70009

Rev 70009-20080529
10006 Santa Fe Springs Road
Santa Fe Springs, CA 90670 USA
Made in China
2200 Peak Watts/1900 Running Watts
PORTABLE GENERATOR
Owners Manual and Operating Instructions

Tabl e of Cont ent s

Introduction ..................................... 1
Portable Power Generator ........................ 1
Accessories ................................................ 1
This Booklet .............................................. 1
Manual Conventions ......................... 2
Safety Rules ...................................... 3
Controls and Features ....................... 5
Generator .................................................. 5
Power Panel .............................................. 6
Parts Included .......................................... 7
Assembly .......................................... 8
Remove the Generator from
the Shipping Carton .................................. 8
Install the Wheel Kit ................................. 8
Install the Support Leg ............................. 8
Install the Spark Arrester ......................... 8
Add Engine Oil ......................................... 8
Connect LPG cylinder ............................... 9
Grounding ................................................. 9
Operation ....................................... 10
Generator Location ................................. 10
Grounding ............................................... 10
Surge Protection ..................................... 10
Starting the Engine ................................. 10
Connecting Electrical Loads ................... 10
Stopping the Engine ............................... 10
Do Not Overload Generator .................... 11
Capacity ................................................ 11
Power Management ............................. 11
Wattage Reference Chart ........................ 12
Maintenance ................................... 13
Engine Maintenance ............................... 13
Oil ........................................................ 13
Spark Plugs ......................................... 13
Air Filter .............................................. 13
Spark Arrester ..................................... 14
Cleaning .............................................. 14
Adjustments ........................................ 14
Maintenance Schedule ........................ 14
Generator Maintenance .......................... 14
Storage ........................................... 15
Engine Storage ........................................ 15
Generator Storage ................................... 15
Specifications ................................. 16
Engine Specifications .............................. 16
Generator Specifications ......................... 16
Fuel .......................................................... 16
Oil ............................................................ 16
Spark Plugs ............................................. 16
Valve Clearance ....................................... 16
Parts Diagram ......................................... 17
Parts List ................................................. 18
Wiring Diagram ..................................... 20
Troubleshooting ............................. 21
Warranty ........................................ 22
Warranty Qualifications ......................... 22
Repair/Replacement Warranty .............. 22
Do not return the unit to the place of
purchase .................................................. 22
Warranty Exclusions ............................... 22
Normal Wear ....................................... 22
Installation, Use and Maintenance ..... 22
Other Exclusions ................................. 22
Limits of Implied Warranty and
Consequential Damage ........................... 22
Contact Information ............................... 22
Address ................................................ 22
Customer Service ................................ 22
Technical Service ................................. 22
Notes .............................................. 23


I nt r oduc t i on
Rev 70009-20080529 1
I nt r oduc t i on
Congratulations on your purchase of a
Champion Power Equipment generator. CPE
designs and builds generators to strict
specifications. With proper use and
maintenance, this generator will bring years
of satisfying service.
Portable Power Generator
This unit is a liquefied petroleum gas (LPG)
engine driven, alternating current (AC)
generator. It is designed to supply electrical
power for lighting, appliances, tools and
similar equipment.
Accessories
Champion Power Equipment manufactures
and sells accessories designed to help you
get the most from your purchase. To find out
more about our covers, power cables and
storm kits, please visit our web site at

www.championpowerequipment.com
This Booklet
Every effort has been made to ensure the
accuracy and completeness of the
information in this manual. We reserve the
right to change, alter and/or improve the
product and this document at any time
without prior notice.


Record the model and serial numbers as well as date and place of purchase for future reference.
Have this information available when ordering parts and when making technical or warranty
inquiries.

Champion Power Equipment Support
1-877-338-0999
Model Number
70009
Serial Number

Date of Purchase

Purchase Location


Manual Convent i ons
2 Rev 70009-20080529
Manual Convent i ons
This manual uses the following symbols to
help differentiate between different kinds of
information. The safety symbol is used with
a key word to alert you to potential hazards
in operating and owning power equipment.

Follow all safety messages to avoid or reduce
the risk of serious injury or death.
DANGER
DANGER indicates an imminently hazardous
situation which, if not avoided, will result in death
or serious injury.


WARNI NG
WARNING indicates a potentially hazardous
situation which, if not avoided, could result in
death or serious injury.

CAUTI ON
CAUTION indicates a potentially hazardous
situation which, if not avoided, may result in
minor or moderate injury.


CAUTI ON
CAUTION used without the safety alert symbol
indicates a potentially hazardous situation which,
if not avoided, may result in property damage.


NOTE
If you have questions regarding your generator,
we can help. Please call our help line at 1-877-
338-0999.


Saf et y Rul es
Rev 70009-20080529 3
Saf et y Rul es

WARNI NG
Read this manual thoroughly before operating
your generator. Failure to follow instructions
could result in serious injury or death.


WARNI NG
The engine exhaust from this product contains
chemicals known to the state of California to
cause cancer, birth defects, or other reproductive
harm.


DANGER
Generator exhaust contains carbon monoxide, a
colorless, odorless, poison gas. Breathing carbon
monoxide will cause nausea, dizziness, fainting or
death.
Operate generator outdoors only in a well
ventilated area
DO NOT operate the generator inside any
building, enclosure or compartment, including the
generator compartment of a recreational vehicle.
DO NOT allow exhaust fumes to enter a confined
area through windows, doors, vents or other
openings.

DANGER
Rotating parts can entangle hands, feet, hair,
clothing and/or accessories.
Traumatic amputation or severe laceration can
result.
Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
Operate equipment with guards in place.
DO NOT wear loose-fitting clothing, dangling
drawstrings or items that could become caught.

DANGER
Generator produces powerful voltage.
DO NOT touch bare wires or receptacles.
DO NOT use electrical cords that are worn,
damaged or frayed.
DO NOT operate generator in wet weather.
DO NOT allow children or unqualified persons to
operate or service the generator
Use a ground fault circuit interrupter (GFCI) in
damp areas and areas containing conductive
material such as metal decking.
Use approved transfer equipment to isolate
generator from your electric utility and Notify
your utility company before connecting your
generator to your power system.

WARNI NG
Sparks can result in fire or electrical shock.
When servicing the generator:
Disconnect the spark plug wire and place it
where it cannot contact the plug.
DO NOT check for spark with the plug removed.
Use only approved spark plug testers.

WARNI NG
Running engines produce heat.
Severe burns can occur on contact.
Combustible material can catch fire on contact.
DO NOT touch hot surfaces.
Avoid contact with hot exhaust gases.
Allow equipment to cool before touching.
Maintain at least three feet of clearance on all
sides to ensure adequate cooling.
Maintain at least five feet of clearance from
combustible materials.

Saf et y Rul es
4 Rev 70009-20080529
DANGER
Propane (LPG) is highly flammable and explosive.
Fire or explosion can cause severe burns or death
if the gas is ignited.
Before starting the generator
Turn the generator off.
Inspect your LPG tank for damage or leaks.
Attach only approved tanks that have been
properly filled by an approved station.
DO NOT light or smoke cigarettes.
Replace the hose at the first sign of a leak or if
age-cracking becomes apparent.
When starting the generator
DO NOT attempt to start a damaged generator.
Make certain that the LPG tank, air filter, spark
plug, fuel lines and exhaust system are properly
in place.
Make certain that the generator resting firmly on
level ground.
When operating the generator:
DO NOT move or tip the generator during
operation.
DO NOT tip the generator or allow oil to spill.
When transporting or servicing the
generator:
Make certain that the LPG tank is disconnected
and properly shut off.
Disconnect the spark plug wire.
When storing the generator:
Store away from sparks, open flames, pilot lights,
heat and other sources of ignition.

WARNI NG
Rapid retraction of the starter cord will pull hand
and arm towards the engine faster than you can
let go.
Unintentional startup can result in entanglement,
traumatic amputation or laceration.
Broken bones, fractures, bruises or sprains could
result.
When starting engine, pull the starter cord slowly
until resistance is felt and then pull rapidly to
avoid kickback.
DO NOT start or stop the engine with electrical
devices plugged in.

CAUTI ON
Exceeding the generators running capacity can
damage the generator and/or electrical devices
connected to it
DO NOT overload the generator.
Start the generator and allow the engine to
stabilize before connecting electrical loads.
Connect electrical equipment in the off position,
and then turn them on for operation.
Turn electrical equipment off and disconnect
before stopping the generator.
DO NOT tamper with the governed speed.
DO NOT modify the generator in any way.

CAUTI ON
Improper treatment or use of the generator can
damage it, shorten its life and void your
warranty.
Use the generator only for intended uses.
Operate only on level surfaces.
DO NOT expose generator to excessive moisture,
dust, or dirt.
DO NOT allow any material to block the cooling
slots.
If connected devices overheat, turn them off and
disconnect them from the generator.
DO NOT use the generator if:
Electrical output is lost
Equipment sparks, smokes or emits flames
Equipment vibrates excessively

Controls and Features
Rev 70009-20080529 5
Controls and Features
Read this owners manual before operating your generator. Familiarize yourself with the location
and function of the controls and features. Save this manual for future reference.
Generator
1
2
4
3
5
6
7
8
9
(1) Fuel Valve Turn this valve to the
On position to supply fuel to the engine.
(2) Choke Used to start the engine.
(3) Air Cleaner Protects the engine by
filtering dust and debris from the intake air.
(4) Recoil Starter Used to start the
engine
(5) Gas Hose and Regulator Protects
the engine by filtering dust and debris from
the intake air.
(6) Serial Number Please have this
number available when calling for
assistance.
(7) Low Oil Sensor Senses the level of
oil in the crankcase and shuts the engine
down if the level falls too low.
(8) Oil Filler Cap Check and fill engine
oil level.
(9) Power Panel See Power Panel
Controls and Features
6 Rev 70009-20080529
Power Panel
(1) Gas Inlet Nipple for LPG hose
connection.
(2) Intelligauge Three mode digital
meter for running hours, voltage and hertz.
(3) Parameter Button Push-button
selector for the Intelligauge.
(4) 120 V 30 A Twist-Lock protected by
a 16 A flip-to-reset circuit breaker, this
receptacle powers 120 Volt AC, 60 Hz, single
phase loads requiring up to 16 A or 1900
Watts of power.
(5) Circuit Breakers Protects the
generator against electrical overload.
(7) Ground Terminal Consult an
electrician for local grounding regulations.
1 2
3
4 5 6 7
(6) 120 V 20 A GFCI Duplexes this
duplex is protected by a 16 A circuit breaker.
Use this duplex to operate 120 Volt AC,
single phase, 60 Hz loads requiring up to
16 A 0r 1900 Watts of power.
Cont r ol s and Feat ur es
Rev 70009-20080529 7
Parts Included
Your Model 70009 LPG Powered Generator ships with the following parts:


Wheel Kit
Handle Assembly 1 set
6 Solid Wheel 2 piece
Axle Assembly 2 sets
Support Leg 1 piece
Vibration Mounts 2 piece
Support Leg Hardware 1 set

Oil Funnel 1 piece
Wrench 1 piece
Spark Plug Socket 1 piece

Spark Arrester Kit
Spark Arrester 1 piece
Cover Plate 1 piece
Screws, Lock Washers 2 pieces

Gas Hose and Regulator 1 piece


Assembly
8 Rev 70009-20080529
Assembly
Your generator requires some assembly.
This unit ships from our factory without oil.
It must be properly serviced with fuel and oil
before operation.
If you have any questions regarding the
assembly of your generator, call our help
line at 1-877-338-0999. Please have your
serial number and model number available.
Remove the Generator from
the Shipping Carton
1. Set the shipping carton on a solid, flat
surface.
2. Remove everything from the carton
except the generator.
3. Carefully cut each corner of the box
from top to bottom. Fold each side flat
on the ground to provide a surface area
to install the wheel kit and support leg.
Install the Wheel Kit
CAUTION
The wheel kit is not intended for over-the-road
use.
You will need the following tools to install
the wheels:
13 mm wrench
Socket wrench with a 14 mm socket
Pliers (not included)
1. Slide the M10x105 wheel bolt through
the washer, sleeve and wheel.
2. Slide the bolt through the mount point
on the frame.
3. Fasten securely with the 10mm nut.
4. Repeat steps 1-3 to attach the second
wheel.
Install the Support Leg
1. Attach the rubber vibration mount to
the support leg with a cap screw
(M8x32) and lock nut (M8).
2. Attach the support leg to the generator
frame with cap screws (M8x16) and lock
nuts (M8).
3. Tip the generator slowly so that it rests
on the wheels and support leg.
Install the Spark Arrester
Insert the spark arrester screen into the
muffler outlet. Secure the spark arrester by
placing the cover plate over the end of the
screen, with the lettering facing outward.
Secure the cover plate with the two screws
and lock washers provided with the spark
arrester kit.
NOTE
Federal and local laws and administrative
requirements indicate when and where spark
arresters are required. When ordered, spark
arresters are required for operation of this
generator in National Forest lands. In California,
this generator must not be used on any forest-
covered land, brush-covered land, or grass-
covered land unless the engine is equipped with
a spark arrester.
CAUTION
Failure to install the spark arrester may result in
an increased risk of fire..
Add Engine Oil
CAUTION
DO NOT attempt to crank or start the engine
before it has been properly filled with the
recommended type and amount of oil. Damage
to the generator as a result of failure to follow
these instructions will void your warranty.
1. Place the generator on a flat, level
surface.
2. Remove oil fill cap/dipstick to add oil.
Assembl y
Rev 70009-20080529 9
3. Add 0.63 qt (0.6 L) of oil and replace oil
fill cap/dipstick. See Specifications for
oil recommendations based on
operating conditions.
4. Check engine oil level daily and add as
needed.
CAUTI ON
The engine is equipped with a low-oil-shutoff and
the will stop when the oil level in the crankcase
falls below the threshold level.


NOTE
Check oil often during the break-in period. Refer
to the Maintenance section for recommended
service intervals.


NOTE
The generator rotor has a sealed, pre-lubricated
ball bearing that requires no additional lubrication
for the life of the bearing.

Connect LPG cylinder
This engine is certified to operate on liquid
petroleum gas (LPG).
1. Turn off the fuel valve on the generator.
2. Attach the LPG connector to the gas
inlet.
3. Open the manual shutoff valve on the
LPG cylinder.
4. Open the fuel valve on the generator.
WARNI NG
Liquefied Petroleum Gas is extremely flammable
and explosive.
If there is a strong smell of gas:
Close off the gas supply at the cylinder.
Use soapy water which will produce a large
bubble at the point of any leak, to check the
cylinder valve, connections and the generator.
Do not smoke or light a cigarette.
Contact a qualified technician to inspect and
repair the LPG system.

CAUTI ON
Use approved LP cylinders equipped with an OPD
(overfilling prevention device) valve.
Always keep the cylinder in a vertical position
with the valve on top and installed at ground
level on a flat surface
Cylinders must not be installed near any heat
source and should not be exposed to sun, rain,
dust and heat.
Regulators to be used on the cylinders must be
of the diameter as the cylinder valve.
Regulators should always be in the off position
when the cylinder is not in use.

Grounding
Your generator must be properly connected
to an appropriate ground to help prevent
electric shock.

WARNI NG
Failure to properly ground the generator can
result in electric shock.

A ground terminal connected to the frame of
the generator has been provided on the
power panel. For remote grounding, connect
of a length of heavy gauge (12 AWG
minimum) copper wire between the
generator ground terminal and a copper rod
driven into the ground. We strongly
recommend that you consult with a qualified
electrician to ensure compliance with local
electrical codes.

Oper at i on
10 Rev 70009-20080529
Oper at i on
Generator Location
Please consult your local authority. In some
areas, generators must be registered with
the local utility.
Generators used at construction sites may be
subject to additional rules and regulations.
This generator must have at least five feet of
clearance from combustible material. Leave
at least three feet of clearance on all sides of
the generator to allow for adequate cooling,
maintenance and servicing.
Place the generator in a well-ventilated area.
DO NOT place the generator near vents or
intakes where exhaust fumes could be drawn
into occupied or confined spaces. Carefully
consider wind and air currents when
positioning generator.

Grounding
The generator system ground connects the
frame to the ground terminals on the power
panel. The system ground is connected to
the AC neutral wire.
Surge Protection
CAUTI ON
Voltage fluctuation may impair the proper
functioning of sensitive electronic equipment.

Electronic devices, including computers and
many programmable appliances use
components that are designed to operate
within a narrow voltage range and may be
affected by momentary voltage fluctuations.
While there is no way to prevent voltage
fluctuations, you can take steps to protect
sensitive electronic equipment.

1. Install UL1449, CSA-listed, plug-in
surge suppressors on the outlets feeding
your sensitive equipment.
Surge suppressors come in single- or
multi-outlet styles. Theyre designed to
protect against virtually all short-
duration voltage fluctuations.
2. Obtain an Uninterruptible Power
Supply (UPS) device.
Most UPS devices come with a
rechargeable battery between the
electronic equipment and power supply
source. The device buffers the voltage
and protects against virtually all short-
duration voltage fluctuations.
Starting the Engine
1. Make certain the generator is on a flat,
level surface.
2. Disconnect all electrical loads from the
generator. Never start or stop the
generator with electrical devices plugged
in or turned on.
3. Open the manual shutoff valve on the
LPG cylinder.
4. Turn the fuel valve to the On position.
5. Move the choke lever to the Choke
position.
6. Pull the starter cord slowly until
resistance is felt and then pull rapidly
7. As engine warms up, move the choke
lever to Run.

NOTE
If the engine starts but does not run, make
certain that the generator is on a flat, level
surface. The engine is equipped with a low oil
sensor that will prevent the engine from running
when the oil level falls below a critical threshold.


Connecting Electrical Loads
1. Let the engine stabilize and warm up for
a few minutes after starting
2. Plug in and turn on the desired 120 Volt
AC single phase, 60 Hz electrical loads.
DO NOT connect 3-phase loads to the
generator.
DO NOT connect 50 Hz loads to the
generator.
DO NOT overload the generator.

Stopping the Engine
1. Turn off and unplug all electrical loads.
Never start or stop the generator with
electrical devices plugged in or turned
on.
Oper at i on
Rev 70009-20080529 11
2. Let the generator run at no-load for
several minutes to stabilize internal
temperatures of the engine and
generator.
3. Close the OPD valve on the LPG
cylinder.
4. Turn the fuel valve to the Off position.
Do Not Overload Generator
Capacity
Follow these simple steps to calculate the
running and starting watts necessary for
your purposes.
1. Select the electrical devices you plan on
running at the same time.
2. Total the running watts of these items.
This is the amount of power you need to
keep your items running.
3. Identify the highest starting wattage of
all devices identified in step 1. Add this
number to the number calculated in step
2. Surge wattage is the extra burst of
power needed to start some electric
driven equipment. Following the steps
listed under Power Management will
guarantee that only one device will be
starting at a time.
Power Management
Use the following formula to convert voltage
and amperage to watts:

Volts x Amps = Watts

To prolong the life of your generator and
attached devices, follow these steps to add
electrical load:
1. Start the generator with no electrical
load attached.
2. Allow the engine to run for several
minutes to stabilize.
3. Plug in and turn on the first item. It is
best to attach the item with the largest
load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional
item.
NOTE
Never exceed the generator capacity when
adding loads.

Oper at i on
12 Rev 70009-20080529
Wattage Reference Chart
Use the chart to determine approximate
wattage requirements for your equipment.
NOTE
Starting watts can exceed three times the
running watts. The values in the following table
are approximate. Refer to your tool or appliance
for actual wattage consumption.



I tem
Running
Watts
Starting
Watts
Essentials
Light Bulb 100W 100
Refrigerator/Freezer 1200 2400
Freezer 500 500
Sump Pump 600 1800
Well Pump 1 HP 2000 4000
Water Heater 4000
Security System 180
AM/FM Radio 300
Garage Door Opener 1/2 HP 500 600
Battery Charger 12V DC 110
Heating/ Cooling
Air Conditioner 12000 BTU 1700 2500
Fan 300 600
Furnace Fan 1/3 HP 1200 2000
Home Appliances
Microwave 1000W 1000
Electric Range - One Element 1500
Electric Skillet 1250
Coffee Maker 1500
Clothes Washer 1200
Entertainment
CD/DVD Player 100
VCR 100
Stereo Receiver 450
Television 27" 500
PC with 15" Monitor 800
J ob Site
Belt Sander 3" 1000 1500
Bench Grinder 6" 700 1500
Circular Saw 1500 1500
Compressor 1 1/2 HP 2500 2500
Edge Trimmer 500 500
Hand Drill 1/2" 1000 1000
Lawn Mower 1200 1800
Paint Sprayer 600 1200
Table Saw 2000 2000

Mai nt enanc e
Rev 70009-20080529 13
Mai nt enanc e
The owner/operator is responsible for all
periodic maintenance.
WARNI NG
Never operate a damaged or defective generator.


WARNI NG
Tampering with the factory set governor will void
your warranty.


WARNI NG
Improper maintenance will void your warranty.


Complete all scheduled maintenance in a
timely manner. Correct any issue before
operating the generator.

NOTE
For service or parts assistance, contact our help
line at 1-877-338-0999.

Engine Maintenance
To prevent accidental starting, remove and
ground spark plug wire before performing
any service.
Oil
Change oil when the engine is warm. Refer
to the oil specification to select the proper
grade of oil for your operating environment.
1. Remove the oil drain plug with a 15 mm
socket and extension.
2. Allow the oil to drain completely.
3. Replace the drain plug.
4. Remove oil fill cap/dipstick to add oil.
5. Add 0.63 qt (0.6 L) of oil and replace oil
fill cap/dipstick.
6. Dispose of used oil at an approved waste
management facility.


Spark Plugs
1. Remove the spark plug cable from the
spark plug.
2. Use the spark plug tool that shipped
with your generator to remove the plug.
3. Inspect the electrode on the plug. It
must be clean and not worn to produce
the spark required for ignition.
4. Make certain the spark plug gap is 0.7 -
0.8mm (0.028 - 0.031 in.).
5. Refer to the spark plug recommendation
chart when replacing the plug.
6. Carefully thread the plug into the
engine.
7. Use the spark plug tool to firmly install
the plug.
8. Attach the spark plug wire to the plug.
Air Filter
1. Remove the snap-on cover holding the
air filter to the assembly.
2. Remove the foam element.
3. Wash in liquid detergent and water.
Squeeze thoroughly dry in a clean cloth.
4. Saturate in clean engine oil.
5. Squeeze in a clean, absorbent cloth to
remove all excess oil.
6. Place the filter in the assembly.
7. Reattach the air filter cover and snap in
place.
Mai nt enanc e
14 Rev 70009-20080529
Spark Arrester
1. Allow the engine to cool completely
before servicing the spark arrester.
2. Remove the two screws holding the
cover plate which retains the end of the
spark arrester to the muffler.
3. Remove the spark arrester screen.
4. Carefully remove the carbon deposits
from the spark arrester screen with a
wire brush.
5. Replace the spark arrester if it is
damaged.
6. Position the spark arrester in the
muffler and attach with the two screws.
Cleaning
CAUTI ON
DO NOT spray engine with water.
Water can contaminate the fuel system.

Use a damp cloth to clean exterior surfaces
of the engine.
Use a soft bristle brush to remove dirt and
oil.
Use an air compressor (25 PSI) to clear dirt
and debris from the engine.
Adjustments
The air-fuel mixture is not adjustable.
Tampering with the governor can damage
your generator and your electrical devices
and will void your warranty. CPE
recommends that you contact our service
line at 1-877-338-0999 for all other service
and/or adjustment needs.
Maintenance Schedule
Follow the service intervals indicated in the
schedule below.
Service your generator more frequently
when operating in adverse conditions.
Contact our help line at 1-877-338-0999 to
locate the nearest Champion Power
Equipment certified service dealer for your
generator or engine maintenance needs.

Every 8 hours or daily
Check oil level
Clean around air intake and muffler
First 5 Hours
Change oil
Every 50 hours or every season
Clean air filter

Change oil if operating under heavy load
or in hot environments
Every 100 hours or every season
Change oil
Clean/Adjust spark plug
Check/Adjust valve clearance *
Clean spark arrester
Every 3 years
Replace fuel line

* To be performed by knowledgeable,
experienced owners or Champion Power
Equipment certified service dealers

Generator Maintenance
Make certain that the generator is kept clean
and stored properly. Only operate the unit
on a flat, level surface in a clean, dry
operating environment. DO NOT expose the
unit to extreme conditions, excessive dust,
dirt, moisture or corrosive vapors.
CAUTI ON
DO NOT use a garden hose to clean the
generator.
Water can enter the generator through the
cooling slots and damage the generator
windings.

Use a damp cloth to clean exterior surfaces
of the generator.
Use a soft bristle brush to remove dirt and
oil.
Use an air compressor (25 PSI) to clear dirt
and debris from the generator.
Inspect all air vents and cooling slots to
ensure that they are clean and unobstructed.
St or age
Rev 70009-20080529 15
St or age
The generator should be started at least once
every 14 days and allowed to run for at least
20 minutes. For longer term storage, please
follow these guidelines.

Engine Storage
1. Allow the engine to cool completely
before storage.
2. Clean the engine according to the
instructions in the Maintenance section.
3. Change the oil.
4. Remove the spark plug and pour about
ounce of oil into the cylinder. Crank
the engine slowly to distribute the oil
and lubricate the cylinder.
5. Reattach the spark plug.
Generator Storage
1. Allow the generator to cool completely
before storage.
2. Turn off the fuel supply at the fuel valve.
3. Clean the generator according to the
instructions in the Maintenance section.
4. Store the unit in a clean, dry area.
5. Store in a clean, dry place out of direct
sunlight.

Spec i f i c at i ons
16 Rev 70009-20080529
Spec i f i c at i ons
Engine Specifications
Engine 163 cc OHV CPE
Generator Specifications
Running Wattage 1900 Watts
Starting Wattage 2200 Watts
AC Load 120 V
Phase Single
Frequency 60 Hz
Fuel Capacity Liquefied Petroleum Gas
Weight 97 lbs. (44 kg)
Height 18.89 inches (48 cm)
Width 20.16 inches (51.2 cm)
Length 30.31 inches (77 cm)
Fuel
Use only an approved LPG cylinder
equipped with an OPD valve.
Flow rate: 2.0 kg/hr
Outlet pressure: 2.8 kpa 0.5 kpa
Oil
Oil capacity is 0.63 qt (0.6 L).


Spark Plugs
Your generator comes equipped with a
long reach plug (19mm)

Use only Green Power brand replacement
LPG spark plugs.

CAUTI ON
Failure to use the proper plug may damage your
engine and will void your warranty.

Make certain the spark plug gap is 0.7 -
0.8mm (0.028 - 0.031 in.).
Valve Clearance
Intake: 0.09 - 0.11 mm (.003 - .004 in.)
Exhaust: 0.11 - 0.13 mm (.004 - .005 in.)

Specifications
Rev 70009-20080529 17
Parts Diagram
Specifications
18 Rev 70009-20080529
Parts List
Item Part Number Description Qty
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
GB93-SW5
GB818-B5-16
ST188FD-1100010-88
ST168FD-1180121
ST168FD-1100101B
ST168FD-1100200B-1
ST168FD-1100103B
ST168FD-1100105B
GB5789-FB6-12
ST168FD-1100002B
ST02FD-1152035-CSA
ST02FD-1151036
ST02FD-1152002
GB5789-FB5-12
ST168FD-1150230-CSA
GB5781-B5-16
GB5781-B5-15
ST168FD-1152031-CSA
ST02FD-1152032
GB5789-FB6-133
ST02FD-1152001
ST02FD-1152020-CSA
GB5789-FB8-208
GB90-W8
GB279-88 6202
ST02FD-1152010-CSA
ST02FD-1152009
ST02FD-1152032-C
GB6177-N6
GB5789-FB6-12
ST02FD-1151207-M
ST05FD-1170003-B
ST05FD-1151209
ST02FD-1151201
ST05FD-1151208-M
ST02FD-05502030
ST02FD-05502020-CSA
2630
2631-1
CG500-031604F2
ST02FD-05032300
CG200-020203
ST188FD-1020001
ST02FD-1151206-F
ST05FD-1151220-CSA16
GB818-B5-35
GB6177-N8
ST02FD-1151300B
ST02FD-1151300A
ST02FD-03681000
ST168FD-1151301
Spring Washer 5
Bolt M516
Spark Arrester Cover
Spark Arrester Assembly
Muffler Outer Protector
Muffler
Muffler Inner Protector
Protector Seal
Flange Bolt M6X12
Muffler Stay
Brush Assembly
Brush Assembly Cover Board
Generator End Cover
Flange Bolt M512
Terminal
Bolt M516
Bolt M515
AVR
End Cover
Flange Bolt M6133
Stator Cover
Stator
Flange Bolt M8208
Washer 8
Bearing
Rotor Comp
Cooling Fan
Crankcase Cover
Nut M6
Flange Bolt M6X12
Earth Line
Grommet
Conduit (metal)
Grommet
Grounding Bolt
Receptacle GFCI
Receptacle L5-30R
Touch Switch
Trigital Meter
Gas Inlet
Control Panel
Rubber Tube I
Grommet
Wiring Contol Box
250V 16A DOUBLE POLE
Screw M535
Nut M8
Bottom Bubber I
Bottom Rubber II
Frame
Ornamental
2
2
1
1
1
1
1
2
22
1
1
1
1
2
1
2
2
1
1
4
1
1
1
1
1
1
1
1
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
16
2
2
1
2
Specifications
Rev 70009-20080529 19
Item Part Number Description Qty
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
ST02FD-1151201A
ST168FD-1130005
C200B2-000016A
ST168F-100000-LPG
ST160F-1100001
GB900-SB8-35
GB97.1-85-W8
GB93-SW8
GB6170-N8
ST168FD-1111100
ST168FD-1090100
ST168FD-1090002
ST168FD-1090003
ST168FD-1090004
ST168FD-1090200
GB818-2000-B4-8
GB/T93-SW4
GB/T97.1-W4
CG200-020202
CG500-000007
CG500-021700
CG200-020201
GB5789-FB8-45
ST02FD-1151400
GB5789-FB8-16
ST05FD-03020301-37
ST188FD-1743002-C
GB5789-FB8-32
GB/T6182-2000-N8
WP20-03270002
WP20-03270001
GB96-P8
GB5780-B8-75
ST168FD-1100106B
ST168FD-1100107B
Choke Lever Comp
Packing
Mixer
LPG Engine
Muffler Gasket
Stud Bolt M835
Washer 8
Spring washer 8
Nut M8
Control Assembly
Air Cleaner Case
Air Cleaner Seal
Separator
Element
Air Cleaner Cover
Screw M48
Spring Washer 4
Washer 4
Rubber Tube II
Clip
Switch
Middle Cover
Flange Bolt M845
Handle
Flange Bolt M816
Support Leg (1.45in)
Vibration Mount
Flange Bolt M832
Nut M8
6in Wheel (Solid)
Sleeve
Packing 8
Bolt M875
Shield (I)
Shield (II)
1
1
1
1
1
2
2
3
2
1
1
1
1
1
1
3
2
2
1
4
1
1
2
1
2
1
2
2
2
2
2
2
2
1
1
Specifications
20 Rev 70009-20080529
Wiring Diagram
Tr oubl eshoot i ng
Rev 70009-20080529 21
Tr oubl eshoot i ng

Problem Cause Solution
Generator will not start No fuel Add fuel
Faulty spark plug Replace spark plug
Unit loaded during start up Remove load from unit
Generator will not start;
Generator starts but runs roughly
Low oil level Fill crankcase to the proper level
Place generator on a flat, level surface
Choke in the wrong position. Adjust choke.
Spark plug wire loose Attach wire to spark plug
Generator shuts down during
operation
Out of fuel Fill fuel tank
Low oil level Fill crankcase to the proper level.
Place generator on a flat, level surface
Generator cannot supply enough
power or overheating
Generator is overloaded Review load and adjust. See Power
Management
Insufficient ventilation Check for air restriction. Move to a
well ventilated area
No AC output Cable not properly connected Check all connections
Connected device is defective Replace defective device
Circuit breaker is open Reset circuit breaker
Capacitor defective Replace capacitor (Service Center)
Faulty brush assembly Replace brush assembly (Service
Center)
Faulty AVR Replace AVR (Service Center)
Loose wiring Inspect and tighten wiring
connections
Other Contact the help line.
Generator gallops Engine governor defective Contact the help line
Repeated circuit breaker tripping Overload Review load and adjust. See Power
Management
Faulty cords or device Check for damaged, bare or frayed
wires. Replace defective device
War r ant y
22 Rev 70009-20080529
War r ant y
CHAMPION POWER EQUIPMENT
1 YEAR LIMITED WARRANTY

Effective September 1, 2006. Replaces all
undated warranties and all warranties dated
before September 1, 2006.
Warranty Qualifications
Champion Power Equipment (CPE) will register
this warranty upon receipt of your Warranty
Registration Card and a copy of your sales receipt
from one of CPE's retail locations as proof of
purchase.
Please submit your warranty registration and
your proof of purchase within ten (10) days of the
date of purchase.
Repair/Replacement Warranty
CPE warrants to the original purchaser that the
mechanical and electrical components will be free
of defects in material and workmanship for a
period of one (1) year from the original date of
purchase (90 days for commercial & industrial
use). Transportation charges on product
submitted for repair or replacement under this
warranty are the sole responsibility of the
purchaser. This warranty only applies to the
original purchaser and is not transferable.
Do not return the unit to the place
of purchase
Contact CPE's Technical Service and CPE will
troubleshoot any issue via phone or e-mail. If the
problem is not corrected by this method, CPE
will, at its option, authorize evaluation, repair or
replacement of the defective part or component
at a CPE Service Center. CPE will provide you
with a case number for warranty service. Please
keep it for future reference. Repairs or
replacements without prior authorization, or at
an unauthorized repair facility, will not be
covered by this warranty.
Warranty Exclusions
This warranty does not cover the following
repairs and equipment:
Normal Wear
Generators need periodic parts and service to
perform well. This warranty does not cover repair
when normal use has exhausted the life of a part
or the equipment as a whole.
Installation, Use and Maintenance
This warranty will not apply to parts and/or labor
if this generator is deemed to have been misused,
neglected, involved in an accident, abused, loaded
beyond the generators limits, modified, installed
improperly or connected incorrectly to any
electrical component. Normal maintenance such
as spark plugs, air filters, adjustments, fuel
system cleaning and obstruction due to buildup is
not covered by this warranty.
Other Exclusions
This warranty excludes:
Cosmetic defects such as paint, decals, etc.
Wear items such as filter elements, o-rings, etc.
Accessory parts such as starting batteries, and
storage covers.
Failures due to acts of God and other force
majeure events beyond the manufacturers
control.
Problems cause by parts that are not original
Champion Power Equipment parts.
This warranty does not apply to generators used
for prime power in place of a utility.
Failure to use the factory supplied LPG regulator
and hose assembly (from the tank to the panel)
will void this warranty
Limits of Implied Warranty and
Consequential Damage
Champion Power Equipment disclaims any
obligation to cover any loss of time, use of this
product, freight, or any incidental or
consequential claim by anyone from using this
generator. THIS WARRANTY IS IN LIEU OF
ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE
A unit provided as an exchange will be subject to
the warranty of the original unit. The length of
the warranty governing the exchanged unit will
remain calculated by reference to the purchase
date of the original unit.
This warranty gives you certain legal rights which
may change from state to state. Your state may
also have other rights you may be entitled to that
are not listed within this warranty.
Contact Information
Address
Champion Power Equipment, Inc.
Customer Service
10006 Santa Fe Springs Rd.
Santa Fe Springs, CA 90670
Customer Service
Mon Fri 8:30 AM 5:00 PM (PST/PDT)
Toll Free: 1-877-338-0999
Fax no.: 1-562-236-9429
Technical Service
Mon Fri 8:30 AM 5:00 PM (PST/PDT)
Toll Free: 1-877-338-0999
tech@championpowerequipment.com

Not es
Rev 70009-20080529 23