Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

V2224G-OP DataSheet English 120927

Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

Datasheet

V2224G-OP
Version 1.1

Data Sheet
V2224G-OP

Issue History
Version

Date of Issue

Reason for Update

V1.0

04/2012

Initial release

V1.1

09/2012

Issue 2
- product picture added
- optional uplink modules added.
- removes the features not supported. (ERP, VLAN translation)
- switching capacity, throughput, operating temperature updated.
- dual DC power type removed.

v1.1

Page 2 of 14

Data Sheet
V2224G-OP

1 Product Overview
Dasan Networks V2224G-OP is one RU height single-board Layer 2 Gigabit Ethernet
switch which has been designed as ultra-compact customer premise equipment.
The V2224G-OP provides 24-port of 100/1000Base-X interfaces (SFP) with two mounting
slots for the optional uplink modules. It also has a non-blocking architecture and interfaces
providing wire-speed and full-duplex packet traffic on all ports. For the uplink interface unit,
there are 1-Port 1000Base-X (SFP) / E-PON / 10GBase-R (SFP+) and 2-Port 1000Base-X
(SFP) modular type unit. Each uplink module can be inserted into two front slots.
The console interface is located on the most left of the front panel with embedded LED for
TX/RX indication. It is for use of equipment management via remote access or CLI.
It is an effective product to network environment of entry-level enterprise, mid-market and
branch office networks, a large scale place of business and ISP (Internet Service Provider)
to support high-speed internet service than existing Ethernet products. It offers flexible interface to make up diversity network services and benefit of network extension.
The V2224G-OP is a non-blocking Layer 2 gigabit switch which helps to eliminate network
traffic bottlenecks. Once more, Link aggregation via IEEE 802.3ad allows administrators to
group any number of copper or fiber ports together to form an ultra-high bandwidth pipe
that greatly expands bandwidth capacity to the network backbone.
Depending on a type of optional uplink modules, the V2224G-OP can be used as E-PON
Optical Network Unit (ONU)/Multi Dwelling Unit (MDU).
The PON technology adds new features and functionality targeted at improving performance and interoperability, and adds support for new applications, services, and deployment scenarios. Among these changes are improvements in data rate and reach performance, diagnostics, and stand-by mode, to name a few.
The V2224G-OP introduces a point-to-multipoint concept with the PON technology, which
enables a cost-effective FTTx service. The reason why PON is considered as a costeffective solution is its usage of a passive splitter rather than an active switching system.
The benefits of the passive splitter are as follows:
No power supply / maintenance is needed.
The splitter does not need any fiber optic transceiver. The number of fiber optic
transceivers in the network is minimized.

v1.1

Page 3 of 14

Data Sheet
V2224G-OP

Figure 1

Front View of V2224G-OP

Name

MGMT
CONSOLE

Function

Connector Type

Out-of-band TMN-OS Interface

RJ45

CLI access to configure the functions for

RJ45 (RS232)

system operation

Service GE i/f
Uplink i/f slot

24 x 100/1000Base-X interfaces

SFP

2 x Mounting slots for optional uplink unit

1 Port of 1000Base-X (SFP)


E-PON (10km, SC/PC-type)
10GBase-R (SFP+)
2-Port of 1000Base-X (SFP)

Table 1

Front Access Interfaces of V2224G-OP

The V2224G-OP provides a fixed single power supply connector (AC type or DC type) on
the rear panel, so you can choose proper power supply according to installation environment. The power is supplied to the switch through DC/DC or AC/DC converter located in
the switch which converts the input power to the proper voltages.

v1.1

Page 4 of 14

Data Sheet
V2224G-OP

v1.1

Figure 2

Rear View of V2224G-OP (Single AC power type)

Figure 3

Rear View of V2224G-OP (Single DC power type)

Page 5 of 14

Data Sheet
V2224G-OP

1.1

LEDs on V2224G-OP

Figure 4

Label
RUN

PWR

FAN

RS232

LEDs on the V2224G-OP

Color
Green

Description

On

The system is starting up to boot.

Blinking

The system is running with no errors.

Off

The system is turned off.

Amber

Blinking

CPU load is high.

Green

On

Power is supplied in the normal operating condition.

Off

Power supply is failed.

On

FAN is in the normal operating condition.

Off

FAN is failed.

Green

Blinking

A transmit activity is present on the console.

TX

Off

No transmit activity is present on the console.

RS232

Blinking

A receive activity is present on the console.

RX

Off

No receive activity is present on the console.

On

Link is up

Off

Link is down

On

A transmit or receive activity is present on the MGMT interface.

Off

No transmit or receive activity is present on the MGMT interface.

MGMT

Green

Green

LNK
MGMT

Amber

ACT

Table 2

Label
LNK/ACT
(Port 1-24)

Table 3

v1.1

Status

Operating Status LEDs on the V2224G-OP

Color
Green

Status

Description

On

Link Up

Blinking

A transmit or receive activity is present on the network interface.

Off

Link Down

Link Status LEDs on Optical GE Interface

Page 6 of 14

Data Sheet
V2224G-OP

1.2

FTTx Service Scenario


PON & Optical Distribution Network
A PON consists of an Optical Line Termination (OLT) located at the Central Office and a set
of Multi Dwelling Units (MDUs)/Optical Network Units (ONUs) or Optical Network Terminals
(ONTs) located at the customers premises. Between them is the Optical Distribution Network (ODN) comprising of fibers and passive optical splitters or couplers. A splitter is a device that divides an optical signal into two or more signals. OLT connects the PON to the IP
network, controls and manages the PON clients. MDU connects the user specific network
to PON. The ONT can be occupied by a single subscriber and also can be a gateway of the
local network.

Figure 5

Optical Distribution Network by PON Architecture

E-PON MDU
When you install the E-PON uplink module into a slot on the V2224G-OP, this system can
be used as E-PON MDU for FTTB (fiber to the Building) deployment. The E-PON MDU system is one element of PON network solution. Depending on the subscriber type and desired topology to the network, the operator may adopt: FTTH (fiber to the Home) and FTTB
(fiber to the Building).

Figure 6

v1.1

FTTx Service Deployments

Page 7 of 14

Data Sheet
V2224G-OP

2 Product Specification
2.1

System Feature
The V2224G-OP supports the following system features:

2.2

88 Gbps switching capacity and 65.5 Mpps throughput


24 subscriber interface ports
24-Port 100/1000Base-X Gigabit Ethernet i/f
2 optional expansion slots for uplink modules
- 1000Base-X (SFP) 1-Port uplink module per slot
- 1000Base-X (SFP) 2-Port uplink module per slot
- E-PON (SC/PC-type, 10km) 1-Port uplink module per slot
- 10GBase-R (SFP+) 1-Port uplink module per slot
LED indicators
Console command line interface (CLI) via RS232
Out-of-band management via 10/100Base-TX
Fixed fans for internal cooling

Functionalities
Layer 2 Switch
Standard Ethernet Bridging
Managing 16K MAC addresses in MAC table
IEEE 802.1Q tagged frame supporting 4K VLANs
Port/MAC/Subnet/Protocol-based VLAN
VLAN stacking
Independent VLAN learning (IVL)
Spanning tree (STP/RSTP/MSTP/PVSTP/PVRSTP)
802.3ad link aggregation
Port mirroring
Flow control
Jumbo frame support
FTTx deployments for various applications with PON uplink interfaces
Multicast
IGMP v1/v2/v3
IGMP snooping
MVR
QoS
Rate limiting
Diff Serv
Traffic scheduling (SP, WRR, DRR)
Four queues per port

v1.1

Page 8 of 14

Data Sheet
V2224G-OP

Security
SSH v1/v2
RADIUS, TACACS+ Authentication
MAC/port based authentication according to 802.1x
Ethernet type / L4-based ACL (Access Control List)
Storm Control
DHCP Filtering
MAC Filtering
Management
Serial/Telnet (CLI)
SNMPv1/v2/v3
DHCP server, relay agent with option82
RMON
Syslog
Software Download/ Upgrade
Configuration Download/ Upload
DNS

E-PON MDU Features (optional uplink i/f)


The following table shows the key features of E-PON uplink module of V2224G-OP:
Ethernet PON ONU/MDU based on IEEE802.3ah standard
Fiber Transceiver (SFF SC/PC Type)
Support the following data rates:
- 1.25 Gbps (Downstream/Upstream)
Support 1000Base-PX10
128 bit AES encryption-upstream and downstream
QoS support: IP ToS classification and VLAN/LLID prioritization
Advanced classification engine with support for VLAN, IP, TCP & UDP to provide true
triple-play services
Advanced threshold and queue level reporting to support high quality of service DBA
algorithms

v1.1

Page 9 of 14

Data Sheet
V2224G-OP

2.3

Physical Specification
Mechanics
Dimensions (W x H x D)
Minimum free space above shelf
Minimum free space below shelf
Operating Temperature
Storage Temperature
Operating Humidity Range

440 x 44 x 300 mm (17.3 x 1.7 x 11.8 in)


50 mm
25 mm
-4 ~ 140F (-20 ~ 60C)
-40~158 F (-40 ~ 70C)
0% to 90% Non-condensing

Power Supply
AC power voltage (Single AC)
DC power voltage (Single DC)
Power Consumption

100-240VAC, 50/60Hz
-48/60VDC
37W

Operating Indicators
System LEDs
Service Optical GE i/f LEDs
Uplink i/f LEDs
Console
MGMT

RUN, PWR, FAN


LNK / ACT
LNK / ACT
RX, TX
LNK / ACT

Interface Parameter

v1.1

Gigabit Ethernet i/f


Uplink i/f Slots
(1-port module per slot)

24 x 100/1000Base-X (SFP)
2 x 1-Port 1000Base-X (SFP)
E-PON (SC/PC-type)
10GBase-R (SFP+)
2-Port 1000Base-X (SFP)

Ethernet i/f for local management


Serial i/f, Console

10/100Base-TX
1-Port (RS232)

Page 10 of 14

Data Sheet
V2224G-OP

3 Uplink Module & Connector Specification


3.1

Uplink Interface Options


The following different uplink modules are available and can be inserted into the dedicated
slots. Each uplink module contains one port.
Uplink Module

Description

1SFPM-1G-S

1-Port 1G SFP Uplink Module

1GPM-10(T)-A

1-port GE-PON (PX10U, SC/PC-type, IEEE802.3ah) service interface


(Teknovus) for V2724G
-. LD Shutdown, Remote Reset

1GPM-10(P)-A

1-port GE-PON (PX10U, SC/PC-type, IEEE802.3ah) service interface (PMCSierra) for V2724G
-. LD Shutdown, Remote Reset

2SFPM-S

2-Port SFP Uplink Module DDM (Digital Diagnostic Monitoring) support for
V2224G
- 100/1000Base-X SFP

1SFPXM

1-Port SFP+ Uplink Module DDM (Digital Diagnostic Monitoring) support for
V2208G, V2216G, V2224G
- 10GBase- R SFP+

Uplink Blank Panel

Table 4

v1.1

Uplink Blank Panel

Uplink Modules

Other types of uplink module can be also available upon customer request.

Figure 7

1G SFP uplink modules

Figure 8

E-PON uplink modules

Page 11 of 14

Data Sheet
V2224G-OP

Figure 9

3.2

10GbE SFP+ uplink module

E-PON ONU Optical Transceiver


The followings are the features of E-PON MDU/ONU Transceiver.

Optical
Connector
SC/PC

Table 5

Package

SFF

RoHS compliant

IEEE802.3ah Gigabit Ethernet compliant

SFF package with SC Receptacle

1310nm Burst Mode 1.25Gbps transmitter, and 1490nm Continuous Mode 1.25Gbps receiver

Integrated with WDM filter to cut 1550nm and 1650nm optical signal off

Single +3.3V power supply

LVPECL electrical signal interface, LVTTL Bias Control input and Rx Signal Detect output

Laser Class 1 Product which comply with the requirements of IEC 60825-1 and IEC 60825-2

Rx

Wavelength

Data Rate

1310 nm (TX)

1.25Gb/s US

1490 nm (RX)

1.25Gb/s DS

Saturation Optical power

sensitivity
< -26dBm

Optical

Reach

Tx Power
> -3dBm

-0.5 ~ +4.5dBm

10 km

Specification of E-PON ONU transceiver

3.3

SFP Options
The following different optical SFP modules are available and can be inserted into the dedicated modules.
SFP Module
SFP-GE-SX

Description
SFP GE SX
- Wavelength: 850 nm / Distance: 550 m / Mode: multi-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 C ~ 70 C

SFP-GE-LX10

SFP GE LX10
- Wavelength: 1310 nm / Distance: 10 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 C ~ 70 C

v1.1

Page 12 of 14

Data Sheet
V2224G-OP

SFP Module
SFP-GE-LX20

Description
SFP GE LX20
- Wavelength: 1310 nm / Distance: 20 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 C ~ 70 C

SFP-GE-LX40

SFP GE LX40
- Wavelength: 1310 nm / Distance: 40 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0C ~ 70 C

Table 6

i
3.4

SFP Modules

Other types of SFP module can be also available upon customer request.

SFP+ Options
The following different optical SFP+ modules are available and can be inserted into the
dedicated modules.
SFP+ Module
SFPP-10GE-SR

Description
SFP+ 10GE SR
-. Wavelength : 850nm / Distance : 300m / Mode : Multimode
-. Connector: LC / Data rate: 10.3125 Gbit/s / Core type: Dual Core
-. Tx Power: -5 ~ -1 dBm, Rx sensitivity: -11.1 dBm
-. Operating Temperature : 0C ~ 70 C
-. 10GBASE-SR (10G)

SFPP-10GE-LR

SFP+ 10GE LR
-. Wavelength : 1310nm / Distance : 10Km / Mode :Singlemode
-. Connector : LC / Data rate : 10.3125 Gbit/s / Core type : Dual Core
-. Tx Power: -8.2 ~ +0.5 dBm, Rx sensitivity: -12.6 dBm
-. Operating Temperature : -5C ~ 70 C
-. 10GBASE-LR (10G)

SFPP-10GE-ER

SFP+ 10GE ER
-. Wavelength : 1550nm / Distance : 40Km / Mode :Singlemode
-. Connector : LC / Data rate : 10.3125 Gbit/s / Core type : Dual Core
-. Tx Power: -4.7 ~ +4.0 dBm, Rx sensitivity: -14.1 dBm
-. Operating Temperature : 0C ~ 70 C
-. 10GBASE-ER (10G)

SFPP-10GE-ZR

SFP+ 10GE ZR
-. Wavelength : 1310nm / Distance : 70Km / Mode :Singlemode
-. Connector : LC / Data rate : 10.3125 Gbit/s / Core type : Dual Core
-. Tx Power: +3 ~ +6 dBm, Rx sensitivity: -22 dBm
-. Operating Temperature : 0C ~ 70 C
-. 10GBASE-ZR (10G)

Table 7

v1.1

SFP+ Modules

Page 13 of 14

Data Sheet
V2224G-OP

4 Ordering Information
Bases
V2224G-OP Fixed single AC power
Fixed 24-Port 100/1000Base-X, 2 modular uplink slot, 32MB Flash, and 256MB SDRAM, Fixed single AC power (SMPS), Uplink module & SFP compatible with V2724G
V2224G-OP Fixed single DC power
Fixed 24-Port 100/1000Base-X, 2 modular uplink slot, 32MB Flash, and 256MB SDRAM, Fixed single DC power (SMPS), Uplink module & SFP compatible with V2724G

Uplink Interface Options


1SFPM-1G-S, 1GPM-10(T)-A, 1GPM-10(P)-A, 2SFPM-S, 1SFPXM

SFP Options
SFP-GE-SX, SFP-GE-LX10, SFP-GE-LX20, SFP-GE-LX40

SFP+ Options
SFP+ 10GE-SR, SFP+ 10GE-LR, SFP+ 10GE-ER, SFP+ 10GE-ZR

DASAN Networks
DASAN Tower, 49, Daewangpangyo-ro644Beon-gil, Bundang-gu, Seongnam-si,
Gyeonggi-do, 463-400, KOREA Tel +82-70-7010-1000

www.dasannetworks.com

v1.1

Page 14 of 14

You might also like