HYDRAULIC COMPONENTS
TABLE OF CONTENTS
(1) Hydraulic Pumps Page 3
(2) Hydraulic Motors Page 29
(3) Hydraulic Flow Dividers Page 35
(4) Pump-Motor Combinations Page 47
(5) Pump-Motor-Tank Combinations Page 55
(6) Pump-Motor-Tank-Valve Combinations Page 63
(7) D.C. Pump-Motor-Tank Combinations Page 67
(8) Custom Power Units Page 79
(9) Accessories - Page 83
(10) Miscellaneous Page 129
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Page 2
HYDRAULIC PUMPS
PH Series
D Series
C Series
A Series
L Series
INDEX
Description
A Series, C Series and D Series (Data Page)
A1-A8 Pump, Bi-Directional
A21-A27 Pump Bi-Directional
C1-C8 Pump, Bi-Directional
C21-C27 Pump, Bi-Directional
C41-C49 Pump, Bi-Directional
D1-D8 Pump, Bi-Directional
D21-D27 Pump, Bi-Directional
D41-D49 Pump, Bi-Directional
Page
4
5
7
9
11
13
15
17
19
21
23
25
27
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
HYDRAULIC PUMPS
C Series
Ext. Shaft
w/Outboard Bearing
Extened Shaft
A Series
Tang Drive
4F17 Mtg.
Shown
SAE A Mtg.
Shown
SAE A Mtg.
Shown
Installation Notes
On models A1-A8, C1-C8, and D1-D8 be especially
careful since these units require that the mounting
bolts are installed to complete the assembly. The
two shipping bolts are not sufficient to make the
assembly intact and care should be exercised while
handling in that condition. Bolt torque requirements
are 13 to 17 ft-lbs.
EXTENED SHAFT
TANG DRIVE
Deltas fixed clearance gear pumps are offered in three series A, C, and D with flows ranging from 0.5 GPM to
35 GPM. Delta pumps are designed to provide greater torque efficiencies especially at high speeds.
Numerous shaft, bearing, mounting and seal options are available. Each model is designed to operate as
either a single rotation or bi-rotational pump, depending on the application.
MODEL GPM DISPLACEMENT
SLIP
AT GAL./REV IN/REV GPM
1750
PER 100
RPM
PSI
A1
0.49
0.00028
0.065
0.015
A2
0.82
0.00047
0.108
0.017
A4
1.41
0.00081
0.187
0.020
A6
2.39
0.00137
0.316
0.025
A8
3.53
0.00202
0.468
0.030
A21
3.10
0.00178
0.411
0.040
A23
5.30
0.00304
0.702
0.045
A25
7.42
0.00425
0.981
0.055
A27
11.10 0.00633
1.460
0.075
C1
0.49
0.00028
0.065
0.015
C2
0.82
0.00047
0.108
0.017
C4
1.41
0.00081
0.187
0.020
C6
2.39
0.00137
0.316
0.025
C8
3.53
0.00202
0.468
0.030
C21
3.10
0.00178
0.411
0.040
C23
5.30
0.00304
0.702
0.045
C25
7.42
0.00425
0.981
0.055
C27
11.10 0.00633
1.460
0.075
C41
11.90
0.0068
1.570
0.070
C43
17.80
0.0102
2.350
0.090
C45
23.10
0.0132
3.040
0.110
C47
29.50
0.0169
3.900
0.140
C49
33.60
0.0192
4.430
0.180
D1
0.49
0.00028
0.065
0.015
D2
0.82
0.00047
0.108
0.017
D4
1.41
0.00081
0.187
0.020
D6
2.39
0.00137
0.316
0.025
D8
3.53
0.00202
0.468
0.030
D21
3.10
0.00178
0.411
0.040
D23
5.30
0.00304
0.702
0.045
D25
7.42
0.00425
0.981
0.055
D27
11.10 0.00633
1.460
0.075
D41
11.90
0.0068
1.570
0.070
D43
17.80
0.0102
2.350
0.090
D45
23.10
0.0132
3.040
0.110
D47
29.50
0.0169
3.900
0.140
D49
33.60
0.0192
4.430
0.180
MAX. PSI
MAX. Page
INT. CONT. RPM
DUTY DUTY
2500
2500
2250
1650
1250
2000
1600
1000
750
2500
2500
2500
1850
1500
2500
2350
1500
1200
2500
2450
1850
1500
1000
2500
2500
2500
1850
1500
2500
2350
1500
1200
2500
2450
1850
1500
1000
1500
1500
1500
950
650
1500
1200
850
550
1500
1500
1500
1100
750
1500
1500
1500
1100
1500
1500
1500
1200
700
1500
1500
1500
1100
750
1500
1500
1500
1100
1500
1500
1500
1200
700
5000
5000
4000
3600
2500
5000
4000
3500
2400
5000
5000
4000
3000
1800
5000
4000
3000
1800
4000
3000
2300
1800
1800
5000
5000
4000
3000
1800
5000
4000
3000
1800
4000
3000
2300
1800
1800
5
5
5
5
5
7
7
7
7
9
9
9
9
9
11
11
11
11
13
13
13
13
13
15
15
15
15
15
17
17
17
17
19
19
19
19
19
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Pumps
MODEL
A1
A2
A4
A6
A8
SLIP GPM
PER 100 PSI
0.015
0.017
0.020
0.025
0.030
MAX.
RPM
5000
5000
4000
3600
2500
PRESS. MAX.
CONTINOUS
1500
1500
1500
1100
750
2.48
2.57
2.74
3.02
3.34
1.79
1.88
2.05
2.33
2.65
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Pumps
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Pumps
MODEL
A21
A23
A25
A27
SLIP GPM
PER 100 PSI
0.040
0.045
0.055
0.075
MAX.
RPM
5000
4000
3500
2400
PRESS. MAX.
CONTINOUS
1500
1500
1000
700
A
4.24
4.54
4.76
5.32
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Pumps
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Pumps
MODEL
C1
C2
C4
C6
C8
SLIP GPM
PER 100 PSI
0.015
0.017
0.020
0.025
0.030
SPEED
MAX. RPM
5000
5000
4000
3000
1800
2.48
2.57
2.74
3.02
3.34
0.69
0.69
0.69
0.69
0.69
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Pumps
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
MODEL
C21
C23
C25
C27
SLIP GPM
PER 100 PSI
0.040
0.045
0.055
0.075
A
3.21
3.56
3.78
4.21
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Pumps
MODEL
C41
C43
C45
C47
C49
SLIP GPM
PER 100 PSI
0.070
0.090
0.110
0.140
0.180
SPEED
MAX. RPM
4000
3000
2300
1800
1800
5.41
5.72
6.06
6.47
6.72
4.22
4.59
4.94
5.41
5.59
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Pumps
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Pumps
MODEL
D1
D2
D4
D6
D8
SLIP GPM
PER 100 PSI
0.015
0.017
0.020
0.025
0.030
A
2.82
2.91
3.08
3.36
3.68
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Pumps
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Pumps
MODEL
D21
D23
D25
D27
SLIP GPM
PER 100 PSI
0.040
0.045
0.055
0.075
A
3.21
3.56
3.78
4.21
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Pumps
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
MODEL
D41
D43
D45
D47
D49
SLIP GPM
PER 100 PSI
0.070
0.090
0.110
0.140
0.180
SPEED
MAX. RPM
4000
3000
2300
1800
1800
5.34
5.72
6.06
6.47
6.72
4.22
4.59
4.94
5.34
5.59
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
HYDRAULIC PUMPS
L6 and L8 Series
4F17 Mtg.
Shown
4F17 Mtg.
Shown
To adapt to a variety of applications, all pumps have an SAE 4F17 mounting flange plus an optional
K4 mounting bracket for foot mounting.
MODEL
Unloading Valve Settings: Factory set at 500 PSI for L6 and L8 models; 600 PSI for L24 and L26 models.
Rotation: All models rotate clockwise facing pump shaft.
Mounting: 4F17 four bolt all models.
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Page 22
HYDRAULIC PUMPS
1.25
1.00
1.50
1.38
.13
1.00
.23
.63
1.38
1.00
1.00
1.781
1.779
.31
3.56
1.00
OPTIONA L TUBE
INLET PORT
UNLOADING VALVE
FACTORY SET @500 PSI
1.66
3.14
OUTLE T PORT
INLET PORT (ON OPPOSITE SIDE)
.34 THRU
2X
(TORQUE 13 TO 17 FT-LBS)
INLET
OUTLET
MODEL
INLET
OUTLET
L6-2
.316 +.108 3000 3600 6.0\1.0
4
3/4 NPTF 1/2 NPTF 0.437 4.29 3.37
L8-4
.468 + .187 3000 3600 9.0\2.0
6
3/4 NPTF 1/2 NPTF 0.437 4.79 3.87
Note: Displacement given as larger gear set + smaller gear set.
~ GPM given as combined flow\sequenced flow.
Operation @1725 RPM will give ~ 50% of combined flow and ~ 40% of sequenced flow.
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
HYDRAULIC PUMPS
SECTION B-B
LX-X
XX
A
SECTION A-A
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
HYDRAULIC PUMPS
1.50
2.13
2.13
1.38
1.38
1.26
1.26
1.00
1.50
1.00
1.38
.30
C
.13
1.00
1.13
1.46
1.00
.63
1.78
1.00
1.25
4.18
1.38
2.00
2.13
OPTIONAL
TUBE INLET
PORT
UNLOADING VALVE
FACTORY SET @600 PSI
CHECK VALVE
2.67
OUTLET PORT
(iNLET PORT ON OPPOSITE SIDE)
5.14
3/8-16 UNC-2B
THD. (2X)
INLET
OUTLET
MODEL
INLET
OUTLET
L24-2
.880 + .222 3000 3600
16\2.5
10
1 NPTF
3/4 NPTF 0.625 5.52 4.30
L26-2
1.000 + .416 3000 3600
20\5.0
12
1.25 " TUBE 3/4 NPTF 0.625 5.82 4.59
Note: Displacement given as larger gear set + smaller gear set.
~ GPM given as combined flow\sequenced flow.
Operation @1725 RPM will give ~ 50% of combined flow and ~ 40% of sequenced flow.
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
HYDRAULIC PUMPS
SECTION B-B
A
B
LXX-X
XX
A
SECTION A-A
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Pumps
FEATURES
DESIGN LIFE/DURABILITY
PTFE bearings support the journals on a hydrodynamic film of oil. The low pressure lubrication system provides a
constant flow of oil to cool and lubricate the bearings and journals whenever rotation occurs, regardless of system
pressure. This design provides trouble free service when operated within parameters established for speed, pressure,
temperature, oil type and cleanliness.
10 inches Hg maxmum.
Must be chosen based on operating temperature. Use oil with viscosity of 45 SSU (6 cSt)
minimum and 250 SSU ( 54 cSt) maximum continuous.
14 to 176F (-10 to 80C)
Inlet, 5 ft/sec maximum; Outlet, 20 ft/sec maximum.
10 micron.
Radial or axial forces on the pump driveshaft are not normally recommended. Contact Factory for
special application considerations.
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Pumps
MODEL
PH402-A8
PH403-A9
PH404-A11
PH405-A14
PH407-A20
PH408-123
INLET
OUTLET
PORT
PORT
1 1/16-12UN 7/8-14 UN
1 1/16-12UN 7/8-14 UN
1 1/16-12UN 7/8-14 UN
1 1/16-12UN 7/8-14 UN
1 5/16-12UN 1 1/16-12UN
1 5/16-12UN 1 1/16-12UN
A
+/- .4
1.834
1.873
1.913
1.992
2.149
2.228
B
4.301
4.380
4.458
4.616
4.931
5.088
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
HYDRAULIC MOTORS
INDEX
Description
DM Series Hydraulic Motors
DM1-DM8 Hydraulic Motor, Bi-Directional
DM21-DM27 Hydraulic Motor, Bi-Directional
Page
30
31
33
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
HYDRAULIC MOTORS
4F17 Mtg.
Shown
4F17 Mtg.
Shown
DM Series hydraulic motors are designed with performance in mind, including: High-strength cast iron bodies
with precision machined filling and trapping grooves, and hardened alloy gears and shafts to run smoothly,
special Buna-N o-ring and shaft seals to withstand up to 200 PSI return line back pressure, antifriction bearings
for 60-70% starting torque, ball thrust bearings to withstand thrust and radial shaft loads, and integral check
valves to permit bi-directional rotation (to eliminate the need for external case drains). And, they will turn as
slow as 300 rpmor lower on low-torque applications.
DM Series motors are found in material handling equipment, agricultural implements, snow removal
equipment, marine gear and numerous industrial equipment and machine toolsas drives for pumps, fans,
compressors, mowers and other applications where moderate starting torque and moderate to high speed
efficiency is needed.
And, because of their design and manufacturing quality, they can be expected to add to the overall
performance and life expectancy of the equipment.
Installation Notes:
Hydraulic motor controls should be placed on the pressure side of the motor in order to preclude high seal or
case pressures. Return line should be straight to tank.
On DM1 thru DM8 series, be especially careful since these units require that the mounting bolts are installed to
complete the assembly. The two shipping bolts are not sufficient to make the assembly intact and care should
be exercised while handling in this condition. Bolt torque requirements are 13 to 17 ft-lbs.
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Motors
A
2.82
2.91
3.08
3.36
3.68
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Motors
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Motors
A
4.25
4.53
4.81
5.31
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Hydraulic Motors
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
FLOW DIVIDERS
INDEX
Description
Delta Power Rotary Flow Divider, Positive Displacement (Application Data)
P Series, Equal Flow Two Sections
P Series, Equal Flow Multi-Sections
PM Series, Equal Flow Multi-Sections
PM Series, Mixed Flow Buildable
P Series, Mixed Flow Buildable
PM Series, Equal Flow Multi-Section with Relief Valves
HPR Series, Heavy Duty with Relief Valves
Page
36
39
40
41
42
43
44
45
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
FLOW DIVIDERS
Delta Series P geared flow dividers, accurately divide flow from a single hydraulic
source into two or more equal or proportionate circuits. In like manner, the input
pressure required will be proportional to levels of flow/pressure out of the flow divider,
rather than at the highest pressure level, thereby saving what would normally be
wasted energy. Proven design, stable material selection and precision machining are
the Delta keys to reliable performance you can depend on in a variety of applications.
Application Suggestions
1. For greatest efficiency and accuracy, flow dividers should be used at near
maximum rated inlet gallonage. For quieter operations, lowered RPM should
be considered.
2. Maximum (3500) and minimum 500 RPM; inlet pressure ratings and differential
pressure ratings should be followed.
3. Provide over-pressure protection (relief valves) in each circuit.
4. When designing flow dividers into a static circuit, remember that they are
dynamic devices which do nothing while static.
5. Use SAE 10 through SAE 30 industrial petroleum-based hydraulic oil with 200
SSU viscosity; filter to 25 microns.
6. Do not use teflon tape in installation. Use plastic pipe sealant with NPTF ports.
Where two or more circuits must be
controlled independently at different
pressures: presses, machine tools,
etc.
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
FLOW DIVIDERS
Application Data
The Delta flow divider is a positive displacement flow dividing or proportioning apparatus. It will divide the flow from one
source into two or more equal or proportionate circuits, and intensify or reduce the pressure level as required. Note that
these flow dividers will operate in reverse in a combine mode, but in that mode, the accuracy likely would be significantly
reduced.
In its basic configuration, the unit consists of a number of inter coupled gear type hydraulic pump motors. Each section
must be capable of performing the pumping or motoring function. The section have a common inlet and separate outlets.
Fluid from a prime source, such as pump, supplies the motive power to the flow divider. No energy is added to the fluid in
the device, although each outlet may have an energy level difference than any other section. When the sections are of like
size, the function is to divide the total flow into equal increments of flow, and when the sections are of unlike size, the
function is to divide the flow into proportionate increments relative to the chosen geometric displacements.
Since the flow divider is a positive displacement machine, it will accomplish its function over a wide range of pressure of
viscosity differentials. Nevertheless, certain limits are imposed due to slip characteristics and torque losses in the
machine. Therefore, the performance criteria in this paper will be developed around a unit of average tolerance allowance.
The data, so derived, will be averaged. Be aware that these units can require a certain amount of break-away pressure. It
is recommended that operation at low pressures (< 100 PSI) is not attempted without consultation with the factory.
General Relationships
In any unit, neglecting any losses, there exists the relationship that
Qi = Q1+ Q2 + . Qn;
Where Qi is the flow into the unit and Q1, Q2 and Qn are the displacements out of each section. Since no energy is added
and if none were lost, it follows that
PiQi = P1Q1 + P2Q2 + . PnQn;
Where Pi is the pressure into the unit and P1, P2 and Pn are the pressure levels out of each section.
In a unit consisting of any number of/or sizes of sections
Pi =
In any actual case, the above theoretical observations must be corrected to encompass the pressure drop and slip losses
in the flow divider. The pressure drop is primarily a function of the amount of fluid and viscosity. At the usual viscosities
(100 to 300 SSU) encountered in hydraulic systems, the pressure drop Pp, can be approximated by the relationship,
where n is the number of sections,
PP
6Qi
+25
n
Since the flow divider itself is a parallel circuit, the actual pressure Pia into the unit is
Pia
+ PP
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
FLOW DIVIDERS
Slip is a function of the viscosity, pressure differential and clearance and can be estimated from the following chart:
Model
PM2
PM6
P21
P23
P25
P26
P27
P43
P47
Displacement
Gal./Rev./Sect.
.00047
.00137
.00178
.00304
.00425
.00531
.00633
.01020
.01690
Slip/100 PSI
(GPM)
.03
.04
.06
.07
.08
.10
.11
.15
.22
Max. Flow/Sect.
(GPM)
2.0
5.5
7.6
12
17
20
25
35
50
The slip function increases or decreases the flow from a section, dependent on whether the pressure differential is
positive or negative across that section.
The performance of a system would be determined in the following manner.
1. Determine the size of the sections that will best give the required flow and pressure. The displacement from each
section will be the fractional proportion of the sectional displacement versus the sum of the displacements of all
the sections. That fraction multiplied by the input flow gives output displaced by each section.
2. Determine Pp from PP
6Qi
+25
n
P1 Q1 + P2 Q2 . Pn Qn
+PP
Q1
4. Determine the pressure differential P1, P2, Pn across the individual section where P1 = Pia - P1, etc., and
from this value, determine the slips S1, S2, Sn.
5. Determine Q1a, Q2a, Qna from Q1a = Q1 + S1, etc.
The foregoing description is intended as an aid in determining the results of a flow divider system. Any specific application
should not be undertaken without independent study, evaluation and testing for suitability. Exceeding the specifications
could result in equipment malfunction, property damage, serious injury or death.
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
FLOW DIVIDERS
MODEL
PM2
PM6
P23
P27
P43
P47
SLIP
GPM/100 PSI
0.026
0.038
0.068
0.113
0.135
0.210
MAXIMUM
MAXIMUM
BOLT
A
MAX. DIFF.
INTERMITTENT CONTINUOUS TORQUE Ft.BETWEEN
PSI
PSI
Lb.
SECT. (PSI)
2500
2000
13-17
3.83
1500
2000
1500
13-17
4.72
1000
2000
1500
24-31
5.32
1000
2000
1500
24-31
6.86
1000
2000
1500
24-31
7.75
1000
2000
1500
24-31
9.25
1000
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
FLOW DIVIDERS
MODEL
PPM2
P23-60
P23-59
P23-58
P23-57
P27-60
P27-59
P27-58
P27-57
SLIP
GPM/100 PSI
0.026
0.068
0.068
0.068
0.068
0.113
0.113
0.113
0.113
MAXIMUM
MAXIMUM
BOLT
A
INTERMITTENT CONTINUOUS TORQUE Ft.PSI
PSI
Lb.
2000
1500
13-17
2000
1500
24-31
0.715
2000
1500
24-31
0.715
2000
1500
24-31
0.715
2000
1500
24-31
0.715
2000
1500
24-31
1.490
2000
1500
24-31
1.490
2000
1500
24-31
1.490
2000
1500
24-31
1.490
2.39
2.39
2.39
2.39
3.16
3.16
3.16
3.16
2.56
2.56
2.56
2.56
3.33
3.33
3.33
3.33
8.83
11.39
13.95
16.51
11.16
14.49
17.82
21.15
MAX. DIFF.
BETWEEN
SECT. (PSI)
1000
1000
1000
1000
1000
1000
1000
1000
1000
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
FLOW DIVIDERS
PM6
MODEL
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
FLOW DIVIDERS
MODEL
PM1
PM2
PM4
PM6
PM8
SLIP
GPM/100 PSI
0.015
0.017
0.020
0.025
0.030
MAXIMUM
MAXIMUM
BOLT
MAX. DIFF. MAXIMUM MINIMUM
A
INTERMITTENT CONTINUOUS TORQUE BETWEEN
RPM
RPM
PSI
PSI
Ft.-Lb. SECT. (PSI)
2500
2000
24-31
1000
3500
500
0.14
2500
2000
24-31
1000
3500
500
0.23
2000
1500
24-31
1000
3500
500
0.31
2000
1500
24-31
1000
3500
500
0.40
2000
1500
24-31
1000
3500
500
0.53
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
FLOW DIVIDERS
MODEL
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
FLOW DIVIDERS
PPM2RV
MODEL
NUMBER OF
TOTAL
SECTIONS MAX. INLET
(GPM)
PM2RV
2
3.5
PM6RV
2
9.5
PPM2RV
4
7.0
0 PSI DISP.
PER SECT.
GAL./REV,
0.00047
0.00137
0.00047
SLIP
MAXIMUM
MAXIMUM
BOLT
GPM/100 INTERMITTENT CONTINUOU TORQUE
PSI
PSI
S PSI
Ft.-Lb.
0.026
2500
2000
13-17
0.038
2000
1500
13-17
0.026
2000
1500
13-17
MAX. DIFF.
BETWEEN
SECT. (PSI)
1500
1000
1000
MAXIMUM MINIMUM
RPM
RPM
3500
3500
3500
500
500
500
0.23
0.40
0.53
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
FLOW DIVIDERS
RELIEF VALVE
RELIEF VALVE
HYDRAULIC SCHEMATIC
(TWO SECTION SHOWN)
E-mail: delta@delta-power.com
FLOW DIVIDERS
EQUAL FLOW
TWO SECTION
0 PSI DISPLACEMENT
DIMENSION
(2) SECTION PER SECTION GAL./REV,
A
B
MODEL
HPR23
0.00304
3.19 [81.0]
2.56 [65.0]
HPR27
0.06330
3.96 [100.6]
3.34 [84.8]
Note: Dimensions in [XX.X] are mm
MAX. INLET
@3500 RPM
GPM [LPM]
21 GPM [79 LPM]
44 GPM [166 LPM]
EQUAL FLOW
MULTI-SECTION
(MIXED FLOW BUILDABLE ARE ALSO AVAILABLE)
0 PSI DISPLACEMENT
MAX. INLET
DIMENSION
(4) SECTION PER SECTION GAL./REV,
@3500 RPM
A
B
MODEL
GPM [LPM]
HPR21-59
0.00178
2.89 [73.4]
2.26 [57.4]
25 GPM [95 LPM]
HPR23-59
0.00304
3.19 [81.0]
2.56 [65.0]
42 GPM [160 LPM]
HPR25-59
0.00425
3.47 [88.1]
2.85 [72.4]
59 GPM 223 LPM]
HPR26-59
0.00531
3.72 [94.5]
3.10 [78.7]
74 GPM [280 LPM]
HPR27-59
0.00633
3.96 [100.6]
3.34 [84.8]
88 GPM [333 LPM]
Note: Dimensions in [XX.X] are mm
FOR QUIETER OPERATION LIMIT SPEED TO 2000 RPM
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
A Series
CW Series
C Series
INDEX
A Series Units
Description
Page
49
C Series Units
51
CW Series Units
53
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Page 48
A Series Units
A1 thru A8 Pump/Motor
A Series pump/motor combinations are high quality pre-engineered packages designed to satisfy medium service,
steady load and/or intermittent duty applications: hi-flow, low pressure, lube transfer, recirculation, scavenge and filtration.
As shown below, a variety of performance characteristics are available through the combination of several pump
configurations with single and/or three phase TEFC heavy-duty ball bearing motors. All combinations are bi-directional.
The pumps, also available separately, feature high strength cast iron bodies with precision machined internal trapping
grooves, hardened alloy gears and shafts, leaded bronze sleeve bearings and Buna-N seals and o-rings to provide long,
quiet, trouble-free performance.
Pump / Motor Specifications
Data shown is for continuous duty. For intermittent peaking duty, 30 seconds at peak load, pressure as high as 150% is
attainable, limited to 3000 PSI maximum.
Pump
Motor
A154
HP .1725 RPM
1 PHASE TEFC
A354
HP .1725 RPM
3 PHASE TEFC
A174
HP .1725 RPM
1 PHASE TEFC
A374
HP .1725 RPM
3 PHASE TEFC
A1104
1 HP .1725 RPM
1 PHASE TEFC
A3104
1 HP .1725 RPM
3 PHASE TEFC
A1154
1 HP .1725 RPM
1 PHASE TEFC
A3154
1 HP .1725 RPM
3 PHASE TEFC
A1
.00028 GPR
.31 GPM
1500 PSI
A1+A154
.31 GPM
1500 PSI
A1+A354
.25 GPM
2250 PSI
A1+A174
.25 GPM
2250 PSI
A1+A374
.25 GPM
2250 PSI
A1+A1104
.25 GPM
2250 PSI
A1+A3104
A2
.00047 GPR
.70 GPM
900 PSI
A2+A154
.70 GPM
900 PSI
A2+A354
.65 GPM
1350 PSI
A2+A174
.65 GPM
1350 PSI
A2+A374
.58 GPM
1800 PSI
A2+A1104
.58 GPM
1800 PSI
A2+A3104
A4
.00081 GPR
1.33 GPM
525 PSI
A4+A154
1.33 GPM
525 PSI
A4+A354
1.28 GPM
775 PSI
A4+A174
1.28 GPM
775 PSI
A4+A374
1.25 GPM
1050 PSI
A4+A1104
1.25 GPM
1050 PSI
A4+A3104
1.17 GPM
1550 PSI
A4+A1154
1.17 GPM
1550 PSI
A4+A3154
A6
.00137 GPR
2.32 GPM
300 PSI
A6+A154
2.32 GPM
300 PSI
A6+A354
2.28 GPM
450 PSI
A6+A174
2.28 GPM
450 PSI
A6+A374
2.25 GPM
625 PSI
A6+A1104
2.25 GPM
625 PSI
A6+A3104
2.18 GPM
925 PSI
A6+A1154
2.18 GPM
925 PSI
A6+A3154
A8
.00202 GPR
3.46 GPM
200 PSI
A8+A154
3.46 GPM
200 PSI
A8+A354
3.44 GPM
300 PSI
A8+A174
3.44 GPM
300 PSI
A8+A374
3.40 GPM
425 PSI
A8+A1104
3.40 GPM
425 PSI
A8+A3104
3.34 GPM
625 PSI
A8+A1154
3.34 GPM
625 PSI
A8+A3154
A21
.00178 GPR
3.0 GPM
225 PSI
A21+A154
3.0 GPM
225 PSI
A21+A354
3.0 GPM
350 PSI
A21+A174
3.0 GPM
350 PSI
A21+A374
2.9 GPM
475 PSI
A21+A1104
2.9 GPM
475 PSI
A21+A3104
2.8 GPM
70 PSI
A21+A1154
2.8 GPM
700 PSI
A21+A3154
A23
.00304 GPR
5.3 GPM
150 PSI
A23+A154
5.3 GPM
150 PSI
A23+A354
5.2 GPM
200 PSI
A23+A174
5.2 GPM
200 PSI
A23+A374
5.2 GPM
275 PSI
A23+A1104
5.2 GPM
275 PSI
A23+A3104
5.1 GPM
425 PSI
A23+A1154
5.1 GPM
425 PSI
A23+A3154
A25
.00425 GPR
7.4 GPM
100 PSI
A25+A154
7.4 GPM
100 PSI
A25+A354
7.3 GPM
150 PSI
A25+A174
7.3 GPM
150 PSI
A25+A374
7.3 GPM
200 PSI
A25+A1104
7.3 GPM
200 PSI
A25+A3104
7.2 GPM
300 PSI
A25+A1154
7.2 GPM
300 PSI
A25+A3154
A27
.00633 GPR
10.9 GPM
75 PSI
A27+A154
10.9
75 PSI
A27+A354
11.0 GPM
100 PSI
A27+A174
11.0 GPM
100 PSI
A27+A374
11.0 GPM
125 PSI
A27+A1104
11.0 GPM
125 PSI
A27+A3104
10.9 GPM
200 PSI
A27+A1154
10.9 GPM
200 PSI
A27+A3154
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
A1 thru A8 Pump/Motor
Performance Data
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
C Series Units
C1 thru C8 Pump/Motor Combinations
All C Series pump/motor units are bi-directional. The precision alignment of the motor to C Series is assured by a
machined adaptor bracket. The to 1 H.P. electric motors are frame 56, continuous duty, ball-bearing, totally
enclosed, fan cooled units of the highest quality. The motors are offered as standard in either single phase 115, 230 volt,
1750 RPM, or 208 , 230, 460 volt, 1750 RPM, 50/60 cycle.
Pump / Motor Specifications
Data shown is for continuous duty. For intermittent peaking duty 30 seconds at peak load, pressure as high as 150% is
attainable, limited to 3000 PSI maximum.
Pump
C1
C2
C4
C6
C8
.00028 GPR
.00047 GPR
.00081 GPR
.00137 GPR
.00202 GPR
Motor
C154
.31 GPM
.70 GPM
1.33 GPM
2.32 GPM
3.46 GPM
HP .1725 RPM
1500 PSI
900 PSI
525 PSI
300 PSI
200 PSI
1 PHASE TEFC
C1+C154
C2+C154
C4+C154
C6+C154
C8+C154
C354
.31 GPM
.70 GPM
1.33 GPM
2.32 GPM
3.46 GPM
HP .1725 RPM
1500 PSI
900 PSI
525 PSI
300 PSI
200 PSI
3 PHASE TEFC
C1+C354
C2+C354
C4+C354
C6+C354
C8+C354
C174
.25 GPM
.65 GPM
1.28 GPM
2.28 GPM
3.44 GPM
HP .1725 RPM
2250 PSI
1350 PSI
775 PSI
450 PSI
300 PSI
1 PHASE TEFC
C1+C174
C2+C174
C4+C174
C6+C174
C8+C174
C374
.25 GPM
.65 GPM
1.28 GPM
2.28 GPM
3.44 GPM
HP .1725 RPM
2250 PSI
1350 PSI
775 PSI
450 PSI
300 PSI
3 PHASE TEFC
C1+C374
C2+C374
C4+C374
C6+C374
C8+C374
C1104
.25 GPM
.58 GPM
1.25 GPM
2.25 GPM
3.40 GPM
1 HP .1725 RPM
2250 PSI
1800 PSI
1050 PSI
625 PSI
425 PSI
1 PHASE TEFC
C1+C1104
C2+C1104
C4+C1104
C6+C1104
C8+C1104
C3104
.25 GPM
.58 GPM
1.25 GPM
2.25 GPM
3.40 GPM
1 HP .1725 RPM
2250 PSI
1800 PSI
1050 PSI
625 PSI
425 PSI
3 PHASE TEFC
C1+C3104
C2+C3104
C4+C3104
C6+C3104
C8+C3104
C1154
1.17 GPM
2.18 GPM
3.34 GPM
1 HP .1725 RPM
1550 PSI
925 PSI
625 PSI
1 PHASE TEFC
C4+C1154
C6+C1154
C8+C1154
C3154
1.17 GPM
2.18 GPM
3.34 GPM
1 HP .1725 RPM
1550 PSI
925 PSI
625 PSI
3 PHASE TEFC
C4+C3154
C6+C3154
C8+C3154
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Pump Part
C1
C2
C4
C6
C8
Dim. "D"
2.48
2.57
2.74
3.02
3.34
Motor Part
C154
C354
C174
C374
C1104
C3104
C1154
C3154
Dim. "A"
9.62
9.25
10.62
10.50
11.25
10.00
12.25
10.25
Note: Motor and Bracket dimensions subject to change due to availability of inventory.
Performance Data
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
CW Series Units
CW21 thru CW27 Pump/Motor Combination
All CW Series pump/motor units are bi-directional. The precision alignment of the motor to CW Series is assured by a
machined adaptor bracket. The 3 to 20 H.P. electric motors are frame 182TC to 256TC, continuous duty, ball-bearing,
totally enclosed, fan cooled units of the highest quality. The motors are offered as standard in either three phase 115, 230
volt, 1750 RPM, or 208, 230, 460 volt, 1750 RPM, 50/60 cycle.
Pump / Motor Specifications
Data shown is for continuous duty. For intermittent peaking duty, 30 seconds at peak load, pressure as high as 150% is
attainable, limited to 3000 PSI maximum.
Motor
(All 1750 RPM,
3 Phase, TEFC)
3304
3 HP
182TC Frame
3504
5 HP
184TC Frame
3754
7 HP
213TC Frame
31004
10 HP
215TC Frame
31504
15 HP
254TC Frame
32004
20 HP
256TC Frame
CW21
.00178 GPR
CW21-3304
2.4 GPM
1400 PSI
CW21-3504
2.1 GPM
2350 PSI
CW23
.00304 GPR
CW23-3304
4.8 GPM
825 PSI
CW23-3504
4.5 GPM
1375 PSI
CW23-3754
4.1 GPM
2050 PSI
CW25
.00425 GPR
CW25-3304
7.1 GPM
600 PSI
CW25-3504
6.6 GPM
1000 PSI
CW25-3754
6.2 GPM
1475 PSI
CW25-31004
6.0 GPM
1875 PSI
CW27
.00633 GPR
CW27-3304
10.8 GPM
400 PSI
CW27-3504
10.3 GPM
650 PSI
CW27-3754
10.2 GPM
1000 PSI
CW27-31004
9.9 GPM
1325 PSI
Pump
CW41
.0068 GPR
CW41-3304
11.4 GPM
375 PSI
CW41-3504
11.2 GPM
625 PSI
CW41-3754
11.0 GPM
925 PSI
CW41-31004
10.9 GPM
1225 PSI
CW41-31504
9.7 GPM
1850 PSI
CW43
.0102 GPR
CW43-3304
17.2 GPM
250 PSI
CW43-3504
17.0 GPM
400 PSI
CW43-3754
16.9 GPM
625 PSI
CW43-31004
16.8 GPM
825 PSI
CW43-31504
16.5 GPM
1225 PSI
CW43-32004
16.25 GPM
1650 PSI
CW45
.0132 GPR
CW45-3304
22.5 GPM
200 PSI
CW45-3504
22.2 GPM
325 PSI
CW45-3754
22.0 GPM
475 PSI
CW45-31004
21.8 GPM
625 PSI
CW45-31504
21.0 GPM
950 PSI
CW45-32004
19.8 GPM
1275 PSI
CW47
.0169 GPR
CW47-3304
28.8 GPM
150 PSI
CW47-3504
28.4 GPM
250 PSI
CW47-3754
28.2 GPM
375 PSI
CW47-31004
28.0 GPM
500 PSI
CW47-31504
27.9 GPM
750 PSI
CW47-32004
27.8 GPM
1000 PSI
CW49
.0192 GPR
CW49-3304
32.8 GPM
125 PSI
CW49-3504
32.5 GPM
225 PSI
CW49-3754
32.3 GPM
325 PSI
CW49-31004
32.0 GPM
425 PSI
CW49-31504
31.8 GPM
650 PSI
CW49-32004
31.6 GPM
875 PSI
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
MOTOR
MODEL
3304
3504
3754
31004
31504
32004
A
13.13
14.13
15.81
17.31
18.91
20.66
B
C
9.47
9.47
10.86
10.86
12.56 1.56
12.56 1.56
D
7.19
7.19
8.66
8.66
9.44
9.44
E
4.73
4.73
5.43
5.43
6.28
6.28
F
5.69
5.69
6.66
6.66
7.44
7.44
Dimensions
G
H
3.75 9.23
3.75 9.23
4.25 10.69
4.25 10.69
5.00 12.56
5.00 12.56
I
7.25
7.75
8.56
9.31
9.78
10.66
J
K
2.25 5.50
2.75 6.50
2.75 6.50
3.25 8.00
4.13 9.50
5.00 11.25
L
3.38
3.38
4.00
4.00
4.50
4.50
M
3.87
3.87
4.34
4.34
5.09
5.09
Note: Motor and Bracket dimensions subject to change due to availability of inventory.
Pump
Model
CW21
CW23
CW25
CW27
CW41
CW43
CW45
CW47
CW49
M
0.63
0.63
0.63
0.63
0.91
0.91
0.91
0.91
0.91
N
3.2
3.5
3.78
4.27
5.41
5.72
6.06
6.47
6.72
Dimensions
P
R
1.75
1.75
1.75
1.75
4.22 5.38
4.59 5.38
4.94 5.38
5.41 5.38
5.59 5.38
S
3/4 NPTF (2)
3/4 NPTF (2)
3/4 NPTF (2)
3/4 NPTF (2)
1 1/4 NPTF (2)
1 1/4 NPTF (2)
1 1/4 NPTF (2)
1 1/4 NPTF (2)
1 1/4 NPTF (2)
Performance Data
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
B Series
CT Series
BCV Series
INDEX
Description
Page
57
B Series Units
CT and CX Series Units
59
61
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Page 56
Caution: Relief valves must be set prior to installation. They are not factory
preset. Relief valves will include springs which will allow relief valves settings to
the pressures indicated on the chart.
With the 1, 1 or 2 gallon tank and TEFC 56 frame motors, B models are one of the most compact, utilized power
packages available today. The 1 and 1 gallon tank unit includes a custom heat dissipating aluminum tank and an
externally adjustable relief valve. Units can be mounted horizontally (foot down) or vertically (tank down). TEFC motors
are 56 frame specially configured for Delta Power B units, 4 pole motors run at the highly desirable speed of 1725 RPM
rather than the 3450 version normally used on competitors units.
While each unit is a complete power unit, their scope is radically increased by adapting to valve accessories like
85005677 found in section 9 of this catalog. Please refer to Section 9 for other adaptations.
Pump / Motor Specifications
Data shown is for continuous duty. For intermittent peaking duty, 30 seconds at peak load, pressure as high as 150% is
attainable, limited to 3000 PSI maximum.
Note: 3 phase motors can run on 50/60 cycles but flow at 50 cycles will be reduced to 5/6 of noted flow since the motor
will run at 5/6 of the RPM.
Pump
Motor
B154
1/2 H.P. 1725 RPM
1 Phase TEFC
B354
1/2 H.P. 1725 RPM
3 Phase TEFC
B174
3/4 H.P. 1725 RPM
1 Phase TEFC
B374
3/4 H.P. 1725 RPM
3 Phase TEFC
B1104
1 H.P. 1725 RPM
1 Phase TEFC
B3104
1 H.P. 1725 RPM
3 Phase TEFC
B1154
1-1/2 H.P. 1725 RPM
1 Phase TEFC
B3154
1-1/2 H.P. 1725 RPM
3 Phase TEFC
B3204
2 H.P. 1725 RPM
3 Phase TEFC
B3304
3 H.P. 1725 RPM
3 Phase TEFC
Intermittent Duty
B1
B2
.00028 GPR .00047 GPR
.31 GPM
.70 GPM
1500 PSI
900 PSI
B1+B154
B2+B154
.31 GPM
.70 GPM
1500 PSI
900 PSI
B1+B354
B2+B354
.25 GPM
.65 GPM
2250 PSI
1350 PSI
B1+B174
B2+B174
.25 GPM
.65 GPM
2250 PSI
1350 PSI
B1+B374
B2+B374
.25 GPM
.58 GPM
2250 PSI
1800 PSI
B1+B1104
B2+B1104
.25 GPM
.58 GPM
2250 PSI
1800 PSI
B1+B3104
B2+B3104
B4
B6
B8
.0081 GPR .00137 GPR .00202 GPR
1.33 GPM 2.32 GPM
3.46 GPM
525 PSI
300 PSI
200 PSI
B4+B154
B6+B154
B8+B154
1.33 GPM 2.32 GPM
3.46 GPM
525 PSI
300 PSI
200 PSI
B4+B354
B6+B354
B8+B354
1.28 GPM 2.28 GPM
3.44 GPM
775 PSI
450 PSI
300 PSI
B4+B174
B6+B174
B8+B174
1.28 GPM 2.28 GPM
3.44 GPM
775 PSI
450 PSI
300 PSI
B4+B374
B6+B374
B8+B374
1.25 GPM 2.25 GPM
3.40 GPM
1050 PSI
625 PSI
425 PSI
B4+B1104 B6+B1104
B8+B1104
1.25 GPM 2.25 GPM
3.40 GPM
1050 PSI
625 PSI
425 PSI
B4+B3104 B6+B3104
B8+B3104
1.17 GPM 2.18 GPM
3.34 GPM
1550 PSI
925 PSI
625 PSI
B4+B1154 B6+B1154
B8+B1154
1.17 GPM 2.18 GPM
3.34 GPM
1550 PSI
925 PSI
625 PSI
B4+B3154 B6+B3154
B8+B3154
2.06 GPM
3.26 GPM
1225 PSI
850 PSI
B6+B3204
B8+B3204
1.90 GPM
3.12 GPM
1850 PSI
1250 PSI
B6+B3304
B8+B3304
B6+B174
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
E
9.88
9.25
10.75
9.25
10.88
9.88
11.76
9.75
10.88
11.75
Performance Data
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Pump motor combinations are offered with 5 or 10 gallon tanks to form complete hydraulic power packages. When
ordering, specify pump, motor, and tank sizes. Adding a T to the model numbers of pump and motor in the chart
designates a 5 gallon tank. Using an X in the number instead of the T, designates a 10 gallon tank. For example, CT6
+ C354 would specify a complete unit: pump C6, motor size C354, 5 gallon tank T. To order a 10 gallon tank
combination, the number would be CX6 + C354.
All tanks include the following: suction strainer (100 mesh); breather (40 micron); oil sight level glass; motor mounting
holes drilled and tapped. Pump-motor-tank combinations include piping to the suction side of the pump.
The precision alignment of the motor to the C Series pump is assured by a machined adaptor bracket. The to 1
H.P. electric motors are frame 56C, continuous duty, ball-bearing, totally enclosed, fan cooled units of the highest quality.
The motors are offered as standard in either single phase, 115 and 230 volt, 1750 RPM or three phase, 208, 230 and 460
volt, 1750 RPM, 50/60 cycle current.
Pump / Motor Specifications
Data shown is for continuous duty. For intermittent peaking duty, 30 seconds at peak load, pressure as high as 150% is
attainable, limited to 3000 PSI maximum.
Note: 3 phase motors can run on 50/60 cycles but flow at 50 cycles will be reduced to 5/6 of noted flow since the motor
will run at 5/6 of the RPM.
Pump
Motor
C154
1/2 H.P. 1725 RPM
1 Phase TEFC
C354
1/2 H.P. 1725 RPM
3 Phase TEFC
C174
3/4 H.P. 1725 RPM
1 Phase TEFC
C374
3/4 H.P. 1725 RPM
3 Phase TEFC
C1104
1 H.P. 1725 RPM
1 Phase TEFC
C3104
1 H.P. 1725 RPM
3 Phase TEFC
C1154
1-1/2 H.P. 1725 RPM
1 Phase TEFC
C3154
1-1/2 H.P. 1725 RPM
3 Phase TEFC
C1
C2
.00028 GPR .00047 GPR
.31 GPM
.70 GPM
1500 PSI
900 PSI
C1+C154
C2+C154
.31 GPM
.70 GPM
1500 PSI
900 PSI
C1+C354
C2+C354
.25 GPM
.65 GPM
2250 PSI
1350 PSI
C1+C174
C2+C174
.25 GPM
.65 GPM
2250 PSI
1350 PSI
C1+C374
C2+C374
.25 GPM
.58 GPM
2250 PSI
1800 PSI
C1+C1104 C2+C1104
.25 GPM
.58 GPM
2250 PSI
1800 PSI
C1+C3104 C2+C3104
C4
C6
C8
.0081 GPR .00137 GPR .00202 GPR
1.33 GPM 2.32 GPM
3.46 GPM
525 PSI
300 PSI
200 PSI
C4+C154
C6+C154
C8+C154
1.33 GPM 2.32 GPM
3.46 GPM
525 PSI
300 PSI
200 PSI
C4+C354
C6+C354
C8+C354
1.28 GPM 2.28 GPM
3.44 GPM
775 PSI
450 PSI
300 PSI
C4+C174
C6+C174
C8+C174
1.28 GPM 2.28 GPM
3.44 GPM
775 PSI
450 PSI
300 PSI
C4+C374
C6+C374
C8+C374
1.25 GPM 2.25 GPM
3.40 GPM
1050 PSI
625 PSI
425 PSI
C4+C1104 C6+C1104 C8+C1104
1.25 GPM 2.25 GPM
3.40 GPM
1050 PSI
625 PSI
425 PSI
C4+C3104 C6+C3104 C8+C3104
1.17 GPM 2.18 GPM
3.34 GPM
1550 PSI
925 PSI
625 PSI
C4+C1154 C6+C1154 C8+C1154
1.17 GPM 2.18 GPM
3.34 GPM
1550 PSI
925 PSI
625 PSI
C4+C3154 C6+C3154 C8+C3154
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
MOTOR
DIMENSION
C154
13.38
C354
12.75
C174
14.25
C374
12.75
C1104
14.43
C3104
13.43
C31154
15.25
C3154
13.38
PUMP
C1
C2
C4
C6
C8
DIMENSION
2.48
2.57
2.74
3.02
3.34
Note: Motor and bracket dimensions subject to change due to availability of inventory.
Performance Data
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Vertical Pump Motor, combinations 3.5 to 10.5GPM with 3 to 20 HP, C face, TEFC motors (Pressures to 3000 PSI).
Available on 15, 20 and 30 gallon non JIC reservoirs. Each unit features a fixed displacement gear pump submerged
below oil level for assured pump filling and quiet operation. Filler breather assembly, suction strainer, sight level and
temperature gauge standard. Optional valve systems result in a complete custom hydraulic Power Unit. These units use
the PH series pumps noted in the pump section of the catalog.
Accessories/Options
Relief valve
Pressure gauge and shutoff
Return line filter
Directional control valves
Single-phase motors
Explosion-proof motors
Custom manifolds
Pressure switch
BCV312
.499 CIR
BCV313
.589 CIR
BCV314
.677 CIR
BCV315
.860 CIR
BCV318
1.220 CIR
BCV319
1.403 CIR
1225 PSI
1000 PSI
3.7 GPM
4.4 GPM
BCV312-3304 BCV313-3304
900 PSI
5.0 GPM
BCV314-3304
700 PSI
6.4 GPM
BCV315-3304
500 PSI
9.1 GPM
BCV318-3304
425 PSI
10.4 GPM
BCV319-3304
2050 PSI
1725 PSI
3.7 GPM
4.4 GPM
BCV312-3504 BCV313-3504
1500 PSI
5.0 GPM
BCV314-3504
1200 PSI
6.4 GPM
BCV315-3504
825 PSI
9.1 GPM
BCV318-3504
725 PSI
10.4 GPM
BCV319-3504
3000 PSI
2600 PSI
3.6 GPM
4.3 GPM
BCV312-3754 BCV313-3754
2250 PSI
4.9 GPM
BCV314-3754
1725 PSI
6.4 GPM
BCV315-3754
1250 PSI
9.1 GPM
BCV318-3754
1100 PSI
10.3 GPM
BCV319-3754
3000 PSI
3000 PSI
2325 PSI
1675 PSI
1450 PSI
4.3 GPM
4.9 GPM
6.3 GPM
9.0 GPM
10.3 GPM
BCV313-31004 BCV314-31004 BCV315-31004 BCV318-31004 BCV319-31004
3000 PSI
2500 PSI
2200 PSI
6.3 GPM
9.0 GPM
10.2 GPM
BCV315-31504 BCV318-31504 BCV319-31504
2850 PSI
2500 PSI
9.0 GPM
10.2 GPM
BCV318-32004 BCV319-32004
Note: 3 phase motors can run on 50/60 cycles but flow at 50 cycles will be reduced to 5/6 of noted flow since the motor
will run at 5/6 of the RPM.
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
TANK
T-15V
T-20V
T-30V
MOTOR
"A"
"B"
"B"
"B"
12.96
25.52
29.52
37.52
3304
13.96
26.52
30.52
38.52
3504
13.99
26.92
29.92
38.92
3754
16.49
29.05
33.05
41.05
31004
31504
17.87
30.43
34.43
42.43
32004
19.63
32.19
36.19
44.19
12.56
16.56
24.56
"C"
Note: Motor and Flange dimensions are
approximate dependent on current availability
Performance Data
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
BV Series
INDEX
Description
BV Series Units
Page
65
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Page 64
Caution: Relief valves must be set prior to installation. They are not factory
preset. Relief valves will include springs which will allow relief valves settings to
the pressures indicated on the chart.
Delta BV models provide increased flexibility by incorporating a standard 4way 3position valve directly to the power unit.
In all, over 100 standard model and combinations to choose from.
Satisfy many custom circuit requirements through use of standard Delta valves, manifolds and stack modules illustrated.
Pump / Motor Specifications
Data shown is for continuous duty. For intermittent peaking duty, 30 seconds at peak load, pressure as high as 150% is
attainable, limited to 3000 PSI maximum.
Note: 3 phase motors can run on 50/60 cycles but flow at 50 cycles will be reduced to 5/6 of noted flow since the motor
will run at 5/6 of the RPM.
Pump
BV1
BV2
BV4
.00028 GPR .00047 GPR .0081 GPR
B154
.31 GPM
.70 GPM
1.33 GPM
1/2 H.P. 1725 RPM
1500 PSI
900 PSI
525 PSI
1 Phase TEFC
BV1+B154 BV2+B154 BV4+B154
B354
.31 GPM
.70 GPM
1.33 GPM
1/2 H.P. 1725 RPM
1500 PSI
900 PSI
525 PSI
3 Phase TEFC
BV1+B354 BV2+B354 BV4+B354
B174
.25 GPM
.65 GPM
1.28 GPM
3/4 H.P. 1725 RPM
2250 PSI
1350 PSI
775 PSI
1 Phase TEFC
BV1+B174 BV2+B174 BV4+B174
B374
.25 GPM
.65 GPM
1.28 GPM
3/4 H.P. 1725 RPM
2250 PSI
1350 PSI
775 PSI
3 Phase TEFC
BV1+A374 BV2+B374 BV4+B374
B1104
.25 GPM
.58 GPM
1.25 GPM
1 H.P. 1725 RPM
2250 PSI
1800 PSI
1050 PSI
1 Phase TEFC
BV1+B1104 BV2+B1104 BV4+B1104
B3104
.25 GPM
.58 GPM
1.25 GPM
1 H.P. 1725 RPM
2250 PSI
1800 PSI
1050 PSI
3 Phase TEFC
BV1+B3104 BV2+B3104 BV4+B3104
B1154
1.17 GPM
1-1/2 H.P. 1725 RPM
1550 PSI
1 Phase TEFC
BV4+B1154
B3154
1.17 GPM
1-1/2 H.P. 1725 RPM
1550 PSI
3 Phase TEFC
BV4+B3154
B3204
2 H.P. 1725 RPM
3 Phase TEFC
B3304
3 H.P. 1725 RPM
3 Phase TEFC
Intermittent Duty
Motor
BV6
.00137 GPR
2.32 GPM
300 PSI
BV6+B154
2.32 GPM
300 PSI
BV6+B354
2.28 GPM
450 PSI
BV6+B174
2.28 GPM
450 PSI
BV6+B374
2.25 GPM
625 PSI
BV6+B1104
2.25 GPM
625 PSI
BV6+B3104
2.18 GPM
925 PSI
BV6+B1154
2.18 GPM
925 PSI
BV6+B3154
2.06 GPM
1225 PSI
BV6+B3204
1.90 GPM
1850 PSI
BV6+B3304
BV8
.00202 GPR
3.46 GPM
200 PSI
BV8+B154
3.46 GPM
200 PSI
BV8+B354
3.44 GPM
300 PSI
BV8+B174
3.44 GPM
300 PSI
BV8+B374
3.40 GPM
425 PSI
BV8+B1104
3.40 GPM
425 PSI
BV8+B3104
3.34 GPM
625 PSI
BV8+B1154
3.34 GPM
625 PSI
BV8+B3154
3.26 GPM
850 PSI
BV8+B3204
3.12 GPM
1250 PSI
BV8+B3304
BV6+B174
Pump No.
B1
B2
B4
B6
B8
GPM @ 0.PSI
1725 RPM
0.48
0.81
1.40
2.36
3.49
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
A
11.13
10.50
10.50
10.50
12.13
11.00
12.50
11.00
12.13
12.88
B
19.69
19.06
19.06
19.06
20.69
19.56
21.06
19.56
20.69
21.44
C
19.38
18.75
18.75
18.75
20.38
19.25
20.75
19.25
20.38
21.13
D
9.75
9.13
9.13
9.13
10.75
9.63
11.13
9.63
10.75
11.50
Accessory Options
SYMBOL
DESCRIPTION
Part Number
110 VAC
220 VAC
22020116
22020117
22020118
22020119
22020120
22020121
22020122
22020123
E
9.88
9.25
9.25
9.25
10.88
9.75
11.25
9.75
10.88
11.63
21001003
21001007
21002001
21004001
Stack Modules
SYMBOL
Performance Data
DESCRIPTION
Flow Control
Meter In/Out
Dual Pilot Operated
Check (4:1 Ratio)
Part No.
3000 PSI
85004206
3000 PSI
85004025
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
DC POWER UNITS
HP200 Series
HP203 Series
HP205 Series
HP204 Series
HP208 Series
INDEX
Description
HP200 Series - Pump/Motor
Page
69
71
73
75
77
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Page 68
DC POWER UNITS
12 VDC Voltage
3.5
300
200
1.5
Amps
2.5
2.0
100
1.0
300
3.0
Flow GPM
3.0
0.5
2.5
200
2.0
Amps
3.5
Flow GPM
400
4.0
400
4.0
1.5
100
1.0
0.5
0.0
0
500
1000
1500
2000
2500
0
3000
0.0
0
500
1000
Pressure PSI
Flow GPM
1500
2000
2500
0
3000
Pressure PSI
Flow GPM
Amps
Amps
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
DC POWER UNITS
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
DC POWER UNITS
24 VDC Voltage
12 VDC Voltage
4.0
3.5
3.0
300
1.0
Flow GPM
200
1.5
Amps
2.5
2.0
300
3.0
100
0.5
2.5
200
2.0
Amps
3.5
Flow GPM
400
4.0
400
1.5
100
1.0
0.5
0.0
0
500
1000
1500
2000
2500
0
3000
0.0
0
500
1000
Pressure PSI
Flow GPM
1500
2000
2500
0
3000
Pressure PSI
Flow GPM
Amps
Amps
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
DC POWER UNITS
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
DC POWER UNITS
24 VDC Voltage
12 VDC Voltage
4.0
3.5
300
1.5
1.0
Flow GPM
200
Amps
2.0
300
3.0
2.5
100
0.5
2.5
200
2.0
Amps
3.0
Flow GPM
400
4.0
400
3.5
1.5
100
1.0
0.5
0.0
0
500
1000
1500
2000
2500
0
3000
0.0
0
500
1000
Pressure PSI
Flow GPM
1500
2000
2500
0
3000
Pressure PSI
Flow GPM
Amps
Amps
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
DC POWER UNITS
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
DC POWER UNITS
24 VDC Voltage
12 VDC Voltage
3.5
300
200
1.5
Amps
2.5
2.0
100
1.0
300
3.0
Flow GPM
3.0
0.5
2.5
200
2.0
Amps
3.5
Flow GPM
400
4.0
400
4.0
1.5
100
1.0
0.5
0.0
0
500
1000
1500
2000
2500
0
3000
0.0
0
500
1000
Pressure PSI
Flow GPM
1500
2000
2500
0
3000
Pressure PSI
Flow GPM
Amps
Amps
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
DC POWER UNITS
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
DC POWER UNIT
12 VDC Voltage
3.5
300
1.5
Amps
200
2.0
100
1.0
300
3.0
2.5
Flow GPM
3.0
0.5
2.5
200
2.0
Amps
3.5
Flow GPM
400
4.0
400
4.0
1.5
100
1.0
0.5
0.0
0
500
1000
1500
2000
2500
0
3000
0.0
0
500
1000
Pressure PSI
Flow GPM
1500
2000
2500
0
3000
Pressure PSI
Flow GPM
Amps
Amps
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
DC POWER UNIT
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Specials
Delta Power packages designed to meet a variety of applications
Delta Power Packages combine a variety of hydraulic pumps, electric motors, special tanks and JIC style reservoirs in
pre-engineered package to provide maximum efficiency and dependability in most any application where specials are
derived from standard size packages are needed. They deliver from 2.4 GPM at 1600 PSI to 29 GPM at 2000 PSI. The
key to their versatility lies in their CW, 3 through 20 HP TEFC motors with NEMA C face design with reservoirs up to
120 gallon JIC style reservoirs. Each is selected and balanced to perform best with the others. Combined with precisely
machined pump-motor connecting brackets to assure positive shaft alignment and quiet operation, Delta power packages
deliver performance that you can depend on in your system.
Quality at its best
Delta Power quality comes from experience and dedication to accurate, meaningful design, quality materials and
manufacturing excellence to the smallest detail. All to provide our customers with the assurance that they will get
products they and their customers can rely on.
Plus design assistance
We are willing to share our experience in any way it can be useful to you including help in custom circuit design
incorporating Delta Power products (valve, pumps, motors and power packages). Call on Delta Power for assistance in
selecting circuit components for your requirements. Well respond.
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Page 82
ACCESSORIES
INDEX
Description
Page
85
DO3 Valves
Reservoirs
87
89
91
Pressure Switch
93
94
95
96
97
99
101
103
105
107
109
111
113
115
117
119
121
123
125
127
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Page 84
ACCESSORIES
DO3 Valves
Specifications
Spool Configuration Graphic Symbol
SA
A B
Description
25 GPM
5000 PSI
12.5 GPM
5000 PSI
15 GPM
5000 PSI
12.5 GPM
3500 PSI
SB
CC3
A B
SB
CO3
P T
SA
A B
SB
CM3
P T
SA
A B
SB
CT3
Ordering Codes
C
C
C
C
C
O
M
T
A
A
B
B
12
24
11
22
Voltage (12=12VDC, 24=24VDC, 11=110VAC, 22=220VAC)
Termination (A=AC Conduit Box, B= DC din43650)
Spool Configuration (C=Closed Ctr, O= Open Ctr, M=Motor Spool, T=Tandem Ctr.)
DO3 Cetop
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
ACCESSORIES
Drawings
Performance Data
18.9
37.9
350
56.8
6
75.7
94.6
2
113.6
24.1
Pressure PSI
17.2
250
3
200
13.8
10.3
150
4
100
6.9
50
3.4
0.0
0.0
5.0
10.0
15.0
20.0
25.0
Pressure Bar
20.7
300
30.0
Flow GPM
PA
1
2
2
6
PB
1
2
2
6
AT
1
2
1
5
BT
1
2
2
5
PT
1
3
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
ACCESSORIES
Reservoirs
All standard Delta Power Company power packages include a choice of
reservoirs, from the smallest non JIC 10 gallon size to the ruggedly constructed
20 through 120 gallon JIC style reservoirs. All 20 through 120 gallon JIC
reservoirs have 40 micron filter breather, sight level-temperature gauge, tank
baffle, 100 mesh suction strainers, 1 NPTF return line, single-bolt clean out
covers at each end easy access drain plug. Generally, the 10 gallon reservoir is
used with no larger than the 5 HP motor and the 20 gallon reservoir is used with
no larger than a 7 HP motor.
Specifications
Tank Capacity
10 Gallon 20 Gallon 30 Gallon 40 Gallon 60 Gallon 80 Gallon 100 Gallon 120 Gallon
Model Number*
T10
T20
T30
T40
T60
T80
T100
T120
*Tank model number are added to the pump/motor combination model numbers in the CW specifications charts
to complete the total power packaged model number. For example: CW23+3504+T30
Dimensions
A
B
C
T10
23.3
14.5
8.5
T20
30.0
18.0
19.0
T30
36.0
24.0
19.4
Resevoir Model
T40
T60
36.0
48.0
24.0
27.0
21.0
20.5
T80
60.0
27.0
21.5
T100
60.0
27.0
23.5
T120
60.0
30.0
27.0
Accessories/Options
Relief valve
Pressure gauge and shut-off
Directional control valves and cartridge valves, manifolded
Low level liquid switch
Return line filter
As a special service to satisfy our customers needs Delta Power Company will also install as part of the power package
other components provided by our customers.
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
Page 88
PRESSURE CONTROLS
OPERATION
The SJ-RVR blocks flow from (2) to (1) until sufficient pressure is present at (2) to force the pilot stage off its
seat, allowing the main stage spool to shift, opening (2) to (1).
The relief flow path is from (2) to (1). Reverse flow, from (1) to (2), occurs when the pressure at (1) is at
least 30 PSI (2.1bar) higher then at port (2).
The Cartridge offers smooth transition in response to load changes in common hydraulic circuits.
FEATURES
Hardened parts for long life.
Industry common cavity.
HYDRAULIC SYMBOL
VALVE SPECIFICATIONS
Nominal Flow
Rated Operating Pressure
Viscosity Range
Filtration
Media Operating
Temperature Range
Weight
Operating Fluid Media
Cartridge Torque
Requirements
Cavity
Cavity Form Tool (Finishing)
Seal Kit
PERFORMANCE
Actual Test Data (Cartridge Only)
Standard Body
25
50
75
100
125
100
1000
50
500
1500
150
2000
10
15
20
25
25
Port 2 to 1
SUPER 2W
40500017
21191400
50
75
100
125
150
2000
1500
100
1000
50
500
0
0
30
10
15
20
25
30
35
Flow (GPM)
Flow (GPM)
Port 2 to 1
0
5
2500
2500
Undercut Body
Flow (LPM)
Flow (LPM)
0
Port 2 to 1
Port 1 to 2
Port 2 to 1
Port 1 to 2
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
SJ-RVR
OPTIONS
Buna Standard
Viton Standard
Buna, Knob
Viton, Knob
Buna, Internal Adjust
Viton, Internal Adjust
Buna, Tamper Proof
Viton, Tamper Proof
00
V0
0K
VK
0I
VI
0T
VT
Blank
N
S
BODIES
Without Body
3/4 NPTF Ports
#12 SAE Ports
3500
PRESSURE SETTING
500 - 3500 PSI
Example
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
PRESSURE CONTROLS
OPERATION
The DE-RWP blocks flow from (2) to (1) until sufficient pressure is present at (2) to force the pilot stage
open, allowing the main stage to shift, opening (2) to (1).
FEATURES
HYDRAULIC SYMBOL
PERFORMANCE
Actual Test Data (Cartridge Only)
VALVE SPECIFICATIONS
Flow (LPM)
0
25
50
75
3000
2500
150
2000
1500
100
1000
50
500
0
200
Nominal Flow
Rated Operating Pressure
Viscosity Range
Filtration
Media Operating
Temperature Range
Weight
Operating Fluid Media
Cartridge Torque
Requirements
Cavity
Cavity Form Tool (Finishing)
Seal Kit
0
0
10
15
20
Flow (GPM)
Port 2 to 1
Port 2 to 1
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-RWP
OPTIONS
Buna Standard
Viton Standard
Buna, Knob
Viton, Knob
Internally Adj. Buna
Internally Adj. Viton
Tamper Proof Buna
Tamper Proof Viton
00
V0
0K
VK
0I
VI
0T
VT
Blank
N
S
4000
BODIES
Without Body
3/8 NPTF Ports
#8 SAE Ports
PRESSURE RANGE/SETTING
1000 4000 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 500 PSI
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
ACCESSORIES
Pressure Switch
Model
Range
PS1500 150-1500 PSI Adjustable
PS3000 500-3000 PSI Adjustable
This compact, rugged pressure switch is designed to meet todays need for an inexpensive, yet dependable control.
Although housed in an oil-tight, aluminum body, the assembly weighs only 1 lbs. 4 oz. and can be easily included into new
or existing circuitry.
Micro Switch Electrical Data UL and CSA Listed:
15 Amps and HP, 125 or 250 VAC
Amp, 125VDC
Amp, 250 VDC
5 Amps, 12 VAC L
Features Include:
A micro switch rated for 2 million cycles
A specially designed actuator consisting of a dampened piston and positive stop striker plate
Externally adjustable pressure range
Conduit connector
NPTF male pipe thread
Common, normally open, and normally closed terminals
Gasket, removable cover for ease of wire assembly
Pressure reset characteristics: 250-350 PSI differential
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
ACCESSORIES
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
ACCESSORIES
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
ACCESSORIES
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPERATION
The MS-POC allows flow to pass from (V) to (C) and blocks flow from (C) to (V). When pilot pressure is
applied to pilot port the valve allows flow from (C) to (V).
The valve has a 6.7:1 pilot ratio, so at least .149 of the load pressure is required at the (PILOT) port to open
the flow passage to allow flow from ports (C).
The check is spring-biased at 50 psi (3.4 bar) to assure holding in static or no-load conditions.
FEATURES
TYPICAL SCHEMATIC
HYDRAULIC SYMBOL
VALVE SPECIFICATIONS
Nominal Flow
Rated Operating Pressure
Typical Internal Leakage
(150 SSU)
Viscosity Range
Filtration
Pilot Ratio
Media Operating
Temperature Range
Weight
Operating Fluid Media
Cartridge Torque
Requirements
Cartridge Crack Pressure
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
DIMENSIONS
ORDERING INFORMATION
MS-POC
OPTIONS
Buna Standard
Viton Standard
B
V
N
S
BODIES
1/4 NPTF Ports
#4 SAE Ports
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPERATION
The DS-POC allows flow to pass from (V) to (C) and blocks flow from (C) to (V). When pilot pressure is
applied to pilot port the valve allows flow from (C) to (V).
The valve has a 4:1 pilot ratio, so at least .250 of the load pressure is required at the (PILOT) port to open
the flow passage to allow flow from ports (C).
The check is spring-biased at 90 psi (6.2 bar) to assure holding in static or no-load conditions.
FEATURES
TYPICAL SCHEMATIC
HYDRAULIC SYMBOL
VALVE SPECIFICATIONS
Nominal Flow
Rated Operating Pressure
Typical Internal Leakage
(150 SSU)
Viscosity Range
Filtration
Pilot Ratio
Media Operating
Temperature Range
Weight
Operating Fluid Media
Cartridge Torque
Requirements
Cartridge Crack Pressure
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
DIMENSIONS
ORDERING INFORMATION
DS-POC
OPTIONS
Buna Standard
Viton Standard
B
V
N
S
BODIES
3/8 NPTF Ports
#8 SAE Ports
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPERATION
The DD-POC allows flow to pass from (V1) to (C1) and (V2) to (C2). The valve blocks flow from (C1) to
(V1) and from (C2) to (V2). Blocked flow is released when pilot pressure is applied to port opposite
valve (V1) and/or port (V2) accordingly.
The valve has a 4:1 pilot ratio, so at least .250 of the load pressure at port (C1) or (C2) is required at
the pilot lines (ports (V2) or (V1) respectively to open the flow passage to allow flow from ports (C1) or
(C2) respectively.
The check is spring-biased at 90 psi (6.2 bar) to assure holding in static or no-load conditions.
FEATURES
TYPICAL SCHEMATIC
HYDRAULIC SYMBOL
VALVE SPECIFICATIONS
Nominal Flow
Rated Operating Pressure
Typical Internal Leakage
(150 SSU)
Viscosity Range
Filtration
Pilot Ratio
Media Operating
Temperature Range
Weight
Operating Fluid Media
Cartridge Torque
Requirements
Cartridge Crack Pressure
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
DIMENSIONS
ORDERING INFORMATION
DD-POC
OPTIONS
Buna Standard
Viton Standard
B
V
N
S
BODIES
3/8 NPTF Ports
#8 SAE Ports
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPERATION
See options chart for specific operation
VALVE SPECIFICATIONS
Nominal Flow
Rated Operating Pressure
Viscosity Range
Filtration
Media Operating
Temperature Range
Operating Fluid Media
Cartridge Size
Cartridge Torque
Requirements
Coil Torque Nut
Requirements
DIMENSIONS
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPTIONS CHART
ORDERING INFORMATION
-
CIRCUITS
AA
AB
AC
AD
AE
AF
AG
AH
OPTIONS
Buna Standard
Viton Standard
Manual Override
D COIL TERMINATION
(All DC Except as Noted)
DL
DT
ML
PL
WL
SS
DS
Double Lead
Deutsch on Leads DT04-2P
Metri-Pack on Leads
Packard on Leads
Weatherpack on Leads
Single Spade
Double Spade
HC
CL
DI
IA
ID
IJ
IM
00
V0
0M
06
12
24
36
48
25
11
22
44
VOLTAGE
6 VDC
12 VDC
24 VDC
36 VDC
48 VDC
25 VAC
120 VAC
220 VAC
440 VAC
01
02
04
08
01
02
04
08
VALVE 2
FLOW
.5-1 GPM
1-2 GPM
2-4 GPM
4/8 GPM
FLOW CONTROL
VALVE 1
FLOW
.5-1 GPM
1-2 GPM
2-4 GPM
4-8 GPM
FLOW CONTROL
02
15
30
40
02
15
30
40
PRESSURE
20-500 PSI
200-1500 PSI
1500-3000 PSI
2500-4000 PSI
RELIEF VALVE
PRESSURE
20-500 PSI
200-1500 PSI
1500-3000 PSI
2500-4000 PSI
RELIEF VALVE
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPERATION
See options chart for specific operation
VALVE SPECIFICATIONS
Nominal Flow
Rated Operating Pressure
Viscosity Range
Filtration
Media Operating
Temperature Range
Operating Fluid Media
Cartridge Size
Cartridge Torque
Requirements
Coil Torque Nut
Requirements
DIMENSIONS
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPTIONS CHART
ORDERING INFORMATION
-
CIRCUITS
BA
BB
BC
OPTIONS
Buna Standard
Viton Standard
Manual Override
D COIL TERMINATION
(All DC Except as Noted)
DL
DT
ML
PL
WL
SS
DS
Double Lead
Deutsch on Leads DT04-2P
Metri-Pack on Leads
Packard on Leads
Weatherpack on Leads
Single Spade
Double Spade
HC
CL
DI
IA
ID
IJ
IM
00
V0
0M
06
12
24
36
48
25
11
22
44
VOLTAGE
6 VDC
12 VDC
24 VDC
36 VDC
48 VDC
25 VAC
120 VAC
220 VAC
440 VAC
01
02
04
08
01
02
04
08
VALVE 2
FLOW
.5-1 GPM
1-2 GPM
2-4 GPM
4/8 GPM
FLOW CONTROL
VALVE 1
FLOW
.5-1 GPM
1-2 GPM
2-4 GPM
4-8 GPM
FLOW CONTROL
02
15
30
40
02
15
30
40
PRESSURE
20-500 PSI
200-1500 PSI
1500-3000 PSI
2500-4000 PSI
RELIEF VALVE
PRESSURE
20-500 PSI
200-1500 PSI
1500-3000 PSI
2500-4000 PSI
RELIEF VALVE
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPERATION
See options chart for specific operation
VALVE SPECIFICATIONS
Nominal Flow
Rated Operating Pressure
Viscosity Range
Filtration
Media Operating
Temperature Range
Operating Fluid Media
Cartridge Size
Cartridge Torque
Requirements
Coil Torque Nut
Requirements
DIMENSIONS
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPTIONS CHART
ORDERING INFORMATION
-
CIRCUITS
CA
CB
CC
CD
CE
CF
OPTIONS
Buna Standard
Viton Standard
Manual Override
D COIL TERMINATION
(All DC Except as Noted)
DL
DT
ML
PL
WL
SS
DS
Double Lead
Deutsch on Leads DT04-2P
Metri-Pack on Leads
Packard on Leads
Weatherpack on Leads
Single Spade
Double Spade
HC
CL
DI
IA
ID
IJ
IM
00
V0
0M
06
12
24
36
48
25
11
22
44
VOLTAGE
6 VDC
12 VDC
24 VDC
36 VDC
48 VDC
25 VAC
120 VAC
220 VAC
440 VAC
01
02
04
08
01
02
04
08
VALVE 2
FLOW
.5-1 GPM
1-2 GPM
2-4 GPM
4/8 GPM
FLOW CONTROL
VALVE 1
FLOW
.5-1 GPM
1-2 GPM
2-4 GPM
4-8 GPM
FLOW CONTROL
02
15
30
40
02
15
30
40
PRESSURE
20-500 PSI
200-1500 PSI
1500-3000 PSI
2500-4000 PSI
RELIEF VALVE
PRESSURE
20-500 PSI
200-1500 PSI
1500-3000 PSI
2500-4000 PSI
RELIEF VALVE
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPERATION
See options chart for specific operation
VALVE SPECIFICATIONS
Nominal Flow
Rated Operating Pressure
Viscosity Range
Filtration
Media Operating
Temperature Range
Operating Fluid Media
Cartridge Size
Cartridge Torque
Requirements
Coil Torque Nut
Requirements
DIMENSIONS
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPTIONS CHART
ORDERING INFORMATION
-
CIRCUITS
DA
DB
DC
DD
DE
DF
OPTIONS
Buna Standard
Viton Standard
Manual Override
D COIL TERMINATION
(All DC Except as Noted)
DL
DT
ML
PL
WL
SS
DS
Double Lead
Deutsch on Leads DT04-2P
Metri-Pack on Leads
Packard on Leads
Weatherpack on Leads
Single Spade
Double Spade
HC
CL
DI
IA
ID
IJ
IM
00
V0
0M
06
12
24
36
48
25
11
22
44
VOLTAGE
6 VDC
12 VDC
24 VDC
36 VDC
48 VDC
25 VAC
120 VAC
220 VAC
440 VAC
01
02
04
08
VALVE 1
FLOW
.5-1 GPM
1-2 GPM
2-4 GPM
4-8 GPM
FLOW CONTROL
02
15
30
40
PRESSURE
20-500 PSI
200-1500 PSI
1500-3000 PSI
2500-4000 PSI
RELIEF VALVE
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPERATION
See options chart for specific operation
VALVE SPECIFICATIONS
Nominal Flow
Rated Operating Pressure
Viscosity Range
Filtration
Media Operating
Temperature Range
Operating Fluid Media
Cartridge Size
Cartridge Torque
Requirements
Coil Torque Nut
Requirements
DIMENSIONS
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPTIONS CHART
DUAL SPEED CIRCUI T
VALVE 1
1
S2C
2
S2A
2
NVB
1
VALVE 2
NVB
1
12 GPM NOMINA L
CIRCUIT EA
CIRCUIT EE
12 GPM NOMINA L
A
S2A
2
RVA
CVA
FCA
1
B
8 GPM NOMINA L
CIRCUIT EB
10 GPM NOMINA L
CIRCUIT EF
DUAL SPEED CIRCUI T
A
2
FCA
1
S2H 2
CVA
2
NVA
1
B
8 GPM NOMINA L
7 GPM NOMINA L
CIRCUIT EC
CIRCUIT EG
A
S2C
2
2
FCA
1
8 GPM NOMINA L
CIRCUIT ED
ORDERING INFORMATION
-
CIRCUITS
EA
EB
EC
ED
EE
EF
EG
OPTIONS
Buna Standard
Viton Standard
Manual Override
D COIL TERMINATION
(All DC Except as Noted)
DL
DT
ML
PL
WL
SS
DS
Double Lead
Deutsch on Leads DT04-2P
Metri-Pack on Leads
Packard on Leads
Weatherpack on Leads
Single Spade
Double Spade
HC
CL
DI
IA
ID
IJ
IM
00
V0
0M
06
12
24
36
48
25
11
22
44
VOLTAGE
6 VDC
12 VDC
24 VDC
36 VDC
48 VDC
25 VAC
120 VAC
220 VAC
440 VAC
01
02
04
08
01
02
04
08
VALVE 2
FLOW
.5-1 GPM
1-2 GPM
2-4 GPM
4/8 GPM
FLOW CONTROL
VALVE 1
FLOW
.5-1 GPM
1-2 GPM
2-4 GPM
4-8 GPM
FLOW CONTROL
02
15
30
40
02
15
30
40
PRESSURE
20-500 PSI
200-1500 PSI
1500-3000 PSI
2500-4000 PSI
RELIEF VALVE
PRESSURE
20-500 PSI
200-1500 PSI
1500-3000 PSI
2500-4000 PSI
RELIEF VALVE
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPERATION
See typical schematic for specific operation.
VALVE SPECIFICATIONS
Nominal Flow
Rated Operating Pressure
Viscosity Range
Filtration
Media Operating
Temperature Range
Operating Fluid Media
Cartridge Size
Cartridge Torque
Requirements
DIMENSIONS
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
TYPICAL SCHEMATIC
C1A
C1B
C2A
C2B
PWE
PWE
CVA
CVA
VA
VB
DUAL SEQUENCE VALVE MANIFOLD
AUTOMATICALLY CONTROLS THE
SEQUENCING OF TWO CYLINDERS.
CIRCUIT FA
ORDERING INFORMATION
-
CIRCUITS
FA
OPTIONS
Buna Standard
Viton Standard
04
15
30
00
V0
04
15
30
VALVE 2
PRESSURE
50-425 PSI
400-1500 PSI
1500-3000 PSI
VALVE 1
PRESSURE
50-425
400-1500 PSI
1500-3000 PSI
FOR SPECIAL PRESET VALUES ON VALVES, CONSULT FACTORY
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPERATION
See model options for specific operation (back)
VALVE SPECIFICATIONS
Nominal Flow
Rated Operating Pressure
Viscosity Range
Filtration
Media Operating
Temperature Range
Operating Fluid Media
Cartridge Size
Cartridge Torque
Requirements
Coil Torque Nut
Requirements
DIMENSIONS
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPTIONS CHART
ORDERING INFORMATION
-
CIRCUITS
IA
IB
IC
ID
IE
IF
IG
IH
OPTIONS
Buna Standard
Viton Standard
Manual Override
D COIL TERMINATION
(All DC Except as Noted)
DL
DT
ML
PL
WL
SS
DS
Double Lead
Deutsch on Leads DT04-2P
Metri-Pack on Leads
Packard on Leads
Weatherpack on Leads
Single Spade
Double Spade
HC
CL
DI
IA
ID
IJ
IM
00
V0
0M
06
12
24
36
48
25
11
22
44
VOLTAGE
6 VDC
12 VDC
24 VDC
36 VDC
48 VDC
25 VAC
120 VAC
220 VAC
440 VAC
01
02
04
08
01
02
04
08
VALVE 2
FLOW
.5-1 GPM
1-2 GPM
2-4 GPM
4-8 GPM
FLOW CONTROL
VALVE 1
FLOW
.5-1 GPM
1-2 GPM
2-4 GPM
4-8 GPM
FLOW CONTROL
02
15
30
40
02
15
30
40
PRESSURE
20-500 PSI
200-1500 PSI
1500-3000 PSI
2500-4000 PSI
RELIEF VALVE
PRESSURE
20-500 PSI
200-1500 PSI
1500-3000 PSI
2500-4000 PSI
RELIEF VALVE
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPERATION
See typical schematic for specific operation.
VALVE SPECIFICATIONS
Nominal Flow
Rated Operating Pressure
Viscosity Range
Filtration
Media Operating
Temperature Range
Operating Fluid Media
Cartridge Size
Cartridge Torque
Requirements
DIMENSIONS
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
TYPICAL SCHEMATIC
DUAL COUNTERBALANCE
C1
C2
CB2
CB1
V1
V2
CIRCUIT LA
ORDERING INFORMATION
CIRCUITS
LA
OPTIONS
Buna Standard
00
15
40
VALVE 2
PRESSURE RANGE
400-1500 PSI
1500-4000 PSI
15
40
VALVE 1
PRESSURE RANGE
400-1500 PSI
1500-4000 PSI
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPERATION
See options chart for specific operation (back)
VALVE SPECIFICATIONS
Nominal Flow
Rated Operating Pressure
Viscosity Range
Filtration
Media Operating
Temperature Range
Operating Fluid Media
Cartridge Size
Cartridge Torque
Requirements
Coil Torque Nut
Requirements
DIMENSIONS
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPTIONS CHART
ORDERING INFORMATION
-
CIRCUITS
PA
PB
PC
PD
OPTIONS
Buna Standard
Viton Standard
Manual Override
D COIL TERMINATION
(All DC Except as Noted)
DL
DT
ML
PL
WL
SS
DS
Double Lead
Deutsch on Leads DT04-2P
Metri-Pack on Leads
Packard on Leads
Weatherpack on Leads
Single Spade
Double Spade
HC
CL
DI
IA
ID
IJ
IM
00
V0
0M
06
12
24
36
48
25
11
22
44
01
02
04
08
VOLTAGE
6 VDC
12 VDC
24 VDC
36 VDC
48 VDC
25 VAC
120 VAC
220 VAC
440 VAC
01
02
04
08
VALVE 2
FLOW
.5-1 GPM
07
1-2 GPM
30
2-4 GPM
40
4-8 GPM
FLOW CONTROL
VALVE 1
FLOW
.5-1 GPM
07
1-2 GPM
30
2-4 GPM
40
4-8 GPM
FLOW CONTROL
PRESSURE
100-700 PSI
100-3000 PSI
3000-4000 PSI
RELIEF VALVE
PRESSURE
100-700 PSI
100-3000 PSI
3000-4000 PSI
RELIEF VALVE
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPERATION
See options chart for specific operation
VALVE SPECIFICATIONS
Nominal Flow
Rated Operating Pressure
Viscosity Range
Filtration
Media Operating
Temperature Range
Operating Fluid Media
Cartridge Size
Cartridge Torque
Requirements
Coil Torque Nut
Requirements
DIMENSIONS
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPTIONS CHART
C2
C1
C1
C2
VALVE 1
VALVE 2
C1
V1
V2
RVA
RVA
V1
V1
10 GPM NOMINAL
C1
C2
V1
V2
10 GPM NOMINAL
CIRCUIT SA
C1
C2
V2
RVA
2
C2
1
V2
S2C
CIRCUIT SB
MOWER BREAKAWAY
1
2
C1
V1
V2
C2
PSD
V1
10 GPM NOMINAL
1
PSD
V2
CIRCUIT SC
ORDERING INFORMATION
-
CIRCUITS
SA
SB
SC
OPTIONS
Buna Standard
Viton Standard
Double Lead
Deutsch on Leads DT04-2P
Metri-Pack on Leads
Packard on Leads
Weatherpack on Leads
Single Spade
Double Spade
00
V0
06
12
24
36
48
25
11
22
44
D COIL TERMINATION
(All DC Except as Noted)
DL
DT
ML
PL
WL
SS
DS
HC
CL
DI
IA
ID
IJ
IM
Approximate Coil Weight: .74 lbs (.33 kg.)
VOLTAGE
6 VDC
12 VDC
24 VDC
36 VDC
48 VDC
25 VAC
120 VAC
220 VAC
440 VAC
01
02
04
08
01
02
04
08
VALVE 2
FLOW
.5-1 GPM
1-2 GPM
2-4 GPM
4/8 GPM
FLOW CONTROL
VALVE 1
FLOW
.5-1 GPM
1-2 GPM
2-4 GPM
4-8 GPM
FLOW CONTROL
15
30
40
15
30
40
PRESSURE
150-1500PSI
1500-3000 PSI
2500-4000 PSI
RELIEF VALVE
PRESSURE
150-1500 PSI
1500-3000 PSI
2500-4000 PSI
RELIEF VALVE
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPERATION
The IM-CVF-11 allows flow to pass between (1) and (2). When oil velocity from (1) to (2) exceeds the flow
setting, the valve shifts and blocks flow from (1) to (2).
FEATURES
HYDRAULIC SYMBOL
PERFORMANCE
VALVE SPECIFICATIONS
Nominal Flow Max.
Rated Operating Pressure
Typical Internal Leakage
(150 SSU)
Viscosity Range
Filtration
Media Operating
Temperature Range
Weight
Operating Fluid Media
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
DIMENSIONS
ORDERING INFORMATION
IM-CVF
- 11
01.0
02.0
03.0
04.0
05.0
06.0
FLOW SETTINGS
1 GPM
2 GPM
3 GPM
4 GPM
5 GPM
6 GPM
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPERATION
The IM-CVF-13 allows flow to pass between (1) and (2). When oil velocity from (1) to (2) exceeds the flow
setting, the valve shifts and blocks flow from (1) to (2).
FEATURES
HYDRAULIC SYMBOL
PERFORMANCE
VALVE SPECIFICATIONS
Nominal Flow Max.
Rated Operating Pressure
Typical Internal Leakage
(150 SSU)
Viscosity Range
Filtration
Media Operating
Temperature Range
Weight
Operating Fluid Media
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
DIMENSIONS
ORDERING INFORMATION
IM-CVF
- 13
01.0
02.0
03.0
04.0
05.0
06.0
FLOW SETTINGS
1 GPM
2 GPM
3 GPM
4 GPM
5 GPM
6 GPM
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
OPERATION
The IM-CSB allows flow from the higher pressure of (1) or (3) to (2).
The valve is commonly used as a load sense to direct oil from the pressure side of a
bidirectional hydraulic motor to a pressure released hydraulic brake.
FEATURES
HYDRAULIC SYMBOL
PERFORMANCE
VALVE SPECIFICATIONS
Nominal Flow
Rated Operating Pressure
Typical Internal Leakage
(150 SSU)
Viscosity Range
Filtration
Media Operating
Temperature Range
Weight
Operating Fluid Media
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
DIMENSIONS
ORDERING INFORMATION
IM-CSB
Buna Standard
Viton Standard
00
V0
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
MISCELLANEOUS
INDEX
Description
Key to Power Unit Details
Page
130
Pump List
131
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
MISCELLANEOUS
Item
1
2
3
4
5
6
11
12
13
Part No.
3340XXXX
3311XXXX
3364XXXX
379XXXXX
5012XXXX
2112XXXX
2113XXXX
3320XXXX
3330XXXX
14
15
21
22
23
24
25
26
27
28
29
30
31
3313XXXX
6030XXXX
3350XXXX
3350XXXX
3355XXXX
6010XXXX
6210XXXX
3180XXXX
6140XXXX
3250XXXX
308XXXXX
3356XXXX
Description
Gear Case
Drive Shaft
Gear
Coupling
Reservoir
Gasket
Seal Kit
Drive Plate Assembly
End Plate Assembly
Ball Check R.V. Assembly
(Ball, Spring, & Guide)
Idler Shaft Assembly
Shaft Seal (In Item #11)
Gear Pin
Ball Pin
Retaining Ring
Body Seal (In Item #11)
Breather
Strainer
Roller Bearing
Drive Key
Motor
Snap Ring
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com
MISCELLANEOUS
Pump List
Seal Kit
A1, 2, 4, 6, 8
A 21, 23, 25, 27
B 1, 2, 4, 6, 8
C 1, 2, 4, 6, 8
C 21, 23, 25, 27
C 41, 43, 45, 47, 49
D 1, 2, 4, 6, 8
D 21, 23, 25, 27
D 41, 43, 45, 47, 49
DM 1, 2, 4, 6, 8
DM 21, 23, 25, 27
DM 41, 43, 45, 47, 49
A, B, C, D, DM 1
A, B, C, D, DM 2
A, B, C, D, DM 4
A, B, C, D, DM 6
A, B, C, D, DM 8
A, C, D, DM 21
A, C, D, DM 23
A, C, D, DM 25
A, C, D, DM 27
C, D, DM 41
C, D, DM 43
C, D, DM 45
C, D, DM 47
C, D, DM 49
Buna
21220001
33300002
21120002
21120001
21120004
21120006
21120003
21120005
21120007
21120022
21120023
21120024
Gear
Case
1
33400001
33400002
33400004
33400006
33400008
33400021
33400023
33400025
33400027
33400041
33400043
33400045
33400047
33400049
11
Viton
33550001
33550000
33550001
21130001
21130004
21130006
N/A
21130006
21130007
21160001
21160002
21160003
Drive Plate
Assy.
12
33200001
33200005
33200002
33200001
33200006
33200009
33200003
33200007
33200010
33200004
33200008
33200011
33200005
33200002
33550000
33550000
33550001
33550002
33550000
33550001
33550002
33550000
33550001
33550002
Outboard
Bearing
28
N/A
32500002
32500003
32500004
32500002
32500003
32500004
Drive Shaft
2
A, B1 33110001
A, B2 33110002
A. B4 33110004
A, B6 33110006
A, B8 33110008
A21 33113021
A23 33113023
A25 33113025
A27 33113027
N/A
C1 33111001
C2 33111002
C4 33111004
C6 33111006
C8 33111008
C21 33114021
C23 33114023
C25 33114025
C27 33114027
C41 33118041
C43 33118043
C45 33118045
C47 33118047
C49 33118049
D, DM1 33112001
D, DM2 33112002
D, DM4 33112004
D, DM6 33112006
D, DM8 33112008
D21 33115021
D23 33115023
D25 33115025
D27 33115027
D41 33119041
D43 33119043
D45 33119045
D47 33119047
D49 33119049
N/A
33560000
33560001
33560002
N/A
33560000 33570000
33560001 33570001
33560002 33570002
Gear
3
N/A
DM21 33116021
DM23 33116023
DM25 33116025
DM27 33116027
DM41 3319141
DM43 3319143
DM45 3319145
DM47 3319147
N/A
33640001
33640002
33640004
33640006
33640008
33640021
33640023
33640025
33640027
33640041
33640043
33640045
33640047
33640049
Idler Shaft
Assy.
15
33130001
33130002
33130004
33130006
33130008
33130021
33130023
33130025
33130027
33130041
33130043
33130045
33130047
33130049
Gear Pin
22
33500001
33500001
33500004
33500006
33500008
33500021
33500023
33500027
33500027
33500041
33500043
33500045
33500045
33500049
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
E-mail: delta@delta-power.com