63.3

210 (3000)

1500

63.1

140 (2000)
175 (2500)

1200

67.4

66.6

*Sound pressure data equivalent to NFPA Standard.

Temperature: 50C (120F)


Test Fluid:
URSA-ED (10W)
Inlet Pressure: Atmospheric (0 psig)

Response Data
Yoke response recorded at rated speed and pressure, 0 psi inlet, 82C (180F),
SAE 10W oil. Pressure rise was 6900 bar (100,000 psi) per second.
Control Type

On stroke

Off stroke

Pressure compensator

0.030 sec.

0.012 sec.

Load sense compensator

0.040 sec.

0.012 sec.

32

Remote Compensator CG
Adjustment
1. Turn pressure control (such as C-175)
CCW to minimum setting.
2. Turn compensator adjustment plug to
desired minimum pressure (17 bar,
250 psi or higher).

Load Sensing with Pressure Limiter C**V****


To mounting face
of pump mtg. flg.

Load sensing comp. control


port location for R.H.
rotation .4375-20 UNF-2B
boss connection

167,39
(6.59)
190,75
(7.51)

3. Full pressure range can now be


obtained with pressure control.
Caution:
Effective compensator pressure will be
CG compensator control setting (1769
bar, 2501000 psig) plus remote relief
valve setting.

Load sensing control port


location for L.H. rotation
28,45
(1.12)
Max.

45,1
(1.775)
19,05
(0.75)

28,45
D
(1.12)
.4375-20 UNF-2B
thread for CG
control models.
Connect to pressure
control, such as
C-175. SAE O-ring
boss connection
.250 O.D. tubing

Compensator adj. knob.


Do not back out adj. knob
beyond 28,4 (1.12) dim.
shown while pump is
operating.

Do not operate pump


with this port plugged.

Pressure Compensator
Control with Adjustable
Max. Displacement Stop D
Adjustment
Loosen locknut on adjusting rod. Turn
adjusting rod clockwise (CW) to
decrease maximum pump delivery or
counterclockwise (CCW) to increase
maximum pump delivery until desired
setting is obtained. Secure this setting
by tightening locknut.

52,0
72,6 (2.05)
(2.86)
28,4

(1.12)

90,1
(3.55)

Locknut
11,2 (0.44) across flats
63,8
(2.51)

123,8
(4.87)

30,0
(1.18)

28,4
(1.12)

11,0
Max.
(0.43)

Adjusting screw
23,8 (0.90) across flats

Control position for


right hand rotation

Maximum stop
adjusting rod
(Approx. 2.22 cc/rev
change per turn)

Control position for


left hand rotation

220,2
196,2 (8.67)
(7.72)

252,1
(9.93)

Dimensions
to flange face

33

Electric Dual Range


Pressure Compensator
Control CD

Dimension from
flange face

Adjustment
1. With the directional valve
de-energized, loosen locknut 5 and
turn the adjusting screw 4 to the
desired first stage pressure setting,
then tighten locknut 5.
2. With solenoid de-energized, turn
adjusting spool 1 counterclockwise
(CCW) until nut 3 is bottomed in
adjusting screw slot. (Second stage
setting is now equal to first stage
pressure setting.) Turn adjusting
spool clockwise (CW) to desired
second stage pressure
requirements. One complete turn of
adjusting spool equals
approximately 41 bar (600 psi).
Energize solenoid and check
pressure setting. De-energize
solenoid and re-adjust if necessary.
Secure this setting by tightening
locknut 2.

312,1
(12.29)

1. Adjusting spool sets


second stage pressure

2. Locknut 17,3 (0.68)


across flats
3. Locknut must be
contained within slot of
adjusting screw as shown
4. Adjusting screw 25,4
(1.00) across flats sets
first stage pressure

5. Locknut 31,7 (1.25)


across flats

126,6
(4.98)

186,6
(7.35)

52,0
(2.05)

Dual range pressure


compensator position

Position for
R.H. models

Electrical conduit
conn. 1/2 NPTF thd.

Solenoid Data (110V AC 50 Hz and 115/120V AC 60 Hz)


Solenoid current
115/120V AC 60 Hz
110V AC 50 Hz

Inrush amps
(R.M.S.)
2.0

Holding amps
.54
.64*

* Maximum peak inrush amps approximately 1.4 x R.M.S. value shown.

Refer to catalog GB-C-2015B for additional solenoid valve data.


Note: Any sliding spool valve, if held

shifted under pressure for long periods


of time, may stick and not spring return
due to fluid residue formation and,
therefore, should be cycled periodically
to prevent this from happening.

34

Electric Dual Range


Pressure Compensator with
Maximum Displacement
Stop CD**D

Dimension from
flange face

Maximum Flow Adjustment


With the system pressure below both
compensator settings, loosen maximum
stop adjusting screw locknut and adjust
screw to desired flow position (turning
screw clockwise decreases flow and
turning screw counterclockwise
increases flow). To lock screw in
position, tighten locknut. To assist initial
priming, adjust control setting to at least
40% of maximum flow position.

Compensator Control
1. With the directional valve
de-energized, loosen locknut 5 and
turn the adjusting screw 4 to the
desired first stage pressure setting,
then tighten locknut 5.
2. With directional valve de-energized,
turn adjusting spool 1
counterclockwise until nut 3 is
bottomed in adjusting screw slot.
(Second stage setting is now equal
to first stage pressure setting.) Turn
adjusting spool clockwise to desired
second stage pressure
requirements. One complete turn of
adjusting spool equals
approximately 41 bar (600 psi).
Energize solenoid and check
pressure setting. De-energize
solenoid and re-adjust if necessary.
Secure this setting by tightening
locknut 2.

196,2
(7.72)

Position for
L.H. models

25,1
(0.99)
30,0
(1.18)

52,3
(2.06)

Locknut 11,2 (0.44) across flats

Minimum delivery
position (flush with
nut). Do not adjust
below flush.

Maximum stop (adjusting screw)

Electrical conduit
connection 1/2 NPTF thd.
Maximum stop
adjusting rod
(Approx. 2.22 cc/rev
change per turn)

.250-20 UNC thd.


Maximum delivery position

213,4
(8.40)

1. Adjusting spool sets


second stage pressure

2. Locknut 17,3 (0.68)


across flats

93,5
(3.68)

3. Locknut must be
contained within slot of
adjusting screw as shown
4. Adjusting screw 25,4
(1.00) across flats sets
first stage pressure
5. Locknut 31,7 (1.25)
across flats
136,3
(5.37)

196,3
(7.73)

Solenoid Data (110V AC 50 Hz and 115/120V AC 60 Hz)


Solenoid current
115/120V AC 60 Hz
110V AC 50 Hz

Inrush amps
(R.M.S.)
2.0

Holding amps
.54
.64*

* Maximum peak inrush amps approximately 1.4 x R.M.S. value shown.

Refer to catalog GB-C-2015B for additional solenoid valve data.


Note: Any sliding spool valve, if held

shifted under pressure for long periods


of time, may stick and not spring return

due to fluid residue formation and,


therefore, should be cycled periodically
to prevent this from happening.

35

Unloading Valve Control UV


With the unloading valve control the
variable pump will unload at a preset
pressure. The pump will maintain this no
flow, low pressure (approximately 14 bar
[200 psi]) standby condition, until
system pressure drops to about 85% of
the preset unloading pressure. The
pump will then return on stroke and
provide full flow until the preset
unloading pressure is reached again.
With this control, an efficient
accumulator charging circuit is obtained.
The pump will provide full flow to fill the
accumulator until the maximum
charging pressure is reached. The
pump then goes to a standby condition
until the accumulator pressure drops to
85% of the desired maximum. The
accumulator is then recharged as the
cycle starts over again.
A separate right angle check valve must
be provided to maintain the accumulator
hydraulic charge and prevent back flow
when the pump is unloaded. The check
valves internal leakage must not
exceed five drops per minute. The
control port must be connected to
system pressure, downstream of the
check valve.

Unload valve
control port
To load

Inlet

Check Valve

Outlet
Drain

Setting Pressures
1. Back out accumulator unloading
pressure adjustment screw to below
desired unloading pressure.
2. Adjust desired standby pressure.

Adjustment range
PVQ25 100210 bar (15003000 psi)

3. Set accumulator pressure by


screwing in the accumulator
unloading adjustment screw.
Accumulator recharge (cut-in)
pressure is a function of the
maximum accumulator pressure
and is not adjustable.

Cut-in pressure is 85% of unloading


pressure, minimum.

4. Check pressure settings and


re-adjust if necessary.

196,6
(7.74)

Accumulator unloading
pressure adjustment

167,5
(6.59)

Control Port .4375-20


UNF-2B thd. SAE O-ring boss
connection .25 OD tubing

Standby pressure
adjustment

52,0
(2.05)
41,1
(1.62)
145,5
(5.95)

162,5
(6.40)
272,8
(10.74)

36

PVQ25 with C-type Control, No. 3 Shaft


Note: Ports are reversed
for L.H. rotation.
R.H. rotation
25,0
(0.98)
14,53
14,15
(0.572)
(0.557)

14,0 R
2 places
(0.55 R)
0,8
max. R
(0.03)

73,0
(2.87)

70,0
(2.76)
140,0
(5.51)

146,0
(5.75)

51,5
(2.03)

120,6
(4.75)

30,0
(1.18)

19,5 R
(0.77 R)

9.4
(0.37)
14,0
(0.55)

Outlet port B (see note) 1.0625-12 UN-2B thd.


SAE O-ring boss connection .750 O.D. tubing
(Shown for R.H. rotation)

196,6
(7.74)
167,5
(6.59)

44,0
(1.73)

60,0
(2.36)

101,60 30_
101.55
(4.000)
(3.998)

83,1
(3.27)

44,0
(1.73)
Drain port D2
.750-16 UNF-2B thd.
SAE O-ring boss
connection .500
O.D. tubing
56,0
2 places
(2.20)

47,0
(1.85)
28,4
(1.12)

52,0
70,0
(2.05) (2.76)

79,2
(3.12)

1.5
x 45_
(0.06)
162,5
(6.40)

#2 shaft

114,1
(4.49)

186,1
(7.33)

19,0
(0.75)
33,3
(1.31)

77,0
(3.03)
154,0
(6.06)

Compensator position for R.H. rotation


(Reverse for L.H. rotation)

41,1
(1.62)

Inlet port A (see note) 1.625-12 UN-2B thd.


SAE O-ring boss connection 1.250 O.D. tubing
(Shown for R.H. rotation)

29,5
(1.16)

Construction plugs
Do not remove

85,1
(3.35)

27,0
(1.06)

170,2
(6.70)

Alternate drain port D1


.750-16 UNF-2B thd.
SAE O-ring connection
.500 O.D. tubing

153,5
(6.04)

No. 1 Shaft

N Shaft with MB Flange


(Flange and shaft end ISO 3019/21000A2HW-E25N)

22,225
22,200
(0.8750)
(0.8740)

6,375
6,350
31,75
x
lg. key
(0.251) (1.250)
(0.250)
58,6
(2.31)

25,12
24,87
(0.989)
(0.979)

8,00
7,96
(0.315)
(0.314)
Square key

28,01
27,71
(1.103)
(1.091)
100
99,95
D
(3.937)
(3.935)
25,006
24,994
D
(0.9845)
(0.9840)

14,25
(0.56)

42,0
(1.65)

#1 shaft
1.5
x 45_
(0.06)

50.8
(2.00)

10,5
(0.413)

9,25
(0.364)

70,00
(2.76)
140,00
(5.51)

37

PVQ25 C**V(C)**P/B Load Sensing


with Pressure Limiter
196,6
(7.74)
167,5
(6.59)

52,0
(2.05)
28,4
(1.12)

162,5
(6.40)

71,0
(2.80)

19,0
(0.75)

70,6
(2.78)
Compensator position
for L.H. rotation

214,3
(8.44)

79,2
(3.12)

Load sensing
control port location
for L.H. rotation

77,0
(3.03)

Compensator position
for R.H. rotation

128,3
(5.05)

Load sensing com. control port for


R.H. rotation .4375-20 UNF-2B thd.
SAE O-ring boss connection .250
O.D. tubing

154,0
(6.06)

10,6
(0.42)
68,3
27,0 (2.69)
(1.06)
28,4
Max.
(1.12)
153,5
(6.04)
192,9
(7.59)

Caution: While pump is operating,


do not back out adjusting screw
beyond dimension shown.

PVQ25 CG Remote
Adjustment Compensator
196,6
(7.74)
167,5
(6.59)

52,0
(2.05)

162,5
(6.40)
186,1
(7.33)

28,4
(1.12)

75,1
(2.96)
114,8
(4.52)

153,5
(6.04)

38

15,1
(0.59)
58,4
(2.16)

Compensator position
for R.H. rotation
Load sensing com. control port for
R.H. rotation .4375-20 UNF-2B thd.
SAE O-ring boss connection .250
O.D. tubing

PVQ40 & PVQ45 Model Series

Ratings
Model
Series

Maximum Geometric
Displacement
cm3/r (in3/r)

Rated
Speed
r/min

Maximum
Pressure
bar (psi)

Input Power at Max.


Pressure & Rated Speed
kW (hp)

Approx.
Weight
kg (lb)

PVQ40

41,5 (2.500)

1800

210 (3000)

27,6 (37)

20,6 (45.4)

PVQ45

45,1 (2.750)

1800

186 (2700)

28,3 (38)

20,6 (45.4)

Pressure Limits
Inlet pressure 0,2 bar (5 in. Hg) vacuum to 2 bar (30 psig)
Case pressure 0,35 bar (5 psig) maximum

Note: Integral relief valve limits case pressure peaks to 0,7 bar (10 psi) higher
than inlet pressure to protect pump. Flow from valve is returned directly to pump
inlet. Use of case drain line required to limit steady-state case pressure.

Model Code

1
1

P
V
Q
2

Series PVQ
Inline piston pump
Variable volume
Quiet series
Displacement in cc/rev and pressure
ratings

40 41, cc/rev (2.50 cir), 210 bar


(3000 psi)
45 45,1 cc/rev (2.75 cir), 186 bar
(2700 psi)
3

Mounting flange specifications

B2 Flange SAE J744 101-2 (SAE B)


MB Flange ISO 3019/2-100A2HW
(available with N drive shaft only)

R
L
5

Rotation viewed from shaft end


Right hand (cw), standard
Left hand (ccw), optional
Thru-drive without coupling
(available with side ports only)

Blank
A9
A11
B26
6

No thru-drive
SAE J744 82-2 (SAE A) w/9T spline
SAE J744 82-2 (SAE A) w/11T spline
SAE J744 101-2 (SAE B) w/26T spline

Ports, type and location

SE SAE O-ring rear port, (standard)


SS SAE O-ring side port, (optional)
FS SAE 4-bolt, side ports (Preferred for
SAE A thru-drive. Not available on
SAE B thru-drive.)
7

1
2
3
4

Shafts, input
Straight keyed SAE B modified, 1.75
long (not available on thru-drive)
Straight keyed, SAE B-B modified
Splined SAE B modified, 13T
16/32 DP flat root side fit
Splined SAE B-B modified 15T
16/32 DP flat root side fit

Shaft end ISO 3019/2 E25N (available


with MB mount only)
28 26 tooth splined shaft (Vickers). Used
in PVQ40/45 single to mount on
PVQ40/45 B26 thru-drive.
8

Seals

S
F

Buna N, standard
Fluorocarbon, optional

Pump design number

10 Design number subject to change.


Installation dimensions remain
unchanged for designs 1019.
10

C**
4

Control type

Pressure compensator. PVQ40:


Standard model is C21, indicating
setting of 210 bar (3000 psi); range
is 0221 in tens of bar (3503000
psi). PVQ45: Standard model is
C19, indicating factory setting of
186 bar (2700 psi); range is 0219
in tens of bar (3502700 psi).
CM** Low pressure compensator.
Standard model is CM7, indicating
factory setting of 70 bar (1000 psi);
range is 0210 in tens of bar
(3501500 psi).
C**V**B
Pressure compensator C**, as
above with load sensing.
Standard load sensing setting
is 11 bar (160 psi); range
1017 bar (150250 psi); with
bleed-down orifice. Example:
C21V11B indicates PVQ40
compensator with 210 bar
pressure setting and 11 bar
load-sense differential.
C**V**P
Pressure compensator with
load sensing as C**V**B
above, but with bleed-down
orifice plugged.

10

11

12

13

C**VC**B

Pressure compensator with


load sensing. Compensator
same as C** above. Standard
load sensing setting is 24 bar
(350 psi), range 1731 bar
(250450 psi). With
bleed-down orifice.
C**VC**P Pressure compensator with
load sensing. Same as
C**VC**B above, but with
bleed-down orifice plugged.
CG
Pressure compensator modified for
hydraulic remote control.
CD** Electric dual range compensator.
PVQ40: CD21 is standard 210 bar
setting of high range (24207 bar).
PVQ45: CD19 is standard 190 bar
setting of high range (24190 bar).
Both units require low range to be
set by customer (20100 bar).
UV
Unloading Valve for accumulator
circuits. See installation details.
11

Control option

Blank Without adjustable maximum


displacement stop (standard)
D
Adjustable maximum displacement
stop (optional)
12

10
11
12
20
13

Control design

C** and CM**


C**D and CM**D
C**V(C)**B and C**V(C)**P
CD**, CG, and UV

Special suffixes

S2 Shaft up mounting
S3 British Standard Parallel Threads
Counterbore Ports (ISO R288 threads).
Contact Vickers for available
configurations.
S9 Special CG compensator for use with
electronically modulated relief valves

39

outlet pressure at a level slightly above


load pressure. The integral pressure
limiter overrides the load sensing
control, reducing pump displacement as
the preset maximum operating pressure
is reached.

Pressure Compensator Controls


C & CM
This control automatically varies pump
displacement to meet the system flow
demand for a constant system pressure.
Displacement starts to reduce to zero
within 14 bar (200 psi) of the
compensator setting. Power draw-off is
minimized, therefore, system relief
valves should not be required.

Standard load-sense differential pressure


settings, by control type, follow. See
model code for setting range.

CG
Maximum pump delivery is maintained
to approximately 3,4 bar (50 psi) below
either pressure control setting before
being reduced.
Control type and pressure range are
designated in the model code.
C & CM

C**V11B Standard load-sensing and


pressure limiting control with 11 bar
differential pressure (standard factory
setting). Includes bleed-down orifice to
exhaust load-sense signal for
low-pressure standby condition.
C**V11P Same as C**V11B above,
but with bleed-down orifice plugged.
C**VC24B Same as C**V11B, but
with factory differential pressure setting
of 24 bar.
C**VC24P Same as C**V11P, but
with factory differential pressure setting
of 24 bar.

Pressure Compensator Control


with Adjustable Maximum
Displacement Stop D
The adjustable maximum stop pressure
control enables the maximum pump
delivery to be externally adjusted from
25% to 100% while maintaining all of the
standard features of a pressure
compensated pump. To assist initial
priming, manual adjustment control
setting must be at least 40% of
maximum flow position.

Remote Control Pressure


Compensator CG
Exactly the same as the C (pressure
compensation option) except the
machine operator is able to change the
compensator setting through the use of
a remote pilot relief valve.

Electric Dual Range Pressure


Compensator Control CD
The dual range pressure compensator
control automatically adjusts pump
delivery to maintain volume
requirements of the system at either of
two preselected operating pressures.

40

CD

Note: Graphic symbols shown with


external valve(s) and cylinder to
illustrate typical usage.

Load Sensing & Pressure Limiter


Compensator Control
This compensator provides load sensing
control under all pressure conditions up
to the desired maximum. It automatically
adjusts pump flow in response to a
remote pressure signal and maintains

C**V***B ({orifice open)


& C**V***P ({orifice plugged)

PVQ40 Model Series

Volumetric efficiency

Performance Data
Oil type:
SAE 10W
Oil temperature: 82C (180F)
Inlet:
0 psi

Note: To obtain full flow operation of pump, pressure compensator


setting must be 14 bar (200 psi) above desired operating pressure.
Full flow curves were obtained with compensator settings 14 bar
(200 psi) above 210 bar (3000 psi) max. rated pressure.

100%

80%

210 bar (3000 psi)


140 bar (2000 psi)
70 bar (1000 psi)
35 bar (500 psi)

60%

40%

Overall efficiency

100%
140 bar (2000 psi)
70 bar (1000 psi)
80%
35 bar (500 psi)
210 bar (3000 psi)
60%

40%
USgpm

l/min
76

20

38

19

10
35 bar (500 psi)
70 bar (1000 psi)
140 bar (2000 psi)
210 bar (3000 psi)

0
hp
60

Input power

kW
45

45
30

15

Delivery

15

30

210 bar (3000 psi)


140 bar (2000 psi)
70 bar (1000 psi)
35 bar (500 psi)
500

15

1000
Speed r/min

1500

2000

Input power

Delivery

57

41

PVQ45 Model Series

Volumetric efficiency

Performance Data
Oil type:
SAE 10W
Oil temperature: 82C (180F)
Inlet:
0 psi
100%

80%

Note: To obtain full flow operation of pump, pressure compensator


setting must be 14 bar (200 psi) above desired operating pressure.
Full flow curves were obtained with compensator settings 14 bar
(200 psi) above 186 bar (2700 psi) max. rated pressure.

140 bar (2000 psi)


70 bar (1000 psi)
35 bar (500 psi)
186 bar (2700 psi)

60%

100%

80%

35 bar (500 psi)


70 bar (1000 psi)
140 bar (2000 psi)
186 bar (2700 psi)

60%
USgpm

l/min
95

25

20

57

15

38

19

35 bar (500 psi)


70 bar (1000 psi)
140 bar (2000 psi)
186 bar (2700 psi)

10

0
hp
60

Input power

kW
45

45
30

15

42

Delivery

Delivery

76

30

186 bar (2700 psi)


140 bar (2000 psi)
70 bar (1000 psi)
35 bar (500 psi)
500

15

1000
Speed r/min

1500

2000

Input power

Overall efficiency

40%

Sound Data
Speed
r/min

Sound Level dB(A)**

Press re
Pressure
bar (psi)

Full Stroke

Cutoff

35 (500)

60

58

70 (1000)

65

65

61

60

62

62

140 (2000)

65

65

210 (3000)*

66

68

35 (500)

65

61

70 (1000)

67

64

140 (2000)

68

67

210 (3000)*

68

69

35 (500)

68

60

70 (1000)

69

65

140 (2000)

69

68

210 (3000)*

1800

65

70 (1000)

1500

61

63

35 (500)
1200

61

140 (2000)
210 (3000)*

1000

71

70

* PVQ40 at 210 bar (3000 psi) and PVQ45 at 186 bar (2700 psi)
**Sound pressure data equivalent to NFPA Standard.

Temperature: 50C (120F)


Test Fluid:
URSA-ED (10W)
Inlet Pressure: Atmospheric (0 psig)

Response Data
Yoke response recorded at rated speed and pressure, 0 psi inlet, 82C (180F), SAE 10W oil. Pressure rise was 6900 bar
(100,000 psi) per second.
Control Type

On stroke

Off stroke

Pressure compensator

0.050 sec.

0.020 sec.

Load sense compensator

0.040 sec.

0.010 sec.

43

Side Ports, C & CM Controls, No. 2 Shaft


Installation dimensions in mm (inches)
Drain port D1 .875-14 UNF-2B thd. SAE
O-ring boss connection .625 O.D. tubing

Outlet port B see note.


1.3125-12 UN-2B thd. SAE
O-ring boss connection
1.000 O.D. tubing. Shown
for R.H. rotation.
Construction plug.
Do not remove.

191,00
(7.52)
41,56
(1.64)

95,25
(3.75)
50,04
(1.97)

97,28
(3.83)
194,56
(7.66)

25,37 (0.999)
25,35 (0.998)

34,04
(1.34)
20,32 (0.80)R

6,35 (0.250)
x 31.75 (1.250) Lg. key
6,38 (0.251)
58,67
(2.31)

120,65
(4.75)

28,22
(1.111)
27,97
(1.101)

Note: Ports are reversed


for L.H. rotation.

25,4
(1.00)
25,45
Max.
(1.12)
Caution While pump is operating
do not back compensator
adjustment screw out
beyond dimension shown.
Plug shown for industrial
models.

14,22
(0.56)
176,28
(6.94)
Inlet port A see note.
1.87512 UN2B thd. SAE
O-ring boss connection
1.500 O.D. tubing. Shown
for R.H. rotation
R.H.
Rotation

190,5
(7.50)

Compensator position
for L.H. rotation

Compensator position
for R.H. rotation
173,74
(6.84)

211,07
(8.31)
9,53
(.375)

118,11
(4.65)
86,87
(3.42)

28,45

(1.12)

56,90 (2.24)

101,6
(4.00)
101,5
(3.998)

73,03
(2.875)
146,05
(5.750)
Date of assembly
stamped on flange

44

93,2
(3.67)
55,63
(2.19)

63,5
(2.50)
95,76
(3.77)

12,7 (0.50)
Typ.
14,15
(0.557)
14,53
(0.572)

63,5
(2.50)

84,84
(3.34)

50,8
(2.00)

91,44
(3.60)

184,91
(7.28)

98,30
(3.87)
218,19
(8.59)

196,60
(7.74)
Alternate drain port D2
.875-14 UNF-2B thd. SAE
O-ring boss connection
.625 O.D. tubing

52,83
(2.08)

Rear Ports

173,74
(6.84)

Inlet port A see note.


1.875-12 UN-2B thd. SAE
O-ring boss connection
1.500 O.D. tubing. Shown
for R.H. rotation

Note: Ports are reversed


for L.H. rotation.

86,87
(3.42)
47,7
(1.88)

47,7
(1.88)

91,4 96,8
(3.60) (3.81)

84,8
(3.34)

73,7
84,8 (2.90)
(3.34)

3
(0.12)

Outlet port B see note.


1.3125-12 UN-2B thd. SAE
O-ring boss connection
1.000 O.D. tubing. Shown
for R.H. rotation

Alternate drain port D2


.875-14 UNF-2B thd. SAE
O-ring boss connection
.625 O.D. tubing

221,2
(8.71)

No. 1 Shaft

3,8
(0.15) 91,4
(3.60)

No. 3 Shaft
44,45
(1.75)

No. 4 Shaft
45,97
(1.81)

44,45
(1.75)

25.12
22,225
(0.989) (0.8750)
24,87
22,200
(0.979) (0.8740)

6,375
(0.251) 31,75
x
lg. key
6,350 (1.250)
(0.250)

38,1
(1.50)

33.3
(1.31)
101,6 (4.00)

101,5 (3.99)

23,75
(0.935)

30_
1.5
x 45_
(0.06)

1,52
x 45_
(0.06)
9,52
(0.375)

33,32
(1.312)

9,4
(0.37)

Spline: SAE B Involute, 13T,


16/32 DP flat root side fit

Spline: SAE B-B Involute,


15T, 16/32 DP flat root side fit

5,8
(0.23)

N Shaft with MB Flange


(Flange and shaft end ISO 3019/2-100A2HW-E25N)
10,50
(4.30)
100 (3.937)

99,95 (3.935)

42,0
(1.65)

Sq. key
8,00 (0.315)
7,96 (0.314)

28,01 (1.103)
27,71 (1.091)

11,27
(0.444)

25,006 (0.9845)

24,994 (0.9840)

9,25
(0.364)

70
(2.75)
140,0
(5.51)

45

C**V** Pressure Compensator


with Load Sensing

Load sensing comp. control


port location for R.H. rotation
.4375-20 UNF-2B thd. SAE
O-ring boss connection .250
O.D. tubing

215,90
(8.50)
239,27
(9.42)

63,5
(0.250)

28,45
(1.12)

211,32
(8.32)

22,35
(0.88)

6,60
(2.6)

131,57
(5.18)

19,05
(0.75)

CG Remote Control

Load sensing control


port location for L.H.
rotation

50,8
(2.00)
10,92
(0.43)

74,68
(2.94)

118,88
(4.68)
79,25
(3.12)

Comp. control
port for L.H.
rotation

28,45
(1.12)
Max.
55,63
(2.19)

55,63
(2.19)
Compensator adj. knob.
Do not back out adj. knob
beyond 28,45 (1.12)
dimension shown while
pump is operating.

Comp. control port location for


R.H. rotation .4375-20
UNF-2B thd. SAE O-ring boss
connection .250 O.D. tubing

46

Pressure Compensator
Control with
Adjustable Maximum
Displacement Stop D
Adjustment
Loosen locknut on adjusting rod. Turn
adjusting rod clockwise (CW) to
decrease maximum pump delivery or
counter-clockwise (CCW) to increase
maximum pump delivery until desired
setting is obtained. Secure this setting
by tightening locknut. To assist initial
priming, manual adjustment control
setting must be at least 40% of
maximum flow position.

219,4
(8.64)
279,1
(10.99)

This control enables the maximum pump


delivery to be externally adjusted from
25% to 100% while maintaining all of the
standard features of a pressure
compensated pump.
Note:
Not available with thru-drive models.

Maximum stop
adjusting screw
.250-20 UNC thd.
(Approx. cc/rev
change per turn:
PVQ40 3.22
PVQ45 3.55)

13,9
(0.59)

59,7
(2.35)
Minimum delivery position
(screw flush with nut)

Maximum delivery position

34
(1.34)

23,87
across flats
(0.94)

Compensator adj. knob.


Do not back adj. knob
beyond 28,4 (1.12)
dimension shown while
pump is operating.

97,2
(3.83)

28,4
(1.12)

127,7
(5.03)

28,4
(1.12)
Max.

55,6
(2.19)

Locknut 11,7 (0.44)


across flats

47

Electric Dual Range


Pressure Compensator with
Maximum Displacement
Stop CD**D
This control has the combined features
and adjustments of the CD control and
D control option. See preceding page
and following page for adjustment
procedures.

279,1
(10.99)

Solenoid Data
(110V AC 50 Hz and 115/120V AC 60 Hz)

Solenoid current
115/120V AC 60 Hz
110V AC 50 Hz

2 lead wires from


solenoid, approx. 152 mm
(6.00 in) long with M3 (#6)
size terminals provided for
customer connection.

219,4
(8.64)

Control position shown


for L.H. rotation

Inrush
amps
(R.M.S.)

Holding
amps
.54
.64*

2.0

15
(0.59)

* Maximum peak inrush amps approximately


1.4 x R.M.S. value shown.

Refer to catalog GB-C-2015B for


additional solenoid valve data.

Min. delivery
position (screw
flush with nut)
Control position
shown for R.H.
rotation

Note: Any sliding spool valve, if held

shifted under pressure for long periods


of time, may stick and not spring return
due to fluid residue formation and,
therefore, should be cycled periodically
to prevent this from happening.

1. Adjusting spool sets


second stage pressure

131,8
(5.19)

34
(1.34)

Max.
delivery
position

180,6
(7.11)
Max. stop adj. screw
(.250-20 UNC thd.)
73,41
(2.89)

17,53
(0.69)

Electrical conduit
connection
NPT thread

1/
2

Manual
actuator

Locknut
11,2 (0.44)
across flats

195,1
(7.68)
150,4
(5.92)

2. Locknut 17,3 (0.68)


across flats
3. Locknut must be
contained within slot of
adjusting screw as shown
4. Adjusting screw 25,4
(1.00) across flats sets
first stage pressure

5. Locknut 31,7 (1.25)


across flats

48

55,6
(2.19)

218,9
(8.62)

Electric Dual Range


Pressure Compensator
Control CD**
Adjustment
1. With the directional valve
de-energized, loosen locknut 5 and
turn the adjusting screw 4 to the
desired first stage pressure setting,
then tighten locknut 5.
2. With solenoid de-energized, turn
adjusting spool 1 counterclockwise
(CCW) until nut 3 is bottomed in
adjusting screw slot. (Second stage
setting is now equal to first stage
pressure setting.) Turn adjusting
spool clockwise (CW) to desired
second stage pressure
requirements. One complete turn of
adjusting spool equals approximately
41 bar (600 psi). Energize solenoid
and check pressure setting.
De-energize solenoid and re-adjust if
necessary. Secure this setting by
tightening locknut 2.

214,6
(8.45)
268
(10.55)
312,7
(12.31)

1. Adjusting spool sets


second stage pressure

335,2
(13.2)

2. Locknut 17,3 (0.68)


across flats

Manual
actuator

3. Locknut must be
contained within slot of
adjusting screw as shown

Electrical conduit
connection
NPT thread

4. Adjusting screw 25,4


(1.00) across flats sets
first stage pressure

1/
2

5. Locknut 31,7 (1.25)


across flats

122,2
(4.81)

Solenoid Data
(110V AC 50 Hz and 115/120V AC 60 Hz)
Solenoid current
115/120V AC 60 Hz
110V AC 50 Hz

Inrush
amps
(R.M.S.)
2.0

* Maximum peak inrush amps approximately


1.4 x R.M.S. value shown.

Refer to catalog GB-C-2015B for


additional solenoid valve data.

Holding
amps
.54
.64*

Control position
shown for R.H.
rotation

83
(3.27)

190,2
(7.49)

55,6
(2.19)
Control position
shown for L.H.
rotation

2 lead wires from


solenoid, approx. 152 mm
(6.00 in) long with M3 (#6)
size terminals provided for
customer connection.

Note: Any sliding spool valve, if held

shifted under pressure for long periods


of time, may stick and not spring return
due to fluid residue formation and,
therefore, should be cycled periodically
to prevent this from happening.
49

Unloading Valve Control UV


With the unloading valve control the
variable pump will unload at a preset
pressure. The pump will maintain this no
flow, low pressure (approximately 14 bar
[200 psi]) standby condition, until
system pressure drops to about 85% of
the preset unloading pressure. The
pump will then return on stroke and
provide full flow until the preset
unloading pressure is reached again.

Unload valve
control port
To load

Inlet

With this control, an efficient


accumulator charging circuit is obtained.
The pump will provide full flow to fill the
accumulator until the maximum
charging pressure is reached. The
pump then goes to a standby condition
until the accumulator pressure drops to
85% of the desired maximum. The
accumulator is then recharged as the
cycle starts over again.

Check Valve

Outlet
Drain

Setting Pressures
A separate right angle check valve must
be provided to maintain the accumulator
hydraulic charge and prevent back flow
when the pump is unloaded. The check
valves internal leakage must not
exceed five drops per minute. The
control port must be connected to
system pressure, downstream of the
check valve.

1. Back out accumulator unloading


pressure adjustment screw to below
desired unloading pressure.
2. Adjust desired standby pressure.

Adjustment range
PVQ40 100210 bar (15003000 psi)
PVQ45 100186 bar (15002700 psi)

3. Set accumulator pressure by


screwing in the accumulator
unloading adjustment screw.
Accumulator recharge (cut-in)
pressure is a function of the
maximum accumulator pressure
and is not adjustable.

Cut-in pressure is 85% of unloading


pressure, minimum.

4. Check pressure settings and


re-adjust if necessary.
Standby pressure
adjustment
Control Port .4375-20
UNF-2B thd. SAE O-ring boss
connection .25 OD tubing

Accumulator unloading
pressure adjustment
219,4
(8.64)

145,5
(5.95)

184.9
(7.28)

74,7
(2.94)

91.4
(3.60)

50

55,6
(2.19)

A9 & A11 SAE A Thru-Drives


28,22
(1.11)
27,97
(1.10)

97,28
(3.83)

6,35 (0.251)
Sq. key
6,30 (0.250)

25,37
(0.999)
25,35
(0.998)

147,57
(5.81)

A (see table on next page)

Output spline see


thru-drive table on next
page

31,75
(1.25)
25,4
(1.00)

194,56
(7.66)

87,38
82,55

(3.44)
(3.253)

No. 2 shaft
50.8
(2.00)

58,67
(2.31)

151,13
(5.95)
191,26
(7.53)

38,1
(1.50)

101,6 (4.00)

101,5 (3.99)

12,7
(0.500)

28,45
(1.12)
Max.

Do not back out comp.


adjusting knob beyond
this dimension while
pump is operating.

45,97
(1.81)

22,61
(0.89)

Drain port D1. .875-14 UNF-2B thd.


SAE O-ring boss connection .825
O.D. tubing

1,42 (0.056)
1,32 (0.052)
12,7
(0.50)
50,8
(2.00)

Load sensing control port


.4375-20 UNF-2B thd. SAE
O-ring boss connection .250
O.D. tubing

Note: Ports are reversed


for L.H. rotation.

Inlet port A. See note


1.50 diameter inlet. SAE
J518 4-bolt flange.
Standard pressure series
.500-13 UNC-2B thd.
1.06 deep 4 places

84,84
(3.34)

.375-16 UNC-2B thd.


.88 deep 4 places
Outlet port B.
See note. 1.00
diameter inlet.
SAE J518 4-bolt
flange. Standard
pressure series

95,25
(3.75)

26,18
(1.031)

.375-16 UNC-2B
thd. .72 deep
2 holes
84,84
(3.34)

23,75
(0.935)

52,37
(2.062)

Outlet port B face

69,85
(2.75)
73,6
(2.90)

1,52 (0.06) x 45_


34,935
(1.375)
9,4
(0.37)

14,48
(0.57)
35,7
(1.406)
242,06
(9.53)

91,44
(3.60)

95,76
(3.77)

13,1
(0.516)
26,2
(1.031)

17,86
(0.703)
A flange
Alternate drain
port D2

53,09
(2.09)
91,95
(3.62)

105,43
(4.19)
91,95
(3.62)

51

B26 SAE B Thru-Drive


142,4
(5.61)

41,6
(1.64)

Outlet port B see note.


1.3125-12 UN-2B thd SAE O-ring
boss connection 1.00 O.D. tubing

191,0
(7.52)

A (see below)

5,8
(0.23)
98,5
No. 4 shaft
(3.88)
Modified
involute spline
SAE BB
197,3
(7.77)
1,52
(0.06)
x 45_

107,2 (4.221)
107,1 (4.219)

23,75
(0.935)
38,10
(1.500)

1,45 (0.057)
1.30 (0.051)

Drain port
176,3
(6.94)

45,9
(1.81)

Do not back out comp. adjusting knob


beyond this dimension while pump is
operating.

12,7
(0.50)

57,2
(2.25)

Note: Ports are reversed


for L.H. rotation.

28,45
(1.12)
Max.

Load sensing control port


.4375-20 UNF-2B thd. SAE
O-ring boss connection
.250 O.D. tubing

9,7
(0.38)
14,5
(0.57)

No. 2 shaft
6,35
31,75
x
lg. key
(0.25) (1.250)

101,7 (4.003)
101,6 (4.001)

25,4
(1.00)

120,65
(4.75)

.500-13
UNC-2B thd
.88 deep
2 holes

Inlet port A see note. 1.875-12


UN-2B thd. SAE O-ring boss
connection 1.500 O.D. tubing

28,2 (1.110)
27,9 (1.100)
101,6

(4.00)
63,50
(2.50)

25,1

(0.999)
50,8
(2.00)
56,7
(2.31)

73,03
(2.875)

254,8
(10.03)

146,05
(5.750)
95,25
(3.75)

95,25
(3.75)
98,30
(3.87)
196,6
(7.74)

Max. Torque
Nm (in. lb.)

Dimension A
mm (in)

Coupling Type

Thru-drive
Coupling

ASA B5.15-1960
9 teeth 16/32 DP
Flat root side fit

58 (517)

10,92 (0.43)

9T/9T

864224

A11

ANS B92.1-1970
11 teeth 16/32 DP
Flat root side fit

118 (1050)

12,57 (0.495)

11T/11T

864325

24,89 (0.98)

26T/26T

627168

B26

Special Vickers
26 teeth 32/64 DP
Flat
Fl t root side fit
t id

10,92 (0.43)

26T/13T

864307

20,56 (0.81)

26T/15T

475134

Model Series

Spline Data

A9

179 (
(1587)
)

Note: Coupling, screws, and washers must be ordered separately to mount rear pump. A O-ring (AS568-042) and B O-ring (AS568-155) are
included with each thru-drive pump. Couplings for B26 are step type for 13 and 15 tooth as shown.

52

Thru-drive Shaft Torque Limits


Input Shaft Code
2

337 (2987)

215 (1900)

208 (1850)

337 (2987)

337 (2987)

215 (1900)

208 (1850)

337 (2987)

PVQ40/45B26

337 (2987)

PVQ40/45A11

208 (1850)

PVQ40/45A9

215 (1900)

Model Series

Maximum Input
Torque Total
Nm (lb. in.)

Maximum Thru-drive
Torque Output
Nm (lb. in.)

337 (2987)

58 (517)

123 (1100)

179 (1587)

Note: Both input and output limits must be met.

Typical Rear Pumps (with Shaft Codes) for


PVQ40/45 Thru-Drives
Model
Series

Rear Pump
Shaft Code

PVQ10/13

PVB5/6

S124 suffix

V10

11

V20

A9

Typical Rear Pump

Thru-drive
Coupling

62

864224

2
PVE12

864307

28

627168

864307

28

627168

864307

475134

28

627168

V2010 OR V2020

11

864307

20V

151

864307

2520V

166

475134

PVQ20/32
B26

PVQ40/45

Note: A11 (not listed above) is intended for special application only.

53

Thru-Drive Pump Support Bracket


An optional support bracket should be
used when a heavy second pump is
mounted to a thru-drive PVQ40 or
PVQ45. The support bracket (627179),
two screws (199740), and two washers
(427700) must be ordered separately.

171,45
(6.75)
11,68
(0.46)

147,83
(5.820)
10,41 (0.410)

2 holes
10,29 (0.405)

85,85
(3.38)

33,78
(1.33)
82,55
(3.25)

17,27
R
(0.68)

55,37
(2.18)

12,85 (0.506)

2 holes
12,73 (0.501)

19,05
(0.75)

19,05
(0.75)

19,05
(0.75)
28,575
(1.125)

54

114,30
(4.500)

28,575
(1.125)

85,85
(3.38)

PVQ63 Model Series

Ratings

Model Series

Maximum
Geometric
Displacement
cm3/r (in3/r)

Rated
Speed
r/min

Maximum
Pressure
bar (psi)

Input Power at
Max. Pressure &
Rated Speed
kW (hp)

Approx.
Weight
kg (lb)

PVQ63

63,0 (3.844)

1800

210 (3000)

47,5 (64)

63,0 (139)

Pressure Limits
Case pressure 0,35 bar (5 psig) maximum
Inlet pressure 0,2 bar (5 in. Hg) vacuum to 2 bar (30 psig)

Model Code

P
V
Q
2

R
L

Inline piston pump


Variable volume
Quiet series

FS Flange SAE side port

Displacement in cc/rev and pressure


ratings

Mounting flange specifications

C2 Flange SAE C 2-bolt


4

Series PVQ

63 63,0 cc/rev (3.84 cir), 210 bar


(3000 psi)
3

Rotation viewed from shaft end


Right hand (cw), standard
Left hand (ccw), optional

Ports, type and location

Shafts, input

Straight keyed SAE C, long

Seals

Buna N, standard

Pump design number

10 Design (PVQ63 with EDG controls)


20 Design (PVQ63 with C** controls)
Design number subject to change.
Installation dimensions remain
unchanged for designs 1019 and
2029.

10

Control type

C**

Pressure compensator. Standard


model is C21, indicating setting of
210 bar (3000 psi); range is 0221
in tens of bar (3503000 psi).
CG
Pressure compensator modified
for hydraulic remote control.
CGV6F Remote pressure compensator
with high response load sensing
control. Load sensing setting is
6 bar (87 psi) P, without
bleed-down orifice.
EDG
Direct electric displacement control
with remote pressure compensator.
10

Control design

10 CG, CGV6F, and EDG


11 C**

55

Pressure Compensator
Control C

LS

The pressure compensator control


automatically adjusts pump delivery to
maintain volume requirements of the
system at a preselected operating
pressure. Maximum pump delivery is
maintained to approximately 3,4 bar (50
psi) below the pressure control before
being reduced. The pressure
compensator control operates on one
side of center and has an adjustment
range as designated in the model
coding.

P
R

Dr

Dr
CG

Load Sensing & Remote


Compensator Control CGV6F

Dr

Remote Control Pressure


Compensator CG
This compensator is the same as the
C compensator, except the machine
operator is able to change the
compensator setting through the use of
a remote pilot relief valve. The pump
must not be operated with the remote
compensator port plugged; the port
must be connected to a remote pilot
relief valve, such as Vickers C-175. The
effective compensator setting is the sum
of the compensator control setting and
the remote relief valve setting.

56

This control provides load sensing


control under all pressure conditions up
to the desired maximum pressure
controlled by a remote relief valve. It
automatically adjusts pump flow in
response to a load pressure signal and
maintains outlet pressure at a level
approximately 6 bar (87 psi) above load
pressure. By venting the load sense line
with external valving when no flow or
pressure demands are placed on the
system, the pump will go to a no-flow,
low pressure, energy conserving
standby mode. A remote pressure relief
valve is required to override the load
sensing control, reducing pump
displacement as the preset maximum
operating pressure is reached.

CGV6F
The pumps outlet flow is used to stroke
the pump. An integral sequence valve
maintains a minimum outlet pressure of
10 bar (150 psi) to assure the necessary
control pressure is available. Controller
EDQ-L-30 is needed to drive the
proportional valve and provides the
appropriate interface for the LVDT.

Direct Electric Displacement


Control with Remote Pressure
Compensator EDG
This control varies pump flow from zero
to maximum displacement in response
to an input voltage of 05 volts. The
pump has an integral LVDT feedback
device that measures yoke position. The
electric control is overridden by a
remote pressure compensator. When
the system pressure reaches the remote
compensator relief valve setting, the
pump is destroked to the displacement
needed to maintain the selected
pressure.

POS

EDG

Performance at 1800 r/min


100%
Efficiency

Volumetric efficiency
Overall efficiency

80%
60%

Delivery l/min (USgpm)

Input power

40 (53.6)

Delivery
120 (31.7)

30 (40.2)

80 (21.1)

20 (26.8)

40 (10.5)

Input power pump compensated


0

70
(1000)

140
(2000)

Input power Kw (hp)

50 (67.0)

40%

10 (13.4)
210
(3000)

Outlet pressure bar (psi)

Sound Data
Speed
r/min

Sound Level dB(A)*

Pressure
Press re
bar (psi)

Full Stroke

Cutoff

35 (500)

53

45

70 (1000)

59

58

56

46

58

56

140 (2000)

60

53

210 (3000)

62

59

35 (500)

59

50

70 (1000)

60

53

140 (2000)

63

60

210 (3000)

65

64

35 (500)

63

56

70 (1000)

65

60

140 (2000)

69

67

210 (3000)

1800

54

70 (1000)

1500

48

56

35 (500)
1200

54

140 (2000)
210 (3000)

1000

70

68

*Sound pressure data equivalent to NFPA Standard.

Temperature: 50C (120F)


Test Fluid:
URSA-ED (10W)
Inlet Pressure: Atmospheric (0 psig)

57

Response Data
Yoke response recorded at rated speed and pressure, 0 psi inlet, 82C (180F), SAE 10W oil. Pressure rise was 6900 bar
(100,000 psi) per second.
Control Type

On stroke

Off stroke

Pressure compensator

0.108 sec.

0.031 sec.

Load sense compensator

0.075 sec.

0.025 sec.

C Control
Installation dimensions in mm (inches)
35,7
(1.40)
17,85
(0.70)

Outlet
30

port P (1.18)

M12

23
deep
(0.90)

69,8
(2.75)

34,9
(1.37)

Case drain port Dr.


1 1/16-12 UN

128
(5.04)

256
(10.08)

7,95 (0.3129)
Sq. Key
7,935 (0.3124)
78
(3.07)

+0
0,05
+0
(5.00)
0.002
127

295
(11.61)

R16
(R0.63)
60
(2.36)
9,5
(0.37)
57,2
(2.25)

14,5
(0.57)

260,5
(10.25)

Adj. screw

163,4
147 (6.43)
(5.79)
34,9
(1.37)

130
(5.12)

90,5
(3.56)

57,2
(2.25)

58

84
(3.31)

139,3
(5.48)
153,6
(6.05)

97,5
(3.84)

35,2 0,1
(1.385 0.004)
+0
31,75
0,05
+0
(1.25)
0.002

114
(4.50)
181
(7.12)

30
(1.18)
Max.

69,8
(2.75)

114,4
(4.50)

17,5
6
(0.69)

24
hex
(0.94)

35,7
(1.40)
252
(9.92)

Inlet
38

port I (1.50)
23
deep
M12
(0.90)
17,85
(0.70)

107
(4.21)

107
(4.21)

CGV6F Control
2,4
(0.09)

120
(4.72)
71
(2.79)

8
(0.31)
Max.

68
(2.68)

30
(1.18)

36,5
(1.44)

Unadjustable
60
(2.36)

Remote compensator port R


7/ - 20 UNF
16

36,5
(1.44)

14,5
(0.57)
9,5
(0.37)

194
(7.64)

Load sensing port LS


7/ -20 UNF
16
57,2
(2.25)

142
(5.59)

130
(5.12)

34,9
(1.37)

7,95 (0.3129)
Sq. Key
7,935 (0.3124)

177
(6.97)

114,4
(4.50)
35,2 0,1
(1.385 0.004)

90,5
(3.56)
181
(7.12)

17,5
6
(0.69)
57,2
(2.25)

69,8
(2.75)

+0
0,05
+0
(1.250)
0.002
31,75

Inlet
38

port I (1.50)

23
M12
deep
(0.90)

114,4
(4.50)

252
(9.92)

17,85
(0.70)
35,7
(1.40)

CG Control
128
(5.04)

256
(10.08)

Remote control port R


7/ -20 UNF
16

114,2
(4.50)
84,6
(3.33)

127+0
0,05
(5.00)
+0
0.002

8
(0.31)
Max.
39,5
(1.55)
Unadjustable

7,95 (0.3129)
Sq. Key
7,935 (0.3124)

60
(2.36)
9,5
(0.37)

78
(3.07)

Case drain port Dr.


11/16-12 UN
296
(11.65)

14,5
(0.57)

260
(10.25)

41
(1.61)

140
34,9 (5.51)
(1.37)

130
(5.12)
57,2
(2.25)

69,8
(2.75)

114,4
(4.50)
35,2 0,1
(1.385 0.004)
17,5
6
(0.69)
57,2
(2.25)
114,4
(4.50)
181
(7.12)

90,5
(3.56)

+0
0,05
+0
(1.250)
0.002

Inlet
38

port I (1.50)

31,75

23
deep
M12
(0.90)

252
(9.92)

17,85
(0.70)
35,7
(1.40)

59

EDG Control
Case drain port Dr.
11/16-12UN
+0
0,05
+0
(5.00)
0.002
127

Remote control port R


7/ -20 UNF
16

128
(5.04)
256
(10.08)

7,95 (0.3129)
Sq. Key
7,935 (0.3124)
Filling port

78
(3.07)

296
(11.65)

318
(12.52)
237,5 (9.35) Max.

Connector JIS C 5432


CNR01SPF 013 005

67
(2.64)

60
(2.36)

Outlet port P
11/16-12UN
57,2
(2.25)

8,5
(0.33)
Max.

14,5
(0.57)

Outlet port P1
11/16-12UN

9,5
(0.37)
241
(9.49)
34,9
69,8
(1.37) (2.75)

31,8
(1.25)
130
(5.12)

194
(7.64)

114,4
(4.50)

17,5
6
(0.69)
57,2
(2.25)

114,4
(4.50)
90,5
(3.56)
181
(7.12)
158
(6.22)

60

+0
0,05
+0
(1.250)
0.002

100,5
(3.96)
Inlet
38

port I (1.50)

31,75

35,2 0,1
(1.385 0.004)

23
M12
deep
(0.90)
35,7
(1.40)
252
(9.92)

17,85
(0.70)

107
(4.21)

107
(4.21)
158
(6.22)
209,5
(8.25)

EDQ-L-30 Amplifier/Controller
Schematic Block Diagram

200 mA (Q in <50 MV)

Jump

Mode
SW1

Qc
CP1**

Qe
CP2

X1
Q in
Q in

X0.5
Mode switch (SW1)
=1, Input demand 0-5V
=2, Input demand 0-10V

3
9V

VR3

V/I
CP4

0:1.27
1:1.46
2:1.63
3:1.82
4:2.00*
5:2.19
6:2.36
7:2.55

Gain
SW2

lm
CP7

PWM

SOL

+9V
Note: Limit time of mode switch at
4 to less than 15 minutes

VR9
Bias
P in

P in

0~1.0
Compensating value for internal
pump leakage proportional to
system pressure (optional).

VR11
DG

Qm
CP6

X0.2

VR13
DF

LV
CP5

50Hz
X1.0

CP8**
Ev

LVDT I/F

JP1
X1.2
60Hz

LVDT
(Installed in pump and
senses yoke position)

(JP1 switch selects frequency


set to 50Hz at factory)

* Factory setting

**CP1 and CP8 are observed as negative voltage.

VR5
Offset

VR6
Span

61

General Ratings
Item

Minimum

Typical

Maximum

Units

Vp=+24V

1.2

Idd

Vdd=+15V

80

mA

Iss

Vss=15V

60

mA

Mode SW=1

Mode SW=2

Dem nd Inp t
Demand Input

Condition

Ip
Power Current

Symbol

10

Qin

Jump Threshold

Qj

46

50

54

mV

Jump Value

Ij

Qin < Qj

220

200

180

mA

VR13=CCW

80

90

100

Delivery Adj.

115

120

125

VR13=CW

200

230

260

VR11=CCW

Delivery Adj.

280

300

VR11=CW

280

300

320

Bias=CCW

0.67

0.70

0.74

Delivery Adj.

0.95

1.00

1.05

Bias=CW

1.10

1.15

1.20

Io=1.0A

0.98

1.00

1.06

Gain=0

1.24

1.27

1.30

Gain=1

1.43

1.46

1.49

Gain=2

1.60

1.63

1.66

Gain=3

1.78

1.82

1.86

Gain=4

1.96

2.00

1.04

Gain=5

2.15

2.19

2.23

Gain=6

2.31

2.36

2.41

Gain=7

2.50

2.55

2.60

Dither Frequency

Dither Amplitude

Bias Current

Current Monitor

Proportion l Gain
Proportional G in

62

DF

DG

Bias

Im

Kp

Hz

mA

Installation Dimensions
Millimeters (inches)

OFF
SET
SPAN

180
(7.09)

CN3

170
(6.69)

CP9

VR5
CP5

(descriptions,
see next page)
1: PR1+
2: PR1
3: SEC+
4: SEC
5: SG

50Hz
60Hz

CP7

VR6

CP6
CP4

CP8

43
(1.69)

1
JP1
3

VR3

1: Qm
2: Qin+
3: Qin
4: Pin+
5: Pin
6: SG

150
(5.90)
CN2

CP3

GAIN

SW2
75
(2.95)

MODE
OC
SPAN
BIAS

CP1

CP2

SW1
VR9
CP10

VR11
5
(0.20)

53
(2.08)

VR13

20
(0.79)

9
(0.35)

96.5
(3.80)

40
(1.57)

(descriptions,
see next page)
1: Vss

Check Pins
CP1 (red):

Qc; value of demand after Mode switch (negative)

2: SG

CP2 (green):

Qe; difference between Qc and Qm

3: Vdd

CP3 (black):

SG; signal ground

4: Vp

CP4 (brown):

V/I; final control value

5: 0Vp

CP5 (blue):

LV; rectified secondary signal of LVDT

6: SOL+

CP6 (yellow):

Qm; yoke position (0 to 5V)

7: SOL

CP7 (white):

Im; voltage converted form output current (1A/1V)

CP8 (orange):

Ev; compensating value for internal leakage (negative)

CP9 (purple):

Losc; oscillation signal for LVDT (sine wave, 4 to 4.4 kHz)

CP10 (white):

Dosc; oscillation signal for dither (square wave, 120 Hz)

CN1

63

Connector Pin Assignment Descriptions


(from previous page)

Pin CN1
Pin Number

Symbol

Description

Vss

Power for signal process (15V)

SG

Return line of Vss and Vdd (signal ground)

Vdd

Power for signal process (+15V)

Vp

Power to drive solenoid coil (+24V)

0Vp

Return line of Vp (connected SG on the boad)

SOL+

Output to solenoid coil (+ side)

SOL*

Output to solenoid coil ( side)

* SOL is isolated from SG.

Pin CN2
Pin Number

Symbol

Description

Qm

Yoke position monitor (connected to CP6 on the boad)

Qin+

Demand input (+ side)

Qin*

Demand input ( side)

Pin+

Pressure signal input (+ side)

Pin

Pressure signal input ( side)

SG

Signal ground (connected to CP3 on the boad)

* Qin and Pin are isolated from SG.

Pin CN3
Pin Number

Symbol

Description

PRI+

Output to primary coil of LVDT (+ side)

PRI*

Output to primary coil of LVDT ( side)

SEC+

Input from secondary coil of LVDT (+ side)

SEC*

Input from secondary coil of LVDT ( side)

SG

Signal ground (connected to CP3 on the boad)

* PRI and SEC are isolated from SG.

Amplifier/Controller to LVDT Connection

2
4

Pump Side (LVDT)


64

Controller Side (CN3)

Application Data

Fluid Cleanliness
Proper fluid condition is essential for
long and satisfactory life of hydraulic
components and systems. Hydraulic
fluid must have the correct balance of
cleanliness, materials, and additives for
protection against wear of components,
elevated viscosity, and inclusion of air.
Essential information on the correct
methods for treating hydraulic fluid is
included in Vickers publication 561
Vickers Guide to Systemic
Contamination Control available from
your local Vickers distributor or by

contacting Vickers, Incorporated.


Recommendations on filtration and the
selection of products to control fluid
condition are included in 561.
Recommended cleanliness levels, using
petroleum oil under common conditions,
are based on the highest fluid pressure
levels in the system and are coded in
the chart below. Fluids other than
petroleum, severe service cycles, or
temperature extremes are cause for
adjustment of these cleanliness codes.
See Vickers publication 561 for exact
details.

Vickers products, as any components,


will operate with apparent satisfaction in
fluids with higher cleanliness codes than
those described. Other manufacturers
will often recommend levels above
those specified. Experience has shown,
however, that life of any hydraulic
component is shortened in fluids with
higher cleanliness codes than those
listed below. These codes have been
proven to provide a long, trouble-free
service life for the products shown,
regardless of the manufacturer.

System Pressure Level


bar (psi)
Product

<70 (<1000)

70-210 (1000-3000)

210+ (3000+)

Vane Pumps Fixed

20/18/15

19/17/14

18/16/13

Vane Pumps Variable

18/16/14

17/15/13

Piston Pumps Fixed

19/17/15

18/16/14

17/15/13

Piston Pumps Variable

18/16/14

17/15/13

16/14/12

Directional Valves

20/18/15

20/18/15

19/17/14

Pressure/Flow Control Valves

19/17/14

19/17/14

19/17/14

CMX Valves

18/16/14

18/16/14

17/15/13

Servo Valves

16/14/11

16/14/11

15/13/10

Proportional Valves

17/15/12

17/15/12

15/13/11

Cylinders

20/18/15

20/18/15

20/18/15

Vane Motors

20/18/15

19/17/14

18/16/13

Axial Piston Motors

19/17/14

18/16/13

17/15/12

Radial Piston Motors

20/18/14

19/17/13

18/16/13

65

Hydraulic Fluids and


Temperature Ranges
Use antiwear hydraulic oil, or
automotive type crankcase oil
designations SC, SD, SE or SF per SAE
J183FEB80.
Select a viscosity grade that will allow
optimum viscosity, between 40 cSt (180
SUS) and 16 cSt (80 SUS), to be
achieved within the optimum
performance envelope shown below.
For further information, see Vickers data
sheet B-920 or I-286-S.

Fire Resistant Fluids


All pumps can be used with water glycol
and polyol ester fluids. All except

PVQ16 and PVQ63 can be used with


phosphate ester fluids. All pumps can
be operated to 140 bar (2000 psi) with
these fluids, except PVQ13 and PVQ32
which are limited to 105 bar (1500 psi).
Input speed should not exceed 1800
r/min. System temperature should not
exceed 54 C (130 F). Inlet vacuum
should not exceed 101,6 millibar (3 in.
Hg). For more information, refer to
Vickers publication 579.

Installation and Start-up


(Commissioning)
Before a pump is started, fill the case
through the uppermost drain port with
hydraulic oil of the type to be used. The
case drain line must be connected to the
reservoir below oil level.

For multiple pump arrangements that


include non-PVQ sections, the
requirements of the non-PVQ units must
be considered.

Ordering Procedure
Order pumps by the full model
designation. Pump displacement,
mounting flange type, direction of
rotation, pump configuration, shaft end
type, seals, pressure adjustment range,
and specific control functions are all
specified in the full model code.
Couplings, O-rings, capscrews and
washers must be ordered separately for
all thru-drive pumps.

Viscosity
SUS
2300

cSt
500
Extreme performance envelope
Typical SAE 10W
viscosity grade oil

54

70

13

250

Optimum performance
envelope

20

10

50

_C

38

82

100
Temperature

65

150

180 _F

You might also like