Centrifugal Pumps: Installation and Use Performance Range

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

CP

Centrifugal pumps

PERFORMANCE RANGE

INSTALLATION AND USE

Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made.
As a result of their reliability and the fact that they are easy to use,
these pumps are widely used in domestic and civil applications
such as the distribution of water in combination with small and
medium sized pressure sets, for transferring liquids and for the irrigation of gardens and allotments.
The pump should be installed in an enclosed environment, or at
least sheltered from inclement weather.

Flow rate up to 160 l/min (9.6 m/h)


Head up to 58 m

APPLICATION LIMITS

Manometric suction lift up to 7 m


Liquid temperature between -10 C and +90 C
(up to +40 for the version with the technopolymer impeller)
Ambient temperature up to +40 C
Max. working pressure:
6 bar for CP 100-130-132-150-158
10 bar for CP 170-190-200
Continuous service S1

PATENTS - TRADE MARKS - MODELS

Registered Community Design n 406160-0001

CONSTRUCTION AND SAFETY STANDARDS

OPTIONALS AVAILABLE ON REQUEST

EN 60034-1
IEC 60034-1
CEI 2-3

CERTIFICATIONS

GUARANTEE

Special mechanical seal


Other voltages or 60 Hz frequency
IP55 class protection for CP 170, CP 170M

2 years subject to terms and conditions

40

50 Hz

n= 2900 1/min HS= 0 m

Head H (metres) 

CHARACTERISTIC CURVES AND PERFORMANCE DATA

Flow rate Q 

MODEL
Single-phase Three-phase
CPm 100

CPm 130
CP 130
CPm 132A CP 132A
CPm 150
CP 150
CPm 158
CP 158
CPm 170
CP 170
CPm 170M CP 170M
CPm 190
CP 190

CP 200

POWER
kW
0.25
0.37
0.60
0.75
0.75
1.1
1.1
1.5
2.2

HP
0.33
0.50
0.85
1
1
1.5
1.5
2
3

m/h

0.6

1.2

1.8

2.4

3.0

3.6

4.2

4.8

5.4

6.0

l/min

10

20

30

40

50

60

70

80

90

100 110 120 130 140 150 160

6.6

7.2

7.8

8.4

14

16

15

14

12.5

11

23

22

21

20

19

18

17

15.5

23

22

21.5

21

20

19

18

17

16

14

12

29.5

29

28.5

28

26

24.5

23

21

18

15

H metres 36

34

33.5

33

30

28.5

27

25

41

38

35

33.5

32

30

27.5

25

22

36

35

34.5 33.5

33

32

31

30

29

28

26.5

25

23

50

46

44.5

41.5

40

38

36

34.5 32.5 30.5

28

26

58

55

54.5 53.5

52

51

49.5

48

Q = Flow rate H = Total manometric head HS = Suction height

27.5 26.5

32.5 31.5
37

36
43

46

44.5 42.5 40.5 38.5

9.0

21

9.6

19

36

Tolerance of characteristic curves in compliance with EN ISO 9906 App. A.

41

CP
POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1

BODY BACKPLATE

Stainless steel AISI 304 (cast iron for CP 170-170M-190-200)

IMPELLER

Stainless steel AISI 304

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

MECHANICAL SEAL

Pump

Seal

Shaft

Model

Model

Diameter

CP 100-130-132A
CP 150-158
CP 170-170M-190-200

AR-12
AR-14
FN-18

12 mm
14 mm
18 mm

Pump

Model

CP 100-130-132A
CP 150-158
CP 170-170M
CP 190-200

6201 ZZ / 6201 ZZ
6203 ZZ / 6203 ZZ
6204 ZZ / 6204 ZZ
6304 ZZ / 6204 ZZ

Pump

Capacitance

BEARINGS

CAPACITOR

ELECTRIC MOTOR

Materials
Stationary ring

Rotational ring

Elastomer

Ceramic
Ceramic
Graphite

Graphite
Graphite
Ceramic

NBR
NBR
NBR

Single-phase

(230 V or 240 V)

(110 V)

CPm 100
CPm 130
CPm 132A
CPm 150-158
CPm 170-170M
CPm 190

10 F 450 VL
10 F 450 VL
14 F 450 VL
20 F 450 VL
25 F 450 VL
45 F 450 VL

25 F 250 VL
30 F 250 VL
30 F 250 VL
60 F 300 VL
60 F 250 VL
80 F 250 VL

CPm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding.
CP: three-phase 230/400 V - 50 Hz.
Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance
Insulation: F class.
Protection: IP 44.

42

DIMENSIONS AND WEIGHT


f

DN2

h1

DN1

h2

n1

MODEL

PORTS

Single-phase

Three-phase

CPm 100
CPm 130
CPm 132A
CPm 150
CPm 158
CPm 170 - 170M
CPm 190

CP 130
CP 132A
CP 150
CP 158
CP 170 - 170M
CP 190
CP 200

DN1

DIMENSIONS mm

DN2

259
1

h1

205

82

h2
123

n
165

kg
n1

135

41

42

10

51

285

240

92

148

190

160

38

367

260

110

150

206

165

44.5

364

290

115

175

242

206

32.5

11

1~

3~

6.9
7.6
8.3
12.4
12.0
17.8
22.3

7.1
8.0
11.4
11.0
17.2
21.3
22.5

ABSORPTION
MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

240 V

415 V

CPm 100
CPm 130
CPm 132A
CPm 150
CPm 158
CPm 170 - 170M
CPm 190

1.9 A
3.2 A
3.5 A
5.7 A
6.0 A
7.8 A
11.0 A

1.55 A
2.9 A
3.2 A
5.4 A
5.8 A
7.2 A
10.0 A

3.3 A
6.4 A
7.0 A
11.4 A
12.0 A
16.0 A
22.0 A

CP 130
CP 132A
CP 150
CP 158
CP 170 - 170M
CP 190
CP 200

2.0 A
2.9 A
4.2 A
4.4 A
5.2 A
7.5 A
9.0 A

1.2 A
1.7 A
2.4 A
2.5 A
3.0 A
4.3 A
5.2 A

1.8 A
2.4 A
4.1 A
4.3 A
5.1 A
7.3 A
8.3 A

1.1 A
1.4 A
2.4 A
2.5 A
2.9 A
4.2 A
4.8 A

PALLETIZATION
MODEL
Three-phase

CP 130
CP 132A
CP 150
CP 158
CP 170
CP 170M
CP 190
CP 200

H
(mm)

105
105
105
70
70
50
50
36
36

1280
1280
1280
1450
1450
1560
1560
1410
1410

CONTAINER
kg

1~
741
820
890
890
860
900
940
820

3~

770
860
820
790
870
910
790
830

n
pumps

H
(mm)

189
189
189
112
112
70
70
54
54

2190
2190
2190
2240
2240
2120
2120
2040
2040

kg
1~
3~
1321

1460 1360
1590 1530
1410 1300
1360 1250
1250 1200
1310 1260
1220 1170

1240




Single-phase
CPm 100
CPm 130
CPm 132A
CPm 150
CPm 158
CPm 170
CPm 170M
CPm 190