Accessories Andrew PDF
Accessories Andrew PDF
Accessories Andrew PDF
PRODUCTS
PRODUCT SEL ECT I ON GUI DE 2007
Table of Contents
1 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com
A
B
D
A
D
E
F
C
A Cable Hoisting and Attachment
B Weatherproofing
C Cable Entry
D Grounding Kits
E Grounding Bars
F Arrestor Plus
Surge Arrestors
Introduction
Cable Installation Accessories
Cable Hoisting and Attachments ................................................. 8
Weatherproofing ....................................................................... 19
Cable Entry ............................................................................... 22
Installation Aids......................................................................... 24
Lightning Protection
Grounding Kits .......................................................................... 30
Grounding Bars ......................................................................... 34
Surge Arrestors ........................................................................ 37
Appendixes
Appendix 1: Quarterwave Stub Surge Arrestors ....................... 40
Appendix 2: Gas Tube Surge Arrestors .................................... 43
Appendix 3: dc Passing T-Series Surge Arrestors .................... 46
Appendix 4: Lightning Strike Probability .................................. 47
Appendix 5: Additional Documents .......................................... 48
Appendix 6: Hanger Spacing Guidelines .................................. 49
Index ............................................................................................... 58
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 2
Andrews Clear Advantage
Around the globe, in a world being transformed by communications, people anticipate more
than ever that wireless services will enhance their lives, workplaces, and communities.
With the convergence of voice, data, and video, we experience the promise of mobilityand we experience
Andrew. Andrew supports the emerging mobile society, and the companies that make this todays reality, with
complete wireless solutions. Our customers represent the leading wireless, broadband, and satellite communication
providers of the world. We support all major operators and OEMs in every region and are extremely proud of these
relationships, many of which we have served for decades.
Andrew solutions are technology agnostic and unbiased regarding platform, frequency and technology evolution,
even within our own product portfolio.
With our broad base of products, we support more global markets and offer more knowledge and experience in
licensing, spectrum analysis and utilization, asset optimization, and customized, multi-prong problem-solving for
building, optimizing, and enhancing networks for growth and success.
Simply, we understand your challenges and are uniquely prepared to help as an unmatched one-stop resource for
managing the entire life cycle of wireless networks.
Andrew provides products and solutions for the entire RF footprint with our Antenna and Cable passive products
and our Wireless Network Solutions active products. Our substantial investment in global research and development
ensures a pipeline of new products and solutions that address our customers evolving network requirements.
The Andrew flash represents an enviable 70-year legacy of customer service that brings us to today, with over
11,000 employees in 35 countries, and an unmatched global distribution network that ensures that our customers
receive essential support wherever and whenever they need it. Our talents, expertise, and commitment are always
nearby, and our local presence in every region of the world ensures cost-effective products and on-time delivery
and services.
Everywhere you look, the promise of mobility is hereand we at Andrew promise to listen, anticipate, and innovate,
and to continue to earn the trust and respect of our customers.
3 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com
n
Base Station Antenna and
Remote Electrical Downtilt
Systems
n
Microwave Antennas
n
Coaxial Foam, Air, and
Specialty Cable
n
Connectors, Surge
Arrestors, and Assemblies
n
Broadband Cables
n
Site Installation Products
and Services
n
Bias Tees
ANTENNA AND
CABLE PRODUCTS
n
Single-Carrier Power
Amplifiers
n
Multicarrier Power
Amplifiers
n
Custom In-Cabinet
Amplifiers
n
Custom In-Cabinet Filters
n
Tower Mounted Amplifiers
n
Filters/Combiners
n
Integrated Products
n
Micro/Pico Cells
n
Remote Radio Heads
n
After Market Services
BASE STATION
SUBSYSTEMS
n
Geolocation and
Location Based Services/
Geolocation Mobile
Location Solutions
n
Spectrum Management
n
Network Optimization
n
Network Infrastructure and
Program Management
n
Advanced Data Collection
NETWORK
SOLUTIONS
n
RF Repeaters
n
RF Boosters
n
Optical Distribution
Networks
n
Radiating Cable
n
Passive Splitters,
Combiners, Duplexers,
Terminators, and Indoor
Antennas
n
Operations and
Maintenance Center
n
Turnkey System
Design and Project
Management
WIRELESS
INNOVATIONS
n
Direct-to-Home Outdoor Units
n
Very Small Aperture Terminal
Outdoor Units
n
Earth Station Antennas
n
Gateway Systems
n
MilSatCom Antenna Systems
n
Government/Radar Antennas
n
RF Electronics
n
Site Installation and Services
SATELLITE
COMMUNICATIONS
Antenna and Cable Products Segment
Wireless Network Solutions Segment
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 4
Planning Software
AASPthe first and only PCS/Cellular Systems Design Software
Design your PCS or cellular system in
less time, with greater accuracy and
lower costs with advanced Andrew
Antenna Systems Planner software
(AASP). Powerful AASP software
graphically guides you through the
entire design process, from the
choice of frequency to the avail-
able shipping options. The programs
dynamic, rule-based logic generates
custom solutions by using standard Andrew
products while automatically checking component compatibility.
Upon completion, AASP provides you with a customized bill of
materials of the Andrew parts necessary for the system. AASP is
available on the Andrew Powertools CD or as a download from
www.andrew.com.
OnePack
SM
Site Kits
The Answer for More Efficient System Build-outs
Todays global build-out demands new solutions that speed system
deployment and simplify supply chain management. To help system
managers better achieve these goals, Andrew offers kits for wire-
less RF communications systems sites. OnePack Site Kits provide
the critical components in easy to order, easy to manage packages.
System designers and managers can be confident of shortened
project planning and execution cycles, improved efficiency, and
dependable system performance.
Customer Support Center (CSC)
Service Around the Clock, Around the World
Contact the Andrew Customer Support Center for:
d
Technical support
d
Order status
d
Coordinating product service, repairs, or replacement
d
Product information
d
Replacement materials
Call toll free from:
North America 1-800-255-1479
Fax 1-800-349-5444
International:
United Kingdom 0800-250055
Australia 1800-803 219
New Zealand 0800-441-747
Call from other areas: +1 708-873-2307
Services
Installation Techniques to Ensure Quality!
Andrew products and people are at the forefront of connecting
the wireless world. As the industry evolves, the Andrew Institute
is committed to providing you with quality, effective training.
Our trainers deliver knowledge that can develop your skills and
self-assurance, as well as benefit your system performance and
reliability. Dedicated Andrew Institute trainers will share their proven
installation techniques and expertise with you in one- or
two-day sessions.
Build an Agenda Customize Your Training:
Connector Attachment
(1 hour per connector)
d
Cable concepts
d
Connector attachment
d
Accessories
RET Antenna
(2 hours)
d
Antenna concepts
d
Mounting techniques
d
Weatherproofing
d
Inspection and maintenance
5 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 5
More customers are mandating that technicians installing their systems
are registered as having completed Andrew Institute training.
Orland Park, Illinois USA
Lochgelly, Scotland
Sorocaba, Brazil
Suzhou, China
Andrew Institute Technical Training
You will learn:
d
How to obtain the highest possible performance with every Andrew
product installed
d
System fundamentals and how components work together
d
Proper installation of cable, connectors, and accessories through
hands-on practice
d
TMW systems fundamentals and essential elements of path alignment
d
Pressurization systems theory of operation and installation techniques
d
Proper path alignment
d
Fundamentals of VSWR sweep testing, insertion loss, and TDR/FDR plots
The Andrew Institute welcomes the opportunity to serve the industry. We
can bring select courses to your facility, or you can come to any one of our
convenient training locations.
Terrestrial Microwave Systems
(2 days)
d
RF theory/TMW fundamentals
d
Antenna installation
d
Path alignment
d
Pressurization fundamentals
For more information visit our Web site at: www.andrew.com
Registration is available online or call: +1-779-435-6231
Fundamentals of VSWR
(4 hours)
d
Typical site configuration
d
Plot/sweep interpretation
d
Troubleshooting
Selection Guide
Elements of a Cable Mounting and Protection System
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 6
Once youve selected the cable and connectors for your system, the cable mounting and protection system must
be planned. Andrew offers a comprehensive line of installation accessories and lightning protection systems to
help you realize your communications systems full potential.
Hoisting Grips
Select a hoisting grip to safely raise the
cable and hold it during hanger attachment.
In some cases, a hoisting grip must also be
used with a calibrated clamp, available from
Andrew, to provide permanent support for
the cable.
Hangers
The type or shape of the structure, the space
available for cable attachment, the type of
environment the system will be exposed to,
and the ease of installation or maintenance
are key considerations. Many hanger options
are available, and many variables have
tradeoffs that affect total hanger system cost.
The table on page 18 will help you select the
best hangers for your system and budget.
Weatherproofing
Weatherproofing keeps connector interfaces
tight and adds an additional layer of protection
against the environment. Andrew offers three
types of weatherproofing. A standard weather-
proofing kit provides universal coverage
and uses butyl and vinyl tapes to wrap
connector surfaces. Our 3M Cold Shrink
weatherproofing kit uses a self-shrinking
technology to reduce installation time. New
WeatherShield enclosures seal and protect
connectors for the environment in seconds.
Cable Entry
The final step in a base station installation
is to bring the cable into the building or
radio cabinet. Two basic types of cable
entry systems are available: a standard
building entry, and an integrated system
that combines cable entry and lightning
surge suppression into one efficient system.
Grounding Kits
A grounding kit diverts transient currents
from lightning off the transmission line
to an earth grounding system to prevent
damage to cable and radio equipment. A
typical installation uses three grounding
kits: near the top of the main feeder cable,
at the bottom of the main feeder prior to the
horizontal run, and just prior to the cable
entering the building. Andrew offers three
kit types to meet the requirements of your
system and budget.
Surge Arrestors
Andrew Arrestor Plus
surge arrestors
provide the last stage of an effective
lightning protection system. Install them
to divert lightning transients off the inner
conductor of your coaxial cable before they
reach your radio equipment. Select from a
variety of surge arrestors to meet your
exact requirements.
( Cable Hoisting and Attachment
( Weatherproofing
( Cable Entry
( Installation Aids
C
A
B
L
E
I
N
S
T
A
L
L
A
T
I
O
N
A
C
C
E
S
S
O
R
I
E
S
Cable Installation Accessories
Cable Hoisting and Attachment
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 8
Support/Hoisting Grip
Safer, Faster Cable Hoisting
Lift and support cable in your monopole or on your tower faster and
more safely and without the threat of slippage. Our one-piece grip
and locking clamp speed and simplify installation by eliminating time
consuming lacing.
Use at 200 ft (60 m) intervals to raise cable and provide permanent
cable support. Basic kit includes one grip and one support clamp.
Support clamps are also available in kits of 10. Installation tool is
required.
Part Number Part Number
Support Grip Support Clamp Cable Size Cable Type
F1SGRIP F1SGRIP-1IK 1/4" FSJ1
L1SGRIP L1SGRIP-1IK 1/4" LDF1
E2SGRIP E2SGRIP-2IK 3/8" EFX2
L2SGRIP L2SGRIP-2IK 3/8" LDF2
F2SGRIP F2SGRIP-2IK 3/8" FSJ2
C2SGRIP C2SGRIP-2IK 3/8" CNT-400
L4SGRIP L4SGRIP-4IK 1/2" LDF4
F4SGRIP F4SGRIP-4IK 1/2" FSJ4
L45SGRIP L45SGRIP-45IK 5/8" LDF4.5
L5SGRIP L5SGRIP-5IK 7/8" LDF5, VXL5
L6SGRIP L6SGRIP-6IK 1-1/4" LDF6, VXL6
L7SGRIP L7SGRIP-7IK 1-5/8" LDF7, VXL7
L12SGRIP L12SGRIP-12IK 2-1/4" LDF12
3CCGRIP RET cable
Part Number Description
SG-IT Support Clamp Installation Tool
Standard Hoisting Grip
For Transmission Line Installation
Use at 200 ft (60 m) intervals to raise cable on tower. Use with addi-
tional support clamp to achieve optimum cable grip.
Part Number Part Number
Hoisting Grip Support Clamp Cable Size
43094 L4SGRIP-4IK 1/2"
29958 L45SGRIP-45IK 5/8"
19256B L5SGRIP-5IK 7/8"
29961 L6SGRIP-6IK 1-1/4"
24312A L7SGRIP-7IK 1-5/8"
31535 L12SGRIP-12IK 2-1/4"
26985A 3"
34759 4"
31031-1 5"
Use the support/hoisting grip whenever possible. Rely on the standard,
lace up hoisting grip only when connectors are pre-attached or you have
to place a grip in the middle of a cable run over 200 ft.
TIP!
TIP!
Cable Installation Accessories
Cable Hoisting and Attachment
9 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com
Snap-In Hangers
Attachment with No Hardware!
Andrew Snap-In hangers provide quick and easy attachment in all types
of weather. The hangers snap directly into holes in the tower support
members. Installation time and costs are substantially reduced. These
hangers feature cable gripping tabs to prevent cable slippage, and are
constructed of heavy gauge stainless steel for high strength and excel-
lent corrosion resistance. Waveguide versions include a heavy UV resis-
tant rubber insert to secure the elliptical waveguide.
Part Number Description
206706A-6 For 5/8" cable
206706A-5 For 2-1/4" cable
EWSH-52 For EW52 waveguide
EWSH-63 For EW63 waveguide
EWSH-64 For EW64 waveguide
EWSH-77 For EW77 waveguide
EWSH-90 For EW90 waveguide
EWSH-127A For EW127A waveguide
EWSH-132 For EW132 waveguide
EWSH-180 For EW180 waveguide
EWSH-220 For EW220 waveguide
EWSH-240 For EW249 waveguide
SnapStak
Hangers
No more worries about fumbling with hardware or losing small
partsbecause there arent any!
New antenna systems can now be added to crowded multiple-tenant
towerswith minimal space! SnapStak snap-in hangers can be
stacked up to three deep when using 1/2 in and 7/8 in coaxial cable, or
two deep when using 1-1/4 in and 1-5/8 in coaxial cable. Each hanger
accommodates one run of HELIAX
cable.
The distinctive, self-contained design of the SnapStak stackable snap-
in hanger eliminates the need for mounting hardware and installation
tools. This simplifies coaxial cable installations, lowering both time and
cost.
Retention tabs on the spring fork make SnapStak hangers highly resis-
tant to pop-out, so installations are robust and secure. Yet, specially
designed to dampen vibrations, SnapStak hangers do not have a rigid
hold on the tower, so motion caused by wind is simply absorbed. This
reduces movement down the coaxial cable, greatly reducing stress on
the connections at the jumper cable, antenna, or device.
SnapStak hangers can be mounted directly to the tower support
system, or used in conjunction with a variety of mounting accessories
for rooftops, buildings, and water towers. The SnapStak hanger installs
in 3/4 in holes in support structures 1/8 in (0.120 in to 0.150 in)
thick. The stainless steel construction of the SnapStak snap-in hanger
provides exceptional integrity, even in highly corrosive environments and
extreme weather conditions. Compact installations save tower space.
And maintenance is easy, since SnapStak stackable snap-in hangers
are self sufficientno hardware required for installation! Mounts to
pre-punched 3/4 in (19 mm) holes, kit of 10.
Part Number Description
SSH-12 SnapStak hanger kit for 1/2" corrugated cable
SSH-78 SnapStak hanger kit for 7/8" corrugated cable
SSH-114 SnapStak hanger kit for 1-1/4" corrugated cable
SSH-158 SnapStak hanger kit for 1-5/8" corrugated cable
SSHAK-3812 SnapStak hanger kit for RET cable
SSHA-38 Insert, adapts 1/2" snap in hanger to RET cable
United States Patents: 6,345,543, 6,899,305, and 6,161,804.
Other patents pending.
Cable Installation Accessories
Cable Hoisting and Attachment
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 10
Snap-In Tower Standoffs
For mounting snap-in hangers to round support members. Adapter is
designed with 3/4 in pre-punched hole. Adapter provides 2-1/2 in (60
mm) standoff. All parts are stainless steel or galvanized, kit of 10.
Part Number Member Diameter, in (mm)
STS3-12 12 (2550)
STS3-23 23 (5075)
STS3-34 34 (75100)
STS3-45 45 (100125)
SnapStak
Hanger Tool
Specially designed pliers make installation and removal of SnapStak
snap-in hangers extremely easy. The spring loaded pliers are designed
with a hook that holds and spreads the hanger open to slip easily over
the cable. Serrated pads then squeeze the hanger together for effortless
insertion into the mounting structure. Insulated handle and a lanyard
hole make it easy to hang on to.
Part Number Description
SHT-4 SnapStak hanger tool, quantity 1
Part Number Description
UA-3 Universal snap-in adapter, kit of 10
Universal Angle Adapter Insert
Insert transitions the universal adapters 3/4 in to a 3/8 in hole diameter,
which allows the use of standard hangers.
Part Number Description
UAAI Universal angle adapter Insert, kit of 10
Each part sold separately
( UA-3
( UAAI
Universal Snap-In Adapter
The universal snap-in adapter is a versatile device for securing coaxial
cable hangers to structures such as communications towers, rooftops,
buildings and water towers.
The universal snap-in adapter secures coaxial cable to any round or
angle tower members where pre-punched holes are not easily acces-
sible. The adapter has a pre-punched 3/4 in hole that allows the installer
to mount cable hangers such as Andrew SnapStak snap-in hangers
to wireless communications towers or other structures. Stainless steel
construction for long life.
Universal Adapter Applications
Cable Installation Accessories
Cable Hoisting and Attachment
11 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com
Cluster Support Bracket
The cluster support bracket is a versatile means to support multiple
runs of coaxial cable in virtually any application. The oval design allows
coaxial cable to be run inside and outside of the bracket, which maxi-
mizes its capacity. Each bracket features 3/4 in holes to accommodate
snap-in hangers and 3/8 in holes for butterfly hangers using standard
3/8 in hardware. The cluster support bracket supports seven runs of
coaxial cable. Sold in units of one, U-bolt hardware sold separately.
Part Number Description
CS-B Cluster support bracket with U-bolt
for 2-3/8" round member attachment
PVC Roof Sleeper
Support rooftop coaxial cable runs using the snap-in PVC roof sleepers.
PVC roof sleepers are pre-punched with 3/4 in holes to accommodate
snap-in hangers. Sleepers are made of a gray 4 in (102 mm) x 4 in (102
mm), UV-resistant PVC material.
Part Number Description
MT-F1598 4 run, 22" (559 mm) length
MT-F1599 8 run, 32" (810 mm) length
MT-F1600 12 run, 43" (1102 mm) length
Snap-In Adapter Bracket
This bracket is used in conjunction with WRAPLOCK
and is used on
large, round members, water towers, or outside of a monopole. The
brackets slide on the WRAPLOCK and hold up to six runs of coaxial
cable. You can use multiple brackets for the number of runs required
for your system. The galvanized steel bracket supports both standard
hangers and snap-in hangers. Accommodates six runs of snap-in
hangers and four runs of click-on hangers.
Part Number Description
RM-USBG Snap-in adapter bracket, kit of 10
12395-1 Stainless steel WRAPLOCK
Universal Snap-In Bracket
These galvanized steel brackets are designed to work on both angle
and round members. They are pre-punched with 3/4 in holes to hold
snap-in hangers or standard hangers.
Part Number Description
SS-TB2550 Universal snap-in bracket, for 1-1/2" to 5-9/16"
round member 2-1/2" to 5" angle member.
Accommodates six snap-in or standard hangers.
SS-TB6080 Universal snap-in bracket, for 6" to 10-3/4"
round member 6" to 8" angle member
accommodates six snap-in or standard hangers.
Anchor Rail Adapter
Anchor rail adapters make cable installation fast, secure,
and neat.
These one-piece, one-size, self-contained anchor rail adapters require
no tools and snap into common strut or anchor rail systems, such as
UniStrut
Hangers
Multiple Run Cable Hangers for European Norms
Ideal for multiple run cable hangers designed exclusively for European-
style towers, cost effective KwikClamp cable hangers eliminate the need
for drilling and adapters. These self-clamping cable hangers attach
directly to round or flat tower members, providing sturdy, reliable,
long-term support to systems. Hangers are sold in kits of 10.
KwikClamp Ordering Information
See the table below to build a KwikClamp part number for your application.
1 Select your cable size and note the base part number shown
below that cable size.
2 Select the tower member type and the number of cable runs
for your application.
3 Locate the part number detail at the junction of the cable size
column and the tower member type row. The base part number
plus the part number detail indicates the full part number.
For example, the KwikClamp hanger part number for three runs of
7/8 inch cable on an 825 mm round tower member is L5CLAMP-RDN-3.
Cable and Hanger Type
Cable Size RG8 1/2" 5/8" 7/8" 1-1/4" 1-5/8"
Base Part Number R8CLAMP-( ) L4CLAMP-( ) L45CLAMP-( ) L5CLAMP-( ) L6CLAMP-( ) L7CLAMP-(
Tower Member Type # of
Runs Part Number Detail
3-11 mm 2 UNV-2
8-25 mm round or
3-25 mm at plate 1 RDN-1 RDN-1 RDN-1 RDN-1 RDN-1
2 RDN-2 RDN-2 RDN-2 RDN-2 RDN-2
3 RDN-3 RDN-3 RDN-3 RDN-3 RDN-3
Cable Installation Accessories
Cable Hoisting and Attachment
15 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com
Standard Hangers
Standard Hangers and HardwareFor Security and Flexibility
Standard hangers are designed for easy installation. The clamp locking
bolt and nut are pre-assembled and captivated to minimize installa-
tion labor. Proper tension is easy to determine. The hanger is simply
tightened until there is a 5/16 in gap between the clamp legs. The pre-
drilled hole for 3/8 in or 1/2 in mounting hardware and slots for round
member adapter clamps further simplify installation. See pages 1618
for accessories to adapt these hangers to most tower configurations.
Please refer to Appendix 6 for specific recommendations.
Hanger
Part Number Cable Size Photo Reference
43211A 3/8" A
43211A 1/2" A
42396A-9 5/8" B
42396A-5 7/8" B
42396A-1 1-1/4" B
42396A-2 1-5/8" B
42396A-4 2-1/4" B
31766A-11 3" C
31766A-10 4" C
Hanger Waveguide
Part Number Size Photo Reference
31766A-9 EW17 C
31766A-10 EW20 C
31766A-11 EW28 C
42396A-4 EW37 B
42396A-16 EW43 B
42396A-8 EW52 B
42396A-7 EW63 B
42396A-1 EW64 B
42396A-11 EW77 B
42396A-5 EW85 B
42396A-5 EW90 B
42396A-9 EW127A B
42396A-9 EW132 B
43211A EW180 B
43211A EW220 B
43211A EW240 B
Hardware Sets, Kit of 10
Imperial kits include 3/8 in fillister-head bolts, lock washers, and nuts
for attachment of standard hangers to drilled tower members. The
metric kit includes M10 bolts and lock washers for use with metric
angle adapters.
Part Number Length
31769-5 3/4" (19 mm)
31769-1 1" (25 mm)
243684-MH Metric M10 19 mm
Additional Mounting Hardware
Threaded Rod Support Kit for Standard Hangers.
Use to mount hangers away from supporting structure, under cable
bridge, and inside equipment room. Includes 3/8 in diameter threaded
rod, galvanized ceiling mounting plate, nuts, and washers. Attach to
angle tower members with 31768A angle adapters. Attach to round
tower members with 30848 series tower standoffs. All components are
stainless steel, except ceiling mounting plate.
Part Number Part Number Rod Length, in (mm)
Kit of 1 Kit of 5
31771 31771-4 12 (305)
31771-9 31771-6 24 (610)
31771-10 36 (915)
A B C
Cable Installation Accessories
Cable Hoisting and Attachment
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 16
Angle Adapter
Stainless steel, kit of 10. For mounting 1/2 in to 4 in cable hangers
to angle tower members up to 7/8 in (22 mm) thick. Includes hanger
attachment hardware.
Part Number Description
31768A 3/8" hardware
31768A-M Metric hardware
Round Member Adapter
Stainless steel clamps to mount 1/2 in to 4 in cable hangers to round
support members. Two each are needed for 3 in and 4 in cable
hangers, kit of 10.
Part Number Member Diameter, in (mm)
31670-1 12 (2550)
31670-2 23 (5075)
31670-3 34 (75100)
31670-4 45 (100125)
31670-5 56 (125150)
31670-6 68 (150200)
Angle Adapter
Galvanized and Non-marring
For mounting 1/2 in to 2-1/4 in cable hangers to angle tower members
up to 3/4 in (19 mm) thick. Hanger attachment hardware sold sepa-
rately, kit of 10.
Part Number Description
247763-I Tapped for 3/8" hardware
247763 Tapped for metric hardware
Compact Stainless Steel
Angle Adapters
These compact, lightweight, high quality stainless steel angle adapters
provide a cost saving option to standard adapters for many wireless
systems that use HELIAX
Fastest hanger
installation; No
additional hardware
needed
Attaches cables in
compact three run
bundles
Impervious to
environmental
extremes
Universal hanger
accommodates all
corrugated cables
3/4" drilled
cable ladder
Various adapters
(see pages 1011)
None
Cluster mount
Universal tower
adapter
Impervious to
environmental
extremes
Adaptable to various
tower congurations
Various adapters
(see pages 16-17)
Tower attachment
hardware kit
Round member
adapter
Angle adapter
Support/
Hoisting Grips*
Tin coated bronze
1
Monopole towers
2
Calibrated clamp
provides permanent
cable support
Quick installation
Monopole
application
Accommodates
single run of cable
All towers and
monopoles
None
None required
Cable Ties**
Nylon
1
Jumper cables and
inter-rack cabling
Universal fastening
Quick installation
Inexpensive
Accommodates
single run of light-
weight cable
Round member,
angle member,
cable ladders
None
None required
Conditions
* Support grip or hoisting/support grip required with all cable installations
** Should only be used with 1/2 in cable and smaller
*** Installation time based on a 100 ft (30 m) run of 7/8 in cable with 3 ft (1 m) hanger spacing. Monopole application applied 200 ft intervals, 2 minutes.
Click-On Single,
Double, or
Miniature Hangers
Engineered plastic
single or double
2 to 6
Rooftops, water
towers, and towers
with limited space
20
Stackable up to
three high
Attaches cables in
compact six run
bundles
Versatile and
adaptable to almost
any application
Easy to install
click-on design
UV stable
Various adapters
(see pages 1213)
Threaded rod and
hardware
Round member
adapter
Angle adapter
KwikClamp
Hangers
Stainless steel
and plastic
1 to 3
New or existing
towers
15
Built in tower
adapter
Requires no
additional
hardware for tower
attachments
Quick installation
UV stable
Round member
Angle member
channel section
Cable ladders
None
None required
Cable Installation Accessories
Hanger Selection Guide
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 18
NEW! WeatherShield Reusable Connection Protection
Enclosures
For In-Line Connectors, Antennas, and Tower Top Devices
Complete your transmission line installation with WeatherShield connec-
tion protection enclosures which seal and protect connectors from the
environment.
This robust, one-piece weatherproofing enclosure offers an additional
measure of system protection by providing a high temperature resistant,
watertight seal around the connectors while also helping to dampen
vibration that can loosen connector interfaces over time.
The reusable enclosure contains an innovative trifold seal that provides
complete moisture block for installed connectors. The ease of instal-
lation on hard-to-reach connections and the long-term protection
provided by this enclosure makes it the most cost-effective solution
available today. The WeatherShield connection protection enclosure
takes just seconds to install. Simply place the housing around the
connector and snap the tabs together.
No tapes, tools, or shrink tubes are required. The Andrew WeatherShield
connection protection enclosures will accommodate Type N and
7-16 DIN connections and are compatible with Andrew HELIAX
cable,
SureFlex cable assemblies, and most brands of standard jumpers.
Part Number Description
AWE-A12 Enclosure for 1/2" antenna connection/device
AWE-7812 Enclosure for 7/8" to 1/2" connections
AWE-11412 Enclosure for 1-1/4" to 1/2" connections
AWE-15812 Enclosure for 1-5/8" to 1/2" connections
Cable Installation Accessories
Weatherproong
19 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com
More Information: See the installation video at www.andrew.com/
products/trans_line/heliax/weathershield.aspx
Cable Installation Accessories
Weatherproong
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 20
Part Number Minimum Application Diameter, in (mm)* Kit Coverage, Cable Size to Cable Size
Connectors, 7-16 DIN or Type N
245173 0.630.41 (1610.0) 3/8" through 1/2" to 3/8" through 1/2"
241475-13 0.800.29 (207.4) 1/4" through 5/8" to 1/4" through 1/2"
245171 0.840.29 (27.4) 7/8" to 1/4" through 1/2"
245172 1.200.29 (307.4) 1-5/8" or 1 1/4" to 1/4" through 1/2"
245175 1.400.41 (3610.0) 2-1/4" to 1/4" through 1/2"
Antennas, lters, ampliers, 7-16 DIN or Type N**
245174 0.840.29 (217.4) 1/2"7/8" jumpers to antenna
* Minimum application diameter is the fully compressed diameter of each tube in the kit.
**Andrew 3M Cold Shrink Weatherproofing is completely compatible with Andrew base station antennas.
See special publication SP50030 for specific application information on the use of Cold Shrink for antenna interfaces.
Weathertight Seal
Quickly Installs in Three Minutes
Complete your transmission line installation with the premier
weatherproofing product to seal and protect connectors, splices, surge
protectors, and jumper-to-antenna interfaces from the environment.
Andrew 3M Cold Shrink weatherproofing protects your investment
and your systems performance.
No Tools Required
Cold Shrink weatherproofing simply slips over the connection and
compresses around the interface. No tapes or heat guns are required
for sealing or shrinking. Simply place the Cold Shrink kit over the cable
and connector, make the connection, and unwind the pull-tab applicator.
Once it is collapsed, its continuous compression design forms a
watertight seal around the cable. Developed jointly by Andrew and 3M
Corporation, Cold Shrink weatherproofing has proven itself in thousands
of high power cable installations for more than 15 years.
Fits up to 2-1/4 in HELIAX
Cable
Kits are available for transitions from larger to smaller diameter cable,
such as 1-5/8 in to 1/2 in, or for same diameter cable, such as 1/2 in
to 1/2 in. See the table for part numbers.
3M and Cold Shrink are trademarks of Minnesota Mining and Manufacturing Company
Self-fusing Tape
Self-fusing and marking tape is a time saving alternative to traditional
butyl rubber sealant tapes. The silicone tapes are produced from
specially formulated UV-resistant silicone rubber. When applied to
RF connectors, the tape wraps bond together giving the connection
an additional layer of protection against water, dirt, and vibration.
Compared to conventional tapes, self-fusing tape is both easy to
apply and remove from connections.
Available in three colors options, self-fusing tape can also be used to
color code tower top cable installations, making it easy to locate cables
for monitoring purposes.
Part Number Description Quantity
FT-TB Self-fusing tape, black .030" x 1.5" x 15' 2 rolls
FT-TR Self-fusing tape, red .030" x 1.5" x 15' 2 rolls
FT-TW Self-fusing tape, white .030" x 1.5" x 15' 2 rolls
Cable Installation Accessories
Weatherproong
21 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com
Standard Weatherproofing Kit for Connectors
and Antennas
The application of sealing materials to antenna cable connections
protects them from weather conditions. These include moisture penetra-
tion and loosening of connections from vibrations caused by strong
winds. Andrew Corporation recommends weatherproofing these connec-
tions with standard weatherproofing tapes such as butyl and plastic
electrical tapes.
d
Main feeder cable-to-jumper cable connection
d
Jumper cable-to-antenna connection
This kit provides an additional moisture seal for cable connections.
It also prevents loosening of connections from vibration or other external
stresses, which would eventually allow moisture penetration. The sealed
connection is suitable for typical exposed and buried cable applications.
Weatherproong Connections Per Kit
Applications
Connection Type Per Kit
2-1/4" to 1/2" (57 mm to 13 mm) 2
1-5/8" to 1/2" (41 mm to 13 mm) 2
1-1/4" to 1/2" (32 mm to 13 mm) 2
7/8" to 1/2" (22 mm to 13 mm) 4
1/2" to 1/2" (13 mm to 13 mm) 12
7/8" to antenna, amplier, device (22 mm to 13 mm) 12
1/2" to antenna, amplier, device (13 mm to 13 mm) 12
Installation Tips
d
When applied, the tape must be above 32F (0C) to ensure adhe-
sion. Keep tape warm by carrying in coat pockets.
d
Do not stretch the tape. Apply only enough tension to provide a
smooth wrap.
d
Smooth each wrapped layer with your hands to ensure
full adhesion.
d
Do not pull the tape to tear tapealways cut it. (Pulled tape eventu-
ally unravels, decreasing protection.)
d
Add extra final layers of tape in warmer climates where there will be
long exposure to damaging ultra violet (UV) rays. Two or three extra
layers of tape will provide additional UV protection.
d
When wrapping tape, overlap the tape to half-width.
d
Ensure vent or drain holes at the bottom of the antenna or device are
not covered with weatherproofing tape.
Andrew 221213 Weatherproofing Kit contains:
2 rolls of 3/4 in x 66 ft black plastic tape
1 roll of 2 in x 20 ft black plastic tape
6 rolls of 2-1/2 in x 24 in butyl rubber tape
Colored Electrical Marking Tape
Colored tape is a convenient way to mark and code cable runs.
Six different colors are available in 3/4 in x 66 in rolls. Sold in
individual rolls.
Part Number Description
CM-TB Blue, 3/4" x 66' (19.1 mm x 20.1 m)
CM-TBR Brown, 3/4" x 66' (19.1 mm x 20.1 m)
CM-TG Green, 3/4" x 66' (19.1 mm x 20.1 m)
CM-TR Red, 3/4" x 66' (19.1 mm x 20.1 m)
CM-TW White, 3/4" x 66' (19.1 mm x 20.1 m)
CM-TY Yellow, 3/4" x 66' (19.1 mm x 20.1 m)
Standard Weatherproofing Tape
Part Number Description
221213 Complete kit, black
221213-S Complete kit, slate gray
42615-10 2-1/2" x 24" butyl rubber roll
9905-41 3/4" x 66' black plastic tape roll
9905-71 2" x 20' black plastic tape roll
Cable Installation Accessories
Cable Entry
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 22
Multiple Entrance Wall/Roof Feed-Thru Plate
Plate with one or more 4 or 5-inch holes. Weatherproof sealing caps
included. Use with the corresponding size rubber cable boot (sold sepa-
rately).
Part Number Number Height, Width
of Openings in (mm) in (mm)
4 in (102 mm) Entry Opening, Multiple Entrance Plate
204673-1 1 7.0 (178.0) 7 (178)
204673-2 1 5.0 (127.0) 5(127)
204673-2A 3 9.5 (241.3) 20 (508)
204673-4 4 9.5 (241.3) 25.5 (648)
204673-6 6 17.5 (444.0) 23 (584)
204673-8 8 17.5 (444.0) 25.5 (648)
204673-9 9 23.0 (584.0) 23.0 (584)
204673-10 10 9.5 (241.3) 31.0 (787)
204673-12 12 25.5 (648.0) 25.5 (648)
204673-16 16 25.5 (648.0) 25.5 (648
204673-18 18 25.5 (648.0) 39.5 (1003)
204673-20 20 28.8 (731.0) 31.0 (787)
204673-24 24 31.0 (787.0) 39.5 (1003)
Hole Plugs
Part Number Description
PLUG-12 Plug, 1/2", for unused cable boot holes, kit of 5
PLUG-78 Plug, 7/8", for unused cable boot holes, kit of 5
PLUG-114 Plug, 1-1/4", for unused cable boot holes, kit of 5
PLUG-158 Plug, 1-5/8", for unused cable boot holes, kit of 5
Standard Cable Entry Boots
Use with feed-thru plate with the corresponding size entry hole.
Cable Boot Cable Number of
Part Number Size Holes in Boots
4 in (102 mm) Cable Boots
204679A-17 1/4" foam 3
204679A-19 3/8" foam 1
204679A-5 1/2" foam 1
204679A-7 1/2" foam 3
204679A-6 1/2" air 1
204679A-1 1/2" air 3
204679A-16 1/2" 4
204679A-13 5/8" 1
204679A-14 5/8" 3
204679A-2 7/8" 1
204679A-18 7/8" 2
204679A-15 7/8" 3
204679A-3 1-1/4" 1
204679A-4 1-5/8" 1
204679A-8 2-1/4" 1
204679A-9 3" 1
CAP-4 Blank cap 0
5 in (127 mm) Cable Boots
48939A-16 3/8" foam 3
48939A-6 1/2" foam 1
48939A-8 1/2" foam 3
48939A-7 1/2" air 1
48939A-5 1/2" air 3
48939A-17 1/2" 4
48939A-14 5/8" 1
48939A-15 5/8" 3
48939A-1 7/8" 1
48939A-2 7/8" 3
48939A-3 1-1/4" 1
48939A-4 1-5/8" 1
48939A-9 2-1/4" 1
48939A-10 3" 1
EP-CAP5 Blank cap 0
Single Entrance Wall/Roof Feed-Thru Assembly
Includes rubber boot, clamp, and aluminum plate.
Order from table.
Part Number Cable Size
SCE-12 1/2"
SCE-58 5/8"
SCE-78 7/8"
SCE-114 1-1/4"
SCE-158 1-5/8"
SCE-214 2-1/4"
ArrestorPort
II
Integrated Transmission Line Entry/Ground System
The ArrestorPort II integrated building entry/ground system
redefines the way you achieve cable shelter entry and grounding.
Traditional installations rely on a piecemeal approach that steals time
and increases costs. ArrestorPort II unifies the installation of entry ports,
Arrestor Plus
precision
cutting tool is the only cutting tool made exclusively for HELIAX
coaxial cable.
Remove 2
of jacketing
MCPT-78 Rotation
Cable Installation Accessories
Installation Aids
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 26
Connector Attachment Torque Wrenches
Preset to Andrew Specifications
Andrew torque wrenches attach any type of HELIAX
connectors to
HELIAX LDF4.5, LDF5, LDF6, LDF7, and LDF12 coaxial cables. All are
designed with a mechanism to audibly notify the installer that the proper
torque has been reached and release the pressure.
Part Number Cable Type Connector Type
247696 LDF4-50A OnePiece
245154 LDF4-50A RingFlare
244376 LDF4.5-50 RingFlare and Standard
244378 LDF5-50A, OnePiece, RingFlare,
AVA5-50 and Standard
and VXL5-50
244375 LDF6-50 RingFlare and Standard
247698 LDF6-50 LDF6 OnePiece only
244374 LDF7-50A OnePiece, RingFlare
and Standard
244374 VXL7-50 OnePiece, RingFlare
and Standard
244373 LDF12-50 Standard
244379 All Type N coupling nut
244377 All 7-16 DIN coupling nut
247696 LDF4-50 OnePiece
Crimping Tool
Used to attach crimp-on lugs for standard and SureGround series.
Not required for kits having factory-attached lugs.
Part Number
207270
Aluminum Grounding Kit Tool
Now installers can prepare transmission line cable for grounding
kit installation in one simple, precise stepand without using a
knife! The Andrew aluminum grounding kit preparation tool takes
just seconds to use: simply snap the tool in place around the
cable and rotate. In one step the tool removes the exact amount of
jacketing necessary to attach the grounding strap. The grounding
kit preparation tool is a manually operated cutting device that
quickly trims away a section of cable jacket for the purpose of
grounding strap installation. The tool is ideal for use on cables
mounted close to structures and other cable runs, and will not
scrape or damage the cables outer conductor.
Part Number Cable Type Grounding Kit Type
GKT-F4A FSJ4 Standard
GKT-L4A LDF4 Standard, CSGL, SGL,
and SGPL series
GKT-78A LDF5, VXL5, AVA5, AL5 Standard, CSGL, SGL,
and SGPL series
GKT-114A LDF6 Standard, CSGL, SGL,
and SGPL series
GKT-158A LDF7, VXL7, AVA5, AL7 Standard, CSGL, SGL,
and SGPL series
Part Number Replacement Blade Kit
GKT-F4A GKT-BKF4
GKT-L4A GKT-BK512
GKT-78A GKT-BK512
GKT-114A GKT-BK67
GKT-158A GKT-BK67
Cable Installation Accessories
Installation Aids
27 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com
Description
Complete tool box kit includes all individual tools marked
with an asterisk in the list below.
Manual cable preparation tool for 1/4" FSJ1-50 cable
Cut-off tool 7/32"
Cut-off tool 8/32"
Cut-off tool 9/32"
Manual cable preparation tool for 3/8" FSJ2-50 cable
Cut-off tool 7/32"
Cut-off tool 8/32"
Cut-off tool 9/32"
Automated/manual cable preparation tool for 1/2" coaxial
superexible cable
Manual cable preparation tool for 1/2" superexible
FSJ4-50B cable
Chamfer tool
Cut-off tool 7/32"
Cut-off tool 8/32"
Cut-off tool 9/32"
Automated/manual cable preparation tool for
1/2" coaxial cable
21 mm torque wrench for L4 OnePiece connectors
3/4" torque wrench for L4 RingFlare connectors
Manual cable preparation tool for 1/2" LDF4-50A cable
Aluminum grounding kit stripping tool for LDF4 cable
Replacement blade kit for grounding kit stripping tool for
LDF4 cable
Manual cable preparation tool for 7/8" cable
Automated cable preparation tool for 7/8" cable
1-1/4" torque wrench for 7/8" connectors
1 -3/8" open end wrench for OnePiece
7/8" connectors, ts body of Positive Stop connectors
1-1/4" open end wrench for 7/8" connectors, ts
clamping nut of Positive Stop connectors
Aluminum grounding kit stripping tool for 7/8" cable
Replacement blade kit for plastic grounding kit stripping
tool for 7/8" cable
Tool Part Number
TB-COMP-KIT
*MCPT-1412
224361
224362
244494
MCPT-3812
224361
224362
244494
CPT-F4
MCPT-1412
241953
224361
224362
244394
CPT-L4ARC1
247696
245154
MCPT-L4
GKT-L4A
GKT-BK512
*MCPT-78
CPT-78U
244378
245516
244459-5
GKT-78A
GKT-BK512
Cable Size
General Purpose
1/4"
3/8"
1/2" F4
F4 and L4
1/2" L4
7/8"
Attachment Tool Kits
Easier Connections
The connector interface is one of the most critical
factors affecting transmission line operation. Even
experienced technicians can have a hard time when
equipped with makeshift devices or an inadequate
array of simple hand tools, and it only takes a single
faulty connection to degrade performance and
threaten your operations revenues.
Selection
The table is designed to help you select the right
tools for each cable size. Under each cable size you
will find a list of part numbers for the appropriate
cable preparation tools, cable conditioning tools,
spanner and torque wrenches, and grounding kit
preparation tools.
Youll have the option of selecting a manual or
automated cable preparation tool. Under the indi-
vidual tools you will find the torque wrenches for the
connector interface nuts.
*This tool is included in the complete tool kit box, TB-COMP-KIT.
Cable Installation Accessories
Installation Aids
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 28
Description
Manual cable preparation tool for 1-1/4" cable
Replacement blade for CPTV2-114
Automated cable preparation tool for 1-1/4" LDF6 cable
1-7/8" torque wrench 1-1/4" standard or RingFlare connectors
1-3/4" torque wrench for 1-1/4" OnePiece connectors
Aluminum grounding kit stripping tool for 1-1/4" cable
Replacement blade kit for grounding kit stripping tool for 1-1/4" cable
1-7/8" open end wrench
Manual cable preparation tool for 1-5/8" cable
Replacement blade for CPTV2-158
Automated cable preparation tool for 1-5/8" cable
2-1/4" torque wrench for 1-5/8" connectors
2-1/4" open end wrench for 1-5/8" connectors
Aluminum grounding kit stripping tool for 1-5/8" cable
Replacement blade kit for grounding kit stripping tool for 1-5/8" cable
Type N coupling nut torque wrench
7-16 DIN coupling nut torque wrench
Safety knife
Ruler
Grease brush
Point le
Pin alignment tool
Cable are tool LDF4
Cable are tool LDF5
Cable are tool LDF6
Pin depth gauge, Type N male
Pin depth gauge, Type N female
Pin depth gauge, 716 DIN male
Pin depth gauge, 716 DIN female
Tool Part Number
CPTV2-114
CPTV2-BK
CPTL6
244375
247698
GKT-114A
GKT-BK67
244459-6
CPTV2-158
CPTV2-BK
CPT-158U
244374
244459-7
GKT-158A
GKT-BK67
244379
244377
*224352
*224354
*224355
*224356
*224360
*224363
*224368
*224373
*224380
*224395
*114468
*114469
Cable Size
1-1/4" cable
1-5/8"
Individual Tools
*This tool is included in the complete tool kit box, TB-COMP-KIT.
L
I
G
H
T
N
I
N
G
P
R
O
T
E
C
T
I
O
N
( Grounding Kits
( Grounding Bars
( Surge Arrestors
Lightning Protection
Grounding Kits
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 30
Grounding
Point 1
Grounding Point 4
(Runs longer than 200 ft)
Grounding
Point 2
Grounding
Point 3
Transmission Line Grounding
A well designed system uses grounding kits to provide a bond
between the cable and the tower/earth ground system. One
grounding kit is recommended at tower top, tower bottom, at 200
ft (60 m) intervals (where applicable), and at the entrance to the
equipment shelter. Andrew solid copper grounding kits have passed
United States Air Force lightning simulation tests and meet MIL-STD-
188-124A. The non-braided solid copper construction of all Andrew
grounding kits eliminates corrosion caused by moisture retention and
wicking. A heat shrink tube protects the cable terminal connection.
( Compact SureGround ( SureGround ( Standard
Grounding Kit Selection
Several grounding kit options are available to meet the requirements
of any transmission line grounding application.
d
Compact SureGround grounding kits provide the fastest,
easiest installation with the highest degree of lightning protection.
Their self-sealing design clips and locks onto the cable in less
than a minute.
d
SureGround grounding kits, an industry favorite, offer clip on
attachment with taped weatherproofing.
d
Standard grounding kits provide the best grounding solution for
elliptical waveguide. The copper grounding strap is coiled around
the cable and weatherproofed with tape.
d
Universal grounding kits can be applied to a broad range of coaxial
or elliptical transmission lines.
Grounding Kit Selection Guide
Compact SureGround SureGround Standard Universal
Key Feature Over-molded weatherproof Preformed clip-on strap Wraparound grounding strap Multiple cable size
design for easy, fast installation wraparound grounding strap
Benets Uniform installation compact Requires no tools Fits standard coaxial cable Breakaway design ts
design for bundled installation for installation and elliptical waveguide multiple sizes of coaxial
cable and elliptical waveguide
Installation Time Less than 1 minute About 3 minutes About 6 minutes About 7 minutes
Construction Preformed copper Pre-tensioned copper Copper grounding strap Copper grounding strap
grounding strap grounding clip
Over-molded weatherproof Standard weatherproong Standard weatherproong Standard weatherproong
boot, locking bail
Heavy Duty Ground Lead
Andrew grounding kits use heavy duty 6 gauge ground leads
to maximize performance. The MIL-STD-188-124B compliant copper
ground lead reduces dc resistance. The extremely pliable jacket provides
protection and makes it easy to maneuver the lead into position for
attachment to the down conductor.
d
Solid copper construction for high current handling capability,
compatibility with copper cable outer conductors
d
Meets military standards at commercial prices.
d
Provides certainty of continued operation, tested at an
independent laboratory
Lightning Protection
Grounding Kits
31 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com
NEW! Compact SureGround
Grounding Kits
Now wireless communications system installers and designers can
protect their systems from the effects of lightning easier and at lower
cost. The new Compact SureGround grounding kit, available only from
Andrew, is a one-piece grounding assembly with the weatherproofing
molded right into the grounding strap.
Compact SureGround grounding kit features:
Easy attachment
d
Self-locking, self-sealing weatherproof enclosure eliminates
loose hardware and taping
d
Saves up to an hour of installation time per typical nine run site
Sure protection
d
Largest surface contact area in the industry
d
Provides surety of protection against even the most severe
lightning strikes
d
Waterproof to IEC529, IP68
Compact size
d
Clip and lock installation ideal for tight cable bundles
or crowded towers
d
Exclusive universal grounding lug can be fitted to a
one- or two-hole earthing attachment point.
United States Patent: 6,548,762. Other patents pending.
More Information
d
See Compact Sureground ordering information on page 33
d
See the installation video at
www.andrew.com/products/trans_line/heliax/sureground.aspx
Easy Installation
Position Compact SureGround
grounding kit
Clip and lock
to seal
SureGround
Kits
Fast Installation, Complete Protection
Protect your equipment from the effects of lightning with SureGround
grounding kits. Meeting both MIL and IEC standards, the SureGround
self-securing ground strap eliminates the need for attachment tools and
provides protection against lightning strikes in excess of 100 kA. Quality
non-braided solid copper construction prevents moisture retention and
wicking, while a heavy duty 6 gauge, MIL-STD-188-124B compliant
copper ground lead maximizes performance. Installation is fast, easy,
and error-free. Grounding kits include a solid copper strap riveted to
the grounding wire, tower attachment hardware, and a two-part tape
weatherproofing system. Grounding kit versions are available with a tin
plating for compatability with aluminum cables.
United States Patent: 5,850,056.
The Compact SureGround Kit with integrated weatherproong is
the choice for the speediest installation, best t in tight locations,
and long-term protection.
TIP!
TIP!
Completed
Lightning Protection
Grounding Kits
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 32
Connector Grounding Kit for Mounting Rail
Part Number Description
CGT12 Connector grounding kit ts all F4 and L4 (except OnePiece)
series connectors
CGT58 Connector grounding kit ts all L4.5 and L5
standard connectors
CGT78 Connector grounding kit ts all L5, V5, A5, OnePiece,
and Positive Stop series connectors
CGT114 Connector grounding kit ts all L6 series connectors
CGT158 Connector grounding kit ts all L7 and V7
series connectors
CGT214 Connector grounding kit ts all L12 series connectors
40 mm x 22 mm x 17 mm
Universal Grounding Lugs
This grounding lug provides you with the option of a one-hole
configuration or two-hole configuration. Just break away the bottom
portion of the lug and this will give you your one-hole lug. This universal
lug will fit common buss bar configurations with two-hole spacings
of 0.750, 0.815, or 1.0 in. Designed to crimp on 6 gauge or 16 mm
2
grounding wire. Included on all grounding kits and available separately.
Part Number Description
245529-10 Universal grounding lug, kit of 10
207136-3 Grounding lug hardware kit
Standard Grounding Kits
Easy Installation for System Protection
Standard grounding kits are traditional solutions for lightning protection
and are also well suited for elliptical waveguide installations. One
grounding kit is recommended at the tower top, tower bottom, at 200 ft
(60 m) intervals, and at the entrance to the equipment shelter. Standard
grounding kits (204989 and 241088 series) require few steps to install
and include easy-to-follow instructions. Proper tensioning is ensured
by an expansion section that provides visual indication that the strap is
secured.
Series 204989 and 241088 kits include a solid copper strap riveted
to the grounding wire, coiling tool for proper tightening, universal
grounding lug, tower attachment hardware, and a two-part tape weath-
erproofing system. Field-attachable, crimp-on grounding lugs require a
crimping tool (not included).
For two bolt grounding
Snap off pre-scored
lug for one hole option
For one bolt grounding
Crimping Tool for SureGround
and Standard Grounding
The crimping tool is used to attach crimp-on lugs for standard and
SureGround series grounding kits. Not required for kits with factory
attached lugs.
Part Number Description
207270 Crimping tool, quantity 1
Universal Grounding Kit
Part Number Description
UG12158-15B4 1/2"1-5/8" EW180EW63 60" eld attached lug
Lightning Protection
Grounding Kits
33 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com
Compact SureGround
24 in 36 in 60 in
Size/Type 600 mm 1 meter 1.5 meters
factory attached lug eld attached lug
1/2" LDF4 black CSGL4-06B2 CSGL4-10B2 CSGL4-15B4
1/2" LDF4 gray CSGL4-06S2 CSGL4-10S2 CSGL4-15S4
7/8" black CSGL5-06B2 CSGL5-10B2 CSGL5-15B4
7/8" gray CSGL5-06S2 CSGL5-10S2 CSGL5-15S4
1-1/4" black CSGL6-06B2 CSGL6-10B2 CSGL6-15B4
1-1/4" gray CSGL6-06S2 CSGL6-10S2 CSGL6-15S4
1-5/8" black CSGL7-06B2 CSGL7-10B2 CSGL7-15B4
1-5/8" gray CSGL7-06S2 CSGL7-10S2 CSGL7-15S4
SureGround
) GK-SUNV
Universal Connector Grounding Kit
Part Number Description
244495 Universal connector grounding kit
Lightning Protection
Grounding Bars
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 34
Ground Buss Bars
Andrew offers a complete range of grounding buss bar sizes and hole
pattern configurations to accommodate just about any application.
Each grounding bar is made from 1/4 in solid copper bar stock and is
available with optional tin plating. Kits come complete with insulators,
stainless steel brackets, adapters, and hardware for mounting to a wall
or tower.
2" Ground Buss Bar Kits
Part Number Description
2" x 10" Ground Buss Bar Kits
Bare Copper
UGBKIT-0210 Universal ground buss bar kit, 1/4" x 2" x 10"
(6.4 mm x 50.8 mm x 254.0 mm)
with universal buss bar hardware kit
Tinned Copper
UGBKIT-0210-T Universal tinned ground buss bar kit, 1/4" x 2" x 10"
(6.4 mm x 50.8 mm x 254.0 mm)
with universal buss bar hardware kit
2" x 12" Ground Buss Bar Kits
Bare Copper
UGBKIT-0212 Universal ground buss bar kit, 1/4" x 2" x 12"
(6.4 mm x 50.8 mm x 304.8 mm)
with universal buss bar hardware kit
Tinned Copper
UGBKIT-0212-T Universal tinned ground buss bar kit, 1/4" x 2" x 12"
(6.4 mm x 50.8 mm x 304.8 mm)
with universal buss bar hardware kit
7/16" x 5/8"
(11.1 mm x 15.9 mm)
7/16"
(11.1 mm)
2" (50.8 mm)
1/2"
(12.7 mm)
3/4"
(19.1 mm)
10"
(254 mm)
7/16"
(11.1 mm)
12"
(304.8 mm)
2"
(50.8 mm)
1/2"
(12.7 mm)
2" x 14" Ground Buss Bar Kits
Bare Copper
UGBKIT-0214 Universal ground buss bar kit, 1/4" x 2" x 14"
(6.4 mm x 50.8 mm x 355.6 mm)
with universal buss bar hardware kit
Tinned Copper
UGBKIT-0214-T Universal tinned ground buss bar kit, 1/4" x 2" x 14"
(6.4 mm x 50.8 mm x 355.6 mm)
with universal buss bar hardware kit
2-1/2" Ground Buss Bar Kits
Part Number Description
2-1/2" x 12-1/2" Ground Buss Bar Kits
Bare Copper
UGBKIT-2 Universal ground buss bar kit, 1/4" x 2-1/2 x 12-1/2
(6.4 mm x63.5 mm x 317.5 mm)
with universal buss bar hardware kit
Tinned Copper
UGBKIT-2T Universal tinned ground buss bar kit,
1/4" x 2-1/2" x 12-1/2"
(6.4 mm x 63.5 mm x 317.5 mm)
with universal buss bar hardware kit
13/16"
(20.6 mm)
7/16"
(11.1 mm)
1-1/4" (31.8 mm)
1-3/8"
(34.9 mm)
12-1/2"
(317.5 mm)
1"
(25.4 mm)
1"
(25.4 mm)
2-1/2" (63.5 mm)
7/16"
(11.1 mm)
1/2"
(12.7 mm)
2" (50.8 mm)
14"
(355.6 mm)
3/4" (19.1 mm)
7/16" x 5/8"
(11.1 x 15.9 mm)
( UGBKIT
Lightning Protection
Grounding Bars
35 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com
2-1/2" x 19-1/2" Ground Buss Bar Kits
Bare Copper
UGBKIT Universal ground buss bar kit, 1/4" x 2-1/2" x 19-1/2"
(6.4 mm x 63.5 mm x 495.3 mm)
with universal buss bar hardware kit
Tinned Copper
UGBKIT-T Universal tinned ground buss bar kit, 1/4" x 2-1/2" x 19-1/2"
(6.4 mm x 63.5 mm x 495.3 mm)
with universal buss bar hardware kit
4" Ground Buss Bar Kits
Part Number Description
4" x 12" Ground Buss Bar Kits
Bare Copper
UGBKIT-0412 Universal ground buss bar kit, 1/4" x 4" x 12"
(6.3 mm x 101.6 mm x 304.8 mm)
with universal buss bar hardware kit
Tinned Copper
UGBKIT-0412-T Universal tinned ground buss bar kit, 1/4" x 4" x 12"
(6.3 mm x 101.6 mm x 304.8 mm)
with universal buss bar hardware kit
7/16"
(11.1 mm)
12"
(304.8 mm)
4" (101.6 mm)
1/2" (12.7 mm) 3/4" (19 mm)
7/16" x 5/8"
(11.1 mm x 15.9 mm)
7/16"
(11.1 mm)
13/16"
(20.6 mm)
2-1/2"
(63.5 mm)
1" (25.4 mm)
1-3/8" (34.9 mm)
19-1/2"
(495.3 mm)
1-1/4" (31.8 mm)
4" x 14" Ground Buss Bar Kits
Bare Copper
GBKIT-0414 Universal ground buss bar kit, 1/4" x 4" x 14"
(6.3 mm x 101.6 mm x 355.6 mm)
with universal buss bar hardware kit.
Tinned Copper
UGBKIT-0414-T Universal tinned ground buss bar kit, 1/4" x 4" x 14"
(6.3 mm x 101.6 mm x 355.6 mm)
with universal buss bar hardware kit.
(11.1 mm)
(355.6 mm)
(12.7 mm)
(12.7 mm)
4" (101.6 mm)
1-1/2" (38.1 mm)
(6.4 mm)
(11.1 mm x 15.9 mm)
( UGBKIT-0210
( UGBKIT-0412
Lightning Protection
Grounding Bars
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 36
4" x 20" Ground Buss Bar Kits
Bare Copper
UGBKIT-0420 Universal ground buss bar kit, 1/4" x 4" x 20"
(6.3 mm x 101.6 mm x 508.0 mm)
with universal buss bar hardware kit.
Tinned Copper
UGBKIT-0420-T Universal tinned ground buss bar kit, 1/4" x 4" x 20"
(6.3 mm x 101.6 mm x 508.0 mm)
with universal buss bar hardware kit.
4" x 24" Ground Buss Bar Kits
Bare Copper
UGBKIT-0424 Universal ground buss bar kit, 1/4" x 4" x 24"
(6.3 mm x 101.6 mm x 609.6 mm)
with universal buss bar hardware kit.
Tinned Copper
UGBKIT-0424-T Universal tinned ground buss bar kit, 1/4" x 4" x 24"
(6.3 mm x 101.6 mm x 609.6 mm)
with universal buss bar hardware kit.
7/16" x 5/8"
(11.1 mm x 15.9 mm)
7/16"
(11.1 mm)
4" (101.6 mm)
20"
(508 mm)
3/4"
(19 mm)
1-3/4"
(44.5 mm)
7/16" x 5/8"
(11.1 mm x 15.9 mm)
7/16"
(11.1 mm)
4" (101.6 mm)
20"
(508 mm)
3/4"
(19 mm)
1-3/4"
(44.5 mm)
Universal Arrestor Ground Bar Assembly
This pre-punched solid copper ground bar assembly simplifies mounting
and grounding of surge arrestors inside the building. Instead of relying
on individual wires or field-fabricated trapeze setups, the Andrew
universal arrestor ground bar assembly provides a uniform mounting
and grounding point for surge arrestors and grounding leads. The 1/8
in assembly uses three horizontal members that can be oriented flat
or upright and adjusted vertically as needed to accommodate various
surge arrestor types. Also included is a mounting kit that includes ceiling
brackets, insulators, threaded rod, and hardware.
d
Compatible with standard entry port sizes
d
Height-adjustable bars
d
Solid copper construction
d
Accepts bulkhead or bolt grounded surge arrestors
d
Accommodates one- and two-hole grounding lugs
d
Eliminates need for internal buss bar
Part Number Description
UGBA-DIN-36 Three 6-position ground bars punched for oversized
7-16 DIN mount arrestors (APTL and APT series) or
bolt-grounded arrestors
UGBA-36 Three 6-position ground bars punched for most
7-16 DIN, Type N or bolt-grounded arrestors
(Andrew APG and APM series arrestors)
UGBA-DIN-34 Three 4-position ground bars punched for oversized
7-16 DIN mount arrestors (APTL and APT series) or
bolt-grounded arrestors
UGBA-34 Three 4-position ground bars punched for most 7-16
DIN, Type N, or bolt-grounded arrestors (Andrew APG
and APM series arrestors)
Lightning Protection
Surge Arrestors
37 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com
T-Series
Dual Band
dc Pass
Dual Band
Replaceable
Gas Tube
dc Block Integrated Bias Tee
T-Series Surge Arrestors
Arrestor Plus
Surge Arrestors.
To understand QWS technology, one needs to understand lightning.
The lightning transient is characterized by a current waveform
with an 8-microsecond rise time (time to reach 90% of the peak
value) and a 20-microsecond decay time (time to decay to 50%
of the peak value). Peak currents can reach excessive values, but
50% of all strikes will reach values of only 18 kA. It is important
to remember that this is only a laboratory characterization of the
lightning transient, but it facilitates standardized testing techniques
for the industry. Figure 1 depicts an actual laboratory-generated
8/20 sec waveform that was used to evaluate Andrew surge
arrestors. For more detailed information regarding laboratory
generated surge waveforms, see IEC 60-2, ANSI-IEEE Std 4-1978,
and ANSI C62.1-1984.
The substantial energy associated with lightning transients has
frequency components near dc with components of decreasing
value of energy extending through 160 kHz.
The effectiveness of surge arrestors is characterized by the
throughput energy and the ability to withstand multiple surges.
These characteristics are readily measurable in a laboratory
equipped with the appropriate test equipment. Throughput energy
is a measure of the amount of energy passed through the output
of the device when the input of the device is subjected to a light-
ning transient waveform. The throughput energy can be calculated
from the residual voltage waveform using the relationship:
Figure 2 shows the residual output voltage present when an
APT Series Surge Arrestor was subjected to an actual 8/20 sec
waveform with a peak current of 20 kA. In this case, the residual
voltage was recorded across a 50 ohm load. The resulting
throughput energy was 72 microjoules. The objective of the surge
arrestor is to minimize the throughput energy to a manageable
level. Most microwave transmitters and receivers used in todays
wireless systems are capable of withstanding throughput energy
levels of 10 millijoules or less.
The ability to withstand multiple strikes is also an important
measure of surge arrestor merit. Multistrike ability is measured
by subjecting the QWS surge arrestors to repeated surges and
observing if the arrestors continue to properly function or show
Time (microseconds)
Figure 1
Time (microseconds)
Figure 2
Laboratory generated 8 x 20 sec lightning surge current waveform.
Peak current: 21 kiloamperes
Residual output voltage of an APT quarterwave stub surge arrestor
when subjected to an 8 x 20 sec current surge with peak current
of 20,000 amperes.
Appendix 1
Quarterwave Stub Surge Arrestors
41 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com
signs of degradation. No evidence of failure or degradation was
observed after subjecting the Andrew Arrestor Plus
surge arres-
tors to over 100 strikes at 50 kA peak current using an 8/20 sec
waveform. This level of reliability is essential in protecting todays
telecommunications systems from the potential of damaging light-
ning transients.
Arrestor Plus QWS surge arrestors are carefully designed and
tested to provide a low impedance path to ground for any lightning
induced transient energy present on the center conductor of the
transmission line. These surge arrestors are designed to withstand
multiple strikes of the most severe surges. The unique attributes
of QWS surge arrestors are made possible by careful design
and selection of the geometry and cross-sectional area of the
conductors that make up the shorting stub. QWS designs result in
extremely low throughput energy devices with true
multistrike ability.
When selecting a surge arrestor, the RF performance must be
considered. Characteristics that describe RF performance are
operating bandwidth, VSWR (return loss), insertion loss, maximum
average power, and passive intermodulation distortion.
The operating bandwidth of quarterwave shorted stubs is limited,
but Andrew Arrestor Plus QWS surge arrestors are designed to
accommodate the operating bandwidth requirements of todays
wireless telecommunications systems. Quarterwave shorted stubs
can be designed to accommodate up to 20% bandwidth. The
bandwidth characteristics of the surge arrestors is similar to that of
a bandpass filter: RF signals at the center of the band pass unat-
tenuated, while out-of-band signals (such as lightning transients)
are diverted harmlessly to ground.
Figure 3 shows the measured wideband S11 (return loss) of a
QWS surge arrestor. Note that in the band of interest, the S11
levels are typically -30 dB.
It is key to note that dc signals cannot be passed through the
device. When dc passing is required, as is often the case for tower
top active electronics, then it is strongly recommended to use
Andrew APG gas tube series surge arrestors. For more information
on APG gas tube series arrestors, see Appendix 2.
The lowest center frequency of operation is limited to approxi-
mately 400 MHz, while the highest center frequency is limited
by the cutoff frequency of the coaxial cable being used. Figure
4 shows a cross-sectional view of a QWS surge arrestor. The
lower operating frequency is limited due to the physical size of
the shorting stub. When the shorting stub reaches too long of a
physical length, the stub appears as an inductive load, resulting
in excessive residual voltages. Quarterwave shorted stubs can be
designed to accommodate systems operating as high as 12 GHz.
Frequency (MHz)
Figure 3
Figure 4
S11 vs Frequency for a QWS surge arrestor
In the operating bandwidth of the Arrestor Plus
QWS surge
arrestors, the RF performance characteristics are optimal. At the
operating frequencies of the Arrestor Plus, the insertion loss is less
than 0.1 dB, no more than adding a connector to the transmission
line path. Figure 5 shows the measured S21 (insertion loss) perfor-
mance of an APM type QWS surge arrestor. Note that in the band
of interest, the S21 levels are better than -0.05 dB.
The maximum average operating power of the Arrestor Plus QWS
surge arrestor is limited by the connector interface. The suggested
maximum average operating power for Type N connectors is 600
watts at 900 MHz. The suggested maximum average operating
power for 7-16 DIN connectors is 3000 watts at 900 MHz.
Exceeding these values can result in excessive temperature rise
and permanent damage to the device.
Intermodulation distortion (IMD) is a major concern in todays PCS,
cellular, ESMR, and other wireless systems. IMD is caused by
nonlinear effects within a device. For connectors, these nonlinear
effects can be caused by poor contact between internal surfaces,
plating with ferrous materials, such as nickel, or by oxide build up
between contact surfaces.
Appendix 1
Quarterwave Stub Surge Arrestors
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 42
Arrestor Plus
Impedance (ohms)
V rms per carrier (volts) = 28.284
V peak per carrier (volts):= 2
surge
arrestors with 90 volt gas tubes
VSWR
Figure 2
Derating of maximum average power due to VSWR
and applied dc bias for APG Arrestor Plus
surge
arrestors with 90 volt gas tubes
Derating of maximum average power due to VSWR
and applied dc bias for APG Arrestor Plus
surge
arrestors with 90 volt gas tubes
Derating of maximum average power due to VSWR
and applied dc bias for APG Arrestor Plus
surge
arrestors with 350 volt gas tubes
Appendix 2
Gas Tube Surge Arrestors
45 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com
Andrew Arrestor Plus
Cables 237409
Click-On Hangers 237397
Standard Hanger Kits 37378
Type 31766A Hanger Kits 17783
Hanger Kits 37321
Hoisting Grip and Cable Support Hangers SP30-45
Compact Angle Adapters 10140
Angle Adaptors (types 31768A, 243684, 243684-M) 237363
Hanger Spacing Guidelines TP-101619.1-EN
SnapStak Adapter for 3/8" Control Cable TP-100940-EN
Cable Tie 40417 TP-101085-EN
Hoisting Grip for 1/4" Data Cables 7540680
SnapStak Installation 237637
Tools
HELIAX
Coaxial Cable
Recommended maximum hanger spacings are tabulated below for
various wind speed and ice conditions. The recommendations are based
on guidelines stated in EIA Standard RS-222 and new wind tunnel and
vibration tests. They supersede those in previous Andrew catalogs.
Please refer to Andrew publication number TP-101619-EN available at
www.andrew.com for the most current recommendations.
These spacing recommendations assume that all hangers are properly
installed and tightened.
Installations in Typical Climates
Use the 125 mph (200 km/h), 1/2 in ice conditions, highlighted in red.
Severe or Mild Climates
Use the wind speed and ice conditions that most closely approximate the
expected worst case conditions for the local climate.
Appendix 6
Hanger Spacing Guidelines
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 50
Standard HangerMaximum Hanger Spacing
Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed 85 mph (137 km/h) 100 mph (160 km/h)
Radial Ice No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
2-1/4" LDF12-50A 42395A-4 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)
2-1/4" HJ12-50 42396A-4 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)
3" HJ8-50B 31766A-11 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
4" HJ11-50B 31766A-10 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
5" HJ9HP-50 33598-5 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
5" HJ9-50 33598-5 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed 125 mph (200 km/h) 150 mph (240 km/h)
Radial Ice
1/2" LDF4-50A 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" LDF4-75A 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HL4RP-50 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HJ4-50 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HLT4-50 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HT4-50 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HST4-50 43211A 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HS4RP-50 43211A 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" FSJ4-50B 43211A 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" FSJ4-75A 43211A 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
5/8" LDF4.5-50 42396A-9 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 3 (0.9)
5/8" HJ4.5-50 42396A-9 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 3 (0.9)
7/8" AVA5-50 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
7/8" LDF5-50A 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
7/8" AL5-50 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
7/8" HJ5-50 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
7/8" HJ5-75 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
7/8" HT5-50 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1-1/4" LDF6-50 42396A-1 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
1-5/8" AVA7-50 42396A-2 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-5/8" LDF7-50A 42396A-2 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-5/8" AL7-50 42396A-2 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-5/8" HJ7-50A 42396A-2 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
2-1/4" LDF12-50 42395A-4 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
2-1/4" HJ12-50 42396A-4 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
3" HJ8-50B 31766A-11 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
4" HJ11-50B 31766A-10 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
5" HJ9HP-50 33598-5 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
5" HJ9-50 33598-5 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
Note: Standard tower configuration spacing is 3 to 4 ft.
Appendix 6
Hanger Spacing Guidelines
51 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com
Snap-In HangerRecommended Maximum Hanger Spacing
Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed 85 mph (137 km/h) 100 mph (160 km/h)
Radial Ice No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
1/2" LDF4-50A SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" LDF4-75A SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" HL4RP-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" HJ4-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" HLT4-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" HT4-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" HST4-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" HS4RP-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" FSJ4-50B SSH-12 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 2 (0.6)
1/2" FSJ4-75A SSH-12 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 2 (0.6)
5/8" LDF4.5-50 206706A-6 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
5/8" HJ4.5-50 206706A-6 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
7/8" AVA5-50 SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
7/8" LDF5-50A SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
7/8" AL5-50 SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
7/8" HJ5-50 SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
7/8" HJ5-75 SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
7/8" HT5-50 SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-1/4" LDF6-50 SSH-114 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-5/8" AVA7-50 SSH-158 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-5/8" LDF7-50A SSH-158 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-5/8" AL7-50 SSH-158 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-5/8" HJ7-50A SSH-158 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
2-1/4" LDF12-50 206706A-6 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6)
2-1/4" HJ12-50 206706A-6 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6)
Definitions and Assumptions 1. Per EIA-222 Standard: Coefficient of drag for coaxial cable is 1.2 (cylindrical members). Ice forms completely around member (360 degrees).
Combined wind and ice loading is reduced by 25% to reflect lower probability of wind and ice occurring simultaneously. 2. Wind speeds are maximum, which includes gust factors
and exposure factors. Note: Standard tower configuration spacing is 3 to 4 ft.
Appendix 6
Hanger Spacing Guidelines
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 52
Snap-In HangerRecommended Maximum Hanger Spacing
Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed 125 mph (200 km/h) 150 mph (240 km/h)
Radial Ice
1/2" LDF4-50A SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" LDF4-75A SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HL4RP-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HJ4-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HLT4-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HT4-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HST4-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HS4RP-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" FSJ4-50B SSH-12 3 (0.9) 2 (0.6) 1 (0.3) 2 (0.6) 2 (0.6) 1 (0.3)
1/2" FSJ4-75A SSH-12 3 (0.9) 2 (0.6) 1 (0.3) 2 (0.6) 2 (0.6) 1 (0.3)
5/8" LDF4.5-50 206706A-6 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6) 1 (0.3)
5/8" HJ4.5-50 206706A-6 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6) 1 (0.3)
7/8" AVA5-50 SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
7/8" LDF5-50A SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
7/8" AL5-50 SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
7/8" HJ5-50 SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
7/8" HJ5-75 SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
7/8" HT5-50 SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
1-1/4" LDF6-50 SSH-114 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
1-5/8" AVA7-50 SSH-158 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
1-5/8" LDF7-50A SSH-158 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
1-5/8" AL7-50 SSH-158 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
1-5/8" HJ7-50A SSH-158 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
2-1/4" LDF12-50 206706A-6 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
2-1/4" HJ12-50 206706A-6 2 (0.6) 2 (0.6) 1 (0.3) 2 (0.6) 1 (0.3) 1 (0.3)
No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
Definitions and Assumptions 1. Per EIA-222 Standard: Coefficient of drag for coaxial cable is 1.2 (cylindrical members). Ice forms completely around member (360 degrees).
Combined wind and ice loading is reduced by 25% to reflect lower probability of wind and ice occurring simultaneously. 2. Wind speeds are maximum, which includes gust factors
and exposure factors. Note: Standard tower configuration spacing is 3 to 4 ft.
Appendix 6
Hanger Spacing Guidelines
53 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com
Click-On HangerRecommended Maximum Hanger Spacing
Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed 85 mph (137 km/h) 100 mph (160 km/h)
Radial Ice
1/2" LDF4-50A L4CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
1/2" LDF4-50A L4CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
1/2" LDF4-50A L4CLICK, 3 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
Note: These same hanger spacing recommendations apply for the other following 1/2 in cable types: LDF4-75A, HL4RP-50, HLT4-50, HS4RP-50, HST4-50, HT4-50, HJ4-50
5/8" LDF4.5-50A L45CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
5/8" LDF4.5-50A L45CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
5/8" LDF4.5-50A L45CLICK, 3 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
Note: These same hanger spacing recommendations apply for the other following 5/8 in cable types: HJ4.5-50
7/8" LDF5-50A L5CLICK, 1 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)
7/8" LDF5-50A L5CLICK, 2 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)
7/8" LDF5-50A L5CLICK, 3 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)
Note: These same hanger spacing recommendations apply for the other following 7/8 in cable types: AVA5-50, VXL5-50, AL5-50, HJ5-50, HJ5-75, HT5-5
1-1/4" LDF6-50 L6CLICK, 1 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)
1-1/4" LDF6-50 L6CLICK, 2 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)
1-1/4" LDF6-50 L6CLICK, 3 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
1-5/8" LDF7-50A L7CLICK, 1 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)
1-5/8" LDF7-50A L7CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
1-5/8" LDF7-50A L7CLICK, 3 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
Note: These same hanger spacing recommendations apply for the other following 1 5/8 in cable types: HJ7-50A, AVA7-50, AL7-50
* These hanger spacings have been specified based on using the Click-On Hangers with Andrew specified hardware kits.
(Note: Standard tower configuration spacing is 3 to 4 ft)
Definitions and Assumptions 1. Per EIA-222 Standard: Coefficient of drag for coaxial cable is 1.2 (cylindrical members). Ice forms completely around member (360 degrees).
Combined wind and ice loading is reduced by 25% to reflect lower probability of wind and ice occurring simultaneously. 2. Wind speeds are maximum, which includes gust factors
and exposure factors.
Appendix 6
Hanger Spacing Guidelines
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 54
Click-On HangerRecommended Maximum Hanger Spacing
Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed 125 mph (200 km/h) 150 mph (240 km/h)
Radial Ice
1/2" LDF4-50A L4CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
1/2" LDF4-50A L4CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
1/2" LDF4-50A L4CLICK, 3 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6
No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
Note: These hanger spacing recommendations are also applicable for these 1/2 in cable types: LDF4-75A, HL4RP-50, HLT4-50, HS4RP-50, HST4-50, HT4-50, HJ4-50
5/8" LDF4.5-50A L45CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
5/8" LDF4.5-50A L45CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
5/8" LDF4.5-50A L45CLICK, 3 Stack 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6)
Note: These hanger spacing recommendations are also applicable for this 5/8 in cable type: HJ4.5-50
7/8" LDF5-50A L5CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
7/8" LDF5-50A L5CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
7/8" LDF5-50A L5CLICK, 3 Stack 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6)
Note: These hanger spacing recommendations are also applicable for these 7/8 in cable types: AVA5-50, VXL5-50, AL5-50, HJ5-50, HJ5-75, HT5-5
1-1/4" LDF6-50 L6CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
1-1/4" LDF6-50 L6CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
1-1/4"
1-5/8" LDF7-50A L7CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
1-5/8" LDF7-50A L7CLICK, 2 Stack 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6)
1-5/8" LDF750A L7CLICK, 3 Stack 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6)
LDF6-50 L6CLICK, 3 Stack 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6)
Note: These hanger spacing recommendations are also applicable for these 1 5/8 in cable types: HJ7-50A, AVA7-50, AL7-50
(Note: Standard tower configuration spacing is 3 to 4 ft)
Mini Click-On HangerRecommended Maximum Hanger Spacing
Cable Size Cable Part Number Hanger Part Number
Wind Speed 125 mph (200 km/h)
Radial Ice
6 mm8mm CNT-240, CNT-300, FSJ1 series 68MCLICK, 1 Stack 1.5 (0.61) 1.5 (0.61) 1.5 (0.61)
6 mm8mm CNT-240, CNT-300, FSJ1 series 68MCLICK, 2 Stack 1.5 (0.61) 1.5 (0.61) 1.5 (0.61)
6 mm8mm
9 mm12 mm CNT-400, LDF1, FSJ2, LDF2, EFX2 series 912MCLICK, 1 Stack 3.0 (0.90) 3.0 (0.90) 3.0 (0.90)
9 mm12 mm CNT-400, LDF1, FSJ2, LDF2, EFX2 series 912MCLICK, 2 Stack 3.0 (0.90) 3.0 (0.90) 3.0 (0.90)
9 mm12 mm
13 mm16 mm CNT-500, CNT-600, FSJ and LDF4 series 1316MCLICK, 1 Stack 3.0 (0.90) 3.0 (0.90) 3.0 (0.90)
13 mm16 mm CNT-500, CNT-600, FSJ and LDF4 series 1316MCLICK, 2 Stack 3.0 (0.90) 3.0 (0.90) 3.0 (0.90)
13 mm16 mm CNT-500, CNT-600, FSJ and LDF4 series 1316MCLICK, 3 Stack 2.0 (0.60) 2.0 (0.60) 2.0 (0.60)
CNT-400, LDF1, FSJ2, LDF2, EFX2 series 912MCLICK, 3 Stack 2.0 (0.60) 2.0 (0.60) 2.0 (0.60)
CNT-240, CNT-300, FSJ1 series 68MCLICK, 3 Stack 1.5 (0.61) 1.5 (0.61) 1.5 (0.61)
No Ice 1/2" (13 mm) 1" (25 mm)
Definitions and Assumptions 1. Per EIA-222 Standard: Coefficient of drag for coaxial cable is 1.2 (cylindrical members). Ice forms completely around member (360 degrees).
Combined wind and ice loading is reduced by 25% to reflect lower probability of wind and ice occurring simultaneously. 2. Wind speeds are maximum, which includes gust factors
and exposure factors. Note: Standard tower configuration spacing is 3 to 4 ft.
Appendix 6
Hanger Spacing Guidelines
55 Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com
Standard Hanger for HELIAX
Elliptical Waveguide
Recommended maximum hanger spacings are tabulated below for
various wind speed and ice conditions. The recommendations are based
on guidelines stated in EIA Standard RS-222 and new wind tunnel and
vibration tests. They supersede those in previous Andrew catalogs.
Installations in Typical Climates
Use the 125 mph (200 km/h), 1/2 in ice conditions, highlighted in red.
Severe or Mild Climates
Use the wind speed and ice conditions that most closely approximate the
expected worst case conditions for the local climate.
Appendix 6
Hanger Spacing Guidelines
Andrew Corporation phone 1.800.255.1479 1.708.873.2307 fax 1.800.349.5444 1.779.435.8579 www.andrew.com 56
Standard Hanger for HELIAX