V2224G-OP DataSheet English 120927
V2224G-OP DataSheet English 120927
V2224G-OP DataSheet English 120927
V2224G-OP
Version 1.1
Data Sheet
V2224G-OP
Issue History
Version
Date of Issue
V1.0
04/2012
Initial release
V1.1
09/2012
Issue 2
- product picture added
- optional uplink modules added.
- removes the features not supported. (ERP, VLAN translation)
- switching capacity, throughput, operating temperature updated.
- dual DC power type removed.
v1.1
Page 2 of 14
Data Sheet
V2224G-OP
1 Product Overview
Dasan Networks V2224G-OP is one RU height single-board Layer 2 Gigabit Ethernet
switch which has been designed as ultra-compact customer premise equipment.
The V2224G-OP provides 24-port of 100/1000Base-X interfaces (SFP) with two mounting
slots for the optional uplink modules. It also has a non-blocking architecture and interfaces
providing wire-speed and full-duplex packet traffic on all ports. For the uplink interface unit,
there are 1-Port 1000Base-X (SFP) / E-PON / 10GBase-R (SFP+) and 2-Port 1000Base-X
(SFP) modular type unit. Each uplink module can be inserted into two front slots.
The console interface is located on the most left of the front panel with embedded LED for
TX/RX indication. It is for use of equipment management via remote access or CLI.
It is an effective product to network environment of entry-level enterprise, mid-market and
branch office networks, a large scale place of business and ISP (Internet Service Provider)
to support high-speed internet service than existing Ethernet products. It offers flexible interface to make up diversity network services and benefit of network extension.
The V2224G-OP is a non-blocking Layer 2 gigabit switch which helps to eliminate network
traffic bottlenecks. Once more, Link aggregation via IEEE 802.3ad allows administrators to
group any number of copper or fiber ports together to form an ultra-high bandwidth pipe
that greatly expands bandwidth capacity to the network backbone.
Depending on a type of optional uplink modules, the V2224G-OP can be used as E-PON
Optical Network Unit (ONU)/Multi Dwelling Unit (MDU).
The PON technology adds new features and functionality targeted at improving performance and interoperability, and adds support for new applications, services, and deployment scenarios. Among these changes are improvements in data rate and reach performance, diagnostics, and stand-by mode, to name a few.
The V2224G-OP introduces a point-to-multipoint concept with the PON technology, which
enables a cost-effective FTTx service. The reason why PON is considered as a costeffective solution is its usage of a passive splitter rather than an active switching system.
The benefits of the passive splitter are as follows:
No power supply / maintenance is needed.
The splitter does not need any fiber optic transceiver. The number of fiber optic
transceivers in the network is minimized.
v1.1
Page 3 of 14
Data Sheet
V2224G-OP
Figure 1
Name
MGMT
CONSOLE
Function
Connector Type
RJ45
RJ45 (RS232)
system operation
Service GE i/f
Uplink i/f slot
24 x 100/1000Base-X interfaces
SFP
Table 1
The V2224G-OP provides a fixed single power supply connector (AC type or DC type) on
the rear panel, so you can choose proper power supply according to installation environment. The power is supplied to the switch through DC/DC or AC/DC converter located in
the switch which converts the input power to the proper voltages.
v1.1
Page 4 of 14
Data Sheet
V2224G-OP
v1.1
Figure 2
Figure 3
Page 5 of 14
Data Sheet
V2224G-OP
1.1
LEDs on V2224G-OP
Figure 4
Label
RUN
PWR
FAN
RS232
Color
Green
Description
On
Blinking
Off
Amber
Blinking
Green
On
Off
On
Off
FAN is failed.
Green
Blinking
TX
Off
RS232
Blinking
RX
Off
On
Link is up
Off
Link is down
On
Off
MGMT
Green
Green
LNK
MGMT
Amber
ACT
Table 2
Label
LNK/ACT
(Port 1-24)
Table 3
v1.1
Status
Color
Green
Status
Description
On
Link Up
Blinking
Off
Link Down
Page 6 of 14
Data Sheet
V2224G-OP
1.2
Figure 5
E-PON MDU
When you install the E-PON uplink module into a slot on the V2224G-OP, this system can
be used as E-PON MDU for FTTB (fiber to the Building) deployment. The E-PON MDU system is one element of PON network solution. Depending on the subscriber type and desired topology to the network, the operator may adopt: FTTH (fiber to the Home) and FTTB
(fiber to the Building).
Figure 6
v1.1
Page 7 of 14
Data Sheet
V2224G-OP
2 Product Specification
2.1
System Feature
The V2224G-OP supports the following system features:
2.2
Functionalities
Layer 2 Switch
Standard Ethernet Bridging
Managing 16K MAC addresses in MAC table
IEEE 802.1Q tagged frame supporting 4K VLANs
Port/MAC/Subnet/Protocol-based VLAN
VLAN stacking
Independent VLAN learning (IVL)
Spanning tree (STP/RSTP/MSTP/PVSTP/PVRSTP)
802.3ad link aggregation
Port mirroring
Flow control
Jumbo frame support
FTTx deployments for various applications with PON uplink interfaces
Multicast
IGMP v1/v2/v3
IGMP snooping
MVR
QoS
Rate limiting
Diff Serv
Traffic scheduling (SP, WRR, DRR)
Four queues per port
v1.1
Page 8 of 14
Data Sheet
V2224G-OP
Security
SSH v1/v2
RADIUS, TACACS+ Authentication
MAC/port based authentication according to 802.1x
Ethernet type / L4-based ACL (Access Control List)
Storm Control
DHCP Filtering
MAC Filtering
Management
Serial/Telnet (CLI)
SNMPv1/v2/v3
DHCP server, relay agent with option82
RMON
Syslog
Software Download/ Upgrade
Configuration Download/ Upload
DNS
v1.1
Page 9 of 14
Data Sheet
V2224G-OP
2.3
Physical Specification
Mechanics
Dimensions (W x H x D)
Minimum free space above shelf
Minimum free space below shelf
Operating Temperature
Storage Temperature
Operating Humidity Range
Power Supply
AC power voltage (Single AC)
DC power voltage (Single DC)
Power Consumption
100-240VAC, 50/60Hz
-48/60VDC
37W
Operating Indicators
System LEDs
Service Optical GE i/f LEDs
Uplink i/f LEDs
Console
MGMT
Interface Parameter
v1.1
24 x 100/1000Base-X (SFP)
2 x 1-Port 1000Base-X (SFP)
E-PON (SC/PC-type)
10GBase-R (SFP+)
2-Port 1000Base-X (SFP)
10/100Base-TX
1-Port (RS232)
Page 10 of 14
Data Sheet
V2224G-OP
Description
1SFPM-1G-S
1GPM-10(T)-A
1GPM-10(P)-A
1-port GE-PON (PX10U, SC/PC-type, IEEE802.3ah) service interface (PMCSierra) for V2724G
-. LD Shutdown, Remote Reset
2SFPM-S
2-Port SFP Uplink Module DDM (Digital Diagnostic Monitoring) support for
V2224G
- 100/1000Base-X SFP
1SFPXM
1-Port SFP+ Uplink Module DDM (Digital Diagnostic Monitoring) support for
V2208G, V2216G, V2224G
- 10GBase- R SFP+
Table 4
v1.1
Uplink Modules
Other types of uplink module can be also available upon customer request.
Figure 7
Figure 8
Page 11 of 14
Data Sheet
V2224G-OP
Figure 9
3.2
Optical
Connector
SC/PC
Table 5
Package
SFF
RoHS compliant
1310nm Burst Mode 1.25Gbps transmitter, and 1490nm Continuous Mode 1.25Gbps receiver
Integrated with WDM filter to cut 1550nm and 1650nm optical signal off
LVPECL electrical signal interface, LVTTL Bias Control input and Rx Signal Detect output
Laser Class 1 Product which comply with the requirements of IEC 60825-1 and IEC 60825-2
Rx
Wavelength
Data Rate
1310 nm (TX)
1.25Gb/s US
1490 nm (RX)
1.25Gb/s DS
sensitivity
< -26dBm
Optical
Reach
Tx Power
> -3dBm
-0.5 ~ +4.5dBm
10 km
3.3
SFP Options
The following different optical SFP modules are available and can be inserted into the dedicated modules.
SFP Module
SFP-GE-SX
Description
SFP GE SX
- Wavelength: 850 nm / Distance: 550 m / Mode: multi-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 C ~ 70 C
SFP-GE-LX10
SFP GE LX10
- Wavelength: 1310 nm / Distance: 10 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 C ~ 70 C
v1.1
Page 12 of 14
Data Sheet
V2224G-OP
SFP Module
SFP-GE-LX20
Description
SFP GE LX20
- Wavelength: 1310 nm / Distance: 20 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 C ~ 70 C
SFP-GE-LX40
SFP GE LX40
- Wavelength: 1310 nm / Distance: 40 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0C ~ 70 C
Table 6
i
3.4
SFP Modules
Other types of SFP module can be also available upon customer request.
SFP+ Options
The following different optical SFP+ modules are available and can be inserted into the
dedicated modules.
SFP+ Module
SFPP-10GE-SR
Description
SFP+ 10GE SR
-. Wavelength : 850nm / Distance : 300m / Mode : Multimode
-. Connector: LC / Data rate: 10.3125 Gbit/s / Core type: Dual Core
-. Tx Power: -5 ~ -1 dBm, Rx sensitivity: -11.1 dBm
-. Operating Temperature : 0C ~ 70 C
-. 10GBASE-SR (10G)
SFPP-10GE-LR
SFP+ 10GE LR
-. Wavelength : 1310nm / Distance : 10Km / Mode :Singlemode
-. Connector : LC / Data rate : 10.3125 Gbit/s / Core type : Dual Core
-. Tx Power: -8.2 ~ +0.5 dBm, Rx sensitivity: -12.6 dBm
-. Operating Temperature : -5C ~ 70 C
-. 10GBASE-LR (10G)
SFPP-10GE-ER
SFP+ 10GE ER
-. Wavelength : 1550nm / Distance : 40Km / Mode :Singlemode
-. Connector : LC / Data rate : 10.3125 Gbit/s / Core type : Dual Core
-. Tx Power: -4.7 ~ +4.0 dBm, Rx sensitivity: -14.1 dBm
-. Operating Temperature : 0C ~ 70 C
-. 10GBASE-ER (10G)
SFPP-10GE-ZR
SFP+ 10GE ZR
-. Wavelength : 1310nm / Distance : 70Km / Mode :Singlemode
-. Connector : LC / Data rate : 10.3125 Gbit/s / Core type : Dual Core
-. Tx Power: +3 ~ +6 dBm, Rx sensitivity: -22 dBm
-. Operating Temperature : 0C ~ 70 C
-. 10GBASE-ZR (10G)
Table 7
v1.1
SFP+ Modules
Page 13 of 14
Data Sheet
V2224G-OP
4 Ordering Information
Bases
V2224G-OP Fixed single AC power
Fixed 24-Port 100/1000Base-X, 2 modular uplink slot, 32MB Flash, and 256MB SDRAM, Fixed single AC power (SMPS), Uplink module & SFP compatible with V2724G
V2224G-OP Fixed single DC power
Fixed 24-Port 100/1000Base-X, 2 modular uplink slot, 32MB Flash, and 256MB SDRAM, Fixed single DC power (SMPS), Uplink module & SFP compatible with V2724G
SFP Options
SFP-GE-SX, SFP-GE-LX10, SFP-GE-LX20, SFP-GE-LX40
SFP+ Options
SFP+ 10GE-SR, SFP+ 10GE-LR, SFP+ 10GE-ER, SFP+ 10GE-ZR
DASAN Networks
DASAN Tower, 49, Daewangpangyo-ro644Beon-gil, Bundang-gu, Seongnam-si,
Gyeonggi-do, 463-400, KOREA Tel +82-70-7010-1000
www.dasannetworks.com
v1.1