Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Petrogas Filtration Catalogue

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12
At a glance
Powered by AI
The key takeaways are that Petrogas designs and manufactures filtration products like dust filters and coalescer cartridges to remove particles from gases. They aim to protect downstream equipment and reduce maintenance costs.

Petrogas' main products are dust filter and coalescer cartridges. They are designed for applications in filter-separators to remove particulates from air, hydrogen, and natural gas streams. Petrogas also provides turn-key gas installations.

Petrogas upholds a stringent quality control policy and uses high quality materials from a global leader in filtration media. Their manufacturing is ISO9001 certified to ensure consistent high quality. They also continuously conduct research and testing to improve their products.

where nature and technology meet

PETROGAS GAS-SYSTEMS BV
www.petrogas.nl
Solutions for filtration applications
F I L T R A T I O N
F I L T R A T I O N
An introduction
Baffle plate coalescer seperator skid - designed
and manufactured by Petrogas Gas-Systems BV
Petrogas upholds a stringent QC policy ensuring that every filter cartridge
delivers a performance according to its design. Besides rigorously upholding
our quality we are also constantly trying to improve upon it. Through
research, desi gn and f requent testi ng we are constantly sti mulati ng
product development and improvement.
Clean and aerosol free gas is critical for industrial equipment
to operate effectively and reliably. Petrogas filtration is dedicated
to designing and manufacturing dust filter and coalescer cartridges
that provide high efficiency removal of solids and liquids from
contaminated gases, ultimately protecting downstream equipment
and reducing maintenance costs.
Petrogas f i ltrati on i s a part of
Petrogas Gas-Systems, which is a
renowned Du tc h engi neeri ng
c om pany t hat d evel ops ,
manufactures and supplies turn-
key gas installations worldwide.
Our f i lter cartri dges are hence
mainly designed for application
i n f i lter-seperators to remove
parti c u lates f rom the proc ess
stream s of ai r, hy d rogen and
natural gas.
Petrogas Filter Separator
Petrogas Dust Filter
Curing heat equipment after pleating phase Blade type pleating equipment to bond multi layered media
We use only high quality grade media materials from a prominent supplier
that is a global leader in creating, manufacturing and supplying technically
advanced high efficiency and liquid filtration media.
Our manufacturing is ISO9001 certified and is carried out to the highest
standards using the latest manufacturing technology to ensure a high
quality, consistent product.
High grade engineered
media materials
F I L T R A T I O N
Filter Element Performance Testing Method
Petrogas filtration has conducted elaborate filtration efficiency tests at renowned testing facilities.The
test method and apparatus are in accordance with VDI 3926 standard.
The performance test for separation of solid particles is operated by negative pressure suction in such a
way that a fixed quantity of test dust particles are added constantly through the feeder (Palas BEG-1000)
at air intake. The aerosol enters into the filter and passes through the filter element to achieve filtering.
The solid particles are discharged finally through the ash hopper. A number of sensors are used in the test
to check the actual working performance of the filter element at different filtration velocities. The test
procedure is as shown in Fig. 1. Relevant parameters measured in the test are as below:
The performance test for separation of liquid particles is also operated
by negative pressure suction in such a way that a fixed quantity of gas-
liquid mixture is added constantly through the sprayer at filter inlet. The
aerosol enters into the filter and passes through the coalescence filter
element to achieve filtering. The liquid is discharged finally through the
liquid outlet. A number of sensors are used in the test to check actual
agglomerati on worki ng performance of the fi lter element at di fferent
filtration velocities.
Dust measured: ISO COARSE A.T.D. A4 dust
gas-liquid test apparatus
Fig. 1 Overview Test Device (Gas-Solid)
Test method and laboratory apparatus are in accordance with VDI3926 standard.
Relevant parameters: Test temperature 27

C, relative humidity 44.8 %, particle diameter 0.3~17m


gas-solid test apparatus
F I L T R A T I O N
Filter Element Performance Testing Method
The test for separation of liquid particles is as shown in Fig. 2. Relevant parameters measured in the test
are as below:
Atomized liquid: dioctyl sebacate (DOS) ; Sprayer model: SU11 (Spraying Systems Co.)
Fig. 2 Overview Test Device (Gas-Liquid)
The measuring of aerosol particle size and distribution in the up-stream and
down-stream of the filter is done by an optical particle counter (Palas Welas
3000 Seri es). Thi s parti cle measuri ng system, as shown below i n Fi g. 3,
includes a vacuum pump, sampling nozzle, diluter and computed particle
detection system.
Sampling is made with the own vacuum pump in Welas

Control System and
the sampling flow is 5 Lmin
-1
. A series of sampling nozzles are fabricated
aiming at the common flow range. In order to ensure coaxial and isokinetic
sampling the diameter of the sampling nozzle change with the inlet velocity,
allowing for the particles to be equally collected regardless of their size.
Fig. 3 Particle measurement system
Welas particle measuring control unit
Test method and laboratory apparatus are in accordance with VDI3926 standard.
Relevant parameters: Test temperature 27

C, relative humidity 44.8 %, particle diameter 0.3~17m


F I L T R A T I O N
Low Temperature Dust Filter Cartridges
The P-DS LT series filter cartridge is a composite of pleated cellulose and
polyester fiber and ensures high efficient removal of dust particles in air,
hydrogen, natural gas and other industrial gases.
This filter is recommended for low temperature applications with peak
temperatu res u p to 90

C. The poly ester rei nf orc ement stabi li zes the


cellulose and provides greater moisture resistance. Its pleated structure
maximizes the effective filtration area which assures high flow rate, low
differential pressure and an ultimately longer service life. The filter has
an inner and outer metal mesh for support and protection of the filter
media.
Due to its high effective filtration area and high efficiency media, this
fi lter provi des a hi gh soli d removal effi ci ency whi ch ensures opti mum
protection of downstream equipment.
Product Specifications:
Materials of Construction
Filter Media (4): Resin impregnated high cellulose grade with 20% water repellent polyester
fibers. Inner Core (5): Q235 perforated galvanized steel
Outer Core (3): Q235 perforated galvanized steel
End Caps (1): Q235 Galvanized sheet steel
Gasket (2): Wool felt
Available Dimensions:
Inside / outside diameters [mm]:
170/230; 220/280; 270/330; 350/410
Lengths [mm]: 500, 600, 750
Additional sizes upon request.
Performance Specifications:
Filter efficiency: refer to graph
Flow direction: from outside to inside
Maximum allowable differential pressure: 1.5 bar
Recommended change cartridge differential pressure: 800-1000 mbar
Maximum operating temperature: 70

C ;
short peak temperatures of max. 90

C (max. 20 min.) are acceptable.


Test method and apparatus: according to VDI 3926 testing
standards of filtration media.
c
u
m
u
l
a
t
i
v
e

v
o
l
u
m
e
t
r
i
c

e
f
f
i
c
i
e
n
c
y

o
f

p
a
r
t
i
c
l
e
s

>
D
p
Particle Separation
Particle diameter Dp [m]
F I L T R A T I O N
Medium Temperature Dust Filter Cartridges
The P-DS MT series filter cartridge is a composite of pleated cellulose
and polyester fiber and ensures high efficient removal of dust particles
in air, hydrogen, natural gas and other industrial gases.
This filter is recommended for medium temperature applications with
peak temperatures up to 150

C . The polyester reinforcement stabilizes


the cellulose and provides greater moisture resistance. Its pleated structure
maximizes the effective filtration area which assures high flow rate, low
differential pressure and an ultimately longer service life. The filter has
an inner and outer metal mesh for support and protection of the filter
media.
Due to its high effective filtration area and high efficiency media, this
fi lter provi des a hi gh soli d removal effi ci ency whi ch ensures opti mum
protection of downstream equipment.
Product Specifications:
Materials of Construction
Filter Media (4): Resin impregnated high cellulose grade with 20% water repellent polyester
fibers. Inner Core (5): Q235 perforated galvanized steel
Outer Core (3): Q235 perforated galvanized steel
End Caps (1): Q235 Galvanized sheet steel
Gasket (2): Wool felt
Performance Specifications:
Filter efficiency: refer to graph
Flow direction: from outside to inside
Maximum allowable differential pressure: 1.5 bar
Recommended change cartridge differential pressure: 800-1000 mbar
Maximum operating temperature: 120

C ;
short peak temperatures of max. 150

C (max. 20 min.) are acceptable.


Available Dimensions:
Inside / outside diameters [mm]:
170/230; 220/280; 270/330; 350/410
Lengths [mm]: 500, 600, 750
Additional sizes upon request.
Test method and apparatus: according to VDI 3926 testing
standards of filtration media.
c
u
m
u
l
a
t
i
v
e

v
o
l
u
m
e
t
r
i
c

e
f
f
i
c
i
e
n
c
y

o
f

p
a
r
t
i
c
l
e
s

>
D
p
Particle Separation
Particle diameter Dp [m]
F I L T R A T I O N
Ultra High Temperature Dust Filter Cartridges
The P-DS UHT seri es fi lter cartri dge i s a pleated combi nati on of hi gh
temperature resistant felt on a stable support and ensures high efficient
removal of solid particles from hot moist gaseous media.
This filter is recommended for ultra high temperature applications with
peak temperatures up to 260

C. It's pleated struc ture maxi mi zes the


effecti ve fi ltrati on area whi ch assures hi gh flow rate, low di fferenti al
pressure and an ultimately longer service life. The filter has an inner and
outer metal mesh for support and protection of the filter media.
Due to its high effective filtration area and high efficiency media, this
fi lter cartri gde provi des a hi gh soli d removal effi ci ency whi ch ensures
optimum protection of downstream equipment.
Product Specifications:
Materials of Construction
Filter Media (4): high temperature resistant felt
Inner Core (5): Q235 perforated galvanized steel
Outer Core (3): Q235 perforated galvanized steel
End Caps (1): Q235 galvanized sheet steel
Gasket (2): high temperature resistant felt
Available Dimensions:
Inside / outside diameters [mm]: 170/232
Lengths [mm]: 500, 600, 750
Additional sizes upon request.
Performance Specifications:
Filter effiency: refer to graph
Flow direction: from outside to inside
Maximum allowable differential pressure: 3 bar
Recommended change cartridge differential pressure: 1000 mbar
Continuous operating temperature: 240

C
short peak temperature of max. 260

C (max .30min.) are acceptable


Test method and apparatus: according to VDI 3926 testing
standards of filtration media.
c
u
m
u
l
a
t
i
v
e

v
o
l
u
m
e
t
r
i
c

e
f
f
i
c
i
e
n
c
y

o
f

p
a
r
t
i
c
l
e
s

>
D
p
Particle Separation
F I L T R A T I O N
Liquid Separation Filter Cartridges
Product Specifications:
Materials of Construction
Prefilter Media (6): polyester
Coalescing Media (3): densely wrapped layers of glass microfibers
Inner Core (5): Q235 perforated galvanized steel
Outer Core (4): Q235 perforated galvanized steel
End Caps (1): Q235 galvanized sheet steel
Gaskets (2): wool felt
Available Dimensions:
Inside / outside diameters [mm]: 90/150
Lengths [mm]: 735, 835, 1100
Additional sizes upon request.
The P-LS LT series is a cost effective liquid coalescer filter cartridge that
removes liquid particles from wet gas with an ultra high efficiency while
simultaneously presenting a very low restriction to gas flow, resulting in
low pressure drop.
This filter is recommended for low temperature applications with peak
temperatures up to 120

C. It's composite structure of wound polyester


and densely wrapped layers of glass microfibers yields maximum efficiency.
A cotton sock f orms the most outer layer of the f i lter to absorb the
coalesced moisture.
Due to its high effective filtration area and high efficiency media, this
filter provides a low saturated pressure drop and a consistent high liquid
removal ef f i ci ency whi ch ensures opti mum protecti on of downstream
equipment.
Test method and apparatus: according to VDI 3926 testing
standards of filtration media.
c
u
m
u
l
a
t
i
v
e

v
o
l
u
m
e
t
r
i
c

e
f
f
i
c
i
e
n
c
y

o
f

p
a
r
t
i
c
l
e
s

>
D
p
Liquid Separation
Performance Specifications:
Filter effiency : refer to graph
Flow direction : inside to outside
Maximum allowable differential pressure: 2.0 bar
Recommended change cartridge differential: 800-1000 mbar
Maximum operating temperature: 70

C
short peak temperature of max. 120

C (max .20min ) are acceptable


F I L T R A T I O N
Low Temperature Coalescer Filter Cartridges
Available Dimensions:
Inside / outside diameter [mm]:
90/150; 160/240
Lengths [mm]: 600, 735, 835, 1100
Additional sizes upon request.
The P-DLS LT seri es i s a cost ef f ecti ve coalescer f i lter that removes
parti c les f rom moi st natu ral gas wi th an u ltra hi gh ef f i c i enc y whi le
simultaneously presenting a very low restriction to the gas flow, resulting
in low pressure drop.
This filter is recommended for low temperature applications with peak
temperatures up to 90

C. It's high performance is two-phased: Pre-filtering


and Coalescing.
Pre-filtering removes dirt particles using a three layered pre-filter that
is composed of resin impregnated pleated cellulose, polyester and glass
mi crof i bers. The second coalesci ng phase uti li zes a densely wrapped
fiberglass for maximum efficiency. A cotton sock forms the most outer
layer of the filter to absorb the coalesced moisture.
Due to its high effective filtration area and high efficiency media, this
filter provides a low saturated pressure drop and a consistent high solid
and li qu i d removal ef f i c i enc y whi c h ensu res opti mu m protec ti on of
downstream equipment.
Test method and apparatus: according to VDI 3926 testing
standards of filtration media.
c
u
m
u
l
a
t
i
v
e

v
o
l
u
m
e
t
r
i
c

e
f
f
i
c
i
e
n
c
y

o
f

p
a
r
t
i
c
l
e
s

>
D
p
Liquid Separation
Particle diameter Dp [m]
Test method and apparatus: according to VDI 3926 testing
standards of filtration media.
c
u
m
u
l
a
t
i
v
e

v
o
l
u
m
e
t
r
i
c

e
f
f
i
c
i
e
n
c
y

o
f

p
a
r
t
i
c
l
e
s

>
D
p
Particle Separation
Particle diameter Dp [m]
Product Specifications:
Materials of Construction
Prefilter Media (3): pleated microfiberglass coalescing media, a resin
impregnated cellulose support layer and a polyester drainage layer.
Coalescing Media (6): densely wrapped layers of glass microfibers
Inner Core (4): Q235 perforated galvanized steel
Outer Core (5): Q235 perforated galvanized steel
End Caps (1): Q235 galvanized sheet steel
Gaskets (2): Wool felt
Performance Specifications:
Filter efficiency: refer to graph
Flow direction: from inside to outside
Maximum allowable differential pressure: 2.0 bar
Recommended change cartridge differential pressure: 800-1000 mbar
Maximum operating temperature: 70

C ;
short peak temperatures of max. 90

C (max. 20 min.) are acceptable.


F I L T R A T I O N
Medium Temperature Coalescer Filter Cartridges
Available Dimensions:
Inside / outside diameter [mm]: 90/150
Lengths [mm]: 600, 735, 835, 1100
Additional sizes upon request.
The P-DLS MT seri es i s a cost ef f ecti ve coalescer f i lter that removes
parti c les f rom moi st natu ral gas wi th an u ltra hi gh ef f i c i enc y whi le
simultaneously presenting a very low restriction to the gas flow, resulting
in low pressure drop.
This filter is recommended for low temperature applications with peak
temperatures up to 150

C. It's high performance is two-phased: Pre-filtering


and Coalescing.
Pre-filtering removes dirt particles using a three layered pre-filter that
is composed of resin impregnated pleated cellulose, polyester and glass
mi crof i bers. The second coalesci ng phase uti li zes a densely wrapped
fiberglass for maximum efficiency. A cotton sock forms the most outer
layer of the filter to absorb the coalesced moisture.
Due to its high effective filtration area and high efficiency media, this
filter provides a low saturated pressure drop and a consistent high solid
and li qu i d removal ef f i c i enc y whi c h ensu res opti mu m protec ti on of
downstream equipment.
Test method and apparatus: according to VDI 3926 testing
standards of filtration media.
c
u
m
u
l
a
t
i
v
e

v
o
l
u
m
e
t
r
i
c

e
f
f
i
c
i
e
n
c
y

o
f

p
a
r
t
i
c
l
e
s

>
D
p
Liquid Separation
Particle diameter Dp [m]
Test method and apparatus: according to VDI 3926 testing
standards of filtration media.
c
u
m
u
l
a
t
i
v
e

v
o
l
u
m
e
t
r
i
c

e
f
f
i
c
i
e
n
c
y

o
f

p
a
r
t
i
c
l
e
s

>
D
p
Particle Separation
Particle diameter Dp [m]
Product Specifications:
Materials of Construction
Prefilter Media (3): pleated microfiberglass coalescing media, a resin
impregnated cellulose support layer and a polyester drainage layer.
Coalescing Media (6): densely wrapped layers of glass microfibers
Inner Core (4): Q235 perforated galvanized steel
Outer Core (5): Q235 perforated galvanized steel
End Caps (1): Q235 galvanized sheet steel
Gaskets (2): Wool felt
Performance Specifications:
Filter efficiency: refer to graph
Flow direction: from inside to outside
Maximum allowable differential pressure: 2.0 bar
Recommended change cartridge differential pressure: 800-1000 mbar
Maximum operating temperature: 120

C ;
short peak temperatures of max. 150

C (max. 20 min.) are acceptable.


F I L T R A T I O N
High Temperature Coalescer Filter Cartridges
The P-DLS HT seri es i s a cost ef f ecti ve coalescer f i lter that removes
parti c les f rom moi st natu ral gas wi th an u ltra hi gh ef f i c i enc y whi le
simultaneously presenting a very low restriction to the gas flow, resulting
in low pressure drop.
This filter is recommended for high temperature applications with peak
temperatures up to 190

C. It's co-pleated construction of reinforced Poly


Phenyl Sulfi de (PPS) felt medi a and densely wrapped fi berglass offers
maximum filtration performance. A terylene sock forms the most outer
layer of the filter to absorb the coalesced moisture.
Due to its high effective filtration area and high efficiency media, this
filter provides a low saturated pressure drop and a consistent high solid
and li qu i d removal ef f i c i enc y whi c h ensu res opti mu m protec ti on of
downstream equipment.
Product Specifications:
Materials of Construction
Filter Media: Reinforced PPS felt (3) with an outer core of ultra fine
fiberglass and polyster (6).
Inner Core (4): Q235 perforated galvanized steel
Outer Core (5): Q235 perforated galvanized steel
End Caps (1): Q235 galvanized sheet steel
Gasket (2): PPS
Available Dimensions:
Inside / outside diameter [mm]:
90/150; 170/230
Lengths [mm]: 600, 735, 835, 1100
Additional sizes upon request.
Performance Specifications:
Filter efficiency: refer to graph
Flow direction: from inside to outside
Maximum allowable differential pressure: 2.0 bar
Recommended change cartridge differential pressure: 800-1000 mbar
Maximum operating temperature: 170

C ;
short peak temperatures of max. 190

C (max. 20 min.) are acceptable.


Test method and apparatus: according to VDI 3926 testing
standards of filtration media.
c
u
m
u
l
a
t
i
v
e

v
o
l
u
m
e
t
r
i
c

e
f
f
i
c
i
e
n
c
y

o
f

p
a
r
t
i
c
l
e
s

>
D
p
Particle Separation
Particle diameter Dp [m]
Test method and apparatus: according to VDI 3926 testing
standards of filtration media.
c
u
m
u
l
a
t
i
v
e

v
o
l
u
m
e
t
r
i
c

e
f
f
i
c
i
e
n
c
y

o
f

p
a
r
t
i
c
l
e
s

>
D
p
Liquid Separation
Particle diameter Dp [m]
Steenoven 11
5626 DK, Eindhoven
The Netherlands
Tel +31 1825 65395
Fax +31 1825 65325
www.petrogas.nl
F I L T R A T I O N