PIPE SPACING BASED ON 300# FLANGES STAGGERED

(SUITABLE FOR 150# & 400#) (mm)


PIPE
SIZE

1
1/2"

1"

2"

2
1/2"

3"

4"

6"

8"

10"

STANDARD PIPE SIZE AND WALL THICKNESS IN mm


(ASME 36.10)
12"

14"

16"

18"

20"

22"

NPS
Inch

24"

OD
mm

STD

XS

XXS

40

150# FLANGES (ASME 16.5)

300# FLANGES (ASME 16.5)

80
Y(mm)

No. &

Y(mm)

No. &

24"

500 505 515 520 525 540 565 590 620 645 660 685 710 735 760 785

1/2

21.30

2.77

3.73

7.47

2.77

3.73

NPS

22"

460 470 475 680 490 500 530 555 580 605 625 650 675 700 725

3/4

26.70

2.87

3.91

7.82

2.87

3.91

Inch

mm

mm

Neck

Thrd.

20"

430 435 445 450 455 470 495 520 550 575 590 615 655 680

33.40

3.38

4.55

9.09

3.38

4.55

1/2

89

11

48

16

16

60

4 - 16

18"

395 405 410 420 425 440 465 490 520 545 560 585 630

1 1/4

42.20

3.56

4.85

9.70

3.56

4.85

3/4

98

13

52

16

16

70

16"

365 375 380 390 395 405 435 460 485 510 525 550

1 1/2

48.30

3.68

5.08 10.15

3.68

5.08

108

14

56

17

17

14"

335 340 345 355 360 375 400 425 455 480 495

60.30

3.91

5.54 11.07

3.91

5.54

1 1/4

117

16

57

21

12"

305 310 315 320 330 345 370 395 445 470

2 1/2

73.00

5.16

7.01 14.02

5.16

7.01

1 1/2

127

17

62

10"

265 270 275 285 290 325 355 380 420

88.90

5.49

7.62 15.24

5.49

7.62

152

19

8"

235 240 245 255 260 275 310 335

3 1/2

101.60

5.74

8.08

5.74

8.08

2 1/2

178

6"

200 210 215 220 230 260 285

114.30

6.02

8.56 17.12

6.02

8.56

4"

170 175 180 190 195 230

141.30

6.55

9.53 19.05

6.55

9.53

3"

150 155 160 170 175

168.30

7.11 10.97 21.95

7.11

2 1/2"

140 145 150 160

219.10

8.18 12.70 22.23

10

273.10

9.27 12.70 25.40

12

323.90

9.53 12.70 25.40

10.31

17.48

343

29

102

44

44

298

8-22

381

41

111

62

62

330

12-25

14

355.60

9.53 12.70

11.13

19.05

10

406

30

102

49

49

362

12-25

10

445

48

117

67

95

387

16-29

125

B
(SEE NOTE 1)

NOTES

1. SPACING SHALL BE INCREASED WHEN:


C

A) BOTH LINES ARE INSULATED AND FLANGES ARE


UNINSULATED, ADD GREATEST INSULATION THICKNESS ONLY

ADD BOTH INSULATION THICKNESSES,

SPACING

BLIND FLANGE

FLANGE
SEE
TABLE

(SEE NOTE 1)

(SEE NOTE 1)

LAP JOINT FLANGE

SLIP ON FLANGE

THREADED FLANGE

1/2
1/2

mm

mm

Neck

Thrd.

1/2

95

14

52

22

22

67

4 - 16

4 - 16

3/4

117

16

57

25

25

83

4 - 19

79

4 - 16

124

17

62

27

27

89

4 - 19

21

89

4 - 16

1 1/4

133

19

65

27

27

98

4 - 19

22

22

98

4 - 16

1 1/2

156

21

68

30

30

114

4 -22

64

25

25

121

4-19

165

22

70

33

33

127

8-19

22

70

29

29

140

4-19

2 1/2

191

25

76

38

38

149

8-22

191

24

70

30

30

152

4-19

210

29

79

43

43

168

8-22

3 1/2

216

24

71

32

32

178

8-19

3 1/2

229

30

81

44

44

184

8-22

10.97

229

24

76

33

33

191

8-19

254

32

86

48

48

200

8-22

8.18

12.70

254

24

89

37

37

216

8-22

279

35

98

51

51

235

8-22

9.27

15.09

279

25

89

40

40

241

8-22

318

37

98

52

52

270

12-22

Joint Circle Holes

406.40

9.53 12.70

12.70

21.44

12

483

32

114

56

56

432

12-25

12

521

51

130

73

102

451

16-32

457.20

9.53 12.70

14.27

23.83

14

533

35

127

57

79

476

12-29

14

584

54

143

76

111

514

20-32

15.09

20

508.00

9.53 12.70

22
24

558.80

9.53 12.70

609.60

9.53 12.70

17.48

26.19

16

597

37

127

64

87

540

16-29

16

648

57

146

83

121

572

20-35

28.58

18

635

40

140

68

97

578

16-32

18

711

60

159

89

130

629

24-35

30.96

20

699

43

144

73

103

635

20-32

20

775

64

162

95

140

686

24-35

24

813

48

152

83

111

749

20-35

24

914

70

168

106

152

813

24-41

BUTT WELDED TEE AND REDUCERS (ASME 16.9)


NPS Outlet
C
M
H
NPS Outlet

VAPOUR
SERVICE
FT
M
21 6.4
24 7.3
26 7.9
30 9.1
32 9.8
35 10.7
37 11.3
39 11.9
42 12.8

mm
--25
32
38
51
64
76
89
102
127
152
203
254
305
356
406
457
508
610

mm
25
25
38
38
38
38
38
51
64
64
76
89
102
127
152
165
178
203
229
267

mm
35
43
51
64
73
92
105
127
140
157
186
216
270
324
381
413
470
533
584
692

WATER
SERVICE
FT
M
17 5.2
19 5.8
22 6.1
23
7
25 7.6
27 8.2
28 8.5
30 9.1
32 9.8

mm
16
11
22
25
29
35
44
51
57
64
79
95
127
159
191
222
254
286
318
381

NPS
inch
6
8
10
12
14
16
18
20
24

mm
38
29
38
48
57
76
95
114
133
152
191
229
305
381
457
533
610
686
762
914

VAPOUR
SERVICE
FT
M
8
2.4
8
2.4
8
2.4
9
2.7
9
2.7
9
2.7
12 3.7
13
4
14 4.3
15 4.6
16 4.9
17 5.2
19 5.8

inch
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24

90 L.R. ELBOW

1/4
1/2

Inch

CAP

45 L.R. ELBOW 90 S.R. ELBOW

inch
3/4
3/4
1
1
1
1 1/4
|
|
1 1/4
1 1/2
|
|
|
1 1/2
2
|
|
|
2
2 1/2
|
|
|
2 1/2
3
|
|
|
3
3 1/2
|
|
|
3 1/2

inch
3/4
1/2
1
3/4
1/2
1 1/4
1
3/4
1/2
1 1/2
1 1/4
1
3/4
1/2
2
1 1/2
1 1/4
1
3/4
2 1/2
2
1 1/2
1 1/4
1
3
2 1/2
2
1 1/2
1 1/4
3 1/2
3
2 1/2
2
1 1/2

mm
29
29
38
38
38
48
48
48
48
57
57
57
57
57
64
64
64
64
64
76
76
76
76
76
86
86
86
86
86
95
95
95
95
95

mm
-29

mm
-38

38
38
-48
48
48
-57
57
57
57
-60
57
51
44
-70
67
64
57
-83
76
73
70
-92
89
83
79

51
51
-51
51
51
-64
64
64
64
-76
76
76
76
-89
89
89
89
-89
89
89
89
-102
102
102
102

inch
4
|
|
|
|
4
5
|
|
|
|
5
6
|
|
|
|
6
8
|
|
|
8
10
|
|
|
10
12
|
|
|
12

inch
4
3 1/2
3
2 1/2
2
1 1/2
5
4
3 1/2
3
2 1/2
2
6
5
4
3 1/2
3
2 1/2
8
6
5
4
3 1/2
10
8
6
5
4
12
10
8
6
5

NPS

Outlet

mm
105
105
105
105
105
105
124
124
124
124
124
124
143
143
143
143
143
143
178
178
178
178
178
216
216
216
216
216
254
254
254
254
254

mm
-102
98
95
89
86
-117
114
111
108
105
-137
130
127
124
121
-168
162
156
152
-203
194
191
184
-241
229
219
216

mm
-102
102
102
102
102
-127
127
127
127
127
-140
140
140
140
140
-152
152
152
152
-178
178
178
178
-203
203
203
203

inch
14
|
|
|
14
16
|
|
|
|
16
18
|
|
|
|
18
20
|
|
|
|
|
20
24
|
|
|
|
|
24

inch
14
12
10
8
6
16
14
12
10
8
6
18
16
14
12
10
8
20
18
16
14
12
10
8
24
20
18
16
14
12
10

mm
279
279
279
279
279
305
305
305
305
305
305
343
343
343
343
343
343
381
381
381
381
381
381
381
432
432
432
432
432
432
432

mm
-270
257
248
238
-305
295
283
273
264
-330
330
321
308
298
-368
356
356
346
333
324
-432
419
406
406
397
384

mm
-330
330
330
330
-356
356
356
356
356
-381
381
381
381
381
-508
508
508
508
508
508
-508
508
508
508
508
508

STRAIGHT TEE

REDUCING TEE

CONC. REDUCER

ECCENTRIC REDUCER

REV : R0
DATE :13/09/05
PAGE : 1 OF 1

1
1
1
2
2
3
3
4
5

WATER
SERVICE
FT
M
7
2.1
7
2.1
7
2.1
7
2.1
7
2.1
7
2.1
9
2.7
10
3
11 3.4
12 3.7
13
4
14 4.3
16 4.9

Joint Circle Holes

MAXIMUM HORIZONTAL PIPE HANGER AND


SUPPORT SPACING FOR STD WEIGHT STEEL PIPE (MSS-SP-69)

NPS
inch
1/4
3/8
1/2
3/4

Size of

PIPE INSULATED

25 mm

PIPE

Bolt

16

BUTT WELDED FITTINGS (ASME 16.9)


NPS
A
B
D
E

PIPE UNINSULATED

Weld Slip on Lap

18

WELD NECK FLANGE

C) ONE LINE ONLY INSULATED, ADD INSULATION THICKNESS.

PIPE DATA

B) BOTH LINES ARE INSULATED AND FLANGES ARE INSULATED,

135 140

1"

NPS

1 1/2"

VALVE SPACING

Size of

140 145 155

PIPE & FLANGE


INSULATED

Bolt

2"

100 mm

Weld Slip on Lap

You might also like