Interchange™ Comm Control Module, MX5 Series: Installation and Operations Manual
Interchange™ Comm Control Module, MX5 Series: Installation and Operations Manual
Interchange™ Comm Control Module, MX5 Series: Installation and Operations Manual
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our
specifications and designs at any time. The latest version of this manual can be found at www.fwmurphy.com.
Warranty - A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of
the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm.
Table of Contents
Murphy Interchange Comm Control Module Series ........................................................... 1
MX5 Digital Inputs/Outputs, Analog Inputs, MPU .......................................................1
MX5-A Digital Inputs/Outputs , Analog Inputs/Outputs, MPU ....................................1
MX5-D Digital Inputs/Outputs , Analog Inputs, MPU ..................................................1
Product Dimensions and Mounting ..............................................................................2
Accessories ..................................................................................................................2
Specifications ...............................................................................................................2
MX5 Installation Instructions ........................................................................................2
Installation Diagram .....................................................................................................3
MX5 Jumper Configuration...........................................................................................5
Communications ..................................................................................................................... 7
MX5 Expansion Module - Modbus RTU Description ....................................................8
Section 50
11-06-09
00-02-0628
-1-
Accessories
MX5 Plug Kit (00030868) Printed Terminal Plugs for MX5 Expansion I/O Module
Specifications
Operating Temperature: -40 to +85C (185F)
Storage Temperature: -40 to +85C (185F)
Power Input Voltage: 10 to 32 VDC (30W max)
Section 50
11-06-09
00-02-0628
-2-
Installation Diagram
Section 50
11-06-09
00-02-0628
-3-
Section 50
11-06-08
00-02-0628
-4-
LK2 and LK4: This jumper provides a termination resistor for the CAN
communication chain. This jumper must be in place only when the I/O module is the
last in the communication chain. See control panel drawings for designation. The
cover of the MX5 must be removed to access this jumper link (LK2/LK4). CAN 2 is
not used. CAN 1 is used for data link for communication chain.
(Refer to the Communications chapter in this document)
Section 50
11-06-08
00-02-0628
-5-
Section 50
11-06-08
00-02-0628
-6-
Communications
Physical Layer: The MX5 module features one asynchronous RS232 serial communication
port, one asynchronous RS485 serial communication port, and one CANBUS 2.0B proprietary
communication port.
RS232 Interconnect: The module is equipped with screw terminals called Port 1. This
connection is typically used to poll the information for a specific module using twisted shielded
cable suitable for RS232 networks. The simplest form of these networks are 3-wire, halfduplex, using RX terminal 57, TX terminal 55, and GND terminal 59. The TX terminal is the
TRANSMIT DATA signal, the RX terminal is the RECEIVE DATA signal, and the GND is the
COMMON GROUND signal for the communication line. These signal lines will take turns
transmitting and receiving depending on the device using the RS232 network at any given
instant. The MX5 also provides connections for CTS and DTR signals if required for 5 wire
RS232 connections.
RS485 Interconnect: The module is equipped with screw terminals called Port 2. This
connection is typically used to poll the information for a specific module using twisted shielded
pair cable with 120 ohm impedance suitable for RS485 networks. These networks are 2-wire,
half-duplex, and feature an A terminal 61, B terminal 62, and SHD terminal 63 shielded
ground connection. The A terminal is the + or non-inverting signal, and the B terminal is the
or inverting signal. These signal lines will take turns transmitting and receiving depending on
the device using the RS485 network at any given instant.
Baud Rate: 9600 fixed (RS232/RS485)
Protocol: Modbus RTU. This is a binary communication protocol. All data will be contained in
unsigned 16-bit Modbus Holding Registers (addressed starting at 40001). Following the
Modbus RTU specification, the Most Significant Byte in a 16-bit word is broadcast first,
followed by the Least Significant Byte.
Refer to the Modbus RTU map provided in this manual for a detailed mapping of the available
data and data scaling.
CANBUS 2.0 B Interconnect: The module is equipped with screw terminals called Port 3.
This connection is typically used to provide the interconnections between the main control
module which polls the information for a specific module using twisted shielded pair cable with
120 ohm impedance suitable for CAN networks. This network protocol is proprietary
CANBUS, and features a HI(CAN H) terminal 64, LO(CAN L) terminal 65 connection, and
SHD terminal 66 shielded ground connection.
Section 50
11-06-09
00-02-0628
-7-
Description
Read/
Write
Range
FactoryUse
40021
Digitalinputs116
0 - 65535
40022
Digitalinputs1724
0 - 255
40023
Rawcountsystemvoltage
0 - 1023
A/D count
40024
Rawcountanaloginput1
0 - 1023
A/D count
40025
Rawcountanaloginput2
0 - 1023
A/D count
40026
Rawcountanaloginput3
0 - 1023
A/D count
40027
Rawcountanaloginput4
0 - 1023
A/D count
40028
Rawcountanaloginput5
0 - 1023
A/D count
40029
Rawcountanaloginput6
0 - 1023
A/D count
Section 50
11-06-08
Definitions
Data Units
00-02-0628
-8-
Modbus
Register
Description
Read/
Write
Range
Data Units
40030
Rawcountanaloginput7
0 - 1023
A/D count
40031
Rawcountanaloginput8
0 - 1023
A/D count
40032
Rawcountanaloginput9
0 - 1023
A/D count
40033
Rawcountanaloginput10
0 - 1023
A/D count
40034
40035
40036
40037
40038
40039
40040
40046
40047
40048
40049
40050
Rawcountanaloginput11
Rawcountanaloginput12
Rawcountanaloginput13
Rawcountanaloginput14
Frequencyinput(hertz)
ModbusCTS
R
R
R
R
R
R
0 - 4095
0 - 4095
0 - 4095
0 - 4095
30 10,000
0-1
A/D count
A/D count
A/D count
A/D count
Hz
state of signal
FactoryUse
Definitions
0 = 0.0 VDC, 1023 =
5 VDC
0 = 0.0 VDC, 1023 =
5 VDC
0 = 0.0 VDC, 1023 =
5 VDC
0 = 0.0 VDC, 1023 =
5 VDC
FutureUse
FutureUse
FutureUse
FutureUse
Analogoutput1signal
Analogoutput2signal
Analogoutput3signal
Analogoutput4signal
R/W
R/W
R/W
R/W
0 - 65535
0 - 65535
0 - 65535
0 - 65535
40051
Analogoutputs1&2type
R/W
0-3
40052
Analogoutputs3&4type
R/W
0-3
40053
40054
40055
40056
40057
40058
40059
RTCTimeseconds
RTCTimeminutes
RTCTimehours
RTCDayofweek
RTCDateday
RTCDatemonth
RTCDateyear
R
R/W
R/W
R/W
R/W
R/W
R/W
0 - 59
0 - 59
0 - 23
`1 - 7
`1 - 31
`1 - 12
2000 - 3000
40060
Clocksetenable
R/W
0-1
Dependent on 40051
Dependent on 40051
Dependent on 40052
Dependent on 40052
0 = not used,
1 = 4 to 20 mA,
2 = 0 to 20 mA,
3 = 0 to 24 mA
0 = not used,
1 = 4 to 20 mA,
2 = 0 to 20 mA,
3 = 0 to 24 mA
40061
Digitaloutputs116
R/W
0 - 65535
40062
ModbusDTR
R/W
0-1
40063
Digitaloutput116statusonpower
up
R/W
0 - 65535
40064
Digitaloutput116statusoncomm.
failure
R/W
0 - 65535
R/W
R/W
R/W
R/W
0 - 65535
0 - 65535
0 - 65535
0 - 65535
upper8bitsarefor
optionaldigitaloutput
daughtercard
upper8bitsarefor
optionaldigitaloutput
daughtercard
upper8bitsarefor
optionaldigitaloutput
daughtercard
R/W
0 - 65535
R/W
0 - 65535
40065
40066
40067
40068
40069
40070
Analogoutput1statusonpowerup
Analogoutput2statusonpowerup
Analogoutput3statusonpowerup
Analogoutput4statusonpowerup
Analogoutput1statusoncomm.
failure
Analogoutput2statusoncomm.
failure
Section 50
11-06-08
00-02-0628
-9-
Modbus
Register
40071
40072
40073
40074
40077
Description
Analogoutput3statusoncomm.
failure
Analogoutput4statusoncomm.
failure
Communicationtimeout
FactoryUse
Read/
Write
Range
R/W
0 - 65535
R/W
0 - 65535
R/W
0 65535
Definitions
Data Units
time in seconds
Section 50
11-06-08
00-02-0628
- 10 -
Section 50
11-06-08
00-02-0628
- 11 -
Section 50
11-06-08
00-02-0628
- 12 -
Section 50
11-06-08
00-02-0628
- 13 -
Section 50
11-06-08
00-02-0628
- 14 -
MURPHY and the Murphy logo are registered and/or common law trademarks of Murphy Industries, Inc. This
document, including textual matter and illustrations, is copyright protected by Murphy Industries, Inc., with all
rights reserved. (c) 2009 Murphy Industries, Inc. Other third party product or trade names referenced herein are
the property of their respective owners and are used for identification purposes only.
Section 50
11-06-08
00-02-0628
- 15 -