Enhancement of Heat Transfer Using Artificial Roughness in Solar Air Heater
Enhancement of Heat Transfer Using Artificial Roughness in Solar Air Heater
Enhancement of Heat Transfer Using Artificial Roughness in Solar Air Heater
th
thermal efficiency
dynamic viscosity, Ns/m
2
density of air, kg/m
3
angle of attack, degree
REFERENCES
[1] Prasad BN, Saini JS. Effect of artificial roughness on heat transfer and friction factor in a solar air heater. Sol Energy 1988;
41(6):55560.
[2] Sahu MM, Bhagoria JL. Augmentation of heat transfer coefficient by using 90_broken transverse ribs on absorber plate of solar air
heater. Renew Energy 2005; 30:205763.
[3] Varun, Saini RP, Singal SK. Investigation of thermal performance of solar air heater having roughness elements as a combination of
inclined and transverse ribs on the absorber plate. Renew Energy 2008; 33:1398405.
[4] Kumar ST, Mittal V, Thakur NS, Kumar A. Heat transfer and friction factor correlations for rectangular solar air heater duct having
60_ inclined continuous discrete rib arrangement. Br J Appl Sci Technol 2011; 3:67-93.
[5] Aharwal KR, Gandhi BK, Saini JS. Experimental investigation on heat-transfer enhancement due to a gap in an inclined continuous
rib arrangement in a rectangular duct of solar air heater. Renew Energy 2008; 33:58596.
[6] Gupta D, Solanki SC, Saini JS. Thermo hydraulic performance of solar air heaters with roughened absorber plates.Solar Energy
1997; 61:33-42.
Enhancement of Heat Transfer Using
www.ijesi.org 63 | Page
[7] Momin AME, Saini JS, Solanki SC. Heat transfer and friction in solar air heater duct with V-shaped rib roughness on absorber
plate. Int J Heat Mass Transf 2002; 45:338396.
[8] Singh S, Chander S, Saini JS. Heat transfer and friction factor correlations of solar air heater ducts artificially roughened with
discrete V-down ribs. Energy. 2011; 36:5053e64.
[9] Karwa R. Experimental studies of augmented heat transfer and friction in asymmetrically heated rectangular ducts with ribs on the
heated wall in transverse, inclined, v-continuous and v-discrete pattern. Int Comm Heat Mass Transf 2003; 30(2):24150.
[10] Lau SC, McMillin RD, Han JC. Turbulent heat transfer and friction in a square channel with discrete rib turbulators.Trans ASME J
Turbo Machi 1991; 113:360-6.
[11] Saini SK, Saini RP. Development of correlations for Nusselt number and friction factor for solar air heater with roughened duct
having arc-shaped wire as artificial roughness. Sol Energy 2008; 82:111830.
[12] Kumar A, Bhagoria JL, Sarviya RM. International 19th national & 8th ISHMTASME heat and mass transfer conference heat
transfer enhancement in channel of solar air collector by using discrete w-shaped artificial roughened absorber 2008.
[13] Saini RP, Saini JS. Heat transfer and friction factor correlations for artificially roughened ducts with expended metal mesh as
roughness element. Int J Heat Mass Transf 1997; 40(4):97386.
[14] Bhagoria JL, Saini JS, Solanki SC. Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct
having transverse wedge shaped rib roughness on the absorber plate. Renew Energy 2002; 25:34169.
[15] Karwa R, Solanki SC, Saini JS. Heat transfer coefficient and friction factor correlations for the transitional flow regime in rib-
roughened rectangular ducts. Int J Heat Mass Transf 1999; 42:1597615.
[16] Jaurker AR, Saini JS, Gandhi BK. Heat transfer and friction characteristics of Energy 2006; 80(8):895907.
[17] Layek A, Saini JS, Solanki SC. Second law optimization of a solar air heater having chamfered rib-groove roughness on absorber
plate. Renew Energy 2007; 32:196780.
[18] Saini RP, Verma J. Heat transfer and friction factor correlations for a duct having dimple-shape artificial roughness for solar air
heaters. Energy2008; 33:127787.
[19] Bopche SB, Tandale MS. Experimental investigations on heat transfer and friction characteristics of a tabulator roughened solar air
heater. Int J Heat Mass Tran 2009;67:39.
[20] Sriromreun P, Promvong P. Augmented heat transfer in rectangular duct with angled Z-shaped ribs. Int Conf Energ Sust Dev; 2e4
June, 2010 [Thailand].
[21] Karwa R, Solanki SC, Saini JS. Thermo-hydraulic performance of solar air heaters having integral chamfered rib roughness on
absorber plates. Energy 2001;26:16176.
[22] Karmare SV, Tikekar AN. Heat transfer and friction factor correlation for artificially roughened duct with metal grit ribs. Int J Heat
Mass Transf 2007; 50:434251.
[23] Sukhmeet Singh, Subhash Chander, J.S. Saini.Heat transfer and friction factor correlations of solar air heater ducts artificially
roughened with discrete V-down ribs. 2011; Energy 36 (2011) 5053-5064
[24] Pongjet Promvonge. Heat transfer and pressure drop in a channel with multiple 60 V-baffles; International Communications in
Heat and Mass Transfer 37 (2010) 835840