Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

GST Fire Alarm System-Catalog

Download as pdf or txt
Download as pdf or txt
You are on page 1of 72

GST is a leading fire alarm system and solution provider in China.

Its primarily engaged in


manufacturing and distribution of fre alarm systems, fre network systems and other products such
as video entry systems, electronic power meters, and building automation systems. Founded in
1993, GST has become the largest by market share and sales revenue in local market, and the
brand is awarded by China State Administration for Industry and Commerce as the only "well-known
trademark" in the industry.
UTC Fire & Security (UTCFS), a global leader in fire safety and security, with its related entities,
delivers the latest technologies on fire and electronic security throughout the world. UTCFS firstly
invested in GST by acquiring 9.9 percent of outstanding shares in 2006, and then merged the
company in July of 2009.
Integrating resources on R&D, distribution and cost control of GST, and the strength on brand,
capital and management of UTCFS, along with Chubb, Kidde, Marioff, Red Hawk, Onity and Lenel, a
comprehensive array of brands feature in the industry, UTCFS provides one-stop-shopping solutions
across the world, to enhance life quality and facilitate community development of the region.
GST manufactures over 7 million detectors and modules as well as 30,000 control panels per year,
which makes the company the largest fre detection manufacturer in China.
At the same time, our main devices are applying robotic controlled Pick & Place Machines and
Surface Mount Technology in strict conformity with ISO9001 and ISO10012.1, which is reviewed by
LPCB annually.
Over the years GST has acquired certification from various international testing bodies including
UL, LPCB, CE, PSB, SAI, HKFSD, CCC and etc. With its high quality fre & life safety products and
superior after-sales services, GST has built its reputation in the globe and solid its product distribution
in more than 80 countries and regions from Europe, Asia, Africa, Oceania to America.
About GST
Certifcation and Approval
UL Listed Fire Alarm System 1
Digital Intelligent Devices 7
Intelligent Fire Alarm Devices 12
Intelligent Fire Alarm Panels 25
Custom Panels 31
Power Supply 33
Innovation Conventional Devices 35
Conventional Fire Alarm Devices 39
Conventional Fire Alarm Panels 47
Gas Extinguishing System 51
Fire Telephone System 54
Explosion Proof Products 57
Intelligent Fire Alarm Diagram 64
Conventional Fire Alarm Diagram 65
Conventional Fire Telephone Diagram 66
UL Listed Fire Alarm Diagram 67
Contents
UL Listed
Fire Alarm System
2
UL Listed Fire Alarm System
Intelligent Fire Alarm Panel
Technical Specifcations
Single loop fre alarm control panel listed by UL
Loop capacity 230 intelligent devices
2 Style Y Notifcation Appliance Circuits (NAC)
3 fxed relay outputs for fre/fault/supervisory
Optional GMC connection
Walk Test function
Positive Alarm Sequence (PAS) per point
Programmable from panel keypad
Advanced user friendly programming software including Fuzzy Logic
AC Power supply:
120V/60Hz/2A or 220VAC 50Hz/1A
Power cable size minimum 14AWG
Operating Environment:
Temperature: 0~+ 40C
Relative Humidity: 95%
Dimension: 406mm x 666mm x 130mm
GST-M200
3
www.gst.com.cn The Intelligent Solution
Intelligent Optical Smoke Detector
Intelligent Dual Heat Detector
Technical Specifcations
Technical Specifcations
Aesthetically pleasing low profle design
8 Bit intelligent processor with A/D converter
Built in algorithm maps for false alarm rejection
Electronically addressed
Twin LED for 360 vision
Removable optical chamber for easy cleaning and maintenance
Fixed Temperature and Rate of Rise Heat Detection
Aesthetically pleasing low profle design
8 Bit intelligent processor with A/D converter
Electronically addressed
Twin LED for 360 vision
Operating voltage: 24VDC
Operating current:
Standby current: 0.8mA
Alarm current 2mA
Operating Environment:
Temperature: 0 ~ +37.8C
Relative Humidity: 95%
Dimensions: Diameter 100mm, Height 50mm
Operating voltage: 24VDC
Operating current:
Standby current: 0.8mA
Alarm current 2mA
Detection Angle: <45
Operating Environment:
Temperature: 0 ~ +37.8C
Relative Humidity: 95%
Dimensions: Diameter 100mm, Height 45mm
I-9102(UL)
I-9103(UL)
4
UL Listed Fire Alarm System
Digital Manual Call Point
Technical Specifcations
Short Circuit Isolator
Technical Specifcations
Re-settable (non-breaking glass) via special key
Advanced digital communication
Electronically addressed
Friendly installation and test
Wiring before termination
Semi-fush mount installation
Optional back-box for surface mount
Stylish pleasing design
Protection Rating: IP43
Operating Voltage: 24VDC
Operating Current:
Standby Current 0.6mA
Alarm Current 1.8mA
Operating Environment:
Temperature: -10 ~+50C
Relative Humidity: 95%
Application: Indoor use
Dimensions: 87.1 x 87.1 x 58 mm
Isolates faulty part of the loop in the event of a short circuit
Automatically reset once the fault has been cleared
LED status indicator
Operating Voltage: 24VDC
Operating Current:
Monitor Current 3mA
Action Current 15mA
Operating Environment:
Temperature: 0 ~ +49C
Relative Humidity: 93%
Dimensions: 120mm x 80mm x 39mm
Detector Base
Common Base for termination and fxing of detectors, compatible for I-9102(UL),
C-9102(UL), I-9103(UL) & C-9103(UL)
Non-electronic component
DI-M9204
C-9503
DZ-03(UL)
5
The Intelligent Solution www.gst.com.cn
I-M9300
I-M9301
Addressable Output Module
Technical Specifcations
Technical Specifcations
Addressable Input Module
Single input module suitable for monitoring switch contact of remote equipment or
connecting conventional detectors
Loop power for contact input
Used as interface with conventional detectors and additional 24VDC is required
Connection mode can be set by handhold programmer (P-9910B)
Conventional connection is monitored for cable fault
Electronically addressed
Two part plug-in construction with base mounted termination allows
easy installation and connection
Intelligent interface can be addressed and plugged in to base at time of commissioning
Single output module
Loop powered for dry contact relay output. Additional 24VDC is required for
power output
Connection mode can be set by handhold programmer (P-9910B)
Power output line is monitored for cable fault
Electronically addressed
Two part plug-in construction with base mounted termination allows
easy installation and connection
Intelligent interface can be addressed and plugged in to base at time of
commissioning
Operating Voltage: 24VDC
Operating Current:
Loop
Standby Current 1mA
Action Current 5mA
24VDC
Standby Current <10mA
Action Current <60mA
Operating Environment:
Temperature: 0~ +49C
Relative Humidity: 93%
Dimension: 120mm x 80mm x 43mm
Operating Voltage: 24VDC
Operating Current:
Loop
Standby Current 1mA
Action Current 3mA
24VDC
Standby Current <5mA
Action Current <20mA
Output capacity
Dry contact relay: 2A/24VDC
Power output: 1A/24VDC
Operating Environment:
Temperature: 0~ +49C
Relative Humidity: 93%
Dimension: 120mm x 80mm x 43mm
6
UL Listed Fire Alarm System
C-9102(UL)
C-9103(UL)
DC-M9204
Conventional Optical Smoke Detector
Technical Specifcations
Conventional Dual Heat Detector
Technical Specifcations
Aesthetically pleasing low profle design
Twin LED for 360 vision
Removable optical chamber for easy cleaning and maintenance
Operating voltage: 24VDC
Operating current:
Standby current: 0.06mA
Alarm current 30mA
Operating Environment:
Temperature: 0 ~ +37.8C
Relative Humidity: 95%
Dimensions: Diameter 100mm, Height 50mm
Fixed Temperature and Rate of Rise Heat Detection
Aesthetically pleasing low profle design
8 Bit intelligent processor with A/D converter
Twin LED for 360 vision
Operating voltage: 24VDC
Operating current:
Standby current: 0.06mA
Alarm current 30mA
Detection Angle: <45
Operating Environment:
Temperature: 0 ~ +37.8C
Relative Humidity: 95%
Dimensions: Diameter 100mm, Height 45mm
Innovative Manual Call Point
Technical Specifcations
Re-settable (non-breaking glass) via special key
Friendly installation and test
Wiring before termination
Semi-fush mount installation
Optional back-box for surface mount
Stylish pleasing design
Protection Rating: IP43
Operating Voltage: 24VDC
Operating Current:
Standby Current 0mA
Alarm Current 30mA
Operating Environment:
Temperature: -10 ~ +50C
Relative Humidity: 95%
Application: Indoor use
Dimensions: 87.1 x 87.1 x 58 mm
Protection Rating: IP43
Operating Voltage: 24VDC
Operating Current:
Standby Current 0mA
Alarm Current 30mA
Operating Environment:
Temperature: -10 ~ +50C
Relative Humidity: 95%
Application: Indoor use
Dimensions: 87.1 x 87.1 x 58 mm
Digital Intelligent
Devices
8
Digital Intelligent Devices
Digital Intelligent Optical Smoke Detector
Digital Intelligent Dual Heat Detector
Technical Specifcations
Technical Specifcations
Advanced digital communication
Built in 8 bit microprocessor
Algorithm maps for faster response and false alarm rejection
Secure and speedy communication
Intelligent drift compensation
Self diagnosis and history log
Electronic addressing
Duplicated address report
Sensing chamber for exceptional dust proof ability and LED for 360 vision
Built in remote indicator output
Unique low profle design
EN54 compliance
Built in 8 bit microprocessor
Advanced digital communication
Secure and speedy communication
Self diagnosis and history log
Electronic addressing
Duplicated address report
LED for 360 vision
Built in remote indicator output
Unique low profle design
Fixed temperature response is adjustable
EN54 compliancee
Standard: EN54-part7
Operating Voltage: 24VDC Loop
Operating Current:
Standby Current: 0.6mA
Alarm Current: 3mA
Operating Environment:
Temperature: -10 ~+50C
Relative Humidity: 95%
Field Programmable Sensitivity: 0.102dB/m ~ 0.316dB/m-3 levels
Dimensions: Diameter 100mm, Height 44.5mm
Standard: EN54-part5
Operating Voltage: 24VDC Loop
Operating Current:
Standby Current: 0.6mA
Alarm Current: 3mA
Operating Environment:
Temperature: -10 ~+50C
Relative Humidity: 95%
Detector Class: A1R, A2R, BR, A1S, A2S, BS
Dimensions: Diameter 100mm, Height 41mm
DI-9102
DI-9103
9
www.gst.com.cn The Intelligent Solution
Digital Intelligent Multi Sensor
Standard Base
Technical Specifcations
Combined all the features of DI-9102 Optical and the DI-9103 Heat detector
Advanced digital communication
Electronic addressing
LED for 360 vision
Sensing chamber for exceptional dust proof ability
Ideal alternative to Ionization detector
Low profle design
Standard base for digital DI/DC range of detectors
No electronics, safe on the time of installation
Standard: EN54-part 5 / 7
Operating Voltage: 24VDC Loop
Operating Current:
Standby Current: 0.6mA
Alarm Current: 1.5mA
Operating Environment:
Temperature: -10 ~+50C
Relative Humidity: 95%
Field Programmable Sensitivity: 0.102dB/m ~ 0.316dB/m-3 levels
Dimensions: Diameter 100mm, Height 44.5mm
DI-9101
DB-01
10
Digital Intelligent Devices
Digital Manual Call Point
Protective Flip Cover
Technical Specifcations
Re-settable (non-breaking glass) via special key
Advanced digital communication
Electronically addressing
Friendly installation and test
Wiring before termination
Semi-fush mount installation
Optional back-box for surface mount
Stylish pleasing design
LPCB Approved
Protects manual call point from accidental activation
Meets requirement of 2 step operation in consultant specifcations
Suitable for manual call points DI-9204 and DC-9204
Protection Rating: IP55
Operating Voltage: 24VDC Loop
Operating Current:
Standby Current: 0.6mA
Alarm Current: 1.8mA
Operating Environment:
Temperature: -10 ~+50C
Relative Humidity: 95%
Application: Indoor use
Dimensions: 87 x 87.5 x 58 mm, Surface Mount
87 x 87 x 23.5 mm, Flush Mount
DI-9204
D-92FC
11
www.gst.com.cn The Intelligent Solution
Weather Proof Box
Base Mount Isolator
Technical Specifcations
IP65 protective enclosure for manual call points
Large internal space enough for most types of MCP
Dimensions: 110mm x 119mm x 44.5mm
In the event of a short circuit isolates faulty parts of the loop
Automatically resetting once the fault has cleared
Compatible with digital range of detector
Can be used standalone with cover or in stead of standard base
Replace standard base of digital range detector (DB-01)
Cost effective installation without the need for additional cabling
Features as per C-9503
LED status indicator
Operating Voltage: 24VDC
Active Current: 1A
Operating Environment:
Temperature: -10 ~+50C
Relative Humidity: 95%
Application: Indoor use
Visual Indicator: Yellow LED (lit steady when alarm, off normal state)
Dimensions: Diameter 100mm, Height 37.5mm (with cover)
D-92WPB
DC-9504
Intelligent
Fire Alarm Devices
13
The Intelligent Solution www.gst.com.cn
Intelligent Optical Smoke Detector
Intelligent Dual Heat Detector
Technical Specifcations
Technical Specifcations
Aesthetically pleasing low profle design
8 Bit intelligent processor with A/D converter
Built in algorithm maps for false alarm rejection
Electronically addressed
Twin LED for 360 vision
With Remote Indicator output
Adjustable smoke detection sensitivity
Removable optical chamber for easy cleaning and maintenance
LPCB Approval
Fixed Temperature and Rate of Rise Heat Detection
Aesthetically pleasing low profle design
8 Bit intelligent processor with A/D converter
Electronically addressed
Fixed temperature response is adjustable
With Remote Indicator output
Twin LED for 360 vision
LPCB Approval
Operating Voltage: 24VDC Loop
Operating Current:
Standby Current: 0.8mA
Alarm Current: 2mA (5mA for RI)
Operating Environment:
Temperature: -10 ~+50C
Relative Humidity: 95%
Detector Class: A1R
Dimensions: Diameter 100mm, Height 50mm
Operating Voltage: 24VDC Loop
Operating Current:
Standby Current: 0.8mA
Alarm Current: 2mA (5mA for RI)
Operating Environment:
Temperature: -10 ~+50C
Relative Humidity: 95%
Dimensions: Diameter 100mm, Height 50mm
I-9102
I-9103
14
Intelligent Fire Alarm Devices
Intelligent Multi Sensor
Intelligent Ultraviolet Flame Detector
Technical Specifcations
Technical Specifcations
Standard Detector Base
Combining all the features of the I-9102 Optical and the I-9103 Dual Heat
Detector to provide the ultimate cover for life safety systems
Ideal alternative to Ionization detectors
Adjustable smoke detection sensitivity
Sensitive Ultraviolet sensor that detects the UV rays produced by a fame
Aesthetically pleasing Low profle design
Dust / corrosion / humidity resistant
Electronically addressed
Standard calibration set to detect a 3cm fame at 6 metres
Effective range 12 metres
Operating Voltage: 24VDC Loop
Operating Current:
Standby Current: 0.6mA
Alarm Current: 1.8mA
Operating Environment:
Temperature: -10 ~+50C
Relative Humidity: 95%
Field Programmable Sensitivity: 0.1dB/m~0.56dB/m-3 levels
Dimensions: Diameter 100mm, Height 50mm
Operating Voltage: 24VDC Loop
Operating Current:
Standby Current: 2mA
Alarm Current: 2.5mA
Operating Environment:
Temperature: -10 ~+50C
Relative Humidity: 95%
Detection Angle: 80
Dimensions: Diameter 100mm, Height 41mm
Base for termination and fxing of detectors
Non-electronic component
Common base for I-9101/1/2/3/4
I-9101
I-9104
DZ-03
15
The Intelligent Solution www.gst.com.cn
Intelligent Refective Beam Detector
Technical Specifcations
Range 8 -100 Metres
2 selectable levels of sensitivity adjustment
Compatible with conventional Panel
Ideal for Atriums, Warehouses, Shopping Centres, Airport Terminals, etc.
Simple and cost effective installation of transmitter and refective honey comb mirror
Quick and easy to set up and align with visual green LED indication that
fashes faster or slower subject to signal strength. Replace the cover and the
detector will self calibrate to the required level.
LPCB Approved
Operating voltage: 24VDC Loop, 24VDC Power Supply
Operating Current:
Detection Range: Length from 8 to 100 metres, with 7 metres in both sides
Wiring: Non-polarized two-core 24VDC
Non-polarized two-core detection loop
Operating Environment:
Temperature: -10 ~ +50C
Relative Humidity: 95%
Dimensions: 206mm 95mm 95mm
Used as addressable detector Used as conventional detector
Power Current:
Commission Current: 20mA
Standby Current: 8mA
Alarm Current: 12mA
Loop Current:
Standby Current: 0.6mA
Alarm Current: 2mA
I-9105R
Intelligent Linear Cable Heat Detector
Technical Specifcations
Fixed temperature linear cable heat detector
Typically used to detect overheat in high power cable trays
Confgurable with single or dual detection cable
Each detection cable - C-9106 up to 500 meters cable length
Alarm condition shows cable distance location on fre panel
Test button on the End of Line Unit - P-9106
Electronically addressed
Operation Voltage: 24V Loop
Operation Current:
Standy Current: 3mA
Alarm Current: 5mA
Alarm temperature: optional 85C or 105C (specifed by cable type).
Operating Environment:
Temperature: -10 ~+80C
Relative humidity: 95%
Dimensions:
Interface 162mm x 200mm x 80mm
End of Line Unit 120mm x 80mm x 40mm
I-9106
Power Current:
Commission Current: 20mA
Standby Current: 12mA
Alarm Current: 22mA
16
Intelligent Fire Alarm Devices
Addressable Combustible Gas Detector
Addressable CO Gas Detector
Technical Specifcations
Technical Specifcations
Available for LPG, Natural Gas and Coal Gas (please specify at time of order)
Built-in relay contacts for control of Gas Valves / Extract etc
Built-in sounder with 2 stage alarm
Manual reset and control (on/off) of relay contacts
Electronically addressed
Wall-mount (LPG) or ceiling mount (Natural Gas and Coal Gas)
Addressable CO detector suitable for car park and garage use
Loop powered, maximum 80 units per loop
Two stage alarm for two preset alarm levels
Long life sensor, easy maintenance
Electronically addressed
Mounting plate provided
Operating Voltage: 24V Loop, 24VDC Power Supply
Operating Consumption (power supply): 1.5Watt
Alarm Level: Pre-alarm: 12%LEL
Urgent Alarm: 23%LEL
Output: K1/K2, N/O contact, 3A/220VAC, active when pre-alarm
V1/V2, 24VDC Pulse
Operating Environment:
Temperature: -10 ~+50C
Relative Humidity: 95%
Wiring: Non-polarized 2-core for loop
Non-polarized 2-core for 24VDC power supply
Dimensions: 121mm x 87mm x 57mm
Operating Voltage: 24VDC
Operating Current:
Standby Current 2mA
Action Current 2.5mA
Alarm level
Level 1: 2510 ppm
Level 2: 2510 ppm
Sensor life: >3 years
Operating Environment:
Temperature: -20~ +55C
Relative Humidity: 95%
Dimension: 109mm x 109mm x 55mm
I-9603(CO)
I-9602LW/LPG
I-9602LW/NG
I-9602LW/CG
17
The Intelligent Solution www.gst.com.cn
Remote Indicator
Technical Specifcations
Technical Specifcations
Intelligent Remote Indicator
Can be program linked to any single or group of devices
High intensity fashing LED in alarm condition
Electronically addressed
Remote indicator for direct connection to detector via remote indicator terminals
Compatible with Digital, Intelligent, Innovation and Conventional series Optical
Smoke detectors and Dual Heat Detectors.
Operating Voltage: 2.0 - 3.0VDC
Operating Current: <5mA
Operating Environment:
Temperature: -10 ~+50C
Relative Humidity: 95%
Dimensions: 64.5mm x 64.5mm x 31.4mm
Operating Voltage: 24VDC Loop
Operating Current:
Monitoring Current: 0.8mA
Action Current: 16mA
Operating Environment:
Temperature: -10~+ 50C
Relative Humidity: 95%
Dimensions: 120mm x 80mm x 49mm
I-9314
C-9314P
18
Intelligent Fire Alarm Devices
Addressable Sounder And Strobe
Technical Specifcations
Technical Specifcations
Addressable Sounder Beacon
Addressable combined fashing high intensity LED beacon and sounder
Two part plug-in construction with base mounted termination allowing
easy installation and connection
Electronically addressed
Two parts construction with base mounted termination allows easy installation
Evacuate only or Alert/Evacuate mode can be set through handheld programmer
Remote start input can be used to co-operation with other systems
Strobe provided by high intensity LED cluster
Electronically addressed
LPCB Approved
Operating Voltage: 24VDC Loop, 24VDC Power Supply
Operating Current:
Loop: Standby Current 0.8mA, Alarm Current 6.0mA
Power Supply: Standby Current 10mA, Alarm Current 160mA
Alarm Volume (SPL): 95dB @1 Metre
Wiring: Non-polarized 2-core for loop
Non-polarized 2-core for power supply
Operating Environment:
Temperature: -10~+ 50C
Relative Humidity: 95%
Dimension: 144mm x 90mm x 57mm
Operation Voltage: 24VDC Loop, 24VDC Power Supply
Operating Current:
Loop: Standby Current 1mA, Alarm Current 3mA
Power Supply: Standby Current 3mA, Alarm Current 65mA
Sounder Output: 94dB @ 1 Metre
Wiring: Non-polarized 2-core for loop
Non-polarized 2-core for power supply
Operating Environment:
Temperature: -10~+ 50C
Relative Humidity: 95%
Dimension: Diameter 110mm, Height 97.5mm
I-9401
I-9403
19
The Intelligent Solution www.gst.com.cn
Deep Base
Technical Specifcations
Addressable Sounder
Identical in appearance and features to the I-9403 but without the strobe element
Optional deep base for Sounder and Strobe (I-9403 / I-9404 / I-9407)
For surface mount cable entry
Operation Voltage: 24VDC Loop, 24VDC Power Supply
Operating Current:
Loop: Standby Current 1mA, Alarm Current 5mA
Power Supply: Standby Current 3mA, Alarm Current 35mA
Sounder Output: 94dB @ 1 Metre
Wiring: Non-polarized 2-core for loop
Non-polarized 2-core for power supply
Operating Environment:
Temperature: -10~+ 50C
Relative Humidity: 95%
Dimension: Diameter 110mm, Height 97.5mm I-9404
C-94DB
20
Intelligent Fire Alarm Devices
Addressable Sounder And Strobe Loop Powered
Technical Specifcations
Technical Specifcations
Addressable Sounder Beacon Base
Loop powered no additional cabling required
Sound level 92dB/1m
16 programmable tones
Early notifcation setting for sleeping areas
Sandwich design
Electronically addressed
Can utilize same address as detector
Easy plus installation
Two parts construction with base mounted termination allows easy installation
Evacuate only or Alert/Evacuate mode can be set through handheld programmer
Remote start input can be used to co-operation with other systems
Strobe provided by high intensity LED cluster
Electronically addressed
Operating Voltage: 24VDC Loop
Operating Current:
Standby Current: 1mA
Action Current: 8-15mA
Sound Output (SPL): 92dB @1 Metre
Operating Environment:
Temperature -10 ~ +50C
Relative Humidity 95%
Dimension: Diameter 150mm, Height 42mm
Operation Voltage: 24VDC Loop
Operating Current:
Loop: Standby Current 1mA, Alarm Current 10mA
Sounder Output: 94dB @ 1 Metre
Wiring: Non-polarized 2-core
Operating Environment:
Temperature: -10~+ 50C
Relative Humidity: 95%
Dimension: Diameter 110mm, Height 97.5mm
I-9406
I-9407
21
The Intelligent Solution www.gst.com.cn
Intelligent Single Input /Output Module
Technical Specifcations
Technical Specifcations
Addressable Input Module
Monitor switch contacts of remote equipment
Loop powered
Input programmable for NO or NC contacts (Programmable via P-9910B
handheld programmer)
Two part plug-in construction with base mounted termination allows
easy installation and connection
Intelligent interface can be addressed and plugged in to base at time
of commissioning
Electronically addressed
LPCB Approved
Addressable I/O with 24V / 3Amp relay output contacts
Input can be confgured as NO / NC or self confrmation of output
(Programmable via P-9910 handheld programmer)
Two part plug-in construction with base mounted termination allows easy
installation and connection
Intelligent interface can be addressed and plugged in to base at time of
commissioning
Electronically addressed
LPCB Approved
Operating Voltage: 24VDC Loop
Operating Current:
Standby Current: 1mA
Action Current: 5mA
Operating Environment:
Temperature: 0~+ 49C
Relative Humidity: 93%
Dimension: 120mm x 80mm x 39mm
Operating Voltage: 24VDC Loop, 24VDC Power Supply
Operating Current:
Loop: Standby Current 1mA, Alarm Current 3mA
Power Supply: Standby Current 2mA, Alarm Current 15mA
Wiring: Non-polarized two-core for loop
Non-polarized two-core for 24VDC power supply
Operating Environment:
Temperature: 0~+ 49C
Relative Humidity: 93%
Dimension: 120 mm x 80mm x 39mm
I-9301
I-9300
22
Intelligent Fire Alarm Devices
Addressable Double I/O Module
Technical Specifcations
Technical Specifcations
Intelligent Single Input /Output Module Loop Powered
Addressable I/O with 24V /3Amp relay output contacts
Input can be confgured as NO / NC or self confrmation of output
(Programmable via P-9910 handheld programmer)
Two part plug-in construction with base mounted termination allows easy
installation and connection
Intelligent interface can be addressed and plugged into base at time
of commissioning
Electronically addressed
Addressable I/O with 24V / 3Amp relay output contacts with 2 independent circuits
Input can be confgured as NO / NC or self confrmation of output (Programmable
via P-9910 handheld programmer)
Two part plug-in construction with base mounted termination allows easy
installation and connection
Intelligent interface can be addressed and plugged in to base at time of
commissioning
Electronically addressed
Operating Voltage: 24VDC Loop
Operating Current:
Standby Current: 1mA
Action Current: 5mA
Wiring: Non-polarized two-core for loop
Operating Environment:
Temperature: -10~+ 50C
Relative Humidity: 95%
Dimension: 120 mm x 80mm x 40mm
Operating Voltage: 24VDC Loop, 24VDC Power Supply
Operating Current:
Loop: Standby Current 1mA, Alarm Current 4mA
Power Supply: Standby Current 4mA, Alarm Current 15mA
Wiring: Non-polarized two-core for loop
Non-polarized two-core for 24VDC power supply
Operating Environment:
Temperature: -10~+ 50C
Relative Humidity: 95%
Dimension: 120 mm x 80mm x 43mm
DI-9301
I-9303
23
The Intelligent Solution www.gst.com.cn
Addressable Multi-channel Interface
Technical Specifcations
Technical Specifcations
Addressable Sounder Circuit Module
Cost effective (cable saving) distributed addressable control of conventional
sounder circuits
Connects to conventional polarised 24VDC sounders/strobes
Utilizes two addresses (one for Alert and one for Evacuate Control)
Two part plug-in construction with base mounted termination allows easy
installation and connection
Electronically addressed
Cable monitoring for fault of short circuit and open circuit
Interface board for plant monitoring and control
Multi channel integrated for savings installation cost
Input cable fault monitored for short circuit and open circuit
Ideal for monitoring of pump rooms
Electronically addressed
Operating Voltage: 24VDC Loop, 24VDC Power Supply
Operating Current:
Loop: Standby Current 1.5mA, Alarm Current 4mA
Power Supply: Standby Current 10mA,
Alarm Current 500mA max
End of Line: 4.7k
Operating Environment:
Temperature: -10~+ 50C
Relative Humidity: 95%
Dimensions: 120mm x 80mm x 43mm
Operating Voltage: 24VDC Loop, 24VDC Power Supply
Operating Current:
Loop: Standby Current 1.5mA, Alarm Current 3mA
Power Supply: Standby Current 50mA, Alarm Current 100mA
Capability: 1~16 input channels
2 dry contact output channels
Rate of Relay: 2A/220VAC
End of Line: 4.7k resistor
Action Resistance: 470~680
Operating Environment:
Temperature: -10 ~ +50C
Relative Humidity: 95%
Dimension: 200mm x 100mm x 20mm
DI-9309
I-9308
24
Intelligent Fire Alarm Devices
Short Circuit Isolator
Technical Specifcations
Technical Specifcations
Addressable Zone Monitor Unit
Interfaces with conventional fre detection equipment/panels etc
Can connect up to 15 detectors with Active EOL or up to 25 detectors
with Resistor EOL
Ideal for integrating Sprinkler Zone Valve and Flow Switches
Electronically addressed
Isolates faulty part of the loop in the event of a short circuit
Automatically reset once the fault has been cleared
LED status indicator
LPCB Approved
Operating Voltage: 24VDC Loop, 24VDC Power Supply
Operating Current (loop):
Loop: Standby Current 0.5mA, Alarm Current 5mA
Power Supply: Standby Current 10mA, Alarm Current 60mA
Capability: 15 conventional detectors
End of Line: 4.7k resistor or AEOL
Action Resistance: 470~680
Operating Environment:
Temperature: -10~+ 50C
Relative Humidity: 95%
Dimension: 120mm x 80mm x 43mm
Operating Voltage: 24VDC
Operating Current:
Monitor Current: 3mA
Action Current: 15mA
Operating Environment:
Temperature: 0~+ 49C
Relative Humidity: 93%
Dimensions: 120mm x 80mm x 39mm
Base Mount Short Circuit Isolator
Replaces standard detector base (DZ-03)
Cost effective installation without the need for additional cabling
Features as per C-9503
Base Type: Diameter 103mm, Height 20mm
I-9319
C-9503
C-9504
Intelligent
Fire Alarm Panels
26
Intelligent Fire Alarm Panels
Addressable Mini Fire Panel
Single loop addressable panel
Can connect up to 128 addressable devices
8 zone fre and fault indication with consumer defnable label
Self confgurable via panel keyboard
Easy commissioning making the GST100 an ideal product for electrical installers
Technical Specifcations
Power Supply: 230VAC 50/60Hz
Operating Environment:
Temperature: 0~+ 40C
Relative Humidity: 95%
Dimension: 210mm x 300mm x 91mm
Intelligent Fire Alarm Control Panel
Technical Specifcations
Approved by LPCB
Two loop addressable fre detection panel packed with features not usually associated
with smaller systems, providing a high quality solution at exceptionally good value.
Loop capacity 477 intelligent devices
30 logical confgurable zones
PAS and Acknowledge Function
Dirty Detector Reporting
One Man Test Function
Graphical LCD Display
Zone indication and manual intervention panel
Net-workable with all GST intelligent fre panels
Programmable from PC
Built-in RS485 repeater output (Maximum 10 repeaters)
Optional GMC system
Optional Firemans Control Panel
Optional Panel Printer
Advanced user friendly programming software including Fuzzy Logic
Standard: EN54 Part 2/4
Approvals: LPCB, CE
Main Input Voltage: 220 10% VAC 50/60 Hz
Input Current Rating: 0.500A
System Operating Voltage: 24 VDC Nominal (20-27 VDC)
Loop Capacity: Loop 1:235 ;loop 2:242(Address)
Outputs (3):
Fire Alarm Output: 500mA /24Vdc/NO-NC
F.P.E. Output: 500mA /24Vdc/NO-NC
Sounder Circuit Output: 500mA /24Vdc/NO-NC
Dimension: (HWD)
Outer: 580 x 420 x 30 mm
Inner: 550 x 393 x 173 mm
GST100
GST200-2
27
The Intelligent Solution www.gst.com.cn
Technical Specifcations
Intelligent Fire Alarm Control Panel
Approved by LPCB
8 x Loops (242) capacity (1936) addressable points
Maximum 10 Loops Standalone
Modular constructed for future expansion
40 x15 lines Colour Graphical LCD Display.
Up to 999 programmable zones and 140 zone indication
Auto Programming Day and Night Mode
Enable and Disable function
PAS and Acknowledge Function
Dirty Detector Reporting
Duplicate Address Checking
Device Mismatch
Walk Test Function with optional silent mode
Can edit device detailed and programmed
Programmable form PC or Panel
History record-999 fre incident only and 999 event capacity in non-volatile
memory Fully simulation of Cause and Effect
Advanced user friendly programming software including Fuzzy Logic.
Networked with all GST Intelligent Fire panels up to 64 nodes,
Optical Fiber Optic Network Interface
Optional GST GMC graphic station
Optional RS 485 mimic and repeater up to 64
Optional GST GMC graphic station
Built in Fire Alarm, FPE, Fault and Alarm Router output
Panel Printer included
Built in Battery charger
Standard: EN54 Part 2/4
Approvals: LPCB
Main Input Voltage: 220 10% VAC 50/60 Hz
Input Current Rating: 1Amphere
System Operating Voltage: 24 VDC Nominal (20-27 VDC)
Loop Capacity: Loop 1-10 :242- Address per loop
Zone Capacity: 999 Zones programmable
Outputs (3):
Fire Routing: 200mA /24Vdc/4.7K EOLR
F.P.E. Output: 500mA /24Vdc/4.7K EOLR
Sounder Circuit Output: 1A /24Vdc/4.7K EOLR
Dimension: (HWD)
Outer: 850 x 484 x 185 mm
Inner: 804 x 440 x 150 mm
GST-IFP8
28
Intelligent Fire Alarm Panels
Intelligent Fire Alarm Control Panel
Intelligent Modular 1-20 Loop Fire Alarm Control Panel
Technical Specifcations
Technical Specifcations
Addressable fre detection with integrated controls providing the perfect solution
for all medium sized projects
Loop capacity 242 intelligent devices
40 12 characters Large Graphical LCD Display
60 zone indication and manual intervention panel
Zone indication and manual intervention panel
Net-workable with all GST fre panels
Programmable from PC
Built-in RS485 repeater output (Maximum 64 repeaters)
Built-in Gas Extinguishing Control
Integrated Security Alarm Facilities
Optional Firemans Control Panel
Panel Printer included
Optional GMC system
Advanced user friendly programming software including Fuzzy Logic
GST5000/2 Two loop panel can connect up to 480 devices
GST5000/4 Four loop panel can connect up to 750 devices
Fully modular and expandable fre command system, with multi loop and full
integration with GST Voice Alarm System and Fire Telephone System, housed
im either rack or console type housing provides the periect solution for all
medium to large systems.
Loop capacity 240 intelligent devices (up to 4800 addressable points)
40 12 characters Large Graphical LCD Display
64 zone indication and manual intervention control expandable to 254
zone and plant overrides
Net-workable with all GST fre panels
Programmable from PC
Built-in Gas Extinguishing Control
Integrated Security Alarm Facilities
Optional Firemans Control Panel
Panel Printer included
Optional Colour Graphics
Advanced user friendly programming software including Fuzzy Logic
Total integration with GST addressable Voice Alarm sysrems
Order additional loop cards separately GST5000LC
Power supply:230VAC 50/60Hz
Operating Environment:
Temperature: 0~+ 40C
Relative Humidity: 95%
Dimension: 506mm x 756mm x 170mm
Power supply:230VAC 50/60Hz
Operating Environment:
Temperature: 0~+ 40C
Relative Humidity: 95%
Dimension: 580mm x 520mm x 1873mm (Rack type enclocure)
1080mm x 1113mm x 1350mm (2 bay console)
GST5000W/2or4
GST5000/20/C
GST5000/20/R
29
The Intelligent Solution www.gst.com.cn
Firemans Control Panel
Components for FCP-014
Handheld Programmer
Portable programming tool for addressing and testing of intelligent devices
Programs all loop devices (1-242)
Programming of I2C protocol devices like Refective Beam Detector and
GST8903 Mimic Panel
Interrogates device for Condition - Manufacturing Batch Number - Date of
manufacture alarm sensitivity
Re-program facility enables adjustment to alarm threshold of detectors
Able to switch on or off the rate of rise function of dual heat detector (I-9103)
Adjusts input modules to accept N/C or N/O contacts.
Dimensions: 164mm x 64mm x 24mm
CPU controlled switches with addressable and direct outputs
Ideal for controlling of smoke vents, AHUs, exhaust fans, smoke curtains, etc.
Single confrmation
Overides cause and effects
For building fremans switch on wall mount panels
Ideal for controlling of AHUs, exhaust fans, smoke curtains, etc.
Overides cause and effects
P-9910B
GST-FCP14
FCP-M01
FCP-Z02
30
Intelligent Fire Alarm Panels
Technical Specifcations
Technical Specifcations
LCD Passive Repeater Panel
Network Repeater Panel
Graphic Monitor Centre
Aesthetically pleasing design with large LCD display
Compatible with all GST intelligent fre alarm panels
Back lit LCD displaying all fre information
Local sounder mute and scroll alarms buttons
Two part plug-in construction with base mounted termination allows
easy installation and connection
Repeater can be plugged in to base at time of commissioning
Provides remote control of system
Password protect access levels
Flush-mount or Surface-mount structure
Functional control of network panels
Colour graphic control and display system, providing a complete
window on the fre detection systems and ancillary equipment
Compatible with all GST intelligent fre panels
Multi-level password control for convenient system management
PC not included
Operation Voltage: 24VDC
Standby Power: 2W
Maximum Power: 5W
Operation Environment:
Temperature: 0~+ 40C
Relative Humidity: 95%
Dimension: 234mm x 104mm x 35mm
Operation Voltage: 24VDC
Standby Power: 2W
Maximum Power: 5W
Operation Environment:
Temperature 0~+ 40C
Relative Humidity 95%
Dimension: 390mm x 270mm x 100mm
GST-NRP01
GSTGMC
GST852RP
Custom Panels
32
Intelligent Fire Alarm Panels
Technical Specifcations
Technical Specifcations
Graphic Mimic Panel
Sprinkler Monitoring and Indication Panel
Graphic repeater panel for GST fre alarm systems, compatible with all
GST intelligent fre alarm panels
Up to 100 LED indication points
Custom Graphical layout to project requirement.
Electronically Programmed by handheld programmer
Programmable to display zones or individual device
Programmable to indicate Fire and Fault conditions
A3, A2, A1 and A0 sizes
Custom indication panel fully integrated with fre alarm system
Zonal valve, fow switch, pump status and water tank level etc indicated clearly
by individual LEDs
Front facial layout custom manufactured according to project requirements
Riser diagram layout available
Operation Voltage: 24VDC
Standby Current: 25mA
Active Current: 100mA
LED Capacity: 100
Operation Environment:
Temperature: 0~+ 40C
Relative Humidity: 0 ~ 95%
Operation Voltage: 24VDC
Standby Current: 25mA
Active Current: 100mA
LED Capacity: 100
Operation Environment:
Temperature: 0~+ 40C
Relative Humidity: 0 ~ 95%
GST8903
GST-SIP
Power Supply
34
Power Supply
Power Supply Unit
Power Supply Unit
24 volt DC intelligent PSU, 5 ampere and 10 ampere version
Digital display showing output voltage and load current
Fully monitored with output protection
Addressable intelligence for monitoring and reporting to main fre alarm panel
(PSU24-5A & PSU24-10A)
24 volt DC PSUs for heavy load applications
Battery capacity monitored and displayed
Boost charge function available
Fully monitored
Input and output protection
DC power ratings: 15A, 30A, 45A and 60A models
PSU24-5
PSU24-5A
PSU24-10
PSU24-10A
PSU24-15
PSU24-30
PSU24-45
PSU24-60
The Innovation range of detectors are setting a new standard in conventional detection by utilizing
our expertise in intelligent fre detection. We now offer unrivaled features such as:
Linear Drift Compensation
Algorithm maps for faster response and false alarm rejection
Blinking LED
Conventional
Devices
Innovation
36
Innovation Conventional Devices
Innovative Conventional Optical Smoke Detector
Algorithm maps for faster response and false alarm rejection
Intelligent drift compensation
Sensing chamber for exceptional dust proof ability and LED for 360 vision
Built in remote indicator output
Unique low profle design
EN54 compliance
Technical Specifcations
Technical Specifcations
Innovative Conventional Dual Heat Detector
Combined fxed temperature and rate of rise heat detection
LED for 360 vision
Built in remote indicator output
Unique low profle design
EN54 compliance
Standard: EN54-part5
Operating Voltage: 24VDC
Operating Current:
Standby Current: 0.06mA
Alarm Current: 55mA
Operating Environment:
Temperature: -10~+ 50C
Relative Humidity: 95%
Detector Class: A1R, A2R, BR, A1S, A2S, BS
Dimensions: Diameter 100mm, Height 41mm
Standard: EN54-part7
Operating Voltage: 24VDC
Operating Current:
Standby Current: 0.06mA
Alarm Current: 55mA
Operating Environment:
Temperature: -10~+ 50C
Relative Humidity: 95%
Dimensions: Diameter 100mm; Height 44.5mm
DC-9102
DC-9103
37
The Intelligent Solution www.gst.com.cn
Innovative Multi Sensor
Combined all the features of the DC-9102 Optical and the DC-9103 Heat detector
LED for 360 vision
Sensing chamber for exceptional dust proof ability
Ideal alternative to Ionization detector
Low profle design
Active End of Line
Technical Specifcations
Diode Base
Diode base for DC range of conventional detectors
For use with DP-9907 Active End of Line
Active End of Line for conventional fre detection zones
It can be used as conventional detector base or work independent with a cover
Provides detector removal indication while still enabling alarms down stream
of the missing device to be detected
Compatible with all GST conventional panels
Compatible with addressable zone interface I-9319
Standard: EN54-part 5, part 6 and part 7
Operating Voltage: 24VDC
Operating Current:
Standby Current: 0.06mA
Alarm Current: 55mA
Operating Environment:
Temperature: -10~+ 50C
Relative Humidity: 95%
Dimensions: Diameter 100mm, Height 44.5mm
DC-9101
DB-01D
DP-9907
38
Innovation Conventional Devices
Innovative Conventional Manual Call Point
Re-settable (non-breaking glass) via special key
Easy 1st and 2nd fx installation
Semi-fush or surface mount installation
Optional back-box for surface mount
Pleasing style design
LPCB Approved
Technical Specifcations
Weather Proof Box
Protective Flip Cover
IP65 protective enclosure for manual call points
Large internal space enough for most types of MCP
Dimensions: 110mm x 119mm x 44.5mm
Protects manual call point from accidental activation
Meets requirement of 2 step operation in consultant specifcations
Suitable for manual call points DI-9204 and DC-9204
Protection Rating: IP55
Operating Voltage: 24VDC
Operating Current:
Standby Current: 0
Alarm Current: 30mA
Operating Environment:
Temperature: -10~+ 50C
Relative Humidity: 95%
Contact Resistance: 100m
Application: Indoor use
Dimensions: 87 x 87 x 58 mm, Surface Mount
87 x 87 x 23.5 mm, Recess Mount
DC-9204
D-92FC
D-92WPB
Conventional
Fire Alarm Devices
40
Conventional Fire Alarm Devices
Conventional Optical Smoke Detector
Aesthetically pleasing low profle design
Twin LED for 360 vision
Removable optical chamber for easy cleaning and maintenance
With remote indicator output
LPCB Approval
Technical Specifcations
Technical Specifcations
Conventional Dual Heat Detector
Fixed Temperature and Rate of Rise Heat Detection
Aesthetically pleasing low profle design
8 bit intelligent processor
Twin LED for 360o vision
With remote indicator output
LPCB Approval
Standard: EN54-part5
Operating Voltage: 24VDC
Operating Current:
Standby Current: 0.06mA
Alarm Current: 30mA
Operating Environment:
Temperature: -10~+50C
Relative Humidity: 95%
Dimensions: Diameter 100mm, Height 50mm
Standard: EN54-part7
Operating Voltage: 24VDC
Operating Current:
Standby Current: 0.06mA
Alarm Current: 30mA
Operating Environment:
Temperature: -10~+50C
Relative Humidity: 95%
Dimensions: Diameter 100mm, Height 50mm
C-9102
C-9103
41
The Intelligent Solution www.gst.com.cn
Conventional Multi Sensor
Combined all the features of the C-9102 Optical and the C-9103 Heat detector
LED for 360 vision
Sensing chamber for exceptional dust proof ability
Ideal alternative to Ionization detector
Low profle design
Technical Specifcations
Technical Specifcations
Conventional Ultraviolet Flame Detector
Ultraviolet Sensor that detects the UV rays emitted by a fame
Aesthetically pleasing low profle design
Dust / corrosion / humidity resistant
Standard calibration set to detect a 3cm fame at 6 metres
Effective range 12 metres
Operating Voltage: 24VDC
Operating Current:
Standby Current: 1.2mA
Alarm Current: 30mA
Operating Environment:
Temperature: -10~+50C
Relative Humidity: 95%
Detection Angle: 80
Dimensions: Diameter 100mm, Height 41mm
Standard: EN54-part 5, part 6 and part 7
Operating Voltage: 24VDC
Operating Current:
Standby Current: 0.06mA
Alarm Current: 30mA
Operating Environment:
Temperature: -10~+ 50C
Relative Humidity: 95%
Field Programmable Sensitivity: 0.102dB/m ~ 0.316B/m-3 levels
Dimensions: Diameter 100mm, Height 44.5mm
C-9101
C-9104
42
Conventional Fire Alarm Devices
4-wire Conventional Smoke Detector
Two of output contacts, open circuit when operating; contacts closed
and self-lock when alarming
New scattering technology
Unique labyrinth design protect against insect, dust, light infltration
Technical Specifcations
Technical Specifcations
4-wire Conventional Heat Detector
Two of output contacts, open circuit when operating; contacts closed
and self-lock when alarming
Built-in single chip microcomputer for real time data sampling and processing
Fixed temperature alarm
Operating Voltage: 12VDC
Operating Current:
Standby Current: 1mA
Alarm Current: 20mA
Operating Environment:
Temperature: -10~+50C
Relative Humidity: 95%
Dimensions: Diameter 100mm, Height 58mm
Operating Voltage: 12VDC
Operating Current:
Standby Current: 1mA
Alarm Current: 20mA
Operating Environment:
Temperature: -10~+50C
Relative Humidity: 95%
Dimensions: Diameter 100mm, Height 56mm
R-6601
R-6602
43
The Intelligent Solution www.gst.com.cn
Smoke Alarm (Battery Optical Smoke Detector)
Self contained optical smoke detector and alarm sounder
Easy installation
Test/Reset Button
Low battery indication
Battery removal will inhibit cover from closing (as per UL standards)
Low sensitivity alert
Connection port to link up to 30 detectors in a single system
Output to interface with other security equipment
Technical Specifcations
Standard Detector Base
Diode Base
Fixing and terminating of conventional detectors with directional gaps
Compatible with GST conventional detectors using 4.7k, resistor
end of line (EOLR)
Common base for C-9101 / 2 / 3 / 4
Diode base version for conventional detectors utilising P-9907
active end of line (AEOL)
Common base for C-9101 / 2 / 3 / 4
Power Supply: PP3 DC9V battery, lasting 1+ year
Sounder Output: 80dB @ 1 Metre
Operating Environment:
Temperature: -10~+ 50C
Relative Humidity: 95%
Dimension: Diameter 140mm, Height 54mm (with base)
S-9102
DZ-03
DZ-03D
44
Conventional Fire Alarm Devices
Conventional Combustible Gas Detector
Available for LPG, Natural Gas and Coal Gas (please specify at time of order)
Built-in relay contacts for control of Gas Valves / Extract etc
Built-in sounder with 2 stage alarm
Manual reset and control (on/off) of relay contacts
Technical Specifcations
Technical Specifcations
Conventional Manual Call Point
Compatible with latest EN standards
Non-breaking re-settable glass (via special key)
Two part plug-in construction with base mounted termination allows easy
installation and connection
Operating Voltage: 24VDC
Operating Current:
Standby Current: 0
Alarm Current: 30mA
N/O Output Contact: Rating 60VDC, 0.1A
Contact Resistance 100m
Operating Environment:
Temperature: -10~+50C
Relative Humidity: 95%
Dimensions: 95mm x 98mm x 40mm
Operating Voltage: 220VAC
Operating Consumption: 3Watt
Alarm Level: Pre-alarm 12%LEL
Urgent Alarm 23%LEL
Output: K1/K2, N/O contact, 3A/220VAC, active when pre-alarm
V1/V2, 12VDC Pulse
Operating Environment:
Temperature: -10~+50C
Relative Humidity: 95%
Wiring: 2-core AC power supply
C-9602LW-LPG
C-9602LW-NG
C-9602LW-CG
C-9202
45
The Intelligent Solution www.gst.com.cn
Conventional Sounder Beacon
Conventional Sounder and Strobe
Conventional combined fashing high intensity LED beacon and sounder
Two part plug-in construction with base mounted termination allowing easy
installation and connection
Two parts construction with base mounted termination allows easy installation
Strobe provided by high intensity LED cluster
Technical Specifcations
Technical Specifcations
Operating Voltage: 24VDC
Operating Current:
Standby Current: 0mA
Alarm Current: 160mA
Alarm Volume (SPL): 95dB @1 Metre
Wiring: 2-core polarized
Operating Environment:
Temperature: -10~+50C
Relative Humidity: 95%
Dimension: 144mm x 90mm x 57mm
Operation Voltage: 24VDC
Operating Current:
Standby Current: 0mA
Alarm Current: 50mA
Sounder Output: 94dB @ 1 Metre
Wiring: 2-core polarized
Operating Environment:
Temperature: -10~+50C
Relative Humidity: 95%
Dimension: Diameter 110mm, Height 97.5mm
C-9401
C-9403
46
Conventional Fire Alarm Devices
Conventional Sounder
Identical in appearance and features to the C-9403 but without the
strobe element
Technical Specifcations
Deep Base
Optional deep base for Sounder and Strobe (C-9403 / C-9404)
For surface mount cable entry
Operation Voltage: 24VDC
Operating Current:
Standby Current: 0mA
Alarm Current: 35mA
Sounder Output: 94dB @ 1 Metre
Wiring: 2-core polarized
Operating Environment:
Temperature: -10~+50C
Relative Humidity: 95%
Dimension: Diameter 110mm, Height 97.5mm
C-9404
C-94DB
Conventional
Fire Alarm Panels
48
Conventional Fire Alarm Panels
Conventional Fire Alarm Panels
LPCB Approved
1/2/4/8/16 zone conventional fre alarm panels
Both End of Line Resister and Active End of Line can be used
Day/night mode selected (not valid for GST101&GST102)
Zone isolate control
Key-control evacuation over-ride
Repeater output available
Fire alarm output for remote alarm
Class change terminal for remote control
Active EOL enables multiple alarm reporting from same zone
Active EOL max 15 fre detectors and infnite manual buttons each zone
Resistor EOL up to 25 detectors and infnite manual buttons each zone
Optional relay output board
Technical Specifcations
Standard: EN54 Part 2 / 4
Approvals: LPCB , CE
Power Supply: 230VAC 50/60Hz
Operating Environment:
Temperature: 0~+40C
Relative Humidity: 95%
Dimension 210mm x297mm x 90mm
GST101
GST102
GST104
GST108
GST116
49
The Intelligent Solution www.gst.com.cn
Conventional Fire Alarm Control Panel
Single zone conventional fre panel
Compact design
Suitable for both Active and resistor end of line monitoring.
Similar features as standard GST101
Accessory of conventional fre alarm control panels
Relay board for additional fre and fault signal outputs
Part Number RB102 RB104 RB108 RB116
Compatible Panel GST102 GST104 GST108 GST116
Contact Capability 24VDC/1A 24VDC/1A 24VDC/1A 24VDC/1A
Relay Board
Fire Output 2 Fire Output 4 Fire Output 8 Fire Output 16
Fault Output 2 Fault Output 4 Fault Output 8 Fault Output 16
Outputs
GST101S
RB1XX Series
50
Conventional Fire Alarm Panels
Active End of Line
Active End of Line for conventional fre detection zones
It can be used as conventional detector base or work independent with a cover
Provides detector removal indication while still enabling alarms down stream
of the missing device to be detected
Compatible with all GST conventional panels
Compatible with addressable zone interface I-9319
Compatible with C-9101/2/3/4
Dimension: Diameter 103mm, Height 37.4mm
16 Zone Conventional Repeater Panel
Revised Conventional Fire Panel
Compatible with GST102/4/8/16
Powered from FACP directly
Zonal Fire and general Fault indication
Dimension: 280mm x 110mm x 46mm
Pleasing colour and facia design
Re-arranged indication and operation panel
Simplifed user operation
Comply to latest EN54 standard
Pending panel under development
P-9907
GST-RP16
GST-101
GST-102
GST-104
GST-108
GST-116
Gas Extinguishing
System
52
Conventional Fire Alarm Panels
Conventional Gas Extinguishing Control Panel
Two plus one control panel
Standalone gas extinguishing control panel
2 conventional detection zones achieve double knock control
Additional standard fre detection zone for other areas (no effect on gas release)
Automatic and Manual extinguishing control
Numerical onboard timer control
Adjustable gas release delay timer
Duty and Standby Cylinder control
Two phase evacuation sounders
Adjustable Solenoid Pulsed output
Compatible with all GST conventional detectors
Fully compliant to BS/EN/CE standards
Built-in PSU and Charger
Addressable Gas Extinguishing Control Panel
Compatible with all GST Intelligent Fire Alarm Control Panels
Sits directly on addressable loop
Direct intelligent control via addressable Loop
Capable of controlling up to 6 zones of extinguishing
Auto and manual control facilities
Utilises GST intelligent detectors and programming (inc Fuzzy Logic) for control
Fully monitored status control
Requires 24VDC Power supply
GST-301
GST-303/306
53
The Intelligent Solution www.gst.com.cn
Emergency Start/Abort Switch
Emergency Start/Abort switch for gas extinguishing control
Compatible with GST301/303/306 gas extinguishing control panels
Gas Extinguishing Warning Indicator
Interposing Relay Module
Normally installed above the entrance to a gas extinguishing control area
Will eliminate and activate sounder prior to gas release
Compatible with GST303/306
Monitoring cable from gas panel to module
Apply power to solenoid valve for gas release initiation
Confrmation signal of pressure switch when activated
C-9317
C-9318
C-9329
Fire Telephone
System
55
The Intelligent Solution www.gst.com.cn
Fire Telephone Panel
Fire Telephone Panel
Technical Specifcations
Technical Specifcations
8 Zone conventional fre telephone center
2-way voice communication
Networkable up to 8 Fire Telephone panels
Call divert to the main panel
Operator can select single or group call
Operator can ring outstations and fxed handsets
Call panel to panel
Up to 10 communication points can be connected to each zone using socket jack
Network cable monitored
Communication line monitored
Wall mounted
24 Zone addressable fre telephone center
2-way voice communication
Networkable up to 8 Fire Telephone panels
Call divert to the main panel
Automatic record of conversation
Operator can select single or group call
Operator can ring outstations and fxed handsets
Call panel to panel
Up to 10 communication points can be connected to each zone using socket jack
Network cable monitored
Communication line monitored
19/3U standard rack mount
Operating Voltage: 24VDC
Standby Current: 150mA
Maximum Alarm Current: 750mA
Operating Environment:
Temperature 0~+ 40C
Relative Humidity 95%
Dimension: 400mm x 280mm x 100mm
Operating Voltage: 24VDC
Standby Current: 200mA
Maximum Alarm Current: 1 Amphere
Operating Environment:
Temperature 0~+ 40C
Relative Humidity 95%
Dimension: 482.5mm x 132.5mm x 225mm
GST-FT8WN
GST-FT24N
56
Fire Telephone System
Speaker Fire Telephone Outstation
Fixed Fire Telephone Handset
Fire Telephone Jack Socket
Fire Telephone Mobile Handset
Hand-free extension of Fire Telephone System
Compatible with all GST conventional fre telephone handsets in same zone
Dimension: 172mm x 106mm x 70mm
Fixed extension of Fire Telephone System
Open box and lift receiver to communicate with central control
Compatible with all GST conventional fre telephone handsets in same zone
Dimension: 234mm x 146mm x 60mm
Simply insert mobile handset into jack to establish communications with the
control centre
Compatible with all GST conventional fre telephone handsets in same zone
Dimension: 85mm x 85mm x 12mm
Mobile handset compatible with GST fre telephone jacks
Dimension: 210mm x 50mm x 50mm
P-9911(S)
P-9911(F)
P-9911(J)
P-9911(M)
Explosion Proof
Products
58
Explosion Proof Products
Intrinsically Safe Combination Heat/Photoelectric
Smoke Detector
Intrinsically Safe Conventional Rate of Rise and Fixed
Temperature Heat Detector
Technical Specifcations
Technical Specifcations
Drift compensation suits environment changing extensively
Integrated algorithm for analyzing fre, improving the sensitivity highly
Self-diagnostic
Removable innovative sensing chamber, easy for maintenance
Rate of rise and fxed temperature alarm modes
Twin LED for 360 view
Built-in microprocessor selects and processes data in real time
Designed to comply with EN 54-5 standard
Operating Voltage: 24VDC (16VDC~28VDC)
Standby Current: 60 A
Alarm Current: 10mA~30mA
Action Temperature: 58C
Wiring: Polarized two-wire for power
Ingress Protection Rating: IP22
Environment Temperature: -10~+50C
Relative Humidity: 95%, non condensing
Dimensions: Diameter 100mm; Height 56mm (with base)
Explosion-proof Mark: ExibIICT6
Operating Voltage: 24VDC (16VDC~28VDC)
Standby Current: 60 A
Alarm Current: 10mA~30mA
Action Temperature: 58C
Wiring: Polarized 2-core for detection zone cable
Ingress Protection Rating: IP33
Environment Temperature: -10~+50C
Relative Humidity: 95%, non condensing
Dimensions: Diameter 100mm; Height 58mm (with base)
Explosion-proof Mark: ExibIICT6
C-9101(EX)
C-9103(EX)
59
The Intelligent Solution www.gst.com.cn
Intrinsically Safe Conventional Sounder Beacon
Intrinsically Safe Conventional Sounder
Technical Specifcations
Technical Specifcations
High intensity red LED fashing beacon
Sound output 92dB at 1 meter
2 part construction for easy installation
Sound output 92dB at 1 meter
2 part construction for easy installation
Operating Voltage: Power Action: 24VDC (16V~28V)
Power Action Current: 50mA
Ingress Protection Rating: IP33
Environment Temperature: -10~+50C
Relative Humidity: 95%, non condensing
Explosion-proof Mark: ExibIICT6
Operating Voltage: Power Action: 24VDC (16V~28V)
Power Action Current: 35mA
Ingress Protection Rating: IP33
Environment Temperature: -10~+50C
Relative Humidity: 95%, non condensing
Explosion-proof Mark: ExibIICT6
C-9403(EX)
C-9404(EX)
60
Explosion Proof Products
Intrinsically Safe Manual Call Point
Explosion Proof MCP
Technical Specifcations
Technical Specifcations
Re settable non-breaking glass
Built-in 8-bit microprocessor control
Electronically addressed by handheld programmer
Non break-glass type, resetable by special key
With wide temperature range, high ingress protection rating, the MCP can
apply to vessels, outdoors and explosive hazardous environment
Operating Voltage: 24VDC (16VDC~28VDC)
Standby Current: 0mA
Alarm Current: 10-30mA
Wiring: Two wire
Ingress Protection Rating: IP40
Environment Temperature: -20~+40C
Relative Humidity: 95%, non condensing
Dimensions: 90mm x 122mm x 48.5mm
Explosion-proof Mark: ExibIICT6
Operating Voltage: Loop 24V
Operating Current:
Standby Current: 0.8mA
Alarm Current: 2mA
Operating Environment:
Temperature: -40~+70C
Relative Humidity: 95%
Dimension: 196mm x 129mm x 95mm
Ex Mark: ExibIIBT6/DIP A20 TA,T6
Ex Certifcate No.: CE061028
C-9201(EX)
DI-9204Exd
61
The Intelligent Solution www.gst.com.cn
Digital Flame Proof UV Flame Detector
Innovation Flame Proof UV Flame Detector
Technical Specifcations
Technical Specifcations
Built-in single chip microcomputer for signal processing and intelligent
communication control
Intelligent algorithm for fast alarm, response and superior false alarm rejection
Connect directly to GST addressable loop, compatible with all GST intelligent panels
Three (3) sensitivity levels
High sensitivity and reliable performance, dust/corrosion/humidity resistant
Adapted to explosive area 1 & 2
Built-in single chip microcomputer, intelligent algorithm for fast alarm response
(up to 100ms) high level of false alarm rejection
Normally open output for easy interfacing
Advanced ultraviolet photodiode for superior sensitity, reliable performance,
dust / humidity / corrosion resistant
Stylish pleasing design with aluminum alloy shell, small volume and light
weight for better mechanical strength
Operating Voltage: 24V
Operating Current:
Standby Current: 2mA
Alarm Current: 2.5mA
Operating Environment:
Temperature: -20~+40C
Relative Humidity: 95%
Dimension: 147mm x 103mm x 92mm
Ex Mark: ExibIICT6
Ex Certifcate No.: CE061027
Operating Voltage: 24V
Operating Current:
Standby Current: 2.5mA
Alarm Current: 15mA
Operating Environment:
Temperature: -20~+40C
Relative Humidity: 95%
Dimension: 147mm x 103mm x 92mm
Ex Mark: ExibIICT6
Ex Certifcate No.: CE061028
DC-9104Exd
DI-9104Exd
62
Explosion Proof Products
Digital Flame Proof Refective Beam Detector
Digital Flame Proof Dual IR Flame Detector
Technical Specifcations
Technical Specifcations
Integration of the emitting and receiving part makes for easy installation and
accurate optical pathway
Built-in microprocessor enables intelligent judgement of fre alarm and fault
Easy alignment ensures a single person installation
Self-diagnostic
Drift-compensation for factors weakness, such as dust contamination, positional
excursion and component ageing
Integrated functions for both addressable and conventional use
Electrically address by handheld programmer
Fire and fault volt-free contact output for Integration of the system
3 sensitivity levels can be set by programmer
SMT processing technology
Dual band Infrared fame detection
Immune to sunlight, artifcial light, heat radiation, providing a means of reliable operation
Integrated functions of both addressable and conventional
Electronically address by handheld programmer
Suitable for civil applications & hazardous industrial locations such as Zone 1,
Zone 2 in explosive environment and Zone 21 and Zone 22 in fammable dust atmosphere
Operating Voltage: 24V
Operating Current:
Power: Commission Current 20mA
Standby Current 12mA
Alarm Current 22mA
Loop: 2mA
Operating Environment:
Temperature: -20~+40C
Relative Humidity: 95%
Dimension: 344mm x 240mm x 212mm
Ex Mark: ExibIICT6/ DIP A21 TA, T6
Ex Certifcate No.: CNEx 06.0273
Operating Voltage: 24V
Operating Current:
Standby Current: 2mA
Alarm Current: 4mA
Operating Environment:
Temperature: -20~+55C
Relative Humidity: 95%
Dimension: 166mm x 235mm x 199mm (with frame)
Ex Mark: ExibIICT6/DIP A21 TA, T6
Ex Certifcate No.: CNEx 06.0273
D-9105(EX)
D-9107RExd
63
The Intelligent Solution www.gst.com.cn
Dual band Infrared fame detection
Immune to sunlight, artifcial light, heat radiation, providing a means of reliable operation
Integrated functions of both addressable and conventional
Electronically address by handheld programmer
Suitable for civil applications & hazardous industrial locations such as Zone 1,
Zone 2 in explosive environment and Zone 21 and Zone 22 in fammable dust atmosphere
Flame Proof Zone Monitor Interface
Flame Proof Sounder Control Interface
Technical Specifcations
Technical Specifcations
Connecting Intrinsically Safe Detectors and MCP into GST intelligent system
Electronically addressed
Energy limited to ensure the safety system operation
Zener Barrier inside
Connecting Intrinsically Safe Sounder into GST intelligent system
Activating notifcation in hazardous area in case of fre condition
Electronically addressed
Energy limited to ensure the safety system operation
Zener Barrier inside
Loop Voltage: 24V
Power Supply Voltage: 24VDC
Operating Current:
Standby Current: 0.5mA
Alarm Current: 5mA
Operating Environment:
Temperature: -10~+50C
Relative Humidity: 95%
Dimensions: 201mm x 172mm x 79mm
Loop Voltage: 24V
Power Supply Voltage: 24VDC
Operating Current:
Standby Current: 0.5mA
Alarm Current: 50mA
Operating Environment:
Temperature: -10~+50C
Relative Humidity: 95%
Dimensions: 201mm x 172mm x 79mm
I-9332
I-9333
64
Intelligent Fire Alarm System
I-9101 Intelligent
Combined Optical/Heat Detector
C-9503 Short
Circuit Isolator
I-9102 Intelligent
Optical Detector
I-9103 Intelligent
Dual Heat Detector
DI-9204
Manual Call Point
I-9300 Addressable
Input Module
I-9401 Addressable
Sounder Beacon
I-9301 Addressable
Single lnput/output Module
GST-IFP8 Eight Loops
Intelligent Fire Alarm Control Panel
PSU24-5
Power Supply
65
The Intelligent Solution www.gst.com.cn
Conventional Fire Alarm System
C-9403 Conventional
Sounder & Strobe
C-9403 Conventional
Sounder & Strobe
C-9101
Conventional
Optical/Heat Detector
C-9101
Conventional
Optical/Heat Detector
C-9103
Conventional Dual
Heat Detector
C-9102
Conventional
Optical Detector
GST108
8 Zone Conventional Fire Panel
C-9202
Conventional
Manual Call Point
C-9202
Conventional
Manual Call Point
Active End of Line
Active End of Line
66
Fire Telephone System
Speaker Handset
Speaker Handset
Fixed Handset
Fixed Handset
8 Zone Conventional Fire Telephone Panel
Mobile Handset
FT Socket FT Socket
FT Socket
67
The Intelligent Solution www.gst.com.cn
UL Listed Fire Alarm Diagram
I-9102(UL)Intelligent
Optical Detector
C-9503 Short
Circuit Isolator
DI-M9204
Manual Call Point
I-9103(UL)Intelligent
Dual Heat Detector
I-M9301 Addressable
Single Inputoutput Module
I-M9300 Addressable
Input Module
DC-M9204
Manual Call Point
C-9102(UL)
Conventional Optical Detector
C-9103(UL)
Conventional Dual
Heat Detector
Note: Pull Station, Flasher and other accessories are also available for a complete UL listed System.
GST-M200
Intelligent Fire Alarm Control Panel
GST China
17F, 2# Building, BOYA International Centre,
No.1 Lizezhongyi Road, Chaoyang District
Beijing 100102, P.R. China
Tel:+86 (0)10 8417 9816
Fax: +86 (0)10 8417 9816
www.gst.com.cn
sales@gst.com.cn
GST Dubai
ZA04, Jebel Ali Free Zone
P.O. Box 17998, Dubai
United Arab Emirates
Tel.: +971 (0)4 8833 050
Fax: +971 (0)4 8833 053
info@gst.uk.com
www.gst.uk.com
GST Vietnam
37/45 C1, Duong Cong Hoa P13,
Tan Binh District, HCM City, Vietnam
Tel: +84 8 2937 260
Fax: +84 8 2937 260

You might also like